| Plan Review Stops For Permit 05100943 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-08 |
Time |
11:30 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-02-07 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-01-03 |
Time |
11:22 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-01-03 |
Time |
10:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-02 |
Time |
13:47 |
Rev Time |
1.00 |
| Received By |
alange |
Date |
2005-12-02 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2005-12-02 00:00:00 | DENIED | | | | | | 1.PLANS SUBMITED AFTER OCTOBER 1, 2005 | | | SHALL BE DESIGNED TO THE 2004 FBC. | | | | | | 2.FBC 2004 EXISTING BUILDING 301.5 | | | A DESIGN PROFESSIONAL OR AN OWNER MUST | | | ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PERSUANT TO SECTIONS 303, | | | 304, 305 OF THIS CODE.SHOW HOW | | | ALTERATION WILL BE DESIGNED TO LEVEL | | | SELECTED. | | | | | | 3.CHECK DETAILS WHEN DESIGNING TO THE | | | 2004 FBC. FOR EXAMPLE, THE IS NO TYPE 6 | | | CONSTRUCTION, CODE SECTIONS SITED WILL | | | BE CHANGED. | | | **CHECK PLANS SEVERAL DESIGN AND CODE | | | SECTIONS STILL REFERENCE THE 2001 FBC. | | | | | | A. ENERGY EFFIENCY FORM SHOULD BE FORM | | | 400D-04.BE SURE TO ALSO SIGN OWNER | | | AGENT ON FORM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-16 |
Time |
07:47 |
Rev Time |
2.25 |
| Received By |
alange |
Date |
2005-11-16 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2005-11-16 00:00:00 | DENIED | | | | | | 1.PLANS SUBMITED AFTER OCTOBER 1, 2005 | | | SHALL BE DESIGNED TO THE 2004 FBC. | | | | | | 2.FBC 2004 EXISTING BUILDING 301.5 | | | A DESIGN PROFESSIONAL OR AN OWNER MUST | | | ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PERSUANT TO SECTIONS 303, | | | 304, 305 OF THIS CODE.SHOW HOW | | | ALTERATION WILL BE DESIGNED TO LEVEL | | | SELECTED. | | | | | | 3.CHECK DETAILS WHEN DESIGNING TO THE | | | 2004 FBC. FOR EXAMPLE, THE IS NO TYPE 6 | | | CONSTRUCTION, CODE SECTIONS SITED WILL | | | BE CHANGED. | | | | | | 4.CLEARLY SHOW EXISTING AREAS AND | | | WALLS ALONG WITH ANY NEW WALLS AND | | | DETAILS FOR THEM. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2006-02-07 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2006-02-07 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-03 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-03 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | ******* PROVISO/ REVISON NEEDED ******* | | | | | | | | | | | | 1)NOTE: PLEASE SEE 210.62, 220.12 FIR | | | MIN SHOW WINDOW RECEPTS REQUIRED FOR | | | RETAIL/MERCHANTILE OCCUPANCY. | | | PLEASE REVISE WITH ANY OTHER REVISIONS | | | BEFORE ROUGH ELECTRICAL INSPECTION. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELCTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-12-07 |
Time |
06:44 |
Rev Time |
0.30 |
| Received By |
jleahy |
Date |
2005-12-07 |
Time |
06:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-11-10 |
Time |
20:49 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-11-10 |
Time |
20:49 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | NO LOW VOLTAGE SYSTEMS SHOWN ON | | | DRAWINGS, SEPARATE PERMIT(S) REQUIRED |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-12-23 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-12-23 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2005-12-23 00:00:00 | 1. ON SHEET A.1. IT INDICATES THAT AN | | | EXISTING FIRE SPRINKLER HEAD IS TO BE | | | RELOCATED WITH A PERMIT. A PERMIT WILL | | | NOT BE REQUIRED FOR A SINGLE FIRE | | | SPRINKLER HEAD RELOCATION. A LICENSED | | | FIRE SPRINKLER CONTRACTOR MUST BE USED. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER | | | 804-4709 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-12-14 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-12-14 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-15 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-15 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | ******DENIED****** | | | | | | 1) NO EXIT SIGNS OR EMERGENCY LIGHTING | | | SHOWN ON PLANS. NEW OR EXISTING? | | | | | | 2) PLANS INDICATE THAT THE BUILDING IS | | | FIRE SPRINKLERED. SEPRATE SHOP DRAWINGS | | | AND PERMIT ARE REQUIRED FOR FIRE | | | SPRINKLER REMODEL. | | | | | | | | | MIKE WENNERGREN, CAPTAI/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-24 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-24 |
Time |
14:41 |
Sent To |
M |
|
| Notes |
| 2006-03-24 00:00:00 | TO MECH INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-07 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-07 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2006-02-07 00:00:00 | TO "BOB"#5 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-19 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-19 |
Time |
11:29 |
Sent To |
B |
|
| Notes |
| 2006-01-19 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-23 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-23 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2005-12-23 00:00:00 | TO "BOB#1 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-01 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-01 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2005-12-01 00:00:00 | TO "BOB"#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-11-16 |
Time |
07:47 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-10-20 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2005-10-20 00:00:00 | TO "BOB"#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-24 |
Time |
15:59 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-03-24 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2006-03-24 00:00:00 | REV. TO MECH. PLANS . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-10 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-02-10 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-02-10 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-29 |
Time |
12:15 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-12-29 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2005-12-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-09 |
Time |
08:11 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2005-12-09 |
Time |
08:10 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-11-15 |
Time |
10:45 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-11-15 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2005-11-15 00:00:00 | MECH. PLAN REVIEW: | | | | | | PROVISO: PROVIDE FOR AUTO. FAN SHUT | | | DOWN BY DUCT SMOKE DETECTOR. | | | | | | 2004 FBC/M 606.2.1. | | | | | | PAT RAFTER 561/6728 OR 6719 PATTY | | | KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2006-02-16 |
Time |
10:01 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2006-02-16 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2006-02-16 00:00:00 | REVISION:"3" IN CLOUDS, BATHROOM WITH | | | AIR ADMITTANCE VALVES AND TANKLESS WATER | | | HEATER | | | | | | PASSED PER PHONE CONVERSATION WITH JOHN | | | LEECH |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-08 |
Time |
17:15 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2006-02-08 |
Time |
17:15 |
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | REVISION DENIED; | | | 1.SHOW THE 3 MECHANICAL VENTS TO BE | | | USED. | | | 2.MOP SINK REQUIRES HOT WATER. SEE | | | FBC-2004 PLUMBING SEC.607.1 MOP SINK IS | | | FOR BUILDING MAINTENANCE. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-03 |
Time |
09:43 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2006-01-03 |
Time |
09:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-12-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-12 |
Time |
08:38 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-12 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2005-12-12 00:00:00 | DENIED; | | | 1.DRINKING FOUNTAIN REQUIRED NOT BOTTLE | | | WATER FBC-2004 PLUMBING SEC. 410.1. | | | 2.PAGE LS.1 DETAIL 4, HIGHT OF TOILET | | | SEAT TO BE 17 - 19" SEE FBC-2004 CHAPTER | | | 11, SEC 11-4.16.3. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-11-16 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-11-16 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2005-11-16 00:00:00 | PAUL SCHMITZ | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | DENIED | | | 1) THIS PLAN ISREVIEWED UNDER 2004 | | | FLORIDA BUILDING CODE. | | | NOTES ON PLANS SHOULD REFELECT THE SAME. | | | | | | 2)SEC 403 MINIMUM PLUMBING FACILITIES | | | TABLE 403.1 BUSINESS OUCPANCY | | | ONE DRINKING FOUNTAIN REQUIRED. | | | 3)SHT LS.1 DETAIL "3" WATER CLOSET IS | | | REQUIRED TO BE 1'6" OFF THE WALL | | | 4)SHT M.1 PLUMBING NOTES # 10 AIR | | | CHAMBER. | | | SEC 604.9 WATER HAMMER | | | WATER HAMMER ARRESTORS SHALL CONFORM TO | | | ASSE 1010 | | | 5) SHT M.1 WATER ISOMETRIC | | | WATER PIPE SIZE TO COMPLY WITH | | | TABLE 604.3 | | | END OF COMMENTS QUESTIONS 561-805-6692 | | | | | | |
|
|