| Plan Review Stops For Permit 05120487 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-11-13 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-13 |
Time |
13:50 |
Sent To |
|
|
| Notes |
| 2006-11-13 13:54:00 | REVISION DATED 10/30, REPAIR DETAIL WALLS @ MECHANICAL | | | SHAFTS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-11-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-11-05 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-11-05 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2006-11-05 15:59:47 | REVISION A8 DATED 10-20-06 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-09-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-09-01 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-09-01 |
Time |
13:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-07-18 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-07-18 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | ***CORRECTIONS*** | | | ***MAJOR WORKING DRAWING REVIEW*** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | NOTE - NO PLANS SUBMITTED ON FIRST | | | REVIEW, REPORT ONLY. | | | | | | 1.)THE PRODUCT APPROVAL SUBMITTED | | | FL6872 IS PENDING.CURRENT PRODUCT | | | APPROVAL REQUIRED, FAC9B72.IF THE | | | PRODUCT APPROVAL IS STILL PENDING AT THE | | | TIME OF RESUBMITTAL, PLEASE ADVISE AND A | | | LOCAL PRODUCT APPROVAL WILL BE ISSUED | | | USING THE NOA. | | | | | | 2.)PROVIDE INFORMATION IN REGARDS TO | | | THE EXISTING BUILDING - MINIMUM BUILDING | | | TYPE FBC6 (INCLUDE A OR B), AREA, | | | OCCUPANCY FBC3. | | | | | | 3.)RELATED TO COMMENT #2 ABOVE, | | | SEVERAL DETAILS A7 SHOW COMBUSTIBLE | | | FRAMING.IS THIS ALLOWED? | | | | | | 4.)DECLARE GOVERNING CODE, INCLUDING | | | FBC 2004 EXISTING BUILDING CODE. | | | | | | 5.)DECLARE LEVEL OF ALTERATION, FBC EB | | | 3. | | | | | | 6.)FS SHEETS ARE NOT SIGNED, SEALED | | | AND DATED FAC61G15-23.002.THE | | | INFORMATION REQUIRED TO BE ON THE TITLE | | | BLOCK IS ILLEGIBLE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-27 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-27 |
Time |
13:12 |
Sent To |
|
|
| Notes |
| 2006-03-27 00:00:00 | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | | | | | | | 1.)NO BUILDING PLANS SUBMITTED. | | | | | | 2.)FOR PERMITTING PURPOSES, SUBMIT A | | | DETAIL OF THE 1 HOUR INFILL IN THE | | | CORRIDOR.PROVIDE A UL ASSEMBLY OR | | | CALCULATED FIRE RESISTANCE FBC7. | | | | | | 3.)THE ENGINEER'S REPORT IS TO COMPLY | | | WITH FAC61G15-23.002.THE COFA NUMBER, | | | PRINTED LICENSE NUMBER OF THE PERSON | | | SEALING THE DOCUMENT ARE TO BE ON THE | | | PLAN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-31 |
Time |
08:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-30 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
| 2006-12-31 08:22:19 | REV FOR ADDING ONE HOUSE PANEL AND HALLWAY PHOTOMETRICS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-12-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-20 |
Time |
19:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-20 |
Time |
19:10 |
Sent To |
PC |
|
| Notes |
| 2006-12-20 19:39:07 | ** UNSAT ** | | | | | | 1) NOTE:NOTE OK, AS THE ELECTRICAL PERMIT WAS NOT | | | AATCHED IN COMPUTER SYSTEM, PREVIOUS NOTE FOR 4X FEE | | | AND HOLD REMOVED. | | | | | | | | | 2) NOTE: PLEASE COMPLETE PHOTO-METRICS AS PARTIALLY | | | SHOWN FOR HALLWAYS/EGRESS PATHS. | | | PLEASE SEE MINIMUM LIGHTING LEVELS UNDER NORMAL AND | | | EMERGENCY ARE REQUIRED. | | | PLEASE SEE NFPA-101 2003 7.8, 7.9 | | | PLEASE SEE ONLY A PARTIAL HALLWAY IS SHOWN FOR LIGHTING | | | LEVELS WHICH ARE ONLY JUST OVER MINIMUM AND OTHER AREAS | | | OF HALLWAYS NOT SHOWN CONTAIN LESS LIGHTING FIXTURES IS | | | OF CONCERN TO THIS OFFICE. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-25 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-25 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-30 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-30 |
Time |
18:02 |
Sent To |
|
|
| Notes |
| 2006-06-30 00:00:00 | *****UNSAT ***** | | | 1ST REVIEW, ELECTRICAL PLANS NOW | | | SUBMITTED. | | | | | | | | | ** PLEASE KNOW, PLANS ARE STILL ONLY | | | BEING SUBMITTED FOR "PLAN REVIEW" AND | | | HAVE NOT SUBMITTED FOR PERMIT. | | | | | | | | | 1) NOTE: PLEASE SEE MISSING REQUIRED | | | INFORMATION ON TITLE BLOCK FOR THE | | | ARCHITECTURAL FIRM. FAC 61G1-16.004. | | | PLEASE SEE MISSING THE PRINTED NAME AND | | | LICENSE NUMBER OF ARCHITECT, AND MISSING | | | THE CERTIFICATE OF AUTHORIZATION NUMBER | | | FOR ARCHITECTURAL FIRM. | | | THIS IS REQUIRED ON ALL SHEETS | | | CONTAINING A TITLE BLOCK FOR SADI FIRM. | | | ** THIS IS REQUIRED FOR ALL TRADES AND | | | FOR REVIEW WHETHER OR NOT COMMENT IS | | | MADE BY OTHER TRADES. | | | | | | 2) NOTE: PLEASE SEE FS SHEETS SUBMITTED | | | ARE NOT SIGNED,DATED, OR SEALED?? | | | PLEASE KNOW, IF THESE ARE SUBMITTED AS | | | PART OF THIS SETS FOR RECORD, EVEN IF | | | THE FS ARE UNDER SEPARATE PERMIT, THE | | | SHEETS SHALL BE SIGNED, DATED, AND | | | SEALED. | | | FS 471.025, FAC 61G15-23.002 | | | | | | 3) NOTE: PLEASE KNOW, WHEN THIS IS BEING | | | SUBMITTED FOR PERMIT, THE COMPLETE VALUE | | | FOR SCOPE OF WORK SHALL INCLUDE ALL | | | LABOUR AND MATERIALS, WHETHER OR NOT ANY | | | MATERIALS ARE OWNER SUPPLIED. | | | FBC 108.3 ADMIN SECT. | | | | | | 4) NOTE: PLEASE SEE THAT CONDUCTOR TYPE | | | SHALL BE INDICATED. | | | 215.5, | | | 106.1.2 FBC ADMIN SECT. | | | | | | 5) NOTE: PLEASE PROVIDE PHOTO-METRICS | | | FOR HALL WAYS. THIS CAN BE A TYPICAL | | | DETAIL AND SECTION AS EACH FLR SEEMS | | | TYPICAL. | | | NFPA-101 7.8, 7.9 PLEASE SEE A MIN OF | | | 1FT CANDLE SHALL BE PROVIDED UNDER | | | NORMAL AND EMCONDITIONS. | | | | | | 6) NOTE: PLEASE SEE THAT NOW, EACH OF | | | THESE UNITS HAVE BECOME "CONDOS", THE | | | WASHER AND DRYER RECEPT CIRCUIT WIRING | | | SHALL NOT BE INCLUDE ON THESE PLANS FOR | | | SCOPE OF WORK. | | | THE CALCULATIONS FOR THE ADDED LOAD TO | | | EACH METER BACNK AND MAIN SERVICE SHOUDL | | | REMAIN IN SETS. | | | 215.5 | | | | | | 7) NOTE: PLEASE SEE PANEL LOCATIONS. | | | UNABLE TO VERIFY WHICH SIDE OF THE | | | PANELS SHOWN ARE THE ACCESSIBLE/OPENING | | | SIDE. THE OPEING SIDE SHOULD ALL MEET | | | 110.26 AND CORRELATE. | | | 215.5 | | | | | | 8) NOTE: PLEASE SEE THAT THE ADDRESS FOR | | | PROJECT SHALL BE INDICATED ON ALL | | | SHEETS. | | | FAC 61G1-16.004, FAC 61G15-23.002 | | | PLEASE SEE ONLY THE "A" SHEETS CONTAINS | | | AN ADDRESS OF 1830 EMBASSY DR. | | | | | | 9) NOTE: PLEASE SEE LOAD CALCULATIONS | | | WHICH REFLECT NEC 220.84?? | | | UNABLE TO LOCATED THIS REFERENCE IN THE | | | CURRENT WE ARE UNDER IN THE STATE OF | | | FLORIDA. | | | NEC 2002 | | | | | | 10) NOTE: PLEASE SEE THAT PLANS REFLECT | | | THE FOLLOWING CODES. | | | 2004 FBC, 2002 NFPA-70(NEC), 2002 | | | NFPA-72, 2003 NFPA-101 | | | | | | 11) NOTE: PLEASE CLARIFY WHERE MAIN 1OF6 | | | IS?? RISER SHOWS 2OF6, THRU 6OF6. | | | 215.5 | | | | | | 12) NOTE: PLEASE SEE WHEN RESUBMITTING | | | PLANS TO BE SURE AN MAKE TWO COMPLETE | | | SETS FOR REVIEW AND STAMPING. PLEASE SEE | | | SOME ELECTRICAL SHEETS WERE IN SEPARATE | | | SETS. | | | 106.1.3 | | | | | | 13) NOTE: PLEASE BE SURE TO ADJUST SCOPE | | | OF WORK ON APPLICATION AS THIS DOES NOT | | | INCLUDE ALL THE REFEEDS TO HOUSE PANELS, | | | "CONDO"PANELS AND METER BANKS. | | | PLEASE SEE APPL MENTIONS INSTALLATION OF | | | GFI RECEPTS, YET THESE COULD NOT BE | | | LOCATED. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2006-08-01 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2006-07-26 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | PROVISO: | | | | | | THE PREVIOUS COMMENTS FROM THE FIRST | | | REVIEW BY FIRE MARSHAL MIKE CARSILLO | | | STILL REQUIRED. | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2006-01-23 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2006-01-23 |
Time |
13:36 |
Sent To |
|
|
| Notes |
| 2006-01-23 00:00:00 | THIS OFFICE HAS REVIEWED THE SCHIRMER | | | ENGINEERING REPORT, FIRE SAFETY | | | EVALUATION REPORT PREPARED FOR BH | | | CONDOMINIUM SERVICES, LLC. THE FOLLOWING | | | COMMENTS ARE PROVIDED. | | | | | | 1. PLANS AND PERMITS REQUIRED FOR THE | | | REMOVAL OF THE EXISTING TRANSFER GRILLS | | | AND TO REPAIR THESE LOCATIONS TO THE ONE | | | HOUR FIRE RATING. (CORRIDORS) | | | | | | 2. THE REPLACEMENT OF DOORS AND EXIT | | | HARDWARE IN THE STAIRWELLS SHOULD ALSO | | | BE INCLUDED ON PLANS WITH AN APPROVED | | | DOOR SCHEDULE ILLUSTRATING THE NEW 1 1/2 | | | HOUR RATED DOORS. | | | | | | 3. STAIR IDENTIFICATION SIGNS WILL | | | CERTAINLY HELP TO IMPROVE THE OVERALL | | | FIRE AND LIFE SAFETY CONDITIONS AT THE | | | BUILDING. | | | | | | 4. THE PROPOSED NEW FIRE ALARM SYSTEM | | | SHALL MEET ALL OF THE REQUIREMENTS OF | | | NFPA 72, 2002 EDITION. PLANS AND PERMITS | | | WILL BE REQUIRED PRIOR TO INSTALLATION. | | | SINCE A NEW SYSTEM IS EXPECTED, THE | | | SYSTEM SHALL BE MONITORED BY A LICENSED | | | UL LISTED CENTRAL STATION APPROVED FOR | | | CENTRAL STATION SERVICE. | | | | | | | | | 5. THIS OFFICE HAS REVIEWED THE | | | INFORMATION REGARDING THE PARTIAL FIRE | | | SPRINKLER PROTECTION.THIS OFFICE WOULD | | | RECOMMEND THAT THE ENTIRE BUILDING BE | | | FIRE SPRINKLER PROTECTED.AS YOU ARE | | | AWARE, THE MOST SEVERE RISK OF FIRE IS | | | LOCATED WITHIN THE RESIDENTIAL UNITS OF | | | THE BUILDING. SINCE THE PLAN IS TO | | | SPRINKLER ONLY THE CORRIDORS AND THE | | | STAIRS, THE REQUIRED INFRASTRUCTURE WILL | | | HAVE TO BE INSTALLED.WITH THE ADDITION | | | OF FIRE SPRINKLER PIPING AND SPRINKLER | | | HEADS THE ENTIRE BUILDING COULD BE | | | PROTECTED WITH SPRINKLERS. FIRE | | | SPRINKLER HEADS SELECTED SHOULD BE QUICK | | | RESPONSE OR LISTED RESIDENTIAL TYPE. | | | SEPERATE PLANS AND PERMITS REQUIRED FOR | | | THE INSTALLATION OF ANY FIRE SPRINKLER | | | SYSTEM. | | | | | | 6. THE REPORT INDICATES THAT A NEW FIRE | | | PUMP AND JOCKEY PUMP IS PLANNED. THIS | | | OFFICE SUPPORTS THE INSTALLATION OF A | | | NEW FIRE PUMP AND JOCKEY PUMP AS THE | | | EXISTING FIRE PUMP HAS BEEN UTILIZED FOR | | | MANY YEARS AND HAS OUTLIVED ITS | | | USEFULNESS. THE NEW FIRE PUMP SHOULD BE | | | AS LEAST A 750 GPM FIRE PUMP SINCE THERE | | | ARE TWO REQUIRED STAIRWELLS FOR THE | | | BUILDING. AGAIN, PLANS AND PERMITS ARE | | | REQUIRED PRIOR TO INSTALLATION. ALSO | | | PRIMARY AND EMERGENCY POWER SUPPLIES ARE | | | TO BE DETERMINED FOR ADEQUACY. | | | | | | 7. ALTHOUGH NOT NOTED IN THE REPORT, ANY | | | MULTI-LEVEL APARTMENTS SHALL HAVE | | | ELECTRIC POWERED SMOKE DETECTORS PRESENT | | | ON EVERY LEVEL. | | | | | | 8. ANY OTHER FIRE AND LIFE SAFETY | | | SYSTEMS OR DEVICES THAT NEED TO BE | | | REPAIRED SHOULD BE CORRECTED AT THIS | | | TIME. | | | | | | IF YOU SHOULD HAVE ANY QUESTIONS, PLEASE | | | FEEL FREE TO CONTACT THIS OFFICE AT | | | 804-4709. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-27 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-27 |
Time |
15:47 |
Sent To |
E |
|
| Notes |
| 2006-12-27 15:48:34 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-17 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-17 |
Time |
13:05 |
Sent To |
E |
|
| Notes |
| 2006-12-17 13:05:46 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-13 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-13 |
Time |
11:22 |
Sent To |
B |
|
| Notes |
| 2006-11-13 11:24:00 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-27 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-27 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
| 2006-10-27 15:52:18 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-16 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-16 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2006-08-23 00:00:00 | TO "COMM" BD#33 | | 2006-08-16 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-21 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-21 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2006-06-29 00:00:00 | TO "COMM" BD#57 | | 2006-06-21 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-07 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2005-12-13 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2006-01-13 00:00:00 | TO "COMM" BD#42 | | 2005-12-13 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-08-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-24 |
Time |
13:36 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-08-24 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-18 |
Time |
15:32 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-07-18 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | *** DENIED *** | | | 1) BATHROOM EXHAUST FANS MAY NOT | | | DISCHARGE INTO AN INCLOSED HALLWAY, OR | | | ON TO A WALKWAY, AND MUST DISCHARGE TO | | | THE OUTDOORS ,PER 2004 FBC/M 501.2, AND | | | 401.5.2 . | | | | | | 2) PLEASE PROVIDE INFORMATION AND | | | INSTALLATION DETAILS ON THE FIRE DAMPERS | | | FOR THE BATHROOM EXHAUST FANS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-07-20 |
Time |
20:05 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-07-20 |
Time |
20:05 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-07 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-04-07 |
Time |
20:07 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-04-07 |
Time |
20:07 |
Sent To |
I |
|
| Notes |
| 2006-04-07 00:00:00 | PLANNING AND ZONING:FAILED | | | | | | 1.PROVIDE A COPY OF THE ZONING | | | CONFIRMATION LETTER FROM THE CITY | | | VERYING THE INTENT TO CONVERT THESE | | | APARTMENTS TO CONDOS. IF SUCH LETTER WAS | | | NOT PREVIOUSLY ASKED FOR, YOU WILL NEED | | | TO CONTACT THE PLANNING DEPARTMENT OR GO | | | TO OUR WEBSITE: WWW.CITYOFWPB.ORG | | | UNDER ZONING REQUESTS TO DOWNLOAD A | | | ZONING CONFIRMATION LETTER REQUEST AND | | | INSTRUCTIONS. | | | | | | 2.THE PACKET SUBMITTED IS NOT SUFFICIENT | | | TO PROVIDE INFORMATION SUCH AS, WHAT | | | TYPE OF IMPROVEMENTS ARE BEING PROPOSED. | | | PROVIDE AN EXISTING SURVEY OF THE SITE | | | AND A WRITTEN EXPLANATION OF THE EXTENT | | | OF THE WORK TO BE PERFORMED. | | | | | | 3. DO YOU HAVE A COPY OF THE | | | DOCUMENTATION TO MEET THECONDO | | | CONVERTION REQUIREMENTS FROM THE STATE | | | OF FLORIDA? IF SO, PLEASE PROVIDE A COPY | | | IN THE RE-SUBMITTAL PACKET. | | | | | | | | | IF YOU HAVE ANY QUESTIONS IN REGARDS TO | | | THESE COMMENTS, PLEASE CONTACT LINDA MIA | | | FRANCO, SENIOR PLANNER AT (561)822-1435. | | | | | | | | | |
|
|