Plan Review Details - Permit 05110621
Plan Review Stops For Permit 05110621
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-05-04 Cont ID  
Sent By amorse Date 2006-05-04 Time 14:34 Rev Time 0.50
Received By amorse Date 2006-05-04 Time 14:34 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-17 Cont ID  
Sent By amorse Date 2006-03-17 Time 07:58 Rev Time 0.50
Received By amorse Date 2006-03-17 Time 07:58 Sent To PC
Notes
2006-03-17 00:00:00 
  
 DENIED
  
 NO CHANGES WERE MADE TO DRAWINGS FROM
 FIRST REVIEW PLEASE CORRECT THE
 FOLLOWING
  
 1) DRAWINGS TO COMPLY WITH 2004 CODE
 (SEE GENERAL NOTES)
  
 2) UNLESS EXEMPT PER 553.73.10(8)(I)
 (I)CHICKEES CONSTRUCTED BY THE
 MICCOSUKEE TRIBE OF INDIANS OF FLORIDA
 OR THE SEMINOLE TRIBE OF FLORIDA. AS
 USED IN THIS PARAGRAPH, THE TERM
 "CHICKEE" MEANS AN OPEN-SIDED WOODEN HUT
 THAT HAS A THATCHED ROOF OF PALM OR
 PALMETTO OR OTHER TRADITIONAL MATERIALS,
 AND THAT DOES NOT INCORPORATE ANY
 ELECTRICAL, PLUMBING, OR OTHER NONWOOD
 FEATURES.
 NOTE: TRIBE MEMBER TO SUBMIT A COPY OF
 BUREAU OF INDIAN AFFAIRS CARD
  
 3) SHOW THE TIE DOWN AND OR NAILING
 REQUIREMENTS
  
 4) IF PALM FRONDS NOT BEING USED REMOVE
 FROM DRAWINGS
  
 5) SURVEY SHOWS 12X16 SLAB AND CHICKEE
 HUT IS 8X12 PLEASE CLARIFY
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-19 Cont ID  
Sent By amorse Date 2005-12-19 Time 10:29 Rev Time 1.00
Received By amorse Date 2005-12-19 Time 10:29 Sent To PC
Notes
2005-12-19 00:00:00 
  
 DENIED
  
 1) DRAWINGS AND SPECIFICATIONS SHALL
 COMPLY WITH THE 2004 FL BLDG CODE
 EFFECTIVE OCT.1, 2005
  
 2) UNLESS EXEMPT AS PER FLORIDA STATE
 STATUTE 553.73.8(I) THE CHICKEE HUT
 SHALL COMPLY WITH THE FL BLDG CODE
  
 3) SHOW ALL FRAMING COMPONENT TIE DOWNS
 AND NAILING REQUIREMENTS
  
 4) ROOF SETION "B-B" DOES NOT MATCH THE
 ROOF FRAMING DRAWING
  
 5) PALM FRONDS ARE NOT AN APPROVED
 ROFING MATERIAL
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-05-04 Cont ID  
Sent By adarroug Date 2006-05-04 Time 10:40 Rev Time 0.00
Received By adarroug Date 2006-05-04 Time 10:40 Sent To B
Notes
2006-05-04 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-04-17 Cont ID  
Sent By adarroug Date 2006-04-17 Time 10:53 Rev Time 0.00
Received By adarroug Date 2006-04-17 Time 10:53 Sent To Z
Notes
2006-04-17 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-03-16 Cont ID  
Sent By adarroug Date 2006-03-16 Time 16:09 Rev Time 0.00
Received By adarroug Date 2006-03-16 Time 16:09 Sent To B
Notes
2006-03-16 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-03-10 Cont ID  
Sent By adarroug Date 2006-03-10 Time 16:21 Rev Time 0.00
Received By adarroug Date 2006-03-10 Time 16:20 Sent To Z
Notes
2006-03-10 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-05 Cont ID  
Sent By adarroug Date 2005-12-05 Time 11:34 Rev Time 0.00
Received By adarroug Date 2005-12-05 Time 11:34 Sent To B
Notes
2005-12-05 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-10 Cont ID  
Sent By adarroug Date 2005-12-19 Time 16:20 Rev Time 0.00
Received By adarroug Date 2005-11-22 Time 10:41 Sent To  
Notes
2005-11-22 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 4 Status P Date 2006-05-02 Cont ID  
Sent By mmclean Date 2006-05-02 Time 16:52 Rev Time 0.00
Received By mmclean Date 2006-05-02 Time 16:52 Sent To I
Notes
2006-05-02 00:00:00NOTE: THE PROPOSED HUT IN THE REAR IS
 5FT IN THE REAR.

Review Stop Z ZONING
Rev No 3 Status F Date 2006-04-27 Cont ID  
Sent By mmclean Date 2006-04-27 Time 15:44 Rev Time 0.00
Received By mmclean Date 2006-04-27 Time 15:44 Sent To  
Notes
2006-04-27 00:00:00DENIED,
 1. MUST SHOW ON TWO COPY OF SURVEY THE
 REAR SETBACK OF THE HUT FROM PROPERTY
 LINE
 2. SURVEY SHOWS THE DIMENSION, BUT DOES
 NOT SHOW THE REAR SETACK AND SIDE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status F Date 2006-03-14 Cont ID  
Sent By mmclean Date 2006-03-14 Time 12:05 Rev Time 0.00
Received By mmclean Date 2006-03-14 Time 12:05 Sent To I
Notes
2006-03-14 00:00:00DENIED,
 1. HUT MUST BE 5FT IN THE REAR (HUT
 SHOWS 4FT)
 2. HUT MUST MEET THE REAR SETBACK &
 INDICATE ON THE TWO COPY OF SURVEY.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2005-12-02 Cont ID  
Sent By mmclean Date 2005-12-02 Time 13:47 Rev Time 0.00
Received By mmclean Date 2005-11-28 Time 07:06 Sent To I
Notes
2005-12-02 00:00:0012/2/05 REVIEWED & FAILED BY SHIRLEY
 GRAHAM, ASSOCIATE PLANNER 822-1435 MM
2005-11-28 00:00:00DENIED HUT MUST BE 5' FROM THE REAR


Account Summary | Usage Policy | Privacy Policy