Plan Review Details - Permit 05110145
Plan Review Stops For Permit 05110145
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-12-22 Cont ID  
Sent By shill Date 2005-12-22 Time 13:38 Rev Time 1.00
Received By shill Date 2005-12-22 Time 12:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-11-05 Cont ID  
Sent By shill Date 2005-11-05 Time 18:25 Rev Time 1.50
Received By shill Date 2005-11-05 Time 13:27 Sent To P
Notes
2005-11-05 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 1.)PROVIDE AREA CALCULATIONS FOR THE
 EXISTING POOL AND WADING POOL.
  
 2.)PROVIDE A BASIC LAYOUT OF THE "BATH
 HOUSE"; DOORS (TO BE ACCESSED FROM THE
 WET PLAY AREA) AND FIXTURE COUNT TO SHOW
 COMPLIANCE WITH FAC64E-9.006(2)(F) IN
 REGARDS TO SANITARY FACILITIES.
  
 3.)SEE PLUMBING REVIEWER'S NOTES IN
 REGARDS TO APPLICATION TO THE DEPARTMENT
 OF HEALTH.APPROVAL REQUIRED PRIOR TO
 PERMIT ISSUANCE, FAC64E-9.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2005-12-22 Cont ID  
Sent By dpalmer Date 2005-12-22 Time 15:31 Rev Time 0.00
Received By dpalmer Date 2005-12-22 Time 15:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-11-07 Cont ID  
Sent By dpalmer Date 2005-11-07 Time 08:28 Rev Time 0.00
Received By dpalmer Date 2005-11-07 Time 08:28 Sent To  
Notes
2005-11-07 00:00:00**** UNSAT ****
  
  
  
 PLEASE KNOW PLANS, ARE COMING BACK FOR
 COMMENTS FROM OTHER REVIEWERS, PLEASE
 MAKE THE BELOW CORRECTIONS AT THIS TIME.
  
 1)NOTE: PLEASE SEE 250.6,250.24 THERE IS
 NO EQUIPMENT GROUNDING CONDUCTOR TO BE
 INSTALLED UNTIL AFTER THE FRIST MEANS OF
 DISCONNECT.
  
 2)NOTE: PLEASE SEE PLANS CALL FOR A
 CONNECTION TO CITY WATER, HOWEVER THERE
 IS NO CONNECTIONS SHOWN ON THE GROUNDING
 ELECTRODE SYSTEM FOR COLD WATER/ BOND
 ETC. PLEASE SEE 250.50,250.104 ETC.
  
 3)NOTE: PLEASE SUBMIT THE SPECS, CUT
 SHEETS ON THE FOUNTAIN/ CONTROLLER.
 PLEASE BE SURE SPECS INCLUDE A LISTING
 BY A NRTL, NATIONALLY RECOGNIZED TESTING
 LABORTORY.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESIATE IN CONTACTING THIS
 OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2005-11-07 Cont ID  
Sent By shill Date 2005-11-07 Time 14:27 Rev Time  
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2005-12-22 Cont ID  
Sent By adarroug Date 2005-12-22 Time 08:45 Rev Time 0.00
Received By adarroug Date 2005-12-22 Time 08:44 Sent To B
Notes
2005-12-22 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-12-14 Cont ID  
Sent By adarroug Date 2005-12-14 Time 13:06 Rev Time 0.00
Received By adarroug Date 2005-12-14 Time 13:06 Sent To B
Notes
2005-12-14 00:00:00TO "LMARTINEZ" DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-11-07 Cont ID  
Sent By shill Date 2005-11-07 Time 14:27 Rev Time 0.00
Received By shill Date 2005-11-04 Time 18:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2005-12-14 Cont ID  
Sent By pschmitz Date 2005-12-14 Time 10:34 Rev Time 0.00
Received By pschmitz Date 2005-12-14 Time 10:33 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-11-07 Cont ID  
Sent By pschmitz Date 2005-11-07 Time 07:11 Rev Time 0.00
Received By pschmitz Date 2005-11-06 Time 08:55 Sent To  
Notes
2005-11-06 00:00:00PAUL SCHMITZ
 FBC 2004 PLUMBING CODE PLAN REVIEW
 FBC 2004 CH 11, FL ACESSIBILITY CODE
 DENIED
 1) FAC 64E-9 PUBLIC POOLS AND WATER
 FEATURES, REQIURE PALM BEACH COUNTY
 HEALTH DEPARTMENT PLAN REVIEW PRIOR TO
 WEST PALMM BEACH, CONSTRUCTION SERVICES
 PLAN REVIEW.
 CONTACT:
 DUTCH HOLLAND 561-355-3070 X 1134
  
 2) SEC 424.1.6.1 SANITARY FACILITIES.
 REQUIRED FIXTURES SHALL BE PROVIDED AS
 INDICATED ON TABLE 424.1.6.1
 SHOW THE EXISTING, AND REQUIRED
 FACILITIES FOR THE ADDITION OF THE
 SPOLASH FEATURE, AND HOW THIS WILL
 EFFECT THE DELETION OF OF EXISTING
 FIXTURES.
 3)SHT ASP-1 LEGEND "H" TO MUNICIPAL
 DRAIN.
 SEC 1002.5 SIZE OF FIXTURE TRAPS.
 NOT LESS THAN THE SIZE INDICATED ON TAB.
 709.1
 SEC 1002.6 BUILDING TRAPS.
 BUILDING DRAIN TRAPS SHALL BE PROVIDED
 WITH A CLEAN OUT AND RELIEF VENT
 END OF COMMENTS. QUESTIONS 561-805-6692

Review Stop Z ZONING
Rev No 1 Status P Date 2005-11-07 Cont ID  
Sent By mmclean Date 2005-11-07 Time 11:38 Rev Time 0.00
Received By mmclean Date 2005-11-07 Time 11:38 Sent To B
Notes
2005-11-07 00:00:00GIVEN TO ROBERT BROWN.