Plan Review Details - Permit 05100303
Plan Review Stops For Permit 05100303
Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2007-09-14 Cont ID  
Sent By lmartine Date 2007-09-14 Time 08:55 Rev Time 0.00
Received By lmartine Date 2007-09-14 Time 08:55 Sent To  
Notes
2007-09-14 08:56:08PRIVACY WALL AND GATE REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status P Date 2007-07-19 Cont ID  
Sent By lmartine Date 2007-07-19 Time 15:37 Rev Time 0.00
Received By choops Date 2007-07-19 Time 15:54 Sent To Z
Notes
2007-07-19 15:41:06REVISION FOR SITE WALLOK

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2007-06-07 Cont ID  
Sent By lmartine Date 2007-06-07 Time 11:54 Rev Time 0.00
Received By lmartine Date 2007-06-07 Time 11:54 Sent To  
Notes
2007-06-07 12:02:10REVISION FOR WINDOWS OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status P Date 2007-03-07 Cont ID  
Sent By lmartine Date 2007-03-07 Time 18:32 Rev Time 0.00
Received By lmartine Date 2007-03-07 Time 18:32 Sent To  
Notes
2007-03-07 18:33:17 
 SKYLIGHT REVISION

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-09-28 Cont ID  
Sent By alange Date 2006-09-28 Time 10:27 Rev Time 0.66
Received By alange Date 2006-09-28 Time 10:27 Sent To  
Notes
2006-09-28 00:00:00RESTAMPED PLANS OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-07-31 Cont ID  
Sent By alange Date 2006-07-31 Time 11:38 Rev Time 0.00
Received By alange Date 2006-07-31 Time 11:37 Sent To  
Notes
2006-07-31 00:00:00REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-04-20 Cont ID  
Sent By alange Date 2006-04-20 Time 09:26 Rev Time 1.50
Received By alange Date 2006-04-20 Time 09:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-03-27 Cont ID  
Sent By alange Date 2006-03-27 Time 13:37 Rev Time 0.75
Received By alange Date 2006-03-27 Time 13:04 Sent To  
Notes
2006-03-27 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 5. ALL QUALITY ASSURANCE IS NOW MISSING,
 (MIAMI-DADE) FOR EXAMPLE.
 TWO COPIES OF THESE SHOULD BE ATTACHED
 TO YOUR STATE PRODUCT APPROVALS.
 ALL PRODUCT APPROVALS SUBMITTED
 SHALL HAVE THE FOLLOWING STATE PRODUCT
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-02-23 Cont ID  
Sent By alange Date 2006-02-23 Time 15:40 Rev Time 1.50
Received By alange Date 2006-02-23 Time 14:04 Sent To  
Notes
2006-02-23 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
 SUBMIT ENERGY CALCS TO THE 2004 FBC
  
 5.ALL PRODUCT APPROVALS SUBMITTED
 SHALL HAVE THE FOLLOWING STATE PRODUCT
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-22 Cont ID  
Sent By alange Date 2005-12-22 Time 10:32 Rev Time 3.66
Received By alange Date 2005-12-22 Time 10:32 Sent To  
Notes
2005-12-22 00:00:00DENIED
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.SUBMIT ENERGY CALCS TO THE 2004 FBC
  
 4.SUBMIT PRODUCT APPROVALS FOR
 ROOFING, STRAPS AND TIE-DOWNS AND
 LINTELS.
  
 5.ALL PRODUCT APPROVALS SUBMITTED
 SHALL HAVE THE FOLLOWING STATE PRODUCT
 APPROVAL ATTACHED.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 6. SUBMIT A GUARDRAIL DETAIL SHOWING
 COMPLIANCE WITH R312.1
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-11-01 Cont ID  
Sent By btrobaug Date 2007-11-01 Time 09:25 Rev Time 0.00
Received By btrobaug Date 2007-11-01 Time 06:33 Sent To PC
Notes
2007-11-01 07:49:02 
  
  
  
 PROVISO
  
 PRIOR TO FINAL ELECTRICAL INSPECTION SUBMIT A SITE PLAN
 AND SURVEY INDICATING THE LOCATION OF THE GENERATOR NOW
 REMOVED FROM THE PLAN, SHEET E1. THIS LOCATION NEEDS TO
 HAVE A ZONING, ELECTRICAL, MECHANICAL AND BUILDING
 REVIEW FOR SETBACKS.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-02-16 Cont ID  
Sent By btrobaug Date 2007-02-16 Time 14:22 Rev Time 0.50
Received By btrobaug Date 2007-02-16 Time 13:58 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-04-11 Cont ID  
Sent By btrobaug Date 2006-04-11 Time 16:43 Rev Time 0.33
Received By btrobaug Date 2006-04-11 Time 16:37 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-03-24 Cont ID  
Sent By btrobaug Date 2006-03-23 Time 17:52 Rev Time 0.50
Received By btrobaug Date 2006-03-23 Time 17:20 Sent To B
Notes
2006-03-23 00:00:00 

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-02-14 Cont ID  
Sent By btrobaug Date 2006-02-14 Time 12:25 Rev Time 0.75
Received By btrobaug Date 2006-02-14 Time 11:04 Sent To M
Notes
2006-02-14 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE MANUFACTURERS
 SPECIFICATIONS FOR THE GENERATOR AND
 TRANSFER SWITCH.
  
 2} SMOKE DETECTORS ARE REQUIRED TO BE
 INSTALLED IN THE GAME ROOM ( SINCE IT IS
 COMPARTMENTED FROM THE REST OF THE UPPER
 FLOOR, AND THEREFORE OTHER DETECTORS)
 AND ON THE FIRST FLOOR. FBC RES. 313.1
  
 3} THE PANEL(A)INDICATES IT IS 400 AMP
 RATED, THE RISER INDICATES 200 AMPS.
 PLEASE CORRELATE.
  
 4} PLEASE CHECK AND CORRELATE THE A/C
 AND AHU LOADS WITH THE MECHANICAL PLAN.
 NOTE THE COMPRESSER LOADS ARE SHOWN
 LARGER THAN THE AHU LOADS.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-11-15 Cont ID  
Sent By btrobaug Date 2005-11-15 Time 12:18 Rev Time 1.50
Received By btrobaug Date 2005-11-15 Time 06:42 Sent To M
Notes
2005-11-15 00:00:00 
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE MANUFACTURERS
 SPECIFICATIONS FOR THE GENERATOR AND
 TRANSFER SWITCH.
  
 2} THE #5 BARE COPPER GEC IS NOT A AWG
 SIZE. GEC MUST BE A MINIMUM OF #1/0 PER
 250.66.
  
 3} THE GROUNDING ELECTRODE SYSTEM MUST
 COMPLY WITH 250.50. 250.52(A)(3)
 INDICATES HOW THE GEC MUST BE CONNECTED
 TO BUILDING (FOOTER) STEEL, PLEASE
 INDICATE SAME ON THE PLAN.
  
 4} INDICATE DISCONNECTING MEANS PER
 230.71. THE PANELS SHOWN ON THE RISER DO
 NOT SPECIFY MAIN BREAKERS.
  
 5} PLEASE SHOW THE LOCATION OF ALL
 SERVICE AND GENERATOR EQUIPMENT ON THE
 FLOOR PLAN. THE RISER SHOWS A GUTTER,
 THIS AND THE TRANSFER SWITCH ARE NOT
 LOCATED ON THE PLAN, AND PANELS ARE
 SHOWN INSIDE?
  
 6} PLEASE SIZE THE GUTTER SO THAT
 COMPLIANCE WITH ARTICLE 366 CAN BE
 DETERMINED.
  
 7} PLEASE NOTE THE GENERATOR MUST BE
 GROUNDED PER MANUFACTURERS SPEC'S.THIS
 IS NOT A SEPARATELY DERIVED SYSTEM AND
 MUST USE THE SERVICE NEUTRAL AND GROUND,
 THE GENERATOR NEUTRAL CANNOT BE BONDED
 TO THE FRAME AND THEN TO A ROD. THIS IS
 JUST A NOTE AS IT HAS BEEN BROUGHT TO MY
 ATTENTION BY CONTRACTORS THAT THESE
 MODELS HAVE A JUMPER FROM THE NEUTRAL TO
 THE FRAME, WHICH OF COURSE MUST BE
 REMOVED WHEN USING A TWO POLE SWITCH.
  
 8} REGARDING CIRCUIT A8, PLEASE SEE
 210.11(C)(3) 20 AMP.THAT CIRCUIT IS
 CONFINED TO A SINGLE BATHROOM OR TO ALL
 BATH GFI'S ONLY. THE GFI'S IN THE
 LAUNDRY MUST NOT BE ON THAT CIRCUIT.
 ALSO NOTE 1 GFI IN THE MASTER BATH IS ON
 B4.
  
 9} CIRCUIT #2, PANEL A, DINING ROOM
 RECEPTACLES MUST COMPLY WITH 210.5(B)(1)
 & (2), LIVING ROOM CANT BE ON THAT
 CIRCUIT.
  
 10} ALL OUTLETS, INCLUDING LIGHTING,
 RECEPTACLES, FANS AND SMOKE DETECTORS
 INSTALLED IN BEDROOMS MUST BE ARC FAULT
 PROTECTED PER 210.12. SEE DEFINITION OF
 "OUTLET" IN ARTICLE 100 FOR
 CLARIFICATION OF 210.12.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 18 Status N Date 2007-11-27 Cont ID  
Sent By adarroug Date 2007-11-27 Time 15:40 Rev Time 0.00
Received By adarroug Date 2007-11-27 Time 15:40 Sent To P
Notes
2007-11-27 15:40:19TO "P" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 17 Status N Date 2007-10-26 Cont ID  
Sent By adarroug Date 2007-10-26 Time 16:30 Rev Time 0.00
Received By adarroug Date 2007-10-26 Time 16:30 Sent To E
Notes
2007-10-26 16:31:17TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 16 Status N Date 2007-08-10 Cont ID  
Sent By dpalmer Date 2007-08-10 Time 09:38 Rev Time 0.00
Received By dpalmer Date 2007-08-10 Time 09:38 Sent To B
Notes
2007-08-10 09:39:47TO LM'S OFFICE

Review Stop I INCOMING/PROCESSING
Rev No 15 Status N Date 2007-06-24 Cont ID  
Sent By adarroug Date 2007-06-24 Time 13:19 Rev Time 0.00
Received By adarroug Date 2007-06-24 Time 13:19 Sent To B
Notes
2007-06-24 13:20:17TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 14 Status N Date 2007-05-15 Cont ID  
Sent By adarroug Date 2007-05-15 Time 09:25 Rev Time 0.00
Received By adarroug Date 2007-05-15 Time 09:25 Sent To HIST
Notes
2007-05-15 09:26:14TO "Z" BOX--TO BE ROUTED TO HISTORIC.--PER "LMARTINEZ"

Review Stop I INCOMING/PROCESSING
Rev No 13 Status N Date 2007-04-24 Cont ID  
Sent By adarroug Date 2007-04-24 Time 14:52 Rev Time 0.00
Received By adarroug Date 2007-04-24 Time 14:52 Sent To B
Notes
2007-04-24 14:53:05TO "LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 12 Status N Date 2007-03-15 Cont ID  
Sent By adarroug Date 2007-03-15 Time 11:31 Rev Time 0.00
Received By adarroug Date 2007-03-15 Time 11:31 Sent To M
Notes
2007-03-15 11:31:29TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 11 Status N Date 2007-02-28 Cont ID  
Sent By adarroug Date 2007-02-28 Time 14:20 Rev Time 0.00
Received By adarroug Date 2007-02-28 Time 14:20 Sent To M
Notes
2007-02-28 14:20:37TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-02-15 Cont ID  
Sent By adarroug Date 2007-02-15 Time 10:48 Rev Time 0.00
Received By adarroug Date 2007-02-15 Time 10:48 Sent To E
Notes
2007-02-15 10:49:17TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-02-09 Cont ID  
Sent By adarroug Date 2007-02-09 Time 09:44 Rev Time 0.00
Received By adarroug Date 2007-02-09 Time 09:44 Sent To Z
Notes
2007-02-09 09:44:27TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2006-09-09 Cont ID  
Sent By adarroug Date 2006-09-09 Time 18:54 Rev Time 0.00
Received By adarroug Date 2006-09-09 Time 18:54 Sent To B
Notes
2006-09-09 00:00:00TO "ALANGE" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-07-31 Cont ID  
Sent By adarroug Date 2006-07-31 Time 10:29 Rev Time 0.00
Received By adarroug Date 2006-07-31 Time 10:29 Sent To B
Notes
2006-07-31 00:00:00TO "ALANGE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-04-11 Cont ID  
Sent By adarroug Date 2006-04-11 Time 09:59 Rev Time 0.00
Received By adarroug Date 2006-04-11 Time 09:59 Sent To E
Notes
2006-04-11 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-03-16 Cont ID  
Sent By adarroug Date 2006-03-16 Time 09:53 Rev Time 0.00
Received By adarroug Date 2006-03-16 Time 09:53 Sent To E
Notes
2006-03-16 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-02-13 Cont ID  
Sent By mmclean Date 2006-02-15 Time 13:59 Rev Time 0.00
Received By adarroug Date 2006-02-13 Time 09:54 Sent To E
Notes
2006-02-13 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-02-07 Cont ID  
Sent By adarroug Date 2006-02-07 Time 14:33 Rev Time 0.00
Received By adarroug Date 2006-02-07 Time 14:33 Sent To Z
Notes
2006-02-07 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-11-10 Cont ID  
Sent By adarroug Date 2005-11-10 Time 11:51 Rev Time 0.00
Received By adarroug Date 2005-11-10 Time 11:51 Sent To E
Notes
2005-11-10 00:00:00TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-12-22 Cont ID  
Sent By alange Date 2005-12-22 Time 10:37 Rev Time 0.00
Received By alange Date 2005-10-11 Time 17:25 Sent To  
Notes
2005-10-11 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 7 Status P Date 2007-03-16 Cont ID  
Sent By tgordon Date 2007-03-16 Time 14:54 Rev Time 0.25
Received By tgordon Date 2007-03-16 Time 14:54 Sent To  
Notes
2007-03-16 14:55:19REVISION TO MECH. PLANS PAGE M-1.

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2007-03-01 Cont ID  
Sent By tgordon Date 2007-03-01 Time 09:27 Rev Time 0.30
Received By tgordon Date 2007-03-01 Time 09:27 Sent To  
Notes
2007-03-01 09:28:19REVISION TO MECH. PLANS PAGE M 1.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2007-02-20 Cont ID  
Sent By tgordon Date 2007-02-20 Time 10:56 Rev Time 0.45
Received By tgordon Date 2007-02-20 Time 10:56 Sent To  
Notes
2007-02-20 11:38:22** MECHANICAL REVISION **
 *** DENIED ***
 1) DUCT LAY-OUT IS DIFFICULT TO READ. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY. PER 2004 FBC
 106.1.1.
  
 2) RETURN AIR NEEDS TO BE PROVIDE FOR THE STUDIO AND
 LIBRARY, SEE 2004 FBC/R M1602.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
 .

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-04-12 Cont ID  
Sent By tgordon Date 2006-04-12 Time 09:59 Rev Time 0.00
Received By tgordon Date 2006-04-13 Time 07:57 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-03-24 Cont ID  
Sent By btrobaug Date 2006-03-24 Time 16:08 Rev Time 1.30
Received By tgordon Date 2006-03-24 Time 12:04 Sent To E
Notes
2006-03-24 00:00:00*** DENIED ***
 1) MANUFACTURE'S SPECIFICATION'S FOR THE
 GAS CLOTHES DRYER AND THE GAS FIRE PLACE
 SHOW NO DIRECT VENTING TO PROVIDE
 COMBUSTION AIR TO THE UNIT, THEY ONLY
 PROVIDE VENTING FOR EXHAUST.
  
 2) REQUESTING FOR THE SECOND TIME,
 PLEASE PROVIDE COMBUSTION AIR AND/OR
 COMB. AIR CALCULATIONS FOR THE GAS
 CLOTHES DRYER & GAS FIRE PLACE, PER 2004
 FBC/R M1703 .
  
 3) REQUESTING FOR THE SECOND TIME, REFER
 TO YOUR MANUAL J AND LOOK UNDRE MIN. &
 MAX. VELOCITY, AND CORRECT DUCT SIZES.
 EXAMPLE, AHU#2 SUPPLY DUCT IS 14" @
 1,900 CFM'S THE VELOCITY IS 1,780.
 MANUAL J STATES MAX. VELOCITY IS 1,100.
 PLEASE CORRECT ALL SUPPLY AIR DUCTS
 USING YOUR MANUAL J AS A REFERENCE.
  
 4) REQUESTING FOR THE SECOND TIME,
 RETURN AIR GRILL 30X18 TO AHU #1 IS TO
 SMALL FOR A 5 TON UNIT, PLEASE CORRECT.
  
 5) PLEASE SEE ATTACHED NOTICE (FS
 553.80(2)(B).
  
 6) PLEASE CHECK WITH THE MANUFACTURE'S
 SPECIFICATIONS ON COPPER LINE SIZES, 7/8
 APPEARS TO SMALL FOR A 5 TON SYSTEM.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-02-14 Cont ID  
Sent By tgordon Date 2006-02-14 Time 16:20 Rev Time 1.30
Received By tgordon Date 2006-02-14 Time 16:20 Sent To P
Notes
2006-02-14 00:00:00*** DENIED ***
 1) PLEASE PROVIDE DETAILED MANUFACTURE'S
 SPECIFICATION'S AND INSTALLATION
 INSTRUCTIONS FOR GAS FIRE PLACE IN
 LIBRARY.
  
 2) PLEASE PROVIDE COMBUSTION AIR
 CALCULATIONS FOR GAS FIRE PLACE IN
 LIBRARY, PER 2004 FBC/R M1702.
  
 3) PLEASSE SHOW ON MECHANICAL PLANS HOW
 YOU ARE PROVIDING COMBUSTION AIR IN
 LAUNDRY ROOM FOR GAS CLOTHES DRYER, AND
 TANKLESS WATER HEATER, PER 2004 FBC/R
 M1703.
  
 4) NEED COMBUSTION AIR CALCULATIONS FOR
 EACH GAS TANKLESS WATER HEATER, PER 2004
 FBC/RCH.17 .
  
 5) MASTER BATHROOM NEEDS A EXHAUST FAN
 BY THE TUB AREA (ON MECH. PLANS), PER
 2004 FBC/R M1506.
  
 6) EXHAUST FAN IN LAUNDRY ROOM NEED TO
 BE REMOVED FROM MECH. PLANS, PER 2004
 FBC/R M1701.2 .
  
 7) RETURN AIR TRANSFER DUCTS IN THE
 LIBRARY, AND STUDIO ARE TO SMALL, SEE
 NOTE #8.
  
 8)BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 8) RETURN AIR GRILL 30X18 TO AHU #1 IS
 TO SMALL FOR A 5 TON UNIT.
  
 9) PLEASE SEE YELLOW HIGH LIGHTS ON DUCT
 SIZES AS THEY ARE TO SMALL. REFER TO
 YOUR MANUAL J AND LOOK UNDER MIN. & MAX.
 VELOCITY, PLEASE CORRECT DUCT SIZES.
  
 10) ENERGY CALCULATIONS AND MANUAL J ARE
 DIFFICULT TO READ ALL PARTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY. PER 2004 FBC 106.1.1
 .PLEASE SUBMIT CLEARER COPYS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2005-11-19 Cont ID  
Sent By rregueir Date 2005-11-19 Time 15:06 Rev Time 0.00
Received By rregueir Date 2005-11-19 Time 13:34 Sent To P
Notes
2005-11-19 00:00:00----------------DENIED------------------
  
 1. GAS DRYER IN LAUNDRY IS IN A CONFINED
 SPACE PER 2004 FBC,R SEC.G2407.5.1.
 COMBUSTION AIR MUST BE PROVIDED AS
 PRESCRIBED IN SEC 2407.5.3 OR 2407.6.
  
 2. PLAN CALLS FOR TWO GAS TANKLESS WATER
 HEATERS, BOTH WITH INDOOR LOCATIONS.
 PROVIDE MANUFACTURER'S
 SPECS/INSTALLATION INSTRUCTIONS TO SHOW
 THESE TO BE APPROVED FOR INDOOR
 INSTALLATION OR REVISE PLAN TO SHOW
 OUTDOOR INSTALLATION LOCATIONS. IF
 TANKLESS WH IS TO REMAIN IN LAUNDRY
 ROOM, BE SURE TO INCLUDE THE ADDITIONAL
 BTUS IN THE CALCULATIONS FOR REQUIRED
 COMBUSTION AIR.
  
 3. IN MASTER BATH, THE REQUIRED EXHAUST
 FAN IS LOCATED IN THE TOILET ROOM,
 ISOLATING IT FROM THE REST OF THE MASTER
 BATH. ARCHITECTUAL DRAWINGS DO NOT SHOW
 A WINDOW IN THIS AREA TO ALLOW FOR AN
 EXCEPTION TO THE BATH EXHAUST
 REQUIREMENT.AN ADDITIONAL FAN IS
 REQUIRED IN THE MAIN AREA OF THE MASTER
 BATH.
  
 4. PLAN CALLS FOR EXHAUST FAN IN LAUNDRY
 ROOM.IS THIS FOR CODE COMPLIANCE
 PURPOSES? THE CREATION OF NEGATIVE
 PRESSURE IN THIS ROOM MAY ADVERSELY
 EFFECT THE EFFICIENT COMBUSTION OF GAS
 APPLIANCES AT THIS LOCATION.
  
 ANY QUESTIONS PLEASE CALL PATTY KRAUS AT
 561.805.6719 OR RON REGUEIRO AT
 561.805.6734
  
 RONALD J REGUEIRO
 561.805.6734
 [email protected]

Review Stop P PLUMBING
Rev No 4 Status P Date 2007-12-12 Cont ID  
Sent By jleech Date 2007-12-12 Time 14:30 Rev Time 0.00
Received By jleech Date 2007-12-12 Time 14:30 Sent To  
Notes
2007-12-12 14:32:46LETTER FROM ARCHITECT ADDRESSING INSPECTORS REQUEST FOR
 AN OVERFLOW ROOF DRAIN OK

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-04-14 Cont ID  
Sent By jleech Date 2006-04-14 Time 07:16 Rev Time 0.00
Received By jleech Date 2006-04-14 Time 07:16 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-02-21 Cont ID  
Sent By jleech Date 2006-02-21 Time 09:49 Rev Time 0.00
Received By jleech Date 2006-02-21 Time 09:36 Sent To B
Notes
2006-02-21 00:00:00DENIED;
 1.RISER DIAGRAM DOES NOT FOLLOW FLOOR
 PLAN. MASTER BATH AND BATH 2 ARE FLIPPED
 ON RISER DIAGRAM.
 2.THE VENT FOR THE 1/2 BATH ON FIRST
 FLOOR CANNOT BE THE RISER FOR THE
 BATHROOM ON SECOND FLOOR.
 3.SHOW THE LAUNDRY TUB ABOVE THE WASHING
 MACHINE A SANITARY CROSS IS NOT PERMITED
 AND CLEANOUT SHOULD BE 48" ABOVE FINISH
 FLOOR.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop P PLUMBING
Rev No 1 Status F Date 2005-11-22 Cont ID  
Sent By jleech Date 2005-11-22 Time 16:27 Rev Time 1.00
Received By jleech Date 2005-11-22 Time 16:27 Sent To B
Notes
2005-11-22 00:00:00DENIED;
 1.TANKLESS GAS WATER HEATER TO BE
 INSTALLED ON OUT SIDE NOT IN THE GARAGE.
 2.RISER DOES NOT REFECT THE FLOOR PLAN.
 3.POTTERY SINK NOT SHOWN ON RISER
 DIAGRAM.
 4.KITCHEN SINK CANNOT DISCHARGE INTO THE
 WET VENT OF A BATHROOM GROUP FBC-2004
 PLUMBING SECTION 909.1. KITCHEN SINK
 CANNOT BE INSTALLED AS DRAWN.
 5.BAR SINK ON 2ND FLOOR REQUIRES A VENT
 IF INSTALLED AS SHOWN ON RISER DIAGRAM.
 SEC906.1
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 6 Status P Date 2007-09-14 Cont ID  
Sent By choops Date 2007-09-14 Time 11:07 Rev Time 0.00
Received By choops Date 2007-09-14 Time 11:07 Sent To PC
Notes
2007-09-14 11:08:58***APPROVED - REVISION - ADDING SITE WALL***
  
 PROVISO:6' WALL NOT TO ENCROACH INTO FRONT SETBACK OF
 25'

Review Stop Z ZONING
Rev No 5 Status F Date 2007-07-19 Cont ID  
Sent By choops Date 2007-07-19 Time 15:55 Rev Time 0.00
Received By choops Date 2007-07-19 Time 15:55 Sent To  
Notes
2007-07-19 15:57:29***FAILED*** REVISION FOR SITE WALL
  
  
 1)NEEDS APPROVAL FROM HISTORIC PRESERVATION...5TH
 FLOOR CITY HALL.
  
 2)PLEASE PROVIDE AN EASEMENT CONSENT FORM FROM THE
 CITY OF WEST PALM BEACH DEPARTMENT OF PUBLIC
 UTILITIES...1ST FLOOR CITY HALL.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 4 Status P Date 2007-05-17 Cont ID  
Sent By choops Date 2007-05-17 Time 08:03 Rev Time 0.00
Received By choops Date 2007-05-17 Time 08:03 Sent To I
Notes
2007-05-17 08:04:22PROVISO:REVISION FOR WINDOWS ONLY.

Review Stop Z ZONING
Rev No 3 Status F Date 2007-02-14 Cont ID  
Sent By jroach Date 2007-02-14 Time 11:11 Rev Time 0.00
Received By jroach Date 2007-02-14 Time 11:11 Sent To  
Notes
2007-02-14 11:18:46***REVISION FAILED***
  
 1) SURVEY SHALL BE PROVIDED INDICATING THE LOCATION OF
 ALL IMPROVEMENTS AND THE NEW LOCATION FOR THE
 GENERATOR, ETC.SETBACKS SHALL BE PROVIDED FROM THE
 RELOCATED EQUIPMENT TO THE PROPERTY LINES.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER

Review Stop Z ZONING
Rev No 2 Status P Date 2006-02-15 Cont ID  
Sent By mmclean Date 2006-02-10 Time 17:25 Rev Time 0.00
Received By mmclean Date 2006-02-10 Time 17:24 Sent To I
Notes
2006-02-10 00:00:00NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 NOTE: MUST PULL SEPERATE PERMIT FOR
 FENCE/WALL/GATE WITH EASEMENT APPROVAL
 FROM THE CITY OF WEST PALM BEACH.
  
 NOTE: MUST PULL A SEPERATE PERMIT FOR
 JACUZZI.
  
 PROVISO: NO 2/20 CONNECTION ALLOWED.

Review Stop Z ZONING
Rev No 1 Status F Date 2005-11-02 Cont ID  
Sent By mmclean Date 2005-11-02 Time 16:09 Rev Time 0.00
Received By mmclean Date 2005-11-02 Time 16:09 Sent To B
Notes
2005-11-02 00:00:00DENIED,
 1. TOO MUCH CONCRETE WITHIN THE FIRST
 25FT FRONT SETBACK.
 2. MUST REDUCE THE WALKWAY TO 2.5FT OR
 2FT TO MEET THE ZONING REQUIREMENTS.
 3. 312.5SQ FT OF CONCRETE IS ALLOWED
 WITHIN THE FIRST 25FT FRONT SETBACK.
  
 MUST MAINTAIN 1000SQ OR 75% WHICHEVER IS
 LESS OF CONCRETE WITHIN THE FIRST 25FT
 FRONT SETBACK.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720