| Plan Review Stops For Permit 05110892 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-03-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-06 |
Time |
13:55 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-03-06 |
Time |
11:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-16 |
Time |
10:01 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-02-16 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2006-02-16 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE.TYPE VI | | | CONSTRUCTION NO LONGER EXISTS UNDER THE | | | NEW CODE.CHECK PLANS AND CORRECT CODE | | | SECTIONS AS NEEDED AND CHANGE TO THE | | | CORRECT CONSTRUCTION TYPE. | | | | | | 4.SOILS REPORT SHALL REFERENCE THE | | | 2004 FBC.RESUBMIT A SOILS REPORT | | | REFERENCING THE 2004 CODE. | | | | | | A.ALL PRODUCT APPROVALS SHALL BE | | | APPROVED BY THE FOLLOWING. | | | 106.3.3 WPB AMMENDMENT TO | | | THE 2004 FBCPRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL | | | APPROVAL. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-27 |
Time |
07:57 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-01-27 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2006-01-27 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE.TYPE VI | | | CONSTRUCTION NO LONGER EXISTS UNDER THE | | | NEW CODE. | | | | | | 4.SOILS REPORT SHALL REFERENCE THE | | | 2004 FBC.SOILS REPORT TO RESUBMITTED. | | | | | | NEW COMMENT:106.3.3 WPB AMMENDMENT TO | | | THE 2004 FBCPRODUCT APPROVALS. THOSE | | | PRODUCTS WHICH ARE REGULATED BY DCA RULE | | | 9B-72 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL | | | APPROVAL. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-03 |
Time |
09:53 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2006-01-03 |
Time |
09:47 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 4.ENERGY CALCS AND SOILS REPORT SHALL | | | REFERENCE THE 2004 FBC | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-27 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-27 |
Time |
18:57 |
Sent To |
PC |
|
| Notes |
| 2006-06-27 00:00:00 | REV FOR ELECTRICAL LAYOUT IN HOUSE | | | ONLY, NOT A REVISION FOR SERVICE RISER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-05-11 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-05-11 |
Time |
17:49 |
Rev Time |
1.00 |
| Received By |
jleahy |
Date |
2006-05-11 |
Time |
17:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
19:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-08 |
Time |
18:40 |
Sent To |
B |
|
| Notes |
| 2006-02-08 00:00:00 | | | | | | | ** SERVICE REVISED FOR THE THIRD TIME, | | | NOW DOES NOT SHOW ANY MAIN DISCONECTS | | | OUTDSIDE, THIS IS OK, HOWEVER AN | | | "EQUIPMENT GROUNDING CONDUCTOR" IS STILL | | | SHOWN FROM METER TO THE MAIN BRKR PANELS | | | . | | | PLEASE SEE 250.6,250.24, "EQUIPMENT | | | GROUNDING CONDUCTORS" ARE ONLY INSTALLED | | | "AFTER" THE FIRST MEANS OF DISCONNECT. | | | ** PLEASE KNOW, THIS WAS REDLINED ON | | | PLANS AND NO NEED FOR CORRECTIONS OR | | | CHANGES ARE NEEDED AT THIS TIME. | | | PLEASE MAKE THIS CORRECTION IF PLANS ARE | | | SUBMITTED IN FOR REVISIONS BEFORE ROUGH | | | ELECTRICAL INSPECTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-24 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-23 |
Time |
19:05 |
Sent To |
M |
|
| Notes |
| 2006-01-24 00:00:00 | ********* UNSAT ********** | | | | | | 1)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | FOR POOL PANEL WITH POOL PANEL SCHEDULE. | | | PLEASE SEE RISER INDICATES 100A OCP, AND | | | FEEDERS FOR 100A ALSO, HOWEVER PLEASE | | | SEE PANEL "B" SHOWS FEED AT 60A'S, AND | | | POOL PANEL IS SHOWN AS 60A'S? | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE POOL PANEL SHOWS A | | | "GAS" POOL HEATER NOW, AND SHOWS A 4KW | | | LOAD AND SHOWN AT 125%? | | | PLEASE SEE ORIGINAL PLANS CALLED FOR AN | | | ELECTRICAL HEAT PUMP TYOE OF POOL HEATER | | | WHICH REQUIRES THE CONTINUOUS LOADS AT | | | 125% AND THE OCP AT 125%. IF THIS IS GAS | | | THEN THE LOADSSHOULD BE ADJUSTED. THIS | | | WOULD ALSO AFFECT HOW LARGE THE POOL | | | PANEL WOULD NEED TO BE. PLEASE SEE NOTE | | | #1 AND #2 FROM PREVIOUS REVIEW. | | | 215.5 | | | | | | 3)NOTE: PLEASE LIST THE REQUIRED ARC | | | FAULT PROTECTED CIRCUITS ON PANEL | | | SCHEDULE. PLEASE SEE 2002 NEC 210.12 | | | WHICH REQUIRES ARC FAULT PROTECTION FOR | | | ALL "OUTLETS" IN BEDRMS. LTS, SD'S, | | | RECEPTS, FANS ETC. | | | PLEASE SEE THIS WAS NOT ACOMMENT ON | | | PREVIOUS REVIEW,AS THIS WAS ON THE PLANS | | | AND HAS NOW BEEN REMOVED. PLEASE SEE | | | VOIDED ELECTRICAL SHEETS FROM FIRST | | | REVIEW. | | | | | | 4)NOTE: PLEASE SEE OCP FOR AHU #2 ON | | | PANEL "B" WAS ADJUSTED AND INCREASED TO | | | MEET 424.3B , HOWEVER PLEASE SEE AWG IS | | | STILL SHOWN AS #8. PLEASE SEE AWG SHOWN | | | ON PANEL "A" FOR AHU #1 IS CORRECT. | | | 310.16, 240.4 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2006-01-23 00:00:00 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-12 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-12 |
Time |
10:15 |
Sent To |
M |
|
| Notes |
| 2005-12-12 00:00:00 | ******** UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE MIN OCP FOR POOL HEAT | | | PUMP SHALL BE SIZED AT 125%. 680.9 | | | | | | 2)NOTE: PLEASE SEE THE LOAD ON POOL | | | PANEL EXCEEDS THE 60A OCP FEEDING THIS | | | PANEL. PLEASE SEE POOL PANEL AND FEEDERS | | | ARE ALREADY SHOWN AS 100A? | | | PLEASE CORRELATE. | | | 240.4,215.5 | | | | | | 3)NOTE: PLEASE SEER MISSING HALLWAY | | | RECEPT PER 210.52H | | | | | | 4)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52. PLEASE SEE ONE SET OF PLANS HAVE | | | BEEN REDLINED WITH MANY OF THESE | | | LOCATIONS INDICATED. | | | | | | 5)NOTE: PLEASE SEE PLANS DO NOT SEEM TO | | | INDICATE THE POOL PANEL. PLEASE SHOW. | | | 215.5 | | | | | | 6)NOTE:PLEASE SEE MISSING GFI IN CABANA | | | BATH AS REQUIRED PER 210.52D, 210.11C3, | | | 210.8A1 | | | | | | 7)NOTE: PLEASE CORRELATE THE # OF GDO | | | CIRCUITS ON PANEL SCHEDULE WITH THE | | | ACTUAL # NEEDED ON PLANS. PLEASE SEE | | | OTHER GARAGE. THREE GDO'S ON PLANS AND | | | ONLY TWO CIRCUITS ON PANEL SCHEDULE. | | | | | | 215.5, 430.24. TABLES). | | | | | | 8)NOTE: PLEASE SEE DISC'S FOR A/C CU | | | UNITS SHALL MEET 110.26 | | | | | | 9)NOTE: PLEASE SEE NFPA -72 11-8.3.5 | | | WHICH REQUIRES ALL SD'S TO BE INSTALLED | | | WITH-IN 12" OF A FLAT CEILING AREA. | | | PLEASE SEE "TRAY" CEILING AREA WOULD | | | REQUIRE TO THESE SD'S LOCATED AT THESE | | | AREAS IF THEY ARE 12" OR MORE HIGHER | | | THAN | | | SURROUNDING CEILING AREA. SEE REDLINED | | | PLANS. | | | | | | | | | 10)NOTE: PLEASE SEE MIN OCP FOR AHU #1 | | | IS BE SIZED AT 125% PER 424.3B. | | | | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | FROM PLANS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. | | | ONE COPYOF OLD/VOIDED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | ** PLEASE SEE ANY OTHER POSSIBLE | | | COMMENTS FROM OTHER REVIEWS WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-25 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-25 |
Time |
17:15 |
Sent To |
E |
|
| Notes |
| 2006-06-25 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-22 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-22 |
Time |
15:34 |
Sent To |
B |
|
| Notes |
| 2006-02-22 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-06 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-06 |
Time |
14:58 |
Sent To |
E |
|
| Notes |
| 2006-02-06 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-20 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-20 |
Time |
12:05 |
Sent To |
E |
|
| Notes |
| 2006-01-20 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
10:27 |
Sent To |
E |
|
| Notes |
| 2005-12-10 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-03 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-11-29 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2005-11-29 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-24 |
Time |
10:22 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-01-24 |
Time |
10:22 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-12 |
Time |
13:35 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-12-12 |
Time |
13:35 |
Sent To |
P |
|
| Notes |
| 2005-12-12 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON | | | FORM 600A-04 (2004), PER 2004 FBC | | | 13-600. | | | 2) PLEASE SHOW SIZE OF RETURN AIR PLENUM | | | DUCT OPENING IN A/H CLOSET. | | | 3) NEED TO SHOW BTU'S FOR A/C#2 ON | | | PLANS. | | | 4) NEED TO FILE NOTICE OF COMMENCEMENT. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-13 |
Time |
14:16 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-13 |
Time |
14:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-07 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-07 |
Time |
17:00 |
Sent To |
I |
|
| Notes |
|
|