| Plan Review Stops For Permit 05120225 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-03-02 |
Time |
09:13 |
Rev Time |
0.75 |
| Received By |
mjacobs |
Date |
2006-03-02 |
Time |
08:43 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-01-26 |
Time |
10:51 |
Rev Time |
2.00 |
| Received By |
mjacobs |
Date |
2006-01-26 |
Time |
06:55 |
Sent To |
PC |
|
| Notes |
| 2006-01-26 00:00:00 | 1) TWO COPIES OF EACH DRAWINGS IS | | | REQUIRED FOR PLAN REVIEW. ONLY ONE SET | | | OF EACH IS IN THE PACKAGE. | | | | | | 2) THE ANCHORING PLAN NEEDS ORIGINAL | | | SEAL AND SIGNATURE BY THE ARCHITECT OR | | | ENGINEER WHO PREPARE THE DRAWINGS. | | | SEE FL STATUUTES CH. 481 AND 471. ALSO | | | SEE FBC.106.1 | | | | | | 3) I SPOKE WITH JD @ TED'S SHEDS AND HE | | | TOLD ME HE WILL BE SENDING YOU THE | | | CORRECT INFORMATION IN THE MAIL. WHEN | | | YOU RECEIVE THIS INFORMATION SUBMIT TWO | | | COPIES OF THE ANCHORING DATAILS AND TWO | | | COPIES OF THE SHED DETAILS | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-01-11 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-01-11 |
Time |
06:58 |
Sent To |
E |
|
| Notes |
| 2006-01-11 00:00:00 | | | | 1) PLEASE SUBMIT THE COMPLETE FOUNDATION | | | SUPPORT AND TIE-DOWN SYSTEM FOR PLAN | | | REVIEW. | | | | | | 2) IF THE DESIGN PROFESSIONAL IS AN | | | ARCHITECT OR ENGINEER LEGALLY REGISTERED | | | UNDER THE LAWS OF THIS STATE REGULATING | | | THE PRACTICE OF ARCHITEDTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, | | | PART 1, OR ENGINEERING AS PROVIDED FOR | | | IN CHAPTER 471, SHALL AFFIX HIS OR HER | | | OFFICIAL SEAL, SIGNATURE AND DATE TO | | | SAID DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA, | | | AS REQUIRED BY FLORIDA STATUTE. | | | FBC 106.1 | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | [email protected]. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-01 |
Time |
07:23 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-03-01 |
Time |
07:00 |
Sent To |
B |
|
| Notes |
| 2006-03-01 00:00:00 | | | | NO ELECTRICAL CIRCUITS TO BE INSTALLED | | | PER OWNER, SENT TO MYRON./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-01-23 |
Time |
13:32 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2006-01-23 |
Time |
13:01 |
Sent To |
B |
|
| Notes |
| 2006-01-23 00:00:00 | | | | THE COMMENTS FROM THE PRIOR REVIEW HAVE | | | NOT BEEN ADDRESSED. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-01-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-01-12 |
Time |
15:07 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-01-12 |
Time |
15:01 |
Sent To |
PC |
|
| Notes |
| 2006-01-12 00:00:00 | | | | IF INSTALLING ELECTRICAL DEVICES IN THE | | | SHED SHOW HOW FED, DISCONNECTED PER | | | 225.31 AND GROUNDED PER 250.32. ALSO AN | | | ELECTRICAL PERMIT IS REQUIRED IF NO | | | ELECTRIC IS TO BE INSTALLED PLEASE | | | INDICATE SAME ON PLAN. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-25 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-25 |
Time |
12:49 |
Sent To |
E |
|
| Notes |
| 2006-02-25 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
12:34 |
Sent To |
E |
|
| Notes |
| 2006-01-22 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-27 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-27 |
Time |
10:52 |
Sent To |
B |
|
| Notes |
| 2005-12-27 00:00:00 | TO "MISC" BOX#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-01-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2005-12-10 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-22 |
Time |
17:27 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-22 |
Time |
17:27 |
Sent To |
I |
|
| Notes |
| 2005-12-22 00:00:00 | NOTE: SHED MUST BE A MINIMUM OF 5FT FROM | | | PROPERTY LINE. |
|
|