| Plan Review Stops For Permit 05120031 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-15 |
Time |
15:13 |
Rev Time |
1.66 |
| Received By |
alange |
Date |
2006-05-15 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-04 |
Time |
10:52 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2006-04-04 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2006-04-04 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9.ROYAL WALL ENGINEERING SHALL BE | | | DESIGNED TO THE 2004 FBC. | | | | | | ANY QUESTIONS CALL ME | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-03 |
Time |
08:56 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2006-01-03 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SUBMIT ENERGY CALCS TO THE 2004 | | | FBC. | | | | | | 4.SUBMIT TWO ORIGONAL SIGNED AND | | | SEALED SURVEYS. | | | | | | 5.SUBMIT PRODUCT APPROVALS FOR STRAPS | | | AND TIE-DOWNS. | | | | | | 6. ALL PRODUCT APPROVALS SUBMITTED SHALL | | | HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 7.BASED ON SBCCI BUILDING VALUATION | | | DATA THE PERMIT VALUATION HAS BEEN | | | REVISED TO $254,072. | | | | | | 8. R403.1.4 MINIMUM DEPTH . | | | ALL EXTERIOR FOOTINGS SHALL BE PLACED AT | | | LEAST 12 INCHES BELOW THE UNDISTURBED | | | GROUND SURFACE. | | | | | | 9. ROYAL WALL CONSTRUCTION PROCEDURE: | | | 1. ALL REQUIRED SUBMITTALS FOR SINGLE | | | FAMILY STRUCTURES ALONG WITH ENGINEERED | | | PLANS, SHOP DRAWINGS INCLUDING | | | ENGINEERING CALCULATIONS. | | | 2. LETTER FROM A LICENSED THRESHOLD | | | INSPECTOR STATING THAT AN INSPECTION | | | WILL BE MADE AT THE MANUFACTURED SITE OF | | | THE JOB SPECIFIC COMPONENTS TO VERIFY | | | CONSTRUCTION COMPLIANCE OF THE | | | COMPONENTS WITH THE ENGINEERED DESIGN. | | | | | | DURING CONSTRUCTION SUBMITTALS: | | | 1. CERTIFICATE OF COMPLIANCE AFFIDAVIT | | | FROM THE THRESHOLD INSPECTOR THAT, TO | | | THE BEST OF HIS/HER KNOWLEDGE AND | | | BELIEF, THE OFF-SITE CONSTRUCTED | | | COMPONENTS OUTLINED HEREIN AND INSPECTED | | | UNDER HIS/HER AUTHORITY HAVE BEEN | | | COMPLETED IN CONFORMANCE WITH THE | | | APPROVED PLANS, SHOP DRAWINGS AND | | | ENGINEERING. | | | | | | 10.PLEASE DO NOT ATTACHE PRODUCT | | | APPROVALS TO PLANS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-05-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-14 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-14 |
Time |
08:46 |
Sent To |
B |
|
| Notes |
| 2006-05-14 00:00:00 | NEW PLANS ADDRESSING PREVIOUS "PROVISO", | | | SUBMITTED. PLANS ARE OK AND STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
20:20 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-23 |
Time |
20:02 |
Sent To |
M |
|
| Notes |
| 2006-03-23 00:00:00 | ********** PROVISO ************ | | | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES, DUE TO | | | CHANGES IN PLANS. | | | | | | 1) NOTE: PLEASE SEE 424.3B FOR MIN OCP | | | FOR AHU #2. SHOWS 10KW HEAT WITH 45A | | | OCP. 60A MIN. | | | | | | 2)NOTE: PLEASE SEE AN "EQUIPMENT | | | GROUNDING CONDUCTOR" IS NOW BEING SHOWN | | | FROM METER TO MAIN CIRCUIT BRKR PANEL. | | | THIS PANEL IS FIRST MEANS OF DISCONNECT | | | AND THE EQUIP GRND IS ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISCONNECT. | | | 250.6,250.24B | | | | | | 3) NOTE: PLEASE SEE LOCATION OF GFI ON | | | PENINSULAR SHALL BE VERFIED, AS LOCATION | | | DOES NOT SEEM TO MEET 210.52C2, (6" OF | | | COUNTER OVERHANG). | | | | | | 4)NOTE: PLANS ARE TO REFERENCE THE 2002 | | | NFPA-70. | | | | | | ************************************** | | | PLEASE SEE THIS "PROVISO " IS TO REVISE | | | PLANS , ALONG WITH ANY OTHER REVISIONS | | | BEFORE ROUGH ELECTRICAL INSPECTION IS | | | CALLED IN. | | | IF THERE ARE ANY QUESTIONS , PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | PLEASE SEE "PROVISO", IF PLANS COME BACK | | | FOR ANY OTHER COMMENTS FROM OTHER | | | TRADES, PLEASE BE SURE TO MAKE | | | CORRECTIONS TO "PROVISO" AT THAT TIME. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-22 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-22 |
Time |
16:26 |
Sent To |
M |
|
| Notes |
| 2005-12-22 00:00:00 | **** UNSAT **** | | | | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52. PLEASE SEE REDLINED PLANS FOR | | | LOCATIONS/ | | | PLEASE ALSO VERIFY THE "LOFT" AREA, AS | | | IF THE IS CALLED A LOFT/HABITABLE RM, | | | THEN TWO ADDITIONAL RECEPTS WOULD BE | | | REQUIRED(SEE REDLINES) IF A HALL, THEN | | | THIS WOULD BE OK. | | | | | | 3)NOTE: PLEASE PROVIDE ONE ADDITIONAL | | | SD AT THIS SAME "LOFT" AREA OUTSIDE | | | BEDRMS. | | | NFPA-72 11.5.1.1 | | | | | | 4)NOTE: PLEASE LIST THE MIN REQUIRED | | | DEDICATED BATH(S) CIRCUIT(S) PER | | | 210.11C3 | | | PLEASE SEE THIS MUST BE 20A AND #12. | | | PLEASE SEE BATH RM BETWEEN BEDRMS 3 AND | | | 4, WHICH SEEMS TO SHOWS GFI, HOWEVER | | | THIS MUST BE WITHIN 3' OF SINK'S EDGE. | | | SCALE PUTS THIS CLOSE, PLEASE VERIFY. | | | | | | 5)NOTE: PLEASE MAKE REFERENCE TO THE | | | CURRENT NEC (2002) ON PLANS. | | | | | | 6)NOTE: PLEASE CORRLELATE A/C HEAT | | | STRIPS ON ELECTRICAL PLANS AND A/C | | | SHEETS. | | | PLEASE SEE BOTH UNITS SHOW 10KW HEAT ON | | | MECHANICAL, HOWEVER ONE IS SHOWN AS 5KW | | | ON PANEL SCHEDUL, YET OCP AND AWG IS | | | SHOWN FOR 10KW. | | | | | | 7)NOTE: PLEASE VERIFY LOAD CALCS, | | | PERCENTAGES AND KVA IS SHOWN, HOWEVER | | | THESE DO NOT DETAIL WHAT THEY ARE FROM. | | | 220.30, 215.5 | | | | | | 8) NOTE: PLEASE VERIFY THE RECEPT SHOWN | | | ON PENINSULAR, AS NEITHER IS SHOWN AS | | | GFI? | | | PLEASE VERIFY AS A MIN OF ONE IS | | | REQUIRED PER 210.52C3, AND GFI PER | | | 210.8A6 | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | ONE SET OF OLD/VOIDED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-23 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-23 |
Time |
11:19 |
Sent To |
M |
|
| Notes |
| 2006-05-23 00:00:00 | TO "M' BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-02 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-02 |
Time |
16:56 |
Sent To |
Z |
|
| Notes |
| 2006-05-02 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-21 |
Time |
16:56 |
Sent To |
E |
|
| Notes |
| 2006-03-21 00:00:00 | TO DP'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-22 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-22 |
Time |
09:16 |
Sent To |
E |
|
| Notes |
| 2005-12-22 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-03 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-12-05 |
Time |
09:15 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-23 |
Time |
14:06 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-05-23 |
Time |
14:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-05-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-10 |
Time |
15:50 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-10 |
Time |
15:50 |
Sent To |
E |
|
| Notes |
| 2006-05-10 00:00:00 | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 3-27-06 #2, | | | MANUAL J CALCULATIONS FOR SYSTEM TWO | | | ARE CALLING FOR 17,566 SENSIBLE BTU'S, | | | AND THE MECHANICAL PLANS FOR SYSTEM TWO | | | ARE CALLING FOR 26,400 SENSIBLE BTU'S. | | | THE PLANS CAN ONLY CALL FOR 20% MORE | | | THAN THE MANUAL J CAL'S. PER 2004 FBC | | | 13-607.1.ABC.1.1, PLEASE CORRECT. | | | | | | 2) MANUAL J CAL'S FOR SYSTEM ONE ARE | | | CALLING FOR 13,731 SENSIBLE BTU'S, AND | | | THE MECHANICAL PLANS FOR SYSTEM ONEARE | | | CALLING FOR 18,000 SENSIBLE BTU'S, AGAIN | | | THE PLANS CAN ONLY CALL FOR 20% MORE | | | THAN THE MANUAL J CAL'S (THE A/C SYSTEMS | | | ON THE PLANS ARE TO LARGE FOR THE HOUSE | | | ACCORDING TO YOUR MANUAL J CAL'S) PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-27 |
Time |
09:12 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-03-27 |
Time |
09:12 |
Sent To |
P |
|
| Notes |
| 2006-03-27 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS ARE CALLING FOR | | | 56,000 TOTAL BTU'S, AND THE MECHANICAL | | | PLANS ARE CALLING FOR 60,400 TOTAL | | | BTU'S. THE PLANS CAN NOT CALL FOR MORE | | | TOTAL BTU'S THAN THE ENERGY CAL'S, | | | PLEASE CORRECT. | | | | | | 2) MANUAL J CALCULATIONS FOR SYSTEM TWO | | | ARE CALLING FOR 17,566 SENSIBLE BTU'S, | | | AND THE MECHANICAL PLANS FOR SYSTEM TWO | | | ARE CALLING FOR 26,400 SENSIBLE BTU'S. | | | THE PLANS CAN ONLY CALL FOR 20% MORE | | | THAN THE MANUAL J CAL'S. PER 2004 FBC | | | 13-607.1.ABC.1.1, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-23 |
Time |
09:42 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2005-12-23 |
Time |
09:42 |
Sent To |
P |
|
| Notes |
| 2005-12-23 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON | | | FORM 600A-04 (2004) PER FBC 13-600.3.A . | | | | | | 2) BOTH AHU'S ARE LABELED AS AHU #2. | | | | | | 3) PLEASE SHOW LOCATION OF EACH A/C | | | DRAIN LINE TERMINATION. | | | | | | 4) MASTER SUITE RETURN AIR TRANSFER DUCT | | | IS TO SMALL (12" SUPPLY REQUIRES 15" | | | RETURN). PLEASE SEE NOTE #5. | | | | | | 5) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 6) (INFORMATIONAL) PLEASE SEE MANUAL J | | | PAGE #3 TO SEE IF A 2 1/2 TON FOR A/C | | | UNIT #2 WOULD BE MORE COMPLIANT WITH | | | 2004 FBC 13-607.1.ABC.1.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-30 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-30 |
Time |
07:39 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-23 |
Time |
12:09 |
Rev Time |
0.75 |
| Received By |
jleech |
Date |
2005-12-23 |
Time |
12:09 |
Sent To |
B |
|
| Notes |
| 2005-12-23 00:00:00 | DENIED; | | | 1.W/M TO DISCHARGE BELOW L/T, AND A C.O. | | | TO BE INSTALLED AT 48" AFF. | | | 2.W/M BRANCH DRAIN SHALL BE 3" TO TO | | | SAN. TEE. | | | 3.1/2 BATH NOT THE SAME LAY OUT AS FLOOR | | | PLAN. | | | 4.SAOARATE RISERS ARE REQUIRED FOR | | | SECOND FLOOR BATHROOMS. CAN NOT RUN INTO | | | VENT STACKS FOR FIRST FLOOR FIXTURES. | | | 5. SHEET A-1 SHOWS 2 L/T'S RISER DIAGRAM | | | SHOWS ONE, PLEASE CLARIFY. | | | 6.SECOND FLOOR BATHROOM #1 RISER DIAGRAM | | | SHOWS 2 LAV'S FLOOR PLAN SHOWS ONE. | | | PLEASE CLARIFY. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-20 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-20 |
Time |
15:01 |
Sent To |
I |
|
| Notes |
| 2006-03-23 00:00:00 | *** PLEASE SEE "PROVISO", IF PLANS COME | | | BACK FOR ANY OTHER COMMENTS, PLEASE | | | ADDRESS "PROVISO" COMMENTS AT THAT TIME. |
|
|