| Plan Review Stops For Permit 05100077 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-02-16 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-02-16 |
Time |
14:24 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-02-16 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2006-02-16 00:00:00 | REV FOR DOOR AND WALL DETAIL OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-27 |
Time |
10:37 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2005-12-27 |
Time |
10:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-02 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-02 |
Time |
12:40 |
Rev Time |
0.75 |
| Received By |
alange |
Date |
2005-12-02 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2005-12-02 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | A.ALL PAGES SHALL BE SIGNED AND SEAL | | | BY THE ARCHITECT OF RECORD. | | | | | | ANY QUESTIONS CALL ME | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-20 |
Time |
09:37 |
Rev Time |
2.25 |
| Received By |
alange |
Date |
2005-10-19 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2005-10-20 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.PLANS SHALL BE DESIGNED TO THE 2004 | | | FBC. | | | | | | 3.FBC 2004 EXISTING BUILDING 301.5 | | | A DESIGN PROFESSIONAL OR AN OWNER MUST | | | ELECT ONE OR A COMBINATION OF LEVELS OF | | | ALTERATION PURSUANT TO SECTIONS 303, 304 | | | AND 305 OF THIS CODE. | | | SHOW HOW COMPLIANCE WITH THE SELECTED | | | LEVEL WILL BE OBTAINED. | | | | | | 4.SHOW HOW RECEPTION COUNTER AND | | | KITCHEN SINK WILL COMPLY WITH FBC | | | CHAPTER 11 FOR ACCESSABILITY. | | | | | | 5. SAFTEY GLAZING REQUIRED AT INTERIOR | | | WINDOWS. FBC 2406.3 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2006-02-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-02-24 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-02-24 |
Time |
10:03 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-23 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-23 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2005-12-23 00:00:00 | **** REDLINED PLANS***** | | | | | | PLEASE SEE NEW REVISED E2-1 SHOWS | | | TRANSFORMER AND PANELS BEING RELOCATED | | | TO HALL WAY AND ABOVE CEILING, HOWEVER | | | PLEASE SEE E1.1 WAS NOT REVISED. | | | | | | PLEASE SEE GROUNDING ATTACHMENT LOCATION | | | FOR TRANSFORMER NOT SHOWN, MUST CONNECT | | | TO EXISTING GROUNDING ELECTRODE SYSTEM. | | | 250.30 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-07 |
Time |
07:56 |
Rev Time |
0.33 |
| Received By |
dpalmer |
Date |
2005-10-07 |
Time |
07:50 |
Sent To |
|
|
| Notes |
| 2005-10-07 00:00:00 | REDLINED | | | | | | 110.26 FOR MIN CLEARENCE IN NEW | | | ELECTRICAL CLOSET. IF USING SCALE ON | | | PLANS, CLEARENCE DOES NOT SEEM TO MET. | | | | | | REDLINED | | | | | | GROUNDING OF TRANSFORMER NOT INDICATED. | | | PLEASE SEE 250.30 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-02-17 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-02-17 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-02-17 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2006-02-17 00:00:00 | REVISION DATED 1/31/06 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-10-06 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-10-06 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-02-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-14 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-14 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2006-02-14 00:00:00 | TO "BOB"#8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-01-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-01-22 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-01-22 |
Time |
11:09 |
Sent To |
P |
|
| Notes |
| 2006-01-22 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-22 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-22 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | TO "BOB"#6 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-01 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-01 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2005-12-01 00:00:00 | TO "BOB"#14 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-20 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-20 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-10-04 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2005-10-04 00:00:00 | TO "COMM" BD#8 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-10-06 |
Time |
08:47 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-10-06 |
Time |
08:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-23 |
Time |
11:33 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-23 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-07 |
Time |
12:30 |
Rev Time |
0.50 |
| Received By |
jleech |
Date |
2005-12-07 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2005-12-07 00:00:00 | DENIED; | | | KITCHEN SINK DETAIL; | | | ACCESS PANEL MUST COMPLY WITH FBC CH. 11 | | | FIG.31 AND 32, COPY INCLOSED WITH | | | REVIEW. | | | COUNTER TO BE NO HIGHER THAN 34" AND | | | MUST HAVE A KNEE CLEARENCE OF AT LEAST | | | 27" HIGH. SINK CANNOT BE DEEPER THAN 6 | | | 1/2". SEC 11-4.24 COPY OF CODE WITH | | | REVIEW NOTES. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-10-07 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-07 |
Time |
09:17 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-10-07 |
Time |
09:17 |
Sent To |
|
|
| Notes |
| 2005-10-07 00:00:00 | DENIED; | | | 1.GENERAL NOTES; # 1 PLEASE CHANGE TO | | | FBC-2004. | | | 2.DEMESTIC WATER ISOMETRIC; WATER HAMMER | | | ARRESTORS TO BE USED FBC-2004 PLUMBING | | | SEC 604.9, TO BE INSTALLED AS CLOSE TO | | | SOURCE OF WATER HAMMER AS POSSIBLE. | | | 3.KITCHEN SINK SHALL COMPLY WITH FBC- | | | 2004 BUILDING CHAPTER 11 SEC. 11-4.24.1 | | | THRU 11-4.24.7. (SHOW DETAIL) | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|