Plan Review Details - Permit 05111165
Plan Review Stops For Permit 05111165
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-08-25 Cont ID  
Sent By mjacobs Date 2006-08-25 Time 14:31 Rev Time 0.00
Received By mjacobs Date 2006-08-25 Time 14:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-05-23 Cont ID  
Sent By mjacobs Date 2006-05-23 Time 12:08 Rev Time 0.00
Received By mjacobs Date 2006-05-23 Time 11:39 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-03-22 Cont ID  
Sent By mjacobs Date 2006-03-22 Time 14:05 Rev Time 0.00
Received By mjacobs Date 2006-03-20 Time 08:04 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-06 Cont ID  
Sent By mjacobs Date 2006-03-06 Time 10:07 Rev Time 3.00
Received By mjacobs Date 2006-03-06 Time 07:03 Sent To PC
Notes
2006-03-04 00:00:001)CITY OF WPB AMENDMENTS.106.3.3
 PRODUCT APPROVALS. THOSE PRODUCTS WHICH
 ARE REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.THESE ITEMS
 INCLUDE EXTERIOR DOORS, WINDOWS,ALL
 ROOFING PRODUCTS,STRUCTURAL
 COMPONENTS, ETC.TWO COPIES OF EACH IS
 REQUIRED ALONG WITH THE STATE COVER
 SHEET AND FL#. THE ONLY PRODUCT APPROVAL
 SUBMITTED IS FOR THE EXTERIOR
 DOOR.
  
 2) INDICATE THE HIEGHT AND WIDTH
 DIMENTIONS OF THE NEW PORCH. ALSO
 INDICATE THE LOWEST HEADROOM OF THE
 PORCH.SEE WPB AMENDMENTS 106.1.1
  
 3)MORE INFORMATION IS REQUIRED FOR THE
 HURRICANE STRAPS. WHAT'S THE UP-LIFT
 PRESSURES OF THESE STRAPS? THIS
 INFORMATION IS REQUIRED ON THE DRAWINGS.
  
 4) SHEET A2.1 REFERS TO CERTAIN
 DETAILS,BUT THERE ARE NO REFERENCE
 NUMBERS IN THE SYMBOL.
  
 5) TRUSS DRAWINGS SHALL PE BROVIDED TO
 THE BUILDING OFFICIAL AND APPROVED PRIOR
 TO INSTALLATION. R802.10.1
  
 6) THE FINISH SCHEDULE ON SHEET A2.1
 INDICATES ALL CEILING HEIGHT AT 9'. HOW
 WILL THIS BE ACCOMPLISH IF THE
 DIMENTIONS ON SHEET A2.3 ARE USED.
 INDICATE THE CORRECT FINISH CEILING
 HEIGHT OF EACH ROON ON THE DRAWINGS.
 SEE R305.1 FOR ADDITIONAL INFORMATION.
  
 7) ON SHEET A2.3 DRAWING #2, THE 3/4"
 SCALE DOES NOT REFLECT THE CORRECT
 DIMENTIONS.CLARIFY.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-01-25 Cont ID  
Sent By mjacobs Date 2006-01-25 Time 14:40 Rev Time 0.00
Received By mjacobs Date 2006-01-25 Time 15:24 Sent To PC
Notes
2006-01-20 00:00:001) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 2) 106.3.3* PRODUCT APPROVALS- 2004
 THOSE PRODUCTS THAT ARE RGULATED BY DCA
 RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITTING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL. THESE ITEMS
 INCLUDE EXTERIOR DOORS, WINDOWS, ROOFING
 PRODUCTS, SHUTTERS, STRUCTURAL
 COMPONENTS,ETC.
  
 3) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS&CONDITIONS
 OF THE BUILDING PERMIT.
  
 4) FBC 2309.6ACCESS TO ATTIC SPACE
 EACH ATTIC SPACE WITH A CLEAR HEIGHT OF
 24" OR GREATER SHALL BE PROVIDED WITH AN
 INTERIOR ATTIC ACCESS OPENING NOT LESS
 THAN 20"X 36".
  
 5) TRUSS DRAWINGS SHALL BE PROVIDED TO
 THE BUILDING OFFICIAL AND APPROVED PRIOR
 TO INSTALLATION.SEE R802.10.1
 FOR ADDITIONAL INFORMATION.
  
 6) WINDOW AND DOOR BUCKS SHALL EXTEND
 BEYOUD THE INTERIOR FACE OF THE WINDOW
 OR DOOR FRAME SUCH THAT FULL SUPPORT OF
 THE FRAME IS PROVIDED. SEE R613.6.2
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561) 805-6726
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-07-31 Cont ID  
Sent By btrobaug Date 2007-07-31 Time 09:09 Rev Time 0.00
Received By btrobaug Date 2007-07-31 Time 07:09 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-01-02 Cont ID  
Sent By btrobaug Date 2007-01-02 Time 14:12 Rev Time 0.50
Received By btrobaug Date 2007-01-02 Time 13:20 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-12-15 Cont ID  
Sent By adarroug Date 2006-12-28 Time 15:58 Rev Time 0.50
Received By btrobaug Date 2005-12-15 Time 17:30 Sent To M
Notes
2005-12-15 00:00:00 
  
  
 PROVISO
  
 RESUBMIT CORRECTED PANEL SCHEDULE PRIOR
 TO ROUGH INSPECTIONS INDICATING
 COMPLIANCE WITH 210.52(C)(1) FOR THE
 BATH AND 210.12 FOR THE ARC FAULT
 REQUIREMENTS.
  
 ALLOW AT LEAST A WEEK FOR THE REVISION
 TO CLEAR PLAN REVIEW BEFORE YOU WILL BE
 ABLE TO SCHEDULE AN INSPECTION.
  
 IF THERE ARE ANY QUESTIONS PLEASDE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2006-08-22 Cont ID  
Sent By ssherman Date 2006-08-22 Time 10:01 Rev Time 0.00
Received By ssherman Date 2006-08-22 Time 10:01 Sent To  
Notes
2006-08-22 00:00:00HISTORIC APPROVAL PER JILLIAN PAPA

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-11-30 Cont ID  
Sent By ptjomsto Date 2005-11-30 Time 12:31 Rev Time 0.00
Received By ptjomsto Date 2005-11-30 Time 12:31 Sent To  
Notes
2005-11-30 00:00:00HISTORIC APPROVED 11/30/05 BY E BOWERS

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-07-30 Cont ID  
Sent By adarroug Date 2007-07-30 Time 11:07 Rev Time 0.00
Received By adarroug Date 2007-07-30 Time 11:07 Sent To E
Notes
2007-07-30 11:08:14TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-01-12 Cont ID  
Sent By adarroug Date 2007-01-12 Time 16:57 Rev Time 0.00
Received By adarroug Date 2007-01-12 Time 16:57 Sent To M
Notes
2007-01-12 17:00:26TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-12-28 Cont ID  
Sent By adarroug Date 2006-12-28 Time 15:57 Rev Time 0.00
Received By adarroug Date 2006-12-28 Time 15:57 Sent To E
Notes
2006-12-28 15:58:04TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-08-24 Cont ID  
Sent By adarroug Date 2006-08-24 Time 11:55 Rev Time 0.00
Received By adarroug Date 2006-08-24 Time 11:55 Sent To B
Notes
2006-08-24 00:00:00TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-05-22 Cont ID  
Sent By adarroug Date 2006-05-22 Time 12:54 Rev Time 0.00
Received By adarroug Date 2006-05-22 Time 12:54 Sent To B
Notes
2006-05-22 00:00:00TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-05-05 Cont ID  
Sent By adarroug Date 2006-05-05 Time 13:11 Rev Time 0.00
Received By adarroug Date 2006-05-05 Time 13:11 Sent To Z
Notes
2006-05-05 00:00:00TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-03-14 Cont ID  
Sent By adarroug Date 2006-03-14 Time 14:28 Rev Time 0.00
Received By adarroug Date 2006-03-14 Time 14:28 Sent To B
Notes
2006-03-14 00:00:00TO "MJACOBS" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-02-22 Cont ID  
Sent By adarroug Date 2006-02-22 Time 11:09 Rev Time 0.00
Received By adarroug Date 2006-02-22 Time 11:09 Sent To M
Notes
2006-02-22 00:00:00TO "M" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-15 Cont ID  
Sent By adarroug Date 2006-02-15 Time 11:18 Rev Time 0.00
Received By adarroug Date 2006-02-15 Time 11:18 Sent To Z
Notes
2006-02-15 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-14 Cont ID  
Sent By adarroug Date 2005-12-14 Time 10:21 Rev Time 0.00
Received By adarroug Date 2005-12-14 Time 10:21 Sent To E
Notes
2005-12-14 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-01-25 Time   Rev Time 0.00
Received By adarroug Date 2005-12-02 Time 08:43 Sent To  
Notes
2005-12-02 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-01-16 Cont ID  
Sent By tgordon Date 2007-01-16 Time 09:38 Rev Time 0.30
Received By tgordon Date 2007-01-16 Time 09:38 Sent To  
Notes
2007-01-16 09:41:24MECHANICAL REVISION PAGE M-1
 *** PROVISO ***
 1) PROVIDE COMBUSTION AIR FOR GAS WATER HEATER, PEA
 2001 FBC/M 703.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-01-02 Cont ID  
Sent By tgordon Date 2007-01-02 Time 16:17 Rev Time 0.30
Received By tgordon Date 2007-01-02 Time 16:17 Sent To  
Notes
2007-01-02 16:22:56MECHANICAL REVISION
 *** DENIED ***
 1) CLOTHES WASHERS AND CLOTHES DRYERS MAY NOT BE IN A
 ROOM USED AS A RETURN AIR PLENUM, SEE 2004 FBC
 13-610.1.ABC.3.7.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-02-22 Cont ID  
Sent By tgordon Date 2006-02-22 Time 14:14 Rev Time 0.45
Received By tgordon Date 2006-02-22 Time 14:14 Sent To P
Notes
2006-02-22 00:00:00*** PROVISO ***
 1) GAS WATER HEATER TO BE VENTED BY
 MANUFACTURES'S INSTRUCTIONS AND, OR 2004
 FBC/M CH.8 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-12-16 Cont ID  
Sent By tgordon Date 2005-12-16 Time 08:55 Rev Time 0.30
Received By tgordon Date 2005-12-16 Time 08:55 Sent To P
Notes
2005-12-16 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON
 FORM 600A-04 (2004), PER FBC 13-600.0 .
  
 2) NEED TO PROVIDE COMBUSTION AIR FOR
 GAS WATER HEATER, PER 2004 FBC/M 702.1 .
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-02-28 Cont ID  
Sent By jleech Date 2006-02-28 Time 18:57 Rev Time 0.50
Received By jleech Date 2006-02-28 Time 18:57 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-20 Cont ID  
Sent By jleech Date 2005-12-20 Time 11:15 Rev Time 0.75
Received By jleech Date 2005-12-20 Time 11:15 Sent To B
Notes
2005-12-20 00:00:00DENIED;
 1. PLEASE DELETE GAS RISER DIAGRAM OR
 COMPLY WITH THE FOLLOWING REQUIREMENTS;
 SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2004
 FUEL GAS CODE.
 TYPE OF GAS, (LP OR NATURAL)
 BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2004 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34).
 INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2004 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 2.SANITARY RISER DIAGRAM NOT TO CODE;
 FIRST FLOOR W/C NOT VENTED AS DRAWN.
 LAV. TO DISCHARGE SEPARATE FROM W/M. SEE
 ONE SET OF PLANS MARKED IN RED.
 3.IS WATER HEATER IN ROOM 108? PLEASE
 SHOW ON DRAWING. ALSO SHOW MAKEUP AIR
 FOR W/H PER. SEC. 304 FBC-2004 FUEL GAS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 3 Status N Date 2006-05-19 Cont ID  
Sent By mmclean Date 2006-05-19 Time 16:30 Rev Time 0.00
Received By mmclean Date 2006-05-19 Time 16:30 Sent To I
Notes
2006-05-19 00:00:00NO ZONING REVIEW NEEDED.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-02-21 Cont ID  
Sent By mmclean Date 2006-02-21 Time 14:17 Rev Time 0.00
Received By mmclean Date 2006-02-21 Time 14:17 Sent To I
Notes
2006-02-21 00:00:00NOTE: THE PROPOSED ADDITION SHOWS 10FT
 ON ONE SIDE & 5FT ON THE OTHER, MAKING
 THE TOTAL SIDES 15FT.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-13 Cont ID  
Sent By mmclean Date 2005-12-13 Time 17:28 Rev Time 0.00
Received By mmclean Date 2005-12-13 Time 17:28 Sent To I
Notes
2005-12-13 00:00:00DENIED,
 1. THE PROPOSED ADDITION DOES NOT MEET
 THE SIDES SETBACKS.BOTH SIDE MUST BE
 15FT TOTAL, WITH MINIMUM OF 5FT ON ONE
 SIDE.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720