Plan Review Details - Permit 05110141
Plan Review Stops For Permit 05110141
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2005-11-07 Cont ID  
Sent By jwitmer Date 2005-11-07 Time 13:40 Rev Time 0.55
Received By jwitmer Date 2005-11-07 Time 13:40 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-11-07 Cont ID  
Sent By jwitmer Date 2005-11-07 Time 10:35 Rev Time 0.77
Received By jwitmer Date 2005-11-07 Time 10:35 Sent To PC
Notes
2005-11-07 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05110141
 ADD: 811 44TH ST
 CONT: MARKS ROOF CONTRACTING
 TEL: (561)723-7097
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 ) THIS ROOF IS MISSING OR NOT IN
 COMPLIANCE WITH THE FOLLOW ITEMS:
  
 _X__ CONTRACTOR DID NOT PROVIDE THE MEAN
 ROOF HEIGHT.
  
 ___ CONTRACTOR DID NOT INDICATE THE ROOF
 PITCH.
 _X__CONTRACTORDID NOT SUBMIT PRODUCT
 APPROVAL FOR THE FLAT DECK.
 _X__CONTRACTOR DID'T SUBMIT FLORIDA
 COVERSHEET FOR SHINGLES NOR FLAT ROOF.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 _X__ CONTRACTOR FAILED TO INDICATE WHICH
  
 SYSTEM TO BE USED.
  
 _X__ THE SYSTEM PROVIDED HAS "NO"
 PRESSURE FOR ZONE _1,2&3__
 .SUBMITTAL IS FOR UNDERLAYMENT
  
 _X__ THE SYSTEM PROVIDED STATES
 LIMITATION# 7, SHOULD THE FASTENER
 RESISTANCE BE LESS THAN THAT
 REQUIRED, AS DETERMINED BY THE
 BUILDING OFFICIAL, A REVISED
 FASTENER SPACING, PREPARED , SIGNED
 AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER, REGISTERED
 ARCHITECT OR REGISTERED ROOF
 CONSULTANT MAY BE SUBMITTED.
  
 ___THE SYSTEM PROVIDED INDICATES
 LIMITATION# 9, NO ENHANCED
 FASTENING ALLOWED.
  
 _X__MIAMI-DADE NOA LIMITATIONS 3.6
 POLYSTICK UNDERLAYMENT TO BE EXPOSEDNO
  
 LONGER THAN 30 DAYS.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  