Plan Review Details - Permit 05120024
Plan Review Stops For Permit 05120024
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-01-03 Cont ID  
Sent By alange Date 2006-01-03 Time 08:30 Rev Time 3.25
Received By alange Date 2006-01-03 Time 07:46 Sent To  
Notes
2006-01-03 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT ENERGY CALCS TO THE 2004
 FBC.
  
 4.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS.
  
 5.SUBMIT PRODUCT APPROVALS FOR STRAPS
 AND TIE-DOWNS.
  
 6.SINGLE HUNG WINDOW AND OVERHEAD
 GARAGE DOOR SHALL HAVE THE FOLLOWING
 STATE PRODUCT APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 7.BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUATION HAS BEEN
 REVISED TO $201,302.
  
 8. R403.1.4 MINIMUM DEPTH .
 ALL EXTERIOR FOOTINGS SHALL BE PLACED AT
 LEAST 12 INCHES BELOW THE UNDISTURBED
 GROUND SURFACE.
  
 9.SIGNATURES ON PLANS SHALL BE
 ORIGONAL SIGNATURES NOT PHOTO COPY OR
 STAMPS.
  
 10. PLEASE DO NOT ATTACH PRODUCT
 APPROVAL TO PLANS.
  
 11. ROYAL WALL CONSTRUCTION PROCEDURE:
 1. ALL REQUIRED SUBMITTALS FOR SINGLE
 FAMILY STRUCTURES ALONG WITH ENGINEERED
 PLANS, SHOP DRAWINGS INCLUDING
 ENGINEERING CALCULATIONS.
 2. LETTER FROM A LICENSED THRESHOLD
 INSPECTOR STATING THAT AN INSPECTION
 WILL BE MADE AT THE MANUFACTURED SITE OF
 THE JOB SPECIFIC COMPONENTS TO VERIFY
 CONSTRUCTION COMPLIANCE OF THE
 COMPONENTS WITH THE ENGINEERED DESIGN.
  
 DURING CONSTRUCTION SUBMITTALS:
 1. CERTIFICATE OF COMPLIANCE AFFIDAVIT
 FROM THE THRESHOLD INSPECTOR THAT, TO
 THE BEST OF HIS/HER KNOWLEDGE AND
 BELIEF, THE OFF-SITE CONSTRUCTED
 COMPONENTS OUTLINED HEREIN AND INSPECTED
 UNDER HIS/HER AUTHORITY HAVE BEEN
 COMPLETED IN CONFORMANCE WITH THE
 APPROVED PLANS, SHOP DRAWINGS AND
 ENGINEERING.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-12-20 Cont ID  
Sent By btrobaug Date 2005-12-20 Time 08:00 Rev Time 0.50
Received By btrobaug Date 2005-12-19 Time 15:56 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-16 Cont ID  
Sent By adarroug Date 2005-12-16 Time 16:52 Rev Time 0.00
Received By adarroug Date 2005-12-16 Time 16:52 Sent To E
Notes
2005-12-16 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-01-03 Cont ID  
Sent By alange Date 2006-01-03 Time 08:31 Rev Time 0.00
Received By alange Date 2005-12-05 Time 09:16 Sent To  
Notes
2005-12-05 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-12-20 Cont ID  
Sent By tgordon Date 2005-12-20 Time 11:13 Rev Time 1.15
Received By tgordon Date 2005-12-20 Time 11:13 Sent To P
Notes
2005-12-20 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON
 FORM 600A-04 (2004) PER FBC 13.600.3.A .
  
 2) A/C EQUIPMENT ON MECHANICAL PLANS IS
 TO LARGE (49,400 SEN. BTU'S.). MANUAL J
 IS CALLING FOR 28,620 SEN. BTU'S + 20% =
 34,344 SEN. BTU'S.. PLEASE SEE 2004 FBC
 13.607.1.ABC.1.1.
  
 3) NO MECHANICAL DESIGN (DUCT WORK) ON
 MECHANICAL PLAN (H-1).
  
 4) NEED TO FILE A NOTICE OF
 COMMENCEMENT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-20 Cont ID  
Sent By jleech Date 2005-12-20 Time 14:01 Rev Time 1.00
Received By jleech Date 2005-12-20 Time 14:01 Sent To B
Notes
2005-12-20 00:00:00DENIED;
 SANITARY RISER DIAGRAM DOES NOT MEET
 CODE OR REFLECT FLOOR PLAN. FBC-2004
 ADMINISTRATION SEC. 106.1.1. FBC-2004
 PLUMBING CHAPTER 7 DRAINAGE AND CHAPTER
 9 VENTING THERE IS NO LAUNDRY TUB ON
 FLOOR PLAN. CHECK WITH PLUMBING
 CONTRACTOR FOR INSTALLATION HELP.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-15 Cont ID  
Sent By mmclean Date 2005-12-15 Time 11:21 Rev Time 0.00
Received By mmclean Date 2005-12-15 Time 11:21 Sent To I
Notes
2005-12-15 00:00:00DENIED,
 1. MUST MEET THE SIDE SETBACK OF 15FT
 TOTAL, WITH ONE SIDE A MINIMUM OF 5FT.
 2. MUST PROVIDE THE DIMENSION OF THE
 PROPOSED DRIVEWAY AND WALKWAY (LENGTH &
 WIDTH)
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE WITHIN THE FIRST 25FT FRONT
 SETBACK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720