Plan Review Details - Permit 05120621
Plan Review Stops For Permit 05120621
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-21 Cont ID  
Sent By amorse Date 2006-07-21 Time 13:37 Rev Time 0.00
Received By amorse Date 2006-07-21 Time 13:37 Sent To PC
Notes
2006-07-21 00:00:00 
  
  
 ***************REVISION****************
  
 MOVE POOL EQUIPMENT OK SENT TO PLUMBING
 AND ELECTICAL

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-02-08 Cont ID  
Sent By amorse Date 2006-02-08 Time 10:14 Rev Time 0.50
Received By amorse Date 2006-02-08 Time 10:14 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-07-21 Cont ID  
Sent By dpalmer Date 2006-07-21 Time 12:48 Rev Time 0.00
Received By dpalmer Date 2006-07-21 Time 12:48 Sent To B
Notes
2006-07-21 00:00:00*******UNSAT *********
  
 1) NOTE: PLEASE SEE REVSIONS CAME IN AS
 "MOVED LOCATION OF EQUIPMENT ONLY" , YET
 PLEASE SEE PLANS INDICATE ELECTRICAL
 CHANGES NOT ON ORIGIANL PLANS.
  
 ** PLEASE CLARIFY OF THIS IS INDEED A
 REVISION FOR OTHER ITEMS ALSO.
 IF SO, PLEASE SUBMIT LOD CALCULATIONS
 FROM EXISTING SERVICE, OCP FEEDING NEW
 PANEL AND SEE MISSING EQUIPMENT
 GROUNDING CONDUCTOR FROM EXISTING
 SERVICE TO NEW POOL PANEL.
 250.110,250.122,215.5,220.31
  
 ** PLEASE ALSO KNOW, ONLY NOTED TO
 CONTRACTOR TO VERIFY THE EXISTING
 OVERHEAD POWER LINES AS POOL IS SHOWN
 LESS THAN 1O FT FROM PROPERTY LINE.
 PLEASE
 SEE 680.8
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-01-23 Cont ID  
Sent By dpalmer Date 2006-01-23 Time 18:04 Rev Time 0.00
Received By dpalmer Date 2006-01-23 Time 18:04 Sent To  
Notes
2006-01-23 00:00:00SUBMITTIAL FROM 1/17/06 PLACED WITH
 PERMIT PACKAGE.
 2ND COPY OF SURVEY SUBMITTED, NEEDS A
 ZONING STAMP ON 2ND SET.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-12-28 Cont ID  
Sent By dpalmer Date 2005-12-28 Time 07:02 Rev Time 0.00
Received By dpalmer Date 2005-12-28 Time 07:02 Sent To P
Notes
2005-12-28 00:00:00REDLINED PLANS.
  
  
 ONLY ONE COPY OF PROPOSED SURVEY IN
 PACKAGE, TWO OTHERS IN PACKAGE, HOWEVER
 NEITHER SHOW POOL?
  
  
 PLANS REDLINED, MUST MAINTAIN ALL
 OVERHEAD CLEARENCES FROM POWER LINES,
 INCLUDING UTILITIES, 0-750 VOLTS ETC.
 THIS INCLUDES LINES IN EASEMENTS.
 680.8
 CONTRACTOR RESPONSIBLE TO MOVE POOL IF
 CLOSER THAN MIN.

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2006-07-20 Cont ID  
Sent By mperson Date 2006-07-20 Time 13:05 Rev Time 0.00
Received By mperson Date 2006-07-20 Time 13:05 Sent To E
Notes
2006-07-20 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2005-12-30 Cont ID  
Sent By mperson Date 2005-12-30 Time 10:53 Rev Time 0.00
Received By mperson Date 2005-12-30 Time 10:53 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-07-19 Cont ID  
Sent By adarroug Date 2006-07-19 Time 13:32 Rev Time 0.00
Received By adarroug Date 2006-07-19 Time 13:32 Sent To B
Notes
2006-07-19 00:00:00TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-15 Cont ID  
Sent By adarroug Date 2006-07-15 Time 10:18 Rev Time 0.00
Received By adarroug Date 2006-07-15 Time 10:18 Sent To Z
Notes
2006-07-15 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-01-19 Cont ID  
Sent By adarroug Date 2006-01-19 Time 09:40 Rev Time 0.00
Received By adarroug Date 2006-01-19 Time 09:40 Sent To E
Notes
2006-01-19 00:00:00TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-27 Cont ID  
Sent By adarroug Date 2005-12-27 Time 09:40 Rev Time 0.00
Received By adarroug Date 2005-12-27 Time 09:40 Sent To E
Notes
2005-12-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-02-08 Cont ID  
Sent By amorse Date 2006-02-08 Time 10:14 Rev Time 0.00
Received By amorse Date 2005-12-14 Time 09:11 Sent To  
Notes
2005-12-14 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-07-20 Cont ID  
Sent By mperson Date 2006-07-20 Time 11:52 Rev Time 0.00
Received By mperson Date 2006-07-20 Time 13:05 Sent To G
Notes
2006-07-20 00:00:00REVISION: CHANGED LOCATION OF THE POOL
 EQUIPMENT PAD.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-12-30 Cont ID  
Sent By mperson Date 2005-12-30 Time 10:54 Rev Time 1.25
Received By mperson Date 2005-12-30 Time 10:53 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2006-07-18 Cont ID  
Sent By mmclean Date 2006-07-18 Time 18:00 Rev Time 0.00
Received By mmclean Date 2006-07-18 Time 18:00 Sent To I
Notes
2006-07-18 00:00:00THE PROPOSED POOL EQUIPMENT SHALL NOT BE
 CLOSER THAN 1FT FROMSIDE PROPERTY
 LINE.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-02-06 Cont ID  
Sent By mmclean Date 2006-02-06 Time 13:24 Rev Time 0.00
Received By mmclean Date 2006-02-06 Time 13:25 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-12-23 Cont ID  
Sent By mmclean Date 2005-12-23 Time 17:08 Rev Time 0.00
Received By mmclean Date 2005-12-23 Time 17:08 Sent To I
Notes
***NONE***