Plan Review Details - Permit 05110683
Plan Review Stops For Permit 05110683
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-12-23 Cont ID  
Sent By jwitmer Date 2005-12-23 Time 09:28 Rev Time 0.77
Received By jwitmer Date 2005-12-22 Time 14:52 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-01 Cont ID  
Sent By jwitmer Date 2005-12-01 Time 08:16 Rev Time 0.00
Received By   Date 2005-12-01 Time 07:19 Sent To PC
Notes
2005-12-01 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05110683
 ADD: 515 N FLAGLER # 1701 A
 CONT: CENTEX
 TEL: (561)478-0381
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PERMIT APPLICATION IS FOR NEW WORK,
 THE REMODELING OF A TENANT SPACE
 WHEREAS THE PLANS ARE FOR DEMOLITION
 ONLY. PLEASE CORRECT .
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-12-23 Cont ID  
Sent By jleahy Date 2005-11-28 Time 07:58 Rev Time 0.15
Received By jleahy Date 2005-11-28 Time 07:15 Sent To  
Notes
2005-11-28 00:00:00NO ELECTRICAL WORK SHOWNPLANS SAY DEMO
  
 PERMIT SAYS INTERIOR REMODELJL

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2005-12-21 Cont ID  
Sent By mcarsill Date 2005-12-21 Time 12:15 Rev Time 0.00
Received By mcarsill Date 2005-12-21 Time 11:34 Sent To  
Notes
2005-12-21 00:00:001. SEPERATE PLANS AND PERMITS REQUIRED
 FOR THE FIRE SPRINKLER SYSTEM REMODEL.
  
 2. SEPERATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM SYSTEM REMODEL.
  
 3. RENOVATION, DEMOLITION, AND
 CONSTRUCTION TO COMPLY WITH NFPA 241.
  
 4. EXITS SHALL REMAIN CLEAR AND
 UNOBSTRUCTED.
  
 5. DEBRIS SHALL BE REMOVED FROM THE SITE
 DAILY.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
 804-4709

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-11-28 Cont ID  
Sent By nmccray Date 2005-11-28 Time 10:51 Rev Time 0.00
Received By nmccray Date 2005-11-28 Time 10:45 Sent To  
Notes
2005-11-28 00:00:00DENIED:
  
 1) THE PERMIT APPLICATION DESCRIBE
 TENANT RENOVATION AND INTERIOR REMODEL.
 ONLY DEMOLITION PLANS IN THE PACKET.
  
 NATE MCCRAY, ASSISTANT FIRE MARSHAL
 561-804-4754

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-19 Cont ID  
Sent By adarroug Date 2005-12-19 Time 16:49 Rev Time 0.00
Received By adarroug Date 2005-12-19 Time 16:49 Sent To  
Notes
2005-12-19 00:00:00TO "BOB"#5

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-23 Cont ID  
Sent By jwitmer Date 2005-12-01 Time 09:28 Rev Time 0.00
Received By jwitmer Date 2005-11-22 Time 15:20 Sent To  
Notes
2005-11-22 00:00:00TO "BOB"#13

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2005-12-20 Cont ID  
Sent By tgordon Date 2005-12-20 Time 12:15 Rev Time 0.45
Received By tgordon Date 2005-12-20 Time 12:15 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-11-28 Cont ID  
Sent By hmoser Date 2005-11-28 Time 14:47 Rev Time 0.00
Received By hmoser Date 2005-11-28 Time 14:42 Sent To  
Notes
2005-11-28 00:00:00DEMO PLANS NOT REQUIRED FOR MECHANICAL.
 HAEOLD MOSER 561-805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-12-22 Cont ID  
Sent By jleech Date 2005-12-22 Time 07:20 Rev Time 0.00
Received By jleech Date 2005-12-22 Time 07:20 Sent To  
Notes
2005-12-22 00:00:00PROVISO;
 PLUMBING CONTRACTOR TO SET FIXTURES FOR
 DRY MODEL, PERMIT REQUIRED. PLUMBING
 INSPECTOR WILL CHECK FOR COMPLIANCE WITH
 THE U.S FAIR HOUSING ACT.