Plan Review Details - Permit 05111015
| Plan Review Stops For Permit 05111015 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-01 |
Time |
14:46 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2005-12-01 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2005-12-01 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05111015 | | | ADD: 917 N FLAGLER DR# 403 | | | CONT: PROJECT ONE INTERIORS INC | | | TEL: (561)833-9441 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)MISSING INFORMATION REQUIRED ON PLANS: | | | 110.2* | | | 2A) THE EDITION OF THE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | 2B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3 . | | | 2C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6 . | | | 2D) THE DESIGN OCCUPANT LOAD. | | | 2E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | 2F) ANY SPECIAL STIPULATIONS AND | | | CONDITIONS OF THE BUILDING PERMIT. | | | | | | 3) 803.5 INTERIOR FINISH REQUIREMENTS | | | BASED ON GROUP. | | | INTERIOR WALL AND CEILING FINISH SHALL | | | HAVE A FLAME SPREAD INDEX NOT GREATER | | | THAN THAT SPECIFIED IN TABLE 803.5 FOR | | | THE GROUP AND LOCATION DESIGNATED. | | | INTERIOR WALL AND CEILING FINISH | | | MATERIALS, OTHER THAN TEXTILES, TESTED | | | IN ACCORDANCE WITH NFPA 286 AND MEETING | | | THE ACCEPTANCE . | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-12-01 |
Time |
14:20 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-12-01 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2005-12-01 00:00:00 | NEED TO SHOW ARC-FAULT BREAKER(S) FOR | | | THE BEDROOM. | | | | | | NEED PANEL SCHEDULE | | | | | | BATHROOM NEEDS GFI. | | | | | | NEED RISER DIAGRAM FOR THE SERVICE. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-11-30 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-11-30 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-11-30 |
Time |
13:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-12-05 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-11-30 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2005-11-30 00:00:00 | TO "BOB"#2 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2005-12-05 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2005-12-05 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | NO MECHANICAL WORK SHOWN ON PLANS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-03 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-12-03 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-12-03 |
Time |
06:34 |
Sent To |
|
|
| Notes |
| 2005-12-03 00:00:00 | PLUMBING PLAN REVIEW FBC 2004 | | | DENIED | | | SEC 106.3.5.4 (9) ISOMETRIC DRAWING. | | | SHOW EXISTING DWV CAP OFF FOR | | | DEMOLITION. | | | SHOW NEW LAY OUT AND TIE IN TO EXISTING | | | DWV. | | | QUESTIONS CONTACT 561-805-6692 |
|
|
|