Plan Review Details - Permit 05110446
| Plan Review Stops For Permit 05110446 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2005-12-28 |
Time |
16:09 |
Rev Time |
0.33 |
| Received By |
amorse |
Date |
2005-12-28 |
Time |
16:09 |
Sent To |
PC |
|
| Notes |
| 2005-12-30 00:00:00 | ?PROVISO? | | | | | | POOL BARRIER REQUIREMENTS PER 424.2.17 & | | | R4101.17 | | | SHALL BE IN PLACE AT POOL FINAL | | | INSPECTION PER | | | R4101.19 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-12-09 |
Time |
12:44 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2005-12-09 |
Time |
12:41 |
Sent To |
P |
|
| Notes |
| 2005-12-09 00:00:00 | PLEASE SUBMIT DETAILS FOR THE PANEL | | | SHOWN ON THE SCHEMATIC, FEEDER AND CONDU | | | IT SIZE AND TYPE, PANEL RATING AND OCP, | | | PANEL SCHEDULE AND COMPUTED LOAD, ETC. | | | IF AN ELECTRIC HEATER IS TO BE INSTALLED | | | PLEASE SUBMIT CALCULATIONS FOR THE MAIN | | | SERVICE. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-11-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-23 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-23 |
Time |
15:43 |
Sent To |
E |
|
| Notes |
| 2005-11-23 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-17 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2005-11-17 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2005-12-15 |
Time |
13:06 |
Rev Time |
1.25 |
| Received By |
mperson |
Date |
2005-12-15 |
Time |
13:06 |
Sent To |
B |
|
| Notes |
| 2005-12-15 00:00:00 | DENIED | | | REFERENCE:FBC-2004 424.2 SWIMMING POOLS | | | | | | 1) COMPLY WITH FBC-2004 SEC 424.2 | | | PRIVATE SWIMMING POOLS.(ADD TO NOTES) | | | 2) FBC-2004 424.2.7.2 PUMPS AND | | | EQUIPMENT SHALL BE MOUNTED ON A | | | SUBSTANTIAL BASE IN A MANNER THAT WILL | | | ELIMINATE STRAIN ON PIPING.SLAB SHALL | | | BE A NOMINAL 4" THICK. (DETAIL)(ADD TO | | | NOTES) | | | 3)FBC-2004 424.2.9 WATER SUPPLY,LOCAL | | | ORD. #2853-95, BACKFLOW REQUIRED ON | | | WATER SERVICE.(ADD TO NOTES) | | | 4) FBC-2004 424.2.12.1 PRESSURE TESTS. | | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | | FITTINGS. (ADD TO NOTES) | | | 5) FBC-2004 424.2.13.2 JOINTS AND | | | CONNECTIONS,FBC PLMG. SEC. 605.21, | | | PURPLE PRIMER REQUIRED ON PVC PIPING. | | | (ADD TO NOTES) | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX (561)653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-11-22 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-11-22 |
Time |
16:54 |
Sent To |
I |
|
| Notes |
|
|
|