| Plan Review Stops For Permit 05110490 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-04-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-05 |
Time |
11:02 |
Rev Time |
1.66 |
| Received By |
alange |
Date |
2006-04-05 |
Time |
10:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-23 |
Time |
10:28 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-03-23 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2006-03-23 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | | | | 6.PRODUCT APPROVAL REQUIRED FOR | | | LINTELS WITH THE FOLLOWING STATE PRODUCT | | | APPROVAL. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-07 |
Time |
10:30 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-02-07 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2006-02-07 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. CHECK ALL | | | REFERENCES AND CONSTRUCTION TYPE. | | | | | | | | | 6.PRODUCT APPROVAL REQUIRED FOR | | | LINTELS WITH THE FOLLOWING STATE PRODUCT | | | APPROVAL. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-27 |
Time |
09:50 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2005-12-27 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2005-12-27 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 4.ENERGY CALCS. SHALL BE SUBMITTED | | | ACCORDING TO THE 2004 FBC. | | | | | | 5."R" VALUES ON PLANS DO NOT MATCH | | | ENERGY CALCS. | | | | | | 6.PRODUCT APPROVAL REQUIRED FOR | | | LINTELS WITH THE FOLLOWING STATE PRODUCT | | | APPROVAL. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-06-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-21 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-21 |
Time |
10:25 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-06-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-03 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-03 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
| 2007-06-03 16:28:33 | ** UNSAT ** | | | | | | | | | 1) NOTE: PLEASE SEE MISSING DISCONNECT FOR MASTER | | | BEDROOM WATER HEATER.422.31 THE SYMBOL AS SHOWN ON | | | PLANS IS FOR A RECEPTACLE. | | | | | | 2) NOTE: PLEASE SEE PANEL SCHEDULES WHICH INDICATE TWO | | | AHU'S #2. PLEASE SEE PANEL *B* WHICH INDICATE 10KW AHU | | | WITH 30AMP OCP AND #8 CONDUCTORS WHICH ARE NOT OF | | | SUFFICIENT SIZE PER 240.4, 424.3B, AND 310.16. | | | PLEASE ADJUST. | | | | | | 4) NOTE: PLEASE SEE PANEL SCHEDULES STILL INDICATE 40 | | | CIRCUITS( MISPRINT). | | | PLEASE ADJUST. | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE PROVIDE THE GROUNDING ATTACHMENT FOR | | | THE DETACHED GARAGE AS REQUIRED PER 250.32. THIS WAS | | | ISSUED WITH NOTE ON PLAN TO COMPLY, HOWEVER THE | | | ATTACHMENT SHOULD BE KNOWN AND SHOWN ON PLANS. | | | | | | 6) NOTE: PLEASE SEE PLANS AND PANEL SCHEDULE INDICATE | | | SMOKE DEVICES AS *SD* AND SYMBOL LEGEND HAS THESE AS | | | SMOKE DETECTORS. | | | PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN | | | SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY | | | INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS | | | ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN | | | THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS | | | OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE | | | ALARMS. | | | THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE | | | OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. BY | | | THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | | FOR OTHER NEW HOMES. | | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE*. | | | PLEASE SEE NFPA-72 11.5.1.1, 11.8.3 | | | | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-10 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-10 |
Time |
17:45 |
Sent To |
E |
|
| Notes |
| 2006-03-10 00:00:00 | ******* PROVISO ** 3RD REVIEW ******** | | | | | | 1)NOTE: PLEASE SEE LOAD SHOWN ON PANEL | | | "A"FOR PANEL "C" DOES NOT CORRELATE | | | WITH ACTUAL LOAD INDICATED ON PANEL "C", | | | PLEASE ADJUST. | | | | | | 2)NOTE: PLEASE SEE RISER INDICATES 40 | | | CIRCUIT PANELS, AND PANEL SCHEDULES | | | INDICATE THESE AS 42 CIRCUIT PANELS. | | | | | | 3)NOTE: PLEASE SEE THE NEW ADDED PANEL | | | "D" NOW ALSO INDICATES A NEW GAS POOL | | | HEATER?? . PLEASE SEE PANEL "C" ALREADY | | | INDICATES ONE GAS POOL HEATER. PLEASE | | | ALSO SEE PLANS DO NOT INDICATE TWO GAS | | | POOL HEATERS? | | | PLEASE CORRELATE. | | | | | | ** PLEASE REVISE AND SUBMIT THE ABOVE | | | INFORMATION FOR REVIEW ALONG WITH ANY | | | OTHER REVISIONS BEFORE "ROUGH" | | | ELECTRICAL INSPECTION. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION , IF | | | THERE ARE ANY QUESTIONS, PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-30 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-30 |
Time |
17:36 |
Sent To |
M |
|
| Notes |
| 2006-01-30 00:00:00 | ******** UNSAT2ND REVIEW ********** | | | | | | PLEASE SEE SOME EXISTING NOTES AND SOME | | | NEW NOTES. | | | | | | | | | | | | 1)NOTE: OK | | | | | | 2)NOTE: OK | | | | | | 3)NOTE: OK, HOWEVER PLEASE NOW SEE POOL | | | HEATER IS BEING SHOWN AS GAS, YET SHOWS | | | 4KW LOAD AND SHOWS BEING CONTINUOUS?? | | | PREVIOUS PLANS CALLED FOR AN ELEC HEAT | | | PUMP. | | | | | | ** PLEASE INDICATE ALL CONTINUOUS | | | LOADS ON POOL PANEL AT 125%. | | | PLEASE ALSO SEE THIS WILL CHANGE LOAD | | | AND EXCEED RATING OF OCP AND FEEDERS TO | | | POOL PANEL. PLEASE ADJUST AS NEW OCP AND | | | FEEDERS WILL NEED TO BE INCREASED. | | | 215.5,230.42,215..3,90.8 | | | | | | 4)NOTE: OK | | | | | | 5)NOTE: OK | | | | | | 6)NOTE: OK | | | | | | 7)NOTE: OK, HOWEVER PLEASE SEE | | | DISCONNECTING NOTE FOR DETACHED GARAGE. | | | | | | 8)NOTE: OK | | | | | | 9)NOTE: OK | | | | | | 10)NOTE: OK, NOTED. | | | | | | 11)NOTE:OK/ NO, PLEASE SEE DISCONNECT | | | SWITCH(S) SHOULD BE SHOWN FOR GDO NOW | | | ADDED. | | | PLEASE SEE NOTE ADDED FOR GROUNDING, | | | SHOULD REFERENCE 250.32, HOWS 225.31 | | | WHICH IS THE DISCONNECT REQUIREMENT. | | | PLEASE SEE 250.32 WHICH REQUIRES A | | | GROUNDING ELECTRODE TO FOOTER STEEL MIN | | | . | | | | | | **PLEASE SEE THE DETACHED GARAGE | | | WOULD REQUIRE MEANS OF DISCONNECT AS | | | REQUIRED UNDER 225.31-225.36. | | | PLEASE SEE DISCONNECTING MEANS MAY BE A | | | TOGGLE SWITCH TYPE DEVICE IF MEETING THE | | | EXCEPTIONS. | | | | | | 12)NOTE: OK | | | | | | 13)NOTE: NO, PLEASE SEE PANEL "A" SHOWS | | | A 5KW HEAT, LOAD CALCULATIONS INDICATE | | | 65% AS 6500W?? | | | PLEASE ALSO SEE PANEL "B" SHOWS TWO | | | UNITS AS 10KW, HOWEVER 65% ON LOAD | | | CALCUALTIONS INDICATES 9750W?? | | | PLEASE SEE 655 OF 20KW ,, | | | PLEASE CORRELATE ALL KW LOADS | | | FOR AHU'S WITH KW RAITNGS SHOWN ON | | | MECHANICAL PLANS. PLEASE MAKE ANY | | | ADJUSTMENTS NEEDED FOR OCP, AWG, LOAD | | | CALCS ETC. | | | 215.5 | | | | | | NEW NOTES: | | | | | | 1)NOTE: PLEASE SEE POOL PANEL IS SHOWN | | | ON PLANS BEING FED FROM WHAT APPEARS TO | | | BE THE INSIDE PANEL "B", YET RISER SHOWS | | | THIS COMING FROM THE OUTSIDE MCB PANEL. | | | ?? | | | ** PLEASE CORRELATE RISER AND PANELS AS | | | PANEL SCHEDULES SHOWN INDICATE THESE AS | | | MCB PANELS WHICH ARE 40 CIRCUIT PANELS, | | | YET RISER SHOWS THE MCB PANELS AS 8-16? | | | PLEASE ALSO SEE RISER AS THESE PANELS DO | | | NOT SEEM TO CORRELATE. | | | ** PLEASE PROVIDE PANEL SCHEDULES FOR | | | OUTDOOR MCB PANELS IF THERE ARE CIRCUITS | | | COMING FROM THESE PANELS AS SHOWN. | | | ** PLEASE SEE 230.7, SERVICE ENTRANCE | | | CONDUCTORS MAY NOT BE IN THE SAME | | | RACEWAY/ENCLOSURE WITH THE | | | BRANCHCIRCUITS OR FEEDERS. | | | PLEASE REVISE RISER DIAGRAM AS MCB PANEL | | | "B" MAY NOT BED FED THORUGH MCB PANEL | | | "A". | | | | | | 2)NOTE: PLEASE SEE COPY OF FS | | | 553.80(2)(B) WITH RESPECT TO DESIGN | | | PROFESSIONALS AND REPEAT COMMENTS FOR | | | CODE COMPLIANCE. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | FROM PLANS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. | | | ONE COPYOF OLD/VOIDED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | ** PLEASE SEE ANY OTHER POSSIBLE | | | COMMENTS FROM OTHER REVIEWS WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-07 |
Time |
05:51 |
Rev Time |
1.50 |
| Received By |
dpalmer |
Date |
2005-12-06 |
Time |
17:19 |
Sent To |
M |
|
| Notes |
| 2005-12-07 00:00:00 | ******** UNSAT ********** | | | | | | 1)NOTE: PLEASE SEE ELECTRICAL PLANS DO | | | NOT CORRELATE WITH BLDG PLANS/A-SHEETS. | | | PLEASE SEE THESE ARE TWO COMPLETELY | | | DIFERENT HOUSES. | | | PLEASE ADJUST. | | | PLEASE VERIFY WHAT APPEARS TO BE A | | | CLOSET OF SOME SORT IN WALK IN CLOSET OF | | | MASTER BEDRM AREA THAT APPEARS TO SHOW A | | | WATER HEATER?? | | | 215.5 | | | | | | 2)NOTE: PLEASE SEE MISSING EQUIPMENT | | | GROUNDING CONDUCTORS FROM MAINS TO SUB | | | PANEL(S) A AND B. | | | 250.110,250.122 | | | | | | 3)NOTE: PLEASE INDICATE ALL CONTINUOUS | | | LOADS ON POOL PANEL AT 125%. | | | PLEASE ALSO SEE THIS WILL CHANGE LOAD | | | AND EXCEED RATING OF OCP AND FEEDERS TO | | | POOL PANEL. PLEASE ADJUST AS NEW OCP AND | | | FEEDERS WILL NEED TO BE INCREASED. | | | 215.5,230.42,215..3,90.8 | | | | | | 4)NOTE: PLEASE SEE MISSING RECEPTS PER | | | 210.52. PLEASE SEE ONE SET OF PLANS HAVE | | | BEEN REDLINED WITH MANY OF THESE | | | LOCATIONS INDICATED. | | | | | | 5)NOTE: PLEASE SEE RECEPT MISSING PER | | | 210.52H FOR HALLWAY. 10' OR MORE OF | | | WALL. | | | | | | 6)NOTE: PLEASE SEE MISSING RECEPT PER | | | 210.52E, FRONT GFI. | | | | | | 7)NOTE: PLEASE CORRELATE THE # OF GDO | | | CIRCUITS ON PANEL SCHEDULE WITH THE | | | ACTUAL # NEEDED ON PLANS. PLEASE SEE | | | OTHER GARAGE. | | | PLEASE ALSO SEE PLANS DO NOT INDICATE | | | ANY RECEPTS AT THESE LOCATIONS. | | | 215.5, 430.24. TABLES). | | | | | | 8)NOTE: PLEASE SEE DISC'S FOR A/C CU | | | UNITS SHALL MEET 110.26 | | | | | | 9)NOTE: PLEASE SEE NFPA -72 11-8.3.5 | | | WHICH REQUIRES ALL SD'S TO BE INSTALLED | | | WITH-IN 12" OF A FLAT CEILING AREA. | | | PLEASE SEE "TRAY" CEILING AREA WOULD | | | REQUIRE TO THESE SD'S LOCATED AT THESE | | | AREAS IF HEY ARE 12" OR MORE HIGHER THAN | | | SURROUNDING CEILING AREA. SEE REDLINED | | | PLANS. | | | | | | 10)NOTE: PLEASE SEE 410.8 FOR TYPE OF | | | FIXTURE AND MIN CLEARENCES PERMITTED | | | ABOVE TUB/WHIRLPOOL. PLEASE PLACE NOTE | | | ON PLANS AS THIS IS SHOWN AS A "J-BOX" | | | FOR FUTURE. | | | | | | 11)NOTE: PLEASE SEE THE DETACHED GARAGE | | | WOULD REQUIRE MEANS OF DISCONNECT AS | | | REQUIRED UNDER 225.31-225.36. | | | PLEASE SEE DISCONNECTING MEANS MAY BE A | | | TOGGLE SWITCH TYPE DEVICE IF MEETING THE | | | EXCEPTIONS. | | | | | | 12)NOTE: PLEASE CORRELATE THE NUMBER OF | | | RECESSED LTS ON PANEL LOAD CALCULATIONS | | | WITH THE # OF FIXTURES ON PLANS. | | | 215.5,220.3B4 | | | | | | 13)NOTE: PLEASE CORRELATE ALL KW LOADS | | | FOR AHU'S WITH KW RAITNGS SHOWN ON | | | MECHANICAL PLANS. PLEASE MAKE ANY | | | ADJUSTMENTS NEEDED FOR OCP, AWG, LOAD | | | CALCS ETC. | | | 215.5 | | | | | | ** PLEASE KNOW, DEPENDING ON POSSIBLE | | | CHANGES IN "HOUSE PLANS" OR LAYOUT NOT | | | ALL COMMENTS MAY BE ON THIS REVIEW IF | | | THIS CHANGE OCCURS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | FROM PLANS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. | | | ONE COPYOF OLD/VOIDED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | ** PLEASE SEE ANY OTHER POSSIBLE | | | COMMENTS FROM OTHER REVIEWS WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-12-06 00:00:00 | IN FOR REVIEW. | | | NOTES TO FOLLOW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2008-03-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-28 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-28 |
Time |
16:21 |
Sent To |
Z |
|
| Notes |
| 2008-03-28 16:22:27 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-25 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-25 |
Time |
16:55 |
Sent To |
M |
|
| Notes |
| 2007-06-25 16:55:29 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-18 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-18 |
Time |
10:05 |
Sent To |
E |
|
| Notes |
| 2007-06-18 10:06:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-18 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-18 |
Time |
10:03 |
Sent To |
M |
|
| Notes |
| 2007-06-18 10:03:43 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-23 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-23 |
Time |
15:07 |
Sent To |
E |
|
| Notes |
| 2007-05-23 15:08:13 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-30 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-30 |
Time |
16:12 |
Sent To |
B |
|
| Notes |
| 2006-03-30 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-09 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-09 |
Time |
14:19 |
Sent To |
E |
|
| Notes |
| 2006-03-09 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-28 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-28 |
Time |
15:38 |
Sent To |
E |
|
| Notes |
| 2006-01-28 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-13 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-13 |
Time |
14:59 |
Sent To |
Z |
|
| Notes |
| 2006-01-13 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-06 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-06 |
Time |
14:33 |
Sent To |
E |
|
| Notes |
| 2005-12-06 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-27 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-11-18 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2005-11-18 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-27 |
Time |
14:56 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-06-27 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2007-06-27 14:58:25 | REVISION TO MECH. PLANS. | | | *** PROVISO *** | | | 1) DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS | | | OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE | | | SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET | | | STEEL OR OTHER APPROVED | | | MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. | | | PER 2004 FBC/R 309.1.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-18 |
Time |
13:39 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-06-18 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2007-06-18 13:42:56 | *** DENIED *** | | | 1) TWO COPY'S OF REVISED PLANS MUST BE SUBMITTED, ONLY | | | ONE COPY WAS SUBMITTED. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-31 |
Time |
10:02 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2006-01-31 |
Time |
10:02 |
Sent To |
P |
|
| Notes |
| 2006-01-31 00:00:00 | *** PROVISO *** | | | 1) DRYER VENT TERMINATION TO BE 4 FT. | | | FROM A/C CONDENSER UNITS. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-07 |
Time |
15:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-12-07 |
Time |
15:33 |
Sent To |
P |
|
| Notes |
| 2005-12-07 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE FORM | | | 600A-04 (2004), PER 2004 FBC 13-600.0 | | | ABC . | | | 2) FLOOR PLANS A-1 DO NOT MATCH MECH. | | | FLOOR PLAN. | | | 3) PLEASE CHECK RETURN AIR GRILL FOR | | | AHU #1, 30X18 APPEARS 100 SQUARE INCHES | | | TO SMALL. | | | 4) NEED TO FILE NOTICE OF COMMENCEMENT. | | | 5) DRYER VENT TERMINATION NEEDS TO BE 4 | | | FT. MIN. FROM A/C CONDENSER UNITS. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-02-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-02 |
Time |
10:00 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2006-02-02 |
Time |
10:00 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-12 |
Time |
12:07 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-12 |
Time |
12:07 |
Sent To |
B |
|
| Notes |
| 2005-12-12 00:00:00 | DENIED; | | | SHEET A-1 FLOOR PLAN DOESNOT MATCH RISER | | | DIAGRAM. | | | PLEASE HAVE PLUMBING RISER DIAGRAM ON A | | | LETTER HEAD PAGE NOT TAPED TO PLAN. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-31 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-03-31 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-03-31 |
Time |
12:54 |
Sent To |
PC |
|
| Notes |
| 2008-03-31 12:53:11 | ***APPROVED - LANDSCAPE PLAN SUBMITTAL (3/31/08)*** |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-01-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-28 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-28 |
Time |
08:34 |
Sent To |
I |
|
| Notes |
| 2006-01-28 00:00:00 | NOTE: STRUCTURE WILL BE CONSTRUCTED AT | | | THE MAXIMUM HEIGHT OF 33FT SEE A-2 | | | (FRONT ELEVATION) | | | | | | | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/DECK/SCREEN ENCLOSURE. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-12-05 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-12-05 |
Time |
15:26 |
Sent To |
I |
|
| Notes |
| 2005-12-05 00:00:00 | DENIED, | | | 1. THE STRUCTURE IS OVER THE HEIGHT | | | REQUIREMNT, PLANS SHOWS 34+ FT. | | | 2. STRUCTURE MUST BE 33FT (WITH | | | CHIMNEY). | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|