| Plan Review Stops For Permit 05110626 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2006-01-20 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2006-01-20 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | ADDRESS ON APP READS 911/CP READS | | | 917/PAPA HAS NO NUMERIC # ATTACHED TO | | | ADDRESS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-05 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-05 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2007-02-05 13:18:44 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBEXISTING BUILDING CODE 2004 | | | FBC R RESIDENTIAL 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | | | | 1.)THE ANCHORING SPECIFIED IS FOR POURED CONCRETE, | | | YOU STATE THAT SUBSTRATE IS CONCRETE BLOCK.USE THE | | | HOLLOW BLOCK SCHEDULE FOR FILLED CELL APPLICATION. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
F |
Date |
2007-02-01 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-02-01 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-02-01 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2007-02-01 17:10:55 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY | | | | | | ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED, | | | FS713.13. | | | | | | ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN | | | PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE | | | DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY | | | AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED | | | ORIGINALS FAC61G15-23.002. | | | | | | ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION | | | APPROVAL. | | | | | | _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE | | | OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT. | | | | | | ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG. | | | | | | ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS | | | APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A | | | HIGHLIGHTER. | | | | | | ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC | | | R310. | | | | | | ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE | | | SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH | | | CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4 | | | ABOVE. | | | | | | ____9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2). | | | NOTE THAT THE DEFINITION FOR EXPOSURE C HAS CHANGED | | | EFFECTIVE DECEMBER 8, 2006 FBC1609.4. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-01-12 |
|
|
Cont ID |
|
| Sent By |
hpiskura |
Date |
2007-01-12 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
hpiskura |
Date |
2007-01-12 |
Time |
07:32 |
Sent To |
PC |
|
| Notes |
| 2007-01-12 07:34:18 | REVIEWED SURVEY SHOWING TOPOGRAPHIC FOR DRAINAGE AND | | | ELEVATION CERTIFICATE.OKAY. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-17 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-17 |
Time |
15:42 |
Sent To |
P |
|
| Notes |
| 2006-08-17 00:00:00 | NO BUILDING CHANGES |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
N |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-08 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-08-08 |
Time |
09:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-03-13 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-13 |
Time |
15:34 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-03-13 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-09 |
Time |
08:33 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-02-09 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2006-02-09 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE.CHECK ALL CODE | | | SECTIONS SHOWN. | | | | | | 5. BASED ON SBCCI BUILDING VALUATION | | | DATA THE PERMIT VALUE HAS BEEN ADJUSTED | | | TO $155,250.ADDITIONAL PERMIT FEES ARE | | | DUE.SEE ATTACHED INVOICE. | | | | | | 6.ON PRODUCT APPROVAL FOR TAMKO | | | ROOFING, SELECT THE ASSEMBLY THAT WILL | | | BE USED.** PRODUCT APPROVAL IS NOW FOR | | | GAF.SAME COMMENTS APPLIES** | | | | | | 7.SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR LINTELS.ALL | | | PRODUCT APPROVALS SUBMITTED SHALL HAVE | | | THE FOLLOWING STATE PRODUCT APPROVAL | | | ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-27 |
Time |
07:25 |
Rev Time |
3.00 |
| Received By |
alange |
Date |
2005-12-27 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2005-12-27 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 4.SUBMIT TWO COPIES OF ENERGYCALCS TO | | | THE 2004 FBC | | | | | | 5. BASED ON SBCCI BUILDING VALUATION | | | DATA THE PERMIT VALUE HAS BEEN ADJUSTED | | | TO $155,250.ADDITIONAL PERMIT FEES ARE | | | DUE.SEE ATTACHED INVOICE. | | | | | | 6.ON PRODUCT APPROVAL FOR TAMKO | | | ROOFING, SELECT THE ASSEMBLY THAT WILL | | | BE USED. | | | | | | 7.SUBMIT TWO COPIES OF PRODUCT | | | APPROVALS FOR STRAPS AND LINTELS.ALL | | | PRODUCT APPROVALS SUBMITTED SHALL HAVE | | | THE FOLLOWING STATE PRODUCT APPROVAL | | | ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 8.SHOW METHOD OF ROOD DRAINAGE R-801.3 | | | AND 803.4 | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
P |
Date |
2006-09-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-30 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-30 |
Time |
18:22 |
Sent To |
PC |
|
| Notes |
| 2006-09-30 00:00:00 | REV OK. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-08 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-08 |
Time |
11:28 |
Sent To |
PC |
|
| Notes |
| 2006-09-08 00:00:00 | LTR ALLOWING THE USE OF #14 FOR 15A | | | OCP/ BRKR CIRCUITS, STILL NEEDS TO | | | REVISE PANEL SCHEDULE BEFORE FINAL. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-25 |
Time |
09:10 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-08-25 |
Time |
09:10 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-14 |
Time |
18:11 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-14 |
Time |
18:02 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-23 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-23 |
Time |
13:14 |
Sent To |
M |
|
| Notes |
| 2006-07-23 00:00:00 | ****** UNSAT ********* | | | | | | ** IMPORTANT*** | | | | | | WHEN SUBMITTING PLANS, PLEASE BE SURE TO | | | SUBMIT TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. THE PLANS WERE SUBMITTED IN | | | PEICES OF INDIVIDUAL SHEETS. THESE SETS | | | WERE MADE THIS TIME FOR THE REVIEW | | | PROCESS. PLEASE KNOW, THIS HELPS IN THE | | | REVIEW PROCESS. | | | | | | | | | 1) NOTE: PLEASE SEE ALL PLANS REVISING | | | ANY PLANS ONRECORD SHALL CONTAIN | | | PRINTED NAMES AND SIGNATURES OF ALL | | | DESIGN PROFESSSIONALS OF RECORD. PLEASE | | | SEE THIS ALSO INCLUDES PLANS WHICH ARE | | | NOTE SIGNED, DATED AND SEALED BY THE | | | ENGINEER OF RECORD. | | | | | | FBC 106.1.2, FS 471.025 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-14 |
Time |
14:56 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-07-14 |
Time |
14:25 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-01 |
Time |
20:25 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-01 |
Time |
20:14 |
Sent To |
B |
|
| Notes |
| 2006-03-01 00:00:00 | REDLINED LOAD CALCS, AS COMPRESSOR IS | | | STILL SHOWN WITH THE 10KW, LOADS | | | WHERE-AS THE LARGEST LOAD IS THE AHU. | | | NO CORRECTION NEEDED AT THIS TIME. | | | PLEASE CORRECT IF PLANS ARE REVISED | | | DURING CONSTRUCTION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-31 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-31 |
Time |
08:07 |
Sent To |
M |
|
| Notes |
| 2006-01-31 00:00:00 | ********UNSAT ********* | | | | | | | | | 1)NOTE: PLEASE SEE OCP AND AWG FOR WATER | | | HEATER IS SHOWN TOO LARGE. MAX | | | 150%.422.11E | | | | | | 2)NOTE: PLEASE SEE NO DISCONNECT SHOWN | | | ON THE OUTSIDE OF HOUSE AS SHOWN ON | | | RISER. | | | 215.5 | | | | | | 3)NOTE: PLEASE SEE MISSING SD IN THE | | | IMMEDIATE AREA LEADING TO FLR ABOVE PER | | | NFPA-72 11.5.1.1 (FIRST FLR) | | | | | | 4)NOTE: PLEASE SEE LOAD CALCULATIONS | | | INDICATE THE COMPRESSOR AS PART OF THE | | | LOAD CALCULATIONS, WHEN THE AHU UNIT | | | LOAD IS THE LARGER LOAD. | | | 215.5 | | | | | | 5)NOTE: PLEASE SEE NOTES FOR ELECTRICAL | | | STILL MENTIONS SD'S TO BE WIRED TO THE | | | BATH OR KITCHEN LTS, HOWEVER PLEASE SEE | | | BATH IS SHOWN AS A DEDICATED CIRCUIT | | | WHICH DOES NOT PERMIT ANY OTHER | | | ELECTRICAL ON THAT CIRCUIT. PLEASE ALSO | | | SEE NO ARC FAULT PROTECTION IS SHOWN FOT | | | KITCHEN LTS AS NOTED ON FIRST REVIEW. | | | | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-12 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-12 |
Time |
08:01 |
Sent To |
M |
|
| Notes |
| 2005-12-12 00:00:00 | *********** UNSAT ************* | | | | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | 2)NOTE: PLEASE SEE MISSING RECEPTS | | | PER 210.52 | | | | | | 3)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52C3 | | | | | | 4)NOTE: COULD NOT LOCATE COND UNIT, TO | | | VERIFY DISCONNECTING MEANS. 440.11 | | | | | | 5)NOTE: PLEASE SEE PLANS SHOW SD IN | | | BATHROOM AND OUTSIDE BATHRM DOOR WITHIN | | | 3'. PLEASE SEE THIS IS NOT PERMITTED. | | | NFPA-72 11.8.3.5 | | | PLEASE ALSO SEE ONE BEDRM WHERE SD LOOKS | | | TO BE JUST OUTSIDE THE DOOR, WHERE | | | REQUIRED TO BE LOCATED INSIDE. THESE ARE | | | REDLINED ON PLANS FOR CLARIFICATION. | | | | | | 6)NOTE: PLEASE SEE MISSING DEDICATED GDO | | | CIRCUIT IN PANELAND IN LOAD CALCS. | | | 215.5,230.24, 220 ETC . | | | | | | 7)NOTE: PLEASESEE THAT PLANS SPECIFY | | | THE CODE WHICH IS IN EFFECT.(2002) | | | PLEASE ALSO SEE PLANS CALL FOR ALL TO | | | MEET CITY OF RIVERA BEACH? PLEASE SEE | | | THIS PROJECT IS LCATED IN THE CITY OF | | | WEST PALM BEACH. | | | 215.5 | | | | | | 8)NOTE: PLEASE SEE 424.3B FOR MIN OCP | | | FOR AHU 10KW HEAT. | | | 50A IS NOT LARGE ENOUGH. | | | | | | 9)NOTE: PLEASE SEE 210.52D,210.11C3, | | | WHICH REQUIRES ALL BATH CIRCUITS (S) TO | | | BE 20A AND #12 AWG. PLEASE SEE 20A OCP | | | SHOWN ON #14 AWG ETC. | | | | | | 10)NOTE: PLEASE SEE NOTES ON PLANS | | | INDICATE THE SD'S WIRED TO BATH AND | | | KITCHEN LIGHTING CIRCUIT. PLEASE SEE | | | SD'S ARE ALL REQUIRED TO BE WIRED | | | "IN-LINE" (NFPA 72_) AND ARE ALL | | | REQUIRED TO BE AFCI PROTECTED AS PER | | | 210.12 OF THE 2002 NEC. | | | PLEASE ADJUST NOTE, UNLESS AFCI BRKRS | | | ARE GOING TO BE NOTED FOR KITCHEN LTS | | | AND BATH LTS. | | | PLEASE CALL TO GO OVER THIS SCENERIO. | | | | | | 11)NOTE: PLEASE SEE 210.11C2 WHICH | | | REQUIRES LAUNDRY/WASHER CIRCUITS TO HAVE | | | A MIN OF 1.5KW FOR EACH. PLEASE SEE | | | PLANS INDICATE LESS VA. | | | 215.5 | | | | | | 12)NOTE: PLEASE SEE LOADS FOR SM APPL, | | | TO BE A MIN OF 1500VA. | | | 210.11C3 | | | | | | 13)NOTE: PLEASE SEE MANY OTHER LOADS | | | INDICATED ON PANEL SCHEDULE DO NOT SEEM | | | TO CORRELATE. | | | PLEASE ALSO SEE LIGHTING LOADS ON 15A | | | CIRCUITS, SHOWN EXCEED RATING OF | | | CIRCUITS.1440 VA 15A. 1920VA 20A. | | | 215.5 | | | | | | | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | TWO COMPLETE SETS FOR REVIEW AND | | | STAMPING. | | | PLEASE SUBMIT ONE COPY OF OLD/VOIDED | | | SHEETS FOR REFERENCE. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER TRADES WHICH MAY AFFECT ELECTRICAL | | | PLANS. | | | | | | **PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW AND IF THERE ARE ANY | | | QUESTIONS, PLEASE DO NOT HESITATE IN | | | CONTACTING THIS OFFICE. | | | | | | **PLEASE SEE MANY OF THE ABOVE ITEMS | | | HAVE BEEN REDLNED ON PLANS WHICH ARE | | | NOTED. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-02-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-08 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-08 |
Time |
09:18 |
Sent To |
B |
|
| Notes |
| 2007-02-08 09:20:16 | TO "SHILL" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-17 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-17 |
Time |
09:58 |
Sent To |
B |
|
| Notes |
| 2007-01-17 09:59:26 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-28 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-28 |
Time |
11:41 |
Sent To |
B |
|
| Notes |
| 2006-12-28 11:42:56 | TO "LMARTINEZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-28 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-28 |
Time |
10:18 |
Sent To |
E |
|
| Notes |
| 2006-09-28 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-28 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-28 |
Time |
11:23 |
Sent To |
E |
|
| Notes |
| 2006-08-28 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-11 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-11 |
Time |
09:05 |
Sent To |
E |
|
| Notes |
| 2006-08-11 00:00:00 | TO "DPALMER' DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-21 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-21 |
Time |
15:12 |
Sent To |
E |
|
| Notes |
| 2006-07-21 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-14 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-14 |
Time |
14:01 |
Sent To |
E |
|
| Notes |
| 2006-07-14 00:00:00 | TO "BTROBAUG" DESK/PER "RBROWN" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-01 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-01 |
Time |
08:44 |
Sent To |
E |
|
| Notes |
| 2006-03-01 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-28 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-28 |
Time |
15:48 |
Sent To |
E |
|
| Notes |
| 2006-01-28 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-23 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-23 |
Time |
14:01 |
Sent To |
Z |
|
| Notes |
| 2006-01-23 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-10 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-10 |
Time |
10:23 |
Sent To |
E |
|
| Notes |
| 2005-12-10 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-27 |
Time |
07:34 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-11-22 |
Time |
15:06 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2006-07-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-26 |
Time |
08:28 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-07-26 |
Time |
08:28 |
Sent To |
P |
|
| Notes |
| 2006-07-26 00:00:00 | MECHANICAL REVISION NOT TO BE REVIEWED | | | BY CUSTOMERS REQUEST (MARVELL BORNDS). |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-01 |
Time |
13:30 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2006-02-03 |
Time |
14:08 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-31 |
Time |
10:09 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2005-12-12 |
Time |
14:18 |
Sent To |
P |
|
| Notes |
| 2005-12-12 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON | | | FORM 600A-04 (2004), PER 2004 FBC | | | 13-600. | | | 2) NEED TO SHOW THE LOCATION OF THE | | | CONDENSER UNIT ON THE PLANS. | | | 3) NEED TO SHOW DRAIN LINE, OR PUMP ON | | | PLANS. | | | 4) BEDROOM #2 HAS AN 8" SUPPLY AIR DUCT | | | AND NEEDS A 10" RETURN TRANSFER DUCT, | | | PER 2004 FBC/R M1602.4 . | | | 5) CLOTHES DRYER EXHAUST NEEDS TO BE | | | SHOWING ON PLANS. | | | 6) IS AHU IN THE CLOSET OR THE ATTIC | | | PLEASE SHOW ON PLANS. | | | 7) NEED TO SHOW THE SIZE OF THE RETURN | | | AIR GRILL IN THE 2ND. FLOOR HALLWAY. | | | 8) PLEASE SHOW COPPER LINE SIZES ON | | | PLANS. | | | IF YOU HAVE ANY QUESTIOUS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-08-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-21 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-21 |
Time |
09:23 |
Sent To |
|
|
| Notes |
| 2006-08-21 00:00:00 | REVISION; | | | ADDED LAUNDRY TUB, DELETED ONE | | | LAVATORY. REVISED FLOOR PLAN AND | | | SANITARY RISER DIAGRAM TO SHOW CHANGES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-08-08 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-08-08 |
Time |
07:12 |
Sent To |
B |
|
| Notes |
| 2006-08-08 00:00:00 | DENIED; | | | 1.SEE ELECTRICAL PLAN REVIEWER'S NOTES. | | | 2.SECOND FLOOR SHOWER IS NOT VENTED. | | | (TOILET FLUSHES PAST SHOWER BEFORE VENT) | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-07 |
Time |
15:08 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-02-07 |
Time |
15:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-03 |
Time |
14:08 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-12-13 |
Time |
13:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-15 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-15 |
Time |
08:58 |
Sent To |
B |
|
| Notes |
| 2006-01-27 00:00:00 | PLANS RETURNED TO INCOMING, ALREADY | | | APPROVED ON 12/15/05.NO CHANGES. | | 2005-12-15 00:00:00 | 10FT WIDE DRIVEWAY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-07 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-07 |
Time |
16:45 |
Sent To |
I |
|
| Notes |
| 2005-12-07 00:00:00 | DENIED, | | | 1. MUST PROVIDE THE DIMENSION OF | | | PROPOSED DRIVEWAY (LENGTH & WIDTH) ON | | | TWO COPY OF SURVEY. | | | 2. MUST MAINTAIN 1000SQ FT OR 75% OF | | | LANDSCAPE WHICHEVER IS LESS WITHIN THE | | | FIRST 25FT FRONT SETBACK. | | | | | | NOTE: CAN ONLY HAVE 312.5SQ FT OF | | | DRIVEWAY WITHIN THE FIRST 25FT FRONT | | | SETBACK (12.5FT) | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|