| Plan Review Stops For Permit 05101241 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2006-10-21 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2006-10-21 |
Time |
09:48 |
Sent To |
I |
|
| Notes |
| 2006-10-23 09:56:39 | SEE FRC SECTION R310.4: WHILE HURRICANE PROTECTECTION | | | IS PROVIDED, AT LEAST ONE MEANS OF ESCAPE MUST BE | | | PROVIDED WITHIN THE FIRST FLOOR OF THE DWELLING OR | | | DWELLING UNIT AND SHALL NOT BE LOCATED WITHIN THE | | | GARAGE. OCCUPANTS IN ANY PART OF THE DWELLING OR | | | DWELLING UNIT SHALL BE ABLE TO ACCESS THE MEANS OF | | | ESCAPE WITHOUT PASSING THROUGH A LOCKABLE DOOR NOT | | | UNDER THEIR CONTROL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2006-04-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2006-04-04 |
Time |
15:48 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2006-04-04 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2006-04-04 00:00:00 | BUILDING REVIEW PROVISO: | | | *1- SHEET A-3: A) REVISE TYPE OF | | | CONSTRUCTION. SEE FBC 2004. THERE IS NOT | | | CONSTRUCTION TYPE VI ON 2004 FBC. | | | B) MEAN ROOF HEIGHT IS +/-21'-3", NOT | | | 15'-0. REVISE AS REQUIRED. | | | C) REVISE BUILDING HEIGHT. SEE | | | DEFINITION ON SEC. 502 FBC 2004. | | | D) REVISE/CLARIFY REFERENCE TABLE USED | | | FOR WIND ANALYSIS. WHICH ONE IS TABLE | | | R301.2?. SEE TABLES AND REVISE AS REQ'D. | | | *2- TRUSS DESIGN PACKAGE: A) ENGINEER TO | | | USE CURRENT APPROVED SEAL THAT SAYS | | | "LICENSE" INSTEAD OF "CERTIFICATE" AS | | | REQUIRED BY FLORIDA ADMINISTRATIVE CODE. | | | B) ALL GENERAL DETAILS SUBMITTED WITH | | | TRUSS PACKAGE NEED TO HAVE ENGINEER'S | | | ORIGINAL SEAL, SIGNATURE AND DATE AS | | | REQUIRED BY CHAPTER 471 FLORIDA STATUTE | | | AND FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.002. | | | *3- CONNECTOR SPECIFIED FOR GIRDER TRUSS | | | N1G DOESN'T RESIST THE CALCULATED UPLIFT | | | LOADS. ARCHITECT TO REVISE CONNECTOR. | | | *4- RE-SUBMIT COMPLETE PRODUCT APPROVAL | | | PACKAGE. NEED TO PROVIDE 2004 FLORIDA | | | PRODUCT APPROVAL VERSION, NOT 2001. | | | *5- PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS UNDER A SEPARATE PERMIT. | | | *6- NEED SURVEY WITH ORIGINAL SIGNATURE | | | AS REQUIRED BY CHAPTER 472 FL. STATUTE. | | | *7- ARCHITECT'S REVIEW STAMP USED TO | | | APPROVE PRODUCT APPROVALS DOESN'T HAVE | | | THE ARCHITECT'S NAME OR COMPANY'S NAME | | | ON IT. NEED STAMP THAT IDENTIFIES | | | COMPANY OR ARCHITECT REVIEWING THE | | | PRODUCTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-12-27 |
Time |
17:56 |
Rev Time |
3.00 |
| Received By |
jgomez |
Date |
2005-12-27 |
Time |
17:17 |
Sent To |
Z |
|
| Notes |
| 2005-12-27 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- ALL PLANS SUBMITTED AFTER OCTOBER 1ST | | | 2005 ARE REQUIRED TO COMPLY WITH FBC | | | 2004. REVISE ALL PLANS, GENERAL NOTES, | | | DESIGN PARAMETERS, CONSTRUCTION TYPE AND | | | ALL PERTINENT ITEMS SHOWN ON PLANS AS | | | REQUIRED TO COMPLY WITH FBC 2004. | | | | | | 2- ENERGY CALCS SUBMITTED ARE DONE USING | | | FBC 2001 FORMS. NEED TO REVISE CALCS | | | USING FBC 2004 FORMS. | | | | | | 3- TRUSS DESIGN DRAWINGS NEED TO BE | | | PROVIDED TO THE BUILDING OFFICIAL FOR | | | APPROVAL PRIOR TO INSTALLATION. SEC. | | | R802.10.1 OF RESIDENTIAL FLORIDA | | | BUILDING CODE 2004. (REMAINDER: DESIGNER | | | OF RECORD TO REVIEW ALL TRUSSES PRIOR TO | | | SUBMITTAL TO THIS OFFICE). | | | | | | 4- DESIGNER OF RECORD TO REVIEW ALL | | | PRODUCT APPROVALS PRIOR TO SUBMITTAL TO | | | THIS OFFICE AS REQUIRED BY SEC. 106.3.3 | | | CITY AMENDMENTS TO FBC 2004. | | | ***NOTE: PLEASE, DON'T PUT THE REVIEW | | | STAMP ON THE BACK OF THE PAGE OF THE | | | PRODUCT APPROVAL BECAUSE IT CAN'T BE | | | SCANNED FOR FILING PURPOSES. | | | | | | 5- PROVIDE ALL INFORMATION ON PLANS | | | REGARDING THE GARAGE SEPARATION AS | | | REQUIRED BY SEC. R309 OF THE RESIDENTIAL | | | FBC 2004. | | | | | | 6- PROVIDE FLORIDA OR LOCAL PRODUCT | | | APPROVAL FOR: | | | A) FIXED WINDOWS. | | | ***NOTE: CHECK SIZES SHOWN ON PLANS. EG: | | | SEE BREAKFAST AREA. | | | B) CASEMENT WINDOWS: NOA SUBMITTED | | | DOESN'T MATCH NOA SUBMITTED FOR FLORIDA | | | APPROVAL. ALSO, CLARIFY IF USING IMPACT | | | WINDOWS OR NOT. | | | | | | 7- PROVIDE COMPLETE INFORMATION FOR | | | STORM SHUTTERS. THERE WAS NOT | | | INFORMATION SUBMITTED WITH THIS PACKAGE. | | | SEE ATTACHED INSTALLATION SCHEDULE | | | SAMPLE THAT HELPS TO PROVIDE ALL | | | REQUIRED INFORMATION FOR PLAN REVIEW. | | | | | | 8- AREA CALCS SHOWN ON SHEET A3 DON'T | | | ADD UP. REVISE AS REQUIRED. ALSO, AREA | | | SHOWN ON PERMIT APPLICATION DOESN'T | | | MATCH PLANS. REVISE AS REQUIRED. | | | | | | 9- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-09-11 |
Time |
17:56 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-09-11 |
Time |
17:56 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-24 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-24 |
Time |
18:41 |
Sent To |
PC |
|
| Notes |
| 2006-07-24 00:00:00 | REV FOR AS BUILTS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-03-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-23 |
Time |
17:17 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-23 |
Time |
17:01 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-21 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-17 |
Time |
08:07 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-25 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-25 |
Time |
09:35 |
Sent To |
E |
|
| Notes |
| 2006-08-25 00:00:00 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-24 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-24 |
Time |
09:52 |
Sent To |
E |
|
| Notes |
| 2006-07-24 00:00:00 | TO "E" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-21 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-21 |
Time |
12:03 |
Sent To |
E |
|
| Notes |
| 2006-03-21 00:00:00 | TO BT'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-03 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-03 |
Time |
10:12 |
Sent To |
Z |
|
| Notes |
| 2006-03-03 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-03 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-14 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-24 |
Time |
09:34 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-03-24 |
Time |
09:34 |
Sent To |
P |
|
| Notes |
| 2006-03-24 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND | | | CUSTOMER VOIDED MECHANICAL PERMIT NUMBER | | | 05101244 AND WILL APPLY FOR LATER AND | | | SUBMIT MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-21 |
Time |
11:11 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-11-21 |
Time |
11:11 |
Sent To |
P |
|
| Notes |
| 2005-11-21 00:00:00 | *** DENIED *** | | | NO MECHANICAL PLANS SUBMITTED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-24 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-03-24 |
Time |
10:42 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-21 |
Time |
18:30 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-11-21 |
Time |
18:30 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-03-17 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-03-17 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-03-17 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-01-03 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-01-03 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | ZONING REVIEW COMMENTS: | | | 1.ORIENTATION OF BUILDING FOOTPRINT ON | | | SURVEY DOES NOT MATCH ACTUAL FLOOR PLAN. | | | REVISE DRAWINGS ACCORDINGLY. | | | | | | 2. PROVIDE A LOCATION MAP ON BOTH SURVEY | | | AND ARCHITECTURAL CONSTRUCTION | | | DOCUMENTS' COVER PAGE. (I.E INCLUDE WHAT | | | "POD", TRACT OF IBIS GOLF & COUNTRY CLUB | | | MASTER PLAN THIS LOT 21 BELONGS TO). |
|
|