Plan Review Details - Permit 05120017
Plan Review Stops For Permit 05120017
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-01 Cont ID  
Sent By alange Date 2006-03-01 Time 09:36 Rev Time 2.00
Received By alange Date 2006-03-01 Time 09:30 Sent To  
Notes
2006-03-01 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS.FS 472.025
  
 4.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR EXTERIOR DOORS, WINDOWS,
 FLAT ROOF, TILE ROOF,STRAPS AND
 TIE-DOWNS AND IMPACT PROTECTION.
  
 5.ALL PRODUCT APPROVALS SUBMITTED
 SHALL HAVE THE FOLLOWING STATE PRODUCT
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMMENDMENT TO FBC 106.3.3
  
 7.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THE 2004
 EXISTING BUILDING CODE.
 SHOW HOW BUILDING WILL COMPLY WITH THE
 SECTION SELECTED.
  
 8.SHOW SHEATHING NAILING SCHEDULE
 COMPLYING WITH FBC R-2304.9.1
  
 9.SHOW WINDOW AND DOOR PRESSURES PER
 2004 FBC CHAPTER 16.
  
 10.SHOW WALL FRAMING DETAILS INCLUDING
 HEADERS, DRAFTSTOPPING, FIRE BLOCKING
 AND METHOD OF TIE-DOWN.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 ART LANGE
 BUILIDNG PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-02-03 Cont ID  
Sent By btrobaug Date 2006-02-03 Time 15:40 Rev Time 0.50
Received By btrobaug Date 2006-02-03 Time 15:39 Sent To P
Notes
2006-02-03 00:00:00PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PROVIDE A RISER DIAGRAM FOR THE
 SERVICE, INCLUDE AIC RATING FROM
 CALCULATION PER 110.9&10.
  
 2} GFI REQUIRED PER:
 210.8(A)(2)GARAGES, AND ALSO ACCESSORY
 BUILDINGS THAT HAVE A FLOOR LOCATED AT
 OR BELOW GRADE LEVEL NOT INTENDED AS
 HABITABLE ROOMS AND LIMITED TO STORAGE
 AREAS, WORK AREAS, AND AREAS OF SIMILAR
 USE.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2006-02-03 Cont ID  
Sent By btrobaug Date 2005-12-06 Time 15:11 Rev Time 0.00
Received By btrobaug Date 2005-12-06 Time 14:46 Sent To Z
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-12-01 Cont ID  
Sent By ptjomsto Date 2005-12-01 Time 10:09 Rev Time 0.00
Received By ptjomsto Date 2005-12-01 Time 10:09 Sent To  
Notes
2005-12-01 00:00:00HISTORIC APPROVED 12/1/05 BY E BOWERS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-02 Cont ID  
Sent By adarroug Date 2006-02-02 Time 15:31 Rev Time 0.00
Received By adarroug Date 2006-02-02 Time 15:31 Sent To E
Notes
2006-02-02 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-06 Cont ID  
Sent By adarroug Date 2006-01-06 Time 16:43 Rev Time 0.00
Received By adarroug Date 2006-01-06 Time 16:43 Sent To Z
Notes
2006-01-06 00:00:00TO "Z" BOX/SUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By adarroug Date 2005-12-02 Time 14:11 Sent To  
Notes
2005-12-02 00:00:00TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-02-07 Cont ID  
Sent By tgordon Date 2006-02-07 Time 08:28 Rev Time 0.15
Received By tgordon Date 2006-02-07 Time 08:28 Sent To B
Notes
2006-02-07 00:00:00BATHROOM EXHAUST FAN ONLY.

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-02-07 Cont ID  
Sent By jleech Date 2006-02-07 Time 07:59 Rev Time 0.33
Received By jleech Date 2006-02-07 Time 07:59 Sent To M
Notes
2006-02-07 00:00:00DENIED;
 NOT ENOUGH INFORMATION. PLUMBING
 SANITARY RISER DIAGRAM REQUIRED PER.
 FBC-2004 CHAPTER 1. SEC.106.3.5.4( 9).
 PLEASE IDENIFY PLUMBING FIXTURE IN
 GARAGE.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 2 Status F Date 2006-01-31 Cont ID  
Sent By btrobaug Date 2006-02-03 Time 15:49 Rev Time 0.00
Received By mmclean Date 2006-01-31 Time 18:07 Sent To I
Notes
2006-01-31 00:00:00DENIED,
 1. MUST CHANGE THE DESCRIPTION ON THE
 APPLICATION & COMPUTER SCREEN TO REFLECT
 THE ACCESSORY STRUCTURE AS A GARAGE &
 STORAGE ONLY.
 2. CANNOT HAVE THE GARAGE & STORAGE AS A
 LIVING SPACE.
 3. MUST CHANGE THE ELECTRICAL PLANS TO
 REFLECT A STORAGE NOT A #4 BEDRROM
 (15AMP 120VOLT, 12/2) SEE PLANS FOR
 ELECTRICAL.
 4. NO COOKING FACILITY ALLOWED.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-15 Cont ID  
Sent By mmclean Date 2005-12-15 Time 09:23 Rev Time 0.00
Received By mmclean Date 2005-12-15 Time 09:23 Sent To  
Notes
2005-12-15 00:00:00DENIED,
 1. CANNOT HAVE AN ACCESSORY STRUCTURE AS
 A LIVING SPACE (ZONED SF7).
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720