Plan Review Details - Permit 05101119
| Plan Review Stops For Permit 05101119 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2005-12-20 |
Time |
09:24 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2005-12-20 |
Time |
09:24 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2005-11-28 |
Time |
09:29 |
Rev Time |
0.50 |
| Received By |
amorse |
Date |
2005-11-28 |
Time |
09:29 |
Sent To |
PC |
|
| Notes |
| 2005-11-28 00:00:00 | DENIED | | | | | | | | | | | | | | | 1) CONTRACTOR FAILED TO PROVIDE THE | | | FLORIDA STATE APPROVAL COVER SHEETS THEY | | | MUST BE SUPPLIED WITH THE NOA'S (2 | | | COPIES) | | | THESE ARE THE PAGES WITH THE FL #'S ON | | | THEM. (EG.) GAF BUILT UP ROOF IS | | | FL618-R1 | | | | | | 2) IN THE NOA FOR POLYGLASS USA INC. | | | THE ONLY PRODUCT THAT CAN BE USED ON A | | | ROOF SLOPE ABOVE 5/12 IS POLYSTICK TU | | | (SEE LIMITATION 7) | | | YOUR APPLICATION SPECIFIES TU PLUS AND | | | CANNOT BE USED ABOVE A 5/12 SLOPE | | | | | | 3) ALMAR (USA), INC. IS NOT IN THE | | | FLORIDA STATE APPROVAL SYSTEM BUT | | | ALTUSA TILE IS UNDER THE 2001 VERSION WE | | | WILL ACCEPT THIS APPROVAL WITH THE | | | ACCOMPANING SBCCI/ICC ES LEGACY REPORT # | | | 9914 | | | | | | NOTE: AN UPDATED COPY OF THIS REPORT IS | | | AVAILABLE ON THE WEB SITE | | | WWW.ICC-ES.ORG/EVALUATION_REPORTS/INDEX. | | | SHTML | | | | | | | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | (561)805-6716 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2005-10-20 |
Time |
10:59 |
Rev Time |
0.33 |
| Received By |
jgomez |
Date |
2005-10-20 |
Time |
10:58 |
Sent To |
PC |
|
| Notes |
| 2005-10-20 00:00:00 | BUILDING REVIEW CHECKLIST: | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. | | | | | | 2- PROVIDE FLORIDA PRODUCT APPROVAL OR | | | LOCAL PRODUCT APPROVAL FOR A) FLAT ROOF | | | SYSTEM. B) CLAY ROOF TILE. C) POLYFOAM | | | AS REQUIRED BY RULE 9B-72 OF DCA. SEE | | | WWW.FLORIDABUILDING.ORG. | | | DADE COUNTY NOA ALONE IS NOT | | | AUTOMATICALLY AN STATE WIDE FLORIDA | | | PRODUCT APPROVAL. IF THERE IS NOT | | | FLORIDA PRODUCT APPROVAL, MANUFACTURER | | | MAY APPLY FOR LOCAL PRODUCT APPROVAL | | | USING THE DADE COUNTY NOA AND COMPLETING | | | THE LOCAL PRODUCT APPROVAL FORM | | | DOWNLOADED FROM WWW.FLORIDABUILDING.ORG. | | | | | | 3- POLISTICK CAN NOT BE USED FOR ROOF | | | TILE UNDERLAYMENT. SEE LIMITATION #2 ON | | | PAGE 4 OF 5 OF DADE COUNTY NOA SUBMITTED | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-19 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-19 |
Time |
16:56 |
Sent To |
B |
|
| Notes |
| 2005-12-19 00:00:00 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-28 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-28 |
Time |
08:29 |
Sent To |
B |
|
| Notes |
| 2005-11-28 00:00:00 | TO "AMORSE" DESK |
|
|
|