| Plan Review Stops For Permit 05100947 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-08-08 |
Time |
08:31 |
Rev Time |
1.66 |
| Received By |
alange |
Date |
2006-08-08 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-10 |
Time |
10:44 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-07-10 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2006-07-10 00:00:00 | DENIED | | | | | | 1.713.13(2) F.S.THE NOTICE OF | | | COMMENCEMENT MUST BE RE-RECORDED BECAUSE | | | THE DESCRIBED IMPROVEMENT OR | | | CONSTRUCTION DID NOT COMMENCE WITHIN 90 | | | DAYS OF RECORDING. | | | | | | 2.PRODUCT APPROVALS REQUIRED FOR OVER | | | HEAD DOOR. | | | | | | | | | 3.ALL PLANS SUBMITTED AFTER OCTOBER, | | | 1, 2005 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE.CORRECT CODE | | | SECTIONS USED AND CHANGE WIND DESIGN TO | | | ASCE 7-02. | | | | | | 4.A DESIGN PROFESSIONAL OR AN OWNER | | | MUST ELECT ONE OR A COMBINATION OF | | | LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | | SHOW HOW PLANS WILL COMPLY WITH THE | | | SECTION(S) SELECTED.2004 FBC EXISTING | | | BUILDING 301.5 | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET | | | OR SPECIFICATION PAGE WHERE THE CHANGES | | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | ART LANGE | | | CONSTRUCTION SERVICES DEPARTMENT | | | BUILDING PLANS EXAMINER | | | 561-805-6672 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-12 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-12 |
Time |
10:44 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2006-06-12 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2006-06-12 00:00:00 | DENIED | | | | | | 3.SIGN OWNER/AGENT ON ENERGY CALCS. | | | | | | 5.SUBMIT PRODUCT APPROVALS FOR | | | HARDIE-PLANK SIDING.INFORMATION | | | SUBMITTED IS A PRODUCT INFO GUIDE. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-07 |
Time |
09:06 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2006-02-07 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2006-02-07 00:00:00 | DENIED | | | | | | 3.SIGN OWNER/AGENT ON ENERGY CALCS. | | | | | | 5.SUBMIT PRODUCT APPROVALS FOR | | | HARDIE-PLANK SIDING.INFORMATION | | | SUBMITTED IS A PRODUCT INFO GUIDE. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-15 |
Time |
07:27 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2005-12-15 |
Time |
07:27 |
Sent To |
|
|
| Notes |
| 2005-12-15 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SUBMIT TWO ORIGONAL SIGNED AND | | | SEALED SURVEYS FS. 472.025 | | | | | | 4.SUBMIT TWO COPIES OF ENERGY CALCS. | | | | | | 5.SUBMIT PRODUCT APPROVALS FOR LINTELS | | | AND HARDIE-PLANK SIDING WITH THE | | | FOLLOWING STATE PRODUCT APPROVAL | | | ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6.ALL PLANS SUBMITTED AFTER OCTOBER 1, | | | 2005 SHALL BE DESIGNED TO THE 2004 FBC. | | | | | | ANY QUESTIONS CALL ME. | | | | | | ART LANGE | | | BUILIDNG PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-01-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-01-11 |
Time |
15:03 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-01-11 |
Time |
13:08 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-08-07 |
Time |
14:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-08-07 |
Time |
13:44 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-07-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-05 |
Time |
12:57 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-07-05 |
Time |
12:18 |
Sent To |
M |
|
| Notes |
| 2006-07-05 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} THE SERVICE ENTRANCE CONDUCTORS FOR | | | 200 AMPS MUST BE A MINIMUM OF 2/0 | | | COPPER, 310.15(B)(6). | | | | | | 2} CIRCUIT #18, #12WIRE ON A 30 AMP | | | BREAKER DOES NOT COMPLY WITH 310.16. | | | | | | 3} THE COOKTOP AND THE AHU HAVE | | | INCORRECT OCP AND WIRE SIZE FOR THE | | | RESPECTIVE LOADS. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-05-30 |
Time |
08:57 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-05-30 |
Time |
06:50 |
Sent To |
M |
|
| Notes |
| 2006-05-30 00:00:00 | | | | NONCOMLPIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE INDICATE THE LOCATION OF THE | | | PANEL SHOWN ON THE RISER, ON THE PLAN. | | | | | | 2} THE FEEDER FROM THE MAIN TO THE PANEL | | | IS INCORRECT FOR A 200 AMP SERVICE. SEE | | | 310.15(B)(6). | | | | | | 3}PER 110.9 AND 110.10: OBTAIN THE | | | AVAILABLE FAULT CURRENT AT THE UTILITY | | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | | INDICATE THE AIC RATING FOR THE | | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | | THE AVAILABLE FAULT. | | | | | | 4} THE 80 AMP OCP IS TOO LARGE FOR THE | | | CONDUCTORS FEEDONG THE AHU'S. SEE | | | 310.16. ALSO SEE CIRCUITS 2,4 IS | | | MISMARKED "A/C". | | | | | | 5} CIRCUIT #15 MARKED "FUTURE POOL PUMP" | | | SHOWS 2500 WATTS ON A 20 AMP BREAKER, | | | PLEASE CORRECT. | | | | | | 6} CIRCUIT #17 MARKED "FUTURE POOL | | | HEATER" @ 1200 WATTS SEEMS INCORRECT. | | | TYPICALLY THESE HEATERS ARE NO SMALLER | | | THAN 5000 WATTS @ 240 VOLTS. | | | | | | 7} PLEASE CORRECT CIRCUIT #9 & 11, 30AMP | | | OCP FOR 10000 WATTS. | | | | | | 8} THERE ARE RECEPTACLES MISSING FROM | | | THE BEDROOM(#2)AND THE NEW BEDROOM. | | | 210.52(A). | | | | | | 9} A RECEPTACLE PER 210.52(E) MUST BE | | | INSTALLED AT THE FRONT OF THE BUILDING. | | | | | | 10} THE PERSON TAKING RESPONSIBILITY FOR | | | THE DESIGN MUST PRINT AND SIGN THEIR | | | NAME TO SAME PER 106.3.4.2. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-02-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-02 |
Time |
10:01 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-02-02 |
Time |
07:51 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-17 |
Time |
13:27 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2005-11-17 |
Time |
11:54 |
Sent To |
M |
|
| Notes |
| 2005-11-17 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE INDICATE THE LOCATION OF THE | | | METER AND PANEL SHOWN ON THE RISER, ON | | | THE PLAN. | | | | | | 2} PLEASE SEE THERE ARE TWO DESIGNATIONS | | | FOR THE SAME FEEDER ON THE RISER, ONE | | | WITH 3 #!, AND ONE WITH 3 2/0. PLEASE | | | CLARIFY. | | | | | | 3} THERE ARE RECEPTACLES MISSING FROM | | | THE BEDROOM(#2)AND THE NEW BEDROOM. | | | 210.52(A). | | | | | | 3} A RECEPTACLE PER 210.52(E) MUST BE | | | INSTALLED AT THE FRONT OF THE BUILDING. | | | | | | 4} PER 210.52(D) A RECEPTACLE IN | | | COMPLIANCE WITH 210.11(C)(3) MUST BE | | | INSTALLED AT BOTH SINKS IN THE NEW BATH. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-04 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-04 |
Time |
16:05 |
Sent To |
E |
|
| Notes |
| 2007-01-04 16:05:55 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-07 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-07 |
Time |
11:23 |
Sent To |
E |
|
| Notes |
| 2006-08-07 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-03 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-03 |
Time |
13:15 |
Sent To |
E |
|
| Notes |
| 2006-07-03 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-26 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-26 |
Time |
11:39 |
Sent To |
Z |
|
| Notes |
| 2006-06-26 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-26 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-26 |
Time |
10:58 |
Sent To |
E |
|
| Notes |
| 2006-05-26 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-18 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-18 |
Time |
09:59 |
Sent To |
Z |
|
| Notes |
| 2006-05-18 00:00:00 | TO "Z" BOX/RESUB--NEW SHEETS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-05-05 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-05-05 |
Time |
15:24 |
Sent To |
PC |
|
| Notes |
| 2006-05-05 00:00:00 | O/B CALLED, PLANS WRONG, REQUESTED THAT | | | PLANS BE REMOVED FROM REVIEW, NO REVIEWS | | | DONE.TAKEN OFF OF BT DESK AND SENT TO | | | FRONT COUNTERSMH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-04 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-04 |
Time |
11:31 |
Sent To |
E |
|
| Notes |
| 2006-05-04 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-30 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-30 |
Time |
14:01 |
Sent To |
E |
|
| Notes |
| 2006-01-30 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-20 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-20 |
Time |
14:06 |
Sent To |
Z |
|
| Notes |
| 2006-01-20 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-09 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-09 |
Time |
14:47 |
Sent To |
E |
|
| Notes |
| 2005-11-09 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-15 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-10-20 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2005-10-20 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-02-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-06 |
Time |
16:20 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-02-06 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2007-02-06 16:21:24 | MECH. REVISION TO PAGE 7-1 . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-12-11 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-12-11 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-12-11 |
Time |
17:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-07-06 |
Time |
08:23 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-07-06 |
Time |
08:23 |
Sent To |
P |
|
| Notes |
| 2006-07-06 00:00:00 | *** PROVISO *** | | | 1) CLOTHES DRYER VENT TERMINATION MUST | | | BE A MIN. OF 4 FT. FROM A/C CONDENSER | | | UNIT, PER 2004 FBC/M 501.2 . | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-30 |
Time |
11:47 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2006-05-30 |
Time |
11:47 |
Sent To |
P |
|
| Notes |
| 2006-05-30 00:00:00 | *** DENIED *** | | | 1) PLEASE SUBMIT 2 IDENTICAL COPYS OF | | | ENERGY CALCULATIONS (NOT 3 DIFFERENT | | | COPYS). | | | | | | 2) PLEASE SIGN THE 2 IDENTICAL COPYS OF | | | ENERGY CALCULATIONS AT THE OWNER/AGENT | | | SPACE. | | | | | | 3) PLEASE SUBMIT 2 IDENTICAL COPYS OF | | | MANUAL J CALCULATIONS ( NOT 4 DIFFERENT | | | COPYS). | | | | | | 4) PLEASE SUBMIT 2 IDENTICAL COPYS OF | | | MECHANICAL PLANS THAT MATCH THE BUILDING | | | FLOOR PLANS. | | | | | | 5) PLEASE SHOW A/C EQUIPMENT LISTING ON | | | MECHANICAL PLAN. | | | | | | 6) IS THE ADDITION A 2 STORY ADDITION, | | | AS THE 2ND. FLOOR MECHANICAL PLAN REFERS | | | TO IT AS NEW MASTER BEDROOM. | | | | | | 7) PLEASE MARK ALL OLD PLANS THAT ARE NO | | | LONGER USED AS OLD. | | | | | | 8)CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY. PER 2004 FBC 106.1.1 | | | . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-03 |
Time |
10:28 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2006-02-03 |
Time |
10:28 |
Sent To |
B |
|
| Notes |
| 2006-02-03 00:00:00 | | | | *** DENIED *** | | | 1) ENERGY COLCULATIONS NEED TO BE SIGNED | | | BY OWNER/ AGENT. | | | | | | 2) MANUAL J CALCULATIONS ARE ONLY | | | SHOWING NEW ADDITION SQUARE FEET ONLY | | | BUT THEENTIRE HOUSE IS BEING AIR | | | CONDITIONED SO SQUARE FEET NEEDS TO BE | | | FOR ENTIRE HOUSE. AND PLEASE HAVE MANUAL | | | 'J' SHOWING CFM'S AND DUCT SIZES TO ALL | | | ROOMS. | | | | | | 3) NEED TO PROVIDE TWO COPYS OF ALL | | | PAPER-WORK. | | | | | | 4) EQUIPMENT LIST OR MECH. PLANS IS | | | CALLING FOR 10.3 SEER (ENERGY CAL'S 12 | | | SEER), UNIT #1 3 TON ( TOTAL BTU'S | | | 45,500 IS INCORRECT), UNIT #2 2 TON | | | (TOTAL BTU'S 45,500 IS INCORRECT). | | | PLEASE CORRECT INFORMATION ON EQUIP. | | | LIST TO COINCIDE WITH NEW MANUAL 'J'. | | | | | | 5) AHU #1, 10" SUPPLY AIR DUCT FROM AHU | | | IS TO SMALL FOR A 3 TON UNIT. | | | | | | 6) AHU #1, RETURN AIR GRILL IS NOT | | | SIZED. | | | | | | 7) NO RETURN AIR IS PROVIDED FOR BEDROOM | | | #1, EXISTING BEDROOM #1 & #2 SEE NOTE#8. | | | | | | 8) BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 9) PLEASE NOTE ON MECH. PLANS IF ALL | | | DUCT WORK IS NOT NEW, THEN NOTE WHAT | | | DUCT WORK IS EXISTING. | | | | | | 10)AHU #2, 12" RETURN AIR DUCT AND 14X14 | | | RETURN AIR GRILL ARE TO SMALL FOR A 2 | | | TON UNIT. | | | | | | 11) PLEASE SEE HIGH-LIGHTS ON MECH. | | | PLANS AND CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-17 |
Time |
14:11 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2005-11-17 |
Time |
14:11 |
Sent To |
P |
|
| Notes |
| 2005-11-17 00:00:00 | *** DENIED *** | | | 1) NEED ENERGY CALCULATIONS AND MANUAL | | | 'J' CALCULATIONS,PER 2004 FBC | | | 13-600.1.ABC . | | | 2)GRILL SIZES AND CFM'S NOT SHOWING. | | | 3) PLEASE CHECK A/C EQUIP. INFO. AND | | | CORRECT (SHOWING FOR TWO, 4 TON A/C | | | SYSSTEMS. | | | 4) PLEASE CHECK AND CORRECT DUCT SIZES | | | AT AHU'S. | | | 5)PLEASE CHECK AND CORRECT SQUARE | | | FOOTAGE INFO. ON PAGE 4.1 OF PLANS. | | | 6) IF KITCHEN RANGE IS A DOWN DRAFT | | | PLAESE SUBMIT DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS, AND SHOW EXHUST DUCT ON | | | PLANS. | | | 7) PLEASE SHOW LOCATION OF CONDENSER | | | UNITS ON PLANS. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-02-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-02-05 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-02-05 |
Time |
07:49 |
Sent To |
M |
|
| Notes |
| 2007-02-05 07:50:29 | REVISED RISER DIAGRAM OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-07-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-07-08 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-07-08 |
Time |
07:50 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-06-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-10 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-10 |
Time |
08:03 |
Sent To |
B |
|
| Notes |
| 2006-06-10 00:00:00 | DENIED; | | | 1.NEW AUTOMATIC CLOTHES WASHER NOT SHOWN | | | ON RISER DIAGRAM. | | | 2.WASHING MACHINE PIPING DETAIL DIAGRAM; | | | THE FIXTURE DRAIN SHALL BE 3" PER. | | | FBC-2004 PLUMBING SEC. 406.3. A CLEANOUT | | | SHALL BE INSTALL IN THE VENT OF W/M AT | | | 48" AFF. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-02-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-03 |
Time |
07:20 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-02-03 |
Time |
07:20 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-06 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-06 |
Time |
17:28 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-12-06 |
Time |
17:28 |
Sent To |
B |
|
| Notes |
| 2005-12-06 00:00:00 | DENIED; | | | 1.PLANS WERE REVIEW WITH THE FBC-2004. | | | 2.SANITARY RISER DIAGRAM | | | REQUIRED,AMENDMENT TO FBC CHAPTER 1 | | | SEC.106.3.5.4(9). | | | 3.HEAT TRAPS REQUIRED ON HOT AND COLD | | | WATER PIPING. (WATER HEATER DIAGRAM) | | | 4.(W/M DETAIL)WATER HAMMER ARRESTORS | | | REQUIRED. SEC. 604.9 AND THE BRANCH | | | DRAIM OR DRAINAGE STACK MUST BE A | | | MINIMUM OF 3" SEC.406.3 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-06-30 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-06-30 |
Time |
15:12 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2006-05-25 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-05-25 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-05-25 |
Time |
13:33 |
Sent To |
I |
|
| Notes |
| 2006-05-25 00:00:00 | DENIED, | | | 1. THE SURVEY PROVIDED DOES NOT SHOW AN | | | EXISTING CARPORT (ONLY A CONCRETE | | | DRIVEWAY), PLEASE PROVIDE TWO CURRENT | | | SURVEY SHOWING THE EXISTING CARPORT. | | | 2. MUST PROVIDE THE SIDE SETBACK OF THE | | | EXISTING CARPORT AND THE EXISTING | | | COVERED ENTRY AND PROPOSED NEW ENCLOSED | | | ENTRY ON THE SITEPLAN PROVIDED.(FROM | | | PROPERTY LINE. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-01-28 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-01-28 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-01-28 |
Time |
11:50 |
Sent To |
I |
|
| Notes |
| 2006-01-28 00:00:00 | NOTE: THE SHED MUST BE 6FT FROM PROPOSED | | | ADDITION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-07 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-11-07 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-11-07 |
Time |
15:59 |
Sent To |
I |
|
| Notes |
| 2005-11-07 00:00:00 | DENIED, | | | 1. THE PROPOSED ADDITION TO MAIN | | | STRUCTURE MUST BE 6FT FROM THE EXISTING | | | SHED. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|