| Plan Review Stops For Permit 05111207 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
P |
Date |
2009-03-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-03-04 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-03-04 |
Time |
10:04 |
Sent To |
|
|
| Notes |
| 2009-03-04 11:16:27 | ***PENDING REVISED VALUE*** | | | VALUE RECEIVED BY CONTRACTOR 3/12/9, ADJUSTED FEES | | | | | | | | | ***REVISION SUBMITTED 1/21/09**** | | | ***PARTIAL REVIEW, SHEETS 0.0, A2.0A, A2.0B, | | | A2.1A,A2.1B,A2.2A,A2.2B,A2 | | | .3,A2.5A,A2.5B,A2.6A,A2.6B,A2.7,A3.2,A4.3,A5.1,A7.0,A7. | | | 1,A14.2,A8.1,A8.3,ID9.1A,ID9.1B,ID9.2A,ID9.2B,ID9.3,ID1 | | | 0.1,ID10.3,ID11.6A,S2.5,S3.8 | | | ***PASSED W/PROVISO*** | | | | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | ****PROVISOS**** | | | | | | 1. NO DOOR PERMITTED AT SALES 101B. REVISE SHEET TO | | | REMOVE DOOR. | | | | | | 2. DOOR 154 INDICATED AT OFFICE 101A; THIS DOOR DOES | | | NOT FIT IN THIS LOCATION. PLEASE CORRELATE. | | | | | | 3. DISTANCE BETWEEN COLUMN AND RETAIL PARTS ROOM 123 | | | COUNTER IS 3'6" PER ARCHITECT (FBC11-4.2.4.1). | | | | | | 4. SUBJECT TO PLUMBING & ELECTRIC REVIEWS. | | | | | | 5. REVISED ENERGY CALCS REQUIRED PRIOR TO CERTIFICATE | | | OF COMPLETION. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
F |
Date |
2009-03-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-02-27 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-02-27 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2009-03-04 10:04:11 | ****CORRECTIONS**** | | | ****REVISION SUBMITTED 1/21/09 (PARTIAL REVIEW, ENERGY | | | CALCS ONLY)**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. THE ENERGY CALCS WERE SUBMITTED ON FORM A, WHOLE | | | BUILDING PERFORMANCE, BUT THE SQUARE FOOT AREA IS SHOWN | | | AS 34,161 (CONDITIONED AND UNCONDITIONED). THIS | | | CONFLICTS WITH ARCHITECT'S SHEET G0.0. PLEASE REVISE. | | | | | | | | 2009-02-27 13:09:23 | **PENDING RESPONSE FROM ARCHITECT** | | | EMAILED 2/27/09 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
F |
Date |
2009-02-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-02-12 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-02-12 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2009-02-12 14:10:45 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. ALL DELEGATED ENGINEERING IS TO BE REVIEWED BY | | | DESIGNER OF RECORD. FAC61G15-31. | | | | | | 2. COMBUSTIBLE MATERIAL NOT PERMITTED IN A TYPE II | | | BUILDING, SEE FBC602.2. | | | | | | 3. LOCATION NOT SHOWN FOR THE DETAILS. COMPLIANCE WITH | | | FBC TABLE 603 NOT CLEAR (DISTANCE TO PROPERTY LINE OR | | | ASSUMED PROPERTY LINE). | | | | | | 4. CHANGES TO THE PLAN ARE REVISIONS AND SHOULD BE | | | SUBMITTED AS SUCH WITH APPROPRIATE FEES PAID. PLEASE | | | NOTE THAT IT IS THE POLICY OF THIS DEPARTMENT NOT TO | | | PERFORM PLAN REVIEWS UNTIL ALL REQUIRED FEES ARE PAID. | | | A REVISION FEE HAS BEEN ADDED. PLEASE PAY IMMEDIATELY | | | AS THIS MAY DELAY INSPECTIONS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
P |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-12-17 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-12-17 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2008-12-17 11:14:12 | PREINSPECT OK PER KC | | | REVISION, FIELD REPORT CLEAR STORY WINDOW INSPECTION BY | | | DOR AND DETAIL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
F |
Date |
2008-11-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-11-25 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-11-24 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2008-11-24 12:07:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. SALES 101B, PLEASE SHOW MANEUVERING CLEARANCE FBC | | | FIGURE 11-25, PULL SIDE. THE DETAIL PROVIDED 17 A5.2 IS | | | NOT CLEAR AS TO WHAT THE OUTER BOX REPRESENTS; IS THIS | | | THE DRYWALL OVER THE COLUMN, OR SOMETHING ELSE NOT | | | SHOWN ON THE DETAIL? THIS APPEARS TO ENTIRELY OBSTRUCT | | | THE MANEUVERING CLEARANCE SPACE REQUIRED. | | | | | | 2. PROVIDE A REVISED VALUATION FOR THIS JOB. | | | | | | 3. SEE A7.0, FBC11-4.16.2. CENTERLINE OF THE FIXTURE TO | | | BE AT 18"; GENERAL MGR RESTROOM, RETAIL BOUTIQUE, MENS | | | 147, WOMENS 103 SHOW THE 18" DIMENSION REQUIRED BUT THE | | | FIXTURE IS NOT CENTERED AT THIS DIMENSION. | | | | | | 4. A7.1, PROVIDE A BACKING DETAIL. IT IS REFERENCED | | | (STATES THAT BACKING IS REQUIRED) BUT A DETAIL WHICH | | | WILL PROVIDE THE STRENGTH REQUIRED TO SUPPORT A FUTURE | | | GRAB BAR WAS NOT PROVIDED. | | | | | | 5. 1-ID11.6A, SEE 11-4.7.2; ONE COUNTER SHOWN AT 3'6", | | | DIMENSIONS NOT PROVIDED FOR OTHER COUNTERS. PLEASE | | | PROVIDE INFORMATION REGARDING USE OF THESE COUNTERTOPS | | | TO DETERMINE WHETHER OR NOT THEY SHOULD COMPLY WITH | | | FBC11-4.7.2 (36" HEIGHT FOR A PORTION OF THE | | | COUNTERTOP). | | | | | | 6. PLEASE PROVIDE A LETTER STATING THAT THE SUCCESSOR | | | ARCHITECT HAS FOLLOWED THE PROCEDURES OF FAC61G1-18.002 | | | (TAKES FULL RESPNOSIBILITY, HAS RECREATED THE WORK, | | | ETC.) OR PROVIDE NEW SIGNED AND SEALED DRAWINGS. | | | | | | IF THE ABOVE ITEMS DO NOT AFFECT OTHER TRADES, ALL OF | | | THE ABOVE ITEMS CAN BE PROVISO OR REDLINE ITEMS UPON | | | REQUEST. PLEASE CONTACT ME TO DISCUSS IF YOU WISH TO | | | REQUEST THIS OPTION. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
F |
Date |
2008-08-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-08-15 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-08-15 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2008-08-15 10:49:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | 1.PLEASE NOTE THAT, IN THE LAST REVISION, ONLY | | | CHANGES CLOUDED WERE REVIEWED.SOME OF REVISION 15 | | | WERE INCLUDED IN REVISION 14 BUT NOT CLOUDED. THEREFORE | | | SOME OF THE CHANGES WHICH WERE INADVERTENTLY PASSED | | | UNDER REVISION 14 WERE NEVER REVIEWED AND MAY HAVE | | | COMMENTS IN THIS REVIEW. | | | | | | PLEASE HAVE THE DESIGNER REVIEW THE PLANS AND CONFIRM | | | THAT ALL CHANGES (FROM THE ISSUED PERMIT SET) ARE | | | CLOUDED. | | | | | | 2.PLEASE CLARIFY ALLOWABLE BUILDING AREA AND | | | PROPOSED; SHEET G0.0 STATES THAT ALLOWABLE BUILDING | | | AREA IS 61,250 AND THE PROPOSED TOTAL AREA IS 74.967. | | | TOTAL AREA PER FLOOR SHOULD BE NOTED ON THE PLAN, AND | | | THE TOTAL PROPOSED SHOULD NOT EXCEED THE TOTAL | | | PERMITTED.PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | 3.G0.0 CODE ANALYSIS, OCCUPANT LOAD SHOULD ROUND UP, | | | NOT ROUND DOWN, AS THERE CANNOT BE A FRACTION OF A | | | PERSON, AND OCCUPANT LOAD CANNOT BE LESS THAN FBC TABLE | | | 1004. | | | | | | 4.TOTAL SF AREA IS NOT CLEAR.THE CODE ANALYSIS, | | | 33545 SF PLUS 18400SF EQUALS 51945 SF, BUT THE TOTAL | | | (BUILDING AREA BREAKDOWN) IS 74,967.PLEASE CLARIFY | | | DISCREPANCY IN BUILDING AREA. | | | | | | 5. FBC1016.3(2), DEAD END CORRIDOR IS NOT TO EXCEED 50 | | | FEET, THE CORRIDOR BETWEEN ROOMS 109 AND 113 IS SHOWN | | | AS 65 FEET. | | | | | | 6. IT APPEARS THAT NEIL EDWIN DIXON IS SUCCESSOR | | | ARCHITECT TO GERALD TODD PERRODIN.PLEASE PROVIDE A | | | LETTER WHICH STATES THAT THE PROCEDURES OUTLINED IN | | | FAC61-18.002 HAVE BEEN FOLLOWED. | | | | | | 7. THE ORIGINAL PLAN DECLARED THE BREAK ROOM AREA AS | | | BUSINESS.REVISED A2.0B SHOWS SEVERAL ASSEMBLY AREAS, | | | BUT ASSEMBLY OCCUPANCY IS NOT ADDRESSED IN THE CODE | | | ANALYSIS.PLEASE REVISE EITHER A2.0B OR G0.0. | | | | | | 8.THE RETAIL PARTS AREA IS SHOWN AS RETAIL, DO YOU | | | MEAN MERCANTILE?CODE ANALYSIS ON G0.0 REFERS TO B AND | | | S1 OCCUPANCY ONLY.SEE FBC302 AND CLARIFY OCCUPANCY | | | CLASSIFICATION. | | | | | | 9. THE TRANSMITTAL LETTER STATES THAT 300 SF WAS ADDED. | | | PLEASE REVISE THE SITE PLAN A1.0 TO REFLECT THIS | | | CHANGE, FBC*106.PLEASE PROVIDE MORE INFORMATION; THE | | | TOTAL PROPOSED AREA IS STILL SHOWN AS 74, 967, BUT THE | | | CODE ANALYSIS SHOWS AN ADDITION 300 SF. | | | | | | 10. A2.2B NOTE AT K19 STATES THAT ACCESSIBLE PARKING | | | REVISIONS ARE SHOWN ON THE CIVIL DRAWINGS.PLEASE | | | INCORPORATE THESE CHANGES INTO THIS PLAN OR PROVIDE A | | | PERMIT NUMBER.I WAS UNABLE TO LOCATE THIS CHANGE. | | | | | | 11. A7.1, THE ELEVATIONS (DETAILS 1, 2, 3, ETC.) SHOW | | | CABINET DOORS; NOT CONSISTENT WITH DETAIL 13. | | | COMPLIANCE WITH FBC11-4.24 IS NOT CLEAR. | | | | | | 12. THE STRUCTURAL CALCS ARE TO INCLUDE A TITLE BLOCK | | | ON THE SIGNED AND SEALED SHEET, FAC61G15-23.002. | | | | | | 13.IMPACT FEES MAY BE DUE TO PALM BEACH COUNTY, | | | 561-233-5025 DUE TO THE ADDITIONAL 300 SF BUSINESS | | | AREA. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-27 |
Time |
16:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-27 |
Time |
16:42 |
Sent To |
|
|
| Notes |
| 2008-06-27 16:43:05 | REVISED SHEETS G0.0, A2.0B, A2.2B, A2.5B, A2.6B, A2.7, | | | A7.0, A7.1, A8.1, A8.3, ID9.1B, ID9.2B, ID9.3, ID11.6, | | | S2.3, S3.5 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-06-19 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-06-19 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2008-06-19 15:19:36 | ****CORRECTIONS**** | | | ****REVISED 6/26/8**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.REVISION 5 DATED 5/22/06 (HAND DRAWN AND INITIALED | | | ON SHETS G0.0, A2.2B, POSSIBLY OTHER SHEETS) WAS NOT | | | INCLUDED IN THE REVISED SHEETS SUBMITTED (AND IS | | | THEREFORE APPARENTLY NON COMPLIANT).PLEASE | | | INCORPORATE THE HAND DRAWN REVISION INTO THE PLAN. | | | | | | 2.SHEET INDEX G0.0 SHOWS ONLY SHEETS AFFECTED BY | | | REVISION 14.DOES THAT MEAN THAT REVISIONS 5, 6, AND 7 | | | AFFECTED ONLY SHEETS WHICH WERE UNDER REVISION 14 ONLY | | | (AND NO SHEETS WERE REVISED THAT INCLUDED 5, 6, OR 7 | | | AND NOT 14)?ALSO, PLEASE CLARIFY IN THE RESPONSE | | | LETTER WHY REVISION NUMBERS 8 THROUGH 13 WERE NOT | | | SUBMITTED. | | | | | | 3.PROVIDE ADDITIONAL VALUE FOR THIS REVISION | | | (ADDITIONAL WORK; FLOOR SLAB POURED, ETC.). | | | | | | 4.SHEET A2.2B STATES "NEW CONCRETE SLAB THROUGHOUT | | | SERVICE CENTER.REFER TO STRUCTURAL SHEETS FOR | | | REINFORCING."I WAS UNABLE TO LOCATE THIS DETAIL ON | | | THE TWO STRUCTURAL SHEETS SUBMITTED ON THIS REVISION. | | | WAS THAT DETAIL INCLUDED IN ANOTHER STRUCTURAL SHEET | | | ALREADY SUBMITTED?SHOULDN'T THE STRUCTURAL PLAN FOR | | | THAT AREA ALSO BE SUBMITTED, SHOWING THE NEW CONCRETE | | | POUR?NOTE - IF OTHER ITEMS ARE IMMEDIATELY ADDRESSED, | | | THIS CAN BE A PROVISO ITEM. | | | | | | 5.A7.0A, DETAILS WERE REMOVED FROM THE REVISED PLAN | | | SUCH AS GENERAL MANAGER RR, PREOWNED RR, SERVICE CENTER | | | MENS RR, ETC.THESE DETAILS WERE USED TO SHOW FBC | | | CHAPTER 11 COMPLIANCE FOR THOSE AREAS.A REVISED SHEET | | | REPLACES THE OLD SHEET, SO BY REMOVING THE DETAILS FROM | | | THE NEW REVISED SHEET THESE DETAILS WOULD NO LONGER A | | | PART OF OUR PERMIT DOCUMENTS.PLEASE CLARIFY AS TO WHY | | | THESE DETAILS WERE REMOVED, OR INCLUDE THE DETAILS ON | | | THE PLAN. | | | | | | PLEASE CONTACT ME REGARDING THESE ITEMS.THE PLANS | | | HAVE BEEN PLACED ON HOLD AT MY DESK TO PREVENT A | | | POSSIBLE FAILED REVIEW FOR OTHER TRADES DUE TO THE | | | ABOVE COMMENTS. | | | | | | NEW COMMENT - | | | | | | 6.PLANS WERE HELD AT MY DESK AT | | | CONTRACTOR'S/ARCHITECT'S REQUEST FOR SEVEN DAYS PENDING | | | RECEIPT OF NEW SHEETS ADDRESSING ABOVE COMMENTS.I | | | UNDERSTAND THE CIRCUMSTANCES (ARCHITECT NO LONGER IN | | | FIRM'S OFFICE, OUTSIDE CONSULTANT); HOWEVER, AS IT | | | APPEARS THAT CONTRACTOR/ARCHITECT ARE UNABLE TO GET THE | | | NEW SHEETS AT THIS TIME, PLANS WILL BE PUT BACK ON THE | | | COMMERCIAL BOARD SO THEY WILL BE AVAILABLE FOR OTHER | | | TRADES TO REVIEW.THEY WERE HELD AT MY DESK AT THE | | | REQUEST OF PAUL FISHUK AND DAISY; WHEN NEW SHEETS WERE | | | BROUGHT IN, BUILDING WOULD THEN HAVE A PASS STATUS | | | RATHER THAN FAIL.THEREFORE, AS THE PLANS WERE NOT | | | AVAILABLE FOR OTHER TRADES TO REVIEW, IT WILL BE LIKELY | | | THAT THIS REVIEW WILL NOT MEET THE 30 DAY TARGET | | | TURNAROUND TIME. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-04-09 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-04-09 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2008-04-09 10:29:46 | REVISED ENERGY CALCS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2008-01-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-03 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-03 |
Time |
08:00 |
Sent To |
|
|
| Notes |
| 2008-01-03 08:02:35 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.PLEASE INCORPORATE CHANGES INTO THE APPROPRIATE | | | PLAN PAGES. | | | | | | IF NUMEROUS REVISIONS ARE ANTICIPATED ON THIS PROJECT, | | | PLEASE CONTACT ME REGARDING A PROCESS TO APPROVE | | | SKETCHES WITH THE REQUIREMENT TO REVISE THE PLAN FOR | | | RECORD KEEPING PURPOSES PRIOR TO THE END OF THE JOB. | | | HOWEVER, IF NUMEROUS CHANGES ARE NOT ANTICIPATED, | | | PLEASE REVISE THE PLAN SHEET AS REQUESTED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-11-14 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-11-14 |
Time |
07:13 |
Sent To |
|
|
| Notes |
| 2007-11-14 07:15:49 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | **REVISED ENERGY CALCS** | | | | | | 1.SEE ELECTRIC COMMENTS. | | | | | | 2.PLEASE CLARIFY AREA INCLUDED ON THE ENERGY CALCS. | | | THE SQUARE FOOT AREA DOES NOT CORRELATE WITH ANY OF THE | | | SQUARE FOOT AREAS ON THE PLAN. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-28 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-28 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2007-09-28 13:37:46 | REVISION 9/13/07 A2.4B | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-30 |
Time |
12:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-30 |
Time |
12:22 |
Sent To |
|
|
| Notes |
| 2007-08-30 12:24:28 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | | | | 1.)SHOP DRAWINGS ARE TO BE REVIEWED BY DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL. | | | | | | 2.)SEE SHEET S1.1, SUBMITTALS.CONFIRM THAT ENGINEER | | | HAS REVIEWED SUBMITTALS AS REQUIRED (HASAN AROURI, | | | PE). | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-23 |
Time |
17:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-23 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2006-10-23 17:25:07 | ROOF NO 06-0626.05 | | | | | | ***PROVISO***CALCULATIONS REQUIRED FOR ROOF, SEE | | | LIMITATION #7 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-07-18 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-07-17 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | FROM PREVIOUS REVIEW | | | | | | 19.)PRODUCT APPROVALS REQUIRED FOR ALL | | | COMPONENTS AND CLADDING, INCLUDING THE | | | EIFS SYSTEM, FAC9B72.FLORIDA STATE OR | | | LOCAL PRODUCT APPROVALS REQUIRED, | | | FAC9B72.WWW.FLORIDABUILDING.ORG | | | PRODUCT APPROVALS ARE TO BE REVIEWED BY | | | DESIGNER OF RECORD, FBC*106.3.3. | | | | | | THE REVIEW MAY BE DONE IN THE FORM OF A | | | SHOP DRAWING STAMP.THE STATE PRODUCT | | | APPROVAL IS NOT REQUIRED TO BE ON THE | | | PLAN. | | | | | | A CURRENT FLORIDA STATE OR LOCAL PRODUCT | | | APPROVAL IS REQUIRED, FAC9B72.IF A | | | FLORIDA STATE PRODUCT APPROVAL FOR 2004 | | | CODE IS NOT AVAILABLE FOR ANY OF THE | | | PRODUCTS, PLEASE ADVISE AND THE NOA WILL | | | BE REVIEWED FOR CODE COMPLIANCE AND IF | | | FOUND COMPLIANT, A LOCAL PRODUCT | | | APPROVAL WILL BE ISSUED. | | | | | | THE PLAN REFERS TO FL337.8 FOR THE | | | OVERHEAD DOOR, BUT THE PRODUCT APPROVAL | | | SUBMITTED WAS 742. | | | | | | THE STANLEY SLIDING DOOR IS NOT APPROVED | | | WHERE WATER INFILTRATION REQUIREMENTS | | | ARE NEEDED.THIS IS NOT A CODE | | | CORRECTION; PLEASE CONFIRM PRODUCT'S | | | CONFORMITY WITH DESIGN INTENT. | | | | | | PRODUCT APPROVALS WERE NOT SUBMITTED FOR | | | THE METAL DOORS SHOWN ON THE ELEVATIONS. | | | | | | AS DISCUSSED ON THE TELEPHONE, | | | REFERENCES TO SPECIFIC PRODUCTS ON THE | | | PLAN MAY BE ELIMINATED BY THE ARCHITECT | | | (INITIALED AND DATED) RATHER THAN | | | PRINTING NEW SHEETS. | | | | | | 22.)ID11.9, THE BREAK ROOM SINK IS TO | | | BE ACCESSIBLE, FBC11-4.24.THE CABINET | | | DOORS DO NOT ALLOW THE REQUIRED KNEE | | | CLEARANCE. | | | | | | NEW COMMENTS: | | | | | | 28.)THE ENGINEER'S SEAL IS EXPIRED | | | (SOILS REPORT).IT IS THE WRONG SIZE | | | AND SAYS "CERTIFICATE" RATHER THAN | | | "LICENSE".FAC61G15-23. | | | | | | 29.) PLEASE PROVIDE THE AREA INCREASE | | | CALCULATIONS ON THE PLAN FOR ALLOWABLE | | | AREA, SHEET G0.0. | | | | | | 30.)CLOUD ALL CHANGES.WHEN | | | RESUBMITTING, SUBMIT OLD SHEETS | | | SEPARATELY FOR REFERENCE. | | | | | | 31.)ADJACENT ACCESSIBLE PARKING IS TO | | | BE DISPERSED ACCORDING TO 11-4.6.2 (EXIT | | | 12). | | | | | | 32.)SEE ATTACHED FS553.A 4X PLAN | | | REVIEW IS REQUIRED TO BE CHARGED IF THE | | | COMMENTS ARE NOT ADDRESSED A THIRD TIME. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-16 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-03-14 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2006-03-16 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED.THE NOC PROVIDED | | | DOES NOT HAVE THE RECORDING STAMP | | | SHOWING BOOK AND PAGE. | | | | | | 2.)ENERGY CALCS ARE TO BE SIGNED AND | | | SEALED, FBC13-103.1.1.1. | | | | | | 3.)ENERGY CALCS TO BE SIGNED IN THE | | | OWNER/AGENT LINE FBC13-103.1. | | | | | | 4.)THE ENGINEERING CALCULATIONS | | | PREPARED BY TLC ARE TO INCLUDE THE CA | | | NUMBER, FAC61G15-23.002. | | | | | | 5.)ENGINEERING CALCULATIONS ARE TO BE | | | SIGNED AND SEALED ON EACH SHEET OR TO | | | HAVE AN INDEX SHEET, FAC61G15-23-002. | | | THIS HAS BEEN DISCUSSED WITH FBPE; | | | PLEASE CONTACT THEM IF YOU NEED | | | CLARIFICATION. | | | | | | 6.)THE STRESS INCREASE SHOWN ON SHEET | | | 11 OF 49 IN THE STRUCTURAL CALCS IS NOT | | | PERMITTED, FBC1605.3.1.1(2). | | | | | | 7.)SHEET 32 OF 49 OF THE STRUCTURAL | | | CALCS REFER TO ASCE7 98, SHOULD BE ASCE7 | | | 02, FBC35. | | | | | | 8.)SHEET G0.0 DECLARES THE STORAGE AND | | | AUTO REPAIR AREA AS S1 NON SEPARATED | | | USES.SEE FBC302.1.1, INCIDENTAL USES | | | SHALL BE CLASSIFIED IN ACCORDANCE WITH | | | THE MAIN OCCUPANCY OR SEPARATED FBC | | | TABLE 302.1.1, OR MIXED OCCUPANCY FBC | | | TABLE 302.3.2. | | | | | | 9.)PLANS SHOW A 2 HOUR SEPARATION | | | BETWEEN THE S1 AND B AREAS, FBC TABLE | | | 302.3.2 REQUIRES 3 HOUR. | | | | | | 10.)PROVIDE AREA CALCULATIONS ON SHEET | | | G0.00; EXISTING SF, DEMO SF, ADDITION, | | | NEW TOTAL.THIS SHOULD BE DONE PRIOR TO | | | IMPACT FEE ASSESSMENT. | | | | | | 11.)IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | | AND THE RECEIPT ATTACHED TO THE | | | APPLICATION.233-5025 FOR MORE | | | INFORMATION. | | | | | | 12.)SHEET A2.0B, NO EXIT LIGHT SHOWN | | | AT EXIT 5. | | | | | | 13.)ACCESSIBLE PARKING IS TO COMPLY | | | WITH CITY OF WEST PALM BEACH STANDARD, | | | SEE ATTACHED. | | | | | | 14.)FIRST FLOOR LIFE SAFETY PLAN SHOWS | | | THE PATH OF TRAVEL FROM PARTS INVENTORY | | | LEADING TO EXIT 9.THIS SHOULD BE | | | MEASURED TO AN ACCESSIBLE EXIT (EXIT 9 | | | SHOWS A STEP), FBC11-4.13(9).WHEN | | | MEASURED FROM FARTHER AWAY FROM THE | | | POINT SHOWN ON THE PLAN TO EXIT 7, THE | | | DISTANCE APPEARS GREATER THAN THE 200FT | | | ALLOWED. | | | | | | 15.)THE SECOND FLOOR IS REFERRED TO AS | | | BOTH A SECOND FLOOR AND A MEZZANINE. | | | FBC505, IS THIS A MEZZANINE OR A SECOND | | | FLOOR? | | | | | | 16.)IS THE COVERED OPEN AREA BETWEEN | | | THE TWO EXISTING BUILDINGS INCLUDED IN | | | THE BUILDING AREA?SEE FBC CHAPTER 2, | | | DEFINITION OF BUILDING AREA. | | | | | | 17.)DECLARE AN OCCUPANCY FOR THE OPEN | | | AREA, FBC406.SHOW REQUIRED OCCUPANCY | | | SEPARATION. | | | | | | 18.)PROVIDE A SOILS INVESTIGATION | | | REPORT, FBC1802.2.1. | | | | | | 19.)PRODUCT APPROVALS REQUIRED FOR ALL | | | COMPONENTS AND CLADDING, INCLUDING THE | | | EIFS SYSTEM, FAC9B72.FLORIDA STATE OR | | | LOCAL PRODUCT APPROVALS REQUIRED, | | | FAC9B72.WWW.FLORIDABUILDING.ORG | | | PRODUCT APPROVALS ARE TO BE REVIEWED BY | | | DESIGNER OF RECORD, FBC*106.3.3. | | | | | | 20.)FA6.0 REFERS TO A CODE FROM | | | FBC2001, REGARDING SIGNAGE.PLEASE | | | REVISE. | | | | | | 21.)CA6.0 DOES NOT SPECIFY THE 2 HOUR | | | UL LISTED BLOCK REQUIRED IN THE | | | ASSEMBLY.CHECK ALL UL DETAILS. | | | FAILURE TO DO SO WILL RESULT IN THE | | | PLANS BEING FAILED IF THEY ARE SUBMITTED | | | WITH INCORRECT INFORMATION ON OTHER | | | ASSEMBLIES. | | | | | | 22.)ID11.9, THE BREAK ROOM SINK IS TO | | | BE ACCESSIBLE, FBC11-4.24. | | | | | | 23.)PROVIDE DESIGN CRITERIA FOR | | | INTERIOR FINISHES, FBC TABLE 803.5. | | | | | | 24.)S1.1 REFERS TO ASCE7-98, SHOULD BE | | | ASCE7-02, FBC35. | | | | | | 25.)M01 REFERS TO FBC2001, SPECIAL | | | NOTES. | | | | | | 26.)M7.1 REFERS TO FBC2001.CLEARANCE | | | FOR MECHANICAL EQUIPMENT IS TO COMPLY | | | WITH FBC1509.7. | | | | | | 27.) M7.1 DETAIL 6 SHOWS WOOD BLOCKING. | | | NONCOMBUSTIBLE ONLY ALLOWED, FBC CHAPTER | | | 6. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
15 |
Status |
P |
Date |
2009-04-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-04-12 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-04-12 |
Time |
12:54 |
Sent To |
PC |
|
| Notes |
| 2009-04-12 12:54:22 | ** NOTES** | | | | | | 1) NOTE: SITE LIGHTING WORK WAS COMPLETED WITHOUT | | | PERMITS OR PLANS FOR THE SCOPE OF WORK WHICH IS ONLY | | | NOW REVISED AND PART OF THE BASE BUILDING. | | | THE SITE LIGHTING ORIGINALLY APPLIED FOR IN 2006 WAS | | | EXPIRED FOR BOTH THE MAIN SITE LIGHTING PERMIT AS WELL | | | AS THE ELECTRICAL SUB PERMIT BEFORE ACTUAL WORK WAS | | | EVER COMMENCED. NO INSPECTIONS WERE EVER SCHEDULED | | | UNDER 0611.0393 AND 06110241. | | | VALUE INCREASED ON BASE BUILDING PERMIT TO INCLUDE | | | VALUE WHICH WAS APPLIED FOR UNDER 09020126. GC IS | | | RESPONSIBLE TO SUBMIT LETTER TO CLOSE OUT 09020126 AS | | | WORK WAS TRANSFERRED TO BASE BUILDING INCLUDING FEES. | | | THE REVISED ENERGY CALCULATIONS WERE REVIEWED FOR | | | ELECTRICAL LIGHTING COMPLIANCE ONLY. ALL OTHER TRADES | | | PASSED PREVIOUS CALCULATIONS. THERE ARE NO GROSS ERRORS | | | ON LIGHTING AS STATED IN FBC CHAPTER 13. | | | ** | | | ALL SITE LIGHT POLES, STRUCTURAL AND ELECTRICAL | | | INSPECTIONS SHALL BE COMPLETED AND WORKED OUT WITH THE | | | BUILDING AND ELECTRICAL INSPECTORS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
14 |
Status |
F |
Date |
2009-02-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-02-20 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-02-20 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2009-02-20 14:04:24 | ** DENIED REVIEW ** | | | | | | | | | | | | ** THE FOLLOWING REVIEW NOTES WERE POSTED AND ARE | | | PARTIALLY ON HOLD FOR THE ISSUES BELOW AND SITE | | | LIGHTING PERMITTING ISSUES. | | | SPOKE TO DESIGNER FROM KAMM CONSULTING AT LENGTH WITH | | | RESPECT TO PERMITTING OF SITE AND THE FACT SHEETS E.01 | | | AND 5.1 WHICH ARE IN THE SETS ARE NOT THE CORRECT | | | SHEETS. | | | THE SITE LIGHTING WAS ONLY APPLIED FOR PERMIT IN | | | FEBRUARY 2009. THIS IS TWO CODE CHANGES/REVISIONS PAST | | | ORIGINAL NOVEMBER 2005 PERMIT APPLICATION DATE. | | | THE PARKING STRUCTURE WAS APPLIED FOR PERMIT IN AUGUST | | | OF 2007. IF SITE LIGHTING IS ATTACHED TO THAT STRUCTURE | | | PERMIT, LIGHTING WOULD STILL NEED TO MEET PRESCRIPTIVE | | | REQUIREMENTS OF THE LIGHTING AT THAT TIME. | | | THE ONLY WAY TO USE THE BUILDING ALLOWANCES AS TRADE | | | OFFS FOR SITE LIGHTING WOULD BE TO REVISE THE BASE | | | BUILDING PERMIT TO INCLUDE ALL SITE LIGHTING. THE SITE | | | LIGHTING WOULD MOST LIKELY EXCEED THE PRESCRIPTIVE | | | REQUIREMENTS UNDER THE CURRENT CODE OR EVEN UNDER THE | | | PRESCRIPTIVE OF 2007. KEEP IN MIND METHOD *A* IS FOR | | | WHOLE BUILDING BY DEFINITION FOR ALL KNOWN COMPONENTS | | | NOT ONLY THE ONES CURRENTLY UNDER PERMIT WITHOUT FIRE | | | WALL SEPARATION. | | | IN DOING SO THIS WOULD NOT PERMIT THE BASE BUILDING TO | | | OBTAIN A C OF C OR C OF O. ALL SITE LIGHTING WOULD NEED | | | TO BE COMPLETE BEFORE THE FINALS COULD BE COMPLETED. | | | THIS WOULD EXTEND THE 05 PERMIT UNTIL ALL WORK IS | | | COMPLETED. | | | | | | | | | ** ORIGINAL COMMENTS ON REVISIONS: BRAMAN MOTORS | | | THESE WERE GONE OVER AT LENGTH WITH DESIGNER FROM KAMM. | | | | | | | | | 1) NOTE: PLEASE SEE SHEET E0.1. THIS SHEET IS LABELED | | | FOR PHASE II SCOPE OF WORK. THIS SHEET HAS NOW BEEN | | | COMPLETELY REVISED REMOVING A SUBSTANTIAL AMOUNT OF | | | INFORMATION WHICH WAS ON PREVIOUS RECORD SET OF PLANS. | | | THERE IS NEW INFORMATION AND DETAILS. IF THIS SHEET IS | | | NOT SUPPOSE TO BE IN THIS SET WHY IS IT MARKED PHASE II | | | WHICH IS THIS PERMITTED SCOPE OF WORK? | | | WHERE IS THE ACTUAL REVISED E0.1 NEEDED? | | | THIS INFORMATION IS REQUIRED AND NEEDED ON THE PLANS IN | | | ORDER TO REVIEW FOR CODE COMPLIANCE. IT WAS THOUGHT | | | THAT PERHAPS THAT SOME OF THE PREVIOUS INFORMATION WAS | | | PLACED ON OTHER SHEETS HOWEVER THIS INFORMATION IS NOT | | | LOCATED ON ANY OF THE OTHER PLANS SUBMITTED. SEVERAL OF | | | THESE ITEMS WILL BE NOTED BELOW. | | | | | | A) THE CORRECT YEARS FOR THE CODES ARE NOW REMOVED. | | | NFPA-70, NFPA-101, NFPA-72 NOW DOES NOT HAVE ANY LISTED | | | ADOPTED EDITIONS LISTED WHICH WAS ON RECORD PLANS. | | | SHOULD BE: | | | 2002 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | | | | B) THE SHEET E0.1 IS NOW MISSING THE FIXTURE LEGEND | | | WHICH IS NEEDED TO REVIEW AND COORDINATE FIXTURES ON | | | PLANS FOR CHAPTER 13 COMPLIANCE WITH RESPECT TO ENERGY | | | CALCULATIONS. | | | THERE WERE PREVIOUS COMMENTS SPECIFIC TO THE PREVIOUSLY | | | REVISED E0.1 HOWEVER THIS SHEET NOW IN SETS DOES NOT | | | EVEN COORDINATE WITH THE RESPONSE FROM THE DESIGNER. | | | 13-415.2, 13-415.2.ABC.1.1,.1.2 AND .1.3. | | | | | | C) THE REVISED NEW SHEET E0.1 NOW HAS THE SYMBOL LEGEND | | | REMOVED. THIS IS PART OF THIS REVISED SHEET E0.1 WHICH | | | SHOULD OR SHOULD NOT BE IN THE SET. | | | | | | | | | 2) NOTE: THERE IS ALSO A REVISED/NEW SHEET E5.1 WHICH | | | IS NOT ACCURATE FOR THIS SCOPE OF WORK. IT IS LABELED | | | PHASE II WHICH IS WHAT IT IS SUPPOSED TO BE LABELED | | | HOWEVER THE SHEET DOES NOT CONTAIN THE CURRENT SCOPE OF | | | WORK. WHERE IS THE REVISED SHEET 5.1 WHICH WAS | | | ADDRESSING THE PREVIOUS COMMENTS? | | | | | | THE ACTUAL REVIEW OF SEVERAL ITEMS CAN NOT BE DONE | | | UNTIL THE REVISED PLANS ARE IN SETS FOR REVIEW. OTHER | | | SHEETS WHICH DO NOT HAVE COMMENTS AT THIS TIME SHOULD | | | BE SUBMITTED BACK WITH OTHER CORRECTED/REVISED SHEETS. | | | THESE ARE: | | | 2.1.1, 2.1.2, 3.1.1, 3.1.2, 6.1,6.2 AND 7.1. | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
13 |
Status |
F |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-08 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-08 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2008-12-08 09:11:36 | ** DENIED REVIEW OF REVISIONS ** | | | | | | | | | | | | | | | 1) NOTE: PLEASE SUBMIT COMPLETE ELECTRICAL PLANS FOR | | | ALL REVISED WORK AND SYSTEM. RESPONSE LETTER TO | | | PREVIOUS REVISIONS WHICH HAD COMMENTS STATES SEE NEW | | | PAGE E6.2 HOWEVER NO E6.2 IS IN ANY OF THE THREE SETS | | | SUBMITTED. | | | IN ORDER TO REVIEW CIRCUITING FOR NEW ITEMS ALONG WITH | | | LOADS, PANEL, ETC PLEASE SUBMIT. THIS AFFECTS THE | | | ENTIRE SET OF PLANS. | | | 240.4,310.16,408.4, 408.36 ETC | | | FBC 106.1.1 FOR CLARITY, COORDINATION OF RECORD PLANS. | | | THIS ADDITION OF THIS NEW PANEL WAS NOT ON PREVIOUS | | | REVISIONS SUBMITTED. | | | | | | 2) NOTE: PLEASE BE SURE THE LOADS ON RISER SHEET E5.1 | | | FOR MAIN #2 COORDINATE WITH THE DPA SCHEDULE ON E6.1. | | | 220. | | | FBC 106.1.1 | | | | | | 3) NOTE: ENERGY CALCULATIONS NOT STAMPED AT THIS TIME. | | | THERE ARE OPEN PERMITS WITH NEW LIGHTING ON THE | | | EXTERIOR OF BUILDING AND PARKING AREAS WHICH ARE FED | | | FROM THIS ELECTRICAL SERVICE WHICH IS NOW NEW. THE | | | RISER COTNAINS SEVERAL SUB PANELS FOR EXTERIOR SITE | | | LIGHTING YET NONE ARE LOCATED IN THE INPUT DATA REPORT. | | | PLEASE BE SURE THE CALCULATIONS ARE REVISED | | | ACCORDINGLY. | | | 13-415.2,13-415.2.ABC.1.3, 13-400.3.A | | | ** PLEASE ALSO KNOW THERE ARE OTHER ITEMS ON THE IDR | | | WHICH ARE BLANK FOR COMPONENTS WHICH ARE REQUIRED TO BE | | | PART OF THE *WHOLE BUILDING METHOD*. | | | PLEASE LOOK FOR COMMENTS FROM OTHER TRADES ON REVIEW OF | | | CALCULATIONS. | | | ** ONE EXAMPLE OF OTHER SYSTEMS IS THE IDR DO NOT | | | INDICATE ANY FLOORS? THERE ARE OTHERS. | | | | | | | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
F |
Date |
2008-07-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-31 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-31 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2008-07-31 15:43:58 | | | | | | | | | | | | | | | | ** DENIEDREVIEW ** | | | | | | 1) NOTE: PLEASE VERIFY LOCATION AND TYPE OF DEVICE FOR | | | G2 FIXTURES IN AREA BETWEEN *WRITE-UPS* AND SERVICE | | | DRIVE. | | | THIS ACCENT LIGHTING SHOWS CONTROL BY WHAT APPEARS TO | | | BE A STANDARD SINGLE POLE SWITCH BASED ON LEGEND | | | ALTHOUGH THE NOTE MENTIONS OFFICE LIGHTING. IF THIS IS | | | AN OCCUPANCY SENSOR HOW WOULD THE LOCATION OF THIS | | | DEVICE INSIDE THE OFFICE WORK FOR THE LIGHTING | | | OUTSIDE? | | | PLEASE SEE OTHER AREA AS HALLWAY OUTSIDE RORY'S OFFICE | | | WHICH SHOWS STANDARD THREE WAY SWITCH. | | | 13-415.1.ABC.1.1,.1.2,1.3. | | | | | | 2) NOTE: PLEASE GO OVER ENERGY CALCULATIONS AS THERE | | | ARE FIXTURES ON PLANS WHICH ARE NOT IN THE INPUT DATA | | | REPORT. | | | 13-415.2, 13-415.2.ABC.1.1, .1.2. | | | | | | 3) NOTE: PANEL SCHEDULES NEED TO BE REVISED TO SPECIFIC | | | ROOMS AND AREAS IN WHICH THEY FEED. | | | NEC 408.4. | | | QUOTING *LIGHTING* OR *RECEPTACLES* IS NOT ACCEPTABLE. | | | FBC 106.5, 106.1.1, 106.3.5.1.2 | | | | | | | | | | | | ** THERE ARE STILL COMMENTS FROM PREVIOUS REVIEW. | | | | | | ** IF THERE ARE ANY QUESTIONS OR IF THE COMMENTS ARE | | | NOT CLEAR IN ANY MANOR PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | | | | | | | IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-27 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-27 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2008-06-27 14:37:20 | ** REDLINED/NOTES/PROVISO ** | | | | | | 1) NOTE: PLEASE SEE NOTES FROM THE PREVIOUS *FIVE* | | | REVIEWS. AS OF THIS REVIEW THIS OFFICE STILL NEEDS | | | REVISED ENERGY CALCULATIONS SUBMITTED. MORE IMPORTANTLY | | | PLEASE BE SURE THE NEW REVISED CALCULATIONSAND ALL | | | INFORMATION ON THE INPUT DATA REPORT COORDINATES WITH | | | PLANS. | | | 13-400.0, 13-101, 13-415.2, 13-415.2.ABC.1.1, .1.2 AND | | | .1.3 | | | | | | REVIEW WILL REMAIN IN FAILED STATUS UNTIL SUCH TIME. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-04 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-04 |
Time |
15:57 |
Sent To |
PC |
|
| Notes |
| 2008-03-04 15:57:34 | ** DENIEDREVIEW ** | | | | | | 1) NOTE: PLEASE SEE THE COMMENTS FROM REVIEW DATED | | | 3/4/08 FOR ENERGY CALCULATIONS ARE STILL IN NEED OF | | | ADDRESSING. CAN NOT VERIFY CODE COMPLIANCE OF | | | ELECTRICAL PLANS AT THIS TIME FOR COORDINATION OF ALL | | | LIGHTING AND CONTROLS. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
F |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-04 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-04 |
Time |
15:55 |
Sent To |
M |
|
| Notes |
| 2008-03-04 15:55:57 | ** DENIEDREVIEW ** | | | | | | ** PLEASE SEE COMMENTS FROM THE PREVIOUS REVIEW ARE | | | STILL IN NEED OF ADDRESSING. | | | | | | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS REVIEW WHICH | | | REQUESTED THE INPUT DATA REPORT ON THE ENERGY | | | CALCULATIONS TO CORRELATE WITH PLANS. | | | ** PLEASE SEE FOR EXAMPLE FIXTURE L2 AS THE IDR ONLY | | | SHOWS ONE FIXTURE YET THE PLANS SHOWS SEVERAL MORE THAN | | | THIS. | | | PLEASE SEE 13-415.1.A, 13-400.3.A | | | *2004 FBC 2.11 VERSION IS OK HOWEVER ALL LIGHTING ON | | | PLANS NEEDS TO COORDINATE WITH THE CALCULATIONS. | | | ** ENERGY CALCULATIONS BEING ROUTED TO MECHANICAL AND | | | BUILDING REVIEWERS. | | | | | | 2) NOTE: ENERGY CALCULATIONS ARE NOT SUBMITTALS. OWE | | | REVISION FEE OF $60, RECEIPT ATTACHED. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2008-01-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-14 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-14 |
Time |
12:08 |
Sent To |
M |
|
| Notes |
| 2008-01-14 12:08:48 | ** DENIED REVISIONS** | | | | | | 1) NOTE: PLEASE BE SURE THE SUBMITTED ENERGY | | | CALCULATIONS COORDINATE WITH THE ELECTRICAL PLANS AS | | | SUBMITTED. | | | FOR EXAMPLE: PLEASE SEE THE INPUT DATA REPORT CONTAINS | | | NO EXTERIOR LIGHTING YET THE PLANS CLEARLY DO INDICATE | | | EXTERIOR LIGHT FIXTURES IN SEVERAL LOCATIONS. | | | 13-415.2.ABC.1.3 | | | PLEASE ALSO SEE THE METHOD OF CALCULATIONS IS NOT FROM | | | THE CODE WHICH PROJECT WAS APPLIED UNDER. | | | PLEASE KNOW THE 2.5 VERSION AS SUBMITTED WAS NOT IN | | | EFFECT UNTIL DECEMBER 8TH, 2006. | | | PLEASE SEE 13-400.3. | | | VERSION IS BASED ON PERMIT APPLICATION DATE WHICH WAS | | | NOV OF 2005. | | | PLEASE BE SURE THE OWNER?S AGENT IS SIGNED ON | | | CERTIFICATION SHEET. | | | | | | ** PLEASE BE SURE TO ADDRESS COMMENTS. IF THERE ARE ANY | | | QUESTIONS, ANY COMMENTS NOT TYPED IN A CLEAR MANOR OR | | | NOT UNDERSTOOD IN ANYWAY PLEASE DO NOT HESITATE IN | | | CONTACTING THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
F |
Date |
2007-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-23 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-23 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2007-12-23 09:55:42 | ** DENIEDREVISION ** | | | | | | | | | 1) NOTE: PLEASE SEE NOTES GIVEN ON NOVEMBER 9TH, 2007 | | | WHICH REQUIRES REVISED ENERGY/PERFORMANCE CALCULATIONS | | | PER 13-415.2. | | | PLEASE KNOW THESE ARE REQUIRED. | | | PLEASE BE SURE ALL LIGHTING ON PLANS CORRELATES WITH | | | THE LIGHTING PERFORMANCE CALCULATIONS/ENERGY | | | CALCULATIONS. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-09 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-09 |
Time |
09:24 |
Sent To |
M |
|
| Notes |
| 2007-11-09 09:27:21 | ** DENIED** | | | | | | | | | 1) NOTE: PLEASE SUBMIT REVISED ENERGY CALCULATIONS WITH | | | COORDINATION OF ALL LIGHTING FIXTURES ON PLANS AND | | | FIXTURES LEGEND FOR WATTAGE, NUMBER OF FIXTURES AND | | | METHOD OF CONTROL. | | | PLEASE SEE 13-415.1.A, 13-415.2. | | | | | | 2) NOTE: FLAT REVISION FEE OF $60 IS DUE AS REVISED | | | ENERGY CALCULATIONS IS NOT A SUBMITTAL. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTIONS SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
N |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-09 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-06 |
Time |
16:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-31 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-31 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2006-12-31 15:01:42 | STAMPED ELECTRICAL SHEETS | | | STAMPED REVISED ENERGY CALCULATIONS. | | | VOIDED OLD EN CALCS AND PLACED WITH PACKAGE TO GO BACK | | | TO CONT. | | | | | | ** WILL STILL NEED A NEW RECORDED NOTICE OF | | | COMMENCEMENT RECORDED WITHIN 90DAYS PRIOR TO ISSUANCE | | | OF PERMIT. FS 713.13(2). |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-26 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-26 |
Time |
19:10 |
Sent To |
|
|
| Notes |
| 2006-10-26 20:07:35 | *** UNSAT 3RD REVIEW *** | | | | | | 1) NOTE: PLEASE SEE PLANS AS THERE ARE AREAS WHERE | | | LIGHTING OVER RIDE CONTROLS ARE MISSING. PLEASE SEE | | | AREAS NOT NOTED IS DEVICE NOT SHOWN AS "S OC" ETC. | | | PLEASE SEE SOME OF THESE ARE RED-LINED, BATH RM, MEN'S/ | | | WOMEN'S(TWO SETS) SEC'S OFFICE, PARTS, PARTS | | | RECEIVING,, OFFICE BATH, STORAGE ETC. | | | PLEASE SEE 13-415.1.AB.1, WHICH SPEAKS OF TABLES IN | | | 415.2. | | | PLEASE SEE PERFORMANCE CALCULATIONS WERE NOT LOCATED IN | | | SETS. SHEET 7.1 MENTIONS TO SEE ENERGY CALCULATIONS, | | | HOWEVER PLEASE SEE 13-415.2.ABC.1. PLEASE SEE CODE | | | WHICH SPEAKS OF CERTAIN TRADES OFF NOT PERMITTED. | | | PLEASE SEE LIGHTING LEVELS SHALL BE PER TABLE SIN | | | 415.2.C.1, OR 415.2.B.1. ASPLANS APPEAR TO BE MORE OF | | | A SPACE BY SPACE, THIS MAY BE DONE ON PLANS ON A | | | "TABLE" OF SORTS INDICATING THE AREAS ,PERMITTED LPD | | | PER SQ FT. PLEASE SEE THE LEVELS AS SHOWN ON 7.1 DO NOT | | | APPEAR TO CORRELATE MAX PERMITTED IN THE TABLES. | | | PLEASE SEE SOME AREAS CAN BE DONE PER 13-415.2.B.2 | | | | | | PLEASE SEE METHOD "A" SHOWS ALL MANUAL ? ON/OFF? | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-25 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-25 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2006-06-25 00:00:00 | IN ELEC | | | *** UNSAT 2ND REVIEW *** | | | | | | 1) NOTE: PLEASE SEE NOTE #1 FROM | | | PREVIOUS REVIEW AS PLANS PREVIOUSLY CAME | | | IN UNDER THE 2001 DESIGN. IT WAS | | | REQUESTED TO SEE 2004 FBC FOR DESIGN AS | | | THE CODE HAD CHANGED ON OCT 1ST, 2005 TO | | | THE NEW CODE. | | | PLEASE SEE HAVE NOW COME BACK AND | | | RESPONSE MENTIONS ALL DESIGNS ARE NOW | | | UNDER THE 2004 FBC. | | | PLEASE SEE FBC CHAPTER 13 REQUIREMENTS | | | COULD NOT BE LOCATED IN DESIGN/OR ON | | | PLANS. | | | PLEASE PROVIDE WORST CASE VOLTAGE DROP | | | PER 13-413.1ABC.1 | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND | | | .1.3 FOR LIGHTING CONTROLS REQUIRED. | | | PLEASE INDICATE THE NEW SYSTEM BEING | | | USED, SCHEDULING, OVER-RIDES DEVICES, | | | LOCATIONS, AND THE TIMES OF OVER-RIDES | | | DEVICES, DEPENDING ON INSTALLATION AND | | | TYPE OF DEVICES INSTALLED. | | | PLEASE SEE13-415.1.ABC.3, | | | PLEASE SEE 13-415.1.AB.1 FOR MIN | | | CALCULATIONS FOR LIGHTING LEVELS AND | | | DENSITIES (LPD)TO BE PROVIDED. | | | PLEASE SEE 13-415.2.ABC.1, AND SPECIFY | | | METHOD AND TABLES. (415.2.C.1,415.2.B.1 | | | | | | ** THE FOLLWING IS NOT A KAMM CONSULTING | | | ENG'S COMMENT. | | | | | | 2) NOTE: PLEASE SEE LANDSCAPE PLANS AS | | | THE FIRM "KILDAY AND ASSOCIATES" IS | | | MISSING THE REQUIRED INFORMATION ON | | | TITLE BLOCKS AS SET-FORTH IN THE FAC | | | 61G1-16.004 | | | PLEASE SEE MISSING THE PRINTED NAME AND | | | LICENSE NUMBER OF THE LANDSCAPE ARCH. | | | PLEASE SEE MISSING CERTIFICATE OF | | | AUTHORIZATION NUMBER AS REQUIRED PER FS | | | 481.319. | | | | | | 3) NOTE: PLEASE SEE THE RECORDED NOTICE | | | OF COMMENCMENT SUBMITTED HAS EXPIRED PER | | | FS 713.13(2). PLEASE KNOW, IF WORK HAS | | | NOT COMMENCED WITH IN 90 DAYS OF | | | RECORDING NOC, THEN THE NOC WILL BECOME | | | "VOID" AND WILL BE REQUIRED TO BE RE- | | | RECORDED. PLEASE KNOW, THE NOC IS ONLY | | | REQUIRED BEFORE PICKING UP PERMIT. | | | | | | 4) NOTE: PLEASE BE SURE TO "COMPLETELY | | | REMOVE" ALL OLD/VOIDED SHEETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. PLEASE | | | ONLY SUBMIT ONE COPY OF THE OLD/VOIDED | | | REMOVED SHEETS SEPARATELY FOR REFERENCE. | | | | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER | | | TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-31 |
Time |
19:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-31 |
Time |
19:14 |
Sent To |
I |
|
| Notes |
| 2005-12-31 00:00:00 | IN ELEC FOR REVIEW | | | ********* UNSAT ********** | | | | | | 1)NOTE: PLANS SHOULD INCLUDE CURRENT | | | CODES RELEVANT TO PLANS/DESIGN AND SCOPE | | | OF WORK. | | | PLEASE KNOW, AS OF OCT 1ST, 2005 THE FBC | | | HAS CHANGED TO THE 2004 FBC WITH OTHER | | | ADOPTED CODES. | | | PLEASE HAVE PLANS REFLECT THE 2002 | | | NFPA-70(NEC). | | | 2003 NFPA-101 , 2002 NFPA-72. | | | PLEASE SEE OTHER REVIEWER(S) NOTES. | | | | | | 2)NOTE: PLEASE PROVIDE INFORMATION FOR | | | OPERATION OF NEW GATES IN THE EVENT OF | | | POWER FAILURE. PLEASE ALSO SEE POSSIBLE | | | FIRE DEPT NOTES PERAINING TO MIN WIDTHS | | | REQUIRED . | | | | | | 3)NOTE: PLEASE SEE 230.2(C) FOR OTHER | | | SERVICES PERMITTED. PLEASE PROVIDE | | | INFORMATION FOR EXISTING SERVICE SIZE, | | | AS THE SAME VOLTAGES APPEAR TO BE | | | PRESENT. PLEASESECOND SERVICE NEEDS TO | | | BE VERIFIED FOR GRANTING ANY SPECIAL | | | PERMISSION FOR ADDING SERVICE. IT IS | | | NOTED THAT THE EXISITNG MAIN AND NEW | | | MAIN WILL BE GROUPED IN THE SAME | | | LOCATION. | | | | | | 4)NOTE: PLEASE SEE LS 101 7.8,700.6 , | | | 90.4 AN EMERGENCY BATTERY BACK UP | | | FIXTURE OF SOME TYOE IS BEING REQUESTED | | | TO BE ADDED TO MAIN ELECTRICAL ROOM | | | UNLESS ONE IS ALREADY PRESENT. | | | | | | 5)NOTE: PLEASE SEE MIN FEEDER SIZES FOR | | | PANELS SRA, SRB AND GA SHALL BE SIZED | | | PER 310.16. 3/0'S RATED AT 200A'S (75 | | | DEGREE COL) AND OCP IN NEW DPA IS SHOWN | | | AT 225A'S. 4/0'S MIN. | | | 240.4,310.16,110.14 | | | | | | 6)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AND LARGEST MOTOR LOADS AT 125%. | | | PLEASE SHOW ON EACH PANEL AND ON MAIN | | | SERVICE CALCS. | | | 215.3,230.42 ETC. | | | | | | 7)NOTE: PLEASE SPECIFY ALL AREAS IN | | | SERVICE BAYS PER NEC 511, 511.7 A,B ETC. | | | PLEASE PROVIDE A LAYOUT AND SPECS FOR | | | ALL ELECTRICAL DEVICES, LIGHTING ETC. | | | ** PLEASE SEE NOTES PERTAINING TO MIN | | | AIR CHANGES PER OTHER REVIEWERS. | | | PLEASE SEE NEW ELECTRICAL PANELS SHOWN | | | IN THESE AREAS ALSO, MIN HEIGHTS ETC, | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REIVEWERS WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRCIAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-02-03 |
Time |
15:56 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2006-02-03 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
8 |
Status |
P |
Date |
2009-03-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-03-10 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-03-10 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2009-03-10 13:47:50 | REVISIONS STAMPED E2.1.1 AND E2.1.2. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
F |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-12-10 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-12-10 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2008-12-10 15:12:49 | *****REVISION #16, DATED 10/13/2008, PARTIALLY | | | APPROVED***** | | | | | | | | | REVISED PLAN SHEETS A2.0A & A2.0B, A2.3, AND A8.3 WERE | | | STAMPED, INITIALED, AND DATED; SHEETS ID91A & ID9.1B | | | AND E2.1.1 & E2.1.2 TO BE FIRE-STAMPED WHEN THE | | | BUILDING AND ELECTRICAL EXAMINERS' COMMENTS HAVE BEEN | | | ADDRESSED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-08-07 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-08-07 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2008-08-07 11:01:03 | REVISION DATED 6/3/08 STAMPED LS SHEETS A2.0A AND | | | A2.0B. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
P |
Date |
2008-06-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-06-30 |
Time |
10:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-06-30 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2008-06-30 10:21:42 | REVISED SHEETS THAT DON'T APPEAR TO HAVE DIRECT IMPACT | | | ON FIRE PROTECTION SYSTEMS AND LIFE SAFETY. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-01-02 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-01-02 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2008-01-02 11:27:27 | REVISION TO FAO.1 AND FA2.1.2 DATED 11/30/07. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-13 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-13 |
Time |
16:29 |
Sent To |
B1 |
|
| Notes |
| 2007-12-13 16:35:09 | *****UNSAT***** | | | | | | | | | 1.INCORPORATE CHANGES/REVISION PLAN SHEETS SO THAT | | | REVIEWER(S) IS/ARE ABLE TO GET A FULL VIEW OF THE | | | PROJECT. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-09-13 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-09-13 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-09-13 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-01-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-10 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-10 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2006-01-10 00:00:00 | ******DENIED****** | | | | | | 1) PLEASE SHOW ALL HYDRANT LOCATIONS ON | | | OKEECHOBEE BLVD OR SOUTH OF THE | | | PROPERTY. | | | | | | 2) PLEASE PROVIDE INFORMATION FOR GATE | | | CONTROL DEVICES AND INDICATE FAIL SAFE | | | OPERATION IN EVENT OF POWER FAILURE. | | | | | | 3) CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 4) PLEASE INDICATE THE INTERIOR FINISH | | | CLASSIFICATION FOR WALLS AND CEILINGS IN | | | TERM OF CLASS A, B, OR C. | | | | | | 5) PLEASE PROVIDE PRESCRIPTIVE STRENGTH | | | REQUIREMENTS FOR HANDRAILS AND GUARDS. | | | | | | 6) AN ADDRESS IS REQUIRED ON BUILDING | | | AND SHALL BE A MINIMUM OF 6" IN HEIGHT | | | AND CONTRASTING WITH THE BACKGROUND. | | | | | | 7) PLEASE PROVIDE MANUFACTURER SPEC | | | SHEETS REGARDING FIRE RESISTANCE FOR | | | PROPOSED CANOPY. | | | | | | 8) THE MIDDLE EXIT DOOR ON THE EAST SIDE | | | OF THE SERVICE CENTER SHOWS EQUIPMENT IN | | | FRONT OF IT THAT WOULD APPEAR TO BE AN | | | OBSTRUCTION FOR EXITING. | | | | | | 9) A KNOX BOX IS REQUIRED ON BUILDING. | | | | | | 10) DUCT SMOKE DETECTORS SHALL INITIATE | | | A GENERAL FIRE ALARM IN ACCORDANCE WITH | | | LOCAL REQUIREMENTS. | | | | | | 11) AS PLANS INDICATE, SEPARATE SHOP | | | DRAWINGS AND PERMITS ARE REQUIRED FOR | | | FIRE SPRINKLER AND FIRE ALARM SYSTEMS. | | | | | | 12) FIRE EXTIGUISHERS TO BE MOUNTED AT | | | DISTANCES TO SATISFY THE 75' TRAVEL | | | DISTANCE REQUIREMENT. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2009-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-10 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-10 |
Time |
16:23 |
Sent To |
P |
|
| Notes |
| 2009-04-10 16:23:36 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2009-04-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-04-03 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-04-03 |
Time |
14:48 |
Sent To |
E |
|
| Notes |
| 2009-04-03 14:49:12 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2009-02-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-02-11 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-02-11 |
Time |
11:28 |
Sent To |
B |
|
| Notes |
| 2009-02-11 11:28:40 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2009-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2009-01-23 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2009-01-23 |
Time |
11:53 |
Sent To |
|
|
| Notes |
| 2009-01-23 11:53:48 | TO "COMM" BD#41/PLANS ON RACK--2 ROLLS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2008-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-10 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-10 |
Time |
10:36 |
Sent To |
B |
|
| Notes |
| 2008-12-10 10:36:23 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2008-11-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-13 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-13 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2008-11-13 16:15:31 | TO "COMM" BD#33 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-04 |
Time |
11:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-04 |
Time |
11:12 |
Sent To |
P |
|
| Notes |
| 2008-08-04 11:12:43 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-11 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-11 |
Time |
14:25 |
Sent To |
P |
|
| Notes |
| 2008-07-11 14:26:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-11 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-11 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2008-07-11 12:36:34 | TO "COMM" BD#3/PLANS ON RACK/1 ROLL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-29 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-29 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2008-05-29 16:34:20 | TO "COMM" BD#38 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-21 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-21 |
Time |
08:38 |
Sent To |
E |
|
| Notes |
| 2008-02-21 08:39:06 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-21 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-21 |
Time |
08:26 |
Sent To |
B |
|
| Notes |
| 2008-02-21 08:26:51 | TO "E" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-09 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-09 |
Time |
10:59 |
Sent To |
E |
|
| Notes |
| 2008-01-09 11:00:16 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-19 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-19 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2007-12-19 17:22:08 | TO "COMM" BD#49 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-13 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-13 |
Time |
08:56 |
Sent To |
FIRE |
|
| Notes |
| 2007-12-13 13:29:58 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-22 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-22 |
Time |
09:48 |
Sent To |
E |
|
| Notes |
| 2007-10-29 09:28:55 | TO DP DESK (ENERGY CALCS) | | 2007-10-22 09:49:14 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-10 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-10 |
Time |
15:41 |
Sent To |
B |
|
| Notes |
| 2007-10-10 15:41:22 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-10-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-02 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-02 |
Time |
11:37 |
Sent To |
M |
|
| Notes |
| 2007-10-02 11:37:34 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-27 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-27 |
Time |
09:54 |
Sent To |
B |
|
| Notes |
| 2007-09-27 09:55:11 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
08:57 |
Sent To |
B |
|
| Notes |
| 2007-08-21 08:57:43 | TO "SHILL" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-08 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-08 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2006-12-31 14:13:49 | TO COMM BOARD #63 12/31 | | 2006-12-14 09:31:12 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-04 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-04 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2006-10-19 13:23:31 | TO "COMM" BD#34/PLANS ON RACK | | 2006-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-12 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-12 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-14 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-01 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2006-01-05 00:00:00 | TO "COMM" BD#40 | | 2005-12-02 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
11 |
Status |
P |
Date |
2008-12-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-12-06 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-12-06 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2008-12-06 10:33:39 | REVISED M2.1.1, M2.1.2, M6.1 AND ENERGY CALCS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
P |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-29 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-29 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2008-07-29 16:57:35 | REVISION 15 M2.1.1, M2.1.2, M6.1 NEED SIGNED AND SEALED | | | SYSTEM SIZING SUMMARY ATTACHED TO REVISED ENERGY | | | CALCULATIONS IF ELECTRICAL REVIEW IS OK IN ACCORDANCE | | | WITH FBCB 13-407.1.ABC.1(1) |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-27 |
Time |
11:27 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-27 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2008-06-27 11:17:25 | REVISED M2.1.1, M2.1.2, M6.1 REV.14 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-04-09 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-04-09 |
Time |
09:41 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2008-01-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-01-18 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-01-18 |
Time |
11:39 |
Sent To |
PC |
|
| Notes |
| 2008-01-18 13:19:41 | NO MECHANICAL CHANGES TO REVISED ENERGY CALCULATIONS. | | | HOWEVER, THE INCORRECT FORM HAS BEEN SUBMITTED. BASED | | | ON DATE OF PERMIT APPLICATION, THE CORRECT FORM IS | | | 400A-04 V2.11. PLEASE CORRECT AND RESUBMIT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-01-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-01-08 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-01-08 |
Time |
14:42 |
Sent To |
PC |
|
| Notes |
| 2008-01-08 15:18:18 | REV 11 PAGE M2.1.2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-11-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-10 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-10 |
Time |
12:38 |
Sent To |
B |
|
| Notes |
| 2007-11-10 12:55:13 | ENERGY CALCS REVISED/RESTAMP OK |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-10-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-10-20 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-10-20 |
Time |
17:50 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-11-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-11-02 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-11-02 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2006-11-02 07:11:57 | PASSED 08-01-06 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-01 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-31 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-02-03 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-02-03 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2006-02-03 00:00:00 | DENIED:2004 FLORIDA BUILDING CODE | | | | | | 1.PLAN SHEET M2.1.2, 16 X 14 RETURN | | | AIR DUCT INTO LOCKER ROOM #145 | | | PENETRATES RATED RATED WALL BETWEEN THE | | | LOCKER ROOM & SERVICE CENTER, NO FIRE | | | DAMPER IS INDICATED.PLEASE CLARIFY. | | | | | | 2.EQUIPMENT SCHEDULE INDICATES RTU 14 | | | & 15 (SERVICE GARAGE).THE EQUIPMENT | | | SCHEDULE INDICATES A TOTAL OF OUTSIDE | | | AIR 1040 CFM.PER 2004 FMC 404.2 | | | MINIMUM VENTILATION SHALL BE .05 CFM PER | | | SQAURE FOOT & THE SYSTEM SHALL BE | | | CAPABLE OF PRODUCING A VENTILATION RATE | | | OF 1.5 CFM PER SQUARE FOOT. | | | | | | 3.PLAN SHEET M2.2.2, PLEASE CLARIFY | | | THE 'VEHICLE EXTRACTION SYSTEM FAN BY | | | OTHERS'.WILL THIS HOOK-UP TO THE | | | INDIVIDUAL MUFFLER EXHAUST? | | | | | | 4.PLAN SHEET M8.1 SEQUENCE OF | | | OPERATION ITEM 4 INDICATES THE GARAGE | | | DOORS WILL BE NORMALLY CLOSED.IS THIS | | | CORRECT? | | | | | | 5.RTU-14 & RTU-15 WILL BE | | | RECIRCULATING AIR FROM THE SERVICE AREA. | | | PLEASE SHOW COMPLIANCE WITH 2004 FBC | | | 406.6. | | | | | | 6.PLEASE CLARIFY IF THE ALARMS FOR THE | | | CO & FV SENSORS ARE TIED TO THE FIRE | | | ALARM. | | | | | | 7.PLEASE PROVIDE SUBMITTAL FOR THE | | | FLAMMABLE VAPOR SENSOR & THE CARBON | | | MONOXIDE SENSOR.PLEASE NOTE, TESTING | | | OF SENSORS REQUIRED FOR FINAL | | | INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
13 |
Status |
P |
Date |
2009-04-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-04-13 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-04-13 |
Time |
18:15 |
Sent To |
|
|
| Notes |
| 2009-04-13 18:16:27 | REVISIONS OK -- SHTS GO.O, P2.1.1, P2.1.2, P3.1.1, | | | P3.1.2 & P5.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
12 |
Status |
F |
Date |
2009-03-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-03-11 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-03-11 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2009-03-11 13:43:41 | DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | A. NOTE: AS INDICATED PREVIOUSLY, TURN OFF ALL | | | PREVIOUSLY APPROVED REVISION CLOUDS AND REVISION | | | NUMBERS. THIS ADDS MUCH TIME TO THE REVIEW PROCESS AND | | | CONFUSES THE REVIEW PROCESS AS SOME NEW REVISIONS ARE | | | NOT APPARENT AND SOME REVISIONS SHOW A CLOUD AND A | | | REVISIONS NUMBER BUT NO APPARENT REVISION IS SHOWN. | | | ONLY SHOW THE NEW REVISION CLOUDS AND REVISIONS NUMBERS | | | FOR REVISIONS BEING CHANGED ON THIS SUBMITTAL. PLEASE | | | TURN OFF ALL PREVIOUS REVISIONS. SECTION 106.1.3. | | | | | | 1. SHT P2.1.1 SHOWS 4 DRINKING FOUNTAINS, BUT ONLY ONE | | | ACCESSIBLE DRINKING FOUNTAIN. PER SECTION 11-4.1(10)(B) | | | 50% OF ALL PROVIDED DRINKING FOUNTAINS SHALL BE | | | ACCESSIBLE. PLEASE INDICATE THE TWO REQUIRED DRINKING | | | FOUNTAINS. | | | | | | 2. SHT P2.1.1 REVISION 16B WAS NOT FOUND ON THE FLOOR | | | PLAN. PLEASE CORRELATE. -- THE PIPING TO THE 3 LAVS IN | | | THE WOMENS TOILET ROOM HAS BEEN REVISED WITH NO CLOUD | | | OR REVISION NUMBER. PLEASE SHOW CLOUDS AND REVISION | | | NUMBERS FOR ALL REVISIONS SUBMITTED. SECTION 106.1.3. | | | | | | 3. SHT P2.1.2 PLANS ARE NOT LEGIBLE BETWEEN COL. LINES | | | 10-11/F-O. ALSO MANY REVISION NUMBER 16'S SHOWN ON THE | | | FLOOR PLAN ARE NOT INDICATED IN THE REVISION INDEX. | | | SOME REVISIONS 16B & 17 SHOW NO CHANGES TO THE | | | PLUMBING. PLEASE CLARIFY. SECTIONS 106.1.2 & 106.1.3. | | | | | | 4. SHT P3.1.1 SHOWS 2 REVISION NUMBER 5 THAT WERE NOT | | | ON PREVIOUS REVISION SHEET SIGNED, SEALED ON JULY 28, | | | 2008. IF THESE ARE NEW REVISION THEN NEW REVISION | | | NUMBERS ARE REQUIRED. SECTION 106.1.3. -- REVISION | | | NUMBER 17 AT ROOM 104 SHOWS NO PLUMBING REVISION. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 5. SHT P3.1.2 NO CHANGES WERE FOUND WITHIN THE CLOUDS | | | FOR REVISIONS 16/16B/17. PLEASE CLARIFY. SECTIONS | | | 106.1.1 & 106.1.3. | | | | | | 6. SHT P5.1 MANY REVISION NUMBERS SHOW NO | | | CHANGE/REVISION TO THE PLANS WITHIN THE CLOUDED AREA. | | | PLEASE CLARIFY WHAT IS REVISED IN EACH CLOUDED AREA. | | | SECTION 106.1.1. REVISION 17 SHOWS A CAPPED HUB DRAIN. | | | PER SECTION 704.5 DEAD ENDS ARE PROHIBITED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
P |
Date |
2009-03-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-03-11 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-03-11 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2009-03-11 12:08:31 | REVISION OK -- SHT P0.1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
F |
Date |
2008-12-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-16 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-16 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2008-12-16 11:17:13 | REVISIONS DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P0.1 REVISIONS ON FILE FOR PUBLIC RECORD SHOW | | | REVISION 15 DATED 6-11-08 & REVISION 16 DATED 7-25-08. | | | SHT P0.1 SUBMITTED FOR REVIEW ON 11-12-08 HAS DELETED | | | REVISION 15 FROM THE REVISION INDEX AND SHOWS REVISION | | | 16 WITH A NEW DATE OF 10-31-08. THIS IS NOT APPROVED. | | | ALL REVISIONS SUBMITTED PREVIOUSLY FOR PUBLIC RECORD | | | SHALL BE MAINTAINED IN THE REVISION INDEX AND ON THE | | | FLOOR PLAN UNTILL CHANGED WITH NEW CLOUDS AND REVISION | | | NUMBERS. SECTION 106.1.3. | | | | | | 2. SHT P2.1.1 SHOWS 2 DRAINLINES TO THE SINGLE DRINKING | | | FOUNTAIN OUTSIDE THE TOILET ROOMS ADJACENT TO COL. LINE | | | "B". PLEASE CLARIFY. WILL THERE BE TWO DRINKING | | | FOUNTAINS? SECTION 106.1.1. | | | | | | 3. SHT P2.1.2 REVISIONS ON FILE FOR PUBLIC RECORD SHOW | | | REVISION 15 DATED 6-11-08. SHT P2.1.2 SUBMITTED FOR | | | REVIEW ON 11-12-08 HAS DELETED REVISION 15 FROM THE | | | REVISION INDEX. THIS IS NOT APPROVED. ALL REVISIONS | | | SUBMITTED PREVIOUSLY FOR PUBLIC RECORD SHALL BE | | | MAINTAINED IN THE REVISION INDEX AND ON THE FLOOR PLAN | | | UNTILL CHANGED WITH NEW CLOUDS AND REVISION NUMBERS. | | | SECTION 106.1.3. | | | | | | 4. SHT P3.1.1 REVISIONS ON FILE FOR PUBLIC RECORD SHOW | | | REVISION 15 DATED 6-11-08. SHT P3.1.1 SUBMITTED FOR | | | REVIEW ON 11-12-08 HAS DELETED REVISION 15 FROM THE | | | REVISION INDEX. THIS IS NOT APPROVED. ALL REVISIONS | | | SUBMITTED PREVIOUSLY FOR PUBLIC RECORD SHALL BE | | | MAINTAINED IN THE REVISION INDEX AND ON THE FLOOR PLAN | | | UNTILL CHANGED WITH NEW CLOUDS AND REVISION NUMBERS. | | | SECTION 106.1.3. | | | | | | 5. SHT P3.1.2 REVISIONS ON FILE FOR PUBLIC RECORD SHOW | | | REVISION 15 DATED 6-11-08. SHT P3.1.2 SUBMITTED FOR | | | REVIEW ON 11-12-08 HAS DELETED REVISION 15 FROM THE | | | REVISION INDEX. THIS IS NOT APPROVED. ALL REVISIONS | | | SUBMITTED PREVIOUSLY FOR PUBLIC RECORD SHALL BE | | | MAINTAINED IN THE REVISION INDEX AND ON THE FLOOR PLAN | | | UNTILL CHANGED WITH NEW CLOUDS AND REVISION NUMBERS. | | | SECTION 106.1.3. | | | | | | 6. SHT P5.1 REVISIONS ON FILE FOR PUBLIC RECORD SHOW | | | REVISION 15 DATED 6-11-08. SHT P5.1 SUBMITTED FOR | | | REVIEW ON 11-12-08 HAS DELETED REVISION 15 FROM THE | | | REVISION INDEX. THIS IS NOT APPROVED. ALL REVISIONS | | | SUBMITTED PREVIOUSLY FOR PUBLIC RECORD SHALL BE | | | MAINTAINED IN THE REVISION INDEX AND ON THE FLOOR PLAN | | | UNTILL CHANGED WITH NEW CLOUDS AND REVISION NUMBERS. | | | SECTION 106.1.3. | | | | | | 7. SHT P5.1 DOMESTIC WATER ISOMETRIC DOES NOT REFLECT | | | THE FLOOR PLAN AS IT DOES NOT SHOW THE WATER SUPPLY FOR | | | THE NEW W/C ADDED TO THE MEN'S TOILET ROOM ADJACENT TO | | | COL. LINE 'B'. PLEASE CORRELATE. SECTION 106.1.1. | | | | | | 8. SHT P5.1 SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | | FLOOR PLAN AS IT SHOWS 3 LAVS UPSTREAM OF THE 3 URINALS | | | IN THE MEN'S TOILET ROOM ADJACENT TO COL. LINE 'B'. | | | PLEASE CORRELATE. SECTION 106.1.1. | | | | | | 9. IN ORDER TO EXPEDITE THE REVISIONS SUBMITTED, PLEASE | | | SHUT OFF ALL PREVIOUSLY REVIEWED CLOUDS AND NUMBERED | | | TRIANGLES FROM EACH SHEET. THIS IS AN ONGOING REQUEST | | | SO THAT ALL CLOUDED AREAS ARE NOT RE-REVIEWED | | | NEEDLESSLY. THANK YOU SECTION 106.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
P |
Date |
2008-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-07 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-07 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2008-08-07 15:59:01 | REVISIONS OK--SHTS P0.1, P2.1.1, P2.1.2, P3.1.2 & | | | P5.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
F |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-28 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-28 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2008-07-28 15:31:57 | REVISIONS DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.1.1 REVISIONS NOT CLOUDED BY MATCH LINE ALONG | | | COLUUM LINE 10.--IDENTIFY NEW FIXTURES IN THE | | | TOILET ROOM. THERE IS NO SANITARY SHOWN TO THESE | | | FIXTURES. SECTION 106.1.3. | | | | | | 2. SHT P2.1.2 MANY REVISIONS/CHANGES ARE NOT INDICATED | | | WITH A CLOUD NOR REVISION NUMBER.--REVISION 15 | | | BETWEEN COLUUMS F-H/1-3 DOES NOT INDICATE | | | CHANGE/REVISION FROM FILE SET OF PLANS. PLEASE | | | CLARIFY. | | | | | | 3. SHT P3.1.1 IDENTIFY NEW FIXTURES IN THE TOILET | | | ROOMS.--NOT FIXTURES ARE SHOWN WHERE HDF/DF IS | | | INDICATED. PLEASE SHOW ALL FIXTURES. SECTION 106.1.3. | | | | | | 4. SHT P3.1.2 MANY REVISIONS NOT CLOUDED NOR INDICATED | | | WITH A REVISION NUMBER. SECTION 106.1.3. | | | | | | 5. SHT P5.1 MANY REVISIONS ARE NOT CLOUDED NOR | | | INDICATED WITH A REVISION NUMBER. SECTION 106.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
P |
Date |
2008-07-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-28 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-28 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2008-07-28 15:24:48 | REVISION OK--SHT P0.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
F |
Date |
2008-07-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-23 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-23 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2008-07-23 15:38:46 | REVISIONS DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. SHTS P2.1.1, P2.1.2, P3.1.1, P3.1.3 & P5.1 SHOWS | | | REVISION #15 ON THE FLOOR PLAN, BUT NO REVISION #15 | | | SHOWN ON THE REVISION INDEX IN THE TITLE BLOCK. PLEASE | | | CORRELATE. SECTION 106.1.3.--ALSO TURN OFF THE | | | CLOUDS AND REVISION NUMBERS ON THE FLOOR PLANS FROM | | | PREVIOUSLY APPROVED REVISIONS TO HELP EXPEDITE THE PLAN | | | REVIEW PROCESS. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | 2. SHT P2.1.1 DRINKING FOUNTAINS SHALL NOT BE INSTALLED | | | IN PUBLIC RESTROOMS PER SECTION 410.2.--WHERE MORE | | | THAN ONE DRINKING FOUNTAIN IS PROVIDED ON A FLOOR, AT | | | LEAST 50% OF THOSE PROVIDED SHALL COMPLY WITH SECTION | | | 11-4.15 AND BE ON AN ACCESSIBLE ROUTE. SECTION | | | 11-4.1(10)(B). PLEASE INDICATE ALL ACCESSIBLE DRINKING | | | FOUNTAINS. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | 3. SHT P2.1.2 THERE ARE CHANGES/REVISIONS ON THE PLANS | | | THAT ARE NOT CLOUDED OR NUMBERED AS A REVISION. PLEASE | | | CLOUD AND NUMBER ALL REVISIONS TO BE SUBMITTED. SECTION | | | 106.1.3. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | 4. SHT P5.1 WATER ISOMETRIC. THE LAV RELOCATED IN THE | | | ACCESSIBLE STALL STILL SHOWS THE HOT WATER SUPPLY TO | | | LAV IN THE PREVIOUS LOCATION. PLEASE CLARIFY. SECTION | | | 601.1. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | 5. SHT P5.1 WATER ISOMETRIC. THE SINK ADDED BEHIND THE | | | SHOWER IS INDICATED AS A SHOWER FIXTURE, (SH-1). PLEASE | | | CLAIRFY.--PLEASE NUMBER THE REVISION CLOUD FOR SAME | | | FIXTURE. SECTION 106.1.1. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | 6. SHT P5.1 WATER ISOMETRIC. THE SUPPLY LINE TO THE 3 | | | LAVS IN THE WOMEN'S TOILET ROOM SHOWS NO CONNECTION TO | | | THE WATER MAIN IN THE CEILING. PLEASE SHOW WHERE THE | | | SUPPLY LINE CONNECTS TO WATER MAIN, (2"). SECTIONS | | | 106.1.1 & 601.1. | | | ****RESPONSE NOTED, COMMENT NOT ADDRESSED. | | | | | | ***********NEW COMMENT*********** | | | | | | 1B. NEW REVISIONS SUBMITTED HAVE THE SAME DATE ON THE | | | SEALED PLANS AS THE PREVIOUS REVISIONS SUBMITTED. NO | | | CHANGES FROM THE PREVIOUS REVISION SUBMITTAL. ONE COPY | | | OF THE ORIGINAL REVISION AND ONE COPY OF THE LATEST | | | REVISION HAVE BEEN RETAINED AS WELL AS THE COMMENT | | | REPLY FROM THE DESIGN PROFESSIONAL. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
F |
Date |
2008-07-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-07-02 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-07-02 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2008-07-02 11:07:15 | REVISIONS DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHTS P2.1.1, P2.1.2, P3.1.1, P3.1.3 & P5.1 SHOWS | | | REVISION #15 ON THE FLOOR PLAN, BUT NO REVISION #15 | | | SHOWN ON THE REVISION INDEX IN THE TITLE BLOCK. PLEASE | | | CORRELATE. SECTION 106.1.3.--ALSO TURN OFF THE | | | CLOUDS AND REVISION NUMBERS ON THE FLOOR PLANS FROM | | | PREVIOUSLY APPROVED REVISIONS TO HELP EXPEDITE THE PLAN | | | REVIEW PROCESS. | | | | | | 2. SHT P2.1.1 DRINKING FOUNTAINS SHALL NOT BE INSTALLED | | | IN PUBLIC RESTROOMS PER SECTION 410.2.--WHERE MORE | | | THAN ONE DRINKING FOUNTAIN IS PROVIDED ON A FLOOR, AT | | | LEAST 50% OF THOSE PROVIDED SHALL COMPLY WITH SECTION | | | 11-4.15 AND BE ON AN ACCESSIBLE ROUTE. SECTION | | | 11-4.1(10)(B). PLEASE INDICATE ALL ACCESSIBLE DRINKING | | | FOUNTAINS. | | | | | | 3. SHT P2.1.2 THERE ARE CHANGES/REVISIONS ON THE PLANS | | | THAT ARE NOT CLOUDED OR NUMBERED AS A REVISION. PLEASE | | | CLOUD AND NUMBER ALL REVISIONS TO BE SUBMITTED. SECTION | | | 106.1.3. | | | | | | 4. SHT P5.1 WATER ISOMETRIC. THE LAV RELOCATED IN THE | | | ACCESSIBLE STALL STILL SHOWS THE HOT WATER SUPPLY TO | | | LAV IN THE PREVIOUS LOCATION. PLEASE CLARIFY. SECTION | | | 601.1. | | | | | | 5. SHT P5.1 WATER ISOMETRIC. THE SINK ADDED BEHIND THE | | | SHOWER IS INDICATED AS A SHOWER FIXTURE, (SH-1). PLEASE | | | CLAIRFY.--PLEASE NUMBER THE REVISION CLOUD FOR SAME | | | FIXTURE. SECTION 106.1.1. | | | | | | 6. SHT P5.1 WATER ISOMETRIC. THE SUPPLY LINE TO THE 3 | | | LAVS IN THE WOMEN'S TOILET ROOM SHOWS NO CONNECTION TO | | | THE WATER MAIN IN THE CEILING. PLEASE SHOW WHERE THE | | | SUPPLY LINE CONNECTS TO WATER MAIN, (2"). SECTIONS | | | 106.1.1 & 601.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-01-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-22 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-20 |
Time |
18:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-11-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-11-22 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-11-22 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2006-11-22 14:34:12 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT GO.O CODE ANALYSIS, FIXTURE COUNT INDICATES 5 | | | DRINKING FOUNTAINS PROVIDED. ONLY 3 DRINKING FOUNTAINS | | | ARE LOCATED. PLEASE CLARIFY. 2 SERVICE SINKS ARE | | | INDICATED AS BEING PROVIDED. ONLY 1 SERVICE SINK IS | | | LOCATED. PLEASE CLARIFY. TABLES 1004.1.2 & TABLE | | | 403.1. | | | | | | 2. SHT P5.1 DOMESTIC WATER ISOMETRIC. THE TWO WATER | | | CLOSETS AND ACCESSIBLE LAV FOR THE MEN'S TOILET ROOM, | | | (102), ARE NOT INDICATED ON THE WATER RISER DIAGRAM. | | | PLEASE CORRELATE THE RISER WITH THE FLOOR PLAN. SECTION | | | 106.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-15 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-15 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2006-07-15 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | UNSAT | | | PREVIOUS COMMENT DATED 3-4-06 #8 | | | | | | NO DOORS ON BASE OF CABNET. | | | | | | | | | 8. BREAK ROOM SINK SHALL COMPLY WITH | | | 11-4.24 AND ALL SUBSECTIONS. | | | SUBMIT A DETAIL SHOWING COMPLIANCE. | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | D. 11-4.24.5 CLEAR FLOOR SPACE | | | | | | (FORWARD APPROACH, EXTENDING A MAXIMUM | | | OF 19" UNDERNEATH THE SINK REQUIRED). | | | | | | E. 11-4.24.6 EXPOSED PIPES AND SURFACES | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-03-04 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-02-28 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2006-03-04 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 11 | | | | | | 1. SHT A2.4B INDICATE VERTICAL | | | CONTRIBUTION TO EXISTING ROOF BY | | | EXTENDING PARAPET ABOVE EXISTING. | | | (ADJACENT TO ROOF AREA "A"). SHOW ADDED | | | SQUARE FOOTAGE. - ALSO INDICATE THE | | | METHOD OF SECONDARY ROOF DRAINAGE FOR | | | THE EXISTING ROOF BETWEEN COL. LINES F | | | THRU L, AND 3 THRU 9 WHERE NEW ROOF IS | | | LOCATED. SECTION 1107. | | | 2. SHT A2.4B MORE INFORMATION IS | | | REQUIRED ON THE ROOF DRAINS. IS THE | | | UPPER ROOF DRAINING DOWN TO THE LOWER | | | ROOF AREAS "I" & "H", OR ARE THOSE | | | OVERFLOW SCUPPERS NEAR COL LINES "Q-15", | | | "M-15", & "I-15"? PLEASE CLARIFY. | | | SECTION 106.1.1. | | | 3. SHT A2.4B ROOF AREAS F, E, C, B, & A. | | | STATE "SCUPPERS PER FIG. 1617.3" THAT IS | | | IN THE HIGH VELOCITY HURRICANE ZONE AND | | | IS APPROVED IN DADE/BROWARD COUNTYS | | | ONLY. SCUPPERS SHALL BE SIZED BY | | | SECTIONS 1101.7, 1107.3 AND TABLE | | | 1106.7. THE SIZING OF THE SCUPPERS CAN | | | NOT BE DETERMINED WITH OUT REFERENCE TO | | | THE DEFLECTION OF THE ROOF. PLEASE | | | INDICATE THIS IN YOUR SIZING | | | CALCULATIONS FOR THE SCUPPERS ON THE | | | PLANS. | | | 4. SHT A7.2 PLUMBING FIXTURES SCHEDULE | | | AND RESTROOM ACCESSORIES SCHEDULE ITEM | | | NUMBERS ARE NOT INDICATED ON ANY DETAIL. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | 5. ACCESSIBLE LAVS: INDICATE COMPLIANCE | | | WITH 11-4.19.4 EXPOSED PIPES AND | | | SURFACES. | | | 6. SUBMIT A DETAIL FOR THE ACCESSIBLE | | | SHOWER SHOWING: | | | GRAB BARS PER FIGURE 37. 11-4.21.4 | | | SHOWER UNIT PER FIGURE 37. 11-4.21.6 | | | CURBS PER SECTION 11-4.21.7 | | | 7. SHT A7.0 GENERAL MANAGERS RESTROOM | | | SHALL BE ADAPTABLE AND AS SUCH IT MUST | | | SHOW A 5' TURNING AREA, BACKING FOR THE | | | GRAB BARS AT THE WATER CLOSET & SHOWER, | | | AS WELL AS A DETAIL FOR THE SHOWER | | | SHOWING THE LOCATION OF THE CONTROLS AND | | | INDICATE NO CURB ON THE SHOWER. SHOW THE | | | OPENING DIMENSIONS FOR THE WATER CLOSET | | | BETWEEN THE SHOWER AND THE VANITY FOR | | | THE LAV. | | | 8. BREAK ROOM SINK SHALL COMPLY WITH | | | 11-4.24 AND ALL SUBSECTIONS. SUBMIT A | | | DETAIL SHOWING COMPLIANCE WITH: | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD | | | APPROACH, EXTENDING A MAXIMUM OF 19" | | | UNDERNEATH THE SINK REQUIRED). | | | E. 11-4.24.6 EXPOSED PIPES AND SURFACES | | | F. 11-4.24.7 FAUCETS | | | 9. SHT P0.1 PLUMBING NOTES: #1 | | | REFERENCES FBC-2001. ADOPTED CODE IS | | | FBC-2004. PLEASE CHANGE REFERENCE AND | | | DESIGN PER 2004 CODE. | | | 10. SHT P0.1 WATER HEATER DETAIL. | | | THERMAL EXPANSION CONTROL IS REQUIRED | | | PER SECTION 607.3.2. INDICATE METHOD. | | | 11. SHT P2.1.2 STORM OVERFLOW DRAIN LINE | | | WITH 10,900SF SHALL BE MINIMUM 10" PER | | | TABLE 106.3. PLEASE INDICATE ALL PIPE | | | SIZES AND SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM. | | | 12. SHT P2.1.2 NOTE "COMPRESSED AIR | | | DROPS BY OTHERS". SEPARATE PLANS AND | | | PERMIT REQUIRED FOR COMPRESSED AIR | | | SYSTEM. INDICATE MATERIAL TYPE FOR | | | COMPRESSED AIR ON PLANS. (SPECIALTY | | | DRAWINGS NOT SUBMITTED). | | | 13. SHT P2.2.2 LOWER ROOF (SHOWN AS 80SF | | | ON ARCHITECTURAL SHEETS) STORM DRAINAGE | | | PIPING IS NOT SHOWN. PLEASE SUBMIT STORM | | | PIPING FOR ROOF. PLEASE SUBMIT STORM | | | ISOMETRIC RISER DIAGRAMS FOR ALL | | | SECTIONS OF THE STORM SYSTEM SHOWING ALL | | | PIPE SIZES, CLEANOUTS, AND SQUARE | | | FOOTAGE AS IT ACCUMULATES IN THE SYSTEM | | | INCLUDING OVERFLOW SYSTEMS. SECTION | | | 106.3.5.1.3. | | | 14. SHT P5.1 DOMESTIC WATER RISER | | | DIAGRAM. WATER HAMMER ARRESTORS SHALL BE | | | LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING AS | | | SHOWN. PDI-WH 201 AND MANUF. INSTALL. | | | INSTRUCTIONS. (SEE PLUMBING NOTE #13 SHT | | | P0.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-11-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-11-01 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-11-01 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-07-10 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-07-10 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | PARKING DETAIL ON SIMONS & WHITE SHEET 3 | | | OF 3 DOES NOT SHOW WHEEL STOP LOCATION | | | MEETING CODE - 2 FEET FROM BACK OF WHEEL | | | STOP TO END OF PARKING SPACE IS | | | REQUIRED. | | | | | | A DIAGRAM SHOWING WPB STANDARD IS | | | ATTACHED TO THE NOTES IN THE BERMIT | | | PACKAGE. | | | | | | CONTACT ERIC SCHNEIDER (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2006-04-14 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2006-04-14 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2006-04-14 00:00:00 | 1) ENGINEERING AND SITE PLANS DO NOT | | | MATCH THE LANDSCAPE PLAN. | | | | | | 2) THE APPROVED PLANS STATE THAT THE NEW | | | AND RELOCATED AREA EQUALS 6,004 SQ. FT. | | | THE ENGINEERING PLANS SHOW 2 NEW | | | ADDITIONS TOTALING 8,118 SQUARE FEET. | | | | | | 3) THE ADDITION ON THE NORTH SIDE OF THE | | | BUILDING DOES NOT MEET THE DIMENSIONS OR | | | LAYOUT AS SHOWN ON THE APPROVED PLANS | | | (INCLUDES ADJACENT SIDEWALK). | | | | | | 4) THERE IS NOT THE REQUIRED 24 FOOT | | | WIDE DRIVE AISLE BETWEEN THE ADDITION ON | | | THE NORTH SIDE OF THE BUILDING AND THE | | | 90 DEGREE PARKING SPACES LABELED AS | | | ?SERVICE PARKING? ON THE ENGINEERING | | | PLAN. | | | | | | 4) THE ADDITION ON THE SOUTH SIDE OF THE | | | BUILDING DOES NOT MEET THE DIMENSIONS OR | | | LAYOUT AS SHOWN ON THE APPROVED PLANS | | | (INCLUDES ADJACENT SIDEWALK, PARKING, | | | LANDSCAPING AND SIGNAGE). | | | | | | 5) THE VEHICLE DISPLAY, ACCESSIBLE PATH, | | | LOCATION OF THE PYLON SIGN, PAVER AREAS | | | AND DRIVEWAY ACCESS POINTS ARE DIFFERENT | | | DO NOT MEET THE DIMENSIONS OR LAYOUT AS | | | SHOWN ON THE APPROVED PLANS. | | | | | | 6) THE SITE PLAN INCLUDED WITH THE | | | BUILDING PERMIT LISTS 5 HANDICAP PARKING | | | SPACES PROVIDED WHILE THE PLANS SHOW 6 | | | HANDICAP SPACES. | | | | | | 7) THE PLANS LIST THE MAIN SHOWROOM | | | BUILDING AS CONTAINING 53,368 SQ. FT. | | | WHILE THE ?PARKING REQUIRED? TABLE LISTS | | | ONLY 45,378 AS COUNTED TOWARD THE | | | REQUIRED PARKING.THE ?PARKING | | | PROVIDED? TABLE DOES NOT ACCURATELY OR | | | COMPLETELY LIST THE PARKING PROVIDED. | | | NOTE - IT APPEARS THAT THE SITE HAS | | | EXCESS PARKING. | | | | | | 8) THE PARKING DETAIL INCORRECTLY SHOWS | | | THE WHEEL STOP LOCATION.THE CITY | | | REQUIRES THE WHEEL STOP TO BE LOCATED | | | TWO FEET FROM THE END OF THE PARKING | | | SPACE. | | | | | | 9) THE ADA LOGO SHALL BE NO MORE THAN 24 | | | INCHES FROM THE OPENING OF THE HANDICAP | | | PARKING SPACE. | | | | | | 10) THE FUTURE LAND USE AND ZONING | | | DESIGNATIONS ARE INCORRECT ON THE | | | LANDSCAPE PLAN (PBC DESIGNATIONS USED). | | | | | | CONTACT ERIC SCHNEIDER @ (561)822-1435. |
|
|