Plan Review Details - Permit 05110617
Plan Review Stops For Permit 05110617
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-10-24 Cont ID  
Sent By amorse Date 2006-10-24 Time 11:02 Rev Time 0.00
Received By amorse Date 2006-10-24 Time 11:02 Sent To  
Notes
2006-10-24 11:15:33 
  
 DENIED
  
 1) PLEASE SEE THAT THE LICENCE # THAT IS NOW ON THE
 DRAWINGS (F95000002990) IS NOT A CERTIFICATE OF
 AUTHORIZATION NUMBER BUT A STATE OF FLORIDA
 OCCUPATIONAL LICENCE NUMBER. ACCORDING TO THE STATE
 WEBSITE FOR THE DEPT OF BUSINESS AND PROFESSIONAL
 REGULATION YOUR APPLICATION FOR A CA# IS STILL IN
 PROGRESS.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-06-19 Cont ID  
Sent By amorse Date 2006-06-19 Time 14:50 Rev Time 0.00
Received By amorse Date 2006-06-19 Time 14:50 Sent To  
Notes
2006-06-19 00:00:00 
  
 DENIED
  
 NOTE #3 ON FIRST REVIEW NOT ADDRESSED:
  
 1) THE STATE HAS YOUR APPLICATION FOR A
 CA# IN PROGRESS, A PERMIT CANNOT BE
 ISSUED UNTILL LICENCING REQUIREMENTS ARE
 MET. PLEASE BE AWARE THAT LICENCE THAT
 HAS BEEN APPLIED FOR IS UNDER
 WD PARTNERS INC. AND TITLE BLOCK
 INFORMATION SHOULD MATCH THIS. (THEIR IS
 NO INC. IN TITLE BLOCK AT THIS TIME)
  
 NOTE #4 ON FIRST REVIEW NOT ADDRESSED:
  
 2) EQUIPMENT STANDS ON THE ROOF ARE
 COVERED BY 9B-72 OF THE FLORIDA
 ADMINISRATIVE CODE AND AS SUCH REQUIRE
 STATE OF FLORIDA PRODUCT APPROVAL
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-03-01 Cont ID  
Sent By amorse Date 2006-03-01 Time 09:08 Rev Time 0.00
Received By amorse Date 2006-03-01 Time 09:08 Sent To PC
Notes
2006-03-01 00:00:00 
  
 DENIED
  
 1) A TITLE BLOCK WITH THE INFORMATION
 SPECIFIED PER 61G1-16.004 FAC SHALL BE
 PRESENT ON DRAWINGS ISSUED BY THE
 RESPONSIBLE ARCHITECT AND MUST, AT A
 MINIMUM CONTAIN
 1)FIRM NAME,ADDRESS, AND TELEPHONE #
 2)FIRM LICENCE #
 3)NAME OF PROJECT
 4)DATE PREPARED
 5)A SPACE FOR SIGNATURE & DATED SEAL
 6)A SPACE FOR PRINTED NAME OF PERSON
 SEALING THE DOCUMENT
  
 2) MAKE CHANGES TO PAGE G.0.1 TO REFLECT
 FBC 2004 AND BUILDING DISCRIPTION
  
 3) AN ENGINEER PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS SHALL
 INDICATE THEIR NAME AND LICENCE #, AS
 WELL AS THE NAME,ADDRESS AND CERTIFICATE
 OF AUTHORIZATION #ON EACH SHEET PER
 61G15-23.002 (1)- (5). PLEASE SEE THAT
 THE CA # YOU HOLD IN THE STATE OF
 FLORIDA IS UNDER WOLFGANG DOERSCHLAG
 ARCHITECTS LTD., INC AND NOT WD PARTNERS
  
 4) EQUIPMENT THAT IS TO BE PLACED ON
 ROOF, INDICATE IF IT IS REPLACEMENT OR
 NEW AND IF NEW CONFIRM THAT ROOF IS
 DESIGNED FOR ADDED LOADS. ALSO WILL
 INSTALLATION OF EQUIPMENT REQUIRE ROOF
 MEMBRANE WORK AND A ROOF PERMIT.
 EQUIPMENT STANDS WILL REQUIRE PRODUCT
 APPROVALS PER 9B-72 FAC
  
 5) 8X10 STORAGE SHED ON SHEET 1 WILL
 REQUIRE A SEPARATE PERMIT WITH 2 COPIES
 OF SURVEY SHOWING SETBACKS TO SHED. IF
 SHED IS BUILT BY A STATE OF FLORIDA
 APPROVED MODULAR BUILDING MANUFACTURER
 ALSO SUBMIT THE PRODUCT APPROVALS, IF
 BUILT ON SITE DRAWINGS WILL BE REQUIRED
 THAT WILL MEET THE WIND LOADS OF 1609
 FBC 2004. WEST PALM BEACH IS 140 MPH 3
 SECOND GUST, EXP. B, IMPORTACE FACTOR 1
  
 6) FOOD AND BEVERAGE COUNTERS SHALL MEET
 THE REQUIREMENTS OF 11-5.2 OF THE
 FLORIDA ACCESSABILITY CODE FBC 2004
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-10-25 Cont ID  
Sent By dpalmer Date 2006-10-25 Time 07:29 Rev Time 0.00
Received By dpalmer Date 2006-10-25 Time 07:23 Sent To  
Notes
2006-10-25 07:44:37****** UNSAT 3RD REVIEW *******
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ALONG
 WIHT NEW NOTE DUE TO CHNAGE IN PLAN.
  
 1) NOTE: PLEASE SEE TWO PREVIOUS REVIEW WHICH GAVE
 FLORIDA ADMINISTRATIVE CODE61G15-23.002 AND FLORIDA
 STATUTES 471.023/481.219. PLEASE KNOW THAT THE NUMBER
 WHICH HAS NOW BEEN ADDED TO TITLE BLOCKS FOR REQUIRED
 "CERTIFICATE OF AUTHORIZATION" NUMBER OR "FIRM LICENSE"
 NUMBER IS NOT THAT OF WHICH IS THE REGISTRATION NUMBER
 AS LISTED ON TITTLE BLOCKS WHICH IS THE FLORIDA
 OCCUPATIONAL LICENSE NUMBER DOING BUSINESS IN THE STATE
 OF FLORIDA.
 THE NUMBER AS SHOWN IS THE OCC LICENSE WHICH CAN BE
 FOUND ONE WWW.SUNBIZ.ORG. PLEASE CONTACT THE FLORIDA
 DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION AT
 THEIR SITE WHICH ALSO CONTAINS INFORMATION ON HOW TO
 CONTACT THEM. (WWW.STATE.FL.US/DBPR) PLEASE ALSO
 CONTACT THE FLORIDA BOARD OF PROFESSIONAL ENGINEERS AS
 THEY ALSO MAY BE OF SOME ASSISTANCE AT WWW.FBPE.ORG..
 PLEASE SEE AS STATED ON PREVIOUS REVIEWS IF THERE ARE
 ANY QUESTIONS, PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE AS PREVIOUSLY NOTED.
  
 2) NOTE: PLEASE SEE THE EM/EXT LTS ARE SHOWN BEING
 SHOWN HOWEVER PLEASE SEE 700.12E WHICHREQUIRES THE
 BRANCH CIRCUIT FEEDING THE UNIT EQUIPMENT SHALL BE THE
 SAME BRANCH CIRCUIT AS THAT SERVING THE NORMAL LIGHTING
 IN THE AREA AND CONNECTED AHEAD OF ANY LOCAL SWITCHES.
  
  
 ** PLEASE KNOW WITH RESPECT TO THE EXISTING MDP, THIS
 WILL BE VERIFIED IN FEILD AND REDLINED ON PLANS.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-10 Cont ID  
Sent By dpalmer Date 2006-06-10 Time 12:35 Rev Time 0.00
Received By dpalmer Date 2006-06-10 Time 12:02 Sent To  
Notes
2006-06-10 00:00:00******** UNSAT ********
  
 ** PLEASE SEE NOTES FROM FIRST REVIEW
 STILL NEED TO BE ADDRESSED.
 ** PLEASE SEE NOTE BELOW EACH NOTE WHICH
 IS NOTED AS "**PREVIOUS NOTE**" IS TAKEN
 DIRECTLY FROM PREVIOUS REVIEW.
  
 CODE REFERENCES WERE CORRECTED.
  
 **
  
 1)NOTE: NOTE #1 NO, PLEASE SEE NOTE FROM
 PREVIOUS REVIEW HAS STILL NOT BEEN
 ADDRESSED.
 PLEASE SEE THE PRINTED NAME AND LICENSE
 NUMBER OF EACH DESIGNER IS ONLY PART OF
 WHAT IS REQUIRED AND WHAT WAS NOTED ON
 PREVIOUS REVIEW. PLEASE SEE THE FLORIDA
 STATUES AS REFERENCED 481.219,471.023
 REQUIRES ANY FIRM PROVIDING
 ARCHITECTURAL OR ENGINEERING SERVICES
 SHALL OBTAIN CERTIFICATE OF
 AUTHORIZATION NUMBER(S) AND SAID NUMBERS
 FOR EACH SERVICE BEING PROVIDED. PLEASE
 SEE THAT EACH OF THESE SAID NUMBERS
 SHALL BE ON ALL TITLE BLOCKS ON PLANS
 AND ON ALL SHEETS CONTAIN TITLE BLOCKS
 FOR FIRMS AS REQUIRED BY THE FLORIDA
 ADMINISTRATIVE CODE 61G15-23.002,
 61G1-16.004
  
 ** PREVIOUS NOTE **
 PLEASE SEE FLORIDA ADMINISTRATIVE CODE
 61G15-23.002 AND 61G1-16.004 FOR MISSING
 REQUIRED INFORMATION FOR TITLE BLOCKS
 INCLUDING LICENSING INFORMATION AS
 REUIRED UNDER FS 471.023 AND FS 481.219.
 ** PLEASE KNOW THIS IS REQUIRED FOR ALL
 TRADES AND FOR ALL SHEETS WHETHER OR NOT
 COMMENT IS MADE BY OTHER REVIEWER(S).
  
 2)NOTE:OK, SHEET REMOVED.
  
 3)NOTE:NOTE #3 NO, PLEASE SEE THAT A
 MCB WILL BE REQUIRED AS THE PANEL AS
 SHOWN DOES NOT MEET NEC REQUIREMENTS FOR
 THE SERVICE EQUIPMENT NOT TO CONTAIN ANY
 MORE THAN 6 SPACES OR 6 MEANS OF
 DISCONNECT. PLEASE SEE EQUIPMENT AS
 SHOWN IS CAPABLE OF CONTAINING MANY MORE
 THAN 6.
 EVEN THOUGH THIS MAY BE AN EXISTING
 CONDITION, WITH THE WORK BEING PERMITTED
 THIS WILL BE REQUIRED, NO EXCEPTIONS.
  
 ** PREVIOUS NOTE**
 PLEASE SEE EXISTING MAIN IS
 SHOWN AS MLO, AND SHOWING MANY MORE THAN
 THE SIX SPACES (MAX) ALLOWED BY NEC,
 230.70.
 PLEASE VERIFY THAT IF A MCB IS NOT
 PRESENT,
 IF NOT A MCB WILL BE REQUIRED TO BE
 INSTALLED FOR CODE COMPLIANCE.
  
 4)NOTE: NOTE #4 NO, COULD ONLY LOCATE
 SOME OF THESE RECEPTS BEING PROTECTED.
  
 ** PREVIOUS NOTE **
 PLEASE SEE 2002 NEC 210.8B3
 WHICH REQUIRES ALL 15- AND 20-AMPERE,
 125-VOLT RECEPTACLES IN NONDWELLING-TYPE
 KITCHENS TO BE GFCI PROTECTED. THIS
 REQUIREMENT APPLIES TO EACH AND EVERY
 15- AND 20-AMPERE, 125-VOLT KITCHEN
 RECEPTACLE, WHETHER OR NOT THE
 RECEPTACLE SERVES COUNTERTOP APPLIANCES.
  
 5)NOTE: NOTE #5 NO, PLEASE SEE PREVIOUS
 COMMENTS FROM FIRE REVIEW AND ELECTRICAL
 WERE TO SHOW EITHER THE NEW OR EXISTING
 LOCATIONS OF THE EM/ EXT LTS.
 PLEASE SEE A NOTE ADDED TO PLANS WHICH
 MENTIONS FOR THE "CONTRACTOR TO VERIFY".
 PLEASE SEE THIS DOES NOT SHOW THE
 CONDITIONS AS REQUESTED ON PREVIOUS
 COMMENT. PLEASE SHOW NEW OR EXIST
 LOCATIONS.
  
 ** PREVIOUS NOTE **
 PLEASE PROVIDE THE NEW AND/OR
 EXISTING EMERGENCY AND EXT LT LOCATIONS
 ON ELECTRICAL PLANS TO VERIFY NFPA-101
 7.8, 7.9
 PLEASE ALSO SEE FIRE REVIEW COMMENTS.
  
  
 ** NEW NOTE **
  
 6) NOTE: PLEASE SEE COPY OF THE FLORIDA
 STATUE 553.80(2)(B) IS ATTACHED WITH
 REPSECT TO DESIGN PREOFESSIONAL AND
 REPEAT COMMENTS FOR PLAN REVIEW.
 PLEASE KNOW, THIS IS ONLY A NOTE GIVE AT
 THIS TIME.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-12-24 Cont ID  
Sent By dpalmer Date 2005-12-24 Time 10:39 Rev Time 0.00
Received By dpalmer Date 2005-12-24 Time 09:40 Sent To  
Notes
2005-12-24 00:00:00************** UNSAT *************
  
  
 ****************************************
 PLEASE SEE THE WRONG CODES REFERENCED ON
 THE COVER SHEETS AND DESIGNS.
 PLEASE SEE WE ARE CURRENTLY UNDER THE
 2004 FBC. PLEASE SEE ANY CHANGES DUE TO
 NEW REQUIREMENTS FOR EXSITING BUILDINGS.
 PLEASE ADJUST AS NEEDED.
 THIS IS REQUIRED FOR ALL TRADES AND FOR
 ALL SHEETS.
 THE NEC IN EFFECT IS THE 2002.
  
 1)NOTE: PLEASE SEE FLORIDA
 ADMINISTRATIVE CODE 61G15-23.002 AND
 61G1-16.004 FOR MISSING REQUIRED
 INFORMATION FOR TITLE BLOCKS INCLUDING
 LICENSING INFORMATION AS REUIRED UNDER
 FS 471.023 AND FS 481.219.
 ** PLEASE KNOW THIS IS REQUIRED FOR ALL
 TRADES AND FOR ALL SHEETS WHETHER OR NOT
 COMMENT IS MADE BY OTHER REVIEWER(S).
  
 2)NOTE: PLEASE SEE ZONING COMMENTS WITH
 RESPECT TO THE LAST SHEET IN EACH SET.
 PLEASE SEE THAT ALL SIGNAGE WILL BE
 REQUIRED TO BE UNDER SEPARATE PERMITS.
 PLEASE REMOVE THIS SHEETS FROM SETS.
 ** PLEASE KNOW, THIS SHEETS IS ALSO A
 SEALED PHOTOCPOY OF THE ENGINEER'S
 ORIGINAL SIGNATURE. PLEASE BE SURE
 SUBMIT THE CORRECTED SHEETS AS FS
 471.025 FAC 61G15-23.002 REQUIRES THE
 ORIGINAL "WET" SIGNATURE AND DATE.
  
 3)NOTE: PLEASE SEE EXISTING MAIN IS
 SHOWN AS MLO, AND SHOWING MANY MORE THAN
 THE SIX SPACES (MAX) ALOOWED BY NEC,
 230.70.
 PLEASE VERIFY THAT A MCB IS NOT PRESENT,
 IF NOT A MCB WILL BE REQUIRED TO BE
 INSTALLED FOR CODE COMPLIANCE.
  
 4)NOTE: PLEASE SEE 2002 NEC 210.8B3
 WHICH REQUIRES ALL 15- AND 20-AMPERE,
 125-VOLT RECEPTACLES IN NONDWELLING-TYPE
 KITCHENS TO BE GFCI PROTECTED. THIS
 REQUIREMENT APPLIES TO EACH AND EVERY
 15- AND 20-AMPERE, 125-VOLT KITCHEN
 RECEPTACLE, WHETHER OR NOT THE
 RECEPTACLE SERVES COUNTERTOP APPLIANCES.
  
 5)NOTE: PLEASE PROVIDE THE NEW AND/OR
 EXISTING EMERGENCY AND EXT LT LOCATIONS
 ON ELECTRICAL PLANS TO VERIFY NFPA-101
 7.8, 7.9
 PLEASE ALSO SEE FIRE REVIEW COMMENTS.
  
 ** PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2006-12-18 Cont ID  
Sent By mawillia Date 2006-12-18 Time 12:23 Rev Time 0.00
Received By mawillia Date 2006-12-18 Time 12:22 Sent To  
Notes
2006-12-18 12:28:22*****PROVISO*****
  
  
  
  
  
 1.SHOW THE LOCATION OF THE FIRE EXTINGUISHERS.ONE
 NEEDED IN THE SALES AREA AND THE OTHER IN THE BACK
 AREA.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-06-23 Cont ID  
Sent By mwennerg Date 2006-06-23 Time 11:00 Rev Time 0.00
Received By mwennerg Date 2006-06-23 Time 11:00 Sent To  
Notes
2006-06-23 00:00:00***DENIED***
  
 1) 2A-10B,C RATED FIRE EXTINGUISHER(S)
 ARE REQUIRED.
  
 2) PLEASE CLEARLY IDENTIFY THE LOCATIONS
 OF EXIT LIGHTS AND EMERGENCY LIGHTING
 FACILITIES. PLANS INDICATE (2) EXIT HAVE
 BEEN PROVIDED. PLEASE SHOW ALL LOCATIONS
 OF EMERGENCY LIGHTING. IT APPEARS THAT
 ONLY (1) EXIT SIGN IS ILLUSTRATED ON
 LIGHTING FLOOR PLAN.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-12-18 Cont ID  
Sent By mcarsill Date 2005-12-06 Time 12:28 Rev Time 0.00
Received By mawillia Date 2005-12-14 Time 17:50 Sent To  
Notes
2005-12-06 00:00:001. BUILDING ADDRESS IS REQUIRED. A
 MINIMUM OF AT LEAST 6" HIGH NUMBERS ARE
 REQUIRED.
  
 2. NO EMERGENCY LIGHTING EQUIPMENT SHOWN
 ON ELECTRICAL DRAWINGS.
  
 3. SEPERATE PLANS AND PERMITS REQUIRED
 FOR THE PROPOSED HOOD, DUCT, AND
 SUPPRESSION SYSTEMS.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER
 804-4709

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-10-10 Cont ID  
Sent By adarroug Date 2006-10-10 Time 12:53 Rev Time 0.00
Received By adarroug Date 2006-10-10 Time 12:53 Sent To  
Notes
2006-10-24 09:36:49TO "COMM" BD#11
2006-10-10 12:54:06WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-23 Cont ID  
Sent By adarroug Date 2006-05-23 Time 10:42 Rev Time 0.00
Received By adarroug Date 2006-05-23 Time 10:42 Sent To  
Notes
2006-06-02 00:00:00TO "COMM" BD#26
2006-05-23 00:00:00WAITING FOR "COMM" BD-NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-03-01 Cont ID  
Sent By amorse Date 2006-03-01 Time 09:08 Rev Time 0.00
Received By amorse Date 2005-11-21 Time 16:19 Sent To  
Notes
2005-12-02 00:00:00TO "COMM" BD#51
2005-11-21 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-10-30 Cont ID  
Sent By pkrauss Date 2006-10-30 Time 07:11 Rev Time 0.00
Received By pkrauss Date 2006-10-30 Time 07:11 Sent To  
Notes
2006-10-30 07:34:18DENIED:
 COMMENT 1 FROM PREVIOUS REVIEW WAS NOT ADDRESSED,
 CERTIFICATE OF AUTHORIZATION IS NOT A VALID NUMBER.
 PLEASE ALSO NOTE, THE SEAL IS NOT LEGIBLE ON PLAN SHEET
 SF05 M.1.0.
  
 THE FOLLOWING INFORMATION IS REQUIRED FOR THE ISSUANCE
 OF THE HOOD PERMIT.
 PLEASE PROVIDE A DETAIL FOR THE HANGING OF THE HOOD.
 PLEASE PROVIDE THE FOLLOWING INFORMATION:
 A) ATTACHMENT TO THE CEILING TRUSSES
 B) SIZE OF RODS
 C) VIBRATION ISOLATION
 D) MATERIAL OF EXHAUST DUCT
 E) TYPE II HOODS SHALL COMPLY WITH 2004 FMC 507.1 AND
 507.4.
  
 PLANS ARE OTHERWISE CODE COMPLIANT.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS
 AT (561)805-6719 OR E-MAIL [email protected].

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-07-05 Cont ID  
Sent By pkrauss Date 2006-07-05 Time 06:49 Rev Time 0.00
Received By pkrauss Date 2006-07-05 Time 06:43 Sent To  
Notes
2006-07-05 00:00:00DENIED:
 1.PLEASE SEE COMMENTS BY ELECTRICAL &
 BUILDING PLANS EXAMINER WITH REGARDS TO
 TO CERTIFICATE OF AUTHORIZATION FOR THE
 ENGINEERING/ARCHITECTURAL FIRM.
  
 2.PLEASE PROVIDE FLORIDA PRODUCT
 APPROVAL FOR THE CONDENSING UNIT STAND
 INDICATED ON PLAN SHEET SF05 Q.1.1.
  
 PLEASE NOTE, ADDITIONAL PERMIT REQUIRED
 FOR WALK-IN COOLER/FREEZER.PLEASE
 PROVIDE MANUFACTURE SUBMITTAL SHEETS
 WITH PERMIT APPLICATION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561)805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-12-14 Cont ID  
Sent By rregueir Date 2005-12-14 Time 17:51 Rev Time 0.00
Received By rregueir Date 2005-12-14 Time 17:51 Sent To  
Notes
2005-12-14 00:00:00-------------------DENIED---------------
  
 1) IF HOOD FAN IS WITHIN 10' OF ROOF
 EDGE A GUARD IS REQUIRED PER FBC,M
 304.10
  
 2)PAGE E.1.0 KEYED NOTE #8 CALLS FOR
 CONDENSERS TO BE MOUNTED ON ROOF.ARE
 THESE NEW OR BEING RELOCATED?PROVIDE
 DETAIL FOR ROOFTOP INSTALLATION OF
 EQUIPMENT WITH ENGINEERING FOR STANDS TO
 SHOW COMPLIANCE WITH WIND LOAD AND ROOF
 CLEARANCE REQUIREMENTS OF FBC 1509.7
  
 3) EQUIPMWNT ON ROOF REQUIRING SERVICE
 NEEDS PERMENANT ACCESS PER FBC,M 306.5
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 RON REGUEIRO @ 561.805.6734 OR PATTY
 KRAUSS @ 561.805.6719

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-10-28 Cont ID  
Sent By pschmitz Date 2006-10-28 Time 09:24 Rev Time 0.00
Received By pschmitz Date 2006-10-28 Time 09:23 Sent To  
Notes
2006-10-28 09:24:45PLUMBING PLAN REVIEW EXAMINER
 PAUL SCHMITZ 561-805-6692
 [email protected]
 FBC PLUMBING 2004
 FBC FUEL GAS 2004
 AMENDMENTS TO THE FLORIDA BUILDING CODE
 CH 1, ADMINISTRATION, 2004 EDITION
 (ATFBC) FBC BUILDING 2004, CH 11
  
 UNSAT
 PREVIOUS NOTES NOT ADDRESSED FROM OTHER
 PLAN REVIEWERS.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT PLUMBING
 PLANS.
  
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-07-02 Cont ID  
Sent By pschmitz Date 2006-07-02 Time 05:58 Rev Time 0.00
Received By pschmitz Date 2006-07-02 Time 05:57 Sent To  
Notes
2006-07-02 00:00:00PLUMBING PLAN REVIEW EXAMINER
 PAUL SCHMITZ 561-805-6692
 [email protected]
 FBC PLUMBING 2004
 FBC FUEL GAS 2004
 AMENDMENTS TO THE FLORIDA BUILDING CODE
 CH 1, ADMINISTRATION, 2004 EDITION
 (ATFBC) FBC BUILDING 2004, CH 11
  
 UNSAT
 PREVIOUS NOTES NOT ADDRESSED FROM OTHER
 PLAN REVIEWERS.
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT PLUMBING
 PLANS.
  
 END OF COMMENTS, QUESTIONS 561-805-6692

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-03-01 Cont ID  
Sent By pschmitz Date 2006-03-01 Time 11:06 Rev Time 0.00
Received By pschmitz Date 2006-02-25 Time 07:14 Sent To  
Notes
2006-02-25 00:00:00PLUMBING PLAN REVIEW EXAMINER
 PAUL SCHMITZ 561-805-6692
 [email protected]
 FBC PLUMBING 2004
 FBC FUEL GAS 2004
 AMENDMENTS TO THE FLORIDA BUILDING CODE
 CH 1, ADMINISTRATION, 2004 EDITION (
 ATFBC) FBC BUILDING 2004, CH 11
 PROVISO:
  
 PLEASE SEE ANY POSSIBLE COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT PLUMBING
 PLANS.
  
 END OF COMMENTS, QUESTIONS 561-805-6692
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2006-11-02 Cont ID  
Sent By jroach Date 2006-11-02 Time 08:52 Rev Time 0.00
Received By jroach Date 2006-11-02 Time 08:52 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-07-02 Cont ID  
Sent By jroach Date 2006-07-02 Time 14:40 Rev Time 0.00
Received By jroach Date 2006-07-02 Time 14:40 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2006-01-25 Cont ID  
Sent By jroach Date 2006-01-25 Time 14:30 Rev Time 0.00
Received By jroach Date 2006-01-25 Time 14:30 Sent To  
Notes
2006-01-25 00:00:001/25/06 ***FAILED***
  
 NO OBJECTIONS TO THE INTERIOR
 REMODELING, HOWEVER, EXTERIOR SIGNAGE
 SHALL BE APPLIED FOR UNDER SEPARATE
 PERMITS.REMOVE THEM FROM THIS PERMIT
 APPLICATION.SIGNS WILL BE REVIEWED
 UPON SUBMITTAL OF NEW APPLICATION.FOR
 REFERENCE, POSTERS ON THE EXTERIOR SHALL
 NOT BE PERMITTED.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH,
 PLANNER AT (561) 822-1435.