Plan Review Details - Permit 05120321
| Plan Review Stops For Permit 05120321 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-01-13 |
Time |
12:12 |
Rev Time |
1.00 |
| Received By |
mjacobs |
Date |
2006-01-13 |
Time |
11:29 |
Sent To |
PC |
|
| Notes |
| 2006-01-13 00:00:00 | 1) CONSTRUCTION DOCUMENTS, SPECIAL | | | INSPECTION AND STRUCTURAL OBSERVATION | | | PROGRAMS, AND OTHER DATA SHALL BE | | | SUBMITTED IN TWO OR MORE SETS WITH EACH | | | APPLICATION FOR A PERMIT.FBC.106.1 | | | | | | 2)IF THE DESIGN PROFESSIONAL IS AN | | | ARCHITECT OR ENGINEER LEGALLY REGISTERED | | | UNDER THE LAWS OF THIS STATE REGULATING | | | THE PRACTICE OF ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, | | | PART I, OR ENGINEERING AS PROVIDED FOR | | | IN CHAPTER 471, FLORIDA STATUTES, THEN | | | HE OR SHE SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL TO SAID DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA, AS | | | REQUIRED BY FLORIDA STATUTE. | | | | | | 3) SHOW ON EACH TABLE OF THE DRAWINGS | | | WHICH COLUM OR ROW WILL BE USE FOR THE | | | CONSTRUCTION OF THE SHED. | | | | | | 4)ALL PLANS SUBMITTED AFTER OCTOBER, 1, | | | 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-27 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-27 |
Time |
10:01 |
Sent To |
B |
|
| Notes |
| 2005-12-27 00:00:00 | TO "MISC" BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-01-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2005-12-12 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-22 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-22 |
Time |
18:23 |
Sent To |
I |
|
| Notes |
| 2005-12-22 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO CURRENT COPY OF | | | SURVEY SHOWING THE LOCATION OF PROPOSED | | | SHED WITH SETBACKS FROM PROPERTY LINE | | | (SIDE/REAR) | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
|
Account Summary | Usage Policy | Privacy Policy