| Plan Review Stops For Permit 05100303 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
P |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-09-14 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-09-14 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2007-09-14 08:56:08 | PRIVACY WALL AND GATE REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-07-19 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-19 |
Time |
15:54 |
Sent To |
Z |
|
| Notes |
| 2007-07-19 15:41:06 | REVISION FOR SITE WALLOK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-06-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-06-07 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-06-07 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2007-06-07 12:02:10 | REVISION FOR WINDOWS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-03-07 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-07 |
Time |
18:32 |
Sent To |
|
|
| Notes |
| 2007-03-07 18:33:17 | | | | SKYLIGHT REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2006-09-28 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-09-28 |
Time |
10:27 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2006-09-28 |
Time |
10:27 |
Sent To |
|
|
| Notes |
| 2006-09-28 00:00:00 | RESTAMPED PLANS OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-31 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2006-07-31 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2006-07-31 00:00:00 | REVISION OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-04-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-04-20 |
Time |
09:26 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-04-20 |
Time |
09:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-03-27 |
Time |
13:37 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2006-03-27 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2006-03-27 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 5. ALL QUALITY ASSURANCE IS NOW MISSING, | | | (MIAMI-DADE) FOR EXAMPLE. | | | TWO COPIES OF THESE SHOULD BE ATTACHED | | | TO YOUR STATE PRODUCT APPROVALS. | | | ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-23 |
Time |
15:40 |
Rev Time |
1.50 |
| Received By |
alange |
Date |
2006-02-23 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2006-02-23 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | SUBMIT ENERGY CALCS TO THE 2004 FBC | | | | | | 5.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-22 |
Time |
10:32 |
Rev Time |
3.66 |
| Received By |
alange |
Date |
2005-12-22 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SUBMIT ENERGY CALCS TO THE 2004 FBC | | | | | | 4.SUBMIT PRODUCT APPROVALS FOR | | | ROOFING, STRAPS AND TIE-DOWNS AND | | | LINTELS. | | | | | | 5.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6. SUBMIT A GUARDRAIL DETAIL SHOWING | | | COMPLIANCE WITH R312.1 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2007-11-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-11-01 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-11-01 |
Time |
06:33 |
Sent To |
PC |
|
| Notes |
| 2007-11-01 07:49:02 | | | | | | | | | | | | | PROVISO | | | | | | PRIOR TO FINAL ELECTRICAL INSPECTION SUBMIT A SITE PLAN | | | AND SURVEY INDICATING THE LOCATION OF THE GENERATOR NOW | | | REMOVED FROM THE PLAN, SHEET E1. THIS LOCATION NEEDS TO | | | HAVE A ZONING, ELECTRICAL, MECHANICAL AND BUILDING | | | REVIEW FOR SETBACKS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-16 |
Time |
14:22 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-02-16 |
Time |
13:58 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-04-11 |
Time |
16:43 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2006-04-11 |
Time |
16:37 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-23 |
Time |
17:52 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2006-03-23 |
Time |
17:20 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-02-14 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-02-14 |
Time |
12:25 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2006-02-14 |
Time |
11:04 |
Sent To |
M |
|
| Notes |
| 2006-02-14 00:00:00 | | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE PROVIDE MANUFACTURERS | | | SPECIFICATIONS FOR THE GENERATOR AND | | | TRANSFER SWITCH. | | | | | | 2} SMOKE DETECTORS ARE REQUIRED TO BE | | | INSTALLED IN THE GAME ROOM ( SINCE IT IS | | | COMPARTMENTED FROM THE REST OF THE UPPER | | | FLOOR, AND THEREFORE OTHER DETECTORS) | | | AND ON THE FIRST FLOOR. FBC RES. 313.1 | | | | | | 3} THE PANEL(A)INDICATES IT IS 400 AMP | | | RATED, THE RISER INDICATES 200 AMPS. | | | PLEASE CORRELATE. | | | | | | 4} PLEASE CHECK AND CORRELATE THE A/C | | | AND AHU LOADS WITH THE MECHANICAL PLAN. | | | NOTE THE COMPRESSER LOADS ARE SHOWN | | | LARGER THAN THE AHU LOADS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2005-11-15 |
Time |
12:18 |
Rev Time |
1.50 |
| Received By |
btrobaug |
Date |
2005-11-15 |
Time |
06:42 |
Sent To |
M |
|
| Notes |
| 2005-11-15 00:00:00 | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | | REVIEW. | | | | | | 1} PLEASE PROVIDE MANUFACTURERS | | | SPECIFICATIONS FOR THE GENERATOR AND | | | TRANSFER SWITCH. | | | | | | 2} THE #5 BARE COPPER GEC IS NOT A AWG | | | SIZE. GEC MUST BE A MINIMUM OF #1/0 PER | | | 250.66. | | | | | | 3} THE GROUNDING ELECTRODE SYSTEM MUST | | | COMPLY WITH 250.50. 250.52(A)(3) | | | INDICATES HOW THE GEC MUST BE CONNECTED | | | TO BUILDING (FOOTER) STEEL, PLEASE | | | INDICATE SAME ON THE PLAN. | | | | | | 4} INDICATE DISCONNECTING MEANS PER | | | 230.71. THE PANELS SHOWN ON THE RISER DO | | | NOT SPECIFY MAIN BREAKERS. | | | | | | 5} PLEASE SHOW THE LOCATION OF ALL | | | SERVICE AND GENERATOR EQUIPMENT ON THE | | | FLOOR PLAN. THE RISER SHOWS A GUTTER, | | | THIS AND THE TRANSFER SWITCH ARE NOT | | | LOCATED ON THE PLAN, AND PANELS ARE | | | SHOWN INSIDE? | | | | | | 6} PLEASE SIZE THE GUTTER SO THAT | | | COMPLIANCE WITH ARTICLE 366 CAN BE | | | DETERMINED. | | | | | | 7} PLEASE NOTE THE GENERATOR MUST BE | | | GROUNDED PER MANUFACTURERS SPEC'S.THIS | | | IS NOT A SEPARATELY DERIVED SYSTEM AND | | | MUST USE THE SERVICE NEUTRAL AND GROUND, | | | THE GENERATOR NEUTRAL CANNOT BE BONDED | | | TO THE FRAME AND THEN TO A ROD. THIS IS | | | JUST A NOTE AS IT HAS BEEN BROUGHT TO MY | | | ATTENTION BY CONTRACTORS THAT THESE | | | MODELS HAVE A JUMPER FROM THE NEUTRAL TO | | | THE FRAME, WHICH OF COURSE MUST BE | | | REMOVED WHEN USING A TWO POLE SWITCH. | | | | | | 8} REGARDING CIRCUIT A8, PLEASE SEE | | | 210.11(C)(3) 20 AMP.THAT CIRCUIT IS | | | CONFINED TO A SINGLE BATHROOM OR TO ALL | | | BATH GFI'S ONLY. THE GFI'S IN THE | | | LAUNDRY MUST NOT BE ON THAT CIRCUIT. | | | ALSO NOTE 1 GFI IN THE MASTER BATH IS ON | | | B4. | | | | | | 9} CIRCUIT #2, PANEL A, DINING ROOM | | | RECEPTACLES MUST COMPLY WITH 210.5(B)(1) | | | & (2), LIVING ROOM CANT BE ON THAT | | | CIRCUIT. | | | | | | 10} ALL OUTLETS, INCLUDING LIGHTING, | | | RECEPTACLES, FANS AND SMOKE DETECTORS | | | INSTALLED IN BEDROOMS MUST BE ARC FAULT | | | PROTECTED PER 210.12. SEE DEFINITION OF | | | "OUTLET" IN ARTICLE 100 FOR | | | CLARIFICATION OF 210.12. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] | | | FAX/:561/659-8026 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2007-11-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-27 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-27 |
Time |
15:40 |
Sent To |
P |
|
| Notes |
| 2007-11-27 15:40:19 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-26 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-26 |
Time |
16:30 |
Sent To |
E |
|
| Notes |
| 2007-10-26 16:31:17 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-10 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-10 |
Time |
09:38 |
Sent To |
B |
|
| Notes |
| 2007-08-10 09:39:47 | TO LM'S OFFICE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-24 |
Time |
13:19 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-24 |
Time |
13:19 |
Sent To |
B |
|
| Notes |
| 2007-06-24 13:20:17 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-15 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-15 |
Time |
09:25 |
Sent To |
HIST |
|
| Notes |
| 2007-05-15 09:26:14 | TO "Z" BOX--TO BE ROUTED TO HISTORIC.--PER "LMARTINEZ" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-24 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-24 |
Time |
14:52 |
Sent To |
B |
|
| Notes |
| 2007-04-24 14:53:05 | TO "LMARTINEZ" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-03-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-15 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-15 |
Time |
11:31 |
Sent To |
M |
|
| Notes |
| 2007-03-15 11:31:29 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-02-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-28 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-28 |
Time |
14:20 |
Sent To |
M |
|
| Notes |
| 2007-02-28 14:20:37 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-02-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-15 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-15 |
Time |
10:48 |
Sent To |
E |
|
| Notes |
| 2007-02-15 10:49:17 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-09 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-09 |
Time |
09:44 |
Sent To |
Z |
|
| Notes |
| 2007-02-09 09:44:27 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-09 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-09 |
Time |
18:54 |
Sent To |
B |
|
| Notes |
| 2006-09-09 00:00:00 | TO "ALANGE" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-07-31 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-07-31 |
Time |
10:29 |
Sent To |
B |
|
| Notes |
| 2006-07-31 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-04-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-11 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-11 |
Time |
09:59 |
Sent To |
E |
|
| Notes |
| 2006-04-11 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-03-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-16 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-16 |
Time |
09:53 |
Sent To |
E |
|
| Notes |
| 2006-03-16 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-02-13 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-15 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-13 |
Time |
09:54 |
Sent To |
E |
|
| Notes |
| 2006-02-13 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-02-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-07 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-07 |
Time |
14:33 |
Sent To |
Z |
|
| Notes |
| 2006-02-07 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-11-10 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-11-10 |
Time |
11:51 |
Sent To |
E |
|
| Notes |
| 2005-11-10 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-22 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-10-11 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2005-10-11 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-16 |
Time |
14:54 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-03-16 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2007-03-16 14:55:19 | REVISION TO MECH. PLANS PAGE M-1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-01 |
Time |
09:27 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-01 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2007-03-01 09:28:19 | REVISION TO MECH. PLANS PAGE M 1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2007-02-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-02-20 |
Time |
10:56 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-02-20 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2007-02-20 11:38:22 | ** MECHANICAL REVISION ** | | | *** DENIED *** | | | 1) DUCT LAY-OUT IS DIFFICULT TO READ. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY. PER 2004 FBC | | | 106.1.1. | | | | | | 2) RETURN AIR NEEDS TO BE PROVIDE FOR THE STUDIO AND | | | LIBRARY, SEE 2004 FBC/R M1602.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-04-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-04-12 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2006-04-13 |
Time |
07:57 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-03-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2006-03-24 |
Time |
16:08 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2006-03-24 |
Time |
12:04 |
Sent To |
E |
|
| Notes |
| 2006-03-24 00:00:00 | *** DENIED *** | | | 1) MANUFACTURE'S SPECIFICATION'S FOR THE | | | GAS CLOTHES DRYER AND THE GAS FIRE PLACE | | | SHOW NO DIRECT VENTING TO PROVIDE | | | COMBUSTION AIR TO THE UNIT, THEY ONLY | | | PROVIDE VENTING FOR EXHAUST. | | | | | | 2) REQUESTING FOR THE SECOND TIME, | | | PLEASE PROVIDE COMBUSTION AIR AND/OR | | | COMB. AIR CALCULATIONS FOR THE GAS | | | CLOTHES DRYER & GAS FIRE PLACE, PER 2004 | | | FBC/R M1703 . | | | | | | 3) REQUESTING FOR THE SECOND TIME, REFER | | | TO YOUR MANUAL J AND LOOK UNDRE MIN. & | | | MAX. VELOCITY, AND CORRECT DUCT SIZES. | | | EXAMPLE, AHU#2 SUPPLY DUCT IS 14" @ | | | 1,900 CFM'S THE VELOCITY IS 1,780. | | | MANUAL J STATES MAX. VELOCITY IS 1,100. | | | PLEASE CORRECT ALL SUPPLY AIR DUCTS | | | USING YOUR MANUAL J AS A REFERENCE. | | | | | | 4) REQUESTING FOR THE SECOND TIME, | | | RETURN AIR GRILL 30X18 TO AHU #1 IS TO | | | SMALL FOR A 5 TON UNIT, PLEASE CORRECT. | | | | | | 5) PLEASE SEE ATTACHED NOTICE (FS | | | 553.80(2)(B). | | | | | | 6) PLEASE CHECK WITH THE MANUFACTURE'S | | | SPECIFICATIONS ON COPPER LINE SIZES, 7/8 | | | APPEARS TO SMALL FOR A 5 TON SYSTEM. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-02-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-02-14 |
Time |
16:20 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2006-02-14 |
Time |
16:20 |
Sent To |
P |
|
| Notes |
| 2006-02-14 00:00:00 | *** DENIED *** | | | 1) PLEASE PROVIDE DETAILED MANUFACTURE'S | | | SPECIFICATION'S AND INSTALLATION | | | INSTRUCTIONS FOR GAS FIRE PLACE IN | | | LIBRARY. | | | | | | 2) PLEASE PROVIDE COMBUSTION AIR | | | CALCULATIONS FOR GAS FIRE PLACE IN | | | LIBRARY, PER 2004 FBC/R M1702. | | | | | | 3) PLEASSE SHOW ON MECHANICAL PLANS HOW | | | YOU ARE PROVIDING COMBUSTION AIR IN | | | LAUNDRY ROOM FOR GAS CLOTHES DRYER, AND | | | TANKLESS WATER HEATER, PER 2004 FBC/R | | | M1703. | | | | | | 4) NEED COMBUSTION AIR CALCULATIONS FOR | | | EACH GAS TANKLESS WATER HEATER, PER 2004 | | | FBC/RCH.17 . | | | | | | 5) MASTER BATHROOM NEEDS A EXHAUST FAN | | | BY THE TUB AREA (ON MECH. PLANS), PER | | | 2004 FBC/R M1506. | | | | | | 6) EXHAUST FAN IN LAUNDRY ROOM NEED TO | | | BE REMOVED FROM MECH. PLANS, PER 2004 | | | FBC/R M1701.2 . | | | | | | 7) RETURN AIR TRANSFER DUCTS IN THE | | | LIBRARY, AND STUDIO ARE TO SMALL, SEE | | | NOTE #8. | | | | | | 8)BALANCED RETURN AIR. | | | THIS MAY BE ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | (B)TRANSFER GRILLES SHALL USE 50 | | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | | CFM (OF SUPPLY AIR) FOR SIZING | | | THROUGH-THE-WALL TRANSFER GRILLES AND | | | USING AN UNRESTRICTED 1-INCH | | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | | RETURN AIR BALANCE | | | (C)HABITABLE ROOMS ONLY SHALL BE | | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | | PROPER BALANCED RETURN AIR EXCLUDING | | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | | AIR INTO THE MASTER SUITE SHALL BE | | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | | | 8) RETURN AIR GRILL 30X18 TO AHU #1 IS | | | TO SMALL FOR A 5 TON UNIT. | | | | | | 9) PLEASE SEE YELLOW HIGH LIGHTS ON DUCT | | | SIZES AS THEY ARE TO SMALL. REFER TO | | | YOUR MANUAL J AND LOOK UNDER MIN. & MAX. | | | VELOCITY, PLEASE CORRECT DUCT SIZES. | | | | | | 10) ENERGY CALCULATIONS AND MANUAL J ARE | | | DIFFICULT TO READ ALL PARTS. | | | CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY. PER 2004 FBC 106.1.1 | | | .PLEASE SUBMIT CLEARER COPYS. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-19 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2005-11-19 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2005-11-19 |
Time |
13:34 |
Sent To |
P |
|
| Notes |
| 2005-11-19 00:00:00 | ----------------DENIED------------------ | | | | | | 1. GAS DRYER IN LAUNDRY IS IN A CONFINED | | | SPACE PER 2004 FBC,R SEC.G2407.5.1. | | | COMBUSTION AIR MUST BE PROVIDED AS | | | PRESCRIBED IN SEC 2407.5.3 OR 2407.6. | | | | | | 2. PLAN CALLS FOR TWO GAS TANKLESS WATER | | | HEATERS, BOTH WITH INDOOR LOCATIONS. | | | PROVIDE MANUFACTURER'S | | | SPECS/INSTALLATION INSTRUCTIONS TO SHOW | | | THESE TO BE APPROVED FOR INDOOR | | | INSTALLATION OR REVISE PLAN TO SHOW | | | OUTDOOR INSTALLATION LOCATIONS. IF | | | TANKLESS WH IS TO REMAIN IN LAUNDRY | | | ROOM, BE SURE TO INCLUDE THE ADDITIONAL | | | BTUS IN THE CALCULATIONS FOR REQUIRED | | | COMBUSTION AIR. | | | | | | 3. IN MASTER BATH, THE REQUIRED EXHAUST | | | FAN IS LOCATED IN THE TOILET ROOM, | | | ISOLATING IT FROM THE REST OF THE MASTER | | | BATH. ARCHITECTUAL DRAWINGS DO NOT SHOW | | | A WINDOW IN THIS AREA TO ALLOW FOR AN | | | EXCEPTION TO THE BATH EXHAUST | | | REQUIREMENT.AN ADDITIONAL FAN IS | | | REQUIRED IN THE MAIN AREA OF THE MASTER | | | BATH. | | | | | | 4. PLAN CALLS FOR EXHAUST FAN IN LAUNDRY | | | ROOM.IS THIS FOR CODE COMPLIANCE | | | PURPOSES? THE CREATION OF NEGATIVE | | | PRESSURE IN THIS ROOM MAY ADVERSELY | | | EFFECT THE EFFICIENT COMBUSTION OF GAS | | | APPLIANCES AT THIS LOCATION. | | | | | | ANY QUESTIONS PLEASE CALL PATTY KRAUS AT | | | 561.805.6719 OR RON REGUEIRO AT | | | 561.805.6734 | | | | | | RONALD J REGUEIRO | | | 561.805.6734 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-12-12 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-12-12 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2007-12-12 14:32:46 | LETTER FROM ARCHITECT ADDRESSING INSPECTORS REQUEST FOR | | | AN OVERFLOW ROOF DRAIN OK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-04-14 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-04-14 |
Time |
07:16 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-02-21 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-02-21 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-02-21 |
Time |
09:36 |
Sent To |
B |
|
| Notes |
| 2006-02-21 00:00:00 | DENIED; | | | 1.RISER DIAGRAM DOES NOT FOLLOW FLOOR | | | PLAN. MASTER BATH AND BATH 2 ARE FLIPPED | | | ON RISER DIAGRAM. | | | 2.THE VENT FOR THE 1/2 BATH ON FIRST | | | FLOOR CANNOT BE THE RISER FOR THE | | | BATHROOM ON SECOND FLOOR. | | | 3.SHOW THE LAUNDRY TUB ABOVE THE WASHING | | | MACHINE A SANITARY CROSS IS NOT PERMITED | | | AND CLEANOUT SHOULD BE 48" ABOVE FINISH | | | FLOOR. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-22 |
Time |
16:27 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-11-22 |
Time |
16:27 |
Sent To |
B |
|
| Notes |
| 2005-11-22 00:00:00 | DENIED; | | | 1.TANKLESS GAS WATER HEATER TO BE | | | INSTALLED ON OUT SIDE NOT IN THE GARAGE. | | | 2.RISER DOES NOT REFECT THE FLOOR PLAN. | | | 3.POTTERY SINK NOT SHOWN ON RISER | | | DIAGRAM. | | | 4.KITCHEN SINK CANNOT DISCHARGE INTO THE | | | WET VENT OF A BATHROOM GROUP FBC-2004 | | | PLUMBING SECTION 909.1. KITCHEN SINK | | | CANNOT BE INSTALLED AS DRAWN. | | | 5.BAR SINK ON 2ND FLOOR REQUIRES A VENT | | | IF INSTALLED AS SHOWN ON RISER DIAGRAM. | | | SEC906.1 | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-09-14 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-09-14 |
Time |
11:07 |
Sent To |
PC |
|
| Notes |
| 2007-09-14 11:08:58 | ***APPROVED - REVISION - ADDING SITE WALL*** | | | | | | PROVISO:6' WALL NOT TO ENCROACH INTO FRONT SETBACK OF | | | 25' |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-19 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-19 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2007-07-19 15:57:29 | ***FAILED*** REVISION FOR SITE WALL | | | | | | | | | 1)NEEDS APPROVAL FROM HISTORIC PRESERVATION...5TH | | | FLOOR CITY HALL. | | | | | | 2)PLEASE PROVIDE AN EASEMENT CONSENT FORM FROM THE | | | CITY OF WEST PALM BEACH DEPARTMENT OF PUBLIC | | | UTILITIES...1ST FLOOR CITY HALL. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING | | | TECHNICIAN | | | (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-17 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-17 |
Time |
08:03 |
Sent To |
I |
|
| Notes |
| 2007-05-17 08:04:22 | PROVISO:REVISION FOR WINDOWS ONLY. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-02-14 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-02-14 |
Time |
11:11 |
Sent To |
|
|
| Notes |
| 2007-02-14 11:18:46 | ***REVISION FAILED*** | | | | | | 1) SURVEY SHALL BE PROVIDED INDICATING THE LOCATION OF | | | ALL IMPROVEMENTS AND THE NEW LOCATION FOR THE | | | GENERATOR, ETC.SETBACKS SHALL BE PROVIDED FROM THE | | | RELOCATED EQUIPMENT TO THE PROPERTY LINES. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-02-15 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-02-10 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-02-10 |
Time |
17:24 |
Sent To |
I |
|
| Notes |
| 2006-02-10 00:00:00 | NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF | | | LANDSCAPE WHICHEVER IS LESS WITHIN THE | | | FIRST 25FT FRONT SETBACK. | | | | | | NOTE: MUST PULL SEPERATE PERMIT FOR | | | FENCE/WALL/GATE WITH EASEMENT APPROVAL | | | FROM THE CITY OF WEST PALM BEACH. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | JACUZZI. | | | | | | PROVISO: NO 2/20 CONNECTION ALLOWED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-02 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-11-02 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-11-02 |
Time |
16:09 |
Sent To |
B |
|
| Notes |
| 2005-11-02 00:00:00 | DENIED, | | | 1. TOO MUCH CONCRETE WITHIN THE FIRST | | | 25FT FRONT SETBACK. | | | 2. MUST REDUCE THE WALKWAY TO 2.5FT OR | | | 2FT TO MEET THE ZONING REQUIREMENTS. | | | 3. 312.5SQ FT OF CONCRETE IS ALLOWED | | | WITHIN THE FIRST 25FT FRONT SETBACK. | | | | | | MUST MAINTAIN 1000SQ OR 75% WHICHEVER IS | | | LESS OF CONCRETE WITHIN THE FIRST 25FT | | | FRONT SETBACK. | | | | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | 805-6720 |
|
|