Plan Review Details - Permit 05110633
Plan Review Stops For Permit 05110633
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-05-16 Cont ID  
Sent By alange Date 2006-05-16 Time 12:52 Rev Time 0.50
Received By alange Date 2006-05-16 Time 12:52 Sent To  
Notes
2006-05-16 00:00:00SUBMITTAL OF PRODUCT APPROVAL RESTAMP OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-03-15 Cont ID  
Sent By alange Date 2006-03-15 Time 15:53 Rev Time 0.50
Received By alange Date 2006-03-15 Time 15:53 Sent To  
Notes
2006-03-15 00:00:00SUBMITTAL RECEIVED FOR BUCKS OKALANGE

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-02-23 Cont ID  
Sent By alange Date 2006-02-23 Time 12:49 Rev Time 0.50
Received By alange Date 2006-02-23 Time 12:49 Sent To  
Notes
2006-02-23 00:00:00REV. OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-12-28 Cont ID  
Sent By alange Date 2005-12-28 Time 08:12 Rev Time 1.00
Received By alange Date 2005-12-28 Time 07:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By btrobaug Date 2006-09-19 Time 11:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2006-09-07 Cont ID  
Sent By btrobaug Date 2006-09-07 Time 11:20 Rev Time 0.50
Received By btrobaug Date 2006-09-07 Time 10:26 Sent To PC
Notes
2006-09-07 00:00:00 
  
 NONCOMPLIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THERE ARE NEW APPLIANCES IN THE
 KITCHEN ( ICE MAKER, WINE COOLER) THAT
 AREN'T LISTED IN THE LOAD CALCULATION OR
 ON THE PANEL SCHEDULE. ALSO THE
 DISHWASHER AND DISPOSAL, ALTHOUGH
 EXISTING, NUST BE INCLUDED. ALL LOADS
 MUST BE CALCULATED TO DETERMINE THE
 SERVICE IS ADEQUITE. SEE 220.31., 215.5.
  
 2} A HEAT DETECTOR MUST BE ADDED IN THE
 KITCHEN TO COMPLY WITH 313.1.1, FBC.
  
 3} THE RECEPTACLE AT THE KITCHEN ISLAND
 MUST BE GFI PER 210.8(A)(6).
  
 4} THERE IS A 50 AMP DISCONNECT SHOWN ON
 THE KITCHEN WALL WITH NO DESIGNATION.
 PLEASE INDICAE IT'S USE.
  
 5} THE PANEL SCHEDULE MUST HAVE OCP AND
 WIRE SIZES INDICATED FOR THE BRANCH
 CIRCUITS AND FEEDERS TO COMPLY WITH
 106.3.5.4 FBC.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-07-06 Cont ID  
Sent By btrobaug Date 2006-07-06 Time 13:40 Rev Time 0.50
Received By btrobaug Date 2006-07-06 Time 13:00 Sent To P
Notes
2006-07-06 00:00:00 
  
 THE PLANS SUBMITTED INDICATE THE REVISED
 (CLOUDED AREA) IS THE ENTIRE RESIDENCE.
 PLEASE SHOW COMPLIANCE WITH THE 2002
 NEC. FOR THE ENTIRE RESIDENCE. INCREASE
 THE VALUE OF THE WORK AT THE FRONT
 COUNTER, FROM THE ORIGINALLY PROPOSED
 WORK TO THE NEW SCOPE.
  
 IF THE ENTIRE SCOPE HAS NOT BEING
 REVISED AS INDICATED BY THE CLOUDED
 AREA, PLEASE CLOUD THE CHANGES MADE
 SINCE THE APRIL 4,2006 REVIEW.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-04-06 Cont ID  
Sent By jleahy Date 2006-04-06 Time 10:30 Rev Time 0.45
Received By jleahy Date 2006-04-06 Time 10:30 Sent To P
Notes
2006-04-06 00:00:00PUT IN RESULTS FOR P PETTYJL

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-07 Cont ID  
Sent By btrobaug Date 2006-02-07 Time 11:58 Rev Time 0.50
Received By btrobaug Date 2006-02-06 Time 15:08 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-12-23 Cont ID  
Sent By btrobaug Date 2005-11-28 Time 06:20 Rev Time 0.50
Received By btrobaug Date 2005-11-28 Time 06:06 Sent To M
Notes
2005-11-28 00:00:00 
  
 AN ELECTRICAL PERMIT IS REQUIRED FOR
 THIS WORK.
  
 IF THERE ARE ANY QUESTIIONS PLEASE HAVE
 MR. PAINE CALL ME.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-08-22 Cont ID  
Sent By adarroug Date 2006-08-22 Time 17:52 Rev Time 0.00
Received By adarroug Date 2006-08-22 Time 17:52 Sent To E
Notes
2006-08-22 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-06-27 Cont ID  
Sent By adarroug Date 2006-06-27 Time 08:45 Rev Time 0.00
Received By adarroug Date 2006-06-27 Time 08:45 Sent To E
Notes
2006-06-27 00:00:00TO "BTROBAUGH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-12 Cont ID  
Sent By adarroug Date 2006-05-12 Time 14:45 Rev Time 0.00
Received By adarroug Date 2006-05-12 Time 14:45 Sent To B
Notes
2006-05-12 00:00:00TO "ALANGE" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-04-03 Cont ID  
Sent By adarroug Date 2006-04-03 Time 10:47 Rev Time 0.00
Received By adarroug Date 2006-04-03 Time 10:47 Sent To B
Notes
2006-04-03 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-01-28 Cont ID  
Sent By adarroug Date 2006-01-28 Time 16:44 Rev Time 0.00
Received By adarroug Date 2006-01-28 Time 16:44 Sent To E
Notes
2006-01-28 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-28 Cont ID  
Sent By alange Date 2005-12-28 Time 08:12 Rev Time 0.00
Received By alange Date 2005-11-22 Time 14:03 Sent To  
Notes
2005-11-22 00:00:00TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2006-04-06 Cont ID  
Sent By tgordon Date 2006-04-06 Time 15:30 Rev Time 0.20
Received By tgordon Date 2006-04-06 Time 15:30 Sent To  
Notes
2006-04-06 00:00:00REVISION TO FLOOR PLAN SHOWING
 RELOCATION OF STOVE AND HOOD.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-02-10 Cont ID  
Sent By tgordon Date 2006-02-10 Time 10:30 Rev Time 0.30
Received By tgordon Date 2006-02-10 Time 10:30 Sent To B
Notes
2006-02-10 00:00:00MECH. PLANS SUBMITTED FOR RELOCATION OF
 SOME OF THE SUPPLY AIR GRILLS, MECH.
 CONTRACTOR SIGNED ON.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2005-11-28 Cont ID  
Sent By btrobaug Date 2005-12-23 Time 10:46 Rev Time 0.15
Received By tgordon Date 2005-11-28 Time 07:59 Sent To P
Notes
2005-11-28 00:00:00NO MECH. PLANS OR MECH. CONTRACTOR
 SUBMITTED AT THIS TIME.

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-04-06 Cont ID  
Sent By jleech Date 2006-04-06 Time 13:40 Rev Time 0.00
Received By jleech Date 2006-04-06 Time 13:40 Sent To M
Notes
2006-04-06 00:00:00REVISION; DELETED ICE MAKER AND 2BAR
 SINKS. NEED A GAS REVISION, MOVED STOVE
 TO ISLAND CABINETS.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-02-10 Cont ID  
Sent By jleech Date 2006-02-10 Time 08:50 Rev Time 0.25
Received By jleech Date 2006-02-10 Time 08:50 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-01-09 Cont ID  
Sent By pschmitz Date 2006-01-09 Time 14:08 Rev Time 0.00
Received By pschmitz Date 2006-01-09 Time 14:06 Sent To  
Notes
2006-01-09 00:00:00NO DEAD ENDS, NEW SINK IS GOING TO TUB
 DRAIN.

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-15 Cont ID  
Sent By jleech Date 2005-12-15 Time 09:45 Rev Time 0.33
Received By jleech Date 2005-12-15 Time 09:45 Sent To B
Notes
2005-12-15 00:00:00PAGE TWO IS MISSING. PLUMBING CONTRACTOR
 IS REQUIRED TO DO PLUMBING WORK. HOW IS
 TUB TO BE CAPPED OFF? NO DEAD ENDS IN
 DRAINAGE PIPING LONGER THAN 2 FEET SEE
 FBC-2004 PLUMBING SECTION 704.5.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695