Plan Review Details - Permit 05120306
Plan Review Stops For Permit 05120306
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-02-06 Cont ID  
Sent By mjacobs Date 2006-02-06 Time 15:38 Rev Time 1.00
Received By mjacobs Date 2006-02-06 Time 14:29 Sent To PC
Notes
2006-02-06 00:00:00BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-01-17 Cont ID  
Sent By mjacobs Date 2006-01-17 Time 14:06 Rev Time 1.25
Received By mjacobs Date 2006-01-17 Time 09:10 Sent To PC
Notes
2006-01-17 00:00:001)THE VALUE OF THE POOL WITH DECK IS TOO
 LOW ACCORDING TO "MARSHALL-SWIFT"
 PLEASE ADJUST THE VALUE TO FAIR MARKET
 VALUE OR WE WILL ADJUST THE VALUE
 ACCORDINGLY.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-03 Cont ID  
Sent By dpalmer Date 2006-02-03 Time 18:13 Rev Time 0.00
Received By dpalmer Date 2006-02-03 Time 17:49 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-12-28 Cont ID  
Sent By dpalmer Date 2005-12-28 Time 12:12 Rev Time 0.00
Received By dpalmer Date 2005-12-28 Time 12:11 Sent To P
Notes
2005-12-28 00:00:00****** UNSAT ********
  
  
 1)NOTE: PLEASE SEE NO ELECTRICAL PLANS/
 DETAILS WERE SUBMITTED FOR NEW POOL
 ELECTRICAL WIRING.
 PLEASE SUBMIT TO CONFORM TO NEC 2002.
  
 2)NOTE: PLEASE SEE BLDG REVIEW FOR
 VALUATION OF PERMIT APPLICATION WHICH IS
 STATED WAY TOO LOW FOR A POOL THIS SIZE.
 PLEASE ADJUST VALUE TO AN APPROPRIATE
 VALUE, OR ONE MAY BE ACCESSED FROM THE
 CURRENT MARSHALL'S/ SWIFT GUIDE AS
 ADOPTED BY SBCCI, FBC.
 108.3
  
 PLEASE SUBMIT THE ABOVE INFOMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2005-12-30 Cont ID  
Sent By mperson Date 2005-12-30 Time 08:05 Rev Time 0.00
Received By mperson Date 2005-12-30 Time 08:05 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-02-02 Cont ID  
Sent By adarroug Date 2006-02-02 Time 16:03 Rev Time 0.00
Received By adarroug Date 2006-02-02 Time 16:03 Sent To E
Notes
2006-02-02 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-01-24 Cont ID  
Sent By adarroug Date 2006-01-24 Time 10:58 Rev Time 0.00
Received By adarroug Date 2006-01-24 Time 10:58 Sent To Z
Notes
2006-01-24 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-27 Cont ID  
Sent By adarroug Date 2005-12-27 Time 10:49 Rev Time 0.00
Received By adarroug Date 2005-12-27 Time 10:49 Sent To E
Notes
2005-12-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-01-17 Time   Rev Time 0.00
Received By adarroug Date 2005-12-12 Time 14:49 Sent To  
Notes
2005-12-12 00:00:00TO 'Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-02-06 Cont ID  
Sent By mperson Date 2006-02-06 Time 11:40 Rev Time 1.00
Received By mperson Date 2006-02-06 Time 11:40 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-30 Cont ID  
Sent By mperson Date 2005-12-30 Time 08:07 Rev Time 1.25
Received By mperson Date 2005-12-30 Time 08:06 Sent To B
Notes
2005-12-30 00:00:00DENIED
  
 REFERENCE: FBC-2004 424.2 SWIMING POOLS
  
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW.
 1) FBC-2004 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 2) FBC-2004424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 3) FBC-2004424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)
 4) FBC-2004424.2.6.6.4 MINIMUM OF TWO
 SUCTION INLETS SHALL BE PROVIDED FOR EA
 PUMP. SEPARATED BY A MINIMUM OF 3 FEET
 OR LOCATED ON TWO DIFFERENT PLANES.
 (DETAIL)
 5) FBC-2004424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.(DETAIL)
 6) FBC-2004 424.2.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL)
 7) FBC-2004 424.2.9 WATER SUPPLY, LOCAL
 ORD.#2853-95, BACKFLOW REQUIRED ON WATER
 SERVICE.(ADD TO NOTES)
 8) FBC-2004 BLDG. 13-612.1.ABC.2.3.3
 TIME CLOCKS SHALL BE INSTALLED ON
 PRIVATE POOLS.
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
  
  
  
  

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-31 Cont ID  
Sent By mmclean Date 2006-01-31 Time 17:28 Rev Time 0.00
Received By mmclean Date 2006-01-31 Time 17:28 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-22 Cont ID  
Sent By mmclean Date 2005-12-22 Time 17:39 Rev Time 0.00
Received By mmclean Date 2005-12-22 Time 17:39 Sent To I
Notes
2005-12-22 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF CURRENT
 SURVEY SHOWING THE PROPOSED WORK WITH
 SETBACKS.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720