| Plan Review Stops For Permit 05120306 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-02-06 |
Time |
15:38 |
Rev Time |
1.00 |
| Received By |
mjacobs |
Date |
2006-02-06 |
Time |
14:29 |
Sent To |
PC |
|
| Notes |
| 2006-02-06 00:00:00 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST | | | STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-01-17 |
Time |
14:06 |
Rev Time |
1.25 |
| Received By |
mjacobs |
Date |
2006-01-17 |
Time |
09:10 |
Sent To |
PC |
|
| Notes |
| 2006-01-17 00:00:00 | 1)THE VALUE OF THE POOL WITH DECK IS TOO | | | LOW ACCORDING TO "MARSHALL-SWIFT" | | | PLEASE ADJUST THE VALUE TO FAIR MARKET | | | VALUE OR WE WILL ADJUST THE VALUE | | | ACCORDINGLY. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-03 |
Time |
18:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-03 |
Time |
17:49 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-28 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-28 |
Time |
12:11 |
Sent To |
P |
|
| Notes |
| 2005-12-28 00:00:00 | ****** UNSAT ******** | | | | | | | | | 1)NOTE: PLEASE SEE NO ELECTRICAL PLANS/ | | | DETAILS WERE SUBMITTED FOR NEW POOL | | | ELECTRICAL WIRING. | | | PLEASE SUBMIT TO CONFORM TO NEC 2002. | | | | | | 2)NOTE: PLEASE SEE BLDG REVIEW FOR | | | VALUATION OF PERMIT APPLICATION WHICH IS | | | STATED WAY TOO LOW FOR A POOL THIS SIZE. | | | PLEASE ADJUST VALUE TO AN APPROPRIATE | | | VALUE, OR ONE MAY BE ACCESSED FROM THE | | | CURRENT MARSHALL'S/ SWIFT GUIDE AS | | | ADOPTED BY SBCCI, FBC. | | | 108.3 | | | | | | PLEASE SUBMIT THE ABOVE INFOMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2005-12-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2005-12-30 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2005-12-30 |
Time |
08:05 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-02 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-02 |
Time |
16:03 |
Sent To |
E |
|
| Notes |
| 2006-02-02 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-24 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-24 |
Time |
10:58 |
Sent To |
Z |
|
| Notes |
| 2006-01-24 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-27 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-27 |
Time |
10:49 |
Sent To |
E |
|
| Notes |
| 2005-12-27 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-01-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-12 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2005-12-12 00:00:00 | TO 'Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-02-06 |
Time |
11:40 |
Rev Time |
1.00 |
| Received By |
mperson |
Date |
2006-02-06 |
Time |
11:40 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2005-12-30 |
Time |
08:07 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2005-12-30 |
Time |
08:06 |
Sent To |
B |
|
| Notes |
| 2005-12-30 00:00:00 | DENIED | | | | | | REFERENCE: FBC-2004 424.2 SWIMING POOLS | | | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | | FORMATION REQUIRED FOR PLAN REVIEW. | | | 1) FBC-2004 SEC 424.2.6.6 ENTRAPMENT | | | PROTECTION FOR SUCTION INLETS. (DETAIL) | | | 2) FBC-2004424.2.6.6.2 SHOW COMPLIANCE | | | WITH ANSI/ASME A112.19.8M. PROVIDE MODEL | | | NUMBER AND MANUF INFO FOR VAC LOCK. | | | (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES) | | | 3) FBC-2004424.2.6.6.3 (1,2,3) ENTRAP- | | | MENT AVOIDANCE. (DETAIL) | | | 4) FBC-2004424.2.6.6.4 MINIMUM OF TWO | | | SUCTION INLETS SHALL BE PROVIDED FOR EA | | | PUMP. SEPARATED BY A MINIMUM OF 3 FEET | | | OR LOCATED ON TWO DIFFERENT PLANES. | | | (DETAIL) | | | 5) FBC-2004424.2.6.6.5 WHERE PROVIDED, | | | THE VACUUM OR PRESSURE CLEANER FITTING | | | SHALL BE LOCATED AT LEAST 6" AND NOT | | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | | THE SKIMMER.(DETAIL) | | | 6) FBC-2004 424.2.7.2 PUMPS AND | | | EQUIPMENT SHALL BE MOUNTED ON A | | | SUBSTANTIAL BASE IN A MANNER THAT WILL | | | ELIMINATE STRAIN ON PIPING.SLAB SHALL | | | BE A NOMINAL 4" THICK. (DETAIL) | | | 7) FBC-2004 424.2.9 WATER SUPPLY, LOCAL | | | ORD.#2853-95, BACKFLOW REQUIRED ON WATER | | | SERVICE.(ADD TO NOTES) | | | 8) FBC-2004 BLDG. 13-612.1.ABC.2.3.3 | | | TIME CLOCKS SHALL BE INSTALLED ON | | | PRIVATE POOLS. | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-31 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-31 |
Time |
17:28 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-22 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-22 |
Time |
17:39 |
Sent To |
I |
|
| Notes |
| 2005-12-22 00:00:00 | DENIED, | | | 1. MUST PROVIDE TWO COPY OF CURRENT | | | SURVEY SHOWING THE PROPOSED WORK WITH | | | SETBACKS. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|