| Plan Review Stops For Permit 05110319 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-09-02 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-09-02 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2006-09-02 00:00:00 | | | | 1) 110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OF THE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | ====================================== | | | ) NUMBER OF FLOORS | | | ) SQ. FT. FOOTPRINT | | | ) SQ. FT. UNDER ROOF (TOTAL) | | | ) OCCUPANT LOAD | | | ) FLOOD ZONE | | | ) FLOOD ELEVATION | | | ) L.O.M.R. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-13 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-05-13 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-05-13 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-01-20 |
Time |
16:22 |
Rev Time |
0.75 |
| Received By |
mjacobs |
Date |
2006-01-20 |
Time |
16:06 |
Sent To |
PC |
|
| Notes |
| 2006-01-20 00:00:00 | PROVISO: | | | 1005.2 DOOR ENCROACHMENT. | | | DOORS OPENING INTO THE PATH OF EGRESS | | | TRAVEL SHALL NOT REDUCE THE REQUIRED | | | WIDTH TO LESS THAN ONE-HALF DURING THE | | | COURSE OF THE SWING. WHEN FULLY OPEN, | | | THE DOOR SHALL NOT PROJECT MORE THAN 7 | | | INCHES (178 MM) INTO THE REQUIRED WIDTH. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2005-11-21 |
Time |
13:38 |
Rev Time |
0.75 |
| Received By |
mjacobs |
Date |
2005-11-21 |
Time |
13:08 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | 1) SHEETS GSA 1 THROUGH 4 NEEDS TO BE | | | SIGNED/DATED AND SEALED BY THE ARCHITECT | | | OR ENGINEER RESPONSIBLE FOR THE | | | DRAWINGS.SEE F.S 472.025 AND | | | F.A.C. 61G15.23.002. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL (561)805-6726 | | | FAX (561) 659-8026 | | | [email protected]. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-31 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-31 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2006-08-31 00:00:00 | REV OK, STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-04-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-18 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-18 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-20 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-20 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-17 |
Time |
11:13 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-11-17 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2005-11-17 00:00:00 | ********* UNSAT ********** | | | | | | | | | 1)NOTE: PLEASE CORRELATE NEW OCP FROM | | | PANEL 8HB FOR NEW TRANSFORMER/ PANELS. | | | PLEASE SEE PANEL SCHEDULE SHOWS 125A | | | BRKR, HOWEVER NOTES TO THE RIGHT OF | | | PANEL SCHEDULE MENTIONS A NEW 3-POLE | | | 70A. | | | | | | 2)NOTE: | | | | | | 3)NOTE: PLEASE SHOW GROUNDING FOR | | | TRANSFORMER PER 250.30 FOR SEPARATELY | | | DERIVED SYSTEMS. | | | PLEASE ALSO SEE 250.66 FOR SIZING. | | | | | | 4)NOTE: PLEASE SHOW LOCATIONS OF | | | DISCONNECT AND TRANSFORMER. | | | LOCATIONS COULD NOT BE LOCATED ON PLANS. | | | PLEASE SEE 450.13B, 450.9 ETC. | | | PLEASE ALSO SEE 110.26 FOR MIN | | | CLEARENCES. (DISC ETC. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETED SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD VOIDED SHEETS SHOULD BE | | | SUBMITTED FOR REFERENCE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-09-06 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-09-06 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2006-09-06 00:00:00 | *****APPROVED***** | | | | | | | | | | | | | | | | | | 1.) STRUCTURES UNDERGOING CONSTRUCTION, | | | ALTERATION, OR DEMOLITION OPERATIONS | | | SHALL COMPOLY WITH NFPA 241. | | | | | | 2.) ACCUMULATIONS OF COMBUSTIBLE WASTE | | | MATERIALS, DUST, AND DEBRIS SHALL BE | | | REMOVED FROM THE STRUCTURE AND ITS | | | IMMEDIATE VICINITY AT THE END OF EACH | | | SHIFT OR MORE FREQUENTLY AS NECESSARY | | | FOR SAFE OPERATIONS. | | | | | | 3.) WHERE THE BUILDING IS PROTECTED BY | | | FIRE PROTECTION SYSTEMS, SUCH SYSTEMS | | | SHALL BE MAINTAINED OPERATIONAL AT ALL | | | TIMES DUDRING ALTERATION. | | | | | | | | | | | | | | | | | | LT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-23 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-23 |
Time |
14:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-01-20 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-01-20 |
Time |
14:45 |
Sent To |
|
|
| Notes |
| 2006-01-20 00:00:00 | PLANS APPROVED ON PRIOR DATE AND STAMPED | | | AT THIS TIME. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-21 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-21 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | ******PASSED****** | | | | | | ANY PROPOSED SPECIAL LOCKING | | | ARRANGEMENTS SHALL COMPLY WITH NFPA 101, | | | SEC. 7.2.1.6, 2003 EDITION. ACCESS | | | CONTROLLED EGRESS DOORS TO BE IN | | | COMPLIANCE WITH SEC. 7.2.1.6.2. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-15 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-15 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2006-08-28 00:00:00 | TO "BOB"#11 | | 2006-08-15 00:00:00 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-24 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2006-04-18 00:00:00 | TO "COMM" BD#55 | | 2006-03-24 00:00:00 | WAITING FOR COMM BOARD, NEEDS B |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-01-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-17 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-17 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2006-01-17 00:00:00 | TO "BOB"#9 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-11-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-15 |
Time |
18:30 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | TO "BOB"#9 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-09-05 |
Time |
10:35 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-09-05 |
Time |
10:35 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | MECH. REVISION TO PAGE M-1 & M-2 | | | *** PROVISO *** | | | PROVIDE RETURN AIR FOR ROOM 106. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-09 |
Time |
14:53 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-05-09 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2006-05-09 00:00:00 | REVISION TO MECH. PLANS PAGE M-1 AND | | | M-2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-20 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-20 |
Time |
15:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2005-11-28 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2005-11-28 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2005-11-28 00:00:00 | PLAN DENIED | | | 1) PLEASE PROVIDE DUCT SIZE FOR NEW DUCT | | | IN ROOMS 104 & 105. | | | 2) PLEASE INDICATE WHAT VAV ROOMS 104 & | | | 105 ARE TIED TO | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|