| 2005-12-13 00:00:00 | DENIED |
| | |
| | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT |
| | SHALL BE RECORDED AT PALM BEACH COUNTY |
| | COURTHOUSE AND A COPY SUBMITTED TO THIS |
| | OFFICE BEFORE A PERMIT CAN BE ISSUED. |
| | BLANK FORMS ARE AVAILABLE FROM THIS |
| | OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 3.SUBMIT TWO COPIES OF ENERGY CALCS TO |
| | THE 2004 FBC. |
| | |
| | 4.SUBMIT TWO COPIES OF PRODUCT |
| | APPROVALS FOR ALL WINDOWS, EXTERIOR |
| | DOORS, OVERHEAD DOOR, GLASS BLOCK |
| | ROOFING, AND SHUTTERS. |
| | |
| | 5.ALL PRODUCT APPROVALS SUBMITTED |
| | SHALL HAVE THE FOLLOWING STATE PRODUCT |
| | APPROVAL ATTACHED. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 6.SHOW SIZE AND TYPE OF EXISTING |
| | WINDOW FOR BEDROOM #2.SHOW HOW THE |
| | SIZE WILL COMPLY WITH R-310.1 FBC 2004 |
| | |
| | 7.SHOW SIZE AND LOCATION OF ATTIC |
| | ACCESS R-807 FBC 2004 |
| | |
| | 8.R613.6.2 MASONRY, CONCRETE OR OTHER |
| | STRUCTURAL SUBSTRATE. |
| | ANCHORS SHALL BE SECURELY FASTENED |
| | DIRECTLY INTO THE MASONRY, CONCRETE OR |
| | OTHER STRUCTURAL SUBSTRATE MATERIAL. |
| | UNLESS OTHERWISE TESTED, BUCKS SHALL |
| | EXTEND BEYOND THE INTERIOR FACE OF THE |
| | WINDOW OR DOOR FRAME SUCH THAT FULL |
| | SUPPORT OF THE FRAME IS PROVIDED. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |