Plan Review Details - Permit 05111024
Plan Review Stops For Permit 05111024
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2005-11-28 Cont ID  
Sent By ptjomsto Date 2005-11-28 Time 12:17 Rev Time 0.00
Received By jleahy Date 2005-11-28 Time 19:08 Sent To  
Notes
2005-11-28 00:00:00PCN # NEEDS TO BE VERIFIED/COMMUNITY
 PLUS READS 74434315180000050 WITH
 DIFFERENT OWNER AND PB CTY & OWNER
 RECORDS READS 74434315420101001

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-12-22 Cont ID  
Sent By jwitmer Date 2005-12-22 Time 14:04 Rev Time 0.77
Received By jwitmer Date 2005-12-22 Time 14:04 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-01 Cont ID  
Sent By jwitmer Date 2005-12-01 Time 09:01 Rev Time 0.77
Received By jwitmer Date 2005-12-01 Time 08:57 Sent To PC
Notes
2005-12-01 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05111024
 ADD: 1551 N FLAGLER # 1001
 CONT: RICHARD BROWN
 TEL: (561)533-1320
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) MISSING OR INCORRECT INFORMATION
 REQUIRED FOR CERTIFICATE OF OCC. AND FOR
 RECORD KEEPING PURPOSES.
 1A) THE EDITION OF THE CODE UNDER WHICH
 THE PERMIT WAS ISSUED. (2004)
 1B)THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6 . SEE TABLE 601
 1C) THE DESIGN OCCUPANT LOAD.
 1D)IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 1E) ANY SPECIAL STIPULATIONS AND
 CONDITIONS OF THE BUILDING PERMIT.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-12-16 Cont ID  
Sent By jleahy Date 2005-12-16 Time 19:06 Rev Time 0.45
Received By jleahy Date 2005-12-16 Time 19:05 Sent To  
Notes
2005-12-16 00:00:00NEED PANEL SCHEDULE FOR NEW CIRCUITS AND
 LAYOUT SHOW ARC FAULT CIRCUITS ON PANEL
 SCHEDULE
  
 JAKE LEAHY644-7291

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-11-30 Cont ID  
Sent By jleahy Date 2005-11-30 Time 15:53 Rev Time 0.45
Received By jleahy Date 2005-11-30 Time 15:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-12-20 Cont ID  
Sent By nmccray Date 2005-12-20 Time 11:45 Rev Time 0.00
Received By nmccray Date 2005-12-20 Time 11:37 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2005-11-30 Cont ID  
Sent By nmccray Date 2005-11-30 Time 11:57 Rev Time 0.00
Received By nmccray Date 2005-11-30 Time 11:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-15 Cont ID  
Sent By adarroug Date 2005-12-15 Time 09:31 Rev Time 0.00
Received By adarroug Date 2005-12-15 Time 09:31 Sent To  
Notes
2005-12-15 00:00:00TO "BOB"#6

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-01 Cont ID  
Sent By jwitmer Date 2005-12-01 Time 08:57 Rev Time 0.00
Received By jwitmer Date 2005-11-29 Time 13:53 Sent To  
Notes
2005-11-29 00:00:00TO "BOB"#1

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-12-19 Cont ID  
Sent By tgordon Date 2005-12-19 Time 16:16 Rev Time 0.30
Received By tgordon Date 2005-12-19 Time 16:16 Sent To  
Notes
2005-12-19 00:00:00*** PROVISO ***
 1) CLOTHES DRYER EXHAUST MAY NOT EXCEED
 25 FEET, AND THE LENGTH REDUCED 2 1/2FT.
 TO 5 FEET PER BEND, PER 2004
 FBC/M504.6.1 .
  
 2) MASTER BATH WITH SHOWER REQUIRES A
 EXHAUST FAN, PER 2004 FBC/M 402.3.1 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-11-30 Cont ID  
Sent By rregueir Date 2005-11-30 Time 16:49 Rev Time 0.00
Received By rregueir Date 2005-11-30 Time 16:44 Sent To  
Notes
2005-11-30 00:00:00------------------DENIED----------------
  
 1)NO DRAWINGS IN FORMATION REGARDING
 SCOPE OF WORK SUBMITTED WITH
 APPLICATION.PLEASE SUBMIT MECHANICAL
 DRAWINGS FOR REVIEW.
  
 2)PLAN GENERAL NOTES REFERENCE 2001
 FLORIDA BUILDING CODE. ALL PERMIT
 APPLICATIONS SUBMITTED AFTER 9/30/2005
 FALL UNDER FBC 2004.
  
 RONALD J REGUEIRO
 561.805.6734
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-12-16 Cont ID  
Sent By jleech Date 2005-12-16 Time 08:41 Rev Time 0.50
Received By jleech Date 2005-12-16 Time 08:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-11-30 Cont ID  
Sent By jleech Date 2005-11-30 Time 13:26 Rev Time 1.00
Received By jleech Date 2005-11-30 Time 13:26 Sent To  
Notes
2005-11-30 00:00:00DENIED;
 NOT ENOUGH INFORMATION PLEASE SUBMIT OLD
 OLD FLOOR PLAN FOR REVIEW. MARK ON FLOOR
 PLAN FIXTURES TO REMAIN AND FIXTURE
 MOVED
 AUTO-VENTS CAN ONLY BE USED ON TOP 4
 FLOORS MANUFACTURE'S RECOMENDATIONS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695