Plan Review Details - Permit 05111074
Plan Review Stops For Permit 05111074
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-03-23 Cont ID  
Sent By amorse Date 2006-03-23 Time 11:07 Rev Time 0.50
Received By amorse Date 2006-03-23 Time 11:07 Sent To PC
Notes
2006-03-23 00:00:00 
  
 ****PROVISO****
 RETAINING WALL SHALL BE FULLY GROUTED
 PER 1806.4 FBC
  
  
 ****PROVISO****
 STAIR TREADS AND RISERS SHALL COMPLY
 WITH R311.5.3 FBC
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-20 Cont ID  
Sent By amorse Date 2005-12-20 Time 16:13 Rev Time 0.50
Received By amorse Date 2005-12-20 Time 16:13 Sent To PC
Notes
2005-12-20 00:00:00 
  
 DENIED
  
  
 1) RETAINING WALLS SHALL COMPLY WITH
 1806 OF THE 2004 FL BLDG CODE EFFECTIVE
 OCT.1, 2005
  
 2) STATE ALL PERTINENT INFORMATION ON
 DRAWINGS SUCH AS WALL HEIGHT, ELEVATION
 DIFFERENCE BETWEEN SIDEWALK AND EARTH TO
 BE RETAINED, ETC.
  
 3) MASONARY SHALL BE FULLY GROUTED WITH
 A MINIMUM OF 1500 PSI. SHOW ON DRAWINGS
  
 4) RETAINING WALLS SHALL BE DESIGNED TO
 RESIST THE SOIL LOADS IN SECTION 1610 OF
 THE 2004 FL BLDG CODE AND SHALL INCLUDE
 THE HYDROSTATIC PRESSURE UNLESS DRAINAGE
 IS PERMITTED AND PROVIDED
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-22 Cont ID  
Sent By dpalmer Date 2006-03-22 Time 12:49 Rev Time 0.00
Received By dpalmer Date 2006-03-22 Time 12:49 Sent To B
Notes
2006-03-22 00:00:00TO AM'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-10 Cont ID  
Sent By adarroug Date 2005-12-10 Time 09:44 Rev Time 0.00
Received By adarroug Date 2005-12-10 Time 09:44 Sent To B
Notes
2005-12-10 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2005-12-20 Time   Rev Time 0.00
Received By adarroug Date 2005-11-30 Time 09:50 Sent To  
Notes
2005-11-30 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2005-12-09 Cont ID  
Sent By mmclean Date 2005-12-09 Time 17:57 Rev Time 0.00
Received By mmclean Date 2005-12-09 Time 17:57 Sent To I
Notes
2005-12-09 00:00:00MAXIMUM HEIGHT ALLOWED WITHIN THE FRONT
 SETBACK IS 4FT.