Plan Review Details - Permit 05110247
| Plan Review Stops For Permit 05110247 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-15 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-04-15 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-04-15 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2006-04-15 00:00:00 | ADDRESS CORRECTED TO 350 S. AUSTRALIAN | | | AVE.CREATED AS AN EXTENSION TO THE | | | PCN. | | | | | 2006-01-25 00:00:00 | NEEDS , AS PLANS AND APPLICATION FOR | | | PHASE II IS SHOWN AS 350 S AUSTRALIAN, | | | HOWEVER, SYSTEM INDICATES 300. EXTENSION | | | NEEDED FOR SAME PCN? |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-17 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-12-17 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-12-17 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2006-12-17 15:28:55 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | | ARE NUMBERED AS PER THE BUILDING PLAN | | | REVIEW OF 4/22/06: | | | | | | 1) WORKING DRAWING REVIEW ONLY.NO PERMIT CAN BE | | | ISSUED UNTIL THE PERMIT APPLICATION AND FEES ARE | | | SUBMITTED. | | | | | | 2) INFORMATIVE: | | | A NOTICE OF COMMENCEMENT SHALL BE RECORDED, COUNTY | | | IMPACT FEES PAID AND A SIGNED THRESHOLD INSPECTION | | | AGREEMENT SUBMITTED BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3) FBC 13-103.1.2THIS COMMENT HAS NOT BEEN PROPERLY | | | ADDRESSED.IT IS NOTED THAT THE NAME AND LICENSE | | | NUMBER OF EACH DESIGN PROFESSIONAL HAS BEEN ADDED TO | | | THE ENERGY CODE COMPLIANCE FORM, BUT THE SIGNATURES AND | | | DATES REQUIRED TO CERTIFY CODE COMPLIANCE HAVE NOT BEEN | | | INCLUDED.BEFORE A BUILDING PERMIT CAN BE ISSUED, THE | | | 'CERTIFICATION' BOX ON SHEET 2 OF THE SUBMITTED ENERGY | | | CODE COMPLIANCE FORMS SHALL BE SIGNED AND DATED BY THE | | | 'PREPARER' AND THE BUILDING OWNER, THE OWNER'S | | | ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY DESIGNATED | | | BY THE OWNER. ALSO, SHEET 1 SHOULD BE COMPLETED WITH | | | THE PERMIT NUMBER (05110247). | | | | | | 19) FBC 1606.1TRANSFORMER VAULT DOOR 117A.SUBMITTAL | | | OF PRODUCT APPROVAL NOA# 02-0222.06 (FL2198.3) FOR A | | | 6070 DOUBLE DOOR IS NOTED BUT SHEETS 1 AND 2 OF 11 BOTH | | | STATE MAXIMUM POSITIVE AND NEGATIVE DESIGN PRESSURES OF | | | +60 PSF AND -60 PSF FOR THE PROPOSED DOOR.THE | | | PRESSURES REQUIRED BY THE SUBMITTED RWDI WIND LOAD | | | STUDY REPORT FOR THE SOUTH ELEVATION OF THE PHASE II | | | BUILDING ARE +65 PSF AND -65 PSF.SUBMIT AN | | | ALTERNATIVE PRODUCT APPROVAL. | | | | | | 21) FBC 1606.1HORIZONTAL SLIDER WINDOW W2, W4, W6, | | | W6.1.THE RESPONSE IS NOTED AS STATING THAT A CUT DOWN | | | EFCO CORP. SERIES 3014 SLIDING GLASS DOOR WILL BE USED | | | FOR W2 AND W6 WHERE THE REQUIRED DESIGN PRESSURE IS 95 | | | PSF, AND AN EFCO CORP. SERIES 3500 HORIZONTAL SLIDING | | | WINDOW WILL BE USED FOR W2, W4, W6, W6.1 WHERE THE | | | REQUIRED DESIGN PRESSURE IS LESS THAN 95 PSF.NO | | | PRODUCT APPROVAL WAS SUBMITTED FOR EFCO CORP. SERIES | | | 3014 SLIDING GLASS DOOR AND ONLY ONE COPY OF THE | | | PRODUCT APPROVAL (ONE COPY ATTACHED TO THE COMMENT | | | RESPONSE LETTER) FOR EFCO CORP. SERIES 3500 HORIZONTAL | | | SLIDING WINDOW WERE SUBMITTED.SUBMIT THREE COPIES OF | | | THE PRODUCT APPROVALS INCLUDING THE FLORIDA STATEWIDE | | | PRODUCT APPROVAL COVER SHEET (FL####).FOR EASE OF | | | REFERENCE A COPY OF THE FLORIDA STATEWIDE PRODUCT | | | APPROVAL COVER SHEET FOR EFCO CORP. SERIES 3500 | | | HORIZONTAL SLIDING WINDOW HAS BEEN INSERTED INTO THE | | | COMMENT RESPONSE LETTER ATTACHMENT PACKET FOR YOUR | | | USE. | | | | | | 22) INFORMATIVE: | | | FBC 1606.1PRODUCT APPROVAL SUBMITTAL. ALL THREE | | | COPIES OF THE SUBMITTED DOCUMENT BINDERS INCLUDE SOME | | | INCOMPLETE PRODUCT APPROVAL DOCUMENTS.PLEASE REVIEW | | | THE BINDERS TO ENSURE THAT A PRODUCT APPROVAL HAS BEEN | | | SUBMITTED FOR EACH TYPE OF PRODUCT THAT IS TO BE | | | INSTALLED.PLAN REVIEW WILL ONLY ENSURE THAT THE | | | BINDERS INCLUDE PRODUCT APPROVALS TO COVER THE WORST | | | CASE.FOR, EXAMPLE IF ONLY A LARGE MISSILE IMPACT | | | PRODUCT APPROVAL IS SUBMITTED, THAT WOULD MEET PLAN | | | REVIEW REQUIREMENTS BUT IT WOULD MEAN THAT PRODUCT | | | WOULD HAVE TO BE USED EVEN WHERE LARGE MISSILE IMPACT | | | RATING IS NOT REQUIRED.REMOVE, FROM EACH BINDER, ALL | | | PRODUCT APPROVAL DOCUMENTS WHICH ARE NO LONGER | | | APPLICABLE DUE TO THE SUBSTITUTIONS MADE.ALSO, WHERE | | | MULTIPLE OPTIONS ARE COVERED BY A PRODUCT APPROVAL, THE | | | APPROPRIATE PAGES OF THE PRODUCT APPROVAL SHALL BE | | | MARKED TO SHOW WHICH PRODUCT OPTIONS/SIZES ARE PROPOSED | | | SO THAT THE APPLICABLE DESIGN PRESSURE RATING CAN BE | | | DETERMINED. | | | | | | 23) -PROVISO- | | | WINDOW WALLS: THE WINDOW SHOP DRAWING SUBMITTAL SHALL | | | INCLUDE A STRUCTURAL MULLION.THE MULLION MUST BE | | | CAPABLE OF SPANNING HORIZONTALLY ACROSS THE ENTIRE | | | WIDTH OF THE OPENING FOR THOSE WINDOWS THAT EXCEED THE | | | MAXIMUM HEIGHT STATED IN THE SUBMITTED MIAMI WALL | | | SYSTEMS INC. FIXED WINDOW LARGE MISSILE IMPACT SERIES | | | 101 AND SMALL MISSILE IMPACT SERIES 101 | | | PRODUCT APPROVAL NOA'S 03-0415.18 AND 05-0420.01. | | | | | | 24) -PROVISO- | | | SLIDING GLASS DOORS:THE WINDOW/DOOR SUBCONTRACTOR | | | SHALL PROVIDE RATIONAL ANALYSIS FROM A FLORIDA | | | REGISTERED ENGINEER TO JUSTIFY THE USE OF THE PROPOSED | | | SLIDING GLASS DOOR IN SIZES THAT EXCEED THE MAXIMUM IN | | | THE SUBMITTED EFCO CORP. SERIES S-3005 SLIDING GLASS | | | DOOR PRODUCT APPROVAL NOA 02-0722.02, AND MIAMI WALL | | | SYSTEMS INC. SERIES 100 SLIDING GLASS DOOR PRODUCT | | | APPROVAL NOA'S 04-0908.02 AND 01-1108.03. | | | NOTE: MISSILE IMPACT RATING FOR THESE LARGER SIZES | | | CANNOT BE JUSTIFIED BY RATIONAL ANALYSIS.MISSILE | | | IMPACT TEST RESULTS MUST BE SUBMITTED. | | | | | | 25) -PROVISO- | | | HORIZONTAL SLIDER WINDOWS: IT IS NOTED THAT 'CUT-DOWN' | | | SLIDING GLASS DOORS WILL BE USED FOR THOSE HORIZONTAL | | | SLIDER WINDOWS WHICH EXCEED 6'-6" WIDE X 6'-0" HIGH | | | (FOR EXAMPLE W2, W2.1, W3, W3.1, W3.2(SLIDER?), W3.P, | | | W4, W4.1, W5, W5.1, W5.P, W6, W6.1). | | | | | | 26) -PROVISO- | | | FIXED WINDOWS:THE WINDOW SHOP DRAWING SUBMITTAL SHALL | | | INCLUDE A STRUCTURAL MULLION.THE MULLION MUST BE | | | CAPABLE OF SPANNING HORIZONTALLY ACROSS THE ENTIRE | | | WIDTH OF THE OPENING FOR THOSE WINDOWS THAT EXCEED THE | | | 6'-0" MAXIMUM HEIGHT STATED IN THE SUBMITTED MIAMI WALL | | | SYSTEMS INC. SERIES 122 ALUMINUM FIXED WINDOW PRODUCT | | | APPROVAL NOA 04-0322.09. | | | | | | 28) STOREFRONT WINDOWS.PLEASE NOTE THAT THE SUBMITTED | | | EFCO CORP. SERIES 5600 ALUMINUM CURTAIN WALL PRODUCT | | | APPROVAL NOA# 02-0304.01 (FL 1561.1) IS RATED FOR SMALL | | | MISSILE IMPACT ONLY.IT CAN ONLY BE USED IN LOCATIONS | | | HIGHER THAN 30 FEET ABOVE GRADE.PLEASE NOTE THAT | | | SHEET A6-61 REFERS TO THE FIRST FLOOR STOREFRONT AS SF1 | | | AND THE ROOF (LANTERN) STOREFRONT AS SF2 WHICH IS | | | CONSISTENT WITH THE BUILDING ELEVATIONS.THE | | | EXCEPTIONS ARE SHEETS A4-06 AND A4-11 SHOULD BE REVISED | | | AS THEY REFER TO THE ROOF LANTERN STOREFRONT AS SF1. | | | | | | 29) TO EXPEDITE REVIEW OF A RESUBMITTAL WHICH REQUIRES | | | NEW PLANS IN ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | | OLD SHEETS SHALL BE REMOVED AND THE NEW SHEETS | | | INSERTED.ONE COPY OF EACH OLD SHEET SHOULD BE | | | STAPLED/CLIPPED TO THE REMAINING OLD SHEETS, TO FORM A | | | SET OF 'OLD/VOID SHEETS', FOR COMPARISON OF REVISIONS | | | WHEN REVIEWING THE RESUBMITTED PLANS. | | | | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO TELEPHONE: | | | (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-04-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-04-22 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2006-04-15 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2006-04-15 00:00:00 | BUILDING PLAN REVIEW | | | *******DENIED******* | | | ROBERT BROWN(561) 805 6652 | | | E-MAIL: [email protected] | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | F.S.= FLORIDA (STATE) STATUTE | | | | | | 1) WORKING DRAWING REVIEW ONLY.NO | | | PERMIT CAN BE ISSUED UNTIL THE PERMIT | | | APPLICATION AND FEES ARE SUBMITTED. | | | | | | 2) INFORMATIVE: | | | A NOTICE OF COMMENCEMENT SHALL BE | | | RECORDED, COUNTY IMPACT FEES PAID AND A | | | SIGNED THRESHOLD INSPECTION AGREEMENT | | | SUBMITTED BEFORE A PERMIT CAN BE ISSUED. | | | | | | 3) FBC 13-103.1.1.1ONLY THE | | | MECHANICAL SYSTEM DESIGNER'S NAME AND | | | LICENSE NUMBER ARE CURRENTLY INCLUDED ON | | | SHEET 2 OF THE ENERGY CODE COMPLIANCE | | | FORM.ALL OF THE PROFESSIONALS | | | RESPONSIBLE FOR THE DESIGN OF THE | | | BUILDING SHELL AND THE ELECTRICAL, | | | LIGHTING, MECHANICAL AND PLUMBING | | | SYSTEMS SHALL EACH SIGN THE ENERGY CODE | | | COMPLIANCE FORM, IN THE SPACE PROVIDED, | | | TO CERTIFY COMPLIANCE. | | | ALSO, SHEET 1 SHOULD BE COMPLETED WITH | | | THE CORRECT PROJECT ADDRESS (350 S | | | AUSTRALIAN AVE), ZIP CODE (33401) AND | | | PERMIT NUMBER (05110247). | | | | | | 4) 471.023 F.S.STRUCTURAL PLANS.ADD | | | THE CERTIFICATE OF AUTHORIZATION NUMBER | | | (EB 25930) FOR ECHELON ENGINEERING, LLC | | | TO EACH SHEET.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ENGINEERING SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. ADD | | | THE NUMBER TO EACH SHEET.THIS MAY BE | | | ADDED BY HAND. | | | | | | 5) FBC* 104.2.1SHEET CD-02, 2ND - 5TH | | | FLOORS, EXITING PLAN.THERE ARE TWO | | | DOOR WIDTH NOTES BELOW THE PLAN WHICH | | | POINT TO EXITING VIA THE BALCONY OF UNIT | | | E2 AT THE NORTH-WEST CORNER OF THE | | | BUILDING.THE NOTES ARE NOT APPLICABLE | | | TO THE 2ND - 5TH CONFIGURATION.REMOVE | | | THE NOTES. | | | | | | 6) FBC* 104.2.1SHEET A1-01, GROUND | | | FLOOR PLAN.THE LOCATION OF THE | | | ENTRANCE DOOR TO UNIT F1 IS NOT SHOWN | | | | | | 7) FBC* 704.1SHEETS A1-01 AND A1.01B, | | | GROUND FLOOR PLAN.THERE IS NO LINE | | | TYPE SHOWN ON THE PARTITION LEGEND TO | | | SHOW THE FIRE RESISTANCE RATING OF THE | | | TRANSFORMER VAULT. | | | | | | 8) FBC* 704.1SHEET A1-01A, GROUND | | | FLOOR PLAN.THERE IS NO LINE TYPE | | | DIFFERENCE ON THE PLAN OR THE PARTITION | | | LEGEND TO DIFFERENTIATE BETWEEN 1 HOUR | | | AND 2 HOUR RATED WALLS. | | | | | | 9) RECOMMENDATION:SHEETS A1-01 TO | | | A1-17, FLOOR PLANS. FOR CLARITY AT THE | | | FIRE RATED WALL LOCATIONS, PLEASE | | | CONSIDER CONTINUING THE RELEVANT LINE | | | TYPE (SEE PARTITION LEGEND) THROUGH ANY | | | ASSOCIATED CONCRETE WALL, COLUMN, | | | SHEARWALL ETC SHOWN ON THE PLANS. ALSO, | | | THE LINE TYPE FOR THE EXPANSION JOINT, | | | ACROSS THE PARKING DECK, ON SHEETS A1-02 | | | AND A1-04 SHOULD BE CHANGED FOR CLARITY. | | | | | | 10) FBC* 104.2.1SHEET A1-02, 2ND, 3RD, | | | 5TH FLOOR PLAN.THERE APPEARS TO BE A | | | SECTION OF WALL MISSING ALONG GRID A AT | | | GRID 25. | | | | | | 11) FBC* 104.2.1FLOOR PLANS.THERE | | | APPEARS TO BE NO SPOT LEVELS SHOWN ON | | | THE PLANS.IN PARTICULAR, ADD SPOT | | | LEVELS TO SHEETS A1-06, A1-17 AND A1-18 | | | WHICH ARE THE 6TH FLOOR, MAIN ROOF AND | | | UPPER ROOF PLANS, RESPECTIVELY. | | | | | | 12) FBC 1608.2.2SHEETS A4-10, A6-20 | | | AND A7-20.THE GUARDRAIL SHALL BE | | | DESIGNED AND CONSTRUCTED FOR A | | | CONCENTRATED LOAD OF 200 LB APPLIED IN | | | ANY DIRECTION AT THE TOP OF THE | | | GUARDRAIL, A CONCENTRATED HORIZONTAL | | | LOAD OF 200 LB APPLIED ON A 1 SQ FT AREA | | | AT ANY POINT, AND A LINE LOAD OF 50 PLF | | | APPLIED HORIZONTALLY AT THE REQUIRED | | | GUARDRAIL HEIGHT WITH A SIMULTANEOUS | | | LINE LOAD OF 100 PLF APPLIED VERTICALLY | | | DOWNWARD ON THE TOP OF THE GUARDRAIL. | | | THESE LOADS SHALL NOT BE APPLIED | | | SIMULTANEOUSLY (UNLESS NOTED ABOVE) BUT | | | SHALL BE APPLIED INDIVIDUALLY TO PRODUCE | | | MAXIMUM STRESS IN EACH OF THE COMPONENTS | | | OR SUPPORTS.ANNOTATE THE PLANS TO | | | ENSURE THIS REQUIREMENT IS MET. | | | | | | 13) FBC 1606.1SHEET A6-20, DETAIL 9. | | | THE ATTACHMENT OF THE STUCCO CORNICE | | | FRAMING SHALL BE SPECIFIED ON THE DETAIL | | | OR A NOTE ADDED TO STATE THAT THE | | | FRAMING AND ATTACHMENT DETAILS WILL BE | | | SUBMITTED ON SPECIALIST SHOP DRAWINGS | | | AFTER FIRST BEING REVIEWED BY THE | | | DESIGNER OF RECORD.ANNOTATE THE DETAIL | | | | | | 14) FBC 1015.2SHEET A6-20, DETAIL 11. | | | THE EFFECTIVE HEIGHT OF THE GUARDRAIL IS | | | REDUCED BY THE PRESENCE OF THE CONCRETE | | | UPTURNED BEAM WHICH FORMS A LEDGE ON THE | | | INSIDE FACE OF THE GUARDRAIL.TO | | | PREVENT BUILDING OCCUPANTS FROM STANDING | | | ON THIS LEDGE, EITHER PROVIDE A 45 | | | DEGREE CHAMFER ON THE INSIDE EDGE OF THE | | | CONCRETE UPSTAND OR PROVIDE SOME OTHER | | | MEANS TO DISCOURAGE CLIMBING. | | | | | | 15) FBC 1608.2.1SHEET A7-20,THE | | | HANDRAIL SHALL BE DESIGNED AND | | | CONSTRUCTED FOR A CONCENTRATED LOAD OF | | | 200 LB AND A LINE LOAD OF 50 PLF.THESE | | | LOADS SHALL NOT BE APPLIED | | | SIMULTANEOUSLY BUT SHALL BE APPLIED | | | INDIVIDUALLY AT ANY POINT, AND IN ANY | | | DIRECTION, TO PRODUCE MAXIMUM STRESS IN | | | EACH OF THE COMPONENTS OR SUPPORTS. | | | AMEND/ANNOTATE THE PLANS TO ENSURE THIS | | | REQUIREMENT IS MET. | | | | | | 16) FBC 1601.1SHEET L7-04, PAVILION. | | | ADD A PAVILION FOOTING DETAIL. | | | | | | 17) FBC 1606.1PRODUCT APPROVALS | | | GENERALLY.MANY OF THE SUBMITTED | | | PRODUCT APPROVALS INCLUDE MORE THAN ONE | | | OPTION WITH DIFFERENT DESIGN PRESSURE | | | RATINGS (WIND PRESSURE IN PSF).MARK | | | THE PRODUCT APPROVAL TO SHOW WHICH | | | OPTION (DESIGN PRESSURE RATING) IS | | | APPLICABLE.PLEASE DO NOT USE | | | HIGHLIGHTER PEN BECAUSE IT DOES NOT SHOW | | | UP WHEN THE DOCUMENTS ARE SCANNED FOR | | | ARCHIVING AT THE END OF THE PROJECT. | | | | | | 18) FBC 1504.1ROOF COVERING. SUBMITTAL | | | OF MANUFACTURER'S PRODUCT DATA IS NOTED | | | BUT NO OTHER DOCUMENTATION WAS INCLUDED. | | | SUBMIT PRODUCT APPROVAL(S) FOR THE | | | PROPOSED ROOF SYSTEM(S). | | | | | | 19) FBC 1606.1TRANSFORMER VAULT DOOR | | | 117A.THE DOOR SCHEDULE, SHEET A8-10, | | | SPECIFIES A PAIR OF 3070 HOLLOW METAL | | | DOORS.NO PRODUCT APPROVAL WAS | | | SUBMITTED FOR A PAIR OF 3070 HOLLOW | | | METAL DOORS.THE SUBMITTED CURRIES | | | COMPANY COMMERCISL STEEL DOOR PRODUCT | | | APPROVAL IS FOR A SINGLE 3070 DOOR. | | | | | | 20) FBC 1606.1SLIDING GLASS DOOR S1. | | | ACCORDING TO THE SUBMITTED RWDI WIND | | | LOAD STUDY REPORT, THERE ARE LOCATIONS | | | ON THE NORTH AND SOUTH ELEVATION WHERE | | | THIS DOOR WILL BE SUBJECT TO NEGATIVE | | | WIND PRESSURE OF -115 PSF.DRAWING | | | SHEET 1 OF THE SUBMITTED MIAMI WALL | | | SYSTEMS INC SERIES 100 ALUMINUM SLIDING | | | GLASS DOOR PRODUCT APPROVAL NOA# | | | 04-0908.02, STATES THAT THE MAXIMUM | | | DESIGN PRESSURE RATING FOR THE WINDOW IS | | | 100 PSF.PROVIDE RATIONAL ANALYSIS TO | | | JUSTIFY THIS OR PROVIDE AN ALTERNATIVE | | | PRODUCT APPROVAL. | | | | | | 21) FBC 1606.1HORIZONTAL SLIDER WINDOW | | | W2, W4, W6, W6.1.ACCORDING TO THE | | | SUBMITTED RWDI WIND LOAD STUDY REPORT, | | | THERE ARE LOCATIONS WHERE THESE WINDOWS | | | WILL BE SUBJECT TO A POSITIVE AND/OR | | | NEGATIVE WIND PRESSURE OF 95 PSF. | | | DRAWING SHEET 1 OF THE SUBMITTED MIAMI | | | WALL SYSTEMS INC SERIES 106 ALUMINUM | | | HORIZONTAL SLIDER WINDOW PRODUCT | | | APPROVAL NOA# 04-1122.02, STATES THAT | | | THE MAXIMUM DESIGN PRESSURE RATING FOR | | | THE WINDOW IS 90 PSF.PROVIDE RATIONAL | | | ANALYSIS TO JUSTIFY THIS OR PROVIDE AN | | | ALTERNATIVE PRODUCT APPROVAL. | | | | | | 22) INFORMATIVE: | | | FBC 1606.1PRODUCT APPROVAL SUBMITTAL. | | | ALL THREE COPIES OF THE SUBMITTED | | | DOCUMENT BINDERS INCLUDE SOME INCOMPLETE | | | PRODUCT APPROVAL DOCUMENTS.PLEASE | | | REVIEW THE BINDERS TO ENSURE THAT A | | | PRODUCT APPROVAL HAS BEEN SUBMITTED FOR | | | EACH TYPE OF PRODUCT THAT IS TO BE | | | INSTALLED.PLAN REVIEW WILL ONLY ENSURE | | | THAT THE BINDERS INCLUDE PRODUCT | | | APPROVALS TO COVER THE WORST CASE.FOR, | | | EXAMPLE IF ONLY A LARGE MISSILE IMPACT | | | PRODUCT APPROVAL IS SUBMITTED, THAT | | | WOULD MEET PLAN REVIEW REQUIREMENTS BUT | | | IT WOULD MEAN THAT PRODUCT WOULD HAVE TO | | | BE USED EVEN WHERE LARGE MISSILE IMPACT | | | RATING IS NOT REQUIRED. | | | | | | 23) -PROVISO- | | | WINDOW WALLS: THE WINDOW SHOP DRAWING | | | SUBMITTAL SHALL INCLUDE A STRUCTURAL | | | MULLION.THE MULLION MUST BE CAPABLE OF | | | SPANNING HORIZONTALLY ACROSS THE ENTIRE | | | WIDTH OF THE OPENING FOR THOSE WINDOWS | | | THAT EXCEED THE MAXIMUM HEIGHT STATED IN | | | THE SUBMITTED MIAMI WALL SYSTEMS INC. | | | FIXED WINDOW LARGE MISSILE IMPACT SERIES | | | 101 AND SMALL MISSILE IMPACT SERIES 101 | | | PRODUCT APPROVAL NOA'S 03-0415.18 AND | | | 05-0420.01. | | | | | | 24) -PROVISO- | | | SLIDING GLASS DOORS:THE WINDOW/DOOR | | | SUBCONTRACTOR SHALL PROVIDE RATIONAL | | | ANALYSIS FROM A FLORIDA REGISTERED | | | ENGINEER TO JUSTIFY THE USE OF THE | | | PROPOSED SLIDING GLASS DOOR IN SIZES | | | THAT EXCEED THE MAXIMUM IN THE SUBMITTED | | | MIAMI WALL SYSTEMS INC. SERIES 100 | | | SLIDING GLASS DOOR PRODUCT APPROVAL | | | NOA'S 04-0908.02 AND 01-1108.03. | | | NOTE: MISSILE IMPACT RATING FOR THESE | | | LARGER SIZES CANNOT BE JUSTIFIED BY | | | RATIONAL ANALYSIS.MISSILE IMPACT TEST | | | RESULTS MUST BE SUBMITTED. | | | | | | 25) -PROVISO- | | | HORIZONTAL SLIDER WINDOWS: IT IS NOTED | | | THAT 'CUT-DOWN' SLIDING GLASS DOORS WILL | | | BE USED FOR THOSE HORIZONTAL SLIDER | | | WINDOWS WHICH EXCEED 6'-6" WIDE X 6'-0" | | | HIGH (FOR EXAMPLE W2, W2.1, W3, W3.1, | | | W3.2(SLIDER?), W3.P, W4, W4.1, W5, W5.1, | | | W5.P, W6, W6.1). | | | | | | 26) -PROVISO- | | | FIXED WINDOWS:THE WINDOW SHOP DRAWING | | | SUBMITTAL SHALL INCLUDE A STRUCTURAL | | | MULLION.THE MULLION MUST BE CAPABLE OF | | | SPANNING HORIZONTALLY ACROSS THE ENTIRE | | | WIDTH OF THE OPENING FOR THOSE WINDOWS | | | THAT EXCEED THE 6'-0" MAXIMUM HEIGHT | | | STATED IN THE SUBMITTED MIAMI WALL | | | SYSTEMS INC. SERIES 122 ALUMINUM FIXED | | | WINDOW PRODUCT APPROVAL NOA 04-0322.09. | | | | | | 27) TO EXPEDITE REVIEW OF A RESUBMITTAL | | | WHICH REQUIRES NEW PLANS IN ORDER TO | | | ADDRESS THE ABOVE COMMENTS, THE OLD | | | SHEETS SHALL BE REMOVED AND THE NEW | | | SHEETS INSERTED.ONE COPY OF EACH OLD | | | SHEET SHOULD BE STAPLED/CLIPPED TO THE | | | REMAINING OLD SHEETS, TO FORM A SET OF | | | 'OLD/VOID SHEETS', FOR COMPARISON OF | | | REVISIONS WHEN REVIEWING THE RESUBMITTED | | | PLANS. | | | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | | | END OF REVIEW COMMENTS | | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | | TELEPHONE: (561) 805 6652ROBERT BROWN | | | E-MAIL: [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-11-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-05 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-20 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2006-11-05 16:34:06 | **** THE EDGE PHASE II ** 17 STORY ** | | | | | | ********** UNSAT 2ND REVIEW *************** | | | | | | ** PLEASE KNOW PLANS ARE NOT COMPLETE AT THIS TIME FOR | | | CODE COMPLIANCE. | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH NEW COMMENTS BASED ON | | | PLANS SUBMITTED. | | | ** PLEASE SEE NOTE BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH NEW NOTES ADDED TO THE BOTTOM OF | | | THE REVIEW. | | | | | | | | | 1) NOTE: OK. | | | | | | 2) NOTE:NO, PLEASE SEE TITLE BLOCKS FOR | | | MECHANICAL/PLUMBING COMPANY DOES NOT CONTAIN THE | | | CORRECT LICENSURE INFORMATION AS REQUIRED. PLEASE ALSO | | | KNOW IT IS KNOWN TO THIS OFFICE THAT CEASE AND DESIST | | | LETTERS WERE SENT TO THE COMPANY AND ENGINEERS AS SHOWN | | | ON RECORD. PLEASE SEE NEW PLANS WERE SUBMITTED EVEN | | | AFTER THIS WAS ISSUED BY THE STATE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS. PLEASE KNOW THAT ONE COMPLETE | | | SET OF PLANS WILL BE FORWARDED TO THE BOARD AS | | | REQUESTED BY THE STATE ONCE ALL REVIEWS ARE COMPLETED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING LICENSE INFORMATION REQUIRED ON | | | TITLE BLOCKS FOR CONSULTING ENGINEERING FIRM AS | | | REQUIRED UNDER FLORIDA STATUES 471.023, FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002. | | | PLEASE SEE COMPANIES AS LISTED ARE PROVIDING | | | ENGINEERING SERVICES" AND NO | | | CERTIFICATE OF AUTHORIZATION NUMBER COULD BE LOCATED ON | | | STATE WEBSITE OF DEPARTMENT OF BUSINESS AND | | | PROFESSIONAL REGULATION. (DBPR). | | | PLEASE KNOW AS REQUIRED BY THE SAID FLORIDA STATUES AND | | | LICENSING UNDER FS | | | 468 FOR THIS OFFICE, ONE SET OF MEP PLANS ARE BEING | | | RETAINED AND SHALL BE FORWARDED TO THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS FOR REVIEW OF SAID REQUIREMENTS. | | | WE HAVE CONSULTED WITH THE FBPE'S ON THE ABOVE. PLEASE | | | CONTACT MR. JERRY ONGLEY AND MR. DOUGLAS SUNSHINE IF | | | THERE ARE ANY QUESTIONS. | | | ** PLEASE KNOW, THESE REQUIREMENTS ARE ALSO FOR THE | | | OTHER CONSULTING COMPANIES AS LISTED ON SAID TITLE | | | BLOCKS. | | | | | | 3) NOTE:NO, PLEASE SUBMIT ALL AS PREVIOUS REQUESTED. | | | PLEASE SEE REVIEW OF CODE COMPLAINT ITEMS CAN NOT BE | | | VERIFIED AS THERE HAVE BEEN CHANGES SINCE PHASE ONE | | | PLANS PER RESPONSE AND REVIEW OF THESE DO NOT | | | CORRELATE.110.3, 90.7, NFPA-20 ETC. | | | FBC ADMIN SECTION 104.2.1 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE SPECS SUBMITTED FOR FIRE PUMP CONTAIN THE | | | TITLE AND THE RESPONSIBLE ENGINEER AS STEVEN FELLER OF | | | FELLER ENGINEERING. STEVEN FELLER AND FELLER | | | ENGINEERING ARE THE CONSULTING ENGINEERS OF PHASE-ONE. | | | PLEASE CORRECT ALL SUBMITTALS FOR FIRE PUMP, FIRE PUMP | | | CONTROLLER ETC. | | | | | | 4) NOTE: NO, RESPONSE MENTIONS THIS PROJECT IS UNDER | | | THE 2001 FBC WHICH WAS NOT THE REQUEST. PLEASE LIST THE | | | FOLLOWING CODES ON PLANS RELEVANT TO DESIGN AS THE | | | FOLLOWING CODES ARE IN EFFECT FOR THIS PROJECT UNDER | | | THE 2001 FBC. | | | | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE BE SURE PLANS REFERENCE ALL CURRENT CODE IN | | | EFFECT FOR THIS PROJECT. PLEASE KNOW WE ARE CURRENTLY | | | UNDER THE 2003 NFPA-101, 2002 NFPA-72 AND 2002 NFPA-70 | | | ETC. | | | | | | 5) NOTE:NO, PLEASE SEE NOW DOORS ARE EVEN MISSING | | | FROM ELECTRICAL FLOOR PLANS? PLEASE KNOW THE ENTRANCE | | | LOCATION FOR ACCESS IS ALSO A MAIN CONCERN. RESPONSE | | | SPEAKS OF EGRESS WHICH IS ALSO IMPORTANT, HOWEVER | | | OBTAINING ACCESS TO THE MAIN ELECTRICAL ROOM IS MOST | | | IMPORTANT IF THE FIRE DEPT PERSONNEL IS IN NEED OF | | | SHUTTING DOWN POWER. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE KNOW, ENTRANCE TO MAIN ELECTRICAL ROOM SHALL BE | | | DETERMINED BY THIS OFFICE AND FIRE MARSHAL'S OFFICE FOR | | | ACCESSIBILITY. PLANS INDICATE ACCESS GRANTED THROUGH | | | GARAGE AREA AND TRAVEL DISTANCE IN BLDG MAY REQUIRED A | | | MORE ACCESSIBLE MEANS TO MAIN ELECTRICAL ROOM. | | | ** PLEASE SEE POSSIBLE FIRE REVIEW COMMENTS. | | | | | | 6) NOTE: NO, PLEASE SEE NOTE ABOVE AS DOORS ARE NOT | | | SHOWN ON LAYER AS PRINTED FOR FIRST FLR. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 110.26 FOR MIN DOOR(S) REQUIRED FOR MAIN | | | ELECTRICAL ROOM. PLEASE SEE ONE MAIN/EQUIPMENT LOCATED | | | DIRECTLY IN-FRONT OF THE EGRESS PATH/DOOR. PLEASE SEE | | | PANIC HARDWARE SHALL BE REQUIRED AND DOORS MUST OPEN IN | | | THE DIRECTION OF TRAVEL. PLEASE PROVIDE A NOTE ON PLANS | | | FOR THIS. | | | A NOTE ON E4.00 STATES "DOOR NEEDS TO BE RELOCATED", | | | HOWEVER THIS WAS NOT DONE AND IS SHOWN THE SAME IN | | | A-SHEETS AND E-SHEETS. | | | PLEASE ADD NOTE(S) TO PLANS FOR ALL CLEARANCES PER | | | 110.26 SHALL BE MET. | | | 4.00 ETC | | | | | | 7) NOTE: OK. | | | | | | 8) NOTE: NO, SAME NOTE, A BATTERY BACK UP FIXTURE IN | | | STAIRS WILL BE REQUIRED MIN AT EVERY OTHER LANDING. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE NFPA-72 WHICH REQUIRES BATTERY BACK UP | | | FIXTURES IN STAIR TOWERS AND OTHER AREAS WHERE EM LTS | | | ARE REQUIRED FOR MIN EGRESS PATHS. | | | PLEASE SEE 7.9.2.2 WHICH STATES NO SINGLE MEANS OF OVER | | | CURRENT PROTECTION OR SWITCHING ETC SHALL LEAVE ANY | | | EGRESS PATHS IN TOTAL DARKNESS AS SHOWN ON PLANS. | | | PLEASE KNOW AS REQUIRED BY THE AHJ AND THE FIRE | | | MARSHAL'S OFFICE A BATTERY BACK-UP FIXTURE OF SOME SORT | | | WILL BE REQUIRED FOR THESE EGRESS PATHS TO ALLEVIATE | | | THE ABOVE. | | | | | | 9) NOTE: NO/YES, PLEASE PROVIDE THE STAIRS SEPARATELY; | | | THE CALCULATIONS SEEM TO FIGURE IN ALL OTHER AREAS. THE | | | STAIR MINIMUM LIGHTING LEVELS ARE THE MOST IMPORTANT. | | | | | | ** PREVIOUS REVIEW NOTE **PLEASE PROVIDE COMPLETE | | | PHOTO-METRICS FORALL STAIR-TOWERS AND EGRESS PATHS. | | | PLEASE SEE LS 101 7.8.1.3 WHICH REQUIRES A MINIMUM OF | | | 10FT/CANDLES (108 LUX) FOR STAIR TOWERS UNDER NORMAL | | | CONDITIONS AND A MIN OF 1FT/CD UNDER EMERGENCY | | | CONDITIONS. | | | 7.9.2.2 | | | | | | 10) NOTE: OK, HOWEVER PLEASE KNOW FIXTURE TYPE FOR | | | STAIR TOWERS WILL BE REVISED. | | | | | | 11) NOTE: OK. | | | | | | 12) NOTE: NO, COULD NOT LOCATE IN PACKAGE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SUBMIT A LETTER FROM THE | | | FLORIDA POWER AND LIGHT REPRESENTATIVE ON THE | | | ACCEPTANCE OF FPL VAULT AS SHOWN. | | | | | | 13) NOTE:NO, PLEASE SEE THERE ARE STILL SOME COMMON | | | AREAS WHICH ARE MISSING CIRCUITING AND SOME MINOR | | | CIRCUITS IN UNITS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE COMPLETE PLANS WITH ALL CIRCUITING AND CORRELATE | | | WITH SUBMITTED PANEL SCHEDULES. REVIEW FOR CODE | | | COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | PLEASE BE SURE TO SEE 210.52B1,210.52D,210.11C3 ETC. | | | | | | 14) NOTE:NO, PLEASE SEE SOME HEAT STRIP UNITS ARE NOT | | | INDICATING THIS. PLEASE SEE SOME OF THESE ARE SHOWN | | | ABOVE THE NORMAL? | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 424.3B WHICH REQUIRES OCP FOR AHU/HEAT TO BE | | | SIZED AT A MIN OF 125%. PLEASE SEE SOME OCP AS | | | INDICATED WILL NEED TO BE ADJUSTED. | | | ** PLEASE BE SURE TO ADJUST AND CONDUCTOR SIZES AS | | | NEEDED. PER 310.16,240.4 ETC | | | | | | 15) NOTE: OK. | | | | | | 16) NOTE: OK, HOWEVER SEE NEW NOTES WITH RESPECT TO | | | PANEL SCHEDULES NOW THAT ROOMS AND AREAS ARE SHOWN. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PLACE ALL AREA AND ROOM DESIGNATIONS ON PLANS. | | | PLEASE SEE PREVIOUS COMMENTS WITH RESPECT TO COMPLIANCE | | | WITH CIRCUITING. | | | | | | 17) NOTE: OK. | | | | | | 18) NOTE: NO,/ OK, PLEASE SEE THE DETECTORS ARE NOW | | | SHOWN HOWEVER AS THESE ACT ON A INDIVIDUAL UNIT BASIS, | | | PLEASE SEE NFPA-72 DEFINITIONS AS SMOKE DETECTORS DO | | | ONLY THAT, DETECT. PLEASE ADJUST NOTES TO READ AS SMOKE | | | ALARMS AS THESE ARE DEVICES WHICH ACTUALLY DETECT AND | | | SOUND AN ALARM WHICH IS WHAT IS BEING STATED IN THE | | | NOTES. | | | PLEASE ALSO SEE 11.8.3. AS INSTALLATION ALSO INCLUDES | | | ANY DEVICES WITHIN 20FT OF COOKING APPLIANCES WHICH | | | REQUIRE A DIFFERENT TYPE OF DEVICE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE NFPA-72 11.8.3.5, 11.5.1.1 FOR SMOKE | | | DETECTORS REQUIRED INSIDE AND OUTSIDE ALL SLEEPING | | | RMS. | | | PLEASE SEE UNIT D1, PLEASE ALSO SEE OTHER UNITS WHERE | | | SD'S DO NOT APPEAR TO BE "OUTSIDE" SLEEPING AREAS OR | | | CORRIDORS. PLEASE SEE A DOOR SEPARATES BEDRM HALLWAYS | | | FROMLIVING/COMMON AREA OF UNIT. THIS SEEMS TO SHOW | | | NO SD COVERAGE FOR AREAS OUTSIDE BEDROOMS. PLEASE FIRE | | | REVIEW COMMENTS. | | | ** PLEASE PLACE NOTE ON PLANS WITH REFERENCE TO THE MIN | | | PLACEMENT REQUIREMENTS OF ABOVE NFPA. PLEASE SEE THAT | | | SD'S ARE LOCATED A MIN OF 3' FROM BATH, KITCHEN DOORS, | | | 3' FROM SUPPLY REGISTERS, ETC: WITH EXCEPTIONS AS | | | LISTED FOR LOCATIONS WITHIN 20' OF COOKING APPLIANCES. | | | ** PLEASE SEE SPECS/LISTING FROM SD MANUFACTURE AS MANY | | | REQUIRED SD'S TO BE FURTHER THAN LISTED ABOVE AND MOST | | | REQUIRED SD'S TO BE 5' FROM THE RETURN AIR GRILLE. | | | ** PLEASE KNOW, ANY CEILING HEIGHT VARIATIONS MAY | | | CHANGE LOCATION OF SD'S, AS THEY ARE REQUIRED TO BE | | | LOCATED WITHIN 12" OF THE HIGHEST POINT OF A FLAT | | | CEILING. | | | | | | 19) NOTE: OK. | | | | | | 20) NOTE: OK, SEEM TO BE OK.. | | | | | | 21) NOTE: OK. | | | | | | 22) NOTE: OK, HOWEVER SEE NOTE FOR FIRST FLR AREA IN | | | NEW NOTE. | | | | | | 23) NOTE:NO, PLEASE SEE 3RD FLOOR. ALSO SEE OTHER | | | NOTES. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CORRELATE ELECTRICAL ROOMS AND RISER DIAGRAM. | | | PLEASE SEE E4.0 SHOWS ELECTRICAL RM ON EVERY FLR, | | | HOWEVER RISER DOES NOT. | | | PLEASE SEE OTHER COMMENTS WITH RESPECT TO ELECTRICAL | | | RMS. | | | 215.5 | | | | | | 24) NOTE: OK. | | | | | | 25) NOTE: NO, PLEASE SEE ONE STILL SHOWN AS 2500A'S AND | | | THE OTHER 3200A'S. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CORRELATE MAIN ELECTRICAL ROOM EQUIPMENT WITH | | | RISER DIAGRAM. PLEASE SEE ONE SHOWS 3000A MAIN, THE | | | OTHER 4000A, PLEASE SEE ELECTRICAL PANELS SHOWN ON 4.00 | | | ALSO DO NOT CORRELATE WITH RISER. | | | PLEASE SEE MANY OF THESE ITEMS/LOCATIONS WERE REDLINED | | | ON ONE SET. | | | | | | 26) NOTE: NO, SEE 3RD FLR. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE METER CENTERS ON ELECTRICAL ROOMS SHOWN ON | | | E4.00 DO NOT CORRESPOND TO THE METER CENTERS ON 5.02 | | | | | | 27) NOTE: OK. | | | | | | 28) NOTE: OK. | | | | | | 29) NOTE:NO, PLEASE SEE LETTER RESPONSE MENTIONS THIS | | | IS IN PHASE ONE PLANS, HOWEVER THIS BUILDING OF PHASE | | | II IS BEING DONE UNDER ITS OWN RECORD AND SHALL | | | INDICATE ALL INFORMATION PERTINENT TO THE DESIGN, LIFE | | | SAFETY OF CONDUCTORS OVER CURRENT PROTECTION ETC. | | | PLEASE SEE RESPONSE LETTER MENTIONS OCP IS AT 800A'S?, | | | HOWEVER PLEASE SEE THE FEEDERS AS SHOWN ON THIS RISER | | | ONLY INDICATE CONDUCTORS RATED FOR 680A'S. PLEASE SEE | | | 240.4B, AND 240.6. AS THE FEEDERS ARE ONLY RATED AT | | | 680A'S AND THE LOAD ITSELF SHOWN IS 708A'S, PLEASE MAKE | | | NEEDED ADJUSTMENTS WITH THE CONDUCTORS AS SHOWN. | | | 310.16, 110.14 | | | PLEASE STILL BE SURE TO CORRELATE ALL WITH THE PHASE I | | | ENGINEERING DESIGN TEAM. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE OCP LOCATED AT GENERATOR WHICH IS PART | | | OF THE PHASE 1 HIGH-RISE BLDG. | | | PLEASE SEE EQUIPMENT SPECS INDICATE THE | | | GEN AT 1000KW. | | | 215.5 | | | | | | 30) NOTE: OK, HOWEVER NOTES FOR SIGNAGE NOT SHOWN. | | | PLEASE ALSO SEE RISER SHOWS EDPH2 AND MCB, YET EDPH2 IS | | | BEING SHOWN AS MLO ON PANEL SCHEDULE. | | | PLEASE SEE NEW NOTES WITH RESPECT TO THE LOCATION OF | | | SUCH EQUIPMENT. | | | | | | ** PREVIOUS REVIEW NOTE **] | | | PLEASE PROVIDE A MEANS OF DISCONNECT FOR THE FEEDERS | | | COMING FROM | | | GEN.225.31-225.39 | | | PLEASE SEE A MAIN CIRCUIT BRKR LOCATED IN EDPH2 WOULD | | | BE ACCEPTABLE. | | | SHALL ALSO REQUIRE SIGNAGE. | | | 230.2E,700.8 ETC. | | | | | | 31) NOTE:NO, PLEASE SEE PLANS AND CIRCUITS IN THIS | | | BUILDING STILL INDICATE ELECTRICAL BEING IN THIS | | | BUILDING FROM A PANEL IN THE PHASE I BUILDING WHICH IS | | | NOT AND WILL NOT BE PERMITTED. THESE ARE SEPARATE | | | BUILDINGS AND NO ELECTRICAL IN THIS PHASE II BLDG MAY | | | BE FED FROM THE PHASE II. | | | PLEASE SEE FBC DEFINITIONS OF BUILDINGS, WHICH WOULD | | | REQUIRE A FIREWALL, PLEASE SEE FIREWALL DEFINITION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PANEL "GH" AS SHOWN ON RISER WHICH IS SHOWN | | | FROM ANOTHER BLDG AND ANOTHER SERVICE, MAY NOT BE | | | LOCATED IN THIS BLDG.230.3 | | | *****PLEASE KNOW AS CONDITION SET FORTH BY THE DESIGN | | | TEAM ON PHASE ONE, A COMPLETE SEPARATION OF ALL | | | ELECTRICAL SYSTEMS WILL TAKE PLACE AND A COMPLETE 4 HR | | | SEPARATION WILL BE PROVIDED BETWEEN PARKING GARAGE AND | | | PHASE II HIGH RISER BLDG. PLANS DO NOT SEEM TO | | | CORRELATE WITH THIS. PLEASE KNOW, GARAGE IS NOW SHOWING | | | ELECTRICAL DEVICES/SYSTEMS FED FROM TWO SEPARATE | | | SERVICES WHICH WILL NOT BE PERMIT. A DEFINITIVE | | | SEPARATION WILL BE PROVIDED AND CROSSING OVER OF | | | SYSTEMS WILL NOT BE ACCEPTABLE. | | | 230.2, 230.3 ETC, 90.4 | | | | | | 32) NOTE: OK. | | | | | | 33) NOTE: OK. | | | | | | 34) NOTE: NO/, PLEASE SEE RISER OF THE 3/0 SHALL EXTEND | | | THROUGH OUT BUILDING. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE A COMPLETE GROUNDING ELECTRODE RISER IN | | | BLDG AND PROVIDE THIS LINE DIAGRAM ON ELECTRICAL RISER. | | | THIS SHOULD INCLUDE ALL GROUNDING FOR | | | TRANSFORMER(S)/SEPARATELY DERIVED SYSTEMS.250.58 | | | | | | 35) NOTE: OK. | | | | | | 36) NOTE:NO, THE LOADS SHOWN AS CONNECTED LOADS ON | | | PANELS ARE NOT THE LOAD CALCULATIONS NEEDED FOR ALL | | | MAINS AND BUILDING SERVICES AS SHOWN. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE NO LOAD CALCULATIONS WERE SUBMITTED FOR | | | MAINS, SERVICES, METER CENTERS ETC. MC1? | | | PLEASE SEE SOME CONNECTED LOADS DO NOT INDICATE LOADS | | | AND HOW THEY WERE DERIVED? | | | PLEASE KNOW VERIFICATION OF CODE COMPLIANCE FOR SERVICE | | | SIZES, FEEDERS, | | | SEC'S ETC CAN NOT BE VERIFIED OR REVIEWED AT THIS | | | TIME. | | | 310.16.240.4, 220, 215.5 | | | PLEASE BE SURE ALL CONTINUOUS LOADS ARE SHOWN AND | | | FIGURED AT 125%, | | | 215.3, 230.42 ETC. | | | | | | 37) NOTE: NO, NOT SUBMITTED, PLEASE KNOW THIS IS | | | REQUIRED AT THIS TIME IF PERMIT IS GOING TO BE ISSUED. | | | PLEASE KNOW, ANY MANUFACTURE CAN BE CHOSEN WHICH MEETS | | | THE SIZES AND LISTINGS AS NEEDED. PLEASE KNOW AT ANY | | | TIME AT A LATER DATE THIS MAY BE REVISED. | | | 90.7, 110.3 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE VERIFY AND SUBMIT SPECS FOR BUS-DUCT AS LOCAL | | | AMENDMENT DOES NOT PERMIT ALUM AS THE EQUIPMENT | | | GROUNDING METHOD. 250.62 SEE PREVIOUS NOTES. | | | | | | 38) NOTE: NO, SAME NOTE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE SPEC BOOKS SUBMITTED ARE FOR EQUIPMENT AND | | | SPEC BOOK FOR JOB-SITE WAS NOT SUBMITTED AT THIS TIME. | | | PLEASE SEE SOME OF THE ABOVE COMMENTS WHICH MAY AFFECT | | | PAGES IN THE JOB-SITE SPEC BOOKS. THESE SHOULD BE | | | REVIEWED AND MAKE ANY CHANGES AS NEEDED. | | | | | | 39) NOTE: OK, THE MAINS HAVE NOW BEEN DECREASED FROM | | | 1000A?S DOWN TO 800A?S; HOWEVER AS LOAD CALCULATIONS | | | HAVE NOT YET BEEN SUBMITTED FOR ALL, THIS IS YET TO BE | | | VERIFIED FULLY. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 230.95, 240.13 WHICH REQUIRES GROUND FAULT | | | PROTECTION FOR SYSTEMS WITH A VOLTAGE MORE THEN 150V TO | | | GROUND AND OVER 1000A'S. | | | PLEASE SEE "MSBH2. | | | | | | 40) NOTE: OK, 4-POLE SHOWN.. | | | | | | 41) NOTE:NO, NOT VERIFIED AT THIS TIME. RESPONSE | | | MENTIONS PART OF PHASE I WHICH IS KNOW, HOWEVER AS THIS | | | STATES THE FIRE PUMP IS NOW DIESEL AND THE SPECS | | | SUBMITTED ARE FOR AN ELECTRICAL FIRE PUMP, SOME | | | COORDINATION NEEDS TO TAKE PLACE WITH THE DESIGN TEAM | | | FROM PHASE I AND PLEASE KNOW AT THIS TIME CODE | | | COMPLIANCE WITH NFPA-20 FOR MINIMUM FUEL CONSUMPTION IF | | | INDEED DIESEL CAN NOT BE CONFIRMED. | | | 90.7, 110.3, NFPA-20, CHAPTERS 6, 7 AND 8, AT THIS TIME | | | THERE ARE TOO MANY SECTIONS TO LIST WHEN INFORMATION | | | PROVIDED DOES NOT CORRELATE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING FIRE PUMP AND EQUIPMENT NOT | | | INDICATED ON RISER DIAGRAM. | | | PLEASE SEE 695.4B1 FOR OCP REQUIRED FOR LOCKED ROTOR. | | | PLEASE ALSO SEE NFPA-20 FOR ELECTRICAL REQUIREMENTS FOR | | | MEANS-OF DISCONNECT LOCATION ETC. PLEASE SEE SPECS | | | SUBMITTED APPEAR TO SHOW THIS, HOWEVER NONE OF THESE | | | ITEMS ARE SHOWN ON RISER. UNABLE TO VERIFY CODE | | | COMPLIANCE FOR FIRE PUMP, FIRE PUMP CONTROLLER, | | | FEEDERS, SEC'S ETC. | | | ** PLEASE SEE SPECS WHICH CONTAIN THE TITLE FROM STEVEN | | | FELLER'S OFFICE INDICATE THE PUMP AS 277/480V, 125HP. | | | 215.5 | | | | | | 42) NOTE: NO, PLEASE SEE RISER AND SCHEDULE STILL DO | | | NOT CORRELATE. | | | PLEASE SEE "ERL2", PLEASE SEE RISER 45KVA AND PANEL | | | SHOWS 30 ETC. | | | PLEASE SEE THE MAXIMUM OCP FOR THE 112 KVA TRANSFORMERS | | | SHALL BE SIZED PER 450.3. (125%). PLEASE SEE ONLY IF | | | MEETING ALL THE EXCEPTIONS, OCP CAN BE HIGHER THAN | | | 125% | | | **PLEASE ALSO SEE NEW NOTES DUE TO PLANS AND CHANGES | | | AND PANEL SCHEDULES SUBMITTED. | | | | | | | | | **PLEASE CORRELATE ALL TRANSFORMERS WITH SCHEDULE(S). | | | PLEASE SEE 112.5?, 150? KVA | | | PLEASE ALSO CONFIRM KVA AS MAX OCP FOR TRANSFORMER MAY | | | NOT EXCEED 125% AS 450.3 | | | TABLES. | | | | | | 43) NOTE: OK. | | | | | | 44) NOTE: NO, PLEASE ONE OF THE PREVIOUS NOTES ABOVE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE THE COMPLETE GROUNDING ELECTRODE | | | SYSTEMS DETAIL PER | | | 250.50, 250.104, 250.64,,, | | | | | | 45) NOTE: OK, HOWEVER SEE NOTES AS NOTES ABOVE WITH | | | RESPECT TO THE MLO AND MCB BEING DIFFERENT ON PANEL AND | | | RISER. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE EDPH2 IS SHOWN AS | | | 1000A'S ON PANEL SCHEDULES AND SHOWN AS 800A ON RISER?? | | | PLEASE CORRELATE. | | | 215.5 | | | | | | 46 NOTE: OK, AS MSBE HAS NOW CHANGED TO 800A?S. | | | | | | 47)NOTE: OK, HOWEVER PLEASE KNOW, IF THIS INFORMATION | | | IS NOT SUBMITTED, SEPARATE PERMITS PLANS AND FEES WILL | | | BE REQUIRED BEFORE ANY SITE LIGHTING MAY BE INSTALLED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PANEL "SL" IS SHOWN AS HAVING "SITE | | | LIGHTING" HOWEVER, SITE LIGHTING COULD NOT BE LOCATED | | | ON ELECTRICAL PLANS? | | | IF SITE LIGHTING CONTAINS LT POLES, PLEASE SUBMIT WIND | | | LOAD CALCULATIONS FOR FBC 140MPH. THESE WILL BE | | | REVIEWED BY A STRUCTURAL REVIEWER. ** PLEASE BE SHOULD | | | POLE CONTAIN FIXTURES FOR CALCULATION PURPOSES. | | | | | | 48) NOTE: OK. | | | | | | 49) NOTE:NO, PLEASE SEE RISER SHOWS SOME ITEMS WHICH | | | ARE STILL NOT LISTED ON PANELS SCHEDULES. PLEASE SEE | | | 4EH2 TO 4EL2, MISSING ON PANEL SCHEDULE AND MISSING | | | TRANSFORMER INFORMATION ETC. CAN NOT BE VERIFIED AT | | | THIS TIME. | | | | | | ** PREVIOUS REVIEW NOTE ** PLEASE LABEL ALL | | | TRANSFORMERS ON RISER AS INDICATED ON PANEL SCHEDULES. | | | 215.5, 450, ETC | | | | | | 50) NOTE: OK. | | | | | | 51) NOTE:NO, PLEASE SEE NOTES WERE NOTED, HOWEVER | | | PLEASE PROVIDE THE DETAIL FOR TYPICAL. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE A DISCONNECT DETAIL INCLUDING SIZE ETC | | | FOR ROOF TOP UNITS. THIS MAY BE A "TYPICAL" DETAIL FOR | | | EACH SIZE IF NOT ALL THE SAME. | | | 215.5, 440.11 | | | | | | 52) NOTE: OK. | | | | | | 53) NOTE: NO, RESPONSE MENTIONS DEVICES HEIGHTS SHOWN | | | ON E0.00, HOWEVER THE HEIGHTS ON DEVICES ARE NOT THE | | | ONLY REQUIREMENTS FOR ELECTRICAL DEVICES. PLEASE LIST | | | NOTE AS PREVIOUSLY REQUESTED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FAIR HOUSING ACT | | | REGULATIONS, 24 CFR 100.205 WITH RESPECT TO THE | | | LOCATIONS OF "ALL" ELECTRICAL DEVICES, CONTROLS. | | | A NOTE IS LOCATED ON "GEN NOTES" WHICH MENTIONS THE | | | HEIGHTS FOR RECEPTS AND SWITCHES, HOWEVER THIS SHOULD | | | REFLECT | | | FHAR ETC AS NOTED ABOVE. | | | | | | 54) NOTE:NO? PLEASE KNOW AS THE PHASING OF THIS | | | PROJECT ANDHOW THIS IS BEING DONE AND HOW THE PLANS | | | HAVE BEEN SUBMITTED SHOWING PARTS OF PHASE II BEING FED | | | FROM PHASE I IS UNCLEAR. | | | THE EGRESS PATH SEEMS TO HAVE BEEN SHOWN, HOWEVER AS | | | THE BUILDING OF EACH PHASE IS NOT CLEAR, UNABLE TO | | | REVIEW FOR ACTUAL INSTALLATION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THE AMENITY DECK DETAILS COULD NOT BE | | | LOCATED IN SETS. | | | PLEASE SEE E2.06 WHICH ONLY SEEMS TO INDICATE A PARTIAL | | | AREA SHOWN. | | | PLEASE SEE NO ELECTRICAL SHOWN FOR LIGHTING ETC? | | | PLEASE SEE LS 101 7.8 AND 7.9 WHICH REQUIRE MEANS OF | | | EGRESS LIGHTING TO THE PUBLIC RIGHT OF WAY; THIS WOULD | | | INCLUDE EMERGENCY LIGHTING AS REQUIRED. | | | PLANS NOW SHOW A SEPARATE PHASE LINE, AS GARAGE WAS TO | | | BE BUILT WITH PHASE ONE BLDG AND DID NOT SHOW GARAGE | | | WITH PHASE LINE DOWN THE CENTER OF THE GARAGE. | | | | | | | | | ** NEW NOTES 2ND REVIEW *** | | | NOTES ARE BASED ON REVISIONS MADE TO PLANS AND | | | INFORMATION NOW SUBMITTED. PLEASE SEE ALSO NEW NOTES | | | WHICH WERE NOT COMMENTED ON THE PREVIOUS REVIEW #63 AND | | | 64 AS THIS WAS NOT PART OF THE ELECTRICAL REVIEW. | | | | | | 55) NOTE: PLEASE SEE MSBH2 IS MISSING | | | CONDUCTORS/FEEDERS FOR H-2 AND SL1. | | | 310.16, 240.4,215.5 ETC | | | | | | 56)NOTE: PLEASE SEE MSBH2 PANEL SCHEDULE FOR OCP | | | DEVICES FOR EACH PANEL BEING SERVED DOES NOT CORRELATE | | | WITH THE OCP DEVICES SHOWN ON RISER. PLEASE ALSO | | | CORRELATE CONDUCTORS/FEEDERS. | | | 408.4, 310.16, 240.4 | | | | | | 57) NOTE: PLEASE SEE FEEDERS ON THE SECONDARY SIDE FOR | | | RL2 SHOW #6'S WHICH TERMINATE IN 100A OCP. PLEASE SEE | | | 240.21C, 408.16, 310.16 ETC, | | | PLEASE SEE THE LOAD ON THIS PANEL EXCEEDS THAT OF THE | | | RATING OF THE #6'S IN EITHER CASE. | | | | | | 58) NOTE: PLEASE SEE PANEL SCHEDULE FOR MSBH2 WHICH | | | SHOWS 400A OCP FEEDING PANEL H2 WHICH IS ONLY RATED AT | | | 225A'S? PLEASE SEE CONDUCTORS ON PANEL SCHEDULE ARE | | | MISSING HOWEVER SHOWN ON RISER. | | | 240.4, 408, ETC | | | | | | 59) NOTE: PLEASE SEE RISER SHOWS FPL SERVICE | | | TRANSFORMER BEING 120/208V , YET THIS IS BEING SHOWN | | | FEEDING 277/480V SYSTEMS?? | | | | | | 60) NOTE: PLEASE SEE PANEL SCHEDULES FOR UNITS INDICATE | | | A 1-POLE BREAKER FEEDING EACH OF THE DISHWASHER AND | | | DISPOSAL RECEPTACLE, HOWEVER PLEASE SEE 210.4B AS THIS | | | WOULD BE REQUIRED TO BE A 2-POLE BRKR IF FEEDING A | | | DEVICE ON SAME YOKE. | | | | | | 61) NOTE: PLEASE SEE FBC 2001 CHAPTER 13, THE ENERGY | | | CALCULATIONS SUBMITTED ARE NOT SIGNED, DATED OR SEALED | | | BY THE RESPONSIBLE DESIGN PROFESSIONAL. | | | FS 471.025, FAC 61G15-23.002 | | | | | | 62) NOTE: PLEASE SEE FIRE SPRINKLER SHEETS ARE BEING | | | SEALED WITH A SEAL AND STAMP WHICH IS NOT PERMITTED | | | (RUBBER STAMP) AND SEAL WHICH IS NO LONGER VALID WITH | | | THE STATE. PLEASE SEE RULING IN THE FAC 61G15-23.001 | | | WHICH REQUIRED ALL ENGINEERS TO OBTAIN THEIR NEW SEALS | | | WITH THE WORDING OF "LICENSE" AND "CERTIFICATE" WAS NOT | | | LONGER PERMITTED. THIS RULE WAS PAST IN 2/04, HOWEVER | | | AN EXTENSION WAS GRANTED TO 12/31/05 ONLY. | | | | | | 63) NOTE: PLEASE SEE FPL VAULT IS SHOWING A STROBE | | | DEVICE FROM THE BUILDINGS FA SYSTEM WHICH IS NOT | | | PERMITTED. NO EQUIPMENT OR ELECTRICAL DEVICES OF ANY | | | KIND ARE PERMITTED IN THE FPL VAULT. | | | | | | 64) NOTE:PLEASE SEE ALL AUDIBLE AND VISUAL DEVICES | | | FOR FA SYSTEMS ARE REQUIRED TO MEET FBC 2001, | | | 11-4.28.1, PLEASE LIST AND SHOW COMPLIANCE FOR | | | 11-4.28.2 AND 11-4.28.3(4). PLEASE SEE THERE ARE MANY | | | LOCATIONS FOR MIN CANDELAS DO NOT SEEM TO HAVE BEEN | | | MET. | | | | | | 65) NOTE: PLEASE SEE E2.01, PLEASE SEE AREAS AND WALL | | | OUTSIDE UNIT A3, WHICH DO NOT SEEM TO BE COMPLETE? | | | PLEASE CLARIFY HOW ACCESS TO THE FIRE COMMAND ROOM WILL | | | TAKE PLACE, COULD NOT LOCATE ANY DOORS ON THIS SHEET | | | FOR THIS?? | | | | | | 66) NOTE: PLEASE BE SURE TO GO BACK AND CHECK ALL | | | KITCHEN COUNTER SPACES PER 210.52C1, E-2, G1A, ETC. | | | | | | 67) NOTE: PLEASE SEE NOW THAT ROOM AND AREA | | | DESIGNATIONS ARE PLACES ON PLANS, PLEASE REVISE PANEL | | | SCHEDULES FOR UNITS TO CORRELATE WITH THESE ROOMS AND | | | AREAS. INSTEAD OF GEN LTS, GEN RECEPTS, IT WOULD | | | MENTION: BEDRM, #2 LTS, MASTER BDRM RECEPTS ETC. | | | 408.4. | | | | | | 68) NOTE: PLEASE SEE NFPA-110 7.2.2.1. TRANSFER | | | SWITCHES SHALL BE PERMITTED TO BE INSTALLED IN THE | | | NORMAL ELECTRICAL SERVICE ROOM WHERE TWICE THE | | | CLEARANCE REQUIRED BY ARTICLE 110.26(A) OF NFPA 70, | | | NATIONAL ELECTRICAL CODE, EXISTS BETWEEN EQUIPMENT | | | ENCLOSURES. | | | PLEASE ADJUST ROOM AS NEEDED AND REQUIRED. | | | | | | | | | | | | ** NOTE: PLEASE SEE MANY OF THE ABOVE ITEMS WERE | | | REDLINED ON ONE SET FOR AREAS OF NOTES ABOVE. | | | | | | ** NOTE: PLEASE SEE POSSIBLE NOTES FROM OTHER | | | REVIEWER(S) WHICH MAY AFFECT ELECTRICAL PLANS AND | | | DESIGN. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | 2006-11-05 11:30:44 | REVIEW IN PROGRESS | | 2006-08-23 00:00:00 | REVIEW STOPPED ON 8/23 , PLANS WILL GO | | | INTO "F" STATUS ONCE REVIEW IS | | | COMPLETED. | | | NOTES WILL FOLLOW. | | 2006-08-22 00:00:00 | REVIEW IN PROGRESS | | 2006-08-20 00:00:00 | ** ONE ROLL OF MEP, FP IN ELECTRICAL | | | FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2006-02-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-02 |
Time |
20:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-24 |
Time |
19:03 |
Sent To |
|
|
| Notes |
| 2006-01-27 00:00:00 | **** THE EDGE PHASE II ** 17 STORY ** | | | | | | ********** UNSAT *************** | | | | | | ** PLEASE KNOW, PLANS ARE NOT COMPLETE | | | AND REVIEW BELOW IS BASED ON PLANS | | | SUBMITTED. | | | PLEASE ALSO KNOW, SINCE PLANS ARE NOT | | | COMPLETE, THERE MAY OR MAY NOT BE | | | FURTHER COMMENTS ON NEXT REVIEW. | | | | | | | | | 1)NOTE: PLEASE SEE ADDRESSING NEEDS TO | | | BE ADDRESSED AS PERMIT APPLICATION | | | MENTIONS 350 S AUST, PCN USED ON | | | APPLICATION IS FORRR 300 S AUST. | | | PLEASE ALSO SEE PLANS INDICATE 300 S | | | AUSTRALIAN AVE. | | | PLEASE BE SUREADDRESS IS CORRECTED | | | WITH THE ADDRESSING DEPT AND ADJUST | | | PLANS IF NEEDED. | | | | | | 2)NOTE: PLEASE SEE MISSING LICENSE | | | INFORMATION REQUIRED ON TITLE BLOCKS FOR CONSULTING | | | ENGINEERING FIRM AS REQUIRED | | | UNDER FLORIDA STATUES 471.023, FLORIDA ADMINISTRATIVE | | | CODE 61G15-23.002. | | | PLEASE SEE COMPANIES AS LISTED ARE | | | PROVIDING ENGINEERING SERVICES" AND NO | | | CERTIFICATE OF AUTHORIZATION NUMBER | | | COULD BE LOCATED ON STATE WEBSITE OF | | | DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION. | | | (DBPR). | | | PLEASE KNOW AS REQUIRED BY THESAID | | | FLORIDA STATUES AND LICENSINGUNDER FS | | | 468 FOR THIS OFFICE, ONE SET OF MEP | | | PLANS ARE BEING RETAINED AND SHALL BE | | | FORWARDED TO THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS FOR REVIEW OF | | | SAID REQUIREMENTS. WE HAVE CONSULTED | | | WITH THEFBPE'S ON THE ABOVE. PLEASE | | | CONTACT MR. JERRY ONGLEY AND MR. DOUGLAS | | | SUNSHINE IF THERE ARE ANY QUESTIONS. | | | ** PLEASE KNOW, THESE REQUIREMENTS ARE | | | ALSOFOR THE OTHER CONSULTING COMPANIES | | | AS LISTED ON SAID TITLE BLOCKS. | | | | | | 3)NOTE: PLEASE SEE SPECS SUBMITTED FOR | | | FIRE PUMP CONTAIN THE TITLE AND THE | | | RESPONSIBLE ENGINEER AS STEVEN FELLER OF | | | FELLER ENGINEERING. STEVEN FELLER AND | | | FELLER ENGINEERING IS THE CONSULTING | | | ENGINEERS OF PHASE-ONE. | | | PLEASE CORRECT ALL SUBMITTALS FOR FIRE | | | PUMP, FIRE PUMP CONTROLLER ETC. | | | | | | 4)NOTE: PLEASE BE SURE PLANS REFERENCE | | | ALL CURRENT CODE IN EFFECT FOR THIS | | | PROJECT. PLEASE KNOW WE ARE CURRENTLY | | | UNDER THE 2003 NFPA-101, 2002 NFPA-72 | | | AND 2002 NFPA-70 ETC. | | | | | | 5)NOTE: PLEASE KNOW, ENTRANCE TO MAIN | | | ELECTRICAL ROOM SHALL BE DETERMINED BY | | | THIS OFFICE AND FIRE MARSHAL'S OFFICE | | | FOR ACCESSIBILITY. PLANS INDICATE ACCESS | | | GRANTED THROUGH GARAGE AREA AND TRAVEL | | | DISTANCE IN BLDG MAY REQUIRED A MORE | | | ACCESSIBLE MEANS TO MAIN ELECTRICAL | | | ROOM. | | | ** PLEASE SEE POSSIBLE FIRE REVIEW | | | COMMENTS. | | | | | | 6)NOTE: PLEASE SEE 110.26 FOR MIN | | | DOOR(S) REQUIRED FOR MAIN ELECTRICAL | | | ROOM. PLEASE SEE ONE MAIN/EQUIPMENT | | | LOCATED DIRECTLY IN-FRONT OF THE EGRESS | | | PATH/DOOR. | | | PLEASE SEE PANIC HARDWARE SHALL BE | | | REQUIRED AND DOORS MUST OPEN IN THE | | | DIRECTION OF TRAVEL.PLEASE PROVIDE A | | | NOTE ON PLANS FOR THIS. | | | A NOTE ON E4.00 STATES "DOOR NEEDS TO BE RELOCATED" , | | | HOWEVER THIS WAS NOT DONE | | | AND IS SHOWN THE SAME IN A-SHEETS AND | | | E-SHEETS. | | | PLEASE ADD NOTE(S) TO PLANS FOR ALL | | | CLEARANCES PER 110.26 SHALL BE MET. | | | 4.00 ETC | | | | | | 7)NOTE: PLEASE VERIFY WHERE LIGHTING IS | | | FOR ELECTRICAL RMS ON FLRS | | | 2,5,6,7,10,16? | | | 215.5, LS1017.8,7.9 ETC | | | | | | 8)NOTE: PLEASE SEENFPA-72 WHICH | | | REQUIRES BATTERY BACK UP FIXTURES IN | | | STAIR TOWERS AND OTHER AREAS WHERE EM | | | LTS ARE REQUIRED FOR MIN EGRESS PATHS. | | | PLEASE SEE 7.9.2.2 WHICH STATES NO | | | SINGLE MEANS OF OVERCURRENT PROTECTION | | | OR SWITCHING ETC SHALL LEAVE ANY EGRESS | | | PATHS IN TOTAL DARKNESS AS SHOWN ON | | | PLANS. | | | PLEASE KNOW AS REQUIRED BY THE AHJ AND | | | THE FIRE MARSHAL'S OFFICE A BATTERY | | | BACK-UP FIXTURE OF SOME SORT WILL BE | | | REQUIRED FOR THESE EGRESS PATHS TO | | | ALLEVIATE THE ABOVE. | | | | | | 9)NOTE: PLEASE PROVIDE COMPLETE | | | PHOTO-METRICS FOR FOR ALL STAIR-TOWERS | | | AND EGRESS PATHS. PLEASE SEE LS 101 | | | 7.8.1.3 WHICH REQUIRES A MIN OF | | | 10FT/CANDLES (108 LUX) FOR STAIR TOWERS | | | UNDER NORMAL CONDITIONS AND A MIN OF | | | 1FT/CD UNDER EMERGENCY CONDITIONS. | | | 7.9.2.2 | | | | | | 10)NOTE: PLEASE INDICATE BY SOME MEANS | | | THE IDENTIFICATION OF ALL LIGHTING | | | FIXTURES ON PLANS. PLEASE SEE LIGHTING | | | IN STAIRS, TYPE OF FIXTURE COULD NOT BE | | | FOUND AND CORRELATION TO THE SUBMITTED | | | FIXTURE SCHEDULE COULD NOT BE DONE. | | | | | | 11)NOTE: PLEASE PROVIDE A NOTE ON ROOF | | | PLANS: | | | " ALL PROPOSED LIGHTNING PROTECTION | | | SYSTEMS SHALL MEET NFPA-780" OR WORDS TO | | | THAT AFFECT. | | | ** PLEASE KNOW, THERE ARE MANY "LIGHTING PREVENTION | | | SYSTEMS" ON THE MARKET WHICH | | | ARE NOT ACCEPTABLE IN THIS JURISDICTION | | | OR BY NFPA. | | | | | | 12)NOTE: PLEASE SUBMIT A LETTER FROM THE | | | FLORIDA POWER AND LIGHT REPRESENTATIVE | | | ON THE ACCEPTANCE OF FPL VAULT AS SHOWN. | | | | | | 13)NOTE: PLEASE COMPLETE PLANS WITH ALL | | | CIRCUITINGAND CORRELATE WITH SUBMITTED | | | PANEL SCHEDULES. REVIEW FOR CODE | | | COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | PLEASE BE SURE TO SEE | | | 210.52B1,210.52D,210.11C3 ETC. | | | | | | 14)NOTE: PLEASE SEE 424.3B WHICH | | | REQUIRES OCP FOR AHU/HEAT TO BE SIZED AT | | | A MIN OF 125%. PLEASE SEE SOME OCP AS | | | INDICATED WILL NEED TO BE ADJUSTED.** | | | PLEASE BE SURE TO ADJUST AND CONDUCTOR | | | SIZES AS NEEDED. PER 310.16,240.4 ETC | | | | | | 15)NOTE: PLEASE SEE 210.52D,210.11C3 FOR | | | BATH RECEPTS. PLEASE SEE SOME UNITS , | | | B2, B1 ETC. | | | | | | 16)NOTE: PLEASE PLACE ALL AREA AND ROOM DESIGNATIONS ON | | | PLANS. | | | PLEASE SEE PREVIOUS COMMENTS WITH | | | RESPECT TO COMPLIANCE WITH CIRCUITING. | | | | | | 17)NOTE: PLEASE INDICATE THE KITCHEN | | | CIRCUITS AS SMALL APPLIANCE. | | | 210.52B | | | | | | 18)NOTE: PLEASE SEE NFPA-72 11.8.3.5, | | | 11.5.1.1 FOR SMOKE DETECTORS REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPINGRMS. | | | PLEASE SEE UNIT D1, PLEASE ALSO SEE | | | OTHER UNITS WHERE SD'S DO NOT APPEAR TO | | | BE "OUTSIDE" SLEEPING AREAS OR | | | CORRIDORS. PLEASE SEE A DOOR SEPARATES | | | BEDRM HALLWAYS FROM LIVING/COMMON AREA | | | OF UNIT. THIS SEEMS TO SHOW NO SD | | | COVERAGE FOR AREAS OUTSIDE BEDROOMS. | | | PLEASE FIRE REVIEW COMMENTS. | | | ** PLEASE PLACE NOTE ON PLANS WITH | | | REFERENCE TO THE MIN PLACEMENT | | | REQUIREMENTS OF ABOVE NFPA. PLEASE SEE | | | THAT SD'S ARE LOCATED A MIN OF 3' FROM BATH,KITCHEN | | | DOORS , 3' FROM SUPPLY | | | REGISTERS , ETC :WITH EXCEPTIONS AS | | | LISTED FOR LOCATIONS WITHIN 20' OF | | | COOKING APPLIANCES. | | | ** PLEASE SEE SPECS/LISTING FROM SD | | | MANUFACTURE AS MANY REQUIRED SD'S TO BE | | | FURTHER THAN LISTED ABOVE AND MOST | | | REQUIRED SD'S TO BE 5' FROM THE RETURN | | | AIR GRILLE. | | | ** PLEASE KNOW, ANY CEILING HEIGHT | | | VARIATIONS MAY CHANGE LOCATION OF SD'S, | | | AS THEY ARE REQUIRED TO BE LOCATED | | | WITHIN 12" OF THE HIGHEST POINT OF A | | | FLAT CEILING. | | | | | | 19)NOTE: PLEASE SHOW AND LABEL ALL | | | PANELS, ELECTRICAL AND PANELS WHICH | | | APPEAR TO BE LOW VOLTAGE? | | | PLEASE KNOW, ANY PLUG-IN TYPE | | | TRANSFORMERS MAY NOT BE LOCATED IN CLOSE | | | PROXIMITY OF EASILY IGNITABLE MATERIALS | | | IN CLOTHES CLOSETS. | | | PLEASE KNOWIN MANY LOCAL JURISDICTIONS | | | AS A RESULT OF THE HEATING OF THESE TYPE TRANSFORMER A | | | FIRE HAS OCCURRED. IN THE | | | INTEREST OF LIFE SAFETY AND PROPERTY | | | PLEASE ADJUST LOCATIONS. | | | 110.26,240.24D, 408.7 ETC. | | | PLEASE ALSO SEE UNIT(S) WHICH INDICATE A | | | PANEL OF SOME SORT "INSIDE " THE BATHTUB | | | LOCATION. PLEASE SEE 240.24 FOR | | | PERMITTEDLOCATIONS OF PANELS. | | | PLEASE SEE REDLINED PLANS. | | | PLEASE SEE UNIT "G" FOR WHAT APPEARS TO | | | BE TWO PANELS? | | | PLEASE SEE D2, PLEASE SEE A1, PANEL NOT | | | LOCATED ON WALL, SEE P3, P2 MISSING | | | PANEL. | | | PLEASE VERIFY ALL OF THE ABOVE AS MANY | | | OF THESE HAVE BEEN REDLINED ON ONE SET | | | OF PLANS. | | | | | | 20)NOTE: PLEASE SEE 210.52 FOR MISSING | | | RECEPTS FOR 2',6'AND 12 RULE. PLEASE SEE | | | SOME MISSING FOR 2' OF WALL SPACE. | | | | | | 21)NOTE: PLEASE SEE 210.52C2, 210.8A16 | | | FOR WHAT APPEARS TO BE SHOWN AS AN | | | ISLAND KITCHEN. B2 | | | | | | 22)NOTE: PLEASE SEE SEE UNIT UNIT A-2 | | | LAYOUT OF WALLS AND DOORS.PLEASE SEE | | | AREA WHERE THERE SEEMS TO BE A ROOM? | | | | | | 23)NOTE: PLEASE CORRELATE ELECTRICAL | | | ROOMS AND RISER DIAGRAM. PLEASE SEE E4.0 | | | SHOWS ELECTRICAL RM ON EVERY FLR, | | | HOWEVER RISER DOES NOT. | | | PLEASE SEE OTHER COMMENTS WITH RESPECT | | | TO ELECTRICAL RMS. | | | 215.5 | | | | | | 24)NOTE: PLEASE PROVIDE A CURB DETAIL | | | FOR FLR PENETRATIONS OF BUS-DUCT PER | | | 368.6 WHERE A VERTICAL RISER PENETRATES | | | TWO OR MORE DRY FLOORS, A MINIMUM 100 MM | | | (4 IN.) HIGH CURB SHALL BE INSTALLED | | | AROUND ALL FLOOR OPENINGS FOR RISER | | | BUSWAYS TO PREVENT LIQUIDS FROM ENTERING | | | THE OPENING. THE CURB SHALL BE INSTALLED | | | WITHIN 300 MM (12 IN.) OF THE FLOOR | | | OPENING. ELECTRICAL EQUIPMENT SHALL BE | | | LOCATED SO THAT IT WILL NOT BE DAMAGED | | | BY LIQUIDS THAT ARE RETAINED BY THE | | | CURB. | | | | | | 25)NOTE: PLEASE CORRELATE MAIN | | | ELECTRICAL ROOM EQUIPMENT WITH RISER | | | DIAGRAM. PLEASE SEE ONE SHOWS 3000A | | | MAIN, THEOTHER 4000A, PLEASE SEE | | | ELECTRICAL PANELSSHOWN ON 4.00 ALSO DO | | | NOT CORRELATE WITH RISER. | | | PLEASE SEE MANY OF THESE ITEMS/LOCATIONS | | | WERE REDLINED ON ONE SET. | | | | | | 26)NOTE: PLEASE SEE METER CENTERS ON | | | ELECTRICAL ROOMS SHOWN ON E4.00 DO NOT | | | CORRESPOND TO THE METER CENTERS ON 5.02 | | | 215.5 | | | | | | 27)NOTE: PLEASE SEE METER CENTER(S), | | | PLEASE SEE THERE ARE MANY UNIT | | | IDENTIFICATIONS WHICH DO NOT CORRELATE | | | TO THE UNITS ON PLANS. | | | PLEASE SEE UNITS TYPES ON RISER. | | | 215.5 | | | | | | 28)NOTE: PLEASE SEE RISER WHICH | | | INDICATES THE ELEVATOR'S ELECTRICAL | | | EQUIPMENT LOCATED ON FIRST FLR, HOWEVER | | | PLEASE SEE PLANS FOR ROOF AS ELEVATOR | | | EQUIPMENT ROOM IS SHOWN AT THAT | | | LOCATION. PLEASE CORRELATE. | | | 215.5 | | | | | | 29)NOTE: PLEASE PROVIDE OCP LOCATED AT | | | GENERATOR WHICH IS PART OF THE PHASE 1 | | | HIGH-RISE BLDG. | | | PLEASE SEE EQUIPMENT SPECS INDICATE THE | | | GEN AT 1000KW. | | | 215.5 | | | | | | 30)NOTE: PLEASE PROVIDE A MEANS OF | | | DISCONNECT FOR THE FEEDERS COMING FROM | | | GEN.225.31-225.39 | | | PLEASE SEE A MAIN CIRCUIT BRKR LOCATED | | | IN EDPH2 WOULD BE ACCEPTABLE. | | | SHALL ALSO REQUIRE SIGNAGE. | | | 230.2E,700.8 ETC. | | | | | | 31)NOTE: PLEASE SEE PANEL "GH" AS SHOWN | | | ON RISER WHICH IS SHOWN FROM ANOTHER | | | BLDG AND ANOTHER SERVICE, MAY NOT BE | | | LOCATED IN THIS BLDG.230.3 | | | *****PLEASE KNOW AS CONDITION SET FORTH | | | BY THE DESIGN TEAM ON PHASE ONE, A | | | COMPLETE SEPARATION OF ALL ELECTRICAL | | | SYSTEMS WILL TAKE PLACE AND A COMPLETE 4 | | | HR SEPARATION WILL BE PROVIDED BETWEEN | | | PARKING GARAGE AND PHASE II HIGH RISER | | | BLDG. PLANS DO NOT SEEM TO CORRELATE | | | WITH THIS. PLEASE KNOW, GARAGE IS NOW | | | SHOWING ELECTRICAL DEVICES/SYSTEMS FED | | | FROM TWO SEPARATE SERVICES WHICH WILL | | | NOT BE PERMIT. A DEFINITIVE SEPARATION | | | WILL BE PROVIDE AND CROSSING OVER OF | | | SYSTEMS WILL NOT BE ACCEPTABLE. | | | 230.2,230.3 ETC, 90.4 | | | | | | 32)NOTE: PLEASE PLACE NOT ON PLANS AS NO | | | EQUIPMENT GROUNDING CONDUCTORS MAY BE | | | ALUMINUM, AND NO FEEDERS SMALLER THAN | | | #2. PER CITY OF WEST PALM BEACH LOCAL | | | AMENDMENTS TO THE 2001 FBC.250.62,310.2 | | | | | | 33)NOTE: PLEASE PLACE NOTE ON PLANS FOR | | | COLOR CODING OF 277/480V SYSTEMS PER | | | LOCAL AMENDMENTS, 215.2 | | | BROWN, PURPLE, YELLOW. | | | ** PLEASE KNOW SPECIFIC COLOR CODING PER | | | 277/480V IS NOT PROVIDED IN THE NEC AND | | | ONLY A "HIGH-LEG" SHALL HAVE "ORANGE" AS | | | THE COLOR. | | | | | | 34)NOTE: PLEASE PROVIDE A COMPLETE | | | GROUNDING ELECTRODE RISER IN BLDG AND | | | PROVIDE THIS LINE DIAGRAM ON ELECTRICAL | | | RISER. THIS SHOULD INCLUDE ALL GROUNDING | | | FOR TRANSFORMER(S)/SEPARATELY DERIVED SYSTEMS.250.58 | | | | | | 35)NOTE: PLEASE INDICATE THE ATTACHMENT | | | FOR TRANSFORMERS AS SHOWN AS REQUIRED | | | PER ABOVE NOTE #34 AND 250.30, 250.66 | | | | | | 36)NOTE: PLEASE SEE NO LOAD CALCULATIONS | | | WERE SUBMITTED FOR MAINS, SERVICES, | | | METER CENTERS ETC. MC1? | | | PLEASE SEE SOME CONNECTED LOADS DO NOT | | | INDICATE LOADS AND HOW THEY WERE | | | DERIVED.? | | | PLEASE KNOW VERIFICATION OF CODE | | | COMPLIANCE FOR SERVICE SIZES, FEEDERS, | | | SEC'S ETC CAN NOT BE VERIFIED OR | | | REVIEWED AT THIS TIME. | | | 310.16.240.4,220, 215.5 | | | PLEASE BE SURE ALL CONTINUOUS LOADS ARE | | | SHOWN AND FIGURED AT 125%, | | | 215.3,230.42 ETC. | | | | | | 37)NOTE: PLEASE VERIFY AND SUBMIT SPECS | | | FO BUS-DUCT AS LOCAL AMENDMENT DOES NOT | | | PERMIT ALUM AS THE EQUIPMENT GROUNDING | | | METHOD. 250.62 SEE PREVIOUS NOTES. | | | | | | 38)NOTE: PLEASE SEE SPEC BOOKS SUBMITTED | | | ARE FOR EQUIPMENT AND SPEC BOOK FOR | | | JOB-SITE WAS NOT SUBMITTED AT THIS TIME. | | | PLEASE SEE SOME OF THE ABOVE COMMENTS | | | WHICH MAY AFFECT PAGES IN THE JOB-SITE | | | SPEC BOOKS. THESE SHOULD BE REVIEWED AND | | | MAKE ANY CHANGES AS NEEDED. | | | | | | 39)NOTE: PLEASE SEE 230.95,240.13 WHICH | | | REQUIRES GROUND FAULT PROTECTION FOR | | | SYSTEMS WITH A VOLTAGE MORE THEN 150V TO | | | GRND AND OVER 1000A'S. | | | PLEASE SEE "MSBH2. | | | | | | 40)NOTE: PLEASE VERIFY SIZING OF | | | EMERGENCY DISTRIBUTION SYSTEM AS ONE | | | SHEET SHOWS 800A ATS AND SPECS FOR ATS | | | INDICATE THIS AS 1000A'S? | | | PLEASE SEE NOTE BELOW AS PANEL | | | SCHEDULES ALSO INDICATE 1000A'S. | | | PLEASE KNOW, IF 1000A'S, GFP SENSING | | | WILL BE REQUIRED ON SECONDARY SIDE,GFP | | | WILL BE REQUIRED ON MAIN ALSO AS NOTED | | | PER 240.13,230.95. | | | PLEASE SEE 700.7D, 700.26, 701.9D | | | PLEASE SEE TEXT TAKEN DIRECTLY FROM ASCO | | | AS A 4-POLE ATS MAY BE REQUIRED FOR THE | | | CORRECT COORDINATION OF ELECTRICAL | | | SYSTEMS. | | | "WHERE GROUND FAULTPROTECTION IS | | | TRIGGERED BY THE CODE AND AN ALTERNATE | | | POWER SUPPLY IS INCLUDED,SWITCHING OF | | | THE NEUTRAL BECOMES NECESSARY. THE | | | CIRCUIT SHOWN ABOVE ILLUSTRATESSUCH A CIRCUMSTANCE. | | | THE SERVICE IS LARGER THAN | | | 1,000 AMPS. CONSEQUENTLY, GROUNDFAULT | | | PROTECTION IS REQUIRED AT THE MAIN | | | SERVICE DISCONNECT AT A MINIMUM. IF IT | | | IS INSTALLED THERE AND THE GENERATOR | | | NEUTRAL GROUNDING WAS THROUGH A SOLID | | | CONNECTION TO THE MAIN SERVICE NEUTRAL, | | | A GROUND FAULT WHEN THE GENERATOR IS | | | FEEDING THE LOAD WILL CAUSE THE MAIN | | | SERVICE DISCONNECT TO OPEN. THIS WILL | | | NOTDISCONNECT THE ARCING FAULT FROM | | | THE GENERATOR. COORDINATION IS THUS | | | LOST." | | | PLEASE VERIFY AS SYSTEM IN EXISTING BLDG | | | ONE MAY BE A SEPARATELY DERIVED | | | GENERATOR AND SEEING HOW BOTH BLDGS EM | | | POWER IS COMING FROM THE SAME GENERATOR, | | | A 4-POLE SWITCH MAY BE REQUIRED. PLEASE | | | ALSO KNOW, BOTH OF THESE MAIN | | | DISTRIBUTION SYSTEMS ARE COMING FROM TWO | | | SEPARATE FPL VAULTS AND TRANSFORMERS. | | | | | | 41)NOTE: PLEASE SEE MISSING FIRE PUMP | | | AND EQUIPMENT NOT INDICATED ON RISER | | | DIAGRAM. | | | PLEASE SEE 695.4B1 FOR OCP REQUIRED FOR | | | LOCKED ROTOR. PLEASE ALSO SEE NFPA-20 | | | FOR ELECTRICAL REQUIREMENTS FOR MEANS-OF | | | DISCONNECT, LOCATION ETC. PLEASE SEE | | | SPECS SUBMITTED APPEAR TO SHOW THIS , | | | HOWEVER NONE OF THESE ITEMS ARE SHOWN ON | | | RISER. UNABLE TO VERIFY CODE COMPLIANCE | | | FOR FIRE PUMP, FIRE PUMP CONTROLLER, | | | FEEDERS, SEC'S ETC. | | | ** PLEASE SEE SPECS WHICH CONTAIN THE | | | TITLE FROM STEVEN FELLER'S OFFICE | | | INDICATE THE PUMP AS 277/480V, 125HP. | | | 215.5 | | | | | | 42)NOTE: PLEASE CORRELATE ALL | | | TRANSFORMERS WITH SCHEDULE(S). PLEASE | | | SEE 112.5?, 150? KVA | | | PLEASE ALSO CONFIRM KVA AS MAX OCP FOR | | | TRANSFORMER MAY NOT EXCEED 125% AS 450.3 | | | TABLES. | | | 215.5 | | | | | | 43)NOTE: PLEASE COMPLETE BUS-DUCT RISER | | | AND METER CENTERS AS PLANS ONLY INDICATE | | | THESE THOUGH FLOOR (8).?? | | | PLEASE SEE MISSING METER CENTER / MAIN | | | DISCONNECT ON 3RD FLR, HOWEVER ONE IS | | | SHOWN ON 4.00 PLANS FOR ELECTRICAL RMS. | | | ALSO NOTED ABOVE FOR CORRELATION OF ALL | | | RMS WITH RISER. | | | 215.5 | | | | | | 44)NOTE: PLEASE PROVIDE THE COMPLETE | | | GROUNDING ELECTRODE SYSTEMS DETAIL PER | | | 250.50, 250.104, 250.64,,, | | | | | | 45)NOTE: PLEASE SEE EDPH2 IS SHOWN AS | | | 1000A'S ON PANEL SCHEDULES AND SHOWN AS | | | 800A ON RISER ?? PLEASE CORRELATE. | | | 215.5 | | | | | | 46)NOTE: PLEASE SEE "MSBE2" AS THIS IS | | | ALSO SHOWN AS 1000A'S ON PANEL | | | SCHEDULE(S), HOWEVER SHOWN AS 800A'S ON | | | RISER. PLEASE VERIFY AS 1000A'S OR MORE | | | 277/480V WILL ALSO REQUIRE GFP ON EM | | | MAIN. | | | 230.95,240.13 ETC | | | | | | 47)NOTE: PLEASE SEE PANEL "SL" IS SHOWN | | | AS HAVING "SITE LIGHTING" HOWEVER, SITE | | | LIGHTING COULD NOT BE LOCATED ON | | | ELECTRICAL PLANS? | | | IF SITE LIGHTING CONTAINS LT POLES, | | | PLEASE SUBMIT WIND LOAD CALCULATIONS | | | FOR FBC 140MPH. THESE WILL BE REVIEWED | | | BY A STRUCTURAL REVIEWER. ** PLEASE BE | | | SHOULD POLE CONTAIN FIXTURES FOR | | | CALCULATION PURPOSES. | | | | | | 48)NOTE: PLEASE VERIFY OCP FOR LARGER | | | A/C SYSTEMS SHOWN ON PANEL SCHEDULES, | | | PLEASE SEE 424.3B AS NOTED ABOVE FOR MIN | | | OCP OF 125%.ADJUST WHERE NEEDED. | | | RTU#1, #2, #3. PLEASE ALSO ADJUST AWG AS | | | NEEDED.310.16,240.4 | | | | | | 49)NOTE: PLEASE LABEL ALL TRANSFORMERS | | | ON RISER AS INDICATED ON PANEL | | | SCHEDULES. | | | 215.5 | | | | | | 50)NOTE: PLEASE VERIFY THE USE OF WHAT | | | APPEARS TO BE TANDEM BRKRS IN PANELS IN | | | THIS NEW CONSTRUCTION PROJECT?? | | | THIS IS ONLY A NOTE. | | | | | | 51)NOTE: PLEASE PROVIDE A DISCONNECT | | | DETAIL INCLUDING SIZE ETC FOR ROOF TOP | | | UNITS. THIS MAY BE A "TYPICAL" DETAIL | | | FOR EACH SIZE IF NOT ALL THE SAME. | | | 215.5,440.11 | | | | | | 52)NOTE: PLEASE SEE A BATTERY BACK UP LT | | | FIXTURE WILL BE REQUIRED IN THE MAIN | | | ELECTRICAL RM(S), PUMP RMS, FIRE COMMAND | | | RM, ELEVATOR EQUIPMENT RMS. | | | 700.16,700.12E, | | | | | | 53)NOTE: PLEASE SEE FAIR HOUSING ACT | | | REGULATIONS, 24 CFR 100.205 WITH RESPECT | | | TO THE LOCATIONS OF "ALL" ELECTRICAL | | | DEVICES, CONTROLS. | | | A NOTE IS LOCATED ON "GEN NOTES" WHICH | | | MENTIONS THE HEIGHTS FO RECEPTS AND | | | SWITCHES, HOWEVER THIS SHOULD REFLECT | | | FHAR ETC AS NOTED ABOVE. | | | | | | 54)NOTE: PLEASE SEE THE AMENITY DECK | | | DETAILS COULD NOT BE LOCATED IN SETS. | | | PLEASE SEE E2.06 WHICH ONLY SEEMS TO | | | INDICATE A PARTIAL AREA SHOWN. | | | PLEASE SEE NO ELECTRICAL SHOWN FOR | | | LIGHTING ETC? | | | PLEASE SEE LS 101 7.8 AND 7.9 WHICH | | | REQUIRES MEANS OF EGRESS LIGHTING TO THE | | | PUBLIC RIGHT OF WAY.; THIS WOULD INCLUDE | | | EMERGENCY LIGHTING AS REQUIRED. | | | PLANS NOW SHOW A SEPARATE PHASE LINE, AS | | | GARAGE WAS TO BE BUILT WITH PHASE ONE | | | BLDG AND DID NOT SHOW GARAGE WITH PHASE | | | LINE DOWN THE CENTER OF THE GARAGE. | | | | | | ** NOTE: PLEASE SEE MANY OF THE ABOVE | | | ITEMS WERE REDLINED ON ONE SET FOR AREAS | | | OF NOTES ABOVE. | | | | | | ** NOTE: PLEASE SEE POSSIBLE NOTES FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS AND DESIGN. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW ONCE ALL REVIEWS ARE COMPLETED. | | | IF THERE ARE NAY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | 2006-01-26 00:00:00 | IN PROGRESS | | 2006-01-25 00:00:00 | REVIEW STARTED, IN PROGRESS. | | | PLANS REVIEW STOPPED. NOTES TO FOLLOW, | | | AS REVIEW IS NOT COMPLETE. | | 2006-01-24 00:00:00 | | | | | | | I ROLL OF MEP'S AND I SUBMITTAL BOOK IN | | | ELECTRICAL FOR REVIEW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2006-03-10 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-03-10 |
Time |
14:09 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2006-03-10 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2006-03-10 00:00:00 | PASSED: | | | | | | 1. SEE PERMIT # 04110964 AND O4120334 | | | FOR UNDERGROUND UTILITIES AND SITE WORK. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-11-20 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-11-20 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2006-11-20 14:48:57 | ***DENIED*** | | | | | | PLEASE NOTE THAT IN SOME CASES WHERE THE ENGINEER | | | ACKNOWLEDGED WITH RESPONSE LETTER, IT WOULD HELP | | | EXPEDITE THE PLAN REVIEW PROCESS IF THE SHEET NUMBER IS | | | IDENTIFIED IN ADITION TO THE RESPONSE. | | | | | | COMMENT | | | | | | 1) OK | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4) OK | | | | | | 5) CD SHEETS STILL ILLUSTRATE (2) STAIRWELL #2. IS THIS | | | CORRECT? | | | | | | 6) PLEASE INDICATE SHEET NUMBER. | | | | | | 7) OK | | | | | | 8) OK | | | | | | 9) OK | | | | | | 10) OK | | | | | | 11) PLEASE INDICATE SHEET NUMBER | | | | | | 12) SHEET CD-10 STILL REFERENCES THE 1999 EDITION. | | | | | | 13) PLEASE INDICATE SHEET NUMBER | | | | | | 14) OK PLEASE INDICATE SHEET NUMBER | | | | | | 15) OK | | | | | | 16) OK | | | | | | 17) | | | | | | 18) NOT ADDRESSED IN RESPONSE LETTER. | | | | | | 19) NOT ADDRESSED IN RESPONSE LETTER. | | | | | | 20) OK | | | | | | 21) OK | | | | | | 22) OK | | | | | | 23) OK | | | | | | 24) OK | | | | | | 25) OK | | | | | | 26) OK | | | | | | 27) OK | | | | | | 28) OK | | | | | | 29) OK | | | | | | 30) OK | | | | | | 31) OK | | | | | | 32) A SMOKE CONTROL SYSTEM IS MENTIONED IN LETTER FROM | | | ATLAS. PLEASE CLARIFY IF THIS IS REFERENCING STAIRWELL | | | PRESSURIZATION? | | | | | | 33) OK | | | | | | 34) OK | | | | | | 35) OK | | | | | | 36) NOT PROVIDED OR UNABLE TO LOCATE. | | | | | | 37) OK | | | | | | 38) OK | | | | | | 39) OK | | | | | | 40)OK | | | | | | 41)OK | | | | | | 42) OK | | | | | | 43) NOTE ADDED THAT SD HAVE BEEN ADDED TO SHEETS. | | | PLEASE IDENTIFY SHEETS AS UNABLE TO LOCATE. | | | | | | 44) OK | | | | | | 45) OK | | | | | | 46) DEVICE STILL NOT SHOWING INSIDE UNIT. | | | | | | 47) OK PLEASE IDENTIFY SHEET NUMBER | | | | | | 48) OK PLEASE IDENTIFY SHEET NUMBER | | | | | | 49) OK | | | | | | 50) PLEASE FOLLOW CRITERIA IN ACCORDANCE WITH NFPA 13, | | | 2002 REF: ELECTRICAL VAULTS. | | | | | | 51) OK | | | | | | NEW COMMENTS: | | | | | | 1) NFPA 101 AND NFPA 1 2003 EDITIONS TO BE REFERENCED. | | | SHT CD-10 | | | | | | 2) NFPA 72, 2002 EDITION TO BE REFERENCED. SHT CD-10 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-01 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-01 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2006-03-01 00:00:00 | ******DENIED****** | | | | | | 1) FIRE HYDRANTS SHALL BE FULLY | | | OPERATIONAL PRIOR TO, DURING AND AFTER | | | CONSTRUCTION. | | | | | | 2) CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 3) PARKING GARAGE SHALL COMPLY WITH | | | APPLICABLE BUILDING CODES, AND NFPA 88A. | | | | | | | | | 4) KNOX BOXES ARE REQUIRED TO BE | | | INSTALLED WITH APPROPRIATE KEYS PRIOR TO | | | FINAL INSPECTION. | | | | | | 5) ARE STAIRWELLS NUMBERED CORRECTLY ON | | | CD SHTS? | | | | | | 6) NFPA 101, AND NFPA 1, 2003 EDITIONS | | | SHALL BE REFERENCED AFTER JAN. 1, 2005. | | | | | | 7) ALL REQUIREMENTS FOR HIGHRISE | | | BUILDINGS SHALL BE MET, AND BE IN | | | COMPLIANCE WITH NFPA 101, CHAPTER 11. | | | | | | 8) PLEASE INDICATE ON PLANS THAT ALL | | | WALKING SURFACES SHOWN ON SHT CD-03 ARE | | | SLIP RESISTANT. | | | | | | 9) PLEASE PROVIDE PRESCRIPTIVE STRENGTH | | | REQUIREMENT FOR HANDRAILS AND GUARDS. | | | | | | 10) MAXIMUM TRAVEL DISTANCE SHALL NOT | | | EXCEED 250' IN ACCORDANCE WITH NFPA 101, | | | SECTION 30.2.6.4. | | | | | | 11) NFPA 72, 2002 EDITION TO BE | | | REFERENCED. | | | | | | 12) NFPA 13, 2002 EDITION SHALL BE | | | REFERENCED. | | | | | | 13) TEMPORARY STANDPIPES ARE REQUIRED | | | WHEN THE BUILDING REACHES 3 STORIES OR | | | 30' IN HEIGHT. | | | | | | 14) AT LEAST (2) FIRE DEPARTMENT | | | CONNECTIONS ARE REQUIRED ON HIGHRISE | | | BUILDINGS. OK ON FIRE SPRINKLER SITE | | | PLAN. | | | | | | 15) LOCKING KNOX BOX CAPS REQUIRED ON | | | ALL FIRE DEPARTMENT CONNECTIONS. | | | | | | 16) DUCT SMOKE DETECTORS REQUIRED ON | | | SUPPLY SIDE OF AIR SYSTEM WITH | | | CAPABILITY GREATER THAN 2000 CFM. | | | | | | 17) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL. | | | | | | 18) FIRE ALARM SYSTEM TO BE UL CERTIFIED | | | FOR CENTRAL STATION SERVICE. | | | | | | 19) UL CERTIFICATION SHALL BE PROVIDED | | | PRIOR TO OR AT THE TIME OF FIRE ALARM | | | FINAL INSPECTION. | | | | | | 20) ACCESS ROADS SHALL BE A MINIMUM OF | | | 20' IN UNOBSTRUCTED WIDTH IN ACCORDANCE | | | WITH NFPA 1, CHAPTER 18. | | | | | | 21) AN ADDRESS IS REQUIRED ON BUILDING | | | AND SHALL BE A MINIMUM OF 3" IN HEIGHT | | | AND CONTRASTING WITH TO THE BACKGROUND. | | | | | | 22) FIRE EXTINGUISHER CABINET ONLY SHOWN | | | (1) LOCATION ON FL #1. PLEASE SHOW ALL | | | LOCATIONS IN BUILDING. | | | | | | 23) PLEASE INDICATE WHICH AELEVATORS ARE | | | SRTETCHER ACCESSIBLE. | | | | | | 24) TACTILE SIGNAGE IS REQUIRED AT | | | STAIRWELLS, INDICATING FLOOR NUMBER, | | | TOP, BOTTOM AND ROOF ACCESS. | | | | | | 25) NO STORAGE ALLOWED IN ELECTRICAL, | | | MECHANICAL OR FIRE COOMAND ROOMS. | | | | | | 26) NO COMBUSTIBLE STORAGE ABOVE | | | CEILINGS IF USED AS RETURN AIR PLENUM. | | | | | | 27) PLEASE INDICATE INTERIOR FINISH | | | CLASSIFICATION OF WALLS AND CEILINGS, | | | CLASS A,B OR C. | | | | | | 28) HANDRAILS ARE REQUIRED ON BOTH SIDES | | | OF STAIRS. | | | | | | 29) STAIRS TO COMPLY WITH APPLICABLE | | | BUILDING CODES, AND NFPA 101, CHAPTER 7. | | | | | | | | | 30) EXIT STAIRS ARE TO BE KEPT UP WITH | | | CONSTRUCTION. | | | | | | 31) ALL SHAFTS LARGE ENOUGH FOR PERSONS | | | TO FALL INTO MUST BE MARKED SHAFTWAY | | | WITH 6" HIGH LETTERS. | | | | | | 32) THE ANTICIPATED STACK EFFECT NOTE | | | WORDING SHALL BE ADDED TO THE MECHANICAL | | | PLANS. | | | | | | 33) NO CUTTING OR WELDING OPERATIONS TO | | | OCCUR WITHOUT APPROVAL OF THE BUREAU OF | | | FIRE PREVENTION AND COMPLIANCE WITH NFPA | | | 51B. | | | | | | 34) ELEVATORS TO COMPLY WITH ASME/ANSI | | | 17.1. | | | | | | 35) ELEVATOR LOBBIES SHALL HAVE WARNING | | | SIGNS. | | | | | | 36) PLEASE PROVIDE MANUFACTURER SPEC | | | SHEETS FOR CO DETECTORS IN PARKING | | | GARAGE. | | | | | | 37) SMOKE DETECTORS SHALL BE LOCATED AT | | | LEAST 3' FROM HVAC DIFFUSERS. | | | | | | 38) MORE EXIT SIGNS APPEAR TO BE NEEDED | | | IN LOBBY AND SURROUNDING AREA. | | | | | | 39) EXITS SIGNS TO BE MOUNTED AT | | | DISTANCES NOT TO EXCEED 100' AND MAKE | | | EXITING CLEAR AND OBVIOUS. | | | | | | 40) EMERGENCY LIGHTING FACILITIES ARE | | | REQUIRED IN ROOMS AND AREAS WHERE | | | ARTIFICIAL LIGHTING IS NOT ADEQUATE. | | | | | | 41) ARE EXIT LIGHTS AND EMERGENCY | | | LIGHTING FACILITIES MISSING IN THE | | | PARKING GARAGE? | | | | | | 42) WHERE ARE THE EXIT SIGNS LOCATED AT | | | STAIRS #1&2 LEADING PERSONS I REGARDS TO | | | EXITING? | | | | | | 43) SOME CORRIDOR SMOKE DETECTORS APPEAR | | | TO BE MISSING FROM ALL SHTS. PLEASE SHOW | | | ALL LOCATIONS. | | | | | | 44) FIRE ALARM SYSTEM TO MEET | | | SURVIVABILITY REQUIREMENTS OF NFPA 72. | | | | | | 45) FIRE ALARM SYSTEM TO BE CLASS A, | | | STYLE D OR FULLY ADDRESSABLE. | | | | | | 46) FIRE ALARM AUDIBLE DEVICE IS MISSING | | | IN UNIT B1C ON SHT E.7.01. | | | | | | 47) STANDPIPES CONNECTIONS SHALL BE 2 | | | 1/2" TO 1 1/2" REDUCER WITH CHAINS. | | | | | | 48) IN ADDITION TO ELECTRONIC | | | SUPERVISION, CHAIN AND LOCK IS REQUIRED | | | ON DOUBLE CHECK DETECTOR ASSEMBLY. | | | | | | 49) PLEASE PROVIDE FURTHER INFORMATION, | | | AND MANUFACTURER SPEC SHEETS FOR FIRE | | | PUMP. | | | | | | 50) FIRE SPRINKLERS ARE SHOWN IN | | | TRANSFORMER VAULT? IS THAT INTENDED OR | | | WILL THEY BE ELLIMINATED? | | | | | | 51) PLEASE SHOW LOCATION AND DETAILS FOR | | | DOUBLE CHECK DETECTOR ASSEMBLY. NOT | | | SHOWN ON FIRE PROTECTION SITE PLAN. | | | | | | 52) DO THE DOOR SWING AT THE ELECTRICAL | | | ROOM AND TRASH CHUTE OBSTRUCT THE | | | CORRIDOR BY GREATER THAN 1/2 THE WIDTH? | | | | | | 53) SMOKE EVACUATION IS MENTIONED. | | | PLEASE PROVIDE FURTHER INFORMATION. | | | | | | 54) SMOKE MANAGEMENT PANELS WHERE | | | PROVIDED SHALL PROVIDE A GRAPHIC | | | REPRESENTATION OF THE BUILDING. HOA | | | SWITCHES WITH NO OVERLAY OF THE BUILDING | | | WILL NOT BE ACCEPTABLE. | | | | | | 55) ARE THERE ANY ADA SPEAKER/STROBE | | | DEVICES PLANNED FOR ANY LIVING UNITS? | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLANS REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-04 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-13 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2006-10-04 00:00:00 | DENIED | | | REFERENCE: FBC-2001 FUEL GAS | | | | | | FROM THE PLUMBING REVIEW: | | | | | | | | | 1. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS APPLICATION: | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGHTS PER FBC-2004 | | | FUEL GAS. | | | ***RESPONSE NOTED, BUT CORRESPONDING | | | LENGTHS NOT SHOWN. FBC-2001 FUEL GAS. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | ***RESPONSE NOTED, BUT INFORMATION SHALL | | | BE LOCATED AT RISER WITH REQUIRED INFO. | | | SECTION 104.2.1. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | ***RESPONSE NOTED, INFORMATION REQUIRED | | | ON PLANS WITH RISER. | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | ***RESPONSE NOTED, BUT TOTAL BTU LOAD OF | | | SYSTEM NOT SHOWN. INFORMATION REQUIRED | | | ON PLANS WITH RISER. | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | ***NO RESPONSE NOT ADDRESSED. | | | | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. IF | | | 2 PSI INDICATE LOCATION OF REGULATORS | | | AND SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR REGULATORS INDICATING MODEL. IF | | | VENTED REGULATORS, INDICATE MATERIAL FOR | | | VENTS AND SHOW ROUTING OF PIPING. | | | ***NO RESPONSE, NOT ADDRESSED. | | | | | | I. SUBMIT MANUFACTURE SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ***NO RESPONSE, NOT ADDRESSED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-20 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-20 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2006-08-07 00:00:00 | WAITING FOR "COMM" BD | | | TO "COMM" BD#10/PLANS ON RACK-10 ROLLS/3 | | | BINDERS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-04-22 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2006-04-22 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-11-10 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2006-04-11 00:00:00 | COMM BD #36 | | | | | | | | 2006-01-11 00:00:00 | 12/29/05 PER MR JANOWSKI, PLANS ARE TO | | | BE PLACED ON "HOLD" AND NOT TO BE | | | REVIEWED UNTIL NEW REVISED PLANS ARE | | | BROUGHT IN. SEE ROBERT BROWN OR DEWEY | | | PALMER. | | 2005-12-05 00:00:00 | TO "COMM" BD#36/PLANS ON RACK/ 6 ROLLS | | 2005-11-10 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2006-10-10 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2006-10-04 00:00:00 | -----------------DENIED----------------- | | | NOTE:THESE COMMENTS ARE NUMBERED FOR | | | CONTINUITY WITH PREVIOUS PLAN REVIEW | | | COMMENTS AND RESPONSES. | | | | | | FBC 2001 | | | FBC,M 2001 | | | | | | 1. OK | | | | | | 2. PG.A8-10 RESIDENTIAL DOOR SCHEDULE: | | | MECHANICAL CLOSET DOORS INDICATES WOOD | | | DOORS WITH INTUMESCENT PAINT. ABSENT A | | | LISTING FROM AN APPROVED TESTING AGENCY | | | SHOWING THIS ASSEMBLY TO BE | | | NON-COMBUSTIBLE, IT MUST BE SUBMITTED | | | UNDER FBC 103.7.1 ALTERNATE MATERIALS | | | AND METHODS. | | | | | | 3. PG.M2-00 EF1 & EF2, PLEASE INDICATE | | | WHETHER THESE FANS ARE TO RUN CONTINUOUS | | | OR BE THERMOSTATICALLY CONTROLLED. WILL | | | THEY WORK IN ANY WAY IN CONJUNCTION WITH | | | GEF1 OR CO SENSORS? | | | | | | 4. OK | | | | | | 5. OK | | | | | | 6. PG.M2-01 NO LONGER SHOWS A CONDENSER | | | LOCATED INDOORS. HOWEVER, STORAGE ROOMS | | | X47 AND X48 DO NOT SHOW WHAT EQUIPMENT | | | IS TO BE USED. IF THEY ARE SPLIT SYSTEMS | | | THERE IS NO LOCATION OF CONDENSERS SHOWN | | | ON PLAN. | | | | | | 7. PG.M3-00 UNIT 'D1' SHOWS A 30X12 | | | RAFG. IS THIS A TRANSFER GRILL THROUGH A | | | WALL OR IS IT GOING INTO A PLENUM | | | CEILING?PER 601.4 A TRANSFER GRILL | | | WOULD REQUIRE A MINIMUM OF 450 SQ.IN. | | | SINCE IT IS RETUNING 900 CFM. IF THERE | | | IS A CEILING PLENUM, THERE CAN BE NO | | | EXHAUST DUCTS UNDER POSITIVE PRESSURE IN | | | THE PLENUM PER 601.3. | | | | | | 8. OK | | | | | | 9. PLEASE PROVIDE DETAIL/SPECS FOR TYPE | | | OF DRYER VENT HOOD (WALL CAP) TO BE | | | USED. TYPE OF WALL CAP MAY IMPACT | | | ALLOWABLE DRYER DUCT LENGTH PER DRYER | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS. | | | | | | 10. SUBMITTAL DATA FOR GOODMAN | | | RESIDENTIAL A/C EQUIPMENT ONLY SHOWS | | | COPPER LINE SIZES UP TO A LENGTH OF 35'. | | | PROVIDE DOCUMENTATION SIGNED AND SEALED | | | BY A GOODMAN ENGINEER (NOT A SALESMAN) | | | AFFIRMING SUITABILITY OF SPECIFIED | | | EQUIPMENT FOR COPPER LINE LENGTH AND | | | VERTICAL DISTANCE BETWEEN AIR HANDLERS | | | AND CONDENSING UNITS. PROPER COPPER LINE | | | SIZES FOR THIS APPLICATION ARE ALSO | | | REQUIRED. | | | | | | 11. OK | | | | | | 12. PG.M4-00 FBC 412.5 SMOKE CONTROL | | | REQUIRES REMOVAL OF THE PRODUCTS OF | | | COMBUSTION (SMOKE) VIA NATURAL OR | | | MECHANICAL VENTILLATION. PLEASE CLARIFY | | | HOW SMOKE IS TO BE REMOVED FROM EFFECTED | | | AREAS. THE SYSTEM DESCRIBED ON THIS PAGE | | | DOES NOT APPEAR TO BE RELATED IN ANY WAY | | | TO MEETING THE REQUIREMENTS OF FBC | | | 412.5. | | | | | | 13. OK | | | | | | 14. OK | | | | | | 15. PG.M5-01 DETAIL #11 STILL SHOWS DUCT | | | SMOKE DETECTOR IN R/A PLENUM. DUCT SMOKE | | | DETECTORS ARE TO BE INSTALLED IN SUPPLY DUCTS | | | PER FBC,M 606.2.1. | | | | | | PLEASE NOTE: THIS REFERS TO DETAIL #11, NOT DETAIL #4. | | | | | | 16. OK | | | | | | 17. OK | | | | | | 18. OK | | | | | | 19. PG.M2-00 AHU 1 SHOWS 16X14 SUPPLY AND | | | 10" ROUND O/A DUCTS PENETRATING RATED WALLS. IT | | | IS NOT CLEAR ON PLANS IF AHU 1 O/A INTAKE | | | COMPLIES WITH FBC,M 401.5.1 INTAKE OPENINGS. | | | ITS PROXIMITY TO A PARKING SPACE INDICATES IT IS | | | IN THE PARKING GARAGE, WHICH IS A PROHIBITED LOCATION. | | | | | | 20. PG.M2-00 AHU 1 DOES NOT SHOW ANY | | | RETURN AIR FROM LOBBY OR MAIL ROOM AREAS. | | | | | | 21. PG.M2-00 6" ROUND SUPPLY TO MAIL ROOM | | | SHOWS A FIRE DAMPER IN-LINE.HOW WILL FIRE | | | DAMPER ACCESS BE PROVIDED IN FLEXIBLE DUCT? | | | | | | 22. PG.M2-00 AHU 2 DOES NOT SHOW ANY | | | RETURN AIR FROM SUNDRIES SHOP. | | | | | | 23. PG.M3-00 - M3-02 UNITS C,D1,D2,D3, | | | E,F,G,P1,P2,P3 SHOW TRANSFER GRILLS LOW ON | | | ONE SIDE OF WALL AND HIGH ON OTHER SIDE. IS | | | THE INTENTION TO USE THE STUD WALL CAVITY TO | | | CONVEY RETURN AIR FROM BEDROOMS? IF SO, | | | PLEASE PROVIDE DETAIL SHOWING COMPLIANCE | | | WITH BOTH FBC,M 602.3(5) AND FBC CH.13 | | | SECTION 610.1.ABC.3.6. | | | | | | 24. PG.M4-00 NO INFORMATION IS PROVIDED | | | AS TO TYPE OF DUCT TO BE USED IN SHAFTS OR | | | THE REQUIRED THICKNESS/R-VALUE OF DUCT | | | INSULATION. ENSURE DIMENSIONS OF SHAFTS ARE | | | LARGE ENOUGH TO ACCOMODATE DUCT INSULATION | | | DIMENSIONS WITH SUPPORTS AND STANDING | | | SEAMS AT DUCT JOINTS. | | | | | | 25. PG.M4-00 RTU SYSTEMS 1,2,3 SHOW | | | 24X24 DIFFUSERS IN CORRIDORS. WHAT SIZE | | | NECKS AND DUCT CONNECTIONS ARE NEEDED | | | TO ACHIEVE DESIRED CFM? | | | | | | 26. PG.M4-00 PLEASE GIVE DETAILS AS TO HOW | | | DESIGN CFM IS TO BE ACHIEVED DURING | | | CORRIDOR PRESSURIZATION MODE. EXAMPLE: | | | RTU 1 IS RATED FOR 8,600 CFM. IF ALL SMOKE | | | DAMPERS EXCEPT TWO (FLOOR ABOVE AND FLOOR | | | BELOW) ARE CLOSED, WILL FAN SPEED BE ADJUSTED | | | TO PROVIDE CFM CALLED FOR ON PLAN DURING THIS | | | MODE? WILL CORRIDOR DUCT BE CONSTRUCTED SO | | | AS TO WITHSTAND THE ADDITIONAL | | | VOLUME/PRESSURE? | | | | | | 27. PG.M4-00 RTU SYSTEMS 2,3 SHOW ONE | | | 24X24 DIFFUSER ON EACH FLOOR BUT THERE IS A | | | NOTE AT THE LOCATION WHICH SAYS "(QTY 2)". | | | PLEASE CLARIFY. | | | | | | 28. PG.M4-01 RD-1 AND RD-2 REMOVE FIRE | | | DAMPERS FROM THESE LOCATIONS AS A CLOSED | | | FIRE DAMPER BLADE WILL ADVERSELY EFFECT THE | | | PERFORMANCE OF THE STAIRWELL PRESSURIZATION | | | SYSTEM. | | | | | | 29. PG.M4-01 SPF-1 AND SPF-2 REQUIRE DUCT | | | SMOKE DETECTORS PER FBC,M 606.2.1 AS | | | THEY EXCEED 2,000 CFM. | | | | | | 30. PG.M5-00 PLEASE PROVIDE ALL RELEVANT SUB- | | | MITTAL DATA FOR EXHAUST FANS AND RTUS. | | | | | | 31. PG.M5-01 DETAIL 4 AND 9, PLEASE PROVIDE | | | DETAILS FOR ATTACHING CURBS, STANDS, DUCTS AND | | | EQUIPMENT ON ROOF PER FBC,M 301.13.NOTE: | | | THE CITY OF WEST PALM BEACH IS IN THE 140 MPH | | | ZONE PER FBC 1606. | | | | | | 32. PG.M5-01 ALL FIR OR FIRE/SMOKE DAMPERS ARE | | | TO BE UL 555 LISTED AND INSTALLED PER MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS PER FBC,M 607.1.2. | | | | | | REVIEW BY: RONALD J REGUEIRO | | | 561-805-6734 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-02-13 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-02-13 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2006-02-13 00:00:00 | DENIED:2001 FLORIDA BUILDING CODE | | | | | | 1.PLAN SHEET A6-70 DETAIL 5 & 8 | | | MECHANICAL EQUIPMENT RACK DETAIL, | | | DETAILS DO NOT INDICATE THE ATTACHMENT | | | TO THE STRUCTURE.PLEASE SHOW | | | COMPLIANCE WITH 2001 FMC 301.13 & | | | CHAPTER 16 OF THE 2001 FBC. | | | | | | 2.PLAN SHEET A8-10 RESIDENTIAL DOOR | | | SCHEDULE, THE MECHANICAL CLOSET | | | REFERENCES NOTE #9 WHICH STATES THE | | | INTERIOR OF THE CLOSET DOOR & FRAME WILL | | | BE PAINTED WITH INTUMESCENT PAINT.IS | | | THE INTENT OF THE PAINT TO CLASSIFY THE | | | DOOR AS "NON-COMBUSTIBLE"?WILL THE | | | DOOR BE NON-COMBUSTIBLE WITHOUT THE | | | PAINT? | | | | | | 3.PLAN SHEET M2-00 THE OUTSIDE AIR TO | | | THE MAIN ELECTRICAL ROOM IS SUPPLIED | | | FROM THE GARAGE & LOADING AREA?PLEASE | | | CLARIFY.PLAN SHEET A9-01 INDICATES A 1 | | | HR SEPARATION.PER 2001 FMC 401.5.1, | | | INTAKE OPENINGS SHALL BE LOCATED A | | | MINIMUM OF 10 FT FROM HAZARDOUS OR | | | NOXIOUS CONTAMINANT SUCH AS PARKING LOTS | | | AND LOADING DOCKS. | | | | | | 4.PLAN SHEET M2-00 INDICATES A 32" X | | | 12" LOUVER BETWEEN THE PUMP ROOM & THE | | | DOMESTIC PUMP ROOM. PLAN SHEET A9-01 | | | INDICATES A 1 HR SEPARATION BETWEEN | | | THESE ROOMS.PLEASE CLARIFY.THIS ALSO | | | EFFECTS THE EXHAUST FROM THE PUMP ROOM & | | | THE MAIN ELECTRICAL ROOM. | | | | | | 5.PLAN SHEET M2-00 EXHAUST DUCT FROM | | | MENS ROOM PENETRATES 1 HR SEPARATION TO | | | THE FIRE COMMAND ROOM.SHOW COMPLIANCE | | | WITH 2001 FMC 607.1.3 (3) ITEMS 1 | | | THROUGH 4. | | | | | | 6.PLAN SHEET M2-01 AHU & CONDENSOR | | | LOCATED IN THE GARAGE.PLEASE PROVIDE | | | MANUFACTURERS SUBMITTAL/INSTALLATION | | | DATA, FOR INSTALLATION OF THE CONDENSER | | | LOCATED INDOORS. | | | | | | 7.PLAN SHEET M3-00 THROUGH M3-02, PER | | | 2001 FMC 601.4 RETURN AIR REQUIRED FROM | | | ROOMS SEPARATED FROM THE CENTRAL RETURN | | | BY DOORS.TRANSFER GRILLES OR JUMPERS | | | SHALL BE SIZED IN ACCORDANCE WITH 2001 | | | FMC 601.4 EXCEPTION 1 THROUGH 3. | | | | | | 8.PLEASE INDICATE MATERIAL OF DRYER | | | DUCT.SHOW COMPLIANCE WITH 2001 FMC | | | 504.2. & 504.4. | | | | | | 9.PLAN SHEET M3-00 THROUGH M3-02, | | | DRYER EXHAUST APPEARS TO EXCEED THE | | | MANUFACTURERS REQUIREMENTS WITH THE | | | OFFSETS.PLEASE CLARIFY. | | | | | | 10.PLEASE PROVIDE MANUFACTURER | | | SUBMITTAL DATA FOR THE RESIDENTIAL A/C | | | EQUIPMENT.PLEASE VERIFY MAXIMUM LENGTH | | | OF REFRIGERANT LINES.INDICATE SIZING. | | | | | | 11.REFRIGERANT LINES SHALL BE IN A | | | VENTED SHAFT IN ACCORDANCE WITH ASHRAE | | | 15-92. | | | | | | 12. PLAN SHEET M4-00 REFERENCES 2001 FBC | | | 412.5 FOR THE SMOKE CONTROL.PLEASE | | | INDICATE WHICH METHOD WILL BE USED. | | | 412.5 HAS 3 PRESCRIPTIVE METHODS AND ONE | | | ENGINEERED METHOD THAT IS REQUIRED TO | | | DEMONSTRATE THE MITIGATION OR REMOVAL OF | | | SMOKE.PLEASE CLARIFY. | | | | | | 13. PLAN SHEET M5-00 APARTMENT DRYER | | | DATA UNIT A3 IS INDICATED AS REQUIRING A | | | BOOSTER FAN OR ARCHITECTURAL REDESIGN. | | | PLEASE NOTE, BOOSTER FANS MUST BE | | | SUBMITTED UNDER 103.7.1, ALTERNATE | | | MATERIALS & METHODS.PLEASE PROVIDE ALL | | | PERTINANT INFORMATION.PROVIDE LETTER | | | FROM AN ENGINEER EMPLOYED BY THE | | | MANUFACTURER STATING THE INSTALLATION OF | | | A DRYER BOOSTER FAN WILL NOT VOID THE | | | WARRANTY OF THE DRYER. | | | | | | 14. ALL LIFE SAFETY ITEMS AS WELL AS THE | | | GARAGE VENTILATION FANS AND CO SENSORS | | | SHALL HAVE THE CAPABILITY TO OPERATE | | | UNDER EMERGENCY POWER. | | | | | | 15. PLAN SHEET M5-01 DETAIL 11 INDICATES | | | DUCT SMOKE DETECTOR IN THE RETURN AIR | | | PLENUM.PER 2001 FMC 606.2.1, SMOKE | | | DETECTORS SHALL BE INSTALLED IN THE | | | SUPPLY AIR DUCT. | | | | | | 16. PLEASE CLARIFY CONDENSATE, PLAN | | | SHEET P4-05 & P4-06 DOES NOT INDICATE | | | WHERE THE CONDENSATE TERMINATES (STORM | | | DRAIN OR SANITARY).PLEASE CLARIFY. PER | | | CITY CODE SEC.90-125 PROHIBITIONS & | | | LIMITATIONS OF DISCHARGE (5), CONDENSATE | | | SHALL NOT DISCHARGE INTO SANITARY. | | | CONDENSATE SHALL TERMINATEINTO THE | | | STORM DRAIN SYSTEM.PLEASE NOTE, | | | CONDENSATE PIPING IN THE AHU CLOSET | | | SHALL BE N0N-COMBUSTIBLE (NO PVC) PER | | | 2001 FMC 602.2.1. | | | | | | 17. TRASH CHUTE SHALL BE SPRINKLERED IN | | | ACCORDANCE WITH 2001 FBC 705.2.4.6. | | | | | | 18. PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS IN ACCORDANCE WITH TABLE | | | 403.3 FOR ALL AREAS (I.E. RESIDENCE & | | | COMMON AREAS). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-10-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-03 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-13 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2006-10-03 00:00:00 | *****BECAUSE OF THE SYSTEM LIMITIONS, | | | THE SECOND REVIEW NOTES WILL BE SPLIT UP | | | INTO TWO REVIEW STOPS. THE FOLLOWING IS | | | THE COMMENTS FROM THE SECOND REVIEW. | | | | | | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FHA- 98DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | CITY MUNICIPAL CODE WPB | | | | | | *************NEW COMMENTS************** | | | | | | 1B. SHTS P2-00 & P2-01 NO CD/5 SHOWN. | | | PLEASE CORRELATE RISER WITH FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 2B. SHT P2-02B NO SECONDARY DRAINS | | | SHOWN. - NO DRAINAGE SHOWN IN THE TENNIS | | | COURT AREA, NOR IN THE AMENITY DECK AREA | | | AS REQUIRED IN SECTIONS 1101.2, 1107.1, | | | 1107.2 & 1107.3. | | | | | | 3B. SHT P2-02B 3 DRAINS SHOWN ARE NOT | | | REFLECTED ON THE RISER DIAGRAM. PLEASE | | | CORRELATE DRAINS WITH RISER DIAGRAM. | | | SECTION 104.2.1. | | | | | | 4B. SHT P2-02B TOTAL AREA OF TERRACE | | | LEVEL DOES NOT APPEAR TO BE SHOWN ON THE | | | FLOOR PLAN. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | 5B. TWO CD/5 RISERS SHOWN. PLEASE | | | CLARIFY. SECTION 104.2.1. | | | | | | 6B. SHT P4-00 RISER SV1 DOES NOT REFLECT | | | THE FLOOR PLAN 1ST FLOOR UNDERGROUND. | | | SV1 ON THE FLOOR PLAN FOR ONE RISER | | | SHOWS AN OFFSET, BUT ANOTHER SV1 ON THE | | | FLOOR PLAN DOES NOT SHOW AN OFFSET. THE | | | RISER DOES NOT REFLECT THE FLOOR PLAN | | | AFTER THE OFFSET. RISERS SHALL BE | | | SPECIFIC TO THE FLOOR PLAN. DIFFERENT | | | FLOOR PLANS REQUIRE DIFFERENT RISERS. | | | SECTION 104.2.1. | | | | | | 7B. SHT P4-00 RISER SV2 DOES NOT REFLECT | | | THE FLOOR PLAN FOR THE 1ST FLOOR | | | UNDERGROUND. CORRELATE RISER AND FLOOR | | | PLAN. SECTION 104.2.1. | | | | | | 8B. SHT P4-00 RISER SV3 DOES NOT REFLECT | | | THE FLOOR PLAN. ALSO OFFSET ON ONE FLOOR | | | PLAN RISER BUT NOT THE OTHER. OFFSET | | | PIPING AND PIPING FOR 12 THRU 16 FLOORS | | | DO NOT REFLECT THE FLOOR PLAN. CORRELATE | | | RISER AND FLOOR PLAN. SECTION 104.2.1. | | | | | | 9B. SHT P4-00 RISER SV4 DOES NOT REFLECT | | | THE FLOOR PLAN. CORRELATE THE RISER AND | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | 10B. SHT P4-00 SV5 DOES NOT REFLECT THE | | | FLOOR PLAN. SOME ALSO SHOW TUBS WHILE | | | THE OTHERS SHOW SHOWERS. OFFSET PIPING | | | ONLY SHOWN ON THE FLOOR PLAN FOR ONE. | | | PIPING AFTER THE OFFSET DOES NOT REFLECT | | | THE FLOOR PLAN. CORRELATE RISER AND | | | FLOOR PLANS. SECTION 104.2.1. | | | | | | 11B. SHT P4-00 RISER SV6 2ND THRU 5TH | | | FLOORS NOT PIPED THE SAME ON ALL FLOOR | | | PLANS. 2 FLOOR PLANS RELFECT THE FLOOR | | | PLAN, BUT THE OTHER DOES NOT. TYPICAL | | | RISERS DO NOT WORK AS THE FLOOR PLANS | | | ARE DIFFERENT. RISER SHALL REFLECT THE | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | 12B. SHT P4-00A SV7 DOES NOT REFLECT THE | | | OFFSET ON THE FLOOR PLAN, AND IS NOT | | | SHOWN ON THE FIRST FIVE FLOORS. | | | CORRELATE THE RISER AND THE FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 13B. SHT P4-00A TWO SV9 RISERS SHOWN. | | | NEITHER INDICATE A FIRST FLOOR BATHROOM. | | | ONE FLOOR PLAN SV9 SHOWS A BATHROOM. | | | DOES NOT REFLECT THE FLOOR PLAN AT | | | OFFSET. PLEASE CLARIFY. SECTION 104.2.1. | | | | | | 14B. SHT P4-00A SV10 IS NOT INDICATED ON | | | THE FLOOR PLAN OF SHT P2-00 AND DOES NOT | | | REFLECT THE FLOOR PLAN AT THE OFFSET. | | | PLEASE CORRELATE RISER AND FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 15B. SHT P4-00A SV12 OFFSET ON FLOOR | | | PLAN NOT SHOWN ON THE RISER DIAGRAM. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 16B. SHT P4-00B SV13 DOES NOT REFLECT | | | THE FLOOR PLAN AT THE FIRST FLOOR | | | UNDERGROUND, AND VENT NOT SHOWN ON THE | | | 11TH THRU 16TH FLOOR. FLOOR PLAN SHOWS | | | ONE SV13 CONNECTING TO SHOWER DRAIN. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 17B. SHT P4-00B SV14 DOES NOT REFLECT | | | THE FLOOR PLAN 1ST FLOOR UNDERGROUND. | | | ONE FLOOR PLAN SHOWS NO FIXTURES THRU | | | THE FIRST FIVE FLOORS. DOES NOT REFLECT | | | AT THE OFFSET, SHOWN AS SHOWERS ON FLOOR | | | PLAN 11TH THRU 16TH FLOORS FOR ONE RISER | | | AND NOT SHOWN AS VTR ON ONE RISER. | | | PLEASE CORRELATE RISER AND FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 18B. SHT P4-00B SV15 DOES NOT REFLECT | | | THE FLOOR PLAN 1ST FLOOR UNDERGROUND, | | | AND ONE RISER SHOWN ON THE FLOOR PLAN | | | INDICATES FIXTURES ON THE FIRST FLOOR. | | | PLEASE CORRELATE RISER AND FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 19B. SHT P4-00B SV16 DOES NOT REFLECT | | | THE FLOOR PLAN 1ST FLOOR UNDERGROUND. | | | FLOOR PLANS ALSO SHOWS NO FIXTURES ON | | | FIRST FLOOR. CORRELATE RISER WITH FLOOR | | | PLANS. SECTION 104.2.1. | | | | | | 20B. SHT P4-00B SV17 NOT FOUND ON THE | | | FIRST FLOOR PIPING LAYOUT SHT P2-00. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 21B. SHT P4-01 RISER P1 OFFSET VENTS | | | REQUIRED. SECTIONS 915.2 & 915.3. | | | | | | 22B. SHT P4-01 RISER P2 RISER SHOWS NO | | | BRANCH LINE FOR 5TH FLOOR. DOES NOT | | | REFLECT THE FLOOR PLAN. CORRELATE RISER | | | AND FLOOR PLAN. SECTION 104.2.1. | | | | | | 23B. SHT P4-01 RISER P3 REFLECTS ONE | | | FLOOR PLAN BUT NOT THE OTHER. FLOOR | | | PLANS ARE NOT TYPICAL. SEPARATE RISERS | | | REQUIRED. SECTION 104.2.1. | | | | | | 24B. SHT P4-01 RISER P4 CHANGES TO P15 | | | ONE FLOOR PLAN FOR ONE P4. PLEASE | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 25B. SHT P4-01 RISER P5 DOES NOT REFLECT | | | THE FLOOR PLAN 1ST FLOOR. CORRELATE THE | | | RISER AND THE FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 26B. SHT P4-01 RISERS P7, (10), SOME | | | DIFFER FROM OTHERS. SOME DO NOT SHOW | | | FIXTURES ON THE FIRST FLOOR. RISER CAN | | | NOT BE TYPICAL IF FLOOR PLAN IS NOT THE | | | SAME. PLEASE CORRELATE RISERS TO FLOOR | | | PLAN. SECTION 104.2.1. | | | | | | 27B. SHT P4-01 RISER P8 ONE RISER STARTS | | | ON THE 1ST FLOOR AND IS NOT SHOWN ON THE | | | 6TH FLOOR & OFFSET DOES NOT REFLECT THE | | | FLOOR PLAN. CORRELATE RISER AND FLOOR | | | PLANS. SECTION 104.2.1. | | | | | | 28B. SHT P4-01 RISER P9 RISER DOES NOT | | | REFLECT THE FLOOR PLAN ON ONE 1ST THRU | | | 5TH FLOORS NO FIXTURE BRANCH. NOT SHOWN | | | ABOVE THE 5TH FLOOR AT ALL ON ONE FLOOR | | | PLAN. CORRELATE RISER AND FLOOR PLANS. | | | SECTION 104.2.1. | | | | | | 29B. SHT P4-01A RISER P15 CHANGES TO P4 | | | ON SHT P2-01. PLEASE CORRELATE RISER AND | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | 30B. SHT P4-01A RISER P17 DOES NOT | | | REFLECT THE FLOOR PLAN AT THE FIRST | | | FLOOR. CORRELATE RISER AND FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 31B. SHT P4-01B RISER P18 NOT INDICATED | | | ON FLOORS 1 THRU 5. CORRELATE RISER AND | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | 32B. SHT P4-01B RISER P20 OFFSET VENTS | | | REQUIRED. SECTIONS 915.2 & 915.3. | | | | | | 33B. SHT P4-02 RISER 11 DOES NOT REFLECT | | | THE FLOOR PLAN 6TH FLOOR. OFFSET NOT | | | SHOWN. CORRELATE RISER AND FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 34B. SHT 4-02 RISER 1/2 DOES NOT REFLECT | | | THE FLOOR PLAN 1ST & 2ND FLOORS. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 35B. SHT P4-02 RISER CONNECTIONS TO THE | | | MAIN FOR RISERS 9/10 & 11 DO NOT REFLECT | | | THE FLOOR PLAN. CORRELATE THE RISER AND | | | THE FLOOR PLAN. SECTION 104.2.1. | | | | | | 36B. SHT P4-02 RISER CONNECTIONS TO MAIN | | | FOR RISERS 17, 18/19, & 20/21 DO NOT | | | REFLECT THE FLOOR PLAN. PLEASE CORRELATE | | | RISERS AND FLOOR PLAN. SECTION 104.2.1. | | | | | | 37B. SHT P4-03 RISER 18/19 DOES NOT | | | REFLECT THE FLOOR PLAN. PLEASE CORRELATE | | | THE FLOOR PLAN AND RISERS. SECTION | | | 104.2.1. | | | | | | 38B. SHT P4-03 RISER 20 DOES NOT REFLECT | | | THE FLOOR PLAN 7TH THRU 10TH FLOORS. | | | OFFSET NOT SHOWN. CORRELATE RISER AND | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | 39B. SHT P4-03 RISER 20/21 DOES NOT | | | REFLECT THE FLOOR PLAN 1ST THRU 6TH | | | FLOORS. CORRELATE RISER AND FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 40B. SHT P4-04 RD4 RISER DOES NOT | | | REFLECT THE FLOOR PLAN. OFFSETS NOT | | | SHOWN. CORRELATE THE RISER WITH THE | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | 41B. SHT P4-04 RD6 RISER DOES NOT | | | REFLECT THE FLOOR PLAN. OFFSET NOT | | | SHOWN. CORRELATE THE RISER AND THE FLOOR | | | PLAN. SECTION 104.2.1. | | | | | | 42B. SHT P4-04 RD16 RISER DOES NOT | | | REFLECT THE FLOOR PLAN. OFFSET NOT | | | SHOWN. CORRELATE THE RISER AND THE FLOOR | | | PLAN. SECTION 104.2.1. | | | | | | 43B. SHT P4-05 CD RISER #5 DOES NOT | | | REFLECT THE FLOOR PLAN 11TH FLOOR AND | | | ABOVE. CORRELATE RISER AND FLOOR PLANS. | | | SECTION 104.2.1. | | | | | | 44B. SHT P4-05 CD RISER #2 DOES NOT | | | REFLECT THE FLOOR PLAN AT THE 11TH | | | FLOOR. OFFSET NOT SHOWN. CORRELATE RISER | | | WITH FLOOR PLAN. SECTION 104.2.1. | | | | | | 45B. SHEETS FOR ALL FLOOR PLANS. KEYED | | | NOTES ARE NOT SHOWN ON ALL FLOOR PLANS. | | | PLEASE CLARIFY. SECTION 104.2.1. | | | | | | 46B. SHT PO-01 CODE REFERENCE TO | | | IBC-2000 AND INTERNATIONAL ENERGY | | | CONSERVATION CODE 2000 DO NOT APPLY. | | | ADOPTED CODE IS THE FBC-2001 PLUMBING | | | CODE ONLY. DELETE OTHER REFERENCES. | | | | | | 47B. SHT PO-01 HORIZONTAL STORM DRAINAGE | | | PIPING REFERENCES FBC-2004. ADOPTED CODE | | | IS FBC-2001. | | | | | | 48B. SHT P2-00 INDICATES SV19 RISER ON | | | THE FLOOR PLAN. NO SV19 RISER SUBMITTED. | | | PLEASE CLARIFY. SECTION 104.2.1. | | | | | | 49B. SHT P2-00KEYED NOTE #1 HAS BEEN | | | CHANGED TO NOTE #3 ON THE FLOOR PLAN AND | | | NOTE #3 DOES NOT APPLY. PLEASE CORRELATE | | | KEYED NOTES WITH INFORMATION INDICATED | | | ON THE FLOOR PLAN. SECTION 104.2.1. | | | | | | 50B. SHT P2-00 THE PIPE SIZE FOR THE | | | STORM SYSTEM IS INCORRECT IN SOME | | | PLACES. RECHECK ALL PIPE SIZES PER TABLE | | | 1106.3. | | | | | | 51B. SHT P2-00 NOT ALL KEYED NOTES SHOWN | | | ON THE FLOOR PLAN REFLECT THE FLOOR | | | PLAN. (EXAMPLE, KEYED NOTE #2 ON THE | | | FLOOR PLAN SHOWS A CONDENSATE LINE | | | OFFSET, BUT THE KEYED NOTED IN THE INDEX | | | STATES "4" STORM DOWN FROM TERACE | | | ABOVE"). PLEASE CORRELATE KEYED NOTES | | | WITH INFORMATION INDICATED ON THE FLOOR | | | PLAN. | | | | | | 52B. SHT P2-01 INDICATES 2ND THRU 5TH | | | FLOORS. THERE ARE OFFSETS SHOWN ON THE | | | FLOOR PLAN. ARE THESE OFFSETS TYPICAL | | | FOR ALL FLOORS? IF NOT THEN FLOOR PLANS | | | THAT ARE NOT TYPICAL SHALL BE SUBMITTED | | | INDIVIDUALLY AND NOT SHOWN AS TYPICAL. | | | (SEE KEYED NOTE #8, "ROUTE PIPING | | | SUSPENDED FROM CEILING ON THIS LEVEL". | | | LEVEL NOT INDICATED)PLEASE CLARIFY. | | | SECTION 104.2.1. | | | | | | 53B. SHT P2-01 SV9 SHOWN IN THE BLOCK | | | WALL FOR STAIRWELL #1. PLEASE INDICATE | | | HOW THE FIRE RATING WILL BE MAINTAINED | | | FOR THE STAIRWELL. ALSO SHOW COMPLIANCE | | | WITH SECTIONS 1907.3, 1907.4, | | | 1907.5(1)(3), AND 1907.3.6(3). SUBMIT A | | | DETAIL. | | | SECTION 104.2.3. | | | | | | 54B. SHT P2-01 NOT ALL KEYED NOTES SHOWN | | | ON THE FLOOR PLAN REFLECT THE FLOOR | | | PLAN. (EXAMPLE, KEYED NOTE #2 STATES | | | "OFFSET 2" SANITARY DRAIN" AND IS | | | INDICATED ON A CONDENSATE LINE). | | | CORRELATE KEYED NOTES AND FLOOR PLAN. | | | SECTION 104.2.1. | | | | | | 55B. SHT P2-01 SHEET APPEARS TO BE | | | INCOMPLETE. SHOW A MATCH LINE AND | | | INDICATE WHERE THE REST OF THE FLOOR | | | PLAN CAN BE LOCATED, OR SUBMIT A SHEET | | | THAT IS 100% COMPLETE. SECTION 104.2.1. | | | | | | 56B. SHT P2-01 RD11 SHOWS AN OFFSET ON | | | THE FLOOR PLAN THAT IS NOT REFLECTED ON | | | THE RISER DIAGRAM. PLEASE CORRELATE THE | | | RISER WITH THE FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 57B. SHT P2-01 RISER 8, 9, 10 DOES NOT | | | INDICATE WHERE THE RISER ROUTES DOWN TO | | | THE FLOOR BELOW. PLEASE CLARIFY SECTION | | | 104.2.1. | | | | | | 58B. SHT P2-01B RECHECK PIPE SIZING AS | | | SOME SIZING IS INCORRECT. ALSO SOME AREA | | | DRAINS ARE SHOWN AS PLANTER DRAINS AND | | | SOME PLANTER DRAINS ARE SHOWN AS AREA | | | DRAINS. CORRELATE RISER AND FLOOR PLAN. | | | SECTION 104.2.1 AND TABLE 1106.3. | | | | | | 59B. SHT P2-01B SHOW THE SF OF EACH | | | DRAIN AND INDICATE SQUARE FOOTAGE AS IT | | | ACCUMULATES IN THE SYSTEM. TABLE 1106.3. | | | | | | 60B. SHT P2-02 CD5 SHOWN ON FLOOR PLAN | | | WAS NOT SHOWN ON FLOORS 1 THRU 5. | | | INDICATE WHERE CD5 TERMINATES. SECTION | | | 104.2.1. | | | | | | 61B. SHT P2-02B THREE PLANTER DRAINS | | | SHOWN ON THE FLOOR PLAN ARE NOT SHOWN | | | ON THE RISER DIAGRAM. CORRELATE THE | | | RISER AND THE FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 62B. SHT P2-02B NO DRAINAGE IS SHOWN FOR | | | THE AMENITY DECK AREA NOR FOR THE TENNIS | | | COURT AREA AS REQUIRED BY SECTION | | | 1101.2. PLEASE CLARIFY. | | | | | | 63B. SHT P2-02B SHOW THE LOCATION FOR | | | ALL REQUIRED SECONDARY ROOF DRAINS, AND | | | INDICATE THE SIZE. SECTIONS 1107.1, | | | 1107.2, & 1107.3. | | | | | | 64B. SHT P2-03 IS FOR FLOORS 7 THRU 10. | | | THERE ARE OFFSETS SHOWN ON THE FLOOR | | | PLAN. ARE THESE OFFSETS FOR EACH FLOOR? | | | IF NOT THE FLOORS CAN NOT BE TYPICAL, | | | AND INDIVIDUAL SHEETS ARE REQUIRED FOR | | | EACH FLOOR THAT IS NOT TYPICAL. SECTION | | | 104.2.1. | | | | | | 65B. SHT P2-03 KEYED NOTES DO NOT | | | REFLECT WHERE THEY ARE APPLIED ON THE | | | FLOOR PLAN. CORRELATE KEYED NOTES AND | | | THE FLOOR PLAN. SECTION 104.2.1. | | | | | | 66B. P2-05 IS FOR SHEETS 12, 14 THRU 16. | | | THERE ARE OFFSETS SHOWN ON THE FLOOR | | | PLAN, AND VENTS CONNECTING TO EACH OTHER | | | AND VENTING THRU THE ROOF. ARE THESE | | | OFFSETS AND VENTS CONNECTING ON EACH | | | FLOOR? SEPARATE SHEETS SHALL BE | | | SUBMITTED FOR FLOOR PLANS THAT ARE NOT | | | TYPICAL. SECTION 104.2.1. | | | | | | 67B. SHT P2-06 NOT ALL VENTS ARE SHOWN | | | AS THRU THE ROOF. SOME VENTS CONNECTING | | | WITH OTHER VENTS AS SHOWN ON SHT P2-05 | | | DO NOT REFLECT WHAT IS SHOWN ON P2-06. | | | CORRELATE ALL VENTS AS THEY COME THRU | | | THE ROOF WITH THE FLOOR BELOW. ALL VENTS | | | SHALL BE SHOWN AS VTR. SECTION 104.2.1. | | | | | | 68B. SUBMIT WATER RISER DIAGRAMS FOR ALL | | | UNITS, (SHOWN ON SHTS P3-00 THRU P3-03), | | | SHOWING ALL PIPE SIZES, VALVES, AND | | | WATER HAMMER ARRESTORS, (REQUIRED BY | | | SECTION 604.9). WATER HAMMER ARRESTORS | | | SHALL BE LOCATED NEAR THE FIXTURE, IN AN | | | "EFFECTIVE RANGE", (NOT IN THE CEILING), | | | PER PDI-WH 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS. SECTION 104.3.1.1. | | | | | | 69B. SHT P4-00B RISER SV13 DOES NOT | | | REFLECT THE FLOOR PLAN. OFFSET NOT SHOWN | | | ON THE FLOOR PLAN AT THE 11TH FLOOR. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 70B. SHT P4-00B RISER SV17 IS NOT SHOWN | | | ON THE FIRST FLOOR. CORRELATE RISER AND | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | 71B. SHT P4-01A RISER P16 DOES NOT | | | REFLECT THE FLOOR PLAN. OFFSET NOT SHOWN | | | ON FLOOR PLAN. CORRELATE RISER AND FLOOR | | | PLAN. SECTION 104.2.1. | | | | | | 72B. SHT P4-03 SUBMIT WATER SUPPLY RISER | | | ISOMETRIC RISER DIAGRAMS FOR TOILET | | | ROOMS AND DRINKING FOUNTAIN. SECTION | | | 104.3.1.1. - WATER HAMMER ARRESTORS | | | SHALL BE LOCATED IN AN "EFFECTIVE RANGE" | | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | | AND MANUF. INSTALLATION INSTRUCTIONS. | | | | | | 73B. SHT P4-04 ROOF DRAIN STORM WATER | | | RISER. RECHECK THE PIPE SIZING, AS SOME | | | SIZES ARE INCORRECT PER TABLE 1106.3. - | | | RD3 SQUARE FOOTAGE DOES NOT REFLECT SF | | | SHOWN ON THE ROOF PLAN.- RD-11 IS SHOWN | | | AS 6", BUT IS SHOWN AS 4" ON THE ROOF | | | PLAN. CORRELATE RISER WITH FLOOR PLAN. | | | - RECHECK ADDITION FROM 10" (18656SF) | | | AND ALL DOWNSTREAM FIGURES. SECTION | | | 104.2.1. | | | | | | 74B. SHT P4-04B SOME PIPE SIZING IS | | | INCORRECT. ADDITION NEEDS TO BE CHECKED | | | FROM 8" (5960SF) AND DOWNSTREAM. SOME | | | AREA DRAINS ARE SHOWN AS PLANTER DRAINS | | | AND SOME PLANTER DRAINS ARE SHOWN AS | | | AREA DRAINS. CORRELATE RISER AND FLOOR | | | PLAN. SECTION 104.2.1 AND TABLE 1106.3. | | | | | | 75B. SHTS P4-05 & P4-06 THE CONDENSATE | | | AND EMERGENCY PAN DRAIN LINE FOR THE | | | WATER HEATER SHALL NOT BE COMBINED. PAN | | | DRAIN SHALL BE SEPARATE. SECTION | | | 504.8.2. | | | | | | 76B. SHT P4-06 CD18 DOES NOT REFLECT THE | | | FLOOR PLAN ON THE 1ST FLOOR. CORRELATE | | | RISER AND FLOOR PLAN. SECTION 104.2.1. | | | | | | | | | 77B. SHT P4-06 CD15 IS NOT SHOWN ON | | | FLOORS 1 THRU 5. PLEASE INDICATE WHERE | | | CD15 TERMINATES. SECTION 104.2.1. | | | | | | 78B. SHT P6-00 INDICATES TWO SUPPLY | | | LINES TO RISER W17. PLEASE CLARIFY. | | | SECTION 104.2.1. | | | | | | 79B. SUBMIT EMERGENCY PAN DRAIN LINE | | | RISERS FOR THE WATER HEATERS. SHOW ALL | | | PIPE SIZES, OFFSETS AND TERMINATION | | | POINT. SECTION 104.3.1.1. | | | | | | 80B. SUBMIT A HORIZONTAL ISOMETRIC RISER | | | DIAGRAM FOR THE BUILDING SANITARY DRAIN. | | | SHOW ALL PIPE SIZES, RISER CONNECTION | | | LOCATION, IDENTIFY RISER, AND SHOW DFU'S | | | AS THEY ACCUMULATE IN THE SYSTEM. | | | SECTION 104.3.1.1. | | | | | | 81B. SHT P2-05 KEYED NOTES ON FLOOR PLAN | | | BUT NO "PLUMBING KEYED NOTES INDEX" | | | SUBMITTED ON THE SHEET. SUBMIT KEYED | | | NOTES FOR THIS SHEET, MAKING SURE THEY | | | REFLECT THE KEYED NOTES SHOWN ON THE | | | FLOOR PLAN. SECTION 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-09-30 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-09-13 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2006-09-30 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 FUEL GAS | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FBC-2001 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | WPB CITY CODE | | | | | | FROM PREVIOUS REVIEW. COMMENT NUMBER TO | | | REMAIN THE SAME. | | | | | | 1. OK | | | 2. OK | | | 3. OK | | | 4. OK | | | | | | 5. SHT CD-11 DETAIL #1 CLEAR FLOOR SPACE | | | AT THE TOILET SHALL COMPLY WITH ONE OF 3 | | | SHOWN ON PAGE 7.43 FHA DESIGN MANUAL. | | | ***RESPONSE NOTED, BUT BOTH DIMENSIONS | | | SHALL BE SHOWN. | | | | | | 6. SHT CD-11 RESIDENTIAL UNIT | | | ACCESSIBLITY NOTES: | | | #7 OK | | | #8(II)(B)(V) CALLS FOR DETAIL 3/CD-4. | | | NO DETAIL 3 FOUND THAT SHEET. CLARIFY. | | | SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT IT NOW CALLS FOR | | | DETAIL 3/CD-11. THIS DETAIL DOES NOT | | | SHOW LAVS/VANITIES. SECTION 104.2.1. | | | | | | 7. OK | | | | | | 8. SHT CD-12 NOTES FOR W/C REFERENCE | | | DETAIL 3/CD-03.DETAIL NOT FOUND. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT IT ONLY SHOWS | | | DIMENSION 5'6". BOTH DIMENSIONS SHALL BE | | | SHOWN. PAGE 7.43. | | | | | | 9.OK | | | 10. OK | | | 11. OK | | | 12. OK | | | 13. OK | | | 14. OK | | | 15. OK | | | | | | 16. SHT A1-04 4TH FLOOR BALCONYS APPEAR | | | TO HAVE A PARAPET WALL ON ALL THREE | | | SIDES. SHT REFERENCES DETAIL 1/A6-05, | | | BUT SHT A6-05 WAS NOT SUBMITTED. SHT | | | ALSO REFERENCES DETAIL 11/A6.20 WHICH | | | SHOWS 1-1/2" WEEP HOLES. DRAINAGE PER | | | SECTIONS 1106 & 1107WILL BE REQUIRED | | | FOR STORM WATER IF A PARAPET WALL IS ON | | | ALL SIDES. PLEASE SUBMIT A DETAIL AND | | | CLARIFY. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT SCUPPERS SHALL BE | | | A MINIMUM 4" HIGH. SECTION 1503.4.2. THE | | | PEDESTRAIN TRAFFIC COATING IS INDICATED | | | AS 4" HIGH UP THE WALL ON DETAIL | | | 11/A6.20. THIS APPEARS TO COVER THE | | | SCUPPERS. PLEASE CLARIFY OR SUBMIT AN | | | ELEVATION DETAIL OF THE SCUPPERS. | | | SECTION 104.2.1. | | | | | | 17. SHTS A3-20, A3-21 SHOW DIMENSIONS OF | | | OPENINGS FOR EACH WATER CLOSET. MINIMUM | | | 33" OPENING REQUIRED. 18" OFF THE WALL | | | TO THE CENTER OF THE FIXTURE, AND | | | MINIMUM 15" TO THE NEXT FIXTURE. MINIMUM | | | 18" OFF ONE FIXTURE, AND 15" MINIMUM OFF | | | THE OTHER FIXTURE. FHA DESIGN MANUAL | | | PAGES 7.43, 7.44, 7.45, 7.46. | | | ***RESPONSE NOTED, BUT DETAILS 7 & 9 SHT | | | A3-20, (INDICATED AS 2ND DETAIL #5), AND | | | DETAILS 3 & 4 SHT A3-21, THE 18" FROM | | | THE CENTERLINE OF THE WATER CLOSET TO | | | THE WILL IS AN ABSOLUTE MEASUREMENT, NOT | | | A MINIMUM AS SHOWN. PAGE 6.5 FHA DESIGN | | | MANUAL. | | | | | | 18. N/A | | | 19. SHT A1-18 OVERFLOW SCUPPERS ARE | | | REQUIRED FOR THE UPPER ROOF. SECTION | | | 1106.5. SHOW LOCATION AND INDICATE SIZE | | | OF OVERFLOW SCUPPERS PER SECTION 1101.7, | | | 1107.3 AND TABLE 1106.7. | | | ***RESPONSE NOTED, BUT OVERFLOW SCUPPERS | | | ARE NOT INDICATED ON THE MECHANICAL ROOM | | | OR STAIRWELL ROOFS. SECTIONS 1107.1, | | | 1107.2 & 1107.3. | | | | | | 20. SHT AP1-06 SHOW THE LOCATION OF ALL | | | SECONDARY ROOF DRAINS. SECTION 1107. | | | ***RESPONSE NOTED, BUT THE SECONDARY | | | DRAINS ARE REQUIRED AT THE 6TH FLOOR | | | DECK AREA. PLEASE INDICATE THE LOCATION, | | | SIZE AND SQUARE FOOTAGE DRAINED BY EACH | | | SECONDARY DRAIN. SECTION 1107.1, 1107.2, | | | AND 1107.3. | | | | | | 21. SHT ID7-01 PER SECTION 1210.2 WALLS | | | WITHIN 2' OF A WATER CLOSET SHALL BE | | | NONABSORBENT UP TO 4'. PLANS INDICATE | | | THAT ONLY THE WALL BEHIND THE WATER | | | CLOSET HAS TILE. PLEASE INDICATE HOW THE | | | VINAL WALL PAPER COMPLYS WITH THE NON- | | | ABSORBENT REQUIREMENT. | | | ***RESPONSE NOTED, BUT A SUBMITTAL FOR | | | THE PRODUCT, WITH INSTALLATION | | | INSTRUCTIONS, SHALL BE SUBMITTED FOR | | | REVIEW AND APPROVAL. SECTION 104.2.1.2. | | | | | | 22. SHT ID8-01 DETAILS 1 & 2 SHOW THE | | | FOLLOWING ON THE DETAILS: | | | 11-4.16.2 CLEAR FLOOR SPACE (W/C) OK | | | 11-4.16.3 HEIGHT 9W/C) OK | | | | | | 11-4.16.5 FLUSH CONTROLS (W/C) NOT | | | ADDRESSED. | | | | | | 11-4.16.6 DISPENSERS (W/C) OK | | | | | | 11-4.19.2 HEIGHT & CLEARANCES (LAV) | | | CLEARANCES NOT ADDRESSED. | | | | | | 11-4.19.3 CLEAR FLOOR SPACE (LAV) OK | | | | | | 11-4.19.5 FAUCETS (LAV) NOT ADDRESSED | | | | | | 11-4.19.6 MIRRORS (LAV) OK | | | 11-4.22.3 5' TURNING AREA (TOILET ROOM) | | | OK | | | 23. OK | | | | | | 24. ALL PLUMBING SHEETS, ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME, ADDRESS, | | | AND LICENSE NUMBER ON EACH SHEET, AND IF | | | PRACTICING THROUGH A DULY AUTHORIZED | | | ENGINEERING BUSINESS, ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME AND LICENSE | | | NUMBER, AS WELL AS, THE NAME, ADDRESS, | | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | | OF THE ENGINEERING BUSINESS ON EACH | | | SHEET. FAC 61G15-23.002(2) & FS 471.2055 | | | ***RESPONSE NOTED, BUT LICENSE NUMBER IS | | | NOT IS NOT INDCATED. | | | | | | 25. OK | | | | | | 26. SHT P0-01 PLUMBING FIXTURE SCHEDULE, | | | SHOW ALL PIPE SIZES TO ALL WATER | | | HEATERS. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT EWH-3 | | | SPECIFICATION SHEET INDICATES 1-1/4" | | | OPENING FOR THE HOT & COLD WATER. | | | FIXTURE SCHEDULE INDICATES 1/2" COLD | | | WATER SUPPLY. PLEASE CORRELATE SUPPLY | | | SIZE PIPE FOR ALL HEATERS WITH MANUF. | | | SPECIFICATION FOR PIPE SIZE CONNECTIONS. | | | SECTION 104.2.1. | | | | | | 27. N/A | | | 28. N/A | | | 29. OK | | | 30. OK | | | 31. OK | | | 32. OK | | | 33. OK | | | 34. OK | | | 35. OK | | | | | | 36. SHT P2-00 NO KEYED NOTE FOR #5 | | | FOUND. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT KEY NOTE #1 WAS | | | CHANGED TO #3 ON THE FLOOR PLAN AND DOES | | | NOT REFLECT THE INFORMATION INDICATED IN | | | KEY NOTE. PLEASE CLARIFY SECTION | | | 104.2.1. | | | | | | 37. SHT P2-00 RD-21, SV2, SV3, SV-4, P1. | | | P2, P-3, CD-10 AND OTHER RISERS SHOWN ON | | | SHT P2-01 BUT NOT SHOWN ON THIS SHEET. | | | ALL RISERS START ON THE FIRST FLOOR AND | | | ALL RISERS LOCATIONS SHALL BE SHOWN | | | WHERE THEY START IN THE SYSTEM. | | | ***RESPONSE NOTED, BUT MANY RISER | | | NUMBERS CHANGE FROM FLOOR TO FLOOR ON | | | THE FLOOR PLAN. SOME RISERS ARE NOT | | | INDICIATED ON THE FIRST FLOOR, SOME | | | RISER DESIGNATIONS HAVE NO RISER | | | DIAGRAMS. SOME RISER START OFF AS ONE | | | RISER NUMBER, CHANGE TO ANOTHER RISER | | | NUMBER AND THEN CHANGE BACK TO THE | | | ORIGINAL NUMBER. PLEASE CORRELATE ALL | | | RISERS. SECTION 104.2.1. | | | | | | 38. EACH SANITARY RISER DIAGRAM, BE IT A | | | CONVENTIONAL SYSTEM OR A SOVENT SYSTEM | | | RISER SHALL HAVE ITS OWN RISER | | | DESIGNATION, SUCH AS P-1, P-2. P3 OR | | | SV-1, SV-2, SV-3 ETC. SHOWING MULTIPLE | | | RISERS WITH THE SAME RISER DESIGNATION | | | IS CONFUSING BECAUSE, (FOR EXAMPLE), NOT | | | ALL P-1 RISERS ARE THE SAME AS THE | | | PIPING IS NOT ALWAYS THE SAME AND THE | | | OFFSETS ARE NOT ALL THE SAME FOR EACH | | | P-1. SEE FOR EXAMPLE THE WATER RISERS, | | | THE CONDENSATE RISERS, OR THE STORM | | | RISERS. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT THE RISERS ARE | | | STILL CONFUSING. ALL SANTARY RISERS | | | SHOULD HAVE THERE OWN RISER NUMBER. | | | EXAMPLE SANT. 1, SANT. 2, SANT. 3 ETC. | | | EACH RISER CAN BE A TYPICAL OF A RISER | | | TYPE FOR EXAMPLE SV-4 OR P-4, BUT EACH | | | RISER WOULD BE ABLE TO BE LOCATED | | | INDIVIDUALLY, AND WHEN A COMMENT IS MADE | | | CONCERNING A SANT. RISER, IT WOULD BE | | | EASY TO UNDERSTAND WHICH RISER IS BEING | | | COMMENTED ON.SECTION 104.2.1. | | | | | | | | | 39. ALL SHEETS SHOWING PIPING ON FLOOR | | | PLANS: SHOW ALL PIPING INCLUDING ARMS TO | | | LAVS OR KITCHEN SINKS. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT NO PIPING IS | | | SHOWN FOR COMMON AREA TOILET ROOMS 104, | | | & 105. SECTION 104.2.1. | | | | | | 40. OK | | | | | | 41. SHT P2-01 RISERS RD-6, RD-9, RD-12 | | | AND RD-13 HAVE BEEN OFFSET, BUT NO | | | OFFSET PIPING IS SHOWN. PLEASE SHOW ALL | | | OFFSET PIPING ON PLANS. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT RD-6 RISER STILL | | | DOES NOT REFLECT THE FLOOOR PLAN. | | | SECTION 104.2.1. | | | | | | 42. SEE COMMENT 38. | | | 43. SEE COMMENT 38 | | | 44. SEE COMMENT 38 | | | 45. SEE COMMENT 38 | | | | | | 46. SHT P2-02 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW SQUARE FOOOTAGE BEING | | | DRAINED AT EACH PRIMARY DRAIN AND SHOW | | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS ADDED IN CALCULATIONS AS WELL | | | AS ANY AREAS FROM UPPER ROOFS ADDED TO | | | THE DECK AREA. | | | ***RESPONSE NOTED, BUT CALCULATIONS FOR | | | PRIMARY ROOF DRAINS AND FOR AREA DRAINS | | | FOR THE 6TH FLOOR TERRACE AREAS HAVE NOT | | | BEEN SUBMITTED. TABLE 1106.3 | | | | | | 47. SHT P2-02 MANY AREA DRAINS ARE | | | MISLABELED AS PLANTER DRAINS, MANY | | | DRAINS ARE NOT LABELED, MANY LABELS SHOW | | | NO DRAIN. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | ***RESPONSE NOTED, BUT SOME DRAINS ARE | | | STILL MISLABELED. SECTION 104.2.1. | | | | | | 48. OK | | | 49. SEE COMMENT 38 | | | 50. SEE COMMENT 38 | | | 51. SEE COMMENT 38 | | | 52. SEE COMMENT 38 | | | 53. SEE COMMENT 38 | | | 54. SEE COMMENT 38 | | | 55. SEE COMMENT 38 | | | 56. SEE COMMENT 38 | | | 57. SEE COMMENT 38 | | | 58. SEE COMMENT 38 | | | 59. SEE COMMENT 38 | | | 60. SEE COMMENT 38 | | | 61. SEE COMMENT 38 | | | 62. SEE COMMENT 38 | | | 63. SEE COMMENT 38 | | | 64. SEE COMMENT 38 | | | 65. SEE COMMENT 38 | | | 66. OK | | | 67. SEE COMMENT 38 | | | 68. SEE COMMENT 38 | | | 69. SEE COMMENT 38 | | | 70. SEE COMMENT 38 | | | 71. SEE COMMENT 38 | | | 72. SEE COMMENT 38 | | | 73. OK | | | 74. OK | | | 75. OK | | | | | | 76. SHT P2-06 THE VENTS THRU THE ROOF DO | | | NOT REFLECT THE VENTS SHOWN ON SHT P2-05 | | | FOR LOCATION. PLEASE CORRELATE VENTS | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT SOME VENTS ARE | | | NOT SHOWN OR DO NOT CONNECT TO OTHER | | | VENTS AS SHOWN BELOW. SECTION 104.2.1. | | | | | | 77. OK | | | 78. OK | | | 79. OK | | | 80. OK | | | 81. OK | | | 82. OK | | | 83. OK | | | 84. OK | | | 85. OK | | | | | | 86. SHT P4-00 ALL SV RISERS DO NOT | | | REFLECT THE FLOOR PLANS FOR THE FIRST | | | FLOOR PIPING. SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT THE SOME RISERS | | | DO NOT REFLECT THE FLOOR PLANS ON THE | | | FIRST FLOOR, OR AT THE OFFSETS. SOME | | | RISERS REFLECT THE FLOOR PLANS IN ONE | | | INSTANCE, BUT THE FLOOR PLAN CHANGES FOR | | | THE SAME RISER IN ANOTHER INSTANCE. | | | RISER CAN NOT BE TYPICAL IF NOT EXACTLY | | | THE SAME IN EACH CASE. SECTION 104.2.1. | | | | | | 87. SHT P4-00 ALL SV RISERS DO NOT | | | REFLECT THE FLOOR PLANS FOR THE 16TH | | | FLOORS. NO VENT PIPING SHOWN FOR THE | | | REVENTS SHOWN ON THE 16TH FLOOR. SECTION | | | 106.1.1. | | | ***RESPONSE NOTED, BUT FOR EXAMPLE THE | | | VENTS P1/P19/SV-13/SV-1 ARE CONNECTED | | | TOGETHER ON THE FLOOR PLAN, BUT THE VTR | | | ON THE ROOF PLAN DOES NOT SHOW THIS. | | | SV-13 DOES NOT INDICATE CONNECTING TO | | | SV-1. P19 OFFSET VENT BUT DOES NOT | | | INDICATE TO WHICH VENT STACK. THIS IS | | | EVEN MORE OF A PROBLEM WHEN THERE ARE | | | MORE THAN ONE RISER FOR A RISER | | | DESIGNATION. (SEE COMMENT 38). | | | | | | 88.OK | | | | | | 89. SHT P4-00 16TH FLOOR SHALL BE | | | DIFFERENT FROM OTHER FLOOR ON ALL RISERS | | | AS THE VENTING/REVENTING IS ONLY ON THIS | | | FLOOR. SHOW ALL VENTING/REVENTING ON | | | RISERS. (THIS IS REQUIRED FOR ALL VENTS | | | INCLUDING SOVENT SYSTEM IF VENTS FROM | | | OTHER STACKS ARE TYING INTO THEM. | | | SECTION 106.1.1. | | | ***RESPONSE NOTED, BUT SOME FLOORS ARE | | | NOT TYPICAL AND INDIVIDUAL FLOORS FOR | | | THE FLOORS THAT ARE NOT TYPICAL SHALL BE | | | SUBMITTED SEPARATELY. | | | | | | 90. OK | | | 91. OK | | | | | | 92. SEE COMMENT 38 | | | | | | 93. SHT P4-00 SUBMIT A RISER DIAGRAM FOR | | | EACH SANTITARY RISER DIAGRAM AND EACH | | | SOVENT RISER DIAGRAM. COMMON RISERS WITH | | | DIFFERENT FLOOR PLANS ARE NOT | | | ACCEPTABLE. IF THE TUB AND LAV ARE ON | | | THE OPPOSITE SIDE OF THE WATER CLOSET | | | FROM ONE FLOOR PLAN TO THE OTHER, OR | | | OFFSETS ARE DIFFERENT, OR ON DIFFERENT | | | FLOOR PLANS, THEN SEPARATE RISER | | | DIAGRAMS ARE REQUIRED. RISER DIAGRAMS | | | SHALL REFLECT THE FLOOR PLAN FROM THEIR | | | CONNECTION TO THE BUILDING DRAIN UP THRU | | | THE ROOF FOR VENTING. BECAUSE THIS IS AN | | | ENGINEERED SYSTEM, SEPARATE RISERS ARE | | | REQUIRED, AND SEPARATE RISER | | | DESIGNATIONS ARE REQUIRED. SOME RISERS | | | CHANGE RISER NUMBERS FROM FLOOR TO FLOOR | | | PLEASE CLARIFY. FLOOR PLANS SHOW REVENTS | | | FROM OTHER RISERS TYING TOGETHER PRIOR | | | TO VENTING THRU THE ROOF. THIS IS NOT | | | REFLECTED ON ANY OF THE RISER DIAGRAMS. | | | ***RESPONSE NOTED, BUT PROBLEM NOT | | | ADDRESSED. SEE COMMENT 38. | | | | | | 94. SUBMIT AN APPROVED DESIGN MANUAL FOR | | | THE SOVENT SYSTEM. SUBMIT MANUFACTURE | | | SPECIFICATIONS FOR AERATORS AND | | | DEAERATORS FOR PRODUCT APPROVAL PER | | | SECTIONS 303.1 & 303.4. | | | ***COMMENT NOT ADDRESSED. NO RESPONSE. | | | | | | | | | 95. PLANS APPEAR TO BE INCOMPLETE AT | | | THIS TIME, AS ALL THE SV RISERS ARE NOT | | | SUBMITTED AS WELL AS THE BLDG DRAIN FOR | | | OTHER SYSTEMS. OTHER COMMENTS MAY OR MAY | | | NOT FOLLOW UPON SUBMITTAL OF REQUIRED | | | INFORMATION AND INFORMATION NOT | | | SUBMITTED AT THIS TIME. SECTIONS 106.1.1 | | | AND 106.3.5.1.3. | | | ***RESPONSE NOTED, BUT PLANS DO NOT SEEM | | | TO BE COMPLETE YET. (SEE NEW COMMENTS) | | | | | | 96. SHT P4-01 ALL STACKS, RELIEF VENTS | | | ARE REQUIRED PER SECTION 914.1 AND SHALL | | | BE PROVIDED AT EACH 10TH INTERVAL | | | BEGINNING WITH THE TOP FLOOR. SECTION | | | 914.1. | | | ***RESPONSE NOTED, BUT THE STACKS WITH | | | VENT STACKS REQUIRE RELIEF VENTS PER | | | SECTION 914.1 HAS NOT BEEN ADDRESSED. | | | | | | 97. OK | | | 98. OK | | | 99. OK | | | | | | 100. SHT P4-02 RISERS W1, W2, W6, W8, & | | | W10 FULL OPEN VALVES SHALL BE INSTALLED | | | ON THE BASE OF EVERY WATER RISER PIPE. | | | SECTION 606.1(3). | | | ***RESPONSE NOTED, BUT W8 RISER STILL | | | SHOWS NO VALVE. | | | | | | 101. SHT P4-04 SUBMIT THE BUILDING STORM | | | DRAIN IN AN ISOMETRIC RISER DIAGRAM THAT | | | REFLECTS THE PIPING SHOWN ON THE | | | UNDERGROUND PLUMBING PLAN SHT P2-00. | | | SECTION 106.3.5.1.3. SHOW ALL PIPE SIZES | | | AND SQUARE FOOTAGE AS IT ACCUMULATES IN | | | THE SYSTEM. IDENTIFY ALL RISERS AS THEY | | | CONNECT TO THE BUILDING DRAIN IN THE | | | ISOMETRIC DIAGRAM OF THE BUILDING DRAIN. | | | SHOW ALL OFFSETS IN THE STORM RISERS, | | | AND INDICATE ALL PIPE SIZES. | | | ***RESPONSE NOTED, BUT RISER NUMBER ARE | | | NOT SHOWN TO IDENTIFY RISERS. (EXAMPLE | | | RWL-1, RWL-2 ETC.). SECTION 104.2.1. | | | | | | 102. SHTS P4-05 & P4-06 INDICATE | | | MATERIAL FOR CONDENSATE SYSTEM. NO | | | FLAMABLE MATERIAL IN THE AIR CONDITION | | | ROOM IF IT IS USED AS A PLENUM. INDICATE | | | METHOD OF VENTING THE CONDENSATE RISERS. | | | VENTS CAN NOT TERMINATE IN THE WALLS OR | | | IN A PLENUM. | | | ***RESPONSE NOTED, BUT THE MATERIAL FOR | | | THE CONDENSATE SYSTEM WAS NOT FOUND ON | | | SHT P0-01. SECTION 104.2.1. | | | | | | 103. SHTS P4-05 & P4-06 SUBMIT A | | | BUILDING DRAIN CONDENSATE ISOMETRIC | | | RISER DIAGRAM THAT REFLECTS THE | | | UNDERGROUND PIPING ON SHT P2-00. SECTION | | | 106.3.5.1.3. | | | ***RESPONSE NOTED, BUT THE HORIZONTAL | | | BUILDING DRAIN FOR THE CONDENSATE IS | | | REQUIRED BY SECTION 104.3.1.1. THE | | | CONDENSATE AND THE WATER HEATER PAN | | | DRAIN LINE CAN NOT BE COMBINED. SEPARATE | | | DRAIN LINES AND SYSTEMS ARE REQUIRED. | | | SECTION 504.8.2. | | | | | | 104. SHT P5-00 DETAIL 05 WASHER BOX | | | CONNECTION WATER HAMMER ARRESTORS ARE | | | REQUIRED AT THE WASHER BOX PER 604.9. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES IN AN "EFFECTIVE | | | RANGE" NOT IN THE CEILING. PDI-WH 201 | | | AND MANUF. INSTALLATION INSTRUCTIONS. | | | ***RESPONSE NOTED, BUT WATER HAMMER | | | ARRESTORS ARE NOT SHOWN. SECTION | | | 104.2.1. | | | | | | 105. OK | | | 106. OK | | | | | | 107. SHT P5-00 DETAIL 04 WATER HEATER | | | SUBMIT EMERGENCY PAN DRAIN ISOMETRIC | | | RISER DIAGRAM SHOWING ALL PIPE SIZES, | | | MATERIAL, AND TERMINATION POINT. SECTION | | | 106.3.5.1.3. | | | ***RESPONSE NOTED, BUT RESPONSE DID NOT | | | ADDRESS COMMENT. SECTION 104.3.1.1. | | | | | | 108. OK | | | | | | 109. SHT P5-00 DETAIL 07 DOMESTIC WATER | | | BOOSTER PUMP DETAIL: SUBMIT MANUF. | | | SPECIFICATION SHEETS FOR PUMP. PUMP | | | SHALL BE LISTED. SECTION 303.4. | | | ***RESPONSE NOTED, BUT RESPONSE NEEDS TO | | | BE CLARIFIED. SCHEDULED PUMP? | | | | | | 110. OK | | | 111. OK | | | 112. OK | | | | | | 113. ALL SETS OF PLANS AND ALL SHEETS IN | | | EACH SET OF PLANS: IF THE DESIGN | | | PROFESSIONAL IS AN ENGINEER, THEN HE OR | | | SHE SHALL AFFIX HIS OR HER OFFICIAL | | | SEAL, SIGNATURE AND DATE TO SAID | | | DRAWINGS AS REQUIRED BY FLORIDA | | | STATUTES. NO INITIALS. LEGAL SIGNATURE | | | IS REQUIRED. | | | ***RESPONSE NOTED, BUT INITIALS APPEAR | | | TO BE SUBMITTED IN PLACE OF A SIGNATURE. | | | IF THIS IS THE LEGAL SIGNATURE, PLEASE | | | SUBMIT A SIGNED, SEALED, DATED, | | | NOTORIZED LETTER INDICATING LEGAL | | | SIGNATURE FOR OUR FILES. FAC | | | 61G15-23.002(2) AND FS | | | 471.025. | | | | | | 114. SUBMIT WATER ISOMETRIC RISER | | | DIAGRAMS FOR EACH UNIT SHOWING ALL PIPE | | | SIZES, VALVES, AND WATER HAMMER | | | ARRESTORS REQUIRED BY SECTION 604.9. | | | SECTION 106.3.5.1.3. | | | ***RESPONSE NOTED, BUT RESPONSE HAS | | | NOTHING TO DO WITH COMMENT INFORMATION | | | REQUESTED. SECTION 104.3.1.1. | | | | | | 115. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS APPLICATION: | | | | | | ***DUE TO THE FACT THAT THERE ARE NOT | | | APPROVED GAS PLANS FROM PHASE I, THE | | | INFORMATION IS STILL REQUIRED.*** | | | | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGHTS PER FBC-2004 | | | FUEL GAS. | | | ***RESPONSE NOTED, BUT CORRESPONDING | | | LENGTHS NOT SHOWN. FBC-2001 FUEL GAS. | | | | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | ***RESPONSE NOTED, BUT INFORMATION SHALL | | | BE LOCATED AT RISER WITH REQUIRED INFO. | | | SECTION 104.2.1. | | | | | | C. TYPE OF GAS, (LP OR NATURAL). | | | ***RESPONSE NOTED, INFORMATION REQUIRED | | | ON PLANS WITH RISER. | | | | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | ***RESPONSE NOTED, BUT TOTAL BTU LOAD OF | | | SYSTEM NOT SHOWN. INFORMATION REQUIRED | | | ON PLANS WITH RISER. | | | | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | ***NO RESPONSE NOT ADDRESSED. | | | | | | F. NA | | | | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. IF | | | 2 PSI INDICATE LOCATION OF REGULATORS | | | AND SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR REGULATORS INDICATING MODEL. IF | | | VENTED REGULATORS, INDICATE MATERIAL FOR | | | VENTS AND SHOW ROUTING OF PIPING. | | | ***NO RESPONSE, NOT ADDRESSED. | | | | | | H. NA | | | | | | I. SUBMIT MANUFACTURE SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | ***NO RESPONSE, NOT ADDRESSED. | | | | | | J. N/A | | | K. N/A | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE RESUBMIT RED LINED SET OF | | | PLUMBING PLANS FROM FIRST REVIEW TO HELP | | | TO EXPEDITE THE SECOND REVIEW. | | | ***NO RESPONSE, NOT ADDRESSED ADDING | | | MANY HOURS TO REVIEW. RED LINED SET OF | | | PLUMBING PLANS TO BE RETAINED TO | | | EXPEDITE NEXT REVIEW. | | | | | | END OF COMMENTS FROM FIRST REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-25 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-02-25 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-02-22 |
Time |
18:27 |
Sent To |
|
|
| Notes |
| 2006-02-25 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | WPB CITY CODE | | | | | | 1. ALL "CS", "CD" AND ARCHITECTURAL | | | SHEETS SHALL BE DATED WHEN THE SEAL AND | | | SIGNATURE ARE AFFIXED TO THE DOCUMENT. | | | FAC 61G1-16.003, 61G1-16.004(5) AND FS | | | 481.2055. | | | 2. SHT CD-10 APPLICABLE CODES INDICATE | | | 2001-FBC. CURRENT CODES IN EFFECT ARE | | | FBC-2004 AND PLANS ARE TO BE DESIGNED | | | PER THIS CODE. PLEASE INDICATE ON PLANS. | | | 3. SHT CD-10 SCUPPERS TO BE SIZED PER | | | SECTIONS 1101.7, 1107.3 AND TABLE | | | 1106.7. PLEASE INDICATE THIS ON THE | | | PLANS AND THE SIZING OF THE SCUPPERS CAN | | | NOT BE DETERMINED WITH OUT REFERENCE TO | | | THE DEFLECTION OF THE ROOF. | | | 4. SHT CD-11 BACKING FOR SHOWERS ARE TO | | | BE PER PAGE 6.12 FHA DESIGN MANUAL. SHOW | | | ALL 3 SIDES, (ELEVATIONS) OF THE SHOWER, | | | AND BACKING SHALL BE SIDE TO SIDE EACH | | | ELEVATION. | | | 5. SHT CD-11 DETAIL #1 CLEAR FLOOR SPACE | | | AT THE TOILET SHALL COMPLY WITH ONE OF 3 | | | SHOWN ON PAGE 7.43 FHA DESIGN MANUAL. | | | 6. SHT CD-11 RESIDENTIAL UNIT | | | ACCESSIBLITY NOTES: | | | #7 CALLS FOR DETAIL 2/A-6.11. SHT | | | A-6.11 HAS NOT BEEN SUBMITTED. CLARIFY. | | | SECTION 106.1.1. | | | #8(II)(B)(V) CALLS FOR DETAIL 3/CD-4. | | | NO DETAIL 3 FOUND THAT SHEET. CLARIFY. | | | SECTION 106.1.1. | | | 7. SHT CD-12 NOTES FOR BATHROOM | | | REFERENCE DETAIL 4/CD-05. THIS SHEET HAS | | | NOT BEEN SUBMITTED. PLEASE CLARIFY. | | | SECTION 106.1.1. | | | 8. SHT CD-12 NOTES FOR W/C REFERENCE | | | DETAIL 3/CD-03.DETAIL NOT FOUND. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | 9. SHT CD-12 DETAIL 2 UNIT TYPE A2, | | | U-SHAPED KITCHEN REQUIRES A 5' TURNING | | | AREA. SEE PAGE 7.9 FHA DESIGN MANUAL. | | | 10. SHT CD-13 DETAIL 2 UNIT TYPE D3, | | | SHOWER CLEAR FLOOR SPACE SHALL BE | | | PARALLEL AND FLUSH WITH THE CONTROL | | | WALL. PAGE 7.56 FHA DESIGN MANUAL. | | | 11. SHT CD-14 DETAIL 5 UNIT TYPE P3, A | | | U-SHAPED KITCHEN REQUIRES A 5' DIA. | | | TURNING AREA. PAGE 7.9 FHA DESIGN | | | MANUAL. | | | 12. SHT CD-14 UNIT TYPE P1 DETAIL 3 LAV | | | WITH FORWARD APPROACH TO HAVE REMOVABLE | | | BASE CABINET. PAGES 7.49, 7.50, AND 7.51 | | | FHA DESIGN MANUAL. SUBMIT A DETAIL. | | | 13. SHT CD-14 UNIT TYPE P1 DETAIL 3 | | | U-SHAPED KITCHEN REQUIRES A 5' DIAMETER | | | TURNING AREA. PAGE 7.9 FHA DESIGN MAN. | | | 14. SHT CD-14 DETAIL 1 UNIT TYPE G1A | | | SHOWER CLEAR FLOOR SPACE SHALL BE | | | PARALLEL TO SHOWER AND FLUSH WITH THE | | | CONTROL WALL. PAGE 7.56 FHA DESIGN MAN. | | | 15. SHTS CD-12, CD-13, CD-14 ALL UNITS, | | | SPECIFICATION "A" OR "B" REQUIRED TO BE | | | SHOWN ON EACH UNIT/BATHROOM. FHA DESIGN | | | MANUAL PAGES 7.34, 7.35. | | | 16. SHT A1-04 4TH FLOOR BALCONYS APPEAR | | | TO HAVE A PARAPET WALL ON ALL THREE | | | SIDES. SHT REFERENCES DETAIL 1/A6-05, | | | BUT SHT A6-05 WAS NOT SUBMITTED. SHT | | | ALSO REFERENCES DETAIL 11/A6.20 WHICH | | | SHOWS 1-1/2" WEEP HOLES. DRAINAGE PER | | | SECTIONS 1106 & 1107WILL BE REQUIRED | | | FOR STORM WATER IF A PARAPET WALL IS ON | | | ALL SIDES. PLEASE SUBMIT A DETAIL AND | | | CLARIFY. SECTION 106.1.1. | | | 17. SHTS A3-20, A3-21 SHOW DIMENSIONS OF | | | OPENINGS FOR EACH WATER CLOSET. MINIMUM | | | 33" OPENING REQUIRED. 18" OFF THE WALL | | | TO THE CENTER OF THE FIXTURE, AND | | | MINIMUM 15" TO THE NEXT FIXTURE. MINIMUM | | | 18" OFF ONE FIXTURE, AND 15" MINIMUM OFF | | | THE OTHER FIXTURE. FHA DESIGN MANUAL | | | PAGES 7.43, 7.44, 7.45, 7.46. | | | 18. SHT A1-17 OVERFLOW SCUPPERS SHALL BE | | | SIZED PER FBC-2004 PLUMBING SECTIONS | | | 1101.7, 1107.3 AND TABLE 1106.7. THE | | | SIZING OF THE SCUPPERS CAN NOT BE | | | DETERMINED WITH OUT REFERENCE TO THE | | | DEFLECTION OF THE ROOF. PLEASE PROVIDE | | | CALCULATION AND SHOW COMPLIANCE WITH | | | ABOVE SECTIONS AND TABLE ON PLANS | | | INDICATING THE SIZE OF THE SCUPPERS. | | | 19. SHT A1-18 OVERFLOW SCUPPERS ARE | | | REQUIRED FOR THE UPPER ROOF. SECTION | | | 1106.5. SHOW LOCATION AND INDICATE SIZE | | | OF OVERFLOW SCUPPERS PER SECTION 1101.7, | | | 1107.3 AND TABLE 1106.7. | | | 20. SHT AP1-06 SHOW THE LOCATION OF ALL | | | SECONDARY ROOF DRAINS. SECTION 1107. | | | 21. SHT ID7-01 PER SECTION 1210.2 WALLS | | | WITHIN 2' OF A WATER CLOSET SHALL BE | | | NONABSORBENT UP TO 4'. PLANS INDICATE | | | THAT ONLY THE WALL BEHIND THE WATER | | | CLOSET HAS TILE. PLEASE INDICATE HOW THE | | | VINAL WALL PAPER COMPLYS WITH THE NON- | | | ABSORBENT REQUIREMENT. | | | 22. SHT ID8-01 DETAILS 1 & 2 SHOW THE | | | FOLLOWING ON THE DETAILS: | | | 11-4.16.2 CLEAR FLOOR SPACE (W/C) | | | 11-4.16.3 HEIGHT 9W/C) | | | 11-4.16.5 FLUSH CONTROLS (W/C) | | | 11-4.16.6 DISPENSERS (W/C) | | | 11-4.19.2 HEIGHT & CLEARANCES (LAV) | | | 11-4.19.3 CLEAR FLOOR SPACE (LAV) | | | 11-4.19.5 FAUCETS (LAV) | | | 11-4.19.6 MIRRORS (LAV) | | | 11-4.22.3 5' TURNING AREA (TOILET ROOM) | | | 23. SHT ID10-01 FLOOR COVERING SCHEDULE | | | DOES NOT INDICATE MEN'S OR WOMEN'S | | | RESTROOMS. - WALL COVERING SCHEDULE | | | (REMARK) INDICATE WHAT A "WET WALL" IS. | | | - BASE SCHEDULE (WB-2) INDICATE HOW | | | SEMI-GLOSS PAINT MEETS THE NONABSORBENT | | | REQUIREMENT FOR MEN'S AND WOMEN'S TOILET | | | ROOMS. SECTION 1210.2. | | | 24. ALL PLUMBING SHEETS, ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME, ADDRESS, | | | AND LICENSE NUMBER ON EACH SHEET, AND IF | | | PRACTICING THROUGH A DULY AUTHORIZED | | | ENGINEERING BUSINESS, ENGINEERS SHALL | | | LEGIBLY INDICATE THEIR NAME AND LICENSE | | | NUMBER, AS WELL AS, THE NAME, ADDRESS, | | | AND CERTIFICATE OF AUTHORIZATION NUMBER | | | OF THE ENGINEERING BUSINESS ON EACH | | | SHEET. FAC 61G15-23.002(2) & FS 471.2055 | | | 25. SHT P0-01 REFERENCES FBC-2001. | | | ADOPTED CODE IS FBC-2004. PLEASE DESIGN | | | PER FBC-2004 AND CHANGE REFERENCE. | | | 26. SHT P0-01 PLUMBING FIXTURE SCHEDULE, | | | SHOW ALL PIPE SIZES TO ALL WATER | | | HEATERS. SECTION 106.1.1. | | | 27. SHT P0-01 DOMESTIC WATER FIXTURE | | | UNIT LOAD CALCS. REFER TO FBC-2001. | | | PLEASE CALCULATE PER ADOPTED CODE WHICH | | | IS FBC-2004. | | | 28. SHT P0-01 PLUMBING GENERAL NOTES | | | REFERENCES UPC-2000. SHOULD REFERENCE | | | FBC-2004. | | | 29. SHT P0-01 PLUMBING GENERAL NOTES | | | UNDER PIPING & MATERIALS: UNABLE TO READ | | | 3RD SECTION, LINE 5, WORDS SUPERIMPOSED | | | ON TOP OF EACH OTHER. SECTION 106.1.1. | | | 30. SHT P2-00 RAIN/STORM TO TRASH ROOM? | | | PLEASE CLARIFY. SECTION 106.1.1. | | | 31 SHT P2-00 SV8 IS NOT CONNECTED TO THE | | | BUILDING DRAIN. 106.1.1. | | | 32. SHT P2-00 CD-21 PIPED TO STORM? | | | PLEASE CLARIFY. SECTION 106.1.1. | | | 33. SHT P2-00 SV2 IS NOT CONNECT TO THE | | | BUILDING DRAIN. 106.1.1. | | | 34. SHT P2-00 CD-1 DESIGNATOR IS | | | POINTING TO A SANITARY RISER. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | 35. SHT P2-00 RD-3 CONNECTING TO THE | | | SANITARY SYSTEM. THIS IS NOT APPROVED | | | PER CITY CODE SECTION 90-125(5). | | | 36. SHT P2-00 NO KEYED NOTE FOR #5 | | | FOUND. SECTION 106.1.1. | | | 37. SHT P2-00 RD-21, SV2, SV3, SV-4, P1. | | | P2, P-3, CD-10 AND OTHER RISERS SHOWN ON | | | SHT P2-01 BUT NOT SHOWN ON THIS SHEET. | | | ALL RISERS START ON THE FIRST FLOOR AND | | | ALL RISERS LOCATIONS SHALL BE SHOWN | | | WHERE THEY START IN THE SYSTEM. | | | 38. EACH SANITARY RISER DIAGRAM, BE IT A | | | CONVENTIONAL SYSTEM OR A SOVENT SYSTEM | | | RISER SHALL HAVE ITS OWN RISER | | | DESIGNATION, SUCH AS P-1, P-2. P3 OR | | | SV-1, SV-2, SV-3 ETC. SHOWING MULTIPLE | | | RISERS WITH THE SAME RISER DESIGNATION | | | IS CONFUSING BECAUSE, (FOR EXAMPLE), NOT | | | ALL P-1 RISERS ARE THE SAME AS THE | | | PIPING IS NOT ALWAYS THE SAME AND THE | | | OFFSETS ARE NOT ALL THE SAME FOR EACH | | | P-1. SEE FOR EXAMPLE THE WATER RISERS, | | | THE CONDENSATE RISERS, OR THE STORM | | | RISERS. SECTION 106.1.1. | | | 39. ALL SHEETS SHOWING PIPING ON FLOOR | | | PLANS: SHOW ALL PIPING INCLUDING ARMS TO | | | LAVS OR KITCHEN SINKS. SECTION 106.1.1. | | | 40. ALL SHEETS RESEALED AND RESUBMITTED | | | SHALL CONTAIN THE NEW TYPE SEAL REQUIRED | | | AFTER DECEMBER 31 2005. SEE ATTACHED | | | SHEET FROM THE FLORIDA BOARD OF | | | PROFESSIONAL ENGINEERS. | | | 41. SHT P2-01 RISERS RD-6, RD-9, RD-12 | | | AND RD-13 HAVE BEEN OFFSET, BUT NO | | | OFFSET PIPING IS SHOWN. PLEASE SHOW ALL | | | OFFSET PIPING ON PLANS. SECTION 106.1.1. | | | 42. SHT P2-01 19 RISERS SHOWN ON THIS | | | SHEET WERE NOT SHOWN ON SHEET P2-00. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | 43. SHT P2-01 RISER P-1 IS SHOWN AS | | | RISER P-3 ON SHT P2-00. PLEASE CORRELATE | | | RISERS FROM FLOOR LEVEL TO FLOOR LEVEL. | | | SECTION 106.1.1. | | | 44. SHT P2-02 24 RISERS SHOWN ON THIS | | | SHEET WERE NOT SHOWN ON SHT P2-01. | | | PLEASE CORRELATE RISERS FROM FLOOR TO | | | FLOOR. SECTION 106.1.1. | | | 45. SHT P2-02 RISER P-4 IS SHOWN AS | | | RISER P-3 ON SHT P2-01. PLEASE CORRELATE | | | RISERS FROM FLOOR TO FLOOR. SECTION | | | 106.1.1. | | | 46. SHT P2-02 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW SQUARE FOOOTAGE BEING | | | DRAINED AT EACH PRIMARY DRAIN AND SHOW | | | 1/2 AREA OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS ADDED IN CALCULATIONS AS WELL | | | AS ANY AREAS FROM UPPER ROOFS ADDED TO | | | THE DECK AREA. | | | 47. SHT P2-02 MANY AREA DRAINS ARE | | | MISLABELED AS PLANTER DRAINS, MANY | | | DRAINS ARE NOT LABELED, MANY LABELS SHOW | | | NO DRAIN. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | 48. SHT P2-02 RISER CV-18 HAS BEEN | | | OFFSET FROM SHEET P2-01, BUT NO OFFSET | | | PIPING IS SHOWN ON THE FLOOR PLAN. | | | PLEASE CORRELATE PIPING FROM FLOOR TO | | | FLOOR. SECTION 106.1.1. | | | 49. SHT P2-03 RISERS P-4 & CD-19 SHOWN | | | ON THIS SHEET WERE NOT SHOWN ON SHEET | | | P2-02. PLEASE CORRELATE RISERS FROM | | | FLOOR TO FLOOR. SECTION 106.1.1. | | | 50. SHT P2-03 RISER SV-19 SHOWN AS SV-3 | | | ON SHEET P2-02. CORRELATE RISERS FROM | | | FLOOR TO FLOOR. SECTION 106.1.1. | | | 51. SHT P2-03 RISER P-6 SHOWN AS P-5 ON | | | SHT P2-02. CORRELATE RISERS FROM FLOOR | | | TO FLOOR. SECTION 106.1.1. | | | 52. SHT P2-03 RISER SV-1 SHOWN AS SV-7 | | | ON SHT P2-02. PLEASE CORRELATE RISERS | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | 53. SHT P2-03 RISER CD-19 IS SHOWN AS | | | CD-14 ON SHT P2-02. PLEASE CORRELATE | | | RISERS FROM FLOOR TO FLOOR. SECTION | | | 106.1.1. | | | 54. SHT P2-03 RISER CD-4 SHOW AS CD-13 | | | ON SHT P2-02. PLEASE CORREATE RISERS | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | 55. SHT P2-03 RISER CD-3 SHOWN AS CD-12 | | | ON SHT P2-02. PLEASE CORRELATE RISER | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | 56. SHT P2-03 RISER CD-2 SHOWN AS CD-11 | | | ON SHT P2-02. PLEASE CORRELATE RISERS | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | 57. SHT P2-03 RISER P-5 SHOWN AS P-6 ON | | | SHT P2-02. PLEASE CORRELATE RISERS FROM | | | FLOOR TO FLOOR. SECTION 106.1.1. | | | 58. SHT P2-03 RISER CV-13 SHOWN AS RISER | | | CV-1 ON SHT P2-02. PLEASE CORRELATE | | | RISERS FROM FLOOR TO FLOOR. SECTION | | | 106.1.1. | | | 59. SHT P2-03 RISERS P-4, P-5, RD5, | | | SV-11, AND SV-15. PLANS INDICATE THESE | | | RISERS HAVE BEEN OFFSET. NO PIPING FOR | | | OFFSETS HAS BEEN SHOWN ON THE FLOOR | | | PLAN. PLEASE SHOW ALL OFFSET PIPING ON | | | THE FLOOR PLANS. RISER DIAGRAMS SHALL | | | REFLECT ALL OFFSETS. SECTION 106.1.1. | | | 60. SHT P2-04 RISER P-6 SHOWN AS RISER | | | P-5 ON SHT PD2.03. PLEASE CORRELATE | | | RISERS FROM FLOOR TO FLOOR. SECTION | | | 106.1.1. | | | 61. SHT P2-04 RISERS P-9, (2 OF THEM), | | | ARE NOT SHOWN ON SHT P2-03. PLEASE | | | CORRELATE RISERS FROM FLOOR TO FLOOR. | | | SECTION 106.1.1. | | | 62. SHT P2-04 RISER P-8 NOT SHOWN ON SHT | | | P2-03. PLEASE CORRELATE RISERS FROM | | | FLOOR TO FLOOR . SECTION 106.1.1. | | | 63. SHT P2-04 RISER P-? DOES NOT HAVE A | | | RISER DESIGNATION NUMBER. PLEASE CLARIFY | | | SECTION 106.1.1. | | | 64. SHT P2-04 RISERS SV-1, SV-7, SV-13, | | | SV-14, & CD-2 HAVE BEEN OFFSET, BUT NO | | | OFFSET PIPING IS SHOWN ON THE FLOOR | | | PLAN. PLEASE SHOW ALL OFFSET PIPING ON | | | THE FLOOR PLAN, AND RISER DIAGRAMS SHALL | | | REFLECT THESE OFFSETS. SECTION 106.1.1. | | | 65. SHT P2-04 RISERS P-7, (TWO OF THEM), | | | ARE NOT SHOWN ON SHT P2-03. PLEASE | | | CORRELATE RISERS FROM FLOOR TO FLOOR. | | | SECTION 106.1.1. | | | 66. SHT P2-04 RISER AND PIPING NOT SHOWN | | | FOR BATHROOM GROUP IN UNIT P1. PLEASE | | | SHOW RISER AND INDICATE RISER NUMBER, | | | SHOW ALL PIPING. SECTION 106.1.1. | | | 67. SHT P2-05 RISER SV-1 SHOWN AS SV-3 | | | ON SHT P2-04. PLEASE CORRELEATE ALL | | | RISERS FROM FLOOR TO FLOOR. SECTION | | | 106.1.1. | | | 68. SHT P2-05 RISER SV-9 SHOWN AS SV-1 | | | ON SHT P2-04. PLEASE CORRELATE RISERS | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | 69. SHT P2-05 RISER SV-1 SHOWN AS SV-20 | | | ON SHT P2-04. PLEASE CORRELATE RISERS | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | 70. SHT P2.05 RISER P-3 SHOWN AS P-4 ON | | | SHT P2-04. PLEASE CORRELATE RISERS FROM | | | FLOOR TO FLOOR. SECTION 106.1.1. | | | 71. SHT P2-05 RISER SV-4 IS SHOWN AS | | | SV-1 ON SHT P2-04. PLEASE CORRELATE | | | RISERS FROM FLOOR TO FLOOR. SECTION | | | 106.1.1. | | | 72. SHT P2-05 RISER SV-2 IS SHOWN AS | | | SV-7 ON SHT P2-04. PLEASE CORRELATE | | | RISERS FROM FLOOR TO FLOOR. SECTION | | | 106.1.1. | | | 73. SHT P2-05 NO PIPING OR RISER SHOWN | | | FOR BATHROOM FIXTURES IN UNIT P1. PLEASE | | | SHOW PIPING AND RISER. INDICATE RISER | | | NUMBER. SECTION 106.1.1. | | | 74. SHT P2-05 SHEET TITLE DOES NOT | | | INCLUDE 15TH FLOOR AS INDICATED IN THE | | | MIDDLE OF THE SHEET AT THE BOTTOM. | | | PLEASE CORRELATE SHEET TITLE WITH | | | INFORMATION SHOWN ON SHEET. SECTION | | | 106.1.1. | | | 75. SHT P2-06 OVERFLOW SCUPPERS DO NOT | | | REFLECT THE OVERFLOW SCUPPERS ON THE | | | ARCHITECTURAL ON SHT A1-17. PLEASE | | | CORRELATE THE SCUPPER AMOUNT AND | | | LOCATIONS FOR THE ARCHITECTURAL AND | | | PLUMBING SHEETS. ENGINEER SHALL INDICATE | | | REQUIRED NUMBER OF SCUPPERS PER THE | | | CALCULATIONS REQUIRED FOR SECONDARY ROOF | | | DRAINS OR SCUPPERS ACCORDING TO SECTIONS | | | 1101.7, 1107.3 AND TABLE 1106.7. | | | 76. SHT P2-06 THE VENTS THRU THE ROOF DO | | | NOT REFLECT THE VENTS SHOWN ON SHT P2-05 | | | FOR LOCATION. PLEASE CORRELATE VENTS | | | FROM FLOOR TO FLOOR. SECTION 106.1.1. | | | 77. SHT P3-00 PLUMBING KEYED NOTES: | | | NUMBER 9 REFERENCES SHT P0-04. THIS | | | SHEET HAS NOT BEEN SUMBITTED. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | 78. SHT P3-00 DETAIL #4 REFERENCES UNIT | | | B2B. THIS IS NOT SHOWN IN THE SHEET | | | TITLE. PLEASE CORRELATE SHEET TITLE WITH | | | INFORMATION ON DETAILS. SECTION 106.1.1. | | | 79. SHT P3-01 PLUMBING KEYED NOTES: | | | NUMBER 9 REFERENCES SHT P0-04. THIS | | | SHEET HAS NOT BEEN SUBMITTED. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | 80. SHT P3-01 DETAIL #4 PLEASE INDICATE | | | THE KEYED NOTES NUMBERS FOR WATER DROPS | | | AT THE TUB/SHOWER, LAV/WATER CLOSET | | | PIPING. SECTION 106.1.1. | | | 81. SHT P3-02 PLUMBING KEYED NOTES: | | | NUMBER 9 REFERENCES SHT P0-04. THIS | | | SHEET HAS NOT BEEN SUBMITTED. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | 82. SHT P3-02 DETAIL #1 NO WATER RISER, | | | (#8), IS SHOWN. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | 83. SHT P3-02 DETAIL #2 HOT & COLD DROPS | | | TO THE SHOWER HAVE BEEN MISLABLED. | | | SECTION 106.1.1. | | | 84. SHT P3-03 PLUMBING KEYED NOTES: | | | NUMBER 9 REFERENCES SHT P0-04. THIS | | | SHEET HAS NOT BEEN SUBMITTED. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | 85. SHT P3-03 DETAIL #2 BOTH THE DROPS | | | TO THE WATER HEATER AND TO THE TUB HAVE | | | BEEN MISLABELED. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | 86. SHT P4-00 ALL SV RISERS DO NOT | | | REFLECT THE FLOOR PLANS FOR THE FIRST | | | FLOOR PIPING. SECTION 106.1.1. | | | 87. SHT P4-00 ALL SV RISERS DO NOT | | | REFLECT THE FLOOR PLANS FOR THE 16TH | | | FLOORS. NO VENT PIPING SHOWN FOR THE | | | REVENTS SHOWN ON THE 16TH FLOOR. SECTION | | | 106.1.1. | | | 88. SHT P4-00 SV-4 DOES NOT REFLECT THE | | | FLOOR PLANS 2ND THRU 15TH FLOORS. THIS | | | RISEER IS NOT SHOWN ON THE FIRST FLOOR. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | 89. SHT P4-00 16TH FLOOR SHALL BE | | | DIFFERENT FROM OTHE FLOOR ON ALL RISERS | | | AS THE VENTING/REVENTING IS ONLY ON THIS | | | FLOOR. SHOW ALL VENTING/REVENTING ON | | | RISERS. (THIS IS REQUIRED FOR ALL VENTS | | | INCLUDING SOVENT SYSTEM IF VENTS FROM | | | OTHER STACKS ARE TYING INTO THEM. | | | SECTION 106.1.1. | | | 90. SHT P4-00 SV-5 DOES NOT REFLECT THE | | | FLOOR PLANS FROM THE 2ND FLOOR THRU THE | | | 15TH FLOOR. OFFSET ON THE 11TH FLOOR IS | | | NOT SHOWN ON THE 11TH FLOOR FLOOR PLAN. | | | SECTION 106.1.1. | | | 91. SHT P4-00 SV-6 DOES NOT REFLECT THE | | | FLOOR PLAN ON THE 11TH FLOOR. SECTION | | | 106.1.1. | | | 92. SHT P4-00 SV-7 DOES NOT REFLECT THE | | | FLOOR PLAN ON THE 2ND FLOOR THRU THE | | | 11TH FLOOR. SECTION 106.1.1. | | | 93. SHT P4-00 SUBMIT A RISER DIAGRAM FOR | | | EACH SANTITARY RISER DIAGRAM AND EACH | | | SOVENT RISER DIAGRAM. COMMON RISERS WITH | | | DIFFERENT FLOOR PLANS ARE NOT | | | ACCEPTABLE. IF THE TUB AND LAV ARE ON | | | THE OPPOSITE SIDE OF THE WATER CLOSET | | | FROM ONE FLOOR PLAN TO THE OTHER, OR | | | OFFSETS ARE DIFFERENT, OR ON DIFFERENT | | | FLOOR PLANS, THEN SEPARATE RISER | | | DIAGRAMS ARE REQUIRED. RISER DIAGRAMS | | | SHALL REFLECT THE FLOOR PLAN FROM THEIR | | | CONNECTION TO THE BUILDING DRAIN UP THRU | | | THE ROOF FOR VENTING. BECAUSE THIS IS AN | | | ENGINEERED SYSTEM, SEPARATE RISERS ARE | | | REQUIRED, AND SEPARATE RISER | | | DESIGNATIONS ARE REQUIRED. SOME RISERS | | | CHANGE RISER NUMBERS FROM FLOOR TO FLOOR | | | PLEASE CLARIFY. FLOOR PLANS SHOW REVENTS | | | FROM OTHER RISERS TYING TOGETHER PRIOR | | | TO VENTING THRU THE ROOF. THIS IS NOT | | | REFLECTED ON ANY OF THE RISER DIAGRAMS. | | | 94. SUBMIT AN APPROVED DESIGN MANUAL FOR | | | THE SOVENT SYSTEM. SUBMIT MANUFACTURE | | | SPECIFICATIONS FOR AERATORS AND | | | DEAERATORS FOR PRODUCT APPROVAL PER | | | SECTIONS 303.1 & 303.4. | | | 95. PLANS APPEAR TO BE INCOMPLETE AT | | | THIS TIME, AS ALL THE SV RISERS ARE NOT | | | SUBMITTED AS WELL AS THE BLDG DRAIN FOR | | | OTHER SYSTEMS. OTHER COMMENTS MAY OR MAY | | | NOT FOLLOW UPON SUBMITTAL OF REQUIRED | | | INFORMATION AND INFORMATION NOT | | | SUBMITTED AT THIS TIME. SECTIONS 106.1.1 | | | AND 106.3.5.1.3. | | | 96. SHT P4-01 ALL STACKS, RELIEF VENTS | | | ARE REQUIRED PER SECTION 914.1 AND SHALL | | | BE PROVIDED AT EACH 10TH INTERVAL | | | BEGINNING WITH THE TOP FLOOR. SECTION | | | 914.1. | | | 97. SHT P4-01 ALL STACKS, EVERY VENT | | | STACK SHALL CONNECT TO THE BASE OF THE | | | DRAINAGE STACK. PLEASE SHOW VENT STACK | | | CONNECTION TO STACK. SECTION 903.4. | | | 98. SHT P4-01 ALL STACKS, NO 11TH FLOOR | | | FIXTURES SHOWN ON THE RISER DIAGRAMS. | | | CLARIFY. SECTION 106.1.1 | | | 99. SHT P4-01 ALL STACKS, DRAINAGE STACK | | | CAN NOT TERMINATE ABOVE THE 10TH FLOOR | | | AND THEN START UP AGAIN BELOW THE 12TH | | | FLOOR AS SHOWN ON THE RISER DIAGRAM. | | | SECTION 106.1.1. | | | 100. SHT P4-02 RISERS W1, W2, W6, W8, & | | | W10 FULL OPEN VALVES SHALL BE INSTALLED | | | ON THE BASE OF EVERY WATER RISER PIPE. | | | SECTION 606.1(3). | | | 101. SHT P4-04 SUBMIT THE BUILDING STORM | | | DRAIN IN AN ISOMETRIC RISER DIAGRAM THAT | | | REFLECTS THE PIPING SHOWN ON THE | | | UNDERGROUND PLUMBING PLAN SHT P2-00. | | | SECTION 106.3.5.1.3. SHOW ALL PIPE SIZES | | | AND SQUARE FOOTAGE AS IT ACCUMULATES IN | | | THE SYSTEM. IDENTIFY ALL RISERS AS THEY | | | CONNECT TO THE BUILDING DRAIN IN THE | | | ISOMETRIC DIAGRAM OF THE BUILDING DRAIN. | | | SHOW ALL OFFSETS IN THE STORM RISERS, | | | AND INDICATE ALL PIPE SIZES. | | | 102. SHTS P4-05 & P4-06 INDICATE | | | MATERIAL FOR CONDENSATE SYSTEM. NO | | | FLAMABLE MATERIAL IN THE AIR CONDITION | | | ROOM IF IT IS USED AS A PLENUM. INDICATE | | | METHOD OF VENTING THE CONDENSATE RISERS. | | | VENTS CAN NOT TERMINATE IN THE WALLS OR | | | IN A PLENUM. | | | 103. SHTS P4-05 & P4-06 SUBMIT A | | | BUILDING DRAIN CONDENSATE ISOMETRIC | | | RISER DIAGRAM THAT REFLECTS THE | | | UNDERGROUND PIPING ON SHT P2-00. SECTION | | | 106.3.5.1.3. | | | 104. SHT P5-00 DETAIL 05 WASHER BOX | | | CONNECTION WATER HAMMER ARRESTORS ARE | | | REQUIRED AT THE WASHER BOX PER 604.9. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES IN AN "EFFECTIVE | | | RANGE" NOT IN THE CEILING. PKI-WH 201 | | | AND MANUF. INSTALLATION INSTRUCTIONS. | | | 105. SHT P5-00 DETAIL 04 WATER HEATER | | | CONNECTION DETAIL: A FULL OPEN VALVE IS | | | REQUIRED ON THE SUPPLY PIPE TO EVERY | | | WATER HEATER. SECTION 606.1(7). | | | 106. SHT P5-00 DETAIL 04 WATER HEATER: | | | SUBMIT P&T RELIEF VALVE DISCHARGE PIPING | | | RISER DIAGRAM SHOWING ALL PIPE SIZES, | | | AND TERMINATION POINT. SECTION | | | 106.3.5.1.3. THE RELIEF VALVE DISCHARGE | | | SHALL NOT HAVE ANY TRAPPED SECTIONS AND | | | SHALL HAVEA VISIBLE AIR GAP OR AIR GAP | | | FITTING LOCATED IN THE SAME ROOM AS THE | | | WATER HEATER. INDICATE MATERIAL FOR P/T | | | DISCHARGE PIPING. | | | 107. SHT P5-00 DETAIL 04 WATER HEATER | | | SUBMIT EMERGENCY PAN DRAIN ISOMETRIC | | | RISER DIAGRAM SHOWING ALL PIPE SIZES, | | | MATERIAL, AND TERMINATION POINT. SECTION | | | 106.3.5.1.3. | | | 108. SHT P5-00 DETAIL 04 WATER HEATER: | | | THERMAL EXPANSION CONTROL IS REQUIRED | | | PER SECTION 607.13.2. PLEASE INDICATE | | | METHOD FOR COMPLIANCE. | | | 109. SHT P5-00 DETAIL 07 DOMESTIC WATER | | | BOOSTER PUMP DETAIL: SUBMIT MANUF. | | | SPECIFICATION SHEETS FOR PUMP. PUMP | | | SHALL BE LISTED. SECTION 303.4. | | | 110. SHT P6-00 SHOWS TWO RISER NUMBER 1 | | | AND TWO RISER NUMBER 11, AND NO RISERS | | | NUMBER 9 & 12. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | 111. SHT P6-01 NO RISER NUMBER 2. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | 112. SHT P6-03 RISER NUMBER 20 | | | MISLABELED AS RISER 19. PLEASE CORRELATE | | | RISERS. SECTION 106.1.1. | | | 113. ALL SETS OF PLANS AND ALL SHEETS IN | | | EACH SET OF PLANS: IF THE DESIGN | | | PROFESSIONAL IS AN ENGINEER, THEN HE OR | | | SHE SHALL AFFIX HIS OR HER OFFICIAL | | | SEAL, SIGNATURE AND DATE TO SAID | | | DRAWINGS AS REQUIRED BY FLORIDA | | | STATUTES. NO INITIALS. LEAGAL | | | SIGNATURE REQUIRED. | | | 114. SUBMIT WATER ISOMETRIC RISER | | | DIAGRAMS FOR EACH UNIT SHOWING ALL PIPE | | | SIZES, VALVES, AND WATER HAMMER | | | ARRESTORS REQUIRED BY SECTION 604.9. | | | SECTION 106.3.5.1.3. | | | 115. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS APPLICATION: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGHTS PER FBC-2004 | | | FUEL GAS. | | | B. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | C. TYPE OF GAS, (LP OR NATURAL) | | | D. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). | | | E. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | F. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. | | | G. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. IF | | | 2 PSI INDICATE LOCATION OF REGULATORS | | | AND SUBMIT MANUF. SPECIFICATION SHEETS | | | FOR REGULATORS INDICATING MODEL. IF | | | VENTED REGULATORS, INDICATE MATERIAL FOR | | | VENTS AND SHOW ROUTING OF PIPING. | | | H. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. | | | I. SUBMIT MANUFACTURE SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. | | | J. CLEARLY SHOW THE LOCATION AND CAP- | | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | K. CLEARLY INDICATE ON THE PLAN IF THE | | | LP TANK IS ABOVE OR BELOW GROUND, AND | | | SHOW REQUIRED PROTECTION OF THE TANK AND | | | APPURTENANCES PER NFPA 58. IF THE TANK | | | IS BELOW GROUND THE CONTAINER SHALL BE | | | SECURILY ANCHORED PER NFPA 58 SECTION | | | 3-2.2.7(H). | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | PLEASE RESUBMIT RED LINED SET OF | | | PLUMBING PLANS FROM FIRST REVIEW TO HELP | | | TO EXPEDITE THE SECOND REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2006-09-05 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2006-09-05 |
Time |
09:57 |
Sent To |
|
|
| Notes |
| 2006-09-05 00:00:00 | NORTH ELEVATION DOES NOT REFLECT DOORS | | | FOR SCOTER STORAGE ROOM. PLEASE UPDATE | | | DRAWINGS. | | | FIRST FLOOR UNITS SHALL BE RAISED 18 | | | INCHES ABOVE THE SIDEWALK LEVEL. PLEASE | | | PROVIDE INFORMATION TO CONFIRM | | | COMPLIANCE WITH REGULATION. | | | TRAVEL LANES WITH PARKING STALLS SHALL | | | BE MINIMUM 24 FEET WIDE. THE TRAVEL LANE | | | ON THE NORTH SIDE OF GARAGE IS LESS THAN | | | 24 FEET. | | | ON APPROVED PHASE I, STAIR FOR | | | MECHANICAL SPACE ALONG AUSTRALIAN AVENUE | | | IS SHOWN ENCROACHING THE SPECIAL | | | LANDSCAPE TREATMENT AREA. PLEASE ADJUST | | | OR PROCEED FOR DAC VARIANCE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-04-19 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2006-04-19 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2006-04-19 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2006-04-19 00:00:00 | 1. PLEASE PROVIDE A FULL SITE PLAN, | | | INCLUDING PHASE I, WHICH INDICATES | | | SIDEWALKS DIMENSIONS, LOCATION OF TREES, | | | AND SITE LEVELS. | | | 2. SIDEWALKS SHALL BE MINIMUM 8 FEET IN | | | WIDTH. | | | 3. 1ST FLOOR RESIDENTIAL USES SHALL BE | | | RAISED 18 INCHES FROM THE SIDEWALK | | | LEVEL. | | | 4. MAIN ENTRANCE ACCESS SHALL PROVIDE | | | FOR 8 FEET SIDEWALK IN FRONT OF DOOR AND | | | CONNECTED WITH SIDEWALK FROM STREET. | | | 5. PLEASE PROVIDE A TABLE INDICATING THE | | | PARKING SPACES PROVIDED FOR THE WHOLE | | | PROJECT. | | | 6. PLEASE PROVIDE FLOOR PLANS FOR ALL | | | LEVELS WHICH INCLUDE PARKING. THESE | | | FLOOR PLANS SHALL INCLUDE THE PHASE I, | | | ALREADY APPROVED. |
|
|
|