Plan Review Details - Permit 05101198
| Plan Review Stops For Permit 05101198 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-01-26 |
Time |
11:24 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-01-26 |
Time |
07:47 |
Sent To |
Z |
|
| Notes |
| 2006-01-26 00:00:00 | | | | PROVISO | | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW PRIOR TO CALLING INSPECTION. | | | | | | | | | 1} 445.13 AMPACITY OF CONDUCTORS. | | | THE AMPACITY OF THE CONDUCTORS FROM THE | | | GENERATOR TERMINALS TO THE FIRST | | | DISTRIBUTION DEVICE(S) CONTAINING | | | OVERCURRENT PROTECTION SHALL NOT BE LESS | | | THAN 115 PERCENT OF THE NAMEPLATE | | | CURRENT RATING OF THE GENERATOR. | | | | | | 2} THE FEEDER FROM THE ATS TO THE | | | "EMERGENCY" PANEL ALSO MUST COMPLY WITH | | | 310.15. THE OCP MUST BE DECREASED OR THE | | | CONDUCTOR SIZE INCREASED.I FTHERE ARE | | | ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2005-11-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-18 |
Time |
12:03 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-18 |
Time |
11:29 |
Sent To |
PC |
|
| Notes |
| 2005-11-18 00:00:00 | | | | A RESIDENTIAL GENERATOR PERMIT MUST BE | | | APPLIED FOR BEFORE THE ELECTRICAL OR | | | FUEL PERMITS CAN BE ISSUED. | | | | | | PLEASE SUBMIT MANUFACTURERS | | | SPECIFICATIONS FOR THE EQUIPMENT BEING | | | INSTALLED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-02 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-02 |
Time |
14:44 |
Sent To |
M |
|
| Notes |
| 2006-02-02 00:00:00 | TO "GEN-RES" BOX "M" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-22 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-22 |
Time |
12:18 |
Sent To |
E |
|
| Notes |
| 2005-10-22 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-07 |
Time |
08:47 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-02-07 |
Time |
08:47 |
Sent To |
E |
|
| Notes |
| 2006-02-07 00:00:00 | *** PROVISO *** | | | 1)GENERATOR EXHUST MUST BE TEN FEET AWAY | | | FROM ANY BUILDING OPENINGS (WINDOWS, | | | DOORS, ROOF & EAVE VENTS), AND TEN FEET | | | AWAY FROM ADJECENT BUILDING OPENS. PER | | | 2004 FBC/M 401.5.1 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-31 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-31 |
Time |
17:42 |
Sent To |
I |
|
| Notes |
|
|
|