| Plan Review Stops For Permit 05100635 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-16 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-16 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | NEEDS SUITE # |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-09-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-09-29 |
Time |
11:06 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-09-29 |
Time |
08:38 |
Sent To |
PC |
|
| Notes |
| 2006-09-29 00:00:00 | REVISION# 3 & 4. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-06-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-06-20 |
Time |
07:28 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2006-06-20 |
Time |
07:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-03-01 |
Time |
17:45 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2006-03-01 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2006-03-01 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05100635 | | | ADD: 1661 WORTHINGTON RD | | | CONT: "PLAN REVIEW" | | | TEL: (954)689-6905 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | | | | 1) OK! | | | | | | 2)OK! | | | 2A)OK! | | | 2B) FL ADMINISTRATIVE CODE 481.219 | | | REQUIRES THE ARCHITECTURAL FIRM TO HAVE | | | THEIR CERTIFICATE OF AUTHORIZATION | | | NUMBER IN TITLEBLOCK. | | | 2C) 471.023 F.S.CERTIFICATE OF | | | AUTHORIZATION.THE TITLE BLOCK FOR ANY | | | SHEET BEARING THE NAME OF AN ENGINEER | | | PRACTICING UNDER A FICTITIOUS NAME, A | | | CORPORATION, OR A PARTNERSHIP, OFFERING | | | ENGINEERING SERVICES, SHALL INCLUDE THE | | | CERTIFICATE OF AUTHORIZATION NUMBER. | | | ADD THE NUMBER TO EACH SHEET.THIS MAY | | | BE ADDED BY HAND. | | | | | | | | | BUILDING PLANS APPEAR TO BE CODE | | | COMPLIANT!!! | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-01-19 |
Time |
08:59 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2006-01-19 |
Time |
08:59 |
Sent To |
PC |
|
| Notes |
| 2006-01-19 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05100635 | | | ADD: 1661 WORTHINGTON RD | | | CONT: "PLAN REVIEW" | | | TEL: (954)689-6905 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | 1) 106.1.2 ADDITIONAL DATA. THE BUILDING | | | OFFICIAL MAY REQUIRE ALL DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | REQUIRED BY THE BUILDING OFFICIAL TO BE | | | ASSEMBLED INTO PERMIT READY SETS OF | | | PLANS. PLANS ARE LOOSE AND UNORGANIZED. | | | | | | 2)SEE THE VARIOUS REVIEWERS COMMENTS ON: | | | 2A) ORIGINAL PLANS STILL HAVE RUBBER | | | STAMP SEAL, NOT THE REQUIRED RAISED | | | EMBOSSED SEAL. | | | 2B) FL ADMINISTRATIVE CODE 481.219 | | | REQUIRES THE ARCHITECTURAL FIRM TO HAVE | | | THEIR CERTIFICATE OF AUTHORIZATION | | | NUMBER IN TITLEBLOCK. | | | | | | 3)COMMENT# 3 FROM THE PREVIOUS REVIEW | | | DELT WITH NO INFORMATION ON THE KITHEN | | | CABINETS AND SINK. | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL | | | BE MOUNTED WITH THE COUNTER NO HIGHER | | | THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARENCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2005-11-21 |
Time |
13:20 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2005-11-21 |
Time |
13:20 |
Sent To |
|
|
| Notes |
| 2005-11-21 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05100635 | | | ADD: 1661 WORTHINGTON RD | | | CONT: "PLAN REVIEW" | | | TEL: (954)689-6905 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS DO NOT INDICATE AS TO WHAT CODE | | | THEY WERE DESIGNED TOO?SEE 110.2 | | | INFORMATION REQUIRED FOR CERTIFICATE OF | | | OCCUPANCY, SEE 12 ITEMS THAT WILL BE | | | REQUIRED FOR PERMIT ISSUANCE AND C.O. | | | | | | 2)SHEET A-200 FLOOR PLAN HAS VARIOUS | | | DOORS THAT DOESN'T COMPLY WITH THE | | | MANEUVERING CLEARENCES AT DOORWAYS. | | | SEE THE REQUIRED 18" AT THE LATCH ON THE | | | PULL SIDE OF THE DOOR. | | | 11-4.13.6 MANEUVERING CLEARANCES AT | | | DOORS. MINIMUM MANEUVERING | | | CLEARANCES AT DOORS THAT ARE NOT | | | AUTOMATIC OR POWER-ASSISTED SHALL BE AS | | | SHOWN IN FIGURE 11-25.THE FLOOR OR | | | GROUND AREA WITHIN THE REQUIRED | | | CLEARANCES SHALL BE LEVEL AND CLEAR. | | | DOORS 106, 107,108,KITCHEN CLOSET DOOR | | | 109, 114B, 115 & 119. | | | | | | 3) KITCHEN(109) PROVIDE ELEVATIONS OF | | | COUNTER W/ SINK, COMPLY WITH: | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL | | | BE MOUNTED WITH THE COUNTER NO HIGHER | | | THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARENCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | | | | 4)PROVIDE THE MINIMUM INTERIOR FINISH | | | CLASSIFICATION.TABLE 803.5 | | | MINIMUM INTERIOR FINISH CLASSIFICATION; | | | PROVIDE INFORMATION BASED ON INTERIOR | | | FINISH REQUIREMENTS BASED ON OCCUPANCY. | | | | | | 5) FL BLD CODE 104.2.1.2 | | | ADDITIONAL INFORMATION REQUIRED,VARIOUS | | | SHEETS INDICATE DIFFERENT TYPES OF | | | STRUCTURAL COMPONENTS ABOVE THE FINISH | | | CEILING A003 INDICATES DECK WITH NO TYPE | | | DECLARED, A9.10 INDICATES A CONCRETE | | | DECK AND P2.01 INDICATES BAR JOIST. | | | SHEET A-400 INDICATES VARIOUS DROPPED | | | DRYWALL CEILINGS BUT NO MENTION AS TO | | | TYPE OF DECK ABOVE, TYPE OF FASTENER, | | | SPACING OF FRAMING, TYPE OF FRAMING, | | | IF STIFF BACKS ARE REQUIRED NOR THE | | | THICKNESSS OF DRYWALL? | | | | | | 6)A006 WALL FINISH SCHEDULE DOESN'T | | | INDICATE EALL FINISH IN RESTROOMS, SEE | | | REQUIREMENTS 1210.2 FOR A SMOOTH,HARD | | | AND NONABSORBANT SURFACE TO A HEIGHT OF | | | 4'-0" AT WATERCLOSETS & URINALS. | | | | | | 7) CORRECT ENERGY FORM TO THE FORM 400A | | | 2004 EDITION. | | | | | | 8) LETTER OF AUTHORIZATION FROM BANK | | | INDICATES EXTERIOR MODIFICATIONS? | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2006-11-13 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-13 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-13 |
Time |
11:41 |
Sent To |
PC |
|
| Notes |
| 2006-11-13 12:00:52 | *** REV #9,,, | | | | | | | | | | | | STILL REDLINED TRANSFORMER LOCATION AS PLANS ONLY | | | MENTION TO BE MOUNTED ABOVE PANEL. THIS SIZE OF | | | TRANSFORMER MUST NOT BE ABOVE CEILING. 450.13B. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-22 |
Time |
19:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-22 |
Time |
19:18 |
Sent To |
PC |
|
| Notes |
| 2006-09-22 00:00:00 | REV, LOCATIONS AND SOME CIRCUITING. | | | REDLINED TRANSFORMER TO BE SURE IT IS | | | NOT ABOVE CEILING PER 450.13 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-11 |
Time |
20:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-11 |
Time |
20:02 |
Sent To |
M |
|
| Notes |
| 2006-08-11 00:00:00 | ELECTRICAL STAMPED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
F |
Date |
2006-07-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-27 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-27 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2006-07-27 00:00:00 | ***UNSAT *** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW. | | | | | | ** PLEASE KNOW ANY "EARLY WORK RELEASE" | | | GRANTED BY THE BUILDING OFFICAL WAS AT | | | CONTRACTOR'S OWN RISK. | | | | | | | | | 1 NOTE: PLEASE SEE REQUIREMENTS FOR | | | FBC CHAPTER 13 ARE REQUIRED TO BE MET | | | FOR ALL LIGHTING. | | | 13-415.1.ABC.1.1, 13-415.1.ABC.1.2 ETC | | | PLEASE SEE THE OVER RIDE SWITCHES | | | MUST STATE A MAXIMUM OF 4HRS AND A MAX | | | OF 30 MINS FOR MOTION SENSORS FOR | | | DEVICES AND LOCATIONS. | | | PLEASE SEE WORST CASE VD COULD NOT BE | | | LOCATED FOR ANY ONE BRANCH CIRCUIT. OR | | | FEEDER? 13-413 | | | PLEASE KNOW, A "SWITCH" IS NOT A DEVICE | | | FOR CONTROL. IT MUST BE PART OF THE | | | SYSTEM AND SHALL HAVE LIMITS TO TIME | | | ETC. PLEASE BE SURE TO LIST THE TIMES | | | FOR MAX OVER RIDE. | | | ** PLEASE SEE CALCS FOR 13-415.1.AB.1, | | | 13-415.2.ABC.1, TABLES 415.2.C.1, | | | 415.2.B.1. | | | PLEASE SEE CALCULATIONS SUBMITTED ARE | | | THE SAME ONES FROM 2/27/06 AND HAVE NOT | | | BEEN REVISED TO INCLUDE LIGHITNG DESIGN | | | (DESIGN WATTAGE) DESIGN MAX ALLOWANCE( | | | PERMITTED LPD'S PER TABLES) ETC., | | | PLEASE ALSO SEE IT WAS NOTED ON PREVIOUS | | | REVIEW FROM THE MECHANICAL REVIEWER THAT | | | THE CALCULATIONS WERE SEALED | | | "PHOTO-COPIES" OF SIGNED DOCUMENTS. | | | PLEASE SEE FS 471.025, FBC CHAPTER 13 AS | | | THESE ARE REQUIRED TO CONTAIN THE | | | "ORIGINAL" SIGNATURE , DATE AND RAISED | | | SEAL FOR THE DESIGNER OF RECORD. MAY NOT | | | PLACE A "RAISED SEAL" OVER PHOTO-COPIED | | | SIGNATURES. | | | | | | PLACED TWO PHONE CALLS TO CONTRACTOR ETC | | | WITH RESPECT TO CALCULATIONS. | | | | | | 2) NOTE: PLEASE COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS FROM SETS AND ONLY | | | INSERT NEW REVISED SHEETS INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. | | | PLEASE SEE THAT ALL OLD/VOIDED SHEETS | | | WERE LEFT IN SETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW.ONCE AGAIN IF THERE ARE ANY | | | QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-09 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-09 |
Time |
17:27 |
Sent To |
|
|
| Notes |
| 2006-06-09 00:00:00 | ***UNSAT *** | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEWS AND NOTES PER NEW FBC 2004 | | | CHAPTER 13. | | | | | | ** PLEASE KNOW, EARLY WORK RELEASE WHICH | | | WAS GRANTED BY THE BUILDING OFFICIAL WAS | | | AT OWNER/CONTRACTORS OWN RISK. | | | | | | | | | 1) NOTE: PLEASE SEE PREVIOUS NOTE WITH | | | RESPECT TONEC 645, NFPA-75. | | | PLEASE SEE MEANS OF SHUTTING DOWN ALL | | | ELECTRICAL, A/C SYSTEMS AND SEPARATIONS | | | COULD NOT BE LOCATED ON PLANS. | | | 645.1-645.16 NFPA-75 PLEASE SEE ALL | | | CHAPTERS | | | ** PLEASE SEE THIS REVIEW COMMENT HAS | | | BEEN REPEATED THREE TIMES AND A NOTICE | | | TO FS 553.80(2)(B) WAS GIVEN ON THE | | | PREVIOUS REVIEWS WITH RESPECT TO REPEAT | | | COMMENTS THREE OR MORE TIMES. PLEASE | | | KNOW AS THE FIRST TWO REVIEWS WERE "PLAN | | | REVIEW"ONLY, IF THIS COMMENT IS NOT | | | ADDRESSED ON THE FOLLOWING REVIEW A 4X | | | PLAN REVIEW FEE WILL BE ASSESSED. | | | | | | 21) NOTE: PLEASE SEE REQUIREMENTS FOR | | | FBC CHAPTER 13 ARE REQUIRED TO BE MET | | | FOR ALL LIGHTING. | | | 13-415.1.ABC.1.1, 13-415.1.ABC.1.2 ETC | | | PLEASE CLARIFY AS SOME OF THIS IS BEING | | | SHOWN, BUT UNCLEAR AS MANY LIGHTING | | | CIRCUITS DO NOT INDICATE ANY CONTROL? | | | PLEASE ALSO SEE THE OVER RIDE SWITCHES | | | MUST STATE A MAXIMUM OF 4HRS AND A MAX | | | OF 30 MINS FOR MOTION SENSORS. | | | PLEASE SEE THE OVER RIDING SWITCHES | | | SHALL BE LOCATED IN THE AREAS FOR | | | LIGHTING WHICH CAN BE SEEN BY THE | | | OCCUPANT. A NOTE ON THE PLAN MENTIONS AN | | | OVER RIDE SWITCH IN THE ELECTRICAL | | | CLOSET WHICH WILL NOT BE ACCEPTED. | | | PLEASE SHOW LOCATIONS OF ALL OVER RIDES | | | AND OCC SENSORS. | | | ** PLEASE SEE A WORST CASE SCENARIO | | | SHALL BE SHOWN FOR VOLTAGE DROP PER | | | 13-413.1.ABC.1 | | | **PLEASE ALSO SEE 13-415.1.ABC.1.3 FOR | | | OTHER LIGHTING INSEPARATE SPACES | | | /ROOMS AREAS. | | | PLEASE KNOW, A "SWITCH" IS NOT A DEVICE | | | FOR CONTROL. IT MUST BE PART OF THE | | | SYSTEM AND SHALL HAVE LIMITS TO TIME | | | ETC. | | | ** PLEASE SEE CALCS FOR 13-415.1.AB.1 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-02-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-08 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-08 |
Time |
19:38 |
Sent To |
I |
|
| Notes |
| 2006-02-08 00:00:00 | ********* UNSAT 2ND REVIEW ******* | | | | | | 1)NOTE: PLEASE SEE ALMOST ALL COMMENTS | | | FROM PREVIOUS REVIEW STILL APPLY. | | | PLEASE SEE IT SEEMS ONLY COMMENTS #1 AND | | | #3 WERE ADDRESSED. | | | | | | ** PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW. PLEASE | | | ALSO SEE ONE NEW NOTE WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | | | | | | | | ******** UNSAT ********* | | | | | | | | | | | | | | | 1)NOTE: OK | | | | | | | | | ************************************* | | | 2)NOTE: PLEASE SEE MISSING LICENSE | | | INFORMATION REQUIRED FOR ARCHITECTUAL | | | FIRM ON TITLE BLOCKS. | | | PLEASE SEEFLORIDA ADMINISTRATIVE CODE | | | 61G1-16.004 AND FS 481.219. | | | PLEASE KNOW, THIS IS REQUIRED FOR ALL | | | TRADES AND FOR ALL SHEETS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | *************************************** | | | 3)NOTE: OK | | | | | | | | | | | | | | | | | | *************************************** | | | | | | 4)NOTE: PLEASE SEE 645.2,645.10,645.15 | | | ETC FOR MISSING REQUIRED INFORMATION FOR | | | "IT" ROOM. | | | PLEASE SEE ELECTRICAL REQUIREMENTS PER | | | NFPA-70 AND NFPA-75 | | | | | | PLEASEALSO SEEMISSING FIRE RATING OF | | | RM, FIRE/SMOKE DAMPERS ETC REQUIRED. | | | | | | 5)NOTE: PLEASE SEE PLANS INCLUDING | | | A-SHEETS REFERENCE A 2004 ELECTRICAL | | | CODE. | | | PLEASE SEE AS OF JULY 1ST,2003 WE ARE | | | UNDER THE 2002 NEC. | | | **NOTE, THE NEXT ELECTRICAL CODE WILL BE | | | THE 2005 NOT YET ADOPTED BY THE STATE. | | | | | | 6)NOTE: PLEASE PROVIDE LOAD CALCULATIONS | | | FOR NEW ADDED LOADS TO EXISTING SERVICE. | | | NONE SUBMITTED. | | | 220,220.3,220.10,220.11,220.13, ETC | | | CONTINUOUS LOADS 215.3, 230.42 | | | | | | 7)NOTE: PLEASE SEE 210.8B3 FOR KITCHENS | | | IN OTHER THAN DWELLING UNITS. | | | | | | *************************************** | | | NEW NOTE: | | | | | | 1)NOTE: PLEASE SEE COPY OF FLORIDA | | | STATUES 553.80(2)(3) WITH RESPECT TO | | | DESIGN PROFESSIONALS AND REPEAT COMMENTS | | | THREE OR MORE TIMES. PLEASE BE SURE ALL | | | COMMENTS ARE ADDRESSED. | | | | | | | | | 2)NOTE: PLEASE COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW | | | REVISED SHEETS INTO TWO COMPLETE SETS | | | FOR REVIEW AND STAMPING. | | | PLEASE BE SURE TO SUBMIT ONE COPY OF | | | OLD/VOIDED SHEETS FOR REFERENCE. | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-01-03 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-01-03 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | ******** UNSAT ********* | | | | | | | | | ** PLANS ONLY SUBMITTED FOR "PLAN | | | REVIEW" AND NOT FOR PERMIT. | | | | | | 1)NOTE: PLEASE SUBMIT COMPLETE ATTACHED | | | SETS FOR REVIEW AND STAMPING. | | | PLEASE SEE EACH SET CONTAINS ALL LOSE | | | SHEETS AND NOTHING IS ATTACHED. | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS FROM | | | SETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO COMPLETED SETS. | | | ONE SET OF OLD/VOIDED SHEETS SHOULD BE | | | SEPARATE FOR REFERENCE. | | | | | | | | | ************************************* | | | 2)NOTE: PLEASE SEE MISSING LICENSE | | | INFORMATION REQUIRED FOR ARCHITECTUAL | | | FIRM ON TITLE BLOCKS. | | | PLEASE SEEFLORIDA ADMINISTRATIVE CODE | | | 61G1-16.004 AND FS 481.219. | | | PLEASE KNOW, THIS IS REQUIRED FOR ALL | | | TRADES AND FOR ALL SHEETS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | *************************************** | | | 3)NOTE: PLEASE SEE MANY ARCHITECTUAL | | | SHEETS CONTAIN A "RUBBER STAMP" FOR THE | | | ARCHITECT'S REQUIRED "RAISED/IMPRESSION" | | | TYPE SEAL. | | | PLEASE SEE FS 481.221 | | | THIS IS REQUIRED OF ALL SHEETS. PLEASE | | | SEE SOME SHEETS DO CONTAIN THE REQUIRED | | | "RAISED SEAL". | | | *************************************** | | | | | | 4)NOTE: PLEASE SEE 645.2,645.10,645.15 | | | ETC FOR MISSING REQUIRED INFORMATION FOR | | | "IT" ROOM. | | | PLEASE SEE ELECTRICAL REQUIREMENTS PER | | | NFPA-70 AND NFPA-75 | | | | | | PLEASEALSO SEEMISSING FIRE RATING OF | | | RM, FIRE/SMOKE DAMPERS ETC REQUIRED. | | | | | | 5)NOTE: PLEASE SEE PLANS INCLUDING | | | A-SHEETS REFERENCE A 2004 ELECTRICAL | | | CODE. | | | PLEASE SEE AS OF JULY 1ST,2003 WE ARE | | | UNDER THE 2002 NEC. | | | **NOTE, THE NEXT ELECTRICAL CODE WILL BE | | | THE 2005 NOT YET ADOPTED BY THE STATE. | | | | | | 6)NOTE: PLEASE PROVIDE LOAD CALCULATIONS | | | FOR NEW ADDED LOADS TO EXISTING SERVICE. | | | NONE SUBMITTED. | | | 220,220.3,220.10,220.11,220.13, ETC | | | CONTINUOUS LOADS 215.3, 230.42 | | | | | | 7)NOTE: PLEASE SEE 210.8B3 FOR KITCHENS | | | IN OTHER THAN DWELLING UNITS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-11-14 |
Time |
20:24 |
Rev Time |
1.30 |
| Received By |
jleahy |
Date |
2005-11-14 |
Time |
20:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-21 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-21 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | ***APPROVED*** | | | | | | PLEASE SHOW LOCATION OF FACP WHEN | | | SUBMITTING FOR FIRE ALARM PERMIT. SMOKE | | | DETECTOR IS REQUIRED IN AREA OF PANEL. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2005-12-30 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-12-30 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-12-30 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-16 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-16 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2005-11-16 00:00:00 | ******DENIED****** | | | | | | 1) EACH SHEET OF THE DRAWINGS ARE TO BE | | | SIGNED, DATED AND SEALED IN ACCORDANCE | | | WITH FS REQUIREMENTS. | | | | | | 2) LIFE SAFETY TO COMPLY WITH NFPA-101, | | | AND NFPA-1, 2003 EDITIONS. | | | | | | 3) PLEASE INDICATE THE INTERIOR FINISH | | | CLASSIFICATION OF WALLS AND CEILING IN | | | TERMS OF CLASS A, B OR C. | | | | | | 4) IN ACCORDANCE WITH LOCAL | | | REQUIREMENTS, DUCT SMOKE DETECTORS SHALL | | | INITIATE A GENERAL FIRE ALARM, NOT | | | SUPERVISORY SIGNAL WHEN ACTIVATED. | | | | | | 5) IN ADDITION TO THE FIRE SPRINKLER | | | SYSTEM, SEPARATE SHOP DRAWINGS AND | | | PERMITS ARE REQUIRED FOR FIRE ALARM | | | REMODEL. | | | | | | 6) PLEASE NOTE THE LOCATIONS OF REQUIRED | | | 2A-10B,C RATED FIRE EXTINGUISHERS, THAT | | | SHALL NOT EXCEED 75' TRAVEL DISTANCE. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2006-11-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-07 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-07 |
Time |
15:46 |
Sent To |
E |
|
| Notes |
| 2006-11-07 15:47:02 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
11:37 |
Sent To |
E |
|
| Notes |
| 2006-09-18 00:00:00 | TO "DPALMER' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-09-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-18 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-18 |
Time |
11:20 |
Sent To |
P |
|
| Notes |
| 2006-09-18 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-09-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-12 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-12 |
Time |
08:46 |
Sent To |
B |
|
| Notes |
| 2006-09-12 00:00:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-07 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-07 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2006-08-07 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-14 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-14 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2006-07-27 00:00:00 | TO "COMM' BD#31 | | 2006-07-14 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-03 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-03 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | TO "COMM" BD#60 | | 2006-05-03 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-01-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-26 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-26 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2006-02-22 00:00:00 | TO "COMM" BD#31 | | 2006-01-26 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-28 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-28 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2005-12-28 00:00:00 | TO "BOB"#2 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-01-06 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-11-22 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-10-18 |
Time |
09:59 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | TO "BOB"#2 | | 2005-10-18 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2006-08-16 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-16 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-16 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-11 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-11 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | CALLED ENGINEER (BOB FORMICA), | | | ARCHITECTURAL PLANS WERE REVISED TO | | | WHICH NOW THE MECHANICAL PLANS ARE NO | | | LONGER CODE COMPLIANT.DUCTS | | | PENETRATING FIRE RATED WALLS OR | | | PARTITIONS SHALL BE PROTECTED BY FIRE | | | DAMPERS 2004 FMC 607.5.3. | | | | | | FLEX DUCTS ARE NOT PERMITTED TO | | | PENETRATE RATED WALLS OR PARTITIONS PER | | | 2004 FMC 607.7 | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-04 |
Time |
11:09 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-08-04 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2006-08-04 00:00:00 | *** DENIED *** | | | 1) SEE LAST MECHANICAL REVIEW (COPY). | | | MECHANICAL PLANS NOT REVIEWED AT THIS | | | TIME. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-06-21 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-06-21 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | DENIED: | | | | | | THE ENERGY CALCULATIONS SUBMITTED ARE | | | COPIES.PLEASE SUBMIT ORIGIANL | | | SIGNATURE, DATE ON THE EMBOSSED DEALED | | | AS REQUIRED PER FS 471.025 & FAC | | | 61G15-23.002. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-02-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-02-27 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-02-27 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2006-02-27 00:00:00 | DENIED: | | | 2ND REQUEST | | | COMMENT #2 BY TOM GORDON (1-3-06), WAS | | | NOT ADDRESSED; PLEASE PROVIDE ENERGY | | | CALCULATIONS PER 2004 FBC CHAPTER 13 | | | SUB-CHAPTER 4. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-01-03 |
Time |
16:43 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-01-03 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | *** DENIED *** | | | 1) ARCTITECTUAL LICENSE NUMBER MISSING | | | FROM TITLE BLOCK. SEE ELECT. NOTE #2. | | | | | | 2) ENERGY CAL'S NEEDED FOR PROPER | | | MECHANICAL REVIEW. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-11-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-11-21 |
Time |
17:33 |
Rev Time |
1.50 |
| Received By |
rregueir |
Date |
2005-11-21 |
Time |
16:18 |
Sent To |
PC |
|
| Notes |
| 2005-11-21 00:00:00 | ----------------PROVISO----------------- | | | | | | 1.NO ROOF PLAN PROVIDED. ENSURE THAT | | | THERE | | | ARE NO PLUMBING VENTS OR EXHAUST OUTLETS | | | WITHIN 10 FEET OF RTU OUTSIDE AIR | | | INTAKES. | | | | | | 2.MECHANICAL PLAN SHOWS EF 2 (SEE FAN | | | SCHEDULE) IN GANG BATHROOMS AND EF 1 IN | | | CLOSET.ELECTRICAL PLAN CALLS FOR THE | | | REVERSE.EF 2 IS THE CORRECT FAN FOR | | | THE GANG BATHROOMS. | | | | | | ANY QUESTIONS PLEASE CALL RONALD J | | | REGUEIRO AT 561-805-6734 OR | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-10-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-10-14 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-10-14 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2006-10-14 06:35:04 | REVISION; | | | CHANGED WATER HEATERAND DRYWELL LOCATIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-06-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-06-22 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-03-16 |
Time |
10:53 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2006-03-16 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2006-03-16 00:00:00 | DENIED; | | | 1. PLEASE SEE MISSING LICENSE | | | INFORMATION REQUIRED FOR ARCHITECTUAL | | | FIRM ON TITAL BLOCK. | | | 2.PAGE A-942 ELEVATION M-15 DOES NOT | | | COMPLY WITH FBC-2004 CHAPTER 11 SEC'S | | | 11-4.23.3 KNEE CLEARANCE AND 11-4.24.7, | | | PLEASE SHOW FAUCET HANDLES OR ADD NOTE. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-01-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-01-03 |
Time |
12:13 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2006-01-03 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2006-01-03 00:00:00 | DENIED; | | | BREAK SINK DETAIL DOES NOT MEET FBC-2004 | | | CHAPTER 11 HANDICAP CODE. SEC. 11-4.24.1 | | | THRU 11-4.24.7. KICK PLAT AND DOORS | | | CANNOT BE INSTALLED AS SHOWN AND MEET | | | SEC.11-4.24.3 (KNEE CLEARANCE) FOR A | | | FORWARD APPROACH. | | | PLEASE SHOW DETAIL OF HANDICAP DRINKING | | | FOUNTAIN. SEE FIGURE 27. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2005-11-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-11-17 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2005-11-17 00:00:00 | PAUL SCHMITZ | | | FBC 2004 PLUMBING CODE PLAN REVIEW | | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | | DENIED | | | 1)SHT P1.01 A/C CONDENSATE DISPOSAL: | | | OPTIONS RTU TO ROOF DRAINS. | | | IF BELOW ROOF TERMINATE TO STORM | | | OUTSIDE OF BUILDING, | | | PLANTER OR DRY WELL. | | | 2)SHT P2.01 DETAIL WATER HEATER: | | | SEC 607.3 PROVIDE INFORMATION FOR | | | THERMAL EXPASNSION CONTROL. | | | 3)SHT P2.01 WATER RISER: | | | EXPLAIN ABBREVIATION WATTS BRVT. | | | SHOW ON PLUMBING LEGEND. | | | 4) SEC 403 MINIMUM REQUIRED NUMBER OF | | | PLUMBING FIXTURES. | | | PLUMBING FIXTURES SHALL BE PROVIDEDFOR | | | THE TYPE OF OCCUPANCY AND THE MINIMUM | | | NUMBER SHOWN IN TABLE 403.1 | | | SEC 410 DRINKING FOUNTAINS.1-PER 100 | | | END OF COMMENTS QUESTIONS 561-805-6692 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-03-14 |
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|