Plan Review Details - Permit 05120547
Plan Review Stops For Permit 05120547
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-01-03 Cont ID  
Sent By rmcdouga Date 2006-01-03 Time 11:01 Rev Time 0.00
Received By rmcdouga Date 2006-01-03 Time 11:01 Sent To  
Notes
2006-01-03 00:00:00DENIED
  
 1) CONSTRUCTION DOCUMENTS ARE REQUIRED
 TO BE PREPARED BY A DESIGN PROFESSIONAL
 PER FLORIDA STATUTES 481.229 AND
 471.003.
  
 2) CITY AMENDMENTS TO FBC 106.1.1
 REQUIRES PLANS TO BE DIMENSIONED AND OF
 SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED. THE PLANS THAT WERE SUBMITTED
 DO NOT REFLECT THE DESCRIPTION OF WORK
 ON THE PERMIT APPLICATION.
  
 3) FBC 106.1.3 REQUIRES PLANS TO BE A
 MINIMUM 1/8" SCALE.
  
 4) TWO COMPLETE SETS OF PLANS ARE
 REQUIRED PER FBC 106.1.
  
 5) SPECIFY THE CONSTRUCTION TYPE FOR THE
 BUILDING PER 2004 FBC SECTION 602. NOTE:
 WOOD FRAMING IS NOT ALLOWED IN TYPE I OR
 TYPE II CONSTRUCTION.
  
 6) SPECIFY THE FIRE RATED ASSEMBLY THAT
 WILL BE INSTALLED AT THE TENANT
 SEPARATION WALLS. PROVIDE A WALL
 SECTION. SPECIFY THE LISTING NUMBER AND
 AGENCY FOR THE FIRE RATED ASSEMBLY.
  
 7) FBC 1210.3 REQUIRES SHOWER
 COMPARTMENTS AND WALLS ABOVE BATHTUBS
 WITH INSTALLED SHOWER HEADS TO BE
 FINISHED WITH NONABSORBENT SURFACES.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-12-16 Cont ID  
Sent By jleahy Date 2005-12-16 Time 18:58 Rev Time 0.45
Received By jleahy Date 2005-12-16 Time 18:58 Sent To  
Notes
2005-12-16 00:00:00ONLY HAVE ONE SET OF PLANS
  
 NEED LOAD CALCULATION
  
 NEED PANEL SCHEDULE
  
 KITCHEN COUNTER DOES NOT APPEAR TO MEET
 OUTLET SPACING PER CODE.
  
 BATHROOM DOES NOT SHOW AND OUTLET, IT
 HAS TO HAVE ONE AND IT SHALL BE GFCI.
  
  
 JAKE LEAHY644-7291

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-12-21 Cont ID  
Sent By mcarsill Date 2005-12-21 Time 12:57 Rev Time 0.00
Received By mcarsill Date 2005-12-21 Time 12:48 Sent To  
Notes
2005-12-21 00:00:001. SMOKE DETECTORS SHALL BE LOCATED AT
 LEAST THREE FEET FROM AIR CONDITIONING
 DIFFUSERS.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
 804-4709

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-12-20 Cont ID  
Sent By mwennerg Date 2005-12-20 Time 14:40 Rev Time 0.00
Received By mwennerg Date 2005-12-20 Time 14:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-20 Cont ID  
Sent By adarroug Date 2005-12-20 Time 11:37 Rev Time 0.00
Received By adarroug Date 2005-12-20 Time 11:37 Sent To  
Notes
2005-12-20 00:00:00TO "BOB"#13

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-01-03 Cont ID  
Sent By rmcdouga Date 2006-01-03 Time 11:33 Rev Time 0.00
Received By rmcdouga Date 2005-12-13 Time 13:26 Sent To  
Notes
2005-12-13 00:00:00TO "BOB"#10

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-12-20 Cont ID  
Sent By tgordon Date 2005-12-20 Time 14:21 Rev Time 0.15
Received By tgordon Date 2005-12-20 Time 14:21 Sent To  
Notes
2005-12-20 00:00:00NO MACH. PLANS OR MECH. CONTRACTOR
 SUBMITTED AT THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-12-15 Cont ID  
Sent By jleech Date 2005-12-15 Time 13:32 Rev Time 0.33
Received By jleech Date 2005-12-15 Time 13:32 Sent To  
Notes
2005-12-15 00:00:00FIXTURE CHANGE OUT ONLY