Plan Review Details - Permit 05100947
Plan Review Stops For Permit 05100947
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-08-08 Cont ID  
Sent By alange Date 2006-08-08 Time 08:31 Rev Time 1.66
Received By alange Date 2006-08-08 Time 08:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-07-10 Cont ID  
Sent By alange Date 2006-07-10 Time 10:44 Rev Time 1.00
Received By alange Date 2006-07-10 Time 09:45 Sent To  
Notes
2006-07-10 00:00:00DENIED
  
 1.713.13(2) F.S.THE NOTICE OF
 COMMENCEMENT MUST BE RE-RECORDED BECAUSE
 THE DESCRIBED IMPROVEMENT OR
 CONSTRUCTION DID NOT COMMENCE WITHIN 90
 DAYS OF RECORDING.
  
 2.PRODUCT APPROVALS REQUIRED FOR OVER
 HEAD DOOR.
  
  
 3.ALL PLANS SUBMITTED AFTER OCTOBER,
 1, 2005 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.CORRECT CODE
 SECTIONS USED AND CHANGE WIND DESIGN TO
 ASCE 7-02.
  
 4.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-06-12 Cont ID  
Sent By alange Date 2006-06-12 Time 10:44 Rev Time 0.66
Received By alange Date 2006-06-12 Time 10:28 Sent To  
Notes
2006-06-12 00:00:00DENIED
  
 3.SIGN OWNER/AGENT ON ENERGY CALCS.
  
 5.SUBMIT PRODUCT APPROVALS FOR
 HARDIE-PLANK SIDING.INFORMATION
 SUBMITTED IS A PRODUCT INFO GUIDE.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-02-07 Cont ID  
Sent By alange Date 2006-02-07 Time 09:06 Rev Time 1.00
Received By alange Date 2006-02-07 Time 09:06 Sent To  
Notes
2006-02-07 00:00:00DENIED
  
 3.SIGN OWNER/AGENT ON ENERGY CALCS.
  
 5.SUBMIT PRODUCT APPROVALS FOR
 HARDIE-PLANK SIDING.INFORMATION
 SUBMITTED IS A PRODUCT INFO GUIDE.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-15 Cont ID  
Sent By alange Date 2005-12-15 Time 07:27 Rev Time 2.00
Received By alange Date 2005-12-15 Time 07:27 Sent To  
Notes
2005-12-15 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS FS. 472.025
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS.
  
 5.SUBMIT PRODUCT APPROVALS FOR LINTELS
 AND HARDIE-PLANK SIDING WITH THE
 FOLLOWING STATE PRODUCT APPROVAL
 ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6.ALL PLANS SUBMITTED AFTER OCTOBER 1,
 2005 SHALL BE DESIGNED TO THE 2004 FBC.
  
 ANY QUESTIONS CALL ME.
  
 ART LANGE
 BUILIDNG PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-01-11 Cont ID  
Sent By btrobaug Date 2007-01-11 Time 15:03 Rev Time 0.50
Received By btrobaug Date 2007-01-11 Time 13:08 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-08-07 Cont ID  
Sent By btrobaug Date 2006-08-07 Time 14:27 Rev Time 0.50
Received By btrobaug Date 2006-08-07 Time 13:44 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-07-05 Cont ID  
Sent By btrobaug Date 2006-07-05 Time 12:57 Rev Time 0.50
Received By btrobaug Date 2006-07-05 Time 12:18 Sent To M
Notes
2006-07-05 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE SERVICE ENTRANCE CONDUCTORS FOR
 200 AMPS MUST BE A MINIMUM OF 2/0
 COPPER, 310.15(B)(6).
  
 2} CIRCUIT #18, #12WIRE ON A 30 AMP
 BREAKER DOES NOT COMPLY WITH 310.16.
  
 3} THE COOKTOP AND THE AHU HAVE
 INCORRECT OCP AND WIRE SIZE FOR THE
 RESPECTIVE LOADS.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-05-30 Cont ID  
Sent By btrobaug Date 2006-05-30 Time 08:57 Rev Time 1.00
Received By btrobaug Date 2006-05-30 Time 06:50 Sent To M
Notes
2006-05-30 00:00:00 
 NONCOMLPIANT
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE INDICATE THE LOCATION OF THE
 PANEL SHOWN ON THE RISER, ON THE PLAN.
  
 2} THE FEEDER FROM THE MAIN TO THE PANEL
 IS INCORRECT FOR A 200 AMP SERVICE. SEE
 310.15(B)(6).
  
 3}PER 110.9 AND 110.10: OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT.
  
 4} THE 80 AMP OCP IS TOO LARGE FOR THE
 CONDUCTORS FEEDONG THE AHU'S. SEE
 310.16. ALSO SEE CIRCUITS 2,4 IS
 MISMARKED "A/C".
  
 5} CIRCUIT #15 MARKED "FUTURE POOL PUMP"
 SHOWS 2500 WATTS ON A 20 AMP BREAKER,
 PLEASE CORRECT.
  
 6} CIRCUIT #17 MARKED "FUTURE POOL
 HEATER" @ 1200 WATTS SEEMS INCORRECT.
 TYPICALLY THESE HEATERS ARE NO SMALLER
 THAN 5000 WATTS @ 240 VOLTS.
  
 7} PLEASE CORRECT CIRCUIT #9 & 11, 30AMP
 OCP FOR 10000 WATTS.
  
 8} THERE ARE RECEPTACLES MISSING FROM
 THE BEDROOM(#2)AND THE NEW BEDROOM.
 210.52(A).
  
 9} A RECEPTACLE PER 210.52(E) MUST BE
 INSTALLED AT THE FRONT OF THE BUILDING.
  
 10} THE PERSON TAKING RESPONSIBILITY FOR
 THE DESIGN MUST PRINT AND SIGN THEIR
 NAME TO SAME PER 106.3.4.2.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-02-02 Cont ID  
Sent By btrobaug Date 2006-02-02 Time 10:01 Rev Time 0.50
Received By btrobaug Date 2006-02-02 Time 07:51 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-11-17 Cont ID  
Sent By btrobaug Date 2005-11-17 Time 13:27 Rev Time 0.50
Received By btrobaug Date 2005-11-17 Time 11:54 Sent To M
Notes
2005-11-17 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE INDICATE THE LOCATION OF THE
 METER AND PANEL SHOWN ON THE RISER, ON
 THE PLAN.
  
 2} PLEASE SEE THERE ARE TWO DESIGNATIONS
 FOR THE SAME FEEDER ON THE RISER, ONE
 WITH 3 #!, AND ONE WITH 3 2/0. PLEASE
 CLARIFY.
  
 3} THERE ARE RECEPTACLES MISSING FROM
 THE BEDROOM(#2)AND THE NEW BEDROOM.
 210.52(A).
  
 3} A RECEPTACLE PER 210.52(E) MUST BE
 INSTALLED AT THE FRONT OF THE BUILDING.
  
 4} PER 210.52(D) A RECEPTACLE IN
 COMPLIANCE WITH 210.11(C)(3) MUST BE
 INSTALLED AT BOTH SINKS IN THE NEW BATH.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-01-04 Cont ID  
Sent By adarroug Date 2007-01-04 Time 16:05 Rev Time 0.00
Received By adarroug Date 2007-01-04 Time 16:05 Sent To E
Notes
2007-01-04 16:05:55TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2006-08-07 Cont ID  
Sent By adarroug Date 2006-08-07 Time 11:23 Rev Time 0.00
Received By adarroug Date 2006-08-07 Time 11:23 Sent To E
Notes
2006-08-07 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2006-07-03 Cont ID  
Sent By adarroug Date 2006-07-03 Time 13:15 Rev Time 0.00
Received By adarroug Date 2006-07-03 Time 13:15 Sent To E
Notes
2006-07-03 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2006-06-26 Cont ID  
Sent By adarroug Date 2006-06-26 Time 11:39 Rev Time 0.00
Received By adarroug Date 2006-06-26 Time 11:39 Sent To Z
Notes
2006-06-26 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-05-26 Cont ID  
Sent By adarroug Date 2006-05-26 Time 10:59 Rev Time 0.00
Received By adarroug Date 2006-05-26 Time 10:58 Sent To E
Notes
2006-05-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-05-18 Cont ID  
Sent By adarroug Date 2006-05-18 Time 09:59 Rev Time 0.00
Received By adarroug Date 2006-05-18 Time 09:59 Sent To Z
Notes
2006-05-18 00:00:00TO "Z" BOX/RESUB--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-05-05 Cont ID  
Sent By shill Date 2006-05-05 Time 15:24 Rev Time 0.00
Received By shill Date 2006-05-05 Time 15:24 Sent To PC
Notes
2006-05-05 00:00:00O/B CALLED, PLANS WRONG, REQUESTED THAT
 PLANS BE REMOVED FROM REVIEW, NO REVIEWS
 DONE.TAKEN OFF OF BT DESK AND SENT TO
 FRONT COUNTERSMH

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-05-04 Cont ID  
Sent By adarroug Date 2006-05-04 Time 11:31 Rev Time 0.00
Received By adarroug Date 2006-05-04 Time 11:31 Sent To E
Notes
2006-05-04 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-01-30 Cont ID  
Sent By adarroug Date 2006-01-30 Time 14:01 Rev Time 0.00
Received By adarroug Date 2006-01-30 Time 14:01 Sent To E
Notes
2006-01-30 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-01-20 Cont ID  
Sent By adarroug Date 2006-01-20 Time 14:07 Rev Time 0.00
Received By adarroug Date 2006-01-20 Time 14:06 Sent To Z
Notes
2006-01-20 00:00:00TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-11-09 Cont ID  
Sent By adarroug Date 2005-11-09 Time 14:47 Rev Time 0.00
Received By adarroug Date 2005-11-09 Time 14:47 Sent To E
Notes
2005-11-09 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-15 Cont ID  
Sent By alange Date 2005-12-15 Time 07:31 Rev Time 0.00
Received By alange Date 2005-10-20 Time 11:03 Sent To  
Notes
2005-10-20 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2007-02-06 Cont ID  
Sent By tgordon Date 2007-02-06 Time 16:20 Rev Time 0.30
Received By tgordon Date 2007-02-06 Time 16:20 Sent To  
Notes
2007-02-06 16:21:24MECH. REVISION TO PAGE 7-1 .

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2006-12-11 Cont ID  
Sent By hmoser Date 2006-12-11 Time 17:28 Rev Time 0.00
Received By hmoser Date 2006-12-11 Time 17:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-07-06 Cont ID  
Sent By tgordon Date 2006-07-06 Time 08:23 Rev Time 0.30
Received By tgordon Date 2006-07-06 Time 08:23 Sent To P
Notes
2006-07-06 00:00:00*** PROVISO ***
 1) CLOTHES DRYER VENT TERMINATION MUST
 BE A MIN. OF 4 FT. FROM A/C CONDENSER
 UNIT, PER 2004 FBC/M 501.2 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-05-30 Cont ID  
Sent By tgordon Date 2006-05-30 Time 11:47 Rev Time 1.00
Received By tgordon Date 2006-05-30 Time 11:47 Sent To P
Notes
2006-05-30 00:00:00*** DENIED ***
 1) PLEASE SUBMIT 2 IDENTICAL COPYS OF
 ENERGY CALCULATIONS (NOT 3 DIFFERENT
 COPYS).
  
 2) PLEASE SIGN THE 2 IDENTICAL COPYS OF
 ENERGY CALCULATIONS AT THE OWNER/AGENT
 SPACE.
  
 3) PLEASE SUBMIT 2 IDENTICAL COPYS OF
 MANUAL J CALCULATIONS ( NOT 4 DIFFERENT
 COPYS).
  
 4) PLEASE SUBMIT 2 IDENTICAL COPYS OF
 MECHANICAL PLANS THAT MATCH THE BUILDING
 FLOOR PLANS.
  
 5) PLEASE SHOW A/C EQUIPMENT LISTING ON
 MECHANICAL PLAN.
  
 6) IS THE ADDITION A 2 STORY ADDITION,
 AS THE 2ND. FLOOR MECHANICAL PLAN REFERS
 TO IT AS NEW MASTER BEDROOM.
  
 7) PLEASE MARK ALL OLD PLANS THAT ARE NO
 LONGER USED AS OLD.
  
 8)CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY. PER 2004 FBC 106.1.1
 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-02-03 Cont ID  
Sent By tgordon Date 2006-02-03 Time 10:28 Rev Time 1.00
Received By tgordon Date 2006-02-03 Time 10:28 Sent To B
Notes
2006-02-03 00:00:00 
 *** DENIED ***
 1) ENERGY COLCULATIONS NEED TO BE SIGNED
 BY OWNER/ AGENT.
  
 2) MANUAL J CALCULATIONS ARE ONLY
 SHOWING NEW ADDITION SQUARE FEET ONLY
 BUT THEENTIRE HOUSE IS BEING AIR
 CONDITIONED SO SQUARE FEET NEEDS TO BE
 FOR ENTIRE HOUSE. AND PLEASE HAVE MANUAL
 'J' SHOWING CFM'S AND DUCT SIZES TO ALL
 ROOMS.
  
 3) NEED TO PROVIDE TWO COPYS OF ALL
 PAPER-WORK.
  
 4) EQUIPMENT LIST OR MECH. PLANS IS
 CALLING FOR 10.3 SEER (ENERGY CAL'S 12
 SEER), UNIT #1 3 TON ( TOTAL BTU'S
 45,500 IS INCORRECT), UNIT #2 2 TON
 (TOTAL BTU'S 45,500 IS INCORRECT).
 PLEASE CORRECT INFORMATION ON EQUIP.
 LIST TO COINCIDE WITH NEW MANUAL 'J'.
  
 5) AHU #1, 10" SUPPLY AIR DUCT FROM AHU
 IS TO SMALL FOR A 3 TON UNIT.
  
 6) AHU #1, RETURN AIR GRILL IS NOT
 SIZED.
  
 7) NO RETURN AIR IS PROVIDED FOR BEDROOM
 #1, EXISTING BEDROOM #1 & #2 SEE NOTE#8.
  
 8) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 9) PLEASE NOTE ON MECH. PLANS IF ALL
 DUCT WORK IS NOT NEW, THEN NOTE WHAT
 DUCT WORK IS EXISTING.
  
 10)AHU #2, 12" RETURN AIR DUCT AND 14X14
 RETURN AIR GRILL ARE TO SMALL FOR A 2
 TON UNIT.
  
 11) PLEASE SEE HIGH-LIGHTS ON MECH.
 PLANS AND CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-11-17 Cont ID  
Sent By tgordon Date 2005-11-17 Time 14:11 Rev Time 0.35
Received By tgordon Date 2005-11-17 Time 14:11 Sent To P
Notes
2005-11-17 00:00:00*** DENIED ***
 1) NEED ENERGY CALCULATIONS AND MANUAL
 'J' CALCULATIONS,PER 2004 FBC
 13-600.1.ABC .
 2)GRILL SIZES AND CFM'S NOT SHOWING.
 3) PLEASE CHECK A/C EQUIP. INFO. AND
 CORRECT (SHOWING FOR TWO, 4 TON A/C
 SYSSTEMS.
 4) PLEASE CHECK AND CORRECT DUCT SIZES
 AT AHU'S.
 5)PLEASE CHECK AND CORRECT SQUARE
 FOOTAGE INFO. ON PAGE 4.1 OF PLANS.
 6) IF KITCHEN RANGE IS A DOWN DRAFT
 PLAESE SUBMIT DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS, AND SHOW EXHUST DUCT ON
 PLANS.
 7) PLEASE SHOW LOCATION OF CONDENSER
 UNITS ON PLANS.
 IF YOU HAVE ANY QUESTIONS PLEASE CALL
 TOM GORDON 805-6729 OR PATTY KRAUSS
 805-6719.

Review Stop P PLUMBING
Rev No 5 Status P Date 2007-02-05 Cont ID  
Sent By jleech Date 2007-02-05 Time 07:49 Rev Time 0.00
Received By jleech Date 2007-02-05 Time 07:49 Sent To M
Notes
2007-02-05 07:50:29REVISED RISER DIAGRAM OK

Review Stop P PLUMBING
Rev No 4 Status P Date 2006-07-08 Cont ID  
Sent By jleech Date 2006-07-08 Time 07:50 Rev Time 0.00
Received By jleech Date 2006-07-08 Time 07:50 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2006-06-10 Cont ID  
Sent By jleech Date 2006-06-10 Time 08:03 Rev Time 0.00
Received By jleech Date 2006-06-10 Time 08:03 Sent To B
Notes
2006-06-10 00:00:00DENIED;
 1.NEW AUTOMATIC CLOTHES WASHER NOT SHOWN
 ON RISER DIAGRAM.
 2.WASHING MACHINE PIPING DETAIL DIAGRAM;
 THE FIXTURE DRAIN SHALL BE 3" PER.
 FBC-2004 PLUMBING SEC. 406.3. A CLEANOUT
 SHALL BE INSTALL IN THE VENT OF W/M AT
 48" AFF.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-02-03 Cont ID  
Sent By jleech Date 2006-02-03 Time 07:20 Rev Time 0.33
Received By jleech Date 2006-02-03 Time 07:20 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-12-06 Cont ID  
Sent By jleech Date 2005-12-06 Time 17:28 Rev Time 1.00
Received By jleech Date 2005-12-06 Time 17:28 Sent To B
Notes
2005-12-06 00:00:00DENIED;
 1.PLANS WERE REVIEW WITH THE FBC-2004.
 2.SANITARY RISER DIAGRAM
 REQUIRED,AMENDMENT TO FBC CHAPTER 1
 SEC.106.3.5.4(9).
 3.HEAT TRAPS REQUIRED ON HOT AND COLD
 WATER PIPING. (WATER HEATER DIAGRAM)
 4.(W/M DETAIL)WATER HAMMER ARRESTORS
 REQUIRED. SEC. 604.9 AND THE BRANCH
 DRAIM OR DRAINAGE STACK MUST BE A
 MINIMUM OF 3" SEC.406.3
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 4 Status P Date 2006-06-30 Cont ID  
Sent By mmclean Date 2006-06-30 Time 15:12 Rev Time 0.00
Received By mmclean Date 2006-06-30 Time 15:12 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2006-05-25 Cont ID  
Sent By mmclean Date 2006-05-25 Time 13:33 Rev Time 0.00
Received By mmclean Date 2006-05-25 Time 13:33 Sent To I
Notes
2006-05-25 00:00:00DENIED,
 1. THE SURVEY PROVIDED DOES NOT SHOW AN
 EXISTING CARPORT (ONLY A CONCRETE
 DRIVEWAY), PLEASE PROVIDE TWO CURRENT
 SURVEY SHOWING THE EXISTING CARPORT.
 2. MUST PROVIDE THE SIDE SETBACK OF THE
 EXISTING CARPORT AND THE EXISTING
 COVERED ENTRY AND PROPOSED NEW ENCLOSED
 ENTRY ON THE SITEPLAN PROVIDED.(FROM
 PROPERTY LINE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 2 Status P Date 2006-01-28 Cont ID  
Sent By mmclean Date 2006-01-28 Time 11:50 Rev Time 0.00
Received By mmclean Date 2006-01-28 Time 11:50 Sent To I
Notes
2006-01-28 00:00:00NOTE: THE SHED MUST BE 6FT FROM PROPOSED
 ADDITION.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-11-07 Cont ID  
Sent By mmclean Date 2005-11-07 Time 15:59 Rev Time 0.00
Received By mmclean Date 2005-11-07 Time 15:59 Sent To I
Notes
2005-11-07 00:00:00DENIED,
 1. THE PROPOSED ADDITION TO MAIN
 STRUCTURE MUST BE 6FT FROM THE EXISTING
 SHED.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720