| Plan Review Stops For Permit 05100637 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2006-02-08 00:00:00 | OK, ADDRESS WAS CORRECTED IN SYSTEM. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-23 |
|
|
Cont ID |
|
| Sent By |
ptjomsto |
Date |
2006-01-23 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
ptjomsto |
Date |
2006-01-23 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2006-01-23 00:00:00 | ADDRESS ON APP READS 2130 | | | CENTREPARK/PAPA ALSO/CP READS 2100 | | | CENTREPARK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-11-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-11-15 |
Time |
10:39 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-11-15 |
Time |
10:39 |
Sent To |
PC |
|
| Notes |
| 2006-11-15 10:40:08 | REVISIONS A201,A202& A210 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-10-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-10-12 |
Time |
13:39 |
Rev Time |
0.66 |
| Received By |
jwitmer |
Date |
2006-10-12 |
Time |
13:39 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-09-29 |
Time |
08:11 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-09-29 |
Time |
08:10 |
Sent To |
PC |
|
| Notes |
| 2006-09-29 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05100637 | | | ADD: 2130 CENTREPARK DR | | | CONT: TURNER CONSTRUCTION | | | TEL: (786)229-4036 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISION REVIEW | | | ACTION: DENIED | | | | | | 1) ARCHITECTURAL PLANS INDICATE IN THE | | | TITLEBLOCK A FICTIUOS NAME INTERARCH | | | PLEASE PROVIDE THE FIRMS CERTIFICATE OF | | | AUTHORIZATIONNUMBER. | | | 481.219 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ARCHITECT | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ARCHITECTURAL SERVICES, SHALL INCLUDE | | | THE CERTIFICATE OF AUTHORIZATION | | | NUMBER.ADD THE NUMBER TO EACH SHEET. | | | THIS MAY BE ADDED BY HAND. | | | IF THE FIRM DOESN'T HAVE THE | | | CERTIFICATE OF AUTHORIZATION, THIS | | | FICTIOUS NAME IS TO BE RMOVED. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-15 |
Time |
15:21 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-06-15 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2006-06-15 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05100637 | | | ADD: 2100 CENTREPARK WEST | | | CONT:PLAN REVIEW | | | TO BE DETERMINED | | | TEL: ()###-#### | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | ADMINISTRATIVE CODE | | | | | | 3RD REVIEW | | | ACTION: PROVISO | | | FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT BEFORE A | | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | | WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-03-02 |
Time |
07:44 |
Rev Time |
0.66 |
| Received By |
jwitmer |
Date |
2006-03-02 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2006-03-02 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05100637 | | | ADD: 2100 CENTREPARK WEST | | | CONT:PLAN REVIEW | | | TO BE DETERMINED | | | TEL: ()###-#### | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | ADMINISTRATIVE CODE | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2) COMMENT# 6 FROM THE PREVIOUS | | | REVIEW,A-910 PLANS INDICATE DROPPED | | | CEINGS OR SOFFITS WITH THE USE OF | | | FRAMING HUNG FROM THE STRUCTURE ABOVE. | | | PROVIDE WHAT TYPE OF MATERIAL THIS IS | | | AND HOW OFTEN THE FRAMING IS TO BE | | | ATTACHED, TO THE DECK ABOVE. | | | | | | *****COMMENT UNDERCONSIDERATION******* | | | 8) RESTROOMS:1210.2 WALLS. | | | WALLS WITHIN 2 FEET (610 MM) OF URINALS | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT | | | OF 4 FEET (1219 MM) ABOVE THE FLOOR, AND | | | EXCEPT FOR STRUCTURAL ELEMENTS, THE | | | MATERIALS USED IN SUCH WALLS SHALL BE OF | | | A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE. | | | | | | 9)PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | (RAISED)TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | PLANS STILL HAVE SHEETS THAT ARE NOT | | | RAISED SEAL BUT EMBOSSED. | | | 2ND ISSUE INTERARCH DOES NOT HAVE | | | ANY ARCHITECTURAL NOR INTERIOR DESIGN | | | CERTIFICATE OF AUTHORIZATION NUMBER | | | LISTED ON THEIR HEADER SHEET. IF THEY DO | | | HAVE A CERTIFICATE OF AUTHORIZATION THE | | | ADDRESS LISTED WITH STATE TO BE THE ONE | | | USED IN FL. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-12-23 |
Time |
11:34 |
Rev Time |
3.30 |
| Received By |
jwitmer |
Date |
2005-12-23 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2005-12-23 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05100637 | | | ADD: 2100 CENTREPARK WEST | | | CONT:PLAN REVIEW | | | TO BE DETERMINED | | | TEL: ()###-#### | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | ADMINISTRATIVE CODE | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | | | | 2)110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OF THE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601.ALSO HEIGHT | | | OF BUILDING. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | | | | 3) PROVIDE INTERIOR WALL & CEILING | | | FINISH REQUIEMENTS BY OCCUPANCY:803.5 | | | INTERIOR FINISH REQUIREMENTS BASED ON | | | GROUP. | | | INTERIOR WALL AND CEILING FINISH SHALL | | | HAVE A FLAME SPREAD INDEX NOT GREATER | | | THAN THAT SPECIFIED IN TABLE 803.5 FOR | | | THE GROUP AND LOCATION DESIGNATED. | | | INTERIOR WALL AND CEILING FINISH | | | MATERIALS, OTHER THAN TEXTILES, TESTED | | | IN ACCORDANCE WITH NFPA 286 AND MEETING | | | THE ACCEPTANCE CRITERIA OF SECTION | | | 803.2.1 , SHALL BE PERMITTED TO BE USED | | | WHERE A CLASS A CLASSIFICATION IN | | | ACCORDANCE WITH ASTM E 84 IS REQUIRED. | | | | | | 4) (2004 FBC) 106.1.1 INFORMATION ON | | | CONSTRUCTION DOCUMENTS. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE & | | | EXTENT OF THE WORK PROPOSED & SHOW IN | | | DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND REVELENT | | | LAWS, ORDINANCES, AND RULES AND | | | REGULATIONS AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | SHEET A201 INDICATES A STAIR TOWER | | | HEIGHT OF BUILDING UNKOWN, THE STAIR | | | TOWER IS UNIDENTIFIABLE EXCEPT FOR DOOR# | | | 123. IN THIS STAIR TOWER THERE IS A | | | OPENING BLOCKED BUT NO DETAIL GIVING THE | | | | | | UL LISTING AND FIRE RESISTANCE RATING. | | | | | | 5) A202 INDICATES DOOR# 119 MISSING 18" | | | LATCH SIDE OF DOOR,SEE,11-4.13.6 | | | MANEUVERING CLEARENCES AT DOORS. MINIMUM | | | MANEUVERING CLEARENCES AT DOORS THAT ARE | | | NOT AUTOMATIC OR POWER-ASSISTED SHALL BE | | | AS SHOWN IN FIG. 25. THE FLOOR OR GROUND | | | AREA WITH IN THE REQUIRED CLEARENCES | | | SHALL BE CLEAR & LEVEL. | | | | | | 6)-910 PLANS INDICATE DROPPED CEINGS OR | | | SOFFITS WITH THE USE OF FRAMING HUNG | | | FROM THE STRUCTURE ABOVE. PROVIDE WHAT | | | TYPE OF MATERIAL THIS IS AND HOW OFTEN | | | THE FRAMING IS TO BE ATTACHED, AND BY | | | WHAT METHOD. | | | | | | 7) A963 INDICATES (2) KITCHEN UNITS BUT | | | NO INFORMATION AS TO: | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL | | | BE MOUNTED WITH THE COUNTER NO HIGHER | | | THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARENCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | 8) RESTROOMS:1210.2 WALLS. | | | WALLS WITHIN 2 FEET (610 MM) OF URINALS | | | AND WATER CLOSETS SHALL HAVE A SMOOTH, | | | HARD, NONABSORBENT SURFACE, TO A HEIGHT | | | OF 4 FEET (1219 MM) ABOVE THE FLOOR, AND | | | EXCEPT FOR STRUCTURAL ELEMENTS, THE | | | MATERIALS USED IN SUCH WALLS SHALL BE OF | | | A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | | MOISTURE. | | | | | | 9)PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | (RAISED)TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-12-22 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-12-22 |
Time |
10:42 |
Sent To |
PC |
|
| Notes |
| 2006-12-18 20:09:21 | ROUTED TO BILL TROBAUGH'S DESK AS HE IS THE PREVIOUS | | | REVIEWER FOR ISSUANCE OF PROJECT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-11-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-11-21 |
Time |
11:45 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-11-20 |
Time |
12:15 |
Sent To |
PC |
|
| Notes |
| 2006-11-20 12:16:31 | ROUTED TO BILL TROBAUGH AS HE WAS THE PREVIOUS | | | REVIEWER. DVPALMER. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-07-12 |
Time |
09:25 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2006-07-12 |
Time |
07:34 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-09 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-09 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2006-06-09 00:00:00 | ****UNSAT **** | | | | | | ** PLEASE KNOW, ANY WORK DONE UNDER | | | EARLY WORK RELEASE WAS AT CONTRACTORS | | | RISK AND ANY CHANGES WILL BE THE | | | RESPONSIBILTY OF THE CONTRACTORS ETC. | | | PLEASE SEE NOTES BELOW AS COMMENTS WITH | | | RESPECT THE 2004 FBC CHAPTER 13. | | | | | | PLEASE SEE THE OLD PLANS SUBMITTED BACK | | | FOR REFERENCE FOR THIS PROJECT WERE FROM | | | THE 1661 WORTHINGTON SITE AND OLD PLANS | | | CAN NOT BE VERIFIED AT THIS TIME. | | | | | | 1) NOTE: PLEASE SEE REQUIREMENTS FOR FBC | | | CHAPTER 13 ARE REQUIRED TO BE MET FOR | | | ALL LIGHTING. | | | 13-415.1.ABC.1.1, 13-415.1.ABC.1.2 ETC | | | PLEASE CLARIFY AS SOME OF THIS IS BEING | | | SHOWN, BUT UNCLEAR AS MANY LIGHTING | | | CIRCUITS DO NOT INDICATE ANY CONTROL? | | | PLEASE ALSO SEE THE OVER RIDE SWITCHES | | | MUST STATE A MAXIMUM OF 4HRS AND A MAX | | | OF 30 MINS FOR MOTION SENSORS. | | | PLEASE SEE THE OVER RIDING SWITCHES | | | SHALL BE LOCATED IN THE AREAS FO | | | LIGHTING WHICH CAN BE SEEN BY THE | | | OCCUPANT. | | | PLEASE SHOW LOCATIONS OF ALL OVER RIDES | | | AND OCC SENSORS. | | | ** PLEASE SEE A WORST CASE SCENARIO | | | SHALL BE SHOWN FOR VOLTAGE DROP PER 13-413.1.ABC.1 | | | **PLEASE ALSO SEE 13-415.1.ABC.1.3 FOR | | | OTHER LIGHTING IN AREAS. | | | ** PLEASE SEE CALCS FOR 13-415.1.AB.1 | | | | | | 2) NOTE: PLEASE SEE RISER SEEMS TO SHOW | | | NEW FEEDERS FROM GUTTER TO METER ON THE | | | EXISTING RISER AND THE NEW RISER SEEMS | | | TO INDICATE EXISTING FEEDERS ?? | | | SEEMS TO BE A MISPRINT? | | | 215.5 | | | | | | 3) NOTE: PLEASE CLARIFY IT ROOM AND | | | PLEASE SEE PART WALLS THAT DO NOT SEEM | | | TO INDICATE THE 1 HR RATING ALL THE WAY | | | AROUND? THIS SHOULD BE IN BUILDING | | | REVIEW COMMENTS ALSO. | | | PLEASE SEE NEC 645 FOR MEANS OF | | | DISCONNECTS AND DETECTION SYSTEMS WHICH | | | NEED TO BE SHOWN FOR THE IT ROOM. | | | PLEASE INDICATE THE SHUT OFF DEVICE AND | | | SHUT OFF FOR AHU. | | | PLEASE INDICATE ANY RAISED FLR AND SD'S | | | ABOVE AND BELOW. | | | PLEASE SEE NFPA-75 , CHAPTER 6 ETC. | | | | | | 4) NOTE: PLEASE CLARIFY EXISTING | | | TRANSFORMER ON RISER AND THE LOCATION OF | | | THIS TRANSFORMER. IT IS IN THE MAIN | | | ELECTRICAL ROOM ? AS PLANS DO NOT SHOW. | | | PLEASE SEE 450.13B, 450.21 | | | IF IN THE MAIN ELECTRICAL ROOM THIS | | | SHOULD BE OK. | | | | | | 5) NOTE: PLEASE SUBMIT THE SPECS ON THE | | | WATT STOPPER EQUIPMENT WHICH WILL BE | | | INSTALLED. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRCAIL PLAN REVIEW. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
20:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-08 |
Time |
19:54 |
Sent To |
I |
|
| Notes |
| 2006-02-08 00:00:00 | ********* UNSAT 2ND REVIEW ******** | | | | | | | | | COMMERACE BANK: SUBMITTED FOR PERMIT ON | | | JAN 23,2006 | | | | | | 1)NOTE: PLEASE SEE SOME NOTES FROM | | | PREVIOUS REVIEW WHICH STILL NEED TO BE | | | ADDRESSED. PLEASE SEE NOTES BELOW WHICH | | | WERE TAKEN DIRECTLY FROM PREVIOUS REVIEW | | | AND NEW NOTE FOR REPEAT COMMENTS. | | | | | | ** PLEASE SEE NO FORMAL RESPONSE WAS | | | GENERATED FROM THE DESIGNER OR ONE | | | SUBMITTED. | | | | | | ******** UNSAT ******** | | | | | | | | | | | | 1)NOTE: OK. | | | | | | 2)NOTE: OK. | | | | | | 3)NOTE: PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE (FAC) 61G1-16.004 | | | WHICH REQUIRES THE PRINTED FIRM LICENSE | | | NUMBER ON SAID TITLE BLOCK FOR | | | ARCHITECTUAL FIRM NAME. | | | PLEASE SEE FS 481.219 WHICH REQUIRES A | | | "CERTIFICATE OF AUTHORIZATION"/ FIRM # | | | NUMBER FOR SAID ARCHITECTUAL COMPANY. | | | PLEASE SEE THE ABOVE TWO COMMENTS IS | | | REQUIRED OF ALL SHEETS AND FOR ALL TRADE | | | SHEETS WHETHER OR NOT COMMENTS ARE MADE | | | BY OTHER REVIEWER(S). | | | THIS COMMENT IS NOT FOR ENGINEERING | | | FIRM, HOWEVER DOES AFFECT PM&E SHEETS. | | | | | | 4)NOTE: OK | | | | | | 5)NOTE:PLEASE VERIFY ALL EMERGENCY AND | | | EXT LTS, AS THESE COULD NOT BE LOCATED | | | ON PLANS TO MATCH UP WITH THE FIXTURE | | | SCHEDULE AND SHOWING THESE AS CONTAINING | | | THE MIN BATTERY BACK UP. | | | NEW , EXISTING? | | | PLEASE SEE NFPA-101 7.8 AND 7.9. | | | | | | 6)NOTE: OK. | | | | | | | | | 7)NOTE: PLEASE VERIFY TAPPED CONDUCOTRS | | | FROM MAIN GUTTER. PLEASE SEE 3/0'S ARE | | | RATED AT 200A'S ONLY AND OCP FOR SERVICE | | | IS SHOWN AT 210A'S. | | | 240.4,310.16 | | | PLEASE ALSO SEE 240.21 FOR "TAPPED" | | | CONDUCTORS AND MIN SIZES. PLEASE SEE | | | CONDUCTORS ARE TAPPED IN GUTTER AND THEN | | | AGAIN IN METER, WHERE AS THE 3/0'S | | | CONTINUE THROUGH, BUT #2'S ARE TAPPED | | | FROM THOSE EXISITNG TAPS? | | | PLEASE VERIFY LENGTH. | | | ALL THIS IS SHOWN AS EXISTING, HOWEVER, | | | PLEAS KNOW DUE TO THE EXTENT OF WORK AND | | | POSSIBILITY OF NON-CODE COMPLIANCE, THE | | | ABOVE WOULD NEED TO BE CORRECTED AT THIS | | | TIME. | | | | | | *** NEW NOTES*** | | | | | | 1)NOTE: PLEASE SEE NOTE #5, NO FIXTURE | | | LEGEND WAS SUBMITTED. | | | | | | 2)NOTE: PLEASE SEE PLANS WHICH WERE | | | REDLIEND ON PREVIOUS REVIEW FOR 210.8B3 | | | FOR KITCHENS IN OTHER THAN DWELLING | | | UNITS FOR REQUIRED GFI PROTECTION. | | | | | | 3)NOTE: PLEASE SEE FLORIDA STATUES | | | 553.80(2)(B) WITH RESPECT TO THE DESIGN | | | PROFESSIONAL AND REPEAT COMMENTS THREE | | | OR MORE TIMES. | | | ** PLEASE KNOW, THIS IS ONLY A NOTICE | | | GIVEN AT THIS TIME AND DOES NOT APPLY | | | FOR THIS REVIEW. | | | | | | | | | ** PLEASE BE SURE TO SEE ANY POSSIBLE | | | COMMENT(S) FROM OTHER REVIEWER(S) WHICH | | | MAY AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE TO REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | ONE COPY OF ANY OLD/VOIDED SHEETS SHOULD | | | BE SUBMNITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-22 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-22 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | ******** UNSAT ******** | | | | | | COMMERACE BANK TENAT REMODEL | | | "PLAN REVIEW ONLY" | | | | | | 1)NOTE: PELASE SEE PLANS HAVE ONLY BEEN | | | SUBMITTED FOR "PLAN REVIEW" AND HAVE NOT | | | BEEN SUBMITTED FOR PERMIT. | | | | | | 2)NOTE: PLEASE SEE FS 481.221, FAC | | | 61G1-16.003 WHICH REQUIRES THE SEALING | | | OF PLANS TO BE DONE WITH AN "IMPRESSION | | | TYPE" "RAISED" SEAL. | | | PLEASE SEE "A" SHEETS CONTAIN A "RUBBER | | | STAMP" FOR THE ARCHITECT'S SEAL. | | | | | | 3)NOTE: PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE (FAC) 61G1-16.004 | | | WHICH REQUIRES THE PRINTED FIRM LICENSE | | | NUMBER ON SAID TITLE BLOCK FOR | | | ARCHITECTUAL FIRM NAME. | | | PLEASE SEE FS 481.219 WHICH REQUIRES A | | | "CERTIFICATE OF AUTHORIZATION"/ FIRM # | | | NUMBER FOR SAID ARCHITECTUAL COMPANY. | | | PLEASE SEE THE ABOVE TWO COMMENTS IS | | | REQUIRED OF ALL SHEETS AND FOR ALL TRADE | | | SHEETS WHETHER OR NOT COMMENTS ARE MADE | | | BY OTHER REVIEWER(S). | | | THIS COMMENT IS NOT FOR ENGINEERING | | | FIRM, HOWEVER DOES AFFECT PM&E SHEETS. | | | | | | 4)NOTE: PLEASE SEE PLANS SHOW AN ADDRESS | | | OF 2130 CENTREPARK, HOWEVER WHEN APPLIED | | | FOR "PLAN REVIEW" , THE PARCEL CONTROL | | | NUMBER (PCN) USED ON APPLICATION MATCHES | | | UP TO AN ADDRESS OF 2100 CENTREPARK , | | | PLEASE VERIFY AND ADJUST EITHER AS | | | NEEDED. | | | | | | 5)NOTE: PLEASE VERIFY ALL EMERGENCY AND | | | EXT LTS, AS THESE COULD NOT BE LOCATED | | | ON PLANS TO MATCH UP WITH THE FIXTURE | | | SCHEDULE AND SHOWING THESE AS CONTAINING | | | THE MIN BATTERY BACK UP. | | | NEW , EXISTING? | | | PLEASE SEE NFPA-101 7.8 AND 7.9. | | | | | | 6)NOTE: PLEASE SEE "A" SHEETS REFERENCE | | | A 2004 NEC. | | | PLEASE SEE AS OF JULY 1ST , 2003 THE | | | STATE ADOPTED THE 2002 NEC. WE ARE | | | CURRENTLY UNDER THAT CODE. | | | PLEASE ALSO KNOW THE NEXT CODE THAT WILL | | | | | | COME INTO AFFECT FOR FUTURE KNOWLEDGE | | | WILL BE THE 2005. | | | | | | 7)NOTE: PLEASE VERIFY TAPPED CONDUCOTRS | | | FROM MAIN GUTTER. PLEASE SEE 3/0'S ARE | | | RATED AT 200A'S ONLY AND OCP FOR SERVICE | | | IS SHOWN AT 210A'S. | | | 240.4,310.16 | | | PLEASE ALSO SEE 240.21 FOR "TAPPED" | | | CONDUCTORS AND MIN SIZES. PLEASE SEE | | | CONDUCTORS ARE TAPPED IN GUTTER AND THEN | | | FAIN IN METER, WHERE AS THE 3/0'S | | | OCNTINUE THROUGH, BUT #2'S ARE TAPPED | | | FROM THOSE EXISITNG TAPS? | | | PLEASE VERIFY LENGTH. | | | ALL THIS IS SHOWN AS EXISTING, HOWEVER, | | | PLEAS KNOW DUE TO THE EXTENT OF WORK AND | | | POSSIBILITY OF NON-CODE COMPLIANCE, THE | | | ABOVE WOULD NEED TO BE CORRECTED AT THIS | | | TIME. | | | | | | ** PLEASE BE SURE TO SEE ANY POSSIBLE | | | COMMENT(S) FROM OTHER REVIEWER(S) WHICH | | | MAY AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE TO REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO COMPLETE SETS FOR | | | REVIEW AND STAMPING. | | | ONE COPY OF ANY OLD/VOIDED SHEETS SHOULD | | | BE SUBMNITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-22 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-22 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2006-06-22 00:00:00 | ***APPROVED*** | | | | | | SEPARATE SHOP DRAWINGS AND PERMITS ARE | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM REMODEL PRIOR TO ANY WORK BEING | | | DONE ON SYSTEMS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-03 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-03 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-11-23 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-11-23 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-11-23 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2005-11-23 00:00:00 | PLAN REVIEW ONLY | | | | | | 1) DEMOLITION, RENOVATION, AND | | | CONSTRUCTION SHALL COMPLY WITH NFPA 241. | | | | | | 2) THERE APPEARS TO BE NO FIRE SPRINKLER | | | PROTECTION IN TELLER CASH ROOM 109. | | | | | | 3) THE CITY OF WEST PALM BEACH FIRE | | | MARSHAL OFFICE REQUIRES HVAC DUCT SMOKE | | | DETECTORS TO ACTIVATE A GENERAL FIRE | | | ALARM. | | | | | | 4) THE FIRE ALARM SYSTEM IS REQUIRED TO | | | BE CLASS A OR FULLY ADDRESSABLE. | | | | | | 5) SEPARATE PERMIT APPLICATIONS AND SHOP | | | DRAWINGS ARE REQUIRED FOR THE FIRE ALARM | | | AND FIRE SPRINKLER SYSTEM REMODEL. | | | | | | 6) THE INTERIOR WALLS AND CEILINGS | | | FINISH MATERIAL COMPLYING WITH SECTION | | | 10.2 SHALL BE CLASS A OR CLASS B, IN | | | EXITS AND IN EXIT ACCESS CORRIDORS. IN | | | ALL OTHER AREAS, INTERIOR WALL AND | | | CEILING FINISHES SHALL BE CLASS A, CLASS | | | B, OR CLASS C. | | | | | | 7) RENOVATION SHALL COMPLY WITH NFPA 101 | | | LIFE SAFETY CODE, 2003 EDITION. | | | | | | | | | NATE MCCRAY, ASSISTANT FIRE MARSHAL | | | 561-804-4754 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-12-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-12-15 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-12-15 |
Time |
16:04 |
Sent To |
E |
|
| Notes |
| 2006-12-15 16:04:40 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-14 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-14 |
Time |
16:33 |
Sent To |
E |
|
| Notes |
| 2006-11-14 16:33:45 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-23 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-23 |
Time |
13:45 |
Sent To |
B |
|
| Notes |
| 2006-10-23 13:45:46 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-10 |
Time |
18:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-10 |
Time |
18:08 |
Sent To |
B |
|
| Notes |
| 2006-10-10 18:08:28 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-12 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-12 |
Time |
08:35 |
Sent To |
B |
|
| Notes |
| 2006-09-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-16 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-16 |
Time |
10:51 |
Sent To |
M |
|
| Notes |
| 2006-08-16 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-07-11 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-07-11 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2006-07-11 00:00:00 | TO BT DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-12 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-12 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2006-06-06 00:00:00 | TO "COMM' BD#6/1 ROLL ON RACK | | 2006-05-12 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-26 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-26 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2006-02-22 00:00:00 | TO "COMM" BD#57 | | 2006-01-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-09 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-01-09 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-14 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | TO "COMM" BD#19 | | 2005-10-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2006-11-14 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-11-14 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-11-14 |
Time |
09:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-17 |
Time |
08:26 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-08-17 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2006-08-17 00:00:00 | REVISION TO MECHANICAL PLANS PAGE M1.01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-07-12 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-12 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-12 |
Time |
10:24 |
Sent To |
B |
|
| Notes |
| 2006-07-12 00:00:00 | PROVISO ADDRESSED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2006-07-03 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-07-03 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-07-03 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2006-07-03 00:00:00 | PROVISO: | | | PLAN SHEET M1.01 ROOM 112 DUCT | | | PENETRATION SHALL HAVE A FIRE DAMPER OR | | | COMPLY WITH THE EXCEPTIONS UNDER | | | 607.5.3. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-02-27 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-02-27 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2006-02-27 00:00:00 | PLEASE NOTE, PLAN SHEET M2.01 ON THE | | | EXHAUST FAN SCHEDULE, FAN EF-1 IS NOT | | | INDICATED ON THE PLAN. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-22 |
Time |
11:05 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2005-12-22 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | *** FAILED *** | | | 1) PLEASE MAKE NOTE, MATERIALS | | | EXPOSED WITHIN PLENUMS SHALL BE NON - | | | COMBUSTIBLE OR SHALL HAVE A FLAME SPREAD | | | INDEX OF NOT MORE THAN 25 AND SMOKE - | | | DEVELOPED INDEX OF NOT MORE THAN 50 WHEN | | | TESTED IN ACCORDANCE WITH ASTM E 84. | | | | | | 2) BATHROOM EXHAUST FANS ARE SHOWING AS | | | EF-2 THERE IS NO EF-2 LISTED ON EXHAUST | | | FAN DATA. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-07-01 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-07-01 |
Time |
07:58 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-07-01 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2006-07-01 00:00:00 | RE-SUB |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-03-18 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-03-18 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-18 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2006-03-18 00:00:00 | PAUL SCHMITZ | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC2004 FUEL GAS CODEPLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | | | DENIED | | | 1) SHT 963 BREAK RM SINK RM #114 | | | DOORS NOT APPROVED ON SINK BASE. | | | | | | ?11-4.24.3 KNEE CLEARANCE. KNEE | | | CLEARANCE THAT IS AT LEAST 27 IN. (685 | | | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 | | | IN (485 MM) DEEP SHALL BE | | | PROVIDED UNDERNEATH SINKS. | | | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A | | | MAXIMUM OF 6-1/2 IN (165 MM) | | | DEEP. | | | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE AT LEAST 30 IN. BY 48 | | | IN. (760 MM BY 1220 MM) COMPLYING WITH | | | 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH.THE CLEAR FLOOR SPACE SHALL | | | BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 IN. (485 MM) | | | UNDERNEATH THE SINK (SEE FIGURE | | | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-01-09 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-01-09 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-01-09 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2006-01-09 00:00:00 | PAUL SCHMITZ | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | DENIED | | | | | | 1) SHT 1-100 DEMOLITION | | | SEPERATE PERMIT REQUIRED. | | | SEC.704.5 DEAD ENDS.ADD NOTE ON PLANS. | | | IN THE INSTALLATION OR REMOVAL OF ANY | | | PART OF A DRAINAGE SYSTEM, DEAD ENDS | | | SHALL BE PROHIBITED. | | | | | | 2) SHT-P1.01 RM #114 BREAK ROOM SINK | | | PROVIDE A DETAIL, ?11-4.24 SINKS. | | | ?11-4.24.1 GENERAL. SINKS REQUIRED TO | | | BE ACCESSIBLE BY ?11-4.1 SHALL | | | COMPLY WITH ?11-4.24. | | | ?11-4.24.2 HEIGHT. SINKS SHALL BE | | | MOUNTED WITH THE COUNTER OR RIM NO | | | HIGHER THAN 34 IN. (865 MM) ABOVE THE | | | FINISH FLOOR. | | | ?11-4.24.3 KNEE CLEARANCE. KNEE | | | CLEARANCE THAT IS AT LEAST 27 IN. (685 | | | MM) HIGH, 30 IN. (760 MM) WIDE, AND 19 | | | IN (485 MM) DEEP SHALL BE | | | PROVIDED UNDERNEATH SINKS. | | | ?11-4.24.4 DEPTH. EACH SINK SHALL BE A | | | MAXIMUM OF 6-1/2 IN (165 MM) | | | DEEP. | | | ?11-4.24.5 CLEAR FLOOR SPACE. A CLEAR | | | FLOOR SPACE AT LEAST 30 IN. BY 48 | | | IN. (760 MM BY 1220 MM) COMPLYING WITH | | | 11-4.2.4 SHALL BE PROVIDED IN | | | FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH.THE CLEAR FLOOR SPACE SHALL | | | BE ON AN ACCESSIBLE ROUTE AND SHALL | | | EXTEND A MAXIMUM OF 19 IN. (485 MM) | | | UNDERNEATH THE SINK (SEE FIGURE | | | 11-32). | | | ?11-4.24.6 EXPOSED PIPES AND SURFACES. | | | HOT WATER AND DRAIN PIPES EXPOSED | | | UNDER SINKS SHALL BE INSULATED OR | | | OTHERWISE CONFIGURED SO AS TO PROTECT | | | AGAINST CONTACT.THERE SHALL BE NO | | | SHARP OR ABRASIVE SURFACES UNDER | | | SINKS. | | | ?11-4.24.7 FAUCETS. FAUCETS SHALL | | | COMPLY WITH ?11-4.27.4.LEVER- | | | OPERATED, PUSH-TYPE, TOUCH-TYPE, OR | | | ELECTRONICALLY CONTROLLED MECHANISMS | | | ARE ACCEPTABLE DESIGNS. | | | 3) TAB 403 MINIMUM FACILITIES. | | | ONE DRINKING FOUNTAIN REQUIRED. | | | SEC. 404 ACCESSIBLE PLUMBING FIXTURES | | | PROVIDE A DETAIL, SEE FIG. 404.2.2 | | | END OF COMMENTS, QUESTIONS 561-805-6692 | | | |
|
|