| Plan Review Stops For Permit 05111159 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-09-19 |
Time |
14:54 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2006-09-19 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2006-09-19 00:00:00 | PERMIT: 05111159 | | | ADD: 1600 OKEECHOBEE RD | | | CONT: THORTON & THORTON INC | | | TEL: (321)229-3406 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 4TH REVIEW/ 3RD FAILURE | | | ACTION: DENIED | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) SHEETS SD-3 & SD-4 81/2X11 HAVE | | | COPIES OF A SIGNATURE NOT THE ORIGINAL | | | SIGNATURE! SEE 481.221. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-05-31 |
Time |
13:33 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-05-31 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-06 |
Time |
09:27 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-04-06 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2006-04-06 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05111159 | | | ADD: 1600 OKEECHOBEE RD | | | CONT: THORTON & THORTON INC | | | TEL: (321)229-3406 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2A) COMPLIED | | | 2B) COMPLIED | | | 2C) COMPLIED | | | 2D) COMPLIED | | | 2E)FROM PREVIOUS REVIEW, IF AN AUTOMATIC | | | SPRINKLER SYSTEM ISPROVIDED, WHETHER | | | THE SPRINKLER SYSTEM IS REQUIRED. IF THE | | | FIRE SPRINKLER IS PROVIDED OR REQUIRED | | | BY CODE THEN THE FIRE SPRINKLER PLANS | | | SHALL BE INCLUDED IN THE BUILDING PERMIT | | | PACKAGE BEFORE ISSUANCE OF THIS PERMIT. | | | NOTE FIRE SPRINKLER PERMIT AND FIRE | | | SPRINKLER PLANS ARE REQUIRED SEPERATELY. | | | 2F) COMPLIED AT THIS TIME. | | | | | | 3)FROM THE PREVIOUS REVIEW, 3) PROVIDE A | | | CURRENT SURVEY OF THE BUILDING,(2004 | | | FBC) 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE & EXTENT OF THE WORK | | | PROPOSED & SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND REVELENT LAWS, ORDINANCES, AND RULES | | | AND REGULATIONS AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | | | | 4)FROM THE PREVIOUS REVIEW, NOT | | | ADDRESSED IN RESPONCE SHEET. | | | IT APPEARS THAT THE SO CALLED MEZANINE | | | NO LONGER MEETS THE DEFINITION SINCE THE | | | AREA BELOW THE MEZANINE CAN'T BE FIGURED | | | INTO THE CLEAR FLOOR AREA. | | | | | | 505.2 AREA LIMITATION. | | | THE AGGREGATE AREA OF A MEZZANINE OR | | | MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. IN DETERMINING THE ALLOWABLE | | | MEZZANINE AREA, THE AREA OF THE | | | MEZZANINE SHALL NOT BE INCLUDED IN THE | | | AREA OF THE ROOM. | | | | | | 5) COMPLIED | | | | | | 6) COMPLIED | | | | | | 7A) FROM THE PREVIOUS REVIEW, | | | 7) PROVIDE EGRESS PATHWAYS FOR THE | | | WAREHOUSE AREAS,116 & 117. THE PLAN | | | SHOWS A EGRESS AISLE IN 116 TO A EXIT | | | AND BACK INTO THE OFFICE OCCUPANCY. NOTE | | | THE OCCUPANTS OF THE OFFICE SHOULD NOT | | | BE TAKEN INTO THE WAREHOUSE STORAGE | | | OCCUPANCY AS PART OF AN EGRESS UNLESS IT | | | IS IN A RATED CORRIDOR! THE EXIT | | | LIGHTINTHE OFFICE AREA THATLEADS INTO | | | THE STORAGE AREA SHOULD BE REMOVED | | | UNLESS A RATED CORRIDOR. | | | 1032.4.1 | | | IN GROUP S1 STORAGE, OCCUPANCIES COMMON | | | PATH OF TRAVEL SHALL NOT EXCEED 50 FEET | | | (15 M). | | | EXCEPTION: COMMON PATHS OF TRAVEL SHALL | | | NOT EXCEED 100 FEET (30 M) IN BUILDINGS | | | PROTECTED BY AN APPROVED AUTOMATIC | | | SPRINKLER SYSTEM. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-08 |
Time |
07:22 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-02-08 |
Time |
07:22 |
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05111159 | | | ADD: 1600 OKEECHOBEE RD | | | CONT: THORTON & THORTON INC | | | TEL: (321)229-3406 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) 110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | | | | 3) PROVIDE ACURRENT SURVEY OF THE | | | BUILDING,(2004 FBC) 106.1.1 | | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE & EXTENT OF THE WORK | | | PROPOSED & SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND REVELENT LAWS, ORDINANCES, AND RULES | | | AND REGULATIONS AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | | | | 4) IT APPEARS THAT THE SO CALLED | | | MEZANINE NO LONGER MEETS THE DEFINITION | | | SINCE THE AREA BELOW THE MEZANINE CAN'T | | | BE FIGURED INTO THE CLEAR FLOOR AREA. | | | | | | 505.2 AREA LIMITATION. | | | THE AGGREGATE AREA OF A MEZZANINE OR | | | MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. IN DETERMINING THE ALLOWABLE | | | MEZZANINE AREA, THE AREA OF THE | | | MEZZANINE SHALL NOT BE INCLUDED IN THE | | | AREA OF THE ROOM. | | | THE PLANS DO NOT INDICATE WHAT TYPE | | | OF OCCUPANCY THE ROOM WILL BE AT THE | | | HEAD OF THE STAIRS, MAY REQUIRE A SECOND | | | MEANS OF EGRESS, ( ENCLOSED STAIR)? | | | | | | 5) PLANS DO NOT PROVIDE WHAT TYPE OF | | | MATERIAL WILL BE STORED IN WAREHOUSE | | | 116 OR 117? THIS MAY REQUIRE EITHER A 1 | | | HR RATED WALL BETWEEN OFFICE AND | | | WAREHOUSE ONCE DECLARE WHAT TYPE OF | | | MATERIALS ARE TO BE STORED?S1 VS S2? | | | | | | 6) PLANS ALSO INDICATE BATTERY CHARGER | | | AND GUARDRAIL? EXPLAIN THE USAGE, AND | | | AMOUNT OF BATTERIES? | | | | | | 7) PROVIDE EGRESS PATHWAYS FOR THE | | | WAREHOUSE AREAS, E1.1 DOES NOT INDICATE | | | EXIT LIGHTS IN WAREHOUSE AREA.1016.1.1 | | | ILLUMINATION OF MEANS OF EGRESS SHALL BE | | | PROVIDED IN ACCORDANCE WITH THIS SECTION | | | FOR EVERY BUILDING AND STRUCTURE.FOR | | | THE PURPOSES OF THIS REQUIREMENT, EXIT | | | ACCESS SHALL INCLUDE ONLY DESIGNATED | | | STAIRS, AISLES, CORRIDORS, RAMPS, | | | ESCALATORS AND PASSAGEWAYS LEADING TO AN | | | EXIT.FOR THE PURPOSES OF THIS | | | REQUIREMENT, EXIT DISCHARGE SHALL | | | INCLUDE ONLY DESIGNATED STAIRS, AISLES, | | | CORRIDORS, RAMPS, ESCALATORS,WALKWAYS | | | AND EXIT PASSAGEWAYS LEADING TO A PUBLIC | | | WAY. | | | | | | 8) SHEET E4.1 MISSING SEAL ON ONE SET OF | | | PLANS.PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-17 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-17 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2006-10-17 18:58:42 | REV FOR LAYOUT OF RECEPTS, AND CORRECTED ELECTRICAL | | | SERVICE EQUIPMENT LAYOUT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-24 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-24 |
Time |
09:15 |
Sent To |
PC |
|
| Notes |
| 2006-09-24 00:00:00 | *** STILL NEED TO REVISE E1.1 TO | | | CORRELATE WITH THE REVISED ELECTRICAL | | | RISER DIAGRAM. | | | THIS RISER OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2006-09-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-10 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-10 |
Time |
12:28 |
Sent To |
|
|
| Notes |
| 2006-09-10 00:00:00 | **** UNSAT *** | | | | | | 1) NOTE: PLEASE SEE REVISED PLANS AS | | | NOTED AND REQUESTED BEFORE ANY ROUGH | | | ELECTRICAL INSPECTIONS HAS NOT BEEN | | | SUBMITTED TO DATE. INSPECTIONS, HAVE | | | BEEN DONE HOWEVER INSPECTION DATED 9/8 | | | FAILED AS NOT READY AND TO SEE NOTES | | | REDLINED ON PLANS HAS NOT BEEN ADDRESS. | | | PLEASE SEE THE ELECTRICAL PERMIT HAS | | | BEEN PLACED ON "HOLD". | | | | | | 2) NOTE: PLEASE SEE THE FOLLOWING IS NOT | | | FOR ELECTRICAL PLANS SUBMITTED. | | | PLEASE SEE 8 1/2X 11'S SUBMITTED AND | | | ATTACHED TO PLANS SUBMITTED CONTAIN | | | RAISED SEALS OVER PHOTO-COPIED SIGNATURE | | | FOR ARCHITECT WHICH IS REQUIRED TO BE AN | | | ORIGINAL SIGNATURE. | | | FS 481.221. | | | PLEASE KNOW, A RAISED SEAL OVER A | | | PHOTO-COPIED SIGNATURE DOES NOT MAKE | | | THIS ORIGINAL AND DOCUMNETS ARE NOT | | | VALID. | | | | | | PLEASE SUBMITE REVISED ELECTRICAL PLANS | | | AS STATED ON "PROVISO/REDLINED NOTES" ON | | | PLANS. | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-03 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-03 |
Time |
16:24 |
Sent To |
PC |
|
| Notes |
| 2006-07-03 00:00:00 | NEED TO REVISE LAYOUT OF PANELS AND | | | IDENTIFICATION ON E 1.1 BEFORE ROUGH. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-21 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-21 |
Time |
11:56 |
Sent To |
PC |
|
| Notes |
| 2006-06-21 00:00:00 | ********* UNSAT *********** | | | | | | 1) NOTE: PLEASE SEE PANELS AS SHOWN ON | | | PLANS E1.1 DO NOT CORRELATE WITH RISER | | | AND PANEL SCHEDULES. | | | PLEASE SEE TWO PANEL "A"'S SHOWN, 1-400A | | | AND 1-200A. PLEASE SEE PANEL "B" WHICH | | | IS SHOWN AS 600A'S ON PLANS AND 200A'S | | | | | | 2) NOTE: PLEASE SEE RISER DIAGRAM | | | INDICATES TWO MDP'S AND ONE OF THE | | | SCHEDULES INDICATES MDB. IS THIS ONE OF | | | THE MDP'S? | | | PLEASE ALSO SEE THE 2ND MDP WHICH IS | | | 400A RATEDSEEMS TO BE FED FROM MDP | | | ONE, WHICH IS 600A'S AND DOES NOT | | | INDICATE ANY OCP FEEDING THE MDP-2?? | | | PLEASE VERIFY IF THIS IS A FEED THUR | | | LUGS , TAPPED CONDUCTOS ETC. | | | PLEASE KNOW, IF TAPPED ? THEN PLEASE SEE | | | 240.21. PLEASE KNOW, AS SHOWN IS SEEMS | | | THE MDP-2 WOULD REQUIRE AND MCB TO LIMIT | | | THE LOAD AND FOR PROTECTION OF WHAT IS | | | NOW SHOWN AS A MLO MDP. | | | PLEASE SEE NO CONDUCTORS ARE BEING | | | INDICATED FOR THE EXISTING MDP ETC. | | | UNABLE TO VERIFY AT THIS TIME. | | | PLEASE SEE 230.70,230.2,230.71,230.72, | | | 240.4,310.16,240.21 ETC. | | | 215.5 | | | | | | 3) NOTE: PLEASE CLARIFY THE DIFFERENCE | | | IN E2.1 AND 2.2. | | | | | | | | | ** PLEASE BE SURE TO REVMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-01 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-01 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2006-06-01 00:00:00 | ************ UNSAT 3RD REVIEW ********* | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES DUE TO PLANS | | | SUBMITTED. | | | | | | | | | 1) NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | PER NEC 2002 220. PLEASE SEE BOTH | | | PREVIOUS REVIEWS REQUESTED THIS. | | | 220.3,220.10,220.11,220.13,215.3,230.42 | | | ETC. | | | ALL NEW LOADS SHALL BE SHOWN BEING ADDED | | | TO EXISITNG LOADS. | | | PLANS ONLY MENTIONS "PROJECTED" NEW | | | LOADS?? | | | | | | 2) NOTE: PLEASE INDICATE AND SHOW ALL | | | ROOM AND AREA DESIGNATIONS ON PLANS. | | | IE: OFFICE, BATHRMS, CLOSETS, STORAGE | | | AREAS, ETC ETC. | | | | | | 3) NOTE: PLEASE SHOW THE LOCATION OF THE | | | PANELS AND SERVICE EQUIPMENT ON PLANS. | | | PLEASE SEE RESPONSE MENTIONS THIS IS NOW | | | SHOWN ON REVISED PLANS, ONLY PANELS "C" | | | AND "D" WERE LOCATED AT WHAT APPEARS TO | | | BE UNDER STAIRS? | | | 215.5 | | | | | | 4) NOTE: PLEASE SEE RISER HAS NOW BEEN | | | REVISED ONCE AGAIN NOW SHOWING A PANEL | | | "D" WHICH WAS NOT ON EITHER OF THE FIRST | | | TWO REVIEWS? | | | PLEASE SEE FIRST SET OF PLANS SHOWED | | | ONLY A PANEL "A" AND "B", THEN A PANEL | | | "C" WAS ADDED AND NOW A 4TH PANEL WAS | | | ADDED. | | | PLANS ALSO INDICATE A MAIN DIST PANEL, | | | YET NO INFORMATION WAS SUBMITTED FOR | | | THIS. | | | PLEASE VERIFY ALL WHICH IS EXISTING AND | | | WHICH IS NEW. | | | PLEASE SEE RISER CONTAINS A VERY SMALL | | | NOTE WHICH MENTIONS ALL IS EXISTING, YET | | | PANELS DO NOT CONTAIN ANY CHECK OR MARK | | | LOCATED IN THE PANEL DISCRIPTION | | | INDICATING NEW OR EXISTING? | | | PLEASE SEE RISER STILL NOT INDICATE SIZE | | | OF SERVICE WHICH LOADS ARE ONOR BEING | | | ADDED TO. | | | 215.5 | | | | | | 5) NOTE: PLEASE COMPLETE CIRCUITING ON | | | PLANS. | | | SEE WAREHOUSE AREA. LTS ARE SHOWN, | | | HOWEVER NO CONTROLS ETC. | | | 215.5 | | | | | | 6) NOTE: PLEASE SEE THE PREVIOUS REVIEWS | | | WITH RESPECT TO THE CIRCUITING OF EM AND | | | EXT LTS. | | | PLEASE SEE THE RESPONSE LTR MENTIONS | | | CIRCUITING MEETS 700.12E , HOWEVER | | | PLEASE SEE ALL EM/EXT LTS SHALL BE | | | CIRCUITED TO THE SAME BRANCH CIRCUIT FOR | | | LIGHTING IN ANY ONE AREA. (IF LTS IN | | | THAT ARE GO OUT, THE EMERGENCY LIGHTING | | | WILL COME ON. | | | PLEASE CORRELATE AND ADJUST ALL | | | CIRCUITING ON PLANS AND PANEL SCHEDULES. | | | | | | 7) NOTE: PLEASE SEE FBC CHAPTER 13 WAS | | | NOTED IN PREVIOUS REVIEW AND RESPONSE | | | MENTIONS THIS WILL BE UNDER SEPARATE | | | PERMIT/WORK? | | | PLEASE KNOW,ALL THIS INFORMATION IS | | | REQUIRED AT THIS TIME FOR REVIEW OF CODE | | | COMPLIANCE. | | | THIS SCOPE OF WORK ON PLAN AS SHOWN | | | REQUIRES THIS INFORMATION AT THIS TIME. | | | PLEASE PROVIDE VOLTAGE DROP WORST CASE | | | PER 13-413.1ABC.1, | | | PLEASE SEE 13-415.1.ABC.1.1, .2, .3. | | | SCHEDULING, OVERIDES, ETC TO BE SHOWN. | | | | | | 8) NOTE: PLEASE CLARIFY THE LOW VOLTGE | | | SHOWN ON PREVIOUS TWO SETS OF PLANS | | | SUBMITTED WERE NOT SUBMITTED WITH NEW | | | PLANS?? IF THE LV IS NOT GOING TO BE | | | INCLUDED, THEN ANY LV WILL BE REQUIRED | | | TO BE UNDER SEPARATE PERMIT, PLANS AND | | | FEES. | | | THIS IS ONLY NOTED. | | | | | | 9) NOTE: PLEASE SEE PREVIOUS NOTES GAVE | | | A NOTICE TO FLORIDA STATUES 553.80(2)(B) | | | WITH RESPECT TO THE DESIGN PROFESSIONALS | | | AND REPEAT COMMENTS FOR CODE COMPLIANCE. | | | PLEASE KNOW, DUE TO ONE OR MORE OF THE | | | COMMENTS BEING THE SAME FOR THE THIRD | | | REVIEW, A 4X PLAN REVIEW FEE WAS ADDED | | | AS REQUIRED BY THE FS. | | | PLEASE KNOW, A FEEOF $3600.00 WAS ADDED | | | FOR THE PLAN REVIEW PORTION. | | | THIS FEE IS BASED ON 30% OF THE BASE | | | PERMIT FEE TIMES FOUR. THIS FEE IS | | | REQUIRED TO BE PAID BEFORE SUBMITTING | | | PLANS FOR FOURTH REVIEW. | | | ** PLEASE KNOW, ONE COPY OF ALL THREE | | | SETS OF PLANS ARE NOW BEING RETAINED BY | | | THIS OFFICE FOR POSSIBLE REVIEW BY THE | | | STATE OF FLORIDA BOARD OF ARCHITECTS AND | | | LEGAL COUNSEL TO THE BOARD. | | | ** PLEASE KNOW, IT IS RECOMMENDED A | | | MEETING BE SET UP TO GO OVER PLANS AND | | | COMMENTS TO HELP ALLEAVIATE ANY SUCH | | | ADDITIONAL FEESAND ANY FURTHER DELAYS | | | IN THE PROJECT START DATE. | | | PLEASE SEE COPY THE THE FS IS ATTACHED | | | ONCE AGAIN. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW AND PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE TO GO OVER | | | COMMENTS OR QUESTIONS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-23 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-22 |
Time |
20:16 |
Sent To |
|
|
| Notes |
| 2006-03-23 00:00:00 | *** UNSAT 2ND REVIEW *** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND NEW NOTES FOR INFORMATION | | | ADDED TO PLANS. | | | FIRST SET OF NOTES BELOW ARE TAKEN | | | DIRECTLY FROM FIRST REVIEW. | | | | | | ************* UNSAT ************** | | | | | | 1)NOTE: OK | | | | | | 2)NOTE:OK/ NO, HSEE NEW NOTES FOR | | | CIRCUIT. PLEASE ALSO SEE ROOM AND AREA | | | DESIGNATIONS WERENOT REVISED. | | | | | | 3)NOTE: NO, PLEASE SHOW ALL PANEL | | | LOCATIONS. NEED TO VERIFY 11.26,240.24, | | | 407.7 ETC | | | | | | **PRE REVIEW ** | | | PLEASE SEE LEGEND NOTES SHOWS | | | METER AND PANELS, HOWEVER THESE COULD | | | NOT BE LCOATE DON PLANS. PLEASE SHOW | | | PANEL LOCATIONS. PLEASE BE SURE TO SEE | | | 110.26, 240.24. | | | 215.5 | | | | | | 4)NOTE: NO, PLEASE SEE THE LOADS WHICH | | | WERE SUBMITTED SEEM ONLY TO BE FOR NEW | | | LOADS ADDED AND LENDS NO INFORMATION FOR | | | EXISTING LOADS THIS LOAD IS ADDED TO AND | | | THE SIZE OF EXISTING SERVICE AS BEING | | | NOTED. | | | NEED TO VERIFY CAPACITY ETC. | | | PLEASE ALSO VERIFY ALL CONTINOUS LOADS( | | | LIGHTING) AT 125%. | | | | | | ** PRE-REVIEW** | | | PLEASE SUBMIT LOAD CALCULATIONS | | | FOR SAID PANELS. | | | ARE THEY FED FROM OTHER PANELS? OR IS | | | THE TWO PANELS SUBMITTED THE ONLY PANELS | | | FROM SERVICE? | | | PLEASE SEE THE ONLY ITEMS SHOWN ON PANEL | | | SCHEDULES ARE LTS AND RECEPTS? | | | ARE OTHER LOADS, A/C ETC ON OTHER | | | PANELS? | | | PLEASE BE SURE TO SEE 220.10, 220.3, | | | 220.11, 220.13, ETC | | | PLEASE ALSO SHOW ALL CONTINUOUS LOADS | | | @125%. LIGHTING/LARGEST MOTOR. ETC | | | | | | 6)NOTE:OK. | | | | | | 7)NOTE:NO, COULD NOT LOCATE AS | | | RESPONSE LTR MENTIONS THESE ARE ADDED. | | | | | | ** PRE REVIEW ** | | | PLEASE SEE NO RECEPTS ARE SHOWN | | | IN BATH RM(S) OR KITCHEN/LUNCH ROOM? | | | PLEASE VERIFY. | | | PLEASE SEE 2002 NEC 210.8B, 210.8B3 | | | WHICH REQUIRES ALL 15- AND 20-AMPERE, | | | 125-VOLT RECEPTACLES IN NONDWELLING-TYPE | | | KITCHENS TO BE GFCI PROTECTED. THIS | | | REQUIREMENT APPLIES TO EACH AND EVERY | | | 15- AND 20-AMPERE, 125-VOLT KITCHEN | | | RECEPTACLE, WHETHER OR NOT THE | | | RECEPTACLE SERVES COUNTERTOP APPLIANCES. | | | | | | 8)NOTE:NO, PLEASE SEE RESPONSE LTR | | | MENTIONS THE TITLE BLOCKS WERE REVISED, | | | HOWEVER THE "PRINTED NAME AND PRINTED | | | LICENSE NUMBER " OF ARCHITECT COULD NOT | | | BE LOCATED ON SAID TITLE BLOCKS AS | | | REQUIRED. | | | | | | ** PRE- REVIEW ** | | | PLEASE SEE FAC 61G1-16.004 WHICH | | | ALSO REQUIRES THE PRINTED NAME AND | | | LICENSE # OF SAID ARCHITECT. | | | PLEASE KNOW THIS IS REQUIRED OF ALL | | | TRADES AND FOR ALL SHEETS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 9)NOTE: OK. | | | | | | 10)NOTE:NO, PLEASE SEE THIS PROJECT IS | | | ON "OKEECHOBEE RD AND PLANS NEED TO | | | REFLECT THIS.OLD OKEECHOBEE IS NOT | | | ACCURATE. IT IS KNOWN TO THIS OFFICE | | | THAT PBCPA OFFICE INDICATES THIS AS "OLD | | | " AND THE STREET SIGNS EVEN INDICATE | | | THIS. | | | PLEASE SEE BLDG REVIEW. | | | | | | ** PRE- NOTES** | | | PLEASE SEE PERMIT APPLICATION | | | AND PLANS BOTH MENTIONS "OLD" | | | OKEECHOBEE. | | | PLEASE KNOW AND PLEASE SEE PALM BEACH | | | COUNTY PROPERY APPRAISER'S RECORDS AND | | | CITY OF WEST PALM BEACH RECORDS FOR THIS | | | PCN NUMBER IS FOR "OKEECHOBEE RD". | | | PLEASE ADJUST PLANS ETC. | | | | | | NEW NOTES** | | | | | | 1) NOTE: PLEASE SEE CIRCUITING IS NOW | | | SHOWN, HOWEVER PLEASE SEE 700.12E WHICH | | | REQUIRES ALL EM/EXT LTS TO BE CIRCUITED | | | TO THE LOCAL BRANCH CIRCUIT IN THE AREA | | | IN WHICH THESE ARE LOCATED. | | | | | | 2)NOTE: PLEASE SEE FBC 2004, CHAPTER 13, | | | | | | PLEASE PROVIDE WORST CASE VDPER | | | 13-413.1ABC.1 | | | PLEASE PROVIDE ALL AUTOMATED SYSTEM(S) | | | INFORMATION AS REQUIRED PER | | | 13-415.1.ABC.1 AND .2 | | | PLEASE SUBMIT SCHEDULING, OVERRIDES, | | | OCCUPANCY SENSOR INFORMATION AND TYOE OF | | | SYSTEM TO BE INSTALLED. | | | CIRCUITING WAS NOT SHOWN ON PREVIOUS | | | PLANS. | | | | | | 3) NOTE: PLEASE SEE FS 553.80(2)(B) WITH | | | RESPECT TO DESIGN PROFESSIONAL AND | | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | | THIS IS ONLY A NOTICE. | | | | | | | | | ** PLEASE SEE ANY OTHER POSSIBLE | | | COMMENTS FROM OTHER REVIEWER(S) WHICH | | | MAY AFFECT ELECTRICAL PLANS. | | | | | | | | | *************************************** | | | ** PLEASE DO NOT ATTACHED THE OLD SETS | | | TO THE NEW SETS. ONLY ONE OLD SET SHOULD | | | BE SUBMITTED AND THIS SET SHOULD BE | | | SEPARATE. | | | ************************************* | | | | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE SET OF ANY OLD/VOIDED | | | REMOVED SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | 2006-03-22 00:00:00 | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-24 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-24 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2005-12-24 00:00:00 | ************* UNSAT ************** | | | | | | 1)NOTE: PLEASE SEE FIRE REVIEW NOTES, | | | PLEASE SEE AS OF JAN 1ST, 2005 WE ARE | | | CURRENTLY UNDER THE 2003 LS-101 | | | | | | 2)NOTE: PLEASE SHOW ALL CIRCUTING ON | | | PLANS AND CORRELATE WITH THE PANEL | | | SCHEDULES SUBMITTED. | | | PLEASE KNOW, EACH CIRCUIT SHALL BE | | | IDENTIFIED FOR EACH PANEL. A,B ETC. | | | ROOM AND AREA DESIGANTIONS SHALL ALSO BE | | | PLACED ON PLANS, WHICH WILL CORRELATE | | | WITH THE CIRCUITING ON PANEL SCHEDULE. | | | PANEL SCHEDULE SHOULD NOTE BATHRM | | | CIRCUIT# X. ETC. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE LEGEND NOTES SHOWS | | | METER AND PANELS, HOWEVER THESE COULD | | | NOT BE LCOATE DON PLANS. PLEASE SHOW | | | PANEL LOCATIONS. PLEASE BE SURE TO SEE | | | 110.26, 240.24. | | | 215.5 | | | | | | 4)NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | | FOR SAID PANELS. | | | ARE THEY FED FROM OTHER PANELS? OR IS | | | THE TWO PANELS SUBMITTED THE ONLY PANELS | | | FROM SERVICE? | | | PLEASE SEE THE ONLY ITEMS SHOWN ON PANEL | | | SCHEDULES ARE LTS AND RECEPTS? | | | ARE OTHER LOADS, A/C ETC ON OTHER | | | PANELS? | | | PLEASE BE SURE TO SEE 220.10, 220.3, | | | 220.11, 220.13, ETC | | | PLEASE ALSO SHOW ALL CONTINUOUS LOADS | | | @125%. LIGHTING/LARGEST MOTOR. ETC | | | | | | 6)NOTE: PLEASE INDICATE NEW OR EXSITING | | | SIGN CIRCUIT REQUIRED PER 600.5 AT FRONT | | | DOOR LOCATION. | | | | | | 7)NOTE: PLEASE SEE NO RECEPTS ARE SHOWN | | | IN BATH RM(S) OR KITCHEN/LUNCH ROOM? | | | PLEASE VERIFY. | | | PLEASE SEE 2002 NEC 210.8B, 210.8B3 | | | WHICH REQUIRES ALL 15- AND 20-AMPERE, | | | 125-VOLT RECEPTACLES IN NONDWELLING-TYPE | | | KITCHENS TO BE GFCI PROTECTED. THIS | | | REQUIREMENT APPLIES TO EACH AND EVERY | | | 15- AND 20-AMPERE, 125-VOLT KITCHEN | | | RECEPTACLE, WHETHER OR NOT THE | | | RECEPTACLE SERVES COUNTERTOP APPLIANCES. | | | | | | 8)NOTE: PLEASE SEE FAC 61G1-16.004 WHICH | | | ALSO REQUIRES THE PRINTED NAME AND | | | LICENSE # OF SAID ARCHITECT. | | | PLEASE KNOW THIS IS REQUIRED OF ALL | | | TRADES AND FOR ALL SHEETS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 9)NOTE: PLEASE SEE SHEET 4 OF 5 IN ONE | | | SETIS NOT SEALED BY SAID ARCHITECT. | | | FS 481.221 | | | | | | 10)NOTE: PLEASE SEE PERMIT APPLICATION | | | AND PLANS BOTH MENTIONS "OLD" | | | OKEECHOBEE. | | | PLEASE KNOW AND PLEASE SEE PALM BEACH | | | COUNTY PROPERY APPRAISER'S RECORDS AND | | | CITY OF WEST PALM BEACH RECORDS FOR THIS | | | PCN NUMBER IS FOR "OKEECHOBEE RD". | | | PLEASE ADJUST PLANS ETC. | | | | | | | | | ** PLEASE SEE ANY OTHER POSSIBLE | | | COMMENTS FROM OTHER REVIEWER(S) WHICH | | | MAY AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE SET OF ANY OLD/VOIDED | | | REMOVED SHEETS FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-06-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-06 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-06 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-04-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-04-06 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-04-06 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2006-04-06 00:00:00 | ******DENIED****** | | | | | | 1) EXITS AND EMERGENCY LIGHTING ARE | | | ILLUSTRATED DIFFERENTLY ON EACH SHEET. | | | PLEASE CORRULATE, AND CLEARLY IDENTIFY | | | LOCATIONS. ARE THERE ENOUGH EXITS IN | | | WAREHOUSE AREAS? SHT A-5 WAS INDICATED | | | FOR REFERENCE, HOWEVER THAT SHEET HAS | | | BEEN VOIDED. SHT E-1.1 DOES NOT SHOW ANY | | | EMERGENCY LIGHTING IN AREA 116. | | | | | | 2) DETAILS FOR STORAGE RACKS ARE | | | REQUIRED FOR REVIEW PRIOR TO APPROVAL OF | | | DRAWINGS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-12-21 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-12-21 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2005-12-21 00:00:00 | 1. WRONG LIFE SAFETY CODE REFERENCED. | | | SHOULD READ 2003 EDITION NOT 2001 | | | EDITION. | | | | | | 2. ALL DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 3. DEBRIS SHALL BE REMOVED FROM THE SITE | | | DAILY. | | | | | | 4. ALL EXITS ARE TO REMIAN CLEAR AND | | | UNOBSTRUCTED. | | | | | | 5. GASOLINE POWERED EQUIPMENT SHOULD NOT | | | BE USED INDOORS DUE TO THE RISK OF | | | CARBON MONIXIDE BUILD-UP. | | | | | | 6. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR ANY FIRE SPRINKLER SYSTEM | | | MODIFICATION. | | | | | | 7. PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATIONS FOR WALLS AND CEILINGS. | | | | | | 8. SECURITY PLAN APPEARS TO BE ABSENT OF | | | DEVICES THAT ARE REFLECTED IN THE KEY ON | | | PAGE E3.1. | | | | | | 9. PLEASE ILLUSTRATE EXIT SIGNS AND | | | EMERGENCY LIGHTING IN WAREHOUSE AREA | | | 116, AND 117. | | | | | | 10. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR ANY FIRE ALARM SYSTEM REMODELING. | | | | | | 11. PLEASE PROVIDE MORE DETAILS ON | | | BATTERY CHARGER EQUIPMENT CONTAINED IN | | | WAREHOUSE 116. | | | | | | 12. PLEASE PROVIDE DETAILS ON STORAGE | | | RACKS ILLUSTRATED WITHIN THE PLANS. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-03 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-03 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2006-10-17 13:31:58 | TO "COMM" BD#9 | | 2006-10-03 00:00:00 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-09-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-19 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-19 |
Time |
14:04 |
Sent To |
E |
|
| Notes |
| 2006-09-19 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-25 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-25 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2006-08-25 00:00:00 | WAITING FOR "COMM" BD-REV | | | TO "COMM" BD#34 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-03 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-03 |
Time |
15:55 |
Sent To |
E |
|
| Notes |
| 2006-07-03 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-20 |
Time |
15:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-20 |
Time |
15:02 |
Sent To |
E |
|
| Notes |
| 2006-06-20 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-15 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-15 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2006-05-31 00:00:00 | TO "COMM" BD#9 | | 2006-05-15 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-28 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-28 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2006-03-21 00:00:00 | TO COMM BOARD #34 | | 2006-02-28 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-18 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-02-18 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-12-02 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2006-02-18 00:00:00 | ENTERED "N" PES | | 2005-12-20 00:00:00 | TO "COMM" BD#31 | | 2005-12-02 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2006-06-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-01 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-01 |
Time |
07:17 |
Sent To |
|
|
| Notes |
| 2006-06-01 00:00:00 | NO MECHANICAL PLANS OR CONTRACTOR | | | INDICATED WITH PERMIT APPLICATION. | | | PLEASE PROVIDE PLANS WITH MECHANICAL | | | PERMIT APPLICATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-04-12 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-04-12 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2006-04-12 00:00:00 | NO MECHANICAL PLANS 4/12/06 HM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-23 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-23 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2006-01-23 00:00:00 | MECHANICAL PLANS OR CONTRACTOR WERE | | | SUBMITTED WITH THE BUILDING PERMIT | | | APPLICATION.PLEASE PROVIDE PLANS WITH | | | MECHANICAL PERMIT APPLICATION.PLEASE | | | INDICATE EXISTING, NEW OR RELOCATED | | | WORK.PLEASE NOTE, FIRE DAMPERS ARE | | | REQUIRED WHEN PENETRATING RATED | | | PARTITIONS OR WALLS.PLEASE INDICATE | | | LOCATION OF NEW OR EXISTING FIRE | | | DAMPERS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-12 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-12 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2006-09-12 00:00:00 | DENIED | | | REFERENCE: FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. PLUMBING REVISION DENIED. THE PLANS | | | SHALL HAVE AN ORIGINAL SIGNATURE. THE | | | SIGNATURES ARE PHOTO COPIES. THE TITLE | | | BLOCK SHALL HAVE A SPACE FOR THE PRINTED | | | NAME OPF THE PERSON SEALING THE | | | DOCUMENT. FAC 61G1-16.004(5)(6) AND FS | | | 481.2055. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-06-02 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-06-02 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-06-02 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | SEE PROVISO: SHT'S P-1,P-2 | | | F/S FOR I/D WASTE. | | | NO WATER COOLER D/F REQUIRED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-04-19 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-04-19 |
Time |
09:28 |
Sent To |
M |
|
| Notes |
| 2006-04-19 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | UNSAT | | | 1)SHT CS, PREVIOUS NOTES NOT ADDRESSED. | | | URINAL,EYE WASH AND BREAK ROOM SINKS NOT | | | SHOWN ON BUILDING DATA FIXTURE COUNT. | | | | | | 2)SHT A-2 SHOW LOCATION OF DRINKING | | | FOUNTAIN. | | | 3) SHT A-4 DETAILS CORELATE DETAILS FOR | | | THE LUNCH ROOM SINK AND COFFEE COUNTER | | | SINK. | | | 4) SHT A-2 11-4.24 SINKS.NO DOORS ON | | | CABINETS, SHOW CLEAR FLOOR SPACE. | | | 11-4.24.1 GENERAL. | | | SINKS REQUIRED TO BE ACCESSIBLE BY | | | SECTION 11-4.1 SHALL COMPLY WITH SECTION | | | 11-4.24. | | | 11-4.24.4 DEPTH. | | | EACH SINK SHALL BE A MAXIMUM OF 6? | | | INCHES (165 MM) DEEP. | | | 11-4.24.5 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE AT LEAST 30 INCHES | | | BY 48 INCHES (760 MM BY 1219 MM) | | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE | | | PROVIDED IN FRONT OF A SINK TO ALLOW | | | FORWARD APPROACH. THE CLEAR FLOOR SPACE | | | SHALL BE ON AN ACCESSIBLE ROUTE AND | | | SHALL EXTEND A MAXIMUM OF 19 INCHES (485 | | | MM) UNDERNEATH THE SINK (SEE FIGURE | | | 11-32). | | | 11-4.24.7 FAUCETS. | | | FAUCETS SHALL COMPLY WITH SECTION | | | 11-4.27.4. LEVER-OPERATED, PUSH-TYPE, | | | TOUCH-TYPE, OR ELECTRONICALLY CONTROLLED | | | MECHANISMS ARE ACCEPTABLE DESIGNS. | | | 5) SHT A-2 VENDING MACHINE.PROVIDE | | | INFORMATION ON INDIRECT WASTE FOR | | | VENDING MACHINES. | | | 6) SHT P-1 CORELATE PLUMBING FIXTURE | | | SCHEDULE WITH FIXTURE LAYOUT. | | | 7) SHT P-1,2SHOW ACCESIBLELOCATION | | | OF WATER HEATER. | | | 607.3 THERMAL EXPANSION CONTROL. | | | A MEANS OF CONTROLLING INCREASED | | | PRESSURE CAUSED BY THERMAL EXPANSION | | | SHALL BE PROVIDED WHERE REQUIRED IN | | | ACCORDANCE WITH SECTIONS 607.3.1 AND | | | 607.3.2. | | | 607.3.1 PRESSURE-REDUCING VALVE. | | | FOR WATER SERVICE SYSTEM SIZES UP TO AND | | | INCLUDING 2 INCHES (51 MM), A DEVICE FOR | | | CONTROLLING PRESSURE SHALL BE INSTALLED | | | WHERE, BECAUSE OF THERMAL EXPANSION, THE | | | PRESSURE ON THE DOWNSTREAM SIDE OF A | | | PRESSURE-REDUCING VALVE EXCEEDS THE | | | PRESSURE-REDUCING VALVE SETTING. | | | 607.3.2 BACKFLOW PREVENTION DEVICE OR | | | CHECK VALVE. | | | WHERE A BACKFLOW PREVENTION DEVICE, | | | CHECK VALVE OR OTHER DEVICE IS INSTALLED | | | ON A WATER SUPPLY SYSTEM UTILIZING | | | STORAGE WATER HEATING EQUIPMENT SUCH | | | THAT THERMAL EXPANSION CAUSES AN | | | INCREASE IN PRESSURE, A DEVICE FOR | | | CONTROLLING PRESSURE SHALL BE INSTALLED. | | | 8)SHT P-2 WATER RISER | | | SECTION 606 INSTALLATION OF THE BUILDING | | | WATER DISTRIBUTION SYSTEM | | | 606.1 LOCATION OF FULL-OPEN VALVES. | | | FULL-OPEN VALVES SHALL BE INSTALLED IN | | | THE FOLLOWING LOCATIONS: | | | 1. ON THE BUILDING WATER SERVICE PIPE | | | FROM THE PUBLIC WATER SUPPLY NEAR THE | | | CURB. | | | 2. ON THE WATER DISTRIBUTION SUPPLY PIPE | | | AT THE ENTRANCE INTO THE STRUCTURE. | | | 3. ON THE BASE OF EVERY WATER RISER PIPE | | | IN OCCUPANCIES OTHER THAN | | | MULTIPLE-FAMILY RESIDENTIAL OCCUPANCIES | | | THAT ARE TWO STORIES OR LESS IN HEIGHT | | | AND IN ONE- AND TWO-FAMILY RESIDENTIAL | | | OCCUPANCIES. | | | 4. ON THE TOP OF EVERY WATER DOWN-FEED | | | PIPE IN OCCUPANCIES OTHER THAN ONE- AND | | | TWO-FAMILY RESIDENTIAL OCCUPANCIES. | | | 9) SHT P-2 WATER HAMMER ARRESTORS SHOWN | | | AT TOP OF RISER IS NOT PER THE | | | MANFACTURE INSTALLATION INSTRUCTIONS. | | | SHOULD BE AT POINT OF SERVICE, OR | | | BETWEEN THE LAST TWO FIXTURES. | | | 10) SHT P-2 WATER AND SANITARY RISRER IS | | | NOT SHOWING ALL OFF THE FIXTURES.I COUNT | | | AT LEAST 14 FIXTURES. | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-18 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-02-18 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-02-18 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2006-02-18 00:00:00 | PLUMBING PLAN REVIEW EXAMINER | | | PAUL SCHMITZ 561-805-6692 | | | [email protected] | | | FBC PLUMBING 2004 | | | FBC FUEL GAS 2004 | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | CH 1, ADMINISTRATION, 2004 EDITION | | | ( ATFBC) | | | FBC BUILDING 2004, CH 11 | | | DENIED | | | | | | 1)SHT CS BUILDING DATA | | | MINIMUM FACILITIES TABLE 403.1 | | | MIXED USE, NUMBER OF W/C ON PLANS, FOUR. | | | FOURREQUIRED. | | | REST RM 113, URNIAL IS NOT SHOWN IN | | | FIXTURE COUNT. | | | LAVATORIES: THREE SHOWN, THREE REQUIRED. | | | DRINKING FOUNTAIN: ONE REQUIRED. | | | EYE WASH SHOWER: ONE REQUIRED SEC 411. | | | SERVICE SINK: NOT SHOWN ON FIXTURE COUNT | | | ONE SHOWN IN ROOM 109. | | | MERCHANTILE: MEN, WOMEN.1-W/C, 1-LAV. | | | 1-D/F, 1-S/S. | | | STORAGE: MEN, WOMEN, 1-W/C, 1-LAV, | | | 1- EYE WASH SHOWER, SEC 411 | | | BUSINESS: MEN,WOMEN 1-W/C,1-LAV.1-D/F. | | | | | | 2) SHT CS SHEET INDEX SHOWS P-1,P-2 NOT | | | INCLUDED IN SUBMITTED SET OF PLANS. | | | | | | 3) (ATFBC) SEC 106.3.5.1.3 (3)(4) | | | COMMERICAL BUILDINGS, PLUMBING SANITARY | | | DRAINAGE, WATER PIPING ISOMETRIC REQ. | | | 3) SHT A-4 DETAIL B-A-4 DINENSION ON W/C | | | OFF WALL IS 18 INCHES. | | | | | | 4) SECTION 11-4 | | | ACCESSIBLE ELEMENTS AND SPACES: | | | SCOPE AND TECHNICAL REQUIREMENTS | | | 11-4.1 MINIMUM REQUIREMENTS. | | | 11-4.1.1 APPLICATION. | | | (1) GENERAL. THIS CODE ESTABLISHES THE | | | MINIMUM STANDARDS FOR THE ACCESSIBILITY | | | OF BUILDINGS AND FACILITIES BUILT OR | | | ALTERED WITHIN THE STATE. | | | (A) ALL AREAS OF NEWLY DESIGNED OR NEWLY | | | CONSTRUCTED BUILDINGS AND FACILITIES | | | REQUIRED TO BE ACCESSIBLE BY SECTION | | | 11-4.1.2 AND SECTION 11-4.1.3 AND | | | ALTERED PORTIONS OF EXISTING BUILDINGS | | | AND FACILITIES REQUIRED TO BE ACCESSIBLE | | | BY SECTION 11-4.1.6 SHALL COMPLY WITH | | | THIS CODE, SECTION 11-4.1 THROUGH | | | SECTION 11-4.35, UNLESS OTHERWISE | | | PROVIDED IN THIS SECTION OR AS MODIFIED | | | IN A SPECIAL APPLICATION SECTION. | | | SHOW ELEVATIONS, DIMIENSIONS, TURNING | | | SPACE FOR REQUIRED PLUMBING FIXTURES. | | | | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | | | | |
|
|