Plan Review Details - Permit 05120638
Plan Review Stops For Permit 05120638
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-09-28 Cont ID  
Sent By lmartine Date 2007-09-28 Time 08:18 Rev Time 0.00
Received By lmartine Date 2007-09-28 Time 08:18 Sent To  
Notes
2007-09-28 08:18:58ROOF TILE REVISION APPROVED

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-06 Cont ID  
Sent By alange Date 2006-07-06 Time 13:16 Rev Time 1.75
Received By alange Date 2006-07-06 Time 11:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-18 Cont ID  
Sent By alange Date 2006-05-18 Time 08:05 Rev Time 1.75
Received By alange Date 2006-05-18 Time 08:05 Sent To  
Notes
2006-05-18 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 4. W P B ADMINISTRTIVE CODE 106.3.3*
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.
  
 6. BASED ON ICC BUIDLING VALUATION DATA
 THE PERMIT VALUATION HAS BEN REVISED TO
 $146,815.00. ADDITIONAL PERMIT FEES WILL
 BE DUE.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-07-21 Cont ID  
Sent By dpalmer Date 2006-07-21 Time 12:15 Rev Time 0.00
Received By dpalmer Date 2006-07-21 Time 11:55 Sent To PC
Notes
2006-07-21 00:00:00REDLINED **
  
 PLACEMENT OF SD'S PER NFPA-72
 11.5.1.1,11.8.3
 CONDUIT FROM METER TO PANEL IS TO BE IN
 SLAB OR MAIN MUST BE ADDED W/ OCP ON THE
 OUTSIDE. 230.6,230.70

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-07-13 Cont ID  
Sent By btrobaug Date 2006-07-13 Time 11:58 Rev Time 1.00
Received By btrobaug Date 2006-07-13 Time 08:52 Sent To PC
Notes
2006-07-13 00:00:00 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} 230.70 GENERAL.
 MEANS SHALL BE PROVIDED TO DISCONNECT
 ALL CONDUCTORS IN A BUILDING OR OTHER
 STRUCTURE FROM THE SERVICE-ENTRANCE
 CONDUCTORS.
 230.70(A)(1)-READILY ACCESSIBLE
 LOCATION. THE SERVICE DISCONNECTING
 MEANS SHALL BE INSTALLED AT A READILY
 ACCESSIBLE LOCATION EITHER OUTSIDE OF A
 BUILDING OR STRUCTURE OR INSIDE NEAREST
 THE POINT OF ENTRANCE OF THE SERVICE
 CONDUCTORS.
  
 THE NOTE ABOUT "RUNNING OVERHEAD IN
 TRUSSES" ON THE RISER DICTATES THAT A
 MAIN DISCONNECT BE LOCATED OUTSIDE,
 PREFERABLY BY THE METER. PLEASE SHOW
 SAME ON RISER AND LOCATE THE MAIN ON THE
 PLAN. THIS IS THE SAME COMMENT THAT WAS
 MADE IN THE FIRST REVIEW.
 THERE WAS A DISCONNECT ADDED TO THE
 6,8,06 PLAN, BUT REMOVED FROM THE PLAN
 SUBMITTED 7/13/06.
  
 2} THE RECEPTACLE SPACING IN THE MASTER
 SUITE, GREAT ROOM, BEDROOM #3, AND THE
 KITCHEN DOES NOT COMPLY WITH
 210.52(A)(1), 210.52(A)(2), AND
 210.52(C)(1). THESE RECEPTACLES WERE ON
 THE THE PLANS DATED JUNE 8, 2006, BUT
 HAVE BEEN REMOVED FROM THE PLANS
 SUBMITTED ON 7/13/06, DATED JULY 7TH,
 2006 BY THE STRUCTURAL ENGINEER. PLEASE
 PUT THEM BACK ON AND RESUBMIT.
  
 THE PERSON TAKING RESPONSIBILITY FOR THE
 DESIGN MUST PRINT AND SIGN THEIR NAME TO
 SAME PER 106.3.4.2. THE ENGINEER SHOULD
 TAKE HIS TITLE BLOCK OF THIS SHEET, AND
 DO NOT SIGN IF HE'S NOT THE DESIGNER AS
 INDICATED BY THE "STRUCTURAL ONLY"
 DISCLAIMER ON THE SEAL.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL,
 I HAVE RETAINED THE ELECTRICAL SHEET
 FROM ONE SET OF THE PLANS.
  
 WILLIAM R. TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561) 805-6718
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-23 Cont ID  
Sent By dpalmer Date 2006-06-23 Time 19:01 Rev Time 0.00
Received By dpalmer Date 2006-06-23 Time 18:40 Sent To B
Notes
2006-06-23 00:00:00 
 ****UNSAT ***
  
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 2) NOTE: PLEASE SEE A NEW MAIN
 DISCONNECT IS BEING INDICATED, HOWEVER
 IS THIS A NETER/MAIN COMBO? IF NOT,
 PLEASE INDICATE THE MAIN AT THE METER
 LOCATION ON PLANS.
 ** PLEASE SEE PANEL INSIDE HOUSE IS
 STILL BE SHOWN AS A MCB PANEL WHICH IS
 PERMITTED, HOWEVER NOT REQUIRED NOW THAT
 THERE IS MAIN OUTSIDE. IF SHOWN ON
 PLANS, THEN A MCB WILL BE REQ'D.
  
 3) NOTE: PLEASE SEE MISSING RECEPT FOR
 2' FO WALL SPACE IN MASTER SUITE.
 210.52
  
 4) NOTE: PLEASE SEE SD OUTSIDE BEDRM #2
 AND #3 MUST BE 5'FROM RAG, AND 3' FROM
 BATH RM DOOR. PLEASE SEE MECH PLANS
 INDICATE THE SD IN THE RAG SPACE.
 IF SPACE IS CONSTRICTED, THE RAG MAY BE
 REQUIED TO BE MOVED, AS THE SD MUST BE
 OUTSIDE THE BEDRMS,BUT 3' FROM BATH DR.
 NFPA-72 11.8.3 2002
  
 5) NOTE: PLEASE SEE RISER IS MISSING THE
 SEC'S?
  
 6) NOTE: PLEASE SEE MISSING "EQUIPMENT
 GROUNDING CONDUCTOR" WHICH IS REQUIRED
 AFTER THE FIRST MEANS OF DISCONNECT.
 250.6,250.24B,250.110, SIZE PER 250.122
  
 7) NOTE: PLEASE SEE PANEL SHOWS WELL
 PUMP AS 2KW ON A 1-POLE 20A BRKR. PLEASE
 KNOW THE MAX VA PERMITTED ON THIS 20A
 CIRCUIT IS 1920VA.
 IS THIS NOT A 2-POLE 20A BRKR? PLEASE
 ADJUST.
 240.4,310.16,215.5 ETC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-05-01 Cont ID  
Sent By btrobaug Date 2006-05-01 Time 17:28 Rev Time 0.50
Received By btrobaug Date 2006-05-01 Time 17:13 Sent To M
Notes
2006-05-01 00:00:00 
  
 THE SERVICE MUST COMPLY WITH THE
 FOLLOWING:
  
 230.70(A)(1).
 (1) READILY ACCESSIBLE LOCATION. THE
 SERVICE DISCONNECTING MEANS SHALL BE
 INSTALLED AT A READILY ACCESSIBLE
 LOCATION EITHER OUTSIDE OF A BUILDING OR
 STRUCTURE OR INSIDE NEAREST THE POINT OF
 ENTRANCE OF THE SERVICE CONDUCTORS.
  
 THE NOTE ABOUT "RUNNING OVERHEAD IN
 TRUSSES" ON THE RISER DICTATES THAT A
 MAIN DISCONNECT BE LOCATED OUTSIDE,
 PREFERABLY BY THE METER. PLEASAE SHOW
 SAME ON RISER AND LOCATE THE MAIN ON THE
 PLAN.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2006-06-16 Cont ID  
Sent By ssherman Date 2006-06-16 Time 13:40 Rev Time 0.00
Received By ssherman Date 2006-06-16 Time 13:40 Sent To  
Notes
2006-06-16 00:00:00HISTORIC APPROVAL PER J PAPA

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-07-28 Cont ID  
Sent By adarroug Date 2008-07-28 Time 14:45 Rev Time 0.00
Received By adarroug Date 2008-07-28 Time 14:45 Sent To P
Notes
2008-07-28 14:45:40TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-05-19 Cont ID  
Sent By adarroug Date 2008-05-19 Time 12:01 Rev Time 0.00
Received By adarroug Date 2008-05-19 Time 12:01 Sent To P
Notes
2008-05-19 12:01:46TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-28 Cont ID  
Sent By adarroug Date 2007-08-28 Time 10:01 Rev Time 0.00
Received By adarroug Date 2007-08-28 Time 10:01 Sent To B
Notes
2007-08-28 10:01:59TO "LMARTINEZ" DESK/REV--(WAS SENT TO "LMARTINEZ" ON
 8/13/07 WITHOUT BEING LOGGED IN.)

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-20 Cont ID  
Sent By adarroug Date 2006-07-20 Time 13:35 Rev Time 0.00
Received By adarroug Date 2006-07-20 Time 13:35 Sent To E
Notes
2006-07-20 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-20 Cont ID  
Sent By adarroug Date 2006-06-20 Time 10:53 Rev Time 0.00
Received By adarroug Date 2006-06-20 Time 10:53 Sent To E
Notes
2006-06-20 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-27 Cont ID  
Sent By adarroug Date 2006-04-27 Time 09:17 Rev Time 0.00
Received By adarroug Date 2006-04-27 Time 09:17 Sent To E
Notes
2006-04-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-18 Cont ID  
Sent By alange Date 2006-05-18 Time 08:10 Rev Time 0.00
Received By alange Date 2006-04-19 Time 15:27 Sent To  
Notes
2006-04-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-05-03 Cont ID  
Sent By tgordon Date 2006-05-03 Time 14:46 Rev Time 0.45
Received By tgordon Date 2006-05-03 Time 14:46 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2008-07-29 Cont ID  
Sent By mperson Date 2008-07-29 Time 10:31 Rev Time 0.00
Received By mperson Date 2008-07-29 Time 10:31 Sent To PC
Notes
2008-07-29 10:35:09REVISION: "OK" AS BUILT SANITARY RISER DIAGRAM AND A
 LETTER FROM CONTRACTOR DECLARING THAT THE ORIGINAL
 ENGINEER OF RECORD IS NO LONGER LIVING IN THIS COUNTRY,
 THEREFORE A NEW ENGINEER HAS DRAWN THE REVISED SANITARY
 RISER.

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-06-24 Cont ID  
Sent By mperson Date 2008-06-24 Time 10:44 Rev Time 0.00
Received By mperson Date 2008-06-24 Time 10:44 Sent To PC
Notes
2008-06-24 11:16:18PLUMBING PLAN REVIEW:
 REVISION DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 1. ALL REVISIONS TO A SIGNED/SEALED SET OF PLANS SHALL
 BE SIGNED & SEALED BY THE ENGINEER OF RECORD. PER
 (W.P.B. AS AMENDED) SECTION 106.1.
 NOTE: THE ORIGINAL ENGINEER OF RECORD IS SENG-CHAI TAN
 PE LICENSE #46765, HOWEVER THE SUBMITTED PLUMBING
 REVISION IS SIGNED AND SEALED BY HENRY MELENDEZ, PE
 LICENSE #62946 WHO IS NOT THE ORIGINAL ENGINEER OF
 RECORD. PLEASE HAVE ORIGINAL ENGINEER OF RECORD SIGN,
 SEAL AND DATE REVISIONS.
  
 2. THE FOLLOWING ITEMS NEED TO BE CORRECTED ON THE
 SANITARY PLUMBING RISER REVISION:
  
 A} ISOMETRIC DOES NOT REFLECT THE FLOOR PLAN. THE
 LAVATORIES ARE BEING SHOWN AS BEING IN THE WALL NOT IN
 THE BATHROOMS AND WHAT KIND OF FITTING IS BEING USED IN
 THE SHOWER BATH FOR THE WATER CLOSET. AT A MINIMUM THE
 ISOMETRIC SHALL REFLECT THE FLOOR PLAN. PER FBC-
 PLUMBING SECTION 701.1 SCOPE.
  
 B} A 3 INCH CLEANOUT IS REQUIRED FOR THE WASHING
 MACHINE WASTE STACK AND SHALL BE LOCATED AT FOUR FEET
 ABOVE FINNISH FLOOR (4' A.F.F.). PER FBC- PLUMBING
 SECTION 708.3.4 AND 708.9 ACCESS.
  
 C} A TWO-WAY CLEANOUT IS REQUIRED AT THE JUCTION OF
 THE BUILDING DRAIN AND BUILDING SEWER. PER FBC-
 PLUMBING SECTION 708.3.5.
  
 D} THE 2 INCH VENT THRU THE ROOF ARE BEING INDICATED
 AS UTR, THEY SHOULD BE INDICATED AS VTR. PER FBC-
 PLUMBING SECTION 901.1 SCOPE.
  
 E} CLEARLY IDENTIFY WHAT KIND OF VENT IS BEING USED
 FOR THE KITCHEN SINK VENT. IS IT AN AIR ADMITTANCE
 VALVE (A.A.V.) OR IS IT A VENT THRU THE ROOF (VTR)? IT
 APPEARS THAT A 42" HIGH KNEE WALL IS AT THIS LOCATION
 AND AN A.A.V. SHOULD BE USED. PER FBC- PLUMBING SECTION
 901.1 SCOPE.
  
 F} CLEARLY IDENTIFY THE LAVATORY WASTE ARMS AS BEING
 1-1/2". PER FBC- PLUMBING SECTION 701.1 SCOPE.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 2 Status F Date 2008-06-03 Cont ID  
Sent By kstevens Date 2008-06-03 Time 09:52 Rev Time 0.00
Received By kstevens Date 2008-06-03 Time 09:52 Sent To  
Notes
2008-06-03 09:57:56REVISION DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 1. ALL REVISIONS TO A SIGNED/SEALED SET OF PLANS SHALL
 BE SIGNED & SEALED BY THE ENGINEER OF RECORD. SECTION
 106.106.1. SUBMIT A NEW SIGNED, SEALED, DATED ISOMETRIC
 RISER DIAGRAM THAT REFLECTS INSTALLATION.
  
 2. (INFORMATIONAL) ON THE REVISION SUBMITTAL FORM THE
 CONTRACTOR INDICATES THAT THEY ARE NOT SURE WHY THE
 INFORMATION WAS REQUESTED. WHEN THE INSTALLATION IS
 DIFFERENT FROM THE SIGNED/SEALED SET OF PLANS, THEN A
 REVISION IS REQUIRED FOR PUBLIC RECORD TO REFLECT
 CHANGES TO THE SAID PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING
 THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-05-05 Cont ID  
Sent By jleech Date 2006-05-05 Time 11:45 Rev Time 0.00
Received By jleech Date 2006-05-05 Time 11:45 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-04-26 Cont ID  
Sent By mmclean Date 2006-04-26 Time 13:19 Rev Time 0.00
Received By mmclean Date 2006-04-26 Time 13:19 Sent To I
Notes
***NONE***