Plan Review Details - Permit 05110189
| Plan Review Stops For Permit 05110189 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-21 |
Time |
07:25 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-16 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2007-08-17 06:04:20 | | | | | | | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 05110189 | | | ADD: 2025 N. DIXIE HWY | | | CONT: GR CONCEPTS | | | TEL: (561)743-0066 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 3RD | | | ACTION: DENIED | | | | | | --- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | AT THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OF THE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | ------------------------------------- | | | ) NUMBER OF FLOORS | | | ) SPACE/ FL | | | ) SQ. FT. FOOTPRINT | | | ) SQ. FT. UNDER ROOF (TOTAL) | | | ) OCCUPANT LOAD | | | ) FLOOD ZONE | | | ) FLOOD ELEVATION | | | )L.O.M.R. | | | | | | 5) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE | | | REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE.SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG. NOTE: THE | | | PRODUCT APPROVALS FOR THE DOORS AND WINDOWS ARE | | | EXPIRED. SUBMIT NEW AND | | | UP-DATED PRODUCT APPROVALS FOR THE | | | DOORS/WINDOWS/SHUTTERS/ROOFING MATERIALS | | | ETC. | | | NEW*** TWO SETS OF PRODUCT APPROVALS SHALL BE SUBMITTED | | | FOR EACH PRODUCT.THE PRODUCT APPROVAL FOR THE | | | ROOFING. | | | FBC 1609.6.2.2 THE SYSTEM SELECTED | | | FROM THE SUBMITTED FLAT ROOF PRODUCT | | | APPROVAL NOA HAS A MAXIMUM DESIGN | | | PRESSURE OF LESS THAN -89 PSF AND CITES | | | GENERAL LIMITATION #9 (SEE PAGE 12_ OF | | | _41_).GENERAL LIMITATION #9 PROHIBITS | | | RATIONAL ANALYSIS OR EXTRAPOLATION TO | | | ENHANCE THE UPLIFT PRESSURE AT PERIMETER | | | AND CORNER AREAS BY REDUCING THE | | | FASTENER SPACING IN THESE AREAS.EITHER | | | SELECT AN ALTERNATIVE SYSTEM (OR PRODUCT | | | APPROVAL) THAT DOES NOT CITE GENERAL | | | LIMITATION #9.ALTERNATIVELY IF THE | | | SELECTED SYSTEM DOES CITE GENERAL | | | LIMITATION #9, IT MUST HAVE A MAXIMUM | | | DESIGN PRESSURE THAT EXCEEDS THE | | | PRESSURE IN ROOF ZONE 3 (TYPICALLY -89 | | | PSF FOR MEAN ROOF HEIGHT OF 30 FEET OR | | | LESS). | | | | | | 6) OK | | | | | | 7) 13-103.1.2 THE BUILDING OWNER, THE OWNER'S | | | ARCHITECT, OR OTHER AUTHORIZED AGENT LEGALLY DESIGNATED | | | BY THE OWNER SHALL CERTIFY THAT THE BUILDING IS IN | | | COMPLIANCE WITH THE CODE, AS PER SECTION 553.907, | | | FLORIDA STATUTES, PRIOR TO RECEIVING THE PERMIT TO | | | BEGIN CONSTRUCTION OR RENOVATION. | | | IF, DURING THE BUILDING'S CONSTRUCTION OR RENOVATION, | | | ALTERATIONS ARE MADE IN THE BUILDING?S DESIGN OR IN | | | MATERIALS OR EQUIPMENT INSTALLED IN THE BUILDING WHICH | | | WOULD DIMINISH ITS ENERGY PERFORMANCE, AN AMENDED COPY | | | OF THE COMPLIANCE CERTIFICATION SHALL BE SUBMITTED TO | | | THE BUILDING OFFICIAL ON OR BEFORE THE DATE OF FINAL | | | INSPECTION BY THE BUILDING OWNER OR HIS OR HER LEGALLY | | | AUTHORIZED AGENT. | | | BEFORE A BUILDING PERMIT CAN BE ISSUED, THE SUBMITTED | | | ENERGY CODE COMPLIANCE FORMS SHALL BE SIGNED BY THE | | | BUILDING OWNER, THE | | | OWNER?S ARCHITECT OR OTHER AUTHORIZED AGENT LEGALLY | | | DESIGNATED BY THE OWNER. | | | | | | 8) OK | | | | | | 9) OK | | | | | | 10) OK | | | | | | NO RESPONSE**** | | | 11) EXPLAIN WHAT TYPE OF WORK IS CARRIED OUT IN THE | | | WORKSHOP AREA. WHAT TYPE OF MATERIAL WILL BE DISPLAYED | | | IN THE SHOW ROOMS? THE BUILDING OCCUPANCY MAY CHANGE | | | DUE TO THE USE OF THE WORKSHOP AND OTHER AREAS IN THE | | | BUILDING. | | | | | | 12) OK | | | | | | 13) OK | | | | | | 14) OK | | | | | | NEW************ | | | | | | A)SHEET 3.1 THE DIMENTIONS FOR F-I ON THE FOUNDATION | | | LEGEND DO NOT MATCH DETAIL #3 ON SHEET 8.2. CLARIFY. | | | | | | B)GEOTECHNICAL TESTING LAB RECOMEND THAT THE MINIMUM | | | CONTINOUS FOOTING WIDTH BE 30". THE CONTINOUS FOOTING | | | ON SHEET 3.1 SHOWS A 20" WIDTH. THE TESTING LAB REPORTS | | | SHALL NOT BE IGNORED. | | | | | | C)A FRAMING HEADDER DETAIL FOR THE NEW 3 FOOT OPENING | | | CONNECTING THE BUILDINGS IS REQUIRED. SEE SHEET 4.1 | | | | | | D)HOW CAN THE FOUNDATION /FLOOR AND ROOF PLAN HAVE | | | THE SAME DETAIL? #3 SHEETS 8.1. SEE PAGES 3.1 / 4.1 AND | | | 6.1. FBC 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOACTION, NATURE AND | | | EXTENT OF THE WORK PROPOSED. | | | | | | E)FBC TABLE 1607.1 IF THE MEZZANINE IS USED AS OFFICE | | | SPACE THE DESIGN FLOOR LOAD SHALL BE 50 PSF. INDICATE | | | THE STAIRS FLOOR LOAD ON THE PLANS. | | | | | | F)FBC 903.2.6 IF THE BUILDING IS DECLEARED AS GROUP M | | | THERE IS A POSSIBILITY IT WILL REQUIRE A SPRINKLER | | | SYSTEM ACCORDING TO THIS SECTION. | | | | | | G)FBC. 302.3WHEN A BUILDING IS OCCUPIED BY TWO OR | | | MORE USES NOT INCLUDED IN THE SAME OCCUPANCY | | | CLASSIFICATION, THE BUILDING OR PORTION THEREOF SHALL | | | COMPLY WITH SECTION 302.3.1 OR 302.3.2. | | | | | | H)FBC. 1607.7.1 HANDRAIL ASSEMBLIES AND GURADS SHALL | | | BE DESIGNED TO RESIST A LOAD OF 50 PLF APPLIED IN ANY | | | DIRECTION AT THE TOP AND TO TRANSFER THIS LOAD THROUGH | | | THE STRUCTURE. | | | | | | I)FBC. 1607.7.1.1 THE GUARD RAIL SHALLBE ABLE TO | | | RESIST A SINGLE CONCENTRATED LOAD OF 200 POUNDS. SHOW | | | IN DETAIL HOW THESE REQUIREMENTS WILL BE MET. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-07-06 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2006-07-06 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2006-07-05 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05110189 | | | ADD: 2025 N. DIXIE HWY | | | CONT: GR CONCEPTS | | | TEL: (561)743-0066 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | 1) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS | | | NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION | | | THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | ------------------------------------- | | | ) NUMBER OF FLOORS | | | ) SPACE/ FL | | | ) SQ. FT. FOOTPRINT | | | ) SQ. FT. UNDER ROOF (TOTAL) | | | ) OCCUPANT LOAD | | | ) FLOOD ZONE | | | ) FLOOD ELEVATION | | | )L.O.M.R. | | | | | | 5) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE | | | REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY | | | NUMBER FROM THE STATE.SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG. NOTE: THE | | | PRODUCT APPROVALS FOR THE DOORS AND | | | WINDOWS ARE EXPIRED. SUBMIT NEW AND | | | UP-DATED PRODUCT APPROVALS FOR THE | | | DOORS/WINDOWS/SHUTTERS/ROOFING MATERIALS | | | ETC. | | | | | | 6) OK | | | | | | 7) 13-103.1.2 CODE COMPLIANCE | | | CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S | | | ARCHITECT, OR OTHER AUTHORIZED AGENT | | | LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY THAT THE BUILDING IS IN | | | COMPLIANCE WITH THE CODE, AS PER SECTION | | | 553.907, FLORIDA STATUTES , PRIOR TO | | | RECEIVING THE PERMIT TO BEGIN | | | CONSTRUCTION OR RENOVATION. | | | IF, DURING THE BUILDING?S CONSTRUCTION | | | OR RENOVATION, ALTERATIONS ARE MADE IN | | | THE BUILDING?S DESIGN OR IN MATERIALS OR | | | EQUIPMENT INSTALLED IN THE BUILDING | | | WHICH WOULD DIMINISH ITS ENERGY | | | PERFORMANCE, AN AMENDED COPY OF THE | | | COMPLIANCE CERTIFICATION SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL ON OR | | | BEFORE THE DATE OF FINAL INSPECTION BY | | | THE BUILDING OWNER OR HIS OR HER LEGALLY AUTHORIZED | | | AGENT. | | | | | | 8) OK | | | | | | 9) SHEET 3.1 REFERS TO DETAIL #3 ON PAGE | | | 8.1, HOWEVER, THERE IS NO DETAIL #3 ON | | | SHEET 8.1. THERE IS ALSO A REFERENCE TO | | | DETAIL #1 ON SHEET 8.2 BUT THERE IS NO | | | #1 DETAIL ON SHEET 8.2. ALL THESE | | | REFERENCES NEEDS TO CORRESPOND WITH THE | | | REFERENCE PAGES INDICATED. AN ARROW | | | POINTING IN THE DIRECTION OF THE CROSS | | | SECTION WILL INDICATE CLEARLY WHICH | | | ELEVATION WILL BE SHOWN. CHECK ALL PAGES | | | FOR CORRECT REFERENES. SEE SHEET 4.1/7.1 | | | ETC. FOR SIMULAR ERRORS. | | | | | | 10) THE DESCRIPTION ON THE APPLICATION | | | INDICATE ADDITION TO EXISTING BUILDING | | | ONLY. HOWEVER THE PLANS SHOWS MAJOR | | | REMODELING OF THE EXISTING BUILDING. THE APPLICATION | | | STATES :DESCRIBE PROJECT IN | | | DETAIL: ADJUST THE APPLICATION ACCORDINGLY. | | | | | | 11) INDICATE THE USE OF THE MEZZANINE | | | AREA AND THE WORKSHOP AREAS. THE | | | OCCUPANT LOAD IS ALSO REQUIRED FOR THESE | | | AREAS. | | | | | | 12) THE NEW H/C TOILETS SHALL MEET THE REQUIREMENTS OF | | | 11-4.16/11-4.19/11-4.24ETC ALSO SEE | | | FIG.30E CH.11. | | | | | | 13) SHEET 4.1 REFERENCE CERTAIN DETAILS | | | AND PAGES WHICH CANNOT BE LOCATED ON THE | | | DRAWINGS. MODIFY THE DRAWINGS | | | ACCORDINGLY. | | | | | | 14) ONCE AGAIN PROVIDE THE ELEVATIONS OF | | | THE FLOORS SHOWING THE CEILING HEIGHTS. | | | MEZZANINES ARE REQUIRED TO HAVE CEILING | | | HEIGHT OF NOT LESS THA 7' AND THE | | | CEILING HEIGHT BELOW THE MEZZANINE MUST | | | ALSO BE 7'.FBC.505.1 | | | | | | NOTE: WHEN RESUBMITTING PLANS, INDICATE | | | THE REVISION AND REMOVE AND REPLACE THE | | | OLD SHEETS. SUBMIT TWO COMPLETE NEW SETS | | | OF DRAWINGS AND ONE OLD SET FOR REVIEW. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | (561)805-6726 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2006-03-01 |
Time |
17:19 |
Rev Time |
12.00 |
| Received By |
mjacobs |
Date |
2006-03-01 |
Time |
07:12 |
Sent To |
PC |
|
| Notes |
| 2006-02-28 00:00:00 | | | | 1)ALL PLANS SUBMITTED AFTER OCTOBER, 1, | | | 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 2)THOSE PRODUCT APPROVALS WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. THE CITY | | | WPB AMMENDMENT TO FBC 106.3.3. EACH | | | PRODUCT APPROVAL NEEDS ITS OWN STATE | | | COVER SHEET WITH THE FL#. | | | | | | 3) THE SCALE ON PAGE 1.1 SHOWS 1"=1' | | | HOWEVER WHEN SCAILING THE DRAWINGS, THIS | | | SCALE WON'T WORK. PLEASE CLARIFY. | | | | | | 4) ON PAGE 3.1 INDICATE THE SLOPE OF THE | | | NEW RAMP.SEE F.B.C. 11-4.8. ALSO, IN | | | REFERENCE TO THE DETAILS OF SHEET 8.3, | | | WHERE IS SHEET 8.3? | | | | | | 5) THE ADDRESS ON THE PAGES NEED TO | | | MATCH NEED TO MATCH. SOME INDICATE 2025 | | | N.DIXIE HIGHWAY AS THE ADDRESS AND | | | OTHERS HAVE 2025 S.DIXIE HIGHWAY. MAKE | | | SURE ALL SHEETS SHOW THE SAME ADDRESS. | | | | | | 6) (2004 FBC) 106.1.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE & | | | EXTENT OF THE WORK PROPOSED & SHOW IN | | | DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND REVELENT | | | LAWS, ORDINANCES, AND RULES AND | | | REGULATIONS AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | | | | 7) 109.3.10* IMPACT OF CONSTRUCTION. ALL | | | CONSTRUCTION ACTIVITY REGULATED BY THIS | | | CODE SHALL BE PERMORMED IN A MANNER SO | | | AS NOT TO ADVERSLY IMPACT THE CONDITION | | | OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID | | | PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS | | | &CONDITIONS AGREEABLE TO THE APPLICABLE | | | PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | | LIMITED TO THE CONTROL OF DUST, NOISE, | | | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. | | | NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT HISTORIC SURFACE WATER | | | DRAINAGE FLOWS SERVING ADJACENT | | | PROPERTIES, & MAY REQUIRE SPECIAL | | | DRAINAGE DESIGNCOMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED | | | SITES.ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENET, INCLUDING | | | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, | | | DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN | | | EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALY | | | PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9)11-4.6.2 LOCATION. | | | ACCESSIBLE PARKING SPACES SERVING A | | | PARTICULAR BUILDING SHALL BE LOCATED ON | | | THE SHORTEST SAFELY ACCESSIBLE ROUTE OF | | | TRAVEL FROM ADJACENT PARKING TO AN | | | ACCESSIBLE ENTRANCE. IN PARKING | | | FACILITIES THAT DO NOT SERVE A | | | PARTICULAR BUILDING, ACCESSIBLE PARKING | | | SHALL BE LOCATED ON THE SHORTEST | | | ACCESSIBLE ROUTE OF TRAVEL TO AN | | | ACCESSIBLE PEDESTRIAN ENTRANCE OF THE | | | PARKING FACILITY. IN BUILDINGS WITH | | | MULTIPLE ACCESSIBLE ENTRANCES WITH | | | ADJACENT PARKING , ACCESSIBLE PARKING | | | SPACES SHALL BE DISPERSED AND LOCATED | | | CLOSEST TO THE ACCESSIBLE ENTRANCES. | | | EACH PARKING SPACE MUST BE NO LESS THAN | | | 12 FEET (3658 MM) WIDE. | | | (1)ALL SPACES MUST BE LOCATED ON AN | | | ACCESSIBLE ROUTE NO LESS THAN 44 INCHES | | | (1118 MM)WIDE SO THAT USERS WILL NOT BE | | | COMPELLED TO WALK OR WHEEL BEHIND PARKED | | | VEHICLES. SEE ADDITIONAL INFORMATION IN | | | PACKAGE. | | | | | | 10) SHEET 4.1. STATE THE MEAN ROOF | | | HEIGHT ON THE DRAWINGS. ALSO WHAT IS THE | | | LIVE AND DEAD LOAD FOR THE MEZZANINE | | | AREA? WHAT WILL THE MEZZANINE BE USE FOR | | | STORAGE OR WILL THERE BE WORK TAKING | | | PLACE ON THE MEZZANINE. | | | SEE FBC 11-4.1.3 (1-5) FOR | | | ACCESSIBILITY. | | | | | | 11) EXPLAIN WHAT TYPE OF WORK IS CARRIED | | | OUT IN THE WORKSHOP AREA. WHAT WILL BE | | | DISPLAYED IN THE SHOW ROOMS? | | | | | | 12) ADDITIONAL INFORMATION IS REQUIRED | | | FOR THE BRACING AROUND THE HOLES FOR THE | | | A/C UNITS. A DETAIL DRAWING IS REQUIRED | | | SHOWING ALL BRACING. | | | | | | 13) SHEET 4.1 REFERENCE CERTAIN DETAIL | | | AND PAGES WHICH CANNOT BE LOCATED ON THE | | | DRAWINGS. MODIFY DRAWINGS ACCORDINGLY TO | | | SHOW CORRECT DETAILS. | | | | | | 14) PROVIDE AN FRONT ELEVATION OF THE | | | MEZZANINE SHOWING THE FIRST FLOOR HEIGHT | | | AND THEMEZZANINE. ALSO SHOW THE | | | GUARDRAIL. A DETAIL DRAWING OF THE | | | GUARDRAIL IS ALSO REQUIRED. WHAT IS THE | | | HEIGHT OF THE WALL? IS IT 42" OR 4'? | | | WILL THERE BE AHY OPENING IN THIS WALL? | | | IF SO SHOW ON ELEVATION DRAWINGS. | | | | | | 15) 713.13 F.S.A NOTICE OF | | | COMMENCEMENT SHALL BE RECORDED AT PALM | | | BEACH COUNTY COURTHOUSE AND A COPY | | | SUBMITTED TO THIS OFFICE BEFORE A PERMIT | | | CAN BE ISSUED. BLANK FORMS ARE AVAILABLE | | | FROM THIS OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | TEL:(561)805-6726 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-12 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-12 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2007-08-12 15:05:57 | ** DENIED 3RD REVIEW ** | | | | | | ** PLEASE SEE NOTES FROM PREVIOUS REVIEWS WHICH STILL | | | NEED TO BE ADDRESSED. | | | | | | | | | 1) NOTE: PLEASE SEE COMPLIANCE WITH FBC CHAPTER 13 HAS | | | STILL NOT BEEN ACHIEVED. | | | PLEASE SEE MISSING TIME SCHEDULING. | | | PLEASE SEE NO OVER RIDE DEVICES AS REQUIRED PER CODE. | | | PLEASE SEE MISSING MAXIMUM OVER RIDE TIMES. | | | PLEASE SEE MISSING CONTROLS/SYSTEM FOR EACH LEVEL AS | | | ONE SYSTEM MAY NOT FEED MULTIPLE LEVELS. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED ARE NOW | | | UNDER THE NEW CODE WHICH WAS ADOPTED DECEMBER 8TH, | | | 2006. THIS PROJECT WAS APPLIED FOR IN NOVEMBER OF 05 | | | WHICH PLACES THE ENERGY CALCULATIONS UNDER A DIFFERENT | | | VERSION. *MAY NOT USE CALCULATIONS FROM ONE ADOPTED | | | CODE AND PLANS DESIGNED UNDER ANOTHER* | | | PLEASE CLARIFY HOW NO EXTERIOR LIGHTING IS ENTERED INTO | | | THE ENERGY CALCULATIONS WHEN THE PLANS CLEARLY SHOWS | | | LIGHTING?13-415.2.ABC.1.3 | | | THIS HAS BEEN CONFIRMED WITH THE STATE OF FLORIDA | | | BUILDING COMMISSION. | | | PLEASE SEE THE ENERGY CALCULATIONS SUBMITTED DOES NOT | | | CORRELATE WITH PLANS FOR THE METHOD OF CONTROLS, | | | FIXTURES, WATTAGE ETC. | | | PLEASE SEE THE CALCULATIONS ARE REQUIRED TO BE SIGNED, | | | DATED AND SEALED PER 13-103.1.1.1 | | | FS 481.221/471.025 | | | | | | PLEASE SEE 13-415.2.ABC.1, 13-415.1.A, | | | 13-415.2.ABC.1.1, 13-415.2.ABC.1FOR PERFORMANCE | | | CALCULATIONS/ENERGY CALCULATIONS TO BE SHOWN FOR | | | COMPLIANCE WHICH IS NOT DONE AT THIS TIME. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2, .1.3FOR LIGHTING | | | CONTROLS, FIXTURES, SCHEDULING , OVER-RIDES, MORE THAN | | | ONE FLR, LOCATIONS OF OVER-RIDE DEVICES AND TIME | | | LIMITS. | | | | | | 2) NOTE: PLEASE SUBMIT A FIXTURE LEGEND WHICH | | | CORRELATES WITH THE CALCULATIONS FOR CHAPTER 13 AS | | | SUBMITTED. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 3) NOTE: PLEASE SEE THE TWO PREVIOUS REVIEWS REQUESTED | | | PHOTO-METRICS FOR STAIRS FOR EGRESS HOWEVER THESE ARE | | | STILL NOT SUBMITTED. | | | PLEASE SEE FLORIDA ADMINISTRATIVE CODE 61G15-33.004 AS | | | THIS IS REQUIRED AS A PART OF MINIMUM LIGHTING DESIGNS | | | FOR ENGINEER. | | | NFPA-101 2003 7.8.1.3,7.9.2.2 | | | ** PLEASE SHOW AND INDICATE ALL OTHER EM/EXT LTS NEW OR | | | EXISTING ON PLANS . | | | | | | 4) NOTE:THIS IS THE SAME NOTE AS PREVIOUS REVIEW. | | | PLEASE SEE LOADS SHOWN ON PANEL "D" DO NOT SEEM TO | | | CORRELATE WITH THE LOADS INDICATED ON PANEL "E". PANEL | | | *E* IS SHOWN BEING FED FROM PANEL *D*. PLEASE | | | COORDINATE. | | | PLEASE STILL CLARIFY SERVICE AS THIS IS STILL BEING | | | SHOWN AS 120/240 ON PANELS AND RESPONSE AND NOTE | | | MENTIONS DELTA SERVICE WITH HIGH-LEG YET THE NOTE ALSO | | | MENTIONS THIS IS A 208V SERVICE. HOW IS THIS POSSIBLE? | | | PLEASE ADJUST AND CLARIFY SERVICE AS SHOWN. | | | PLEASE ADJUST LOAD CALCULATIONS AS NEEDED. | | | NEC 220, 230, 310, 408 ETC THERE ARE MANY ITEMS TO | | | REVIEW FOR COMPLIANCE, HOWEVER AS SERVICE IS NOT CLEAR | | | NOT PARTICULAR REVIEW OF THIS EQUIPMENT CAN BE DONE. | | | FBC 106.3.5.1.2 | | | | | | 5) NOTE: PLEASE SEE MISSING EQUIPMENT GROUNDING | | | CONDUCTORS FROM GUTTER TO EACH DISCONNECT A, B AND C. | | | 250.110, 250.122 ETC. | | | | | | 6) NOTE: PLEASE SUBMIT TWO COMPLETE SETS OF PLANS. | | | FBC ADMIN SECTION 106.1 | | | | | | 7) NOTE:PLEASE SEE PREVIOUS REVIEW WHICH GAVE NOTICE | | | TO FLORIDA STATUTES 553.80(2)(B) DUE TO REPEAT CODE | | | COMPLIANCE COMMENTS. | | | PLEASE SEE THIS FEE HAS NOW BEEN ASSESSED AS REQUIRED | | | BY THE FLORIDA STATUES. THIS IS A REQUIRED STATUTE. | | | THIS FEE OF $9,788.82 IS DUE BEFORE NEXT RE-SUBMITTAL | | | OF PLANS. ELECTRICAL PLANS AND CALCULATIONS SUBMITTED | | | ARE RETAINED AT THIS TIME. | | | PLEASE SEE NOTICE TO FS553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS. | | | TO DATE NO ONE HAD CONTACTED THIS OFFICE TO GO OVER | | | THESE COMMENTS. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-06-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-15 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-15 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | A | | | ********* UNSAT 2ND REVIEW ******** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIUOUS | | | REVIEW AND SOME NEW NOTES DUE TO ITEMS | | | ON PLANS NOT ON ORIGINAL. | | | | | | 1) NOTE: PLEASE SEE PREVIOUS NOTE #1 | | | MENTIONED PLANS CAME IN DESIGNED UNDER | | | THE 2001 FBC WHERE THE DESIGNS AFTER OCT | | | 1ST 2005 REQUIRED CHANGE TO THE 2004 | | | FBC. | | | PLEASE SEE ENERGY CODE COMPLIANCE FORMS | | | ARE STILL BEING SHOWN UNDER THE 2001. | | | PLEASE SEE THERE ARE NUMEROUS CHANGES | | | UNDER THE 2004 FBC CHAPTER 13 AND | | | LIGHTING DENSITIES ETC. | | | PLEASE SEE 13-415.2.ABC.1 FOR | | | PERFORMANCE CALCULATIONS TO BE SHOWN FOR COMPLIANCE | | | WHICH IS NOT DONE AT THIS | | | TIME. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2, .1.3 | | | FOR LIGHTING CONTROLS, FIXTURES, | | | SCHEDULING , OVER-RIDES, MORE THAN ONE | | | FLR, LOCATIONS OF OVER-RIDE DEVICES AND | | | TIME LIMITS. | | | PLEASE SEE MIN VOLTAGE DROP INFORMATION | | | FOR WORST CASE SHALL BE SHOWN PER | | | 13-413.1.ABC.1 | | | PLEASE SEE 13-415.1.ABC.3 ETC | | | | | | 2) NOTE: PLEASE SEE MISSING | | | PHOTO-METRICS FOR STAIRSAS NOTED ON | | | PREVIOUS REVIEW. PLEASE SEE THIS DETAIL | | | CAN BE TYPICAL FOR EACH IF APPLICABLE | | | FOR SAME TYPE OF FIXTURES ANDLAYOUT. | | | NFPA-101 2003 7.8.1.3,7.9.2.2 | | | ** PLEASE SHOW AND INDICATE ALL OTHER | | | EM/EXT LTS NEW OR EXISTING ON PLANS . | | | | | | 3) NOTE: PLEASE SEE LOADS SHOWN ON PANEL | | | "D" DO NOT SEEM TO CORRELATE WITH THE | | | LOADS INDICATED ON PANEL "E". | | | PLEASE CLARIFY. | | | PLEASE ALSO VERIFY LOAD CALCULATION AS | | | SERVICE IS BEING SHOWN AS 3-PHASE YET IT | | | SEEM ONLY THE A/C LOADS ARE BEING | | | FIGURED AT 3-PHASE. | | | PLEASE SEE NEC 220, | | | | | | 4) NOTE: PLEASE SEE ARCHITECTURAL PLANS | | | WHICH INDICATE NEW WORK IN OTHER AREAS , | | | YET THE ELECTRICAL PLANS DO NOT | | | CORRELATE WITH THIS. | | | PLEASE SEE NEW LIGHTING IS MENTIONED AND | | | AREAS TO BE REMODELED, YET NONE IS | | | SHOWN?? | | | PLEASE COMPLETE. | | | | | | 5) NOTE: PLEASE SEE NOTICE TO FS | | | 553.80(2)(B) WITH RESPECT TO REPEAT | | | COMMENTS. | | | THIS IS ONLY A NOTICE GIVEN AT THIS | | | TIME. | | | | | | ** PLEASE SEE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | | | | ** PLEASE BE SURE TO REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | ** PLEASE SUBMIT ONLY ONE COPY OF THE | | | OLD/VOIDED SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTRUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | 2006-06-14 00:00:00 | PLANS IN ELECTRICAL FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-24 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-24 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2005-12-24 00:00:00 | *********** UNSAT ********** | | | | | | ** PLEASE SEE PLANS REFERENCE THE 2001 | | | FBC, HOWEVER AS OF OCT 1ST, 2005, THE | | | CODE HAS CHANGED TO THE 2004 FBC. | | | PLEASE ADJUST DESIGNS REQUIRED. | | | THIS IS REQUIRED FOR ALL TRADES WHETHER | | | OR NOT COMMENT IS MADE BY OTHER | | | REVIEWER(S). | | | ALL PLANS ARE TO DICTATE CURRENT | | | RELEVANT CODES. | | | | | | 1)NOTE: PLEASE SEE TWO COMPLETELY | | | DIFFERENT RISER DIAGRAMS WERE SUBMITTED. | | | IT IS ASSUMED, THE RISER SHOWN ON 10.2 | | | IS THE ONE FOR REVIEW , AS THE PREVIOUS | | | RISER IS INCOMPLETE AND WOULD HAVE | | | NUMEROUS COMMENTS. | | | THIS REVIEW IS FOR THE ONE ON 10.2, | | | | | | A) PLEASE CONDUCTORS FROM GUTTER TO THE | | | RELOCATED EXISTING MAINS. | | | | | | B)NOTE: PLEASE INCLUDE THOSE EXISTING | | | DISCONNECTS SIZES. | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE "D" | | | INDICATE DEDICATED BATHROOM CIRCUIT, | | | HOWEVER ONLY TWO BATHROOMS ARE SHOWN AND | | | NEITHER OF THOSE CONTAIN ELECTRICAL GFI | | | RECEPTS??? | | | | | | 3)NOTE: PLEASE VERIFY SIGN CIRCUIT PER | | | 600.5. | | | | | | 4)NOTE: PLEASE INDICATE LOADING FOR | | | SHYOW WINDOW CIRCUIT. 220.12A | | | PLEAS ADJUST THE # OF CIRCUITS OF | | | NEEDED. | | | | | | 5)NOTE: PLEASE SEE LOADS FOR RTU'S | | | APPEAR TO BE ROUNDED DOWN? | | | PLEASE SEE EACH IS SHOWN AS 10,800VA, | | | HOWEVER THE TOTAL VA SHOWN ON LOAD CALCS | | | DOES NOT CORRELATE. | | | PLEASE ALSO SEE 43KW + IS MORE THAN | | | 104A'S. | | | 215.5 | | | | | | 6)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | | AT 125% ALONG WITH ANY LARGEST MOTOR | | | LOADS. | | | 215.3,230.42 ETC. | | | | | | 7)NOTE: PLEASE SEE NOTE ON 10.2 MENTIONS | | | TO SEE MEZZ PLANS FOR ELECTRICLA AND | | | EGRESS LTS, HOWEVER THIS COULD NOT BE | | | LOCATED ON ELECTRICAL SHEETS SUBMITTED. | | | PLEASE SEE NFPA-101 7.8,7.9. | | | PLEASE SEE A MIN OF 10FT CANDLES IS NOW | | | REQUIRED FOR EGRESS STAIRS UNDER NORMAL | | | POWER AND A MIN OF 1FT CANDLE UNDER | | | EMERGENCY POWER. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FORM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | ** PLEASE REMOVE ANY OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE SUBMIT ONE COPY OF ANY OLD/VOIDED | | | SHEETS FOR REFERENCE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THEREARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-08-23 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-08-23 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2007-08-23 13:36:37 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON DRAWINGSTHE LOCATION OF DUMPSTER & | | | ITS ENCLOSURE PER CITY OF WPB, LOCATION MUST BE | | | ACCESSIBLE FOR PICKUP TRUCK. | | | 3. PLEASE SHOW ON YOUR CALCULATIONS, HOW DID YOU | | | CALCULATE FIRST FLOOR ELEVATION, DID YOU CONSIDER | | | CENTER LINE OF ROAD , SIDEWALK ELEVATION,FLOOD ZONE | | | AREA,5,10, 25, 100 YEAR FLOOD CRITERIATO DETERMINE | | | THE FIRST FLOOR ELEVATION??PLEASE SHOWTHESE IN YOUR | | | STORM WATER CALS. | | | 4. MAKE SURE THESE SITE AREAS SHOWN ON DRAWINGS MUST | | | MATCH WITH AREAS USED IN STORM WATER QUALITY | | | CALCULATIONS. | | | 5. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM | | | WATER PIPES.PLEASE SHOW DETAIL OF THE CONTROL | | | STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, DO YOU HAVE EXFILTRATION | | | TRENCHES. PLEASE SHOW DRY DETENTION/WET DETENTION AREAS | | | IN YOURWATER QUALITY CALCULATIONS | | | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST AROUND | | | YOUR SITE EVENTHOUGH THEY ARE NOT IN YOUR SITE. | | | 7. PLEASE PROVIDE A COPY OF SFWMD PERMIT,,PLEASE | | | RESUBMIT A COPY OF GEO-TECH REPORT AND A LATESTEST COPY | | | OF STORM STORM WATER QUALITY CALCULATIONS . | | | 8. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT | | | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE | | | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & | | | PARTICLES. | | | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED | | | 10. PLEASE PROVIDE LATEST COPY OF CIVIL DRAWINGS THAT | | | WERE APPROVED AT 45TH STREET. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2006-07-28 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2006-07-28 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2006-07-28 00:00:00 | PASS 7-28-06 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2006-01-27 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2006-01-27 |
Time |
15:13 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2006-01-27 |
Time |
15:13 |
Sent To |
|
|
| Notes |
| 2006-01-27 00:00:00 | FAILED: | | | | | | 1. PLEASE PROVIDE STORM WATER | | | CALCULATION FOR THE PROPOSED IMPROVMENT | | | ON THE ENTIRE SITE. | | | 2. SHEET C1, SHOWS TWO C.S. STRUCTURE, | | | PLEASE VERIFY. | | | 3. SHEET C1 SHOWS A POWER POLE AT THE | | | PROPOSED CURB CUT, IS THIS A FPL POLE OR | | | BELONG TO THE CITY? NOTE THAT, IT SHOULD | | | BE RELOCATED BY THE DEVELOPER WITH A | | | PERMIT ISSUED FROM PUBLIC UTILITY | | | DEPARTMENT AND FPL. | | | 4. ANY WORK WITHIN PUBLIC R.O.W WOULD | | | REQUIRED A PERMIT FROM PUBLIC UTILITIES, | | | THE PROPOSED 15 IN. STORM PIPE SHOULD BE | | | RCP TYPE(IN PUBLIC R.O.W.), CONTACT | | | 494-1086, WINDEL PALMER. | | | 5. ARE THERE NEW CONNECTIONS FOR WATER | | | AND SEWER OR THE EXISTING WILL BE USED? | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-09-06 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-09-06 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-09-06 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2007-09-06 15:36:59 | ***PROVISO*** | | | | | | 1) THIS SUBMITTAL WAS PASSED DURING PREVIOUS REVIEWS. | | | PLANS WILL BE STAMPED WHEN PASSED BY OTHER REVIEWERS. | | | | | | 2) PROJECT DATA INDICATES THAT THIS PROJECT IS | | | UNSPRINKLERED. LIFE SAFETY NOTE INDICATES PROPOSED FIRE | | | SPRINKLER SYSTEM. PLEASE ADVISE AND CORRELATE SHEETS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-07-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-07-18 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-07-18 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | NEEDS, SEE ELEC COMMENTS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-12-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-12-06 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-12-06 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2005-12-06 00:00:00 | 1. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM INFORMATION SHOWN | | | ON PAGE 10.2. | | | | | | 2. ALL GUARDRAILS AND HANDRAILS ARE TO | | | MEET THE PRESCRIPTIVE STRENGTH | | | REQUIREMENTS OF THE FLORIDA BUILDING AND | | | FIRE CODE. | | | | | | 3. THE NEW ADDITION SHALL COMPLY WITH | | | THE LATEST EDITION OF THE CODE. | | | | | | 4. BUILDING ADDRESS REQUIRED ON PROPER | | | ELEVATION. A MINIMUM OF AT LEAST 6" HIGH | | | NUMBERS ARE REQUIRED. | | | | | | 5. ALL NEW STAIRS AND RAMPS SHALL BE | | | EQUIPPED WITH HANDRAILS ON BOTH SIDES OF | | | THEM. | | | | | | 6. ALL EXIT DOORS ARE TO REMAIN CLEAR | | | AND UNOBSTRUCTED WHILE THE ADDITION IS | | | BEING CONSTRUCTED. | | | | | | 7. COMPLIANCE WITH NFPA 241 IS REQUIRED. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-20 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-20 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2007-08-01 13:30:28 | TO "COMM" BD#27 | | 2007-07-20 09:43:14 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-24 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-24 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | TO "COMM" BD#42 | | 2006-05-24 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-03-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-14 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2005-11-22 00:00:00 | TO "COMM" BD#35 | | 2005-11-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-09 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-08 |
Time |
19:54 |
Sent To |
|
|
| Notes |
| 2007-08-09 12:14:25 | ---------------DENIED----------------- | | | | | | FBC 2004 CODE FAMILY | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS COMMENTS FOR THE PURPOSE OF CONTINUITY. | | | | | | NOTE: NO WRITTEN RESPONSE TO PREVIOUS REVIEW COMMENTS | | | WAS FOUND IN THIS SUBMITTAL PACKAGE. | | | | | | 1. OK | | | | | | 2. OK | | | | | | 3. RELOCATING CONDENSER STANDS: IS THIS NO LONGER PART | | | OF THE SCOPE OF THIS PERMIT? NO INFORMATION WAS FOUND | | | ON PLANS OR IN SUBMITTAL PACKAGE. PLEASE CLARIFY. A | | | NARRATIVE OR WRITTEN RESPONSE TO PREVIOUS RVIEW | | | COMMENTS WILL HELP IN EXPEDITING THE REVIEW PROCESS. | | | | | | 4. PG 6.2: DRAWING OF "SHIP'S LADDER" SHOWS THE LATTER | | | STARTING AT 6 FEET ABOVE GRADE. THE EXTENT OF THE | | | LADDER SHALL BE FROM GRADE OR FLOOR LEVEL TO THE | | | EQUIPMENT'S LEVEL SERVICE SPACE. SEE FBC,M 306.5. | | | | | | 5. NO OUTDOOR AIR INFORMATION COULD BE FOUND ON PLANS. | | | PROVIDE OCCUPANCY CLASSIFICATION, OCCUPANT LOAD, | | | OUTDOOR AIR REQUIRED PER OCCUPANT AND THE AMOUNT OF | | | OUTDOOR AIR TO BE PROVIDED IN ACCORDANCE WITH FBC,M | | | TABLE 403.3. ALSO, PROVIDE INFORMATION FOR TOILET ROOM | | | EXHAUST FANS SUCH AS MODEL # AND CFM. | | | | | | 6. ENERGY CALCULATIONS: | | | A) ON THE PROJECT SUMMARY PAGE, PLEASE INCLUDE ALL | | | AVAILABLE INFORMATION IN THE GIVEN FIELDS. MISSING ON | | | THIS FORM ARE THE OWNER NAME AND THE PERMIT NUMBER. | | | B) CALCULATION PROCEDURES SHALL BE PREPARED, SIGNED AND | | | SEALED BY AN ARCHITECT OR ENGINEER REGISTERED IN | | | FLORIDA PER FBC 13-400.3.ABC.1. | | | C) THE BUILDING?S OWNER, THE OWNER?S ARCHITECT, OR | | | OTHER AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER | | | SHALL CERTIFY TO THE BUILDING OFFICIAL THAT THE | | | BUILDING IS IN COMPLIANCE WITH THE REQUIREMENTS OF | | | CHAPTER 13 OF THIS CODE PRIOR TO RECEIVING THE PERMIT | | | TO BEGIN CONSTRUCTION OR RENOVATION. THE PARTY | | | RESPONSIBLE UNDER SUBSECTIONS 471.003 AND 481.228 AND | | | CHAPTER 489, FLORIDA STATUTES, FOR THE DESIGN AND | | | SPECIFICATION OF EACH BUILDING SYSTEM SHALL CERTIFY | | | THAT THE PLANS AND SPECIFICATIONS FOR THAT SYSTEM | | | COMPLY WITH THE REQUIREMENTS OF CHAPTER 13 OF THIS CODE | | | (SEE ALSO SECTION 13-103.2). | | | D) WALL TYPE ON INPUT DATA REPORT CALLS FOR 8 INCH | | | LIGHTWEIGHT CONCRETE BLOCK. IF THIS TYPE OF BLOCK IS TO | | | BE USED FOR AN ENERGY CREDIT IT MUST BE SPECIFIED ON | | | PLANS. | | | E) PG 4.1 GENERAL NOTE #22 CALLS FOR MINIMUM R-5 | | | INSULATION ON ALL CBS WALLS. ADJUST CALCULATIONS TO | | | CORRESPOND WITH PLANS. | | | F) PG 4.1 GENERAL NOTE #22 CALLS FOR R-19 BATT | | | INSULATION ON CEILINGS IN ALL CONDITIONED SPACES. DOES | | | THIS SPACE HAVE A CEILING? WHERE AND HOW WILL THIS | | | INSULATION BE INSTALLED? ADJUST INPUT DATA REPORT TO | | | CORRESPOND WITH THE ACTUAL ROOF/INSULATION TYPE TO BE | | | USED. PLA DOES NOT SHOW A BUILT-UP GRAVEL ROOF. | | | | | | 7. OK | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-19 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-19 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2006-07-19 00:00:00 | DENIED:2004 FBC | | | COMMENTS FROM REVIEW DATED 1-25-06 | | | | | | COMMENT #1:OK | | | COMMENT #2:PLAN SHEET 9.1 ROOF CURB | | | DETAIL INDICATES 8" FROM THE BAR JOIST | | | FLANGE TO THE FLASHING.PER THE 2004 | | | FBC 1509.7, ROOF CURBS SHALL EXTEND 8" | | | ABOVE THE ROOF SURFACE NOT THE BAR | | | JOIST. | | | | | | COMMENT #3:PLEASE PROVIDE A DETAIL FOR | | | THE RELOCATED CONDENSING UNIT STANDS. | | | PLEASE SHOW COMPLIANCE WITH 2004 FBC | | | TABLE 1509.7. | | | | | | COMMENT #4:PLAN SHEET 6.2 INDICATES A | | | SHIPS LADDER WILL BE INSTALLED ON THE | | | WALL WHERE THE LOWER EXISTING ROOF MEETS | | | THE NEW HIGHER ROOF.PLAN DOES NOT | | | INDICATE ACCESS TO EXISTING ROOF. | | | PLEASE ANNOTATE EXISTING ROOF ACCESS. | | | | | | COMMENT #5: PLEASE PROVIDE OUTSIDE AIR | | | CALUCALTIONS IN ACCORDANCE WITH 2004 FMC | | | TABLE 403.3. | | | | | | *****************NEW COMMENTS*********** | | | 6.ENERGY CALCULATION FORM SUBMITTED IS | | | NOT THE PROPER FORM.COMPLIANCE | | | CALCULATIONS ARE THOSE UTILIZED IN THE | | | ENERGY GAUGE FLA/COM COMPUTER PROGRAM. | | | | | | 7.PLEASE PROVIDE DUCT AND GRILL SIZES. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-25 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-25 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-25 |
Time |
06:24 |
Sent To |
|
|
| Notes |
| 2006-01-25 00:00:00 | DENIED:2004 FLORIDA BUILDING CODE | | | | | | 1.PLAN SHEET 9.1 GENERAL HVAC NOTE #2 | | | INDICATES 2001 FBC.WE ARE CURRENTLY IN | | | THE 2004 FBC. | | | | | | 2.PLAN SHEET 6.2, DETAIL FOR THE CURB. | | | PLANS DO NOT INDICATE ATTACHMENT TO THE | | | ROOF DECK.PLEASE NOTE, ROOF CURBS | | | SHALL BE A MINIMUM OF 8" ABOVE THE ROOF | | | SURFACE PER 2004 FBC 1509.7. | | | | | | 3.PLANS DO NOT PROVIDE A DETAIL FOR | | | THE STANDS FOR THE EXISTING CONDENSING | | | UNITS THAT WERE RELOCATED TO THE | | | EXISTING ROOF.HEIGHT OF THE STANDS | | | SHALL COMPLY WITH TABLE 1509.7 OF THE | | | 2004 FBC. | | | | | | 4.PLEASE INDICATE HOW THE EQUIPMENT | | | LOCATED ON THE ROOF WILL BE ACCESSED FOR | | | SERVICE, MAINENTANCE OR REPLACEMENT. | | | SHOW COMPLIANCE WITH 2004 FMC 306.5, | | | EQUIPMENT LOCATED ON ROOFS WITH AN | | | ELEVATION OF 16FT OR GREATER SHALL HAVE | | | A PERMANENT MEANS OF ACCESS. | | | | | | 5.PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS IN ACCORDANCE WITH 2004 FMC | | | TABLE 403.3. | | | | | | 6.FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | | SHALL HAVE NOTIFICATION TO ALARM/STROBE | | | IN NORMALLY OCCUPIED AREAS PER 2004 FMC | | | 606.4.1 EXCEPTION #2. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-08-30 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-08-30 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2007-08-30 17:53:57 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | ****FROM PREVIOUS REVIEWS: | | | | | | 1. APPLICATION DESCRIPTION OF PROJECT | | | INDICATES "ADDITION ONTO EXISTING BLDG." | | | PLANS INDICATE ALTERATION OF EXISTING | | | BLDG. ALSO. PLEASE DESCRIBE PROJECT IN | | | DETAIL ON APPLICATION AS REQUIRED. | | | ****NEW APPLICATION INDICATES "NEW BUILDING" AND NO | | | MENTION OF EXTERIOR REMODEL AS INDICATED ON SHT 2.1 (3 | | | OF 4 SHEETS). PLEASE DESCRIBE THE PROJECT IN DETAIL AS | | | REQUIRED ON APPLICATION. | | | | | | 2. OK | | | 3. OK | | | 4. SHT 8.2 RESTROOM ELEVATIONS. SHOW | | | COMPLIANCE WITH THE FOLLOWING: | | | FOR W/C'S: | | | A. 11-4.16.2 OK | | | B. 11-4.16.3 OK | | | C. 11-4.16.4 OK | | | D. 11-4.16.5 FLUSH CONTROLS ****NOT ADDRESSED | | | FOR LAVS: | | | A. 11-4.19.2 OK | | | B. 11-4.19.3 OK | | | FOR TOILET ROOMS: | | | A. OK | | | 5. OK - NO WORK IN BREAKROOM | | | 6. SUBMIT A DETAIL FOR THE DRINKING | | | FOUNTAIN SHOWING THE FOLLOWING: | | | A. 11-4.15.2 OK | | | B. 11-4.15.3 OK | | | C. 11-4.15.4 OK | | | D. 11-4.15.5 OK | | | E. 11-4.1.3(10)(A) OK | | | 7. OK | | | 8. OK | | | | | | 9. SUBMIT A WATER RISER DIAGRAM SHOWING | | | ALL PIPE SIZES, VALVES AND WATER HAMMER | | | ARRESTORS IF REQUIRED BY SECTION 604.9. | | | (AIR CHAMBERS ARE NOT APPROVED). SECTION 106.3.5.1.3. | | | ****RESPONSE NOTED, BUT THE HOSE BIBB IS NOT INDICATED | | | ON THE WATER RISER DIAGRAM, AND THE RISER DIAGRAM DOES | | | NOT REFLECT THE PIPE SIZE REQUIRED FOR THE W/C'S | | | INDICATED IN THE FIXTURE CONNECTION SCHEDULE SHOWN ON | | | SHT 11.1. PLEASE CORRELATE INFORMATION. (SHUT OFF VALVE | | | REQUIRED ON SUPPLY LINE TO HOSE BIBB PER SECTION | | | 606.2(2)). | | | | | | 10. OK | | | 11. OK | | | 12. OK | | | 13. OK | | | 14. SEPARATE IRRIGATION PLANS AND PERMIT | | | REQUIRED. SECTION 106.3.5.1.3. (INFORMATIONAL). | | | 15. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | REMOVE ALL VOIDED SHEETS AND RESUBMIT | | | ONE SET FOR COMPARISON. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-02 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-02 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-02 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2006-07-02 00:00:00 | PAUL SCHMITZ | | | [email protected] | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | UNSAT | | | | | | 1) SHT 6.2 ROOF DRAINS SEC. 1107.2 | | | SEPERATE SYSTEMS.SECONDARY ROOF DRAIN | | | SYSTEMS SHALL HAVE THE END POINT OF | | | DISCHARGE, SEPERATE FROM THE PRIMARY | | | SYSTEM. | | | | | | 2) SHT 11.1 RTU A/C CONDENSATE,REFERENCE | | | TO CIVIL DRAWINGS. PROVIDE A DETAIL | | | SHOWING POINT OF DISPOSAL. | | | | | | 3) SHT 11.1 WATER RISER: SEC 606.1 (4) | | | FULLY OPEN VALVES, SHALL BE LOCATED AT | | | THE TOP OF EVERY WATER DOWN FEED PIPE. | | | | | | 4)SHT 4.1 PRIVATE BATH: SEC 11-4.1.3 | | | TOILET FACILITIES, PRIVATE TOILET ROOM | | | FOR THE OCCUPANT OF A PRIVATE OFFICE, | | | SHALL BE ADAPTABLE. | | | | | | 5) NOTES FROM PREVIOUS PLAN REVIEW DATED | | | 2-11-06 NOT ADDRESSED. | | | | | | 1. APPLICATION DESCRIPTION OF PROJECT | | | INDICATES "ADDITION ONTO EXISTING BLDG." | | | PLANS INDICATE ALTERATION OF EXISTING | | | BLDG. ALSO. PLEASE DESCRIBE PROJECT IN | | | DETAIL ON APPLICATION AS REQUIRED. | | | | | | 3. INDICATE THE USE OF THE MEZZANINE, | | | AND INDICATE THE USE OF THE WORKSHOP TO | | | DETERMINE OCCUPANCY. SECTION 106.1.1. | | | | | | 5. SUBMIT A DETAIL FOR THE BREAK ROOM | | | SINK SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD | | | APPROACH REQUIED) | | | E. 11-4.24.6 EXPOSED PIPES & SURFACES | | | F. 11-4.24.7 FAUCETS | | | | | | 7. SHOW PIPE ROUTING FOR THESTORM, AND | | | CONDENSATE. SECTIONS 106.1.1, AND | | | 106.3.5.1.3. | | | | | | 10. SUBMIT A STORM RISER DIAGRAM SHOWING | | | ALL PIPE SIZES AND INDICATE THE SQUARE | | | FOOTAGE DRAINED BY EACH DRAIN. SECTION | | | 106.3.5.1.3. | | | | | | 14. SEPARATE IRRIGATION PLANS AND PERMIT | | | REQUIRED. SECTION 106.3.5.1.3. | | | | | | 15. CODE ADOPTED IN FBC-2004 IN EFFECT | | | SINCE 10-01 2005. PLEASE CHANGE | | | REFERENCES TO CODE TO REFLECT THIS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | REMOVE ALL VOIDED SHEETS AND RESUBMIT | | | ONE SET FOR COMPARISON. | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-02-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-02-11 |
Time |
13:06 |
Rev Time |
2.88 |
| Received By |
kstevens |
Date |
2006-02-11 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2006-02-11 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. APPLICATION DESCRIPTION OF PROJECT | | | INDICATES "ADDITION ONTO EXISTING BLDG." | | | PLANS INDICATE ALTERATION OF EXISTING | | | BLDG. ALSO. PLEASE DESCRIBE PROJECT IN | | | DETAIL ON APPLICATION AS REQUIRED. | | | 2. SHT P4.1 PER TABLE A DRINKING | | | FOUNTAIN IS REQUIRED. | | | 3. INDICATE THE USE OF THE MEZZANINE, | | | AND INDICATE THE USE OF THE WORKSHOP TO | | | DETERMINE OCCUPANCY. SECTION 106.1.1. | | | 4. SHT 8.2 RESTROOM ELEVATIONS. SHOW | | | COMPLIANCE WITH THE FOLLOWING: | | | FOR W/C'S: | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.3 HEIGHT | | | C. 11-4.16.4 GRAB BARS (SHOW LENGTH OF | | | GRAB BAR BEHIND THE W/C) | | | D. 11-4.16.5 FLUSH CONTROLS | | | FOR LAVS: | | | A. 11-4.19.2 HEIGHT & CLEARANCES | | | B. 11-4.19.3 CLEAR FLOOR SPACE | | | FOR TOILET ROOMS: | | | A. TURNING AREA TO BE UNOBSTRUCTED, W/C | | | SHALL NOT BE IN TURNING AREA. SECTION | | | 11-4.22.3 | | | 5. SUBMIT A DETAIL FOR THE BREAK ROOM | | | SINK SHOWING COMPLIANCE WITH THE | | | FOLLOWING: | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD | | | APPROACH REQUIED) | | | E. 11-4.24.6 EXPOSED PIPES & SURFACES | | | F. 11-4.24.7 FAUCETS | | | 6. SUBMIT A DETAIL FOR THE DRINKING | | | FOUNTAIN SHOWING THE FOLLOWING: | | | A. 11-4.15.2 SPOUT HEIGHT | | | B. 11-4.15.3 SPOUT LOCATION | | | C. 11-4.15.4 CONTROLS | | | D. 11-4.15.5 CLEARANCES/CLEAR FLOOR | | | SPACE | | | E. 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | 7. SHOW PIPE ROUTING FOR THE SANT. | | | SYSTEM, WATER PIPING, STORM, AND | | | CONDENSATE. SECTIONS 106.1.1, AND | | | 106.3.5.1.3. | | | 8. SUBMIT A SANITARY RISER DIAGRAM | | | ISOMETRIC SHOW ALL PIPE SIZES, TRAPS, | | | VENTS REQUIRED. SECTION 106.3.5.1.3. | | | 9. SUBMIT A WATER RISER DIAGRAM SHOWING | | | ALL PIPE SIZES, VALVES AND WATER HAMMER | | | ARRESTORS IF REQUIRED BY SECTION 604.9. | | | (AIR CHAMBERS ARE NOT APPROVED). SECTION 106.3.5.1.3. | | | 10. SUBMIT A STORM RISER DIAGRAM SHOWING | | | ALL PIPE SIZES AND INDICATE THE SQUARE | | | FOOTAGE DRAINED BY EACH DRAIN. SECTION 106.3.5.1.3. | | | 11. SUBMIT A CONDENSATE RISER DIAGRAM | | | SHOWING ALL PIPE SIZE, TRAPS ETC. IN | | | ISOMETRIC FORM. | | | 12. SHT 6.2 INDICATES 6" ROOF DRAINS | | | WITH SCUPPERS IN PARAPET NEXT TO THE | | | DRAINS. SHT 8.2 INDICATES DOWNSPOUTS | | | OUTSIDE BLDG WALL. PLEASE CLARIFY. IF | | | ROOF DRAINS ARE DOWNSPOUTS, DOWNSPOUTS | | | SHALL DISCHARGE AT LEAST 1 FOOT AWAY | | | FROM THE STRUCTURE SIDEWALL. PLEASE | | | INDICATE HOW THIS WILL BE ACCOMPLISHED. | | | SECTION 1503.6. | | | 13. RPZV BACKFLOW REQUIRED ON THE WATER | | | SERVICE TO BLDG. | | | 14. SEPARATE IRRIGATION PLANS AND PERMIT | | | REQUIRED. SECTION 106.3.5.1.3. | | | 15. CODE ADOPTED IN FBC-2004 IN EFFECT | | | SINCE 10-01 2005. PLEASE CHANGE | | | REFERENCES TO CODE TO REFLECT THIS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | REMOVE ALL VOIDED SHEETS AND RESUBMIT | | | ONE SET FOR COMPARISON. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2007-08-16 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-08-16 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-08-16 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2007-08-16 08:51:14 | ***FAILED*** | | | | | | PAVING AND DRAINAGE PLANS WERE NOT RESUBMITTED...SOME | | | WERE MADE AT THE TIME OF THE LAST REVIEW AND COULD NOT | | | BE VERIFIED IF THEY HAD BEEN ADDRESSED.ARE THE PAVING | | | AND DRAINAGE PLANS BEING REMOVED FROM THE PACKAGE? | | | PLEASE CLARIFY. | | | | | | 1) THE SITE PLAN AND PAVING AND DRAINAGE | | | PLANS DO NOT CORRESPOND WITH EACH OTHER. | | | | | | 1A) THE SITE PLAN SHOWS 16 PARKING | | | SPACES WHILE THE PANDD PLANS SHOW 15. | | | | | | 1B) THE LOCATION OF THE HC PARKING SPACE | | | DIFFERS BETWEEN THE PLANS. | | | | | | 1C) THE PANDD PLANS SHOW LANDSCAPING IN | | | THE SW CORNER OF THE PARKING LOT, THE | | | SITE PLAN DOES NOT. | | | | | | THE FOLLOWING COMMENTS HAVE NOT BEEN ADDRESSED... | | | | | | 2) THE PARKING DETAIL ON THE SITE PLAN | | | DOES NOT CONFORM TO SECTION 94-485 OF | | | THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (I.E. DOUBLE STRIPING, | | | ETC.). NO DIMENSIONS WERE SHOWN BETWEEN THE STRIPING. | | | SEE THE ATTACHED DETAIL FOR REFERENCE. | | | | | | 4) PLEASE PROVIDE PROOF OF ACCEPTANCE OF | | | THE DUMPSTER LOCATION FROM THE CITY'S | | | SANITATION DEPARTMENT. | | | | | | 8) PLEASE PROVIDE EVIDENCE OF OBTAINING | | | TRAFFIC CONCURRENCY (TRAFFIC CONCURRENCY | | | LETTER) FROM PALM BEACH COUNTY. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | | SENIOR PLANNER, AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-07-18 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-07-18 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2007-07-18 14:18:37 | THE FOLLOWING IS A NOTE ABOUT PERMIT EXPIRATION.IT IS | | | NOT A ZONING PLAN REVIEW: | | | | | | 6/1/07 MET WITH OWNERS AND CRA.CHANGED STATUS FROM | | | EXPIRED TO OPEN BECAUSE SOME OF THE ZONING COMMENTS | | | WERE ADDRESSED IN MEETINGS AND CORRESPONDENCE BETWEEN | | | THE OWNERS AND PLANNING DEPT.AS CONFIRMATION OF THAT, | | | JOHN ROACH IS TO UPDATE ZONING PLAN REVIEW NOTES TO | | | REFLECT THE FACT THAT SOME OF THE ZONING REVIEW | | | COMMENTS WERE ADDRESSED ON 10/11/06. RB |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-07-17 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2006-07-17 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2006-07-17 |
Time |
11:40 |
Sent To |
|
|
| Notes |
| 2006-07-17 00:00:00 | 7/17/06 ***FAILED*** | | | | | | 1) THE SITE PLAN AND PAVING AND DRAINAGE | | | PLANS DO NOT CORRESPOND WITH EACH OTHER. | | | | | | 1A) THE SITE PLAN SHOWS 16 PARKING | | | SPACES WHILE THE PANDD PLANS SHOW 15. | | | | | | 1B) THE LOCATION OF THE HC PARKING SPACE | | | DIFFERS BETWEEN THE PLANS. | | | | | | 1C) THE PANDD PLANS SHOW LANDSCAPING IN | | | THE SW CORNER OF THE PARKING LOT, THE | | | SITE PLAN DOES NOT. | | | | | | 1D) THE SITE PLAN DOES NOT SHOW A FIVE | | | (5) FOOT LANDSCAPE TERMINAL ISLAND, WITH | | | SHADE TREE, AT THE NE CORNER OF THE | | | PARKING LOT.THIS IS REQUIRED. | | | | | | 1E) NO DRIVEWAY APPROACH IS SHOWN ON THE | | | SITE PLANS. | | | | | | 2) THE PARKING DETAIL ON THE SITE PLAN | | | DOES NOT CONFORM TO SECTION 94-485 OF | | | THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS (I.E. DOUBLE STRIPING, | | | ETC.). | | | | | | 3) THE SITE PLAN DOES NOT PROVIDE A DATA | | | TABLE INDICATING PARKING CALCULATIONS, | | | IMPERVIOUS, PERVIOUS, BUILDING SQUARE | | | FOOTAGE, ETC. | | | | | | 4) PLEASE PROVIDE PROOF OF ACCEPTANCE OF | | | THE DUMPSTER LOCATION FROM THE CITY'S | | | SANITATION DEPARTMENT. | | | | | | 5) THE SE CORNER OF THE PARKING LOT | | | SHALL BE CURBED AND LANDSCAPED WITH AT | | | LEAST ONE (1) SHADE TREE. | | | | | | 6) THE PROPOSED BUILDING ENCROACHES INTO | | | THE VISIBILITY TRIANGLE (20 FEET X 20 | | | FEET) AT THE CORNER. | | | | | | 7) PLEASE PROVIDE PHOTOMETRIC PLAN OF | | | THE EXTERIOR LIGHTING.PHOTOMETRIC | | | LEVELS SHALL NOT EXCEED 0.5 FOOTCANDLES | | | WHEN MEASURED IN A RESIDENTIAL ZONING | | | DISTRICT (I.E. WEST PROPERTY LINE). | | | | | | 8) PLEASE PROVIDE EVIDENCE OF OBTAINING | | | TRAFFIC CONCURRENCY (TRAFFIC CONCURRENCY | | | LETTER) FROM PALM BEACH COUNTY. | | | | | | 9) A SCREEN WALL SHALL BE BUILT ALONG | | | THE WEST PROPERTY LINE, SEPARATING THE | | | NONRESIDENTIAL USE FROM THE ADJACENT | | | RESIDENTIAL ZONING DISTRICT. | | | | | | 10) LANDSCAPE PLANS SHALL BE SUBMITTED | | | AN SHALL BE CONSISTENT WITH THE SITE | | | PLAN. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | | SENIOR PLANNER, AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-01-12 |
|
|
Cont ID |
|
| Sent By |
gjoyce |
Date |
2006-01-12 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
gjoyce |
Date |
2006-01-12 |
Time |
09:52 |
Sent To |
|
|
| Notes |
|
|
|