Plan Review Details - Permit 05110182
| Plan Review Stops For Permit 05110182 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-22 |
Time |
07:11 |
Rev Time |
0.78 |
| Received By |
jwitmer |
Date |
2005-12-22 |
Time |
07:11 |
Sent To |
PC |
|
| Notes |
| 2005-12-22 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05110182 | | | ADD: 220 SUNSET RD | | | CONT: GUSTASON INDUSTRIES | | | TEL: (561)732-0656 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW: | | | ACTION: REVIEWED | | | | | | BUILDING PROVISO: | | | NOTE: IF ANY QUESTIONS PLEASE CALL | | | REVIEWER, WITHIN WPB JURISDICTION, YOU | | | WILL RECIEVE SAME REVIEWER AS FROM THE | | | FIRST REVIEW, NEW STANDARD TO HELP | | | EXPEDITE PERMIT. | | | | | | 1) VALENCIA SPANISH "S" CONCRETE TILE, | | | SEE SYSTEMS LIMITATION: | | | POLYGLASS: | | | POLYSTICK UNDERLAYMENT: | | | 7. POLYSTICK TU, TU PLUS OR MU TO BE | | | USED FOR ADHESIVE SET ROOF TILE. | | | TILE PROFILE POLYSTICK MU, TU PLUS ARE | | | LIMITED TO A MAXIMUM SLOPE OF 5:12. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-08 |
Time |
16:13 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2005-11-08 |
Time |
16:13 |
Sent To |
PC |
|
| Notes |
| 2005-11-08 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05110182 | | | ADD: 220 SUNSET RD | | | CONT: GUSTASON | | | TEL: (561)732-0656 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW: | | | ACTION: DENIED | | | | | | 1) ENTEGRA VALENCIA SPANISH "S", | | | INDICATE TYPE OF FASTENING DEVISE, THE | | | MINIMUM REQUIRED AERODYNAMIC UPLIFT | | | MOMENT MF=(FT-LBF) 26.1. HIGHLIGHT WHICH | | | APPLICATION WILL BE USED. | | | | | | 2) TARCO ROOFING UNDERLAYMENT SUBMITTED | | | IS UNDER THE 2001 CODE NOT 2004. THE | | | PRODUCT INFORMATION SUBMITTED DOES NOT | | | HAVE THE PRESSURES TESTED FOR. | | | | | | 3) MULE-HIDE MODIFEID UNDERLAYMENT HAS A | | | LIMITATION # 9, GOOD FOR ONLY -45 LBS. | | | THERE CAN BE NO ENHANCED NAILING IN ANY | | | ZONE. END ZONE HAVE A MINIMUM PRESSURE | | | OF -89.0. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | |
|
|
|