Plan Review Details - Permit 05110626
Plan Review Stops For Permit 05110626
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2006-01-20 Cont ID  
Sent By ptjomsto Date 2006-01-20 Time 11:02 Rev Time 0.00
Received By ptjomsto Date 2006-01-20 Time 11:02 Sent To  
Notes
2006-01-20 00:00:00ADDRESS ON APP READS 911/CP READS
 917/PAPA HAS NO NUMERIC # ATTACHED TO
 ADDRESS

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status F Date 2007-02-05 Cont ID  
Sent By shill Date 2007-02-05 Time 13:17 Rev Time 0.00
Received By shill Date 2007-02-05 Time 13:17 Sent To  
Notes
2007-02-05 13:18:44****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBEXISTING BUILDING CODE 2004
 FBC R RESIDENTIAL 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
  
 1.)THE ANCHORING SPECIFIED IS FOR POURED CONCRETE,
 YOU STATE THAT SUBSTRATE IS CONCRETE BLOCK.USE THE
 HOLLOW BLOCK SCHEDULE FOR FILLED CELL APPLICATION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2007-02-01 Cont ID  
Sent By shill Date 2007-02-01 Time 17:10 Rev Time 0.00
Received By shill Date 2007-02-01 Time 17:10 Sent To  
Notes
2007-02-01 17:10:55****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY
 AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 ____9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2).
 NOTE THAT THE DEFINITION FOR EXPOSURE C HAS CHANGED
 EFFECTIVE DECEMBER 8, 2006 FBC1609.4.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-01-12 Cont ID  
Sent By hpiskura Date 2007-01-12 Time 07:32 Rev Time 0.00
Received By hpiskura Date 2007-01-12 Time 07:32 Sent To PC
Notes
2007-01-12 07:34:18REVIEWED SURVEY SHOWING TOPOGRAPHIC FOR DRAINAGE AND
 ELEVATION CERTIFICATE.OKAY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status N Date 2006-08-17 Cont ID  
Sent By alange Date 2006-08-17 Time 15:42 Rev Time 0.00
Received By alange Date 2006-08-17 Time 15:42 Sent To P
Notes
2006-08-17 00:00:00NO BUILDING CHANGES

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status N Date 2006-08-08 Cont ID  
Sent By alange Date 2006-08-08 Time 11:08 Rev Time 0.00
Received By alange Date 2006-08-08 Time 09:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-03-13 Cont ID  
Sent By alange Date 2006-03-13 Time 15:34 Rev Time 1.50
Received By alange Date 2006-03-13 Time 15:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-02-09 Cont ID  
Sent By alange Date 2006-02-09 Time 08:33 Rev Time 1.50
Received By alange Date 2006-02-09 Time 08:19 Sent To  
Notes
2006-02-09 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 3.ALL PLANS SUBMITTED AFTER OCTOBER,
 1, 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.CHECK ALL CODE
 SECTIONS SHOWN.
  
 5. BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUE HAS BEEN ADJUSTED
 TO $155,250.ADDITIONAL PERMIT FEES ARE
 DUE.SEE ATTACHED INVOICE.
  
 6.ON PRODUCT APPROVAL FOR TAMKO
 ROOFING, SELECT THE ASSEMBLY THAT WILL
 BE USED.** PRODUCT APPROVAL IS NOW FOR
 GAF.SAME COMMENTS APPLIES**
  
 7.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR LINTELS.ALL
 PRODUCT APPROVALS SUBMITTED SHALL HAVE
 THE FOLLOWING STATE PRODUCT APPROVAL
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-27 Cont ID  
Sent By alange Date 2005-12-27 Time 07:25 Rev Time 3.00
Received By alange Date 2005-12-27 Time 07:25 Sent To  
Notes
2005-12-27 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.ALL PLANS SUBMITTED AFTER OCTOBER,
 1, 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 4.SUBMIT TWO COPIES OF ENERGYCALCS TO
 THE 2004 FBC
  
 5. BASED ON SBCCI BUILDING VALUATION
 DATA THE PERMIT VALUE HAS BEEN ADJUSTED
 TO $155,250.ADDITIONAL PERMIT FEES ARE
 DUE.SEE ATTACHED INVOICE.
  
 6.ON PRODUCT APPROVAL FOR TAMKO
 ROOFING, SELECT THE ASSEMBLY THAT WILL
 BE USED.
  
 7.SUBMIT TWO COPIES OF PRODUCT
 APPROVALS FOR STRAPS AND LINTELS.ALL
 PRODUCT APPROVALS SUBMITTED SHALL HAVE
 THE FOLLOWING STATE PRODUCT APPROVAL
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 8.SHOW METHOD OF ROOD DRAINAGE R-801.3
 AND 803.4
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 9 Status P Date 2006-09-30 Cont ID  
Sent By dpalmer Date 2006-09-30 Time 18:55 Rev Time 0.00
Received By dpalmer Date 2006-09-30 Time 18:22 Sent To PC
Notes
2006-09-30 00:00:00REV OK.

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2006-09-08 Cont ID  
Sent By dpalmer Date 2006-09-08 Time 11:28 Rev Time 0.00
Received By dpalmer Date 2006-09-08 Time 11:28 Sent To PC
Notes
2006-09-08 00:00:00LTR ALLOWING THE USE OF #14 FOR 15A
 OCP/ BRKR CIRCUITS, STILL NEEDS TO
 REVISE PANEL SCHEDULE BEFORE FINAL.

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2006-08-25 Cont ID  
Sent By btrobaug Date 2006-08-25 Time 09:10 Rev Time 0.33
Received By btrobaug Date 2006-08-25 Time 09:10 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2006-08-14 Cont ID  
Sent By dpalmer Date 2006-08-14 Time 18:11 Rev Time 0.00
Received By dpalmer Date 2006-08-14 Time 18:02 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status F Date 2006-07-23 Cont ID  
Sent By dpalmer Date 2006-07-23 Time 13:16 Rev Time 0.00
Received By dpalmer Date 2006-07-23 Time 13:14 Sent To M
Notes
2006-07-23 00:00:00****** UNSAT *********
  
 ** IMPORTANT***
  
 WHEN SUBMITTING PLANS, PLEASE BE SURE TO
 SUBMIT TWO COMPLETE SETS FOR REVIEW AND
 STAMPING. THE PLANS WERE SUBMITTED IN
 PEICES OF INDIVIDUAL SHEETS. THESE SETS
 WERE MADE THIS TIME FOR THE REVIEW
 PROCESS. PLEASE KNOW, THIS HELPS IN THE
 REVIEW PROCESS.
  
  
 1) NOTE: PLEASE SEE ALL PLANS REVISING
 ANY PLANS ONRECORD SHALL CONTAIN
 PRINTED NAMES AND SIGNATURES OF ALL
 DESIGN PROFESSSIONALS OF RECORD. PLEASE
 SEE THIS ALSO INCLUDES PLANS WHICH ARE
 NOTE SIGNED, DATED AND SEALED BY THE
 ENGINEER OF RECORD.
  
 FBC 106.1.2, FS 471.025
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-07-14 Cont ID  
Sent By btrobaug Date 2006-07-14 Time 14:56 Rev Time 0.50
Received By btrobaug Date 2006-07-14 Time 14:25 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-01 Cont ID  
Sent By dpalmer Date 2006-03-01 Time 20:25 Rev Time 0.00
Received By dpalmer Date 2006-03-01 Time 20:14 Sent To B
Notes
2006-03-01 00:00:00REDLINED LOAD CALCS, AS COMPRESSOR IS
 STILL SHOWN WITH THE 10KW, LOADS
 WHERE-AS THE LARGEST LOAD IS THE AHU.
 NO CORRECTION NEEDED AT THIS TIME.
 PLEASE CORRECT IF PLANS ARE REVISED
 DURING CONSTRUCTION.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-01-31 Cont ID  
Sent By dpalmer Date 2006-01-31 Time 10:01 Rev Time 0.00
Received By dpalmer Date 2006-01-31 Time 08:07 Sent To M
Notes
2006-01-31 00:00:00********UNSAT *********
  
  
 1)NOTE: PLEASE SEE OCP AND AWG FOR WATER
 HEATER IS SHOWN TOO LARGE. MAX
 150%.422.11E
  
 2)NOTE: PLEASE SEE NO DISCONNECT SHOWN
 ON THE OUTSIDE OF HOUSE AS SHOWN ON
 RISER.
 215.5
  
 3)NOTE: PLEASE SEE MISSING SD IN THE
 IMMEDIATE AREA LEADING TO FLR ABOVE PER
 NFPA-72 11.5.1.1 (FIRST FLR)
  
 4)NOTE: PLEASE SEE LOAD CALCULATIONS
 INDICATE THE COMPRESSOR AS PART OF THE
 LOAD CALCULATIONS, WHEN THE AHU UNIT
 LOAD IS THE LARGER LOAD.
 215.5
  
 5)NOTE: PLEASE SEE NOTES FOR ELECTRICAL
 STILL MENTIONS SD'S TO BE WIRED TO THE
 BATH OR KITCHEN LTS, HOWEVER PLEASE SEE
 BATH IS SHOWN AS A DEDICATED CIRCUIT
 WHICH DOES NOT PERMIT ANY OTHER
 ELECTRICAL ON THAT CIRCUIT. PLEASE ALSO
 SEE NO ARC FAULT PROTECTION IS SHOWN FOT
 KITCHEN LTS AS NOTED ON FIRST REVIEW.
  
  
 PLEASE REMOVE ALL OLD/VOIDED SHEETS AND
 ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-12-12 Cont ID  
Sent By dpalmer Date 2005-12-12 Time 08:48 Rev Time 0.00
Received By dpalmer Date 2005-12-12 Time 08:01 Sent To M
Notes
2005-12-12 00:00:00*********** UNSAT *************
  
  
 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 2)NOTE: PLEASE SEE MISSING RECEPTS
 PER 210.52
  
 3)NOTE: PLEASE SEE MISSING RECEPTS PER
 210.52C3
  
 4)NOTE: COULD NOT LOCATE COND UNIT, TO
 VERIFY DISCONNECTING MEANS. 440.11
  
 5)NOTE: PLEASE SEE PLANS SHOW SD IN
 BATHROOM AND OUTSIDE BATHRM DOOR WITHIN
 3'. PLEASE SEE THIS IS NOT PERMITTED.
 NFPA-72 11.8.3.5
 PLEASE ALSO SEE ONE BEDRM WHERE SD LOOKS
 TO BE JUST OUTSIDE THE DOOR, WHERE
 REQUIRED TO BE LOCATED INSIDE. THESE ARE
 REDLINED ON PLANS FOR CLARIFICATION.
  
 6)NOTE: PLEASE SEE MISSING DEDICATED GDO
 CIRCUIT IN PANELAND IN LOAD CALCS.
 215.5,230.24, 220 ETC .
  
 7)NOTE: PLEASESEE THAT PLANS SPECIFY
 THE CODE WHICH IS IN EFFECT.(2002)
 PLEASE ALSO SEE PLANS CALL FOR ALL TO
 MEET CITY OF RIVERA BEACH? PLEASE SEE
 THIS PROJECT IS LCATED IN THE CITY OF
 WEST PALM BEACH.
 215.5
  
 8)NOTE: PLEASE SEE 424.3B FOR MIN OCP
 FOR AHU 10KW HEAT.
 50A IS NOT LARGE ENOUGH.
  
 9)NOTE: PLEASE SEE 210.52D,210.11C3,
 WHICH REQUIRES ALL BATH CIRCUITS (S) TO
 BE 20A AND #12 AWG. PLEASE SEE 20A OCP
 SHOWN ON #14 AWG ETC.
  
 10)NOTE: PLEASE SEE NOTES ON PLANS
 INDICATE THE SD'S WIRED TO BATH AND
 KITCHEN LIGHTING CIRCUIT. PLEASE SEE
 SD'S ARE ALL REQUIRED TO BE WIRED
 "IN-LINE" (NFPA 72_) AND ARE ALL
 REQUIRED TO BE AFCI PROTECTED AS PER
 210.12 OF THE 2002 NEC.
 PLEASE ADJUST NOTE, UNLESS AFCI BRKRS
 ARE GOING TO BE NOTED FOR KITCHEN LTS
 AND BATH LTS.
 PLEASE CALL TO GO OVER THIS SCENERIO.
  
 11)NOTE: PLEASE SEE 210.11C2 WHICH
 REQUIRES LAUNDRY/WASHER CIRCUITS TO HAVE
 A MIN OF 1.5KW FOR EACH. PLEASE SEE
 PLANS INDICATE LESS VA.
 215.5
  
 12)NOTE: PLEASE SEE LOADS FOR SM APPL,
 TO BE A MIN OF 1500VA.
 210.11C3
  
 13)NOTE: PLEASE SEE MANY OTHER LOADS
 INDICATED ON PANEL SCHEDULE DO NOT SEEM
 TO CORRELATE.
 PLEASE ALSO SEE LIGHTING LOADS ON 15A
 CIRCUITS, SHOWN EXCEED RATING OF
 CIRCUITS.1440 VA 15A. 1920VA 20A.
 215.5
  
  
  
 ** PLEASE REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT NEW REVISED SHEETS INTO
 TWO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 PLEASE SUBMIT ONE COPY OF OLD/VOIDED
 SHEETS FOR REFERENCE.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT ELECTRICAL
 PLANS.
  
 **PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW AND IF THERE ARE ANY
 QUESTIONS, PLEASE DO NOT HESITATE IN
 CONTACTING THIS OFFICE.
  
 **PLEASE SEE MANY OF THE ABOVE ITEMS
 HAVE BEEN REDLNED ON PLANS WHICH ARE
 NOTED.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-02-08 Cont ID  
Sent By adarroug Date 2007-02-08 Time 09:18 Rev Time 0.00
Received By adarroug Date 2007-02-08 Time 09:18 Sent To B
Notes
2007-02-08 09:20:16TO "SHILL" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-01-17 Cont ID  
Sent By adarroug Date 2007-01-17 Time 09:58 Rev Time 0.00
Received By adarroug Date 2007-01-17 Time 09:58 Sent To B
Notes
2007-01-17 09:59:26TO "LMARTINEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-12-28 Cont ID  
Sent By adarroug Date 2006-12-28 Time 11:41 Rev Time 0.00
Received By adarroug Date 2006-12-28 Time 11:41 Sent To B
Notes
2006-12-28 11:42:56TO "LMARTINEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-09-28 Cont ID  
Sent By adarroug Date 2006-09-28 Time 10:18 Rev Time 0.00
Received By adarroug Date 2006-09-28 Time 10:18 Sent To E
Notes
2006-09-28 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-08-28 Cont ID  
Sent By adarroug Date 2006-08-28 Time 11:23 Rev Time 0.00
Received By adarroug Date 2006-08-28 Time 11:23 Sent To E
Notes
2006-08-28 00:00:00TO "DPALMER" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-08-11 Cont ID  
Sent By adarroug Date 2006-08-11 Time 09:05 Rev Time 0.00
Received By adarroug Date 2006-08-11 Time 09:05 Sent To E
Notes
2006-08-11 00:00:00TO "DPALMER' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-07-21 Cont ID  
Sent By adarroug Date 2006-07-21 Time 15:12 Rev Time 0.00
Received By adarroug Date 2006-07-21 Time 15:12 Sent To E
Notes
2006-07-21 00:00:00TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-07-14 Cont ID  
Sent By adarroug Date 2006-07-14 Time 14:01 Rev Time 0.00
Received By adarroug Date 2006-07-14 Time 14:01 Sent To E
Notes
2006-07-14 00:00:00TO "BTROBAUG" DESK/PER "RBROWN"

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-03-01 Cont ID  
Sent By adarroug Date 2006-03-01 Time 08:44 Rev Time 0.00
Received By adarroug Date 2006-03-01 Time 08:44 Sent To E
Notes
2006-03-01 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-28 Cont ID  
Sent By adarroug Date 2006-01-28 Time 15:48 Rev Time 0.00
Received By adarroug Date 2006-01-28 Time 15:48 Sent To E
Notes
2006-01-28 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-01-23 Cont ID  
Sent By adarroug Date 2006-01-23 Time 14:01 Rev Time 0.00
Received By adarroug Date 2006-01-23 Time 14:01 Sent To Z
Notes
2006-01-23 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-10 Cont ID  
Sent By adarroug Date 2005-12-10 Time 10:23 Rev Time 0.00
Received By adarroug Date 2005-12-10 Time 10:23 Sent To E
Notes
2005-12-10 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-27 Cont ID  
Sent By alange Date 2005-12-27 Time 07:34 Rev Time 0.00
Received By alange Date 2005-11-22 Time 15:06 Sent To  
Notes
2005-11-22 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2006-07-26 Cont ID  
Sent By tgordon Date 2006-07-26 Time 08:28 Rev Time 0.15
Received By tgordon Date 2006-07-26 Time 08:28 Sent To P
Notes
2006-07-26 00:00:00MECHANICAL REVISION NOT TO BE REVIEWED
 BY CUSTOMERS REQUEST (MARVELL BORNDS).

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-02-03 Cont ID  
Sent By tgordon Date 2006-02-01 Time 13:30 Rev Time 0.45
Received By tgordon Date 2006-02-03 Time 14:08 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-12-12 Cont ID  
Sent By dpalmer Date 2006-01-31 Time 10:09 Rev Time 0.25
Received By tgordon Date 2005-12-12 Time 14:18 Sent To P
Notes
2005-12-12 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON
 FORM 600A-04 (2004), PER 2004 FBC
 13-600.
 2) NEED TO SHOW THE LOCATION OF THE
 CONDENSER UNIT ON THE PLANS.
 3) NEED TO SHOW DRAIN LINE, OR PUMP ON
 PLANS.
 4) BEDROOM #2 HAS AN 8" SUPPLY AIR DUCT
 AND NEEDS A 10" RETURN TRANSFER DUCT,
 PER 2004 FBC/R M1602.4 .
 5) CLOTHES DRYER EXHAUST NEEDS TO BE
 SHOWING ON PLANS.
 6) IS AHU IN THE CLOSET OR THE ATTIC
 PLEASE SHOW ON PLANS.
 7) NEED TO SHOW THE SIZE OF THE RETURN
 AIR GRILL IN THE 2ND. FLOOR HALLWAY.
 8) PLEASE SHOW COPPER LINE SIZES ON
 PLANS.
 IF YOU HAVE ANY QUESTIOUS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-08-21 Cont ID  
Sent By jleech Date 2006-08-21 Time 09:23 Rev Time 0.00
Received By jleech Date 2006-08-21 Time 09:23 Sent To  
Notes
2006-08-21 00:00:00REVISION;
 ADDED LAUNDRY TUB, DELETED ONE
 LAVATORY. REVISED FLOOR PLAN AND
 SANITARY RISER DIAGRAM TO SHOW CHANGES.

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-08-08 Cont ID  
Sent By jleech Date 2006-08-08 Time 07:12 Rev Time 0.00
Received By jleech Date 2006-08-08 Time 07:12 Sent To B
Notes
2006-08-08 00:00:00DENIED;
 1.SEE ELECTRICAL PLAN REVIEWER'S NOTES.
 2.SECOND FLOOR SHOWER IS NOT VENTED.
 (TOILET FLUSHES PAST SHOWER BEFORE VENT)
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-02-07 Cont ID  
Sent By jleech Date 2006-02-07 Time 15:08 Rev Time 0.33
Received By jleech Date 2006-02-07 Time 15:08 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-12-13 Cont ID  
Sent By tgordon Date 2006-02-03 Time 14:08 Rev Time 0.33
Received By jleech Date 2005-12-13 Time 13:25 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2005-12-15 Cont ID  
Sent By mmclean Date 2005-12-15 Time 08:58 Rev Time 0.00
Received By mmclean Date 2005-12-15 Time 08:58 Sent To B
Notes
2006-01-27 00:00:00PLANS RETURNED TO INCOMING, ALREADY
 APPROVED ON 12/15/05.NO CHANGES.
2005-12-15 00:00:0010FT WIDE DRIVEWAY.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-07 Cont ID  
Sent By mmclean Date 2005-12-07 Time 16:45 Rev Time 0.00
Received By mmclean Date 2005-12-07 Time 16:45 Sent To I
Notes
2005-12-07 00:00:00DENIED,
 1. MUST PROVIDE THE DIMENSION OF
 PROPOSED DRIVEWAY (LENGTH & WIDTH) ON
 TWO COPY OF SURVEY.
 2. MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 NOTE: CAN ONLY HAVE 312.5SQ FT OF
 DRIVEWAY WITHIN THE FIRST 25FT FRONT
 SETBACK (12.5FT)
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720