Plan Review Details - Permit 05110190
Plan Review Stops For Permit 05110190
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-01-13 Cont ID  
Sent By amorse Date 2006-01-13 Time 10:58 Rev Time 0.33
Received By amorse Date 2006-01-13 Time 10:58 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-13 Cont ID  
Sent By amorse Date 2005-12-13 Time 11:11 Rev Time 0.50
Received By amorse Date 2005-12-13 Time 11:11 Sent To PC
Notes
2005-12-13 00:00:00 
  
 DENIED
  
 1) DRAWING TO BE REVISED TO MEET ZONNING
 REQUIREMENT OF MAXIMUM WALL HEIGHT
  
 2) DRAWINGS TO REFLECT CURRENT 2004 FBC
 EFFECTIVE OCT.1,2005 EVEN THOUGH THE
 REQUIREMENTS MAY BE THE SAME
  
 3) A NOTICE OF COMMENCEMENT WILL BE
 REQUIRED PRIOR TO A PERMIT BEING ISSUED
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 (561)805-6716

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-09 Cont ID  
Sent By adarroug Date 2006-01-09 Time 10:54 Rev Time 0.00
Received By adarroug Date 2006-01-09 Time 10:54 Sent To B
Notes
2006-01-09 00:00:00TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-19 Cont ID  
Sent By adarroug Date 2005-12-19 Time 10:01 Rev Time 0.00
Received By adarroug Date 2005-12-19 Time 10:01 Sent To B
Notes
2005-12-19 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-11-21 Cont ID  
Sent By adarroug Date 2005-11-21 Time 11:39 Rev Time 0.00
Received By adarroug Date 2005-11-21 Time 11:39 Sent To B
Notes
2005-11-21 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-11-14 Cont ID  
Sent By adarroug Date 2005-11-14 Time 18:51 Rev Time 0.00
Received By adarroug Date 2005-11-14 Time 18:51 Sent To Z
Notes
2005-11-14 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-07 Cont ID  
Sent By mmclean Date 2006-01-07 Time 10:10 Rev Time 0.00
Received By mmclean Date 2006-01-07 Time 10:10 Sent To I
Notes
2006-01-07 00:00:00PROVISO: WALL CAN ONLY BE BUILT AT A
 MAXIMUM HEIGHT OF 6FT ONLY.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-11-18 Cont ID  
Sent By mmclean Date 2005-11-18 Time 15:29 Rev Time 0.00
Received By mmclean Date 2005-11-18 Time 15:29 Sent To I
Notes
2005-11-18 00:00:00DENIED,
 1. THE PROPOSED CMW IS OVER THE HEIGHT
 REQUIREMENT OF 6FT. (MUST REDUCE THE
 HEIGHT OF CMW ON THE PLANS AND CHANGE
 THE DESCRIPTION).
  
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720


Account Summary | Usage Policy | Privacy Policy