| Plan Review Stops For Permit 05100073 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-25 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-25 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-25 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2007-05-25 13:50:52 | STRUCTURAL REVISION FOR BEAMS AND COLUMNSOKLM |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-07-06 |
Time |
16:42 |
Rev Time |
2.75 |
| Received By |
alange |
Date |
2006-07-06 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-09 |
Time |
08:17 |
Rev Time |
2.00 |
| Received By |
alange |
Date |
2006-05-09 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2006-05-09 00:00:00 | DENIED | | | | | | 3.ENGINEERS SEAL ON SOILS REPORT IS | | | NOT VALID.ENGINEERS SEALS USED AFTER | | | JANUARY 1, 2006 SHALL SHOW "LICENSED" | | | NOT "CERTIFICATE". 61G1-16.001 | | | | | | 5.PRODUCT APPROVALS; | | | A.PRODUCT APPROVALS REQUIRED FOR STRAPS | | | AND TIE-DOWNS. | | | B. CHECK STATE PRODUCT APPROVALS FOR | | | MULLIONS AND PGT EXTERIOR DOOR | | | SUBMITTED.STATE PRODUCT APPROVAL PAGES | | | ARE NOT THE CORRECT PAGES. WHEN | | | SEARCHING FOR STATE PRODUCT APPROVAL YOU | | | NEED TO GO ONE STEP FURTHER AND SELECT | | | THE PAGE SHOWING THE CATAGORY USED TO | | | COINSIDE WITH THE NOA SUBMITTED. | | | C.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | ART LANGE | | | BUILDING PLAN EXAMINER | | | 805-6672 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-21 |
Time |
12:13 |
Rev Time |
3.50 |
| Received By |
alange |
Date |
2005-12-21 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2005-12-21 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.SITE IS IN AN AREA OF QUESTIONABLE | | | SOILS.SUBMIT TWO ORIGONALS SOILS | | | REPORT WITH FOUNDATION RECOMMENDATIONS. | | | | | | 4.ALL PLANS SUBMITTED AFTER OCTOBER 1, | | | 2004 SHALL BE DESIGNED TO THE 2004 FBC. | | | | | | 5.PRODUCT APPROVALS; | | | A.PRODUCT APPROVALS REQUIRED FOR | | | OVERHEAD DOOR, LINTELS, FIXED WINDOW AND | | | STRAPS AND TIE-DOWNS. | | | B. STATE PRODUCT APPROVAL PAGES ARE NOT | | | THE CORRECT PAGES. WHEN SEARCHING FOR | | | STATE PRODUCT APPROVAL YOU NEED TO GO | | | ONE STEP FURTHER AND SELECT THE PAGE | | | SHOWING THE CATAGORY USED TO COINSIDE | | | WITH THE NOA SUBMITTED. | | | C.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 6.FIRST FLOOR WINDOW AND DOOR SCHEDULE | | | DOES NOT SHOW TYPE OF WINDOW USED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLAN EXAMINER | | | 805-6672 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-26 |
Time |
12:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-26 |
Time |
10:52 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2007-03-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-21 |
Time |
18:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-21 |
Time |
13:04 |
Sent To |
PC |
|
| Notes |
| 2007-03-21 18:15:28 | | | | ** UNSAT ** | | | | | | 1) NOTE:PLEASE CORRELATE RISER AND PANELS. PLEASE SEE | | | RISER SHOWS 3-3/0'S FOR THE FEEDERS TO THE JANDY PANEL, | | | WHEN THE SCHEDULE FOR THE JANDY PANEL AND THE JANDY | | | PANEL ITSELF SHOWS 3-#3'S. | | | PLEASE KNOW IF THIS IS INDEED 3/0'S THEN THE CONDUIT | | | SIZE OF 1 1/4 INCH IS TOO SMALL PER CHAPTER 9 TABLES | | | FOR CONDUIT FILL. | | | PLEASE ADJUST. | | | 408.4, 204.4, 310.16. FBC 106.1.2 | | | | | | 2) NOTE: PLEASE SEE NEW SCHEDULE FOR THE 400A MAIN | | | PANEL. PLEASE CLARIFY THE NUMBER OF CIRCUITS AND THIS | | | EQUIPMENT BEING SHOWN WITH MORE THAN 6 CIRCUITS AND | | | SPACES. PLEASE SEE 230.71 AS NO MORE THAN 6 SPACES IS | | | PERMITTED OR THIS EQUIPMENT MUST CONTAIN A MCB. (SHOWN | | | AS MLO). | | | | | | 3) NOTE: PLEASE SEE BOTH PANELS A AND B ARE BEING SHOWN | | | ON PANEL AS 42 CIRCUIT PANELS, HOWEVER ONLY PANEL *A* | | | IS SHOWN WITH 42 CIRCUITS, PANEL *B* SHOWS ONLY 40? | | | PLEASE CORRELATE. | | | FBC 106.1.2 | | | | | | 4) NOTE: PLEASE SEE 210.52B1, 210.11C1 AND 220.16 AS | | | ONE OR MORE OF THE CIRCUITS AS CONSIDERED IN 210.52B | | | ARE REQUIRED TO BE ON ONE OR MORE OF THE SMALL | | | APPLIANCE CIRCUITS. PLEASE SEE THAT EACH CIRCUIT OVER | | | SHALL BE SHOWN AND FIGURED AT 1500VA EACH. PLEASE SEE | | | PANEL *A* SEEMS TO SHOW A MINIMUM OF FOUR OF THESE | | | CIRCUITS, YET LOAD CALCULATIONS ONLY SHOW THREE | | | CIRCUITS AND LOADS FOR ONLY TWO? | | | PLEASE VERIFY HOW MANY OF THESE CIRCUITS ARE ACTUALLY | | | INSTALLED AND ADJUST ACCORDINGLY. | | | FBC 106.3.5.4 | | | | | | 5) NOTE: PLEASE SEE THE LOAD SHOWN FOR THE | | | REFRIGERATOR/FREEZER IN LOAD CALCULATIONS IS SHOWN AT | | | 1800VA WHICH EXCEEDS THAT OF THE 15AMP CIRCUIT | | | PROVIDED. | | | PLEASE VERIFY ACTUAL LOAD AND ADJUST ACCORDINGLY. | | | PLEASE KNOW IF THE LOAD IS NOT AS HIGH AS SHOWN, THE | | | CIRCUIT WOULD NOT NEED TO BE ADJUSTED. IF LOAD IS | | | INDEED THIS HIGH, PLEASE CHANGE TO A 20AMP CIRCUIT. | | | 240.4, 310.16 ETC. | | | | | | 6) NOTE: PLEASE CORRELATE THE LAUNDRY CIRCUIT FROM THE | | | LOAD CALCULATIONS AND THE PANEL SCHEDULE. PLEASE SEE | | | THE LOAD CALCULATIONS SHOW 1-POLE 30AMP CIRCUIT, YET | | | PANEL A SHOWS 1-POLE 20AMP CIRCUIT?? | | | FBC 106.1.2 | | | | | | 7) NOTE: PLEASE SEE THE BATHROOM DEDICATED GFI CIRCUITS | | | ARE NOTED ON PLANS AS 20AMP AND ARE ON PANEL SCHEDULES | | | AS 20AMP, HOWEVER PLEASE SEE THE LOAD CALCULATIONS | | | SCHEDULE WHICH SHOWS THESE AS 15AMPS CIRCUITS. THIS | | | SEEMS TO BE A MISPRINT. | | | 210.11C3, 210.52D. | | | FBC 106.1.2 | | | | | | 8) NOTE: PLEASE SEE THE LOAD CALCULATIONS WHICH | | | INDICATE A TOTAL OF 8-GEN LTS AND RECEPTS CIRCUITS WITH | | | A LOAD OF 13,923, WHICH PLACES A LOAD OF 14.503 AMPS ON | | | EACH OF THESE 15AMP RATED CIRCUITS. | | | PLEASE GO OVER LOADS BEING SHOWN ON THESE 15AMPS | | | CIRCUIT AND ADJUST. | | | FBC 106.3.5.4 | | | | | | ** PLEASE CALL TO GO OVER ANY OF THE COMMENTS IF NEED | | | BE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-02 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-01 |
Time |
17:56 |
Sent To |
PC |
|
| Notes |
| 2007-03-02 07:41:07 | *** UNSAT *** | | | | | | | | | | | | ** PLEASE SEE RISER HAS CHANGED FROM PREVIOUS PLANS AND | | | PLEASE SEE ITEMS WHICH WERE REDLINED FROM PREVIOUS | | | PLANS FROM 4/28/06 WHICH WERE NOT ADJUSTED AS MENTIONED | | | ON PLANS TO BE DONE BEFORE ROUGH. | | | | | | 1) NOTE: PLEASE SEE SERVICE HAS NOW COMPLETELY CHANGED | | | TO INCLUDE SERVICE AT 400AMPS HOWEVER GROUNDING | | | ELECTRODE CONDUCTOR WAS NOT INCREASED PER 250.66, | | | 310.15B6. (1/0) | | | | | | 2) NOTE: PLEASE PLANS STILL INDICATE A MAIN DISCONNECT | | | OUTSIDE WHERE RISER DOES NOT INCLUDE THIS. | | | PLEASE CORRELATE RISER AND PLANS. | | | PLEASE SEE LOAD CALCULATIONS ALSO CALL FOR A 300AMP | | | SERVICE AS SHOWN ON PREVIOUS PLANS HOWEVER PLANS NOW | | | SHOW 400AMP SERVICE. | | | PLEASE SEE THAT THE RISER NOW SHOWS PANEL *B* AS | | | 200AMPS WITH WHAT APPEARS TO BE 2-100AMP BREAKERS SHOWN | | | ON RISER?? IT IS UNCLEAR WHAT THIS IS? | | | PLEASE SEE THE SERVICE ENTRANCE CONDUCTORS OR FEEDERS | | | DEPENDING IF THERE IS A MAIN OUTSIDE ARE NOT RATED FOR | | | THE NEW 200AMP RATED MAIN. | | | PLEASE CORRELATE SEVERAL ITEMS ON PLANS AND RISER. | | | PLEASE SEE 310.15B6, 310.16, 240.4, 230.70 ETC FOR THE | | | MINIMUM REQUIRED FOR SERVICE, MAINS ETC. | | | | | | 3) NOTE: PLEASE VERIFY IF THERE IS NO MAINS OUTSIDE | | | THAT THE CONDUITS FROM METER TO PANELS ARE IN THE SLAB | | | AS REQUIRED PER 230.70, 230.71 | | | | | | 4) NOTE: PLEASE SEE NEW RECEPTACLE ADDED TO COUNTER | | | SPACE IN KITCHEN SHALL BE GFI/GFI PROTECTED PER | | | 210.8A6.(PLEASE SHOW). | | | | | | 5) NOTE: PLEASE KNOW THAT A MEETING WAS HELD AT THE | | | SOUTHERN SECTION MEETING IN OCT 06 WHERE WE WERE | | | DIRECTLY INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE | | | DETECTORS ON PLANS FOR RESIDENTIAL HOMES IS NOT | | | ACCEPTABLE WHEN THESE DEVICES ANY ACTUALLY FALL UNDER | | | THE DEFINITIONS OF SMOKE ALARMS WHICH WOULD BE SHOWN AS | | | SA/SMOKE ALARMS. | | | THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE | | | OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. BY | | | THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | | FOR OTHER NEW HOMES. | | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE*. | | | PLEASE SEE NFPA-72 11.5.1.1, 11.8.3 | | | | | | 6) NOTE: PLEASE KNOW THAT COMPLETE PANEL SCHEDULES | | | SHOWING ALL ROOMS AND AREAS IN WHICH CIRCUITS FEED WILL | | | BE REQUIRED FOR EACH PANEL. PLEASE SEE TEXT WHICH IS | | | TAKEN FROM COMMENTARY IN THE CODE WHICH STATES THE USE | | | OF *GEN LT* ETC IS NOT ACCEPTABLE. | | | | | | *CODE TO REQUIRE THAT THE IDENTIFICATION FOR EVERY | | | CIRCUIT SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE | | | LEGIBLE AND CLEARLY STATE THE SPECIFIC PURPOSE FOR | | | WHICH THE CIRCUIT IS USED. CIRCUITS USED FOR THE SAME | | | PURPOSE MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR | | | EXAMPLE, SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY | | | OUTLETS IN THE KITCHEN, DINING ROOM, AND KITCHEN | | | COUNTERTOPS. IDENTIFYING THE CIRCUITS AS SMALL | | | APPLIANCE BRANCH CIRCUITS IS NOT ACCEPTABLE; INSTEAD, | | | THEY SHOULD BE IDENTIFIED AS ``KITCHEN WALL | | | RECEPTACLES,'' ``DINING ROOM FLOOR RECEPTACLE,'' OR | | | ``KITCHEN COUNTERTOP RECEPTACLES LEFT OF SINK.'' | | | CIRCUIT DIRECTORIES CONTAINING MULTIPLE ENTRIES WITH | | | ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT PROVIDE THE | | | SUFFICIENT DETAIL REQUIRED BY THIS SECTION.* PLEASE | | | INCLUDE THESE IN TWO SEPARATE PANEL SCHEDULE(S) AND | | | DEPENDING ON RISER BASED ON NOTES ABOVE IT BEING | | | UNCLEAR WHAT THE TWO 100AMP BREAKERS ARE? | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.3.5.4 | | | | | | 7) NOTE: PLEASE SEE THE NOTES ON THE LOWER PART OF LOAD | | | CALCULATIONS WHICH STILL MENTIONS OUTSIDE WP LIGHTING | | | TO BE ON BATH CIRCUIT(S) WHICH IS NOT PERMITTED. THIS | | | WAS REDLINED ALSO ON PREVIOUS PLANS. | | | 210.52D, 210.11C3 | | | | | | * PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2006-04-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-04-28 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-04-28 |
Time |
14:53 |
Sent To |
M |
|
| Notes |
| 2006-04-28 00:00:00 | REDLINED ITEMS ON PLANS. | | | | | | | | | | | | 1) PLEASE SEE PLANS INDICATE A | | | DISCONNECT OUTSIDE WITH METER, HOWEVER | | | RISER SHOWS SLAB FEED TO MCB PANELS IN | | | GARAGE. ** WORK PER RISER NOTED ** | | | | | | 2) NOTE: PLEASE SEE NOTE MENTIONS FOR WP | | | LT FIXTURES TO BE CIRCUITED TO BATH | | | CIRCUIT? BATH CIRCUIT MAY NOT FEED | | | OUTDOOR LTS.* REDLINED** | | | | | | 3) MISSING LT FIXTURE IN EGRES HALL | | | UPSTAIRS. ** REDLINED ** | | | | | | | | | PLEASE REVISE THE ABOVE ALONG WIHT ANY | | | OTHER REVISIONS BEFORE ROUGH. IF NO | | | OTHER REVISIONS ARE MADE, THEN "REDLINED | | | PLANS" DO NOT NEED TO BE REVISED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-10-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-19 |
Time |
09:19 |
Rev Time |
2.00 |
| Received By |
dpalmer |
Date |
2005-10-18 |
Time |
13:25 |
Sent To |
M |
|
| Notes |
| 2005-10-19 00:00:00 | *********** UNSAT *********** | | | | | | | | | 1) NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | | | | 2)NOTE: PLEASE CORRELATE RISER DIAGRAM | | | AND PANEL SCHEDULES SUBMITTED. | | | PLEASE SEE RISER SHOWS WHAT APPEARS TO | | | BE A DISCONNECT LOCATED AT THE GROUNDING | | | ELECTRODE CONDUCTOR?? | | | PLEASE SEE A FEEDER/CONDUIT SEEMS TO | | | EXIT PANEL "A" AT TOP , BUT DOES NOT | | | SHOW OR INDICATE WHERE THIS GOES?? | | | PLEASE SEE THE SAME IS HOWN FOR PANEL | | | "B". | | | PLEASE SEE SEC'S DO NOT MEET MIN FOR | | | CODE COMPLIANCE PER 310.15B6, 240.4. | | | | | | | | | 3)NOTE: PLEASE SEE 250.66 FOR MIN GEC, | | | SHOWN AS #4. | | | | | | 4)NOTE: PLEASE SEE NOTE MENTIONS ALL | | | RECEPTS WITHIN 15' OF POOL TO BE GFI?? | | | PLEASE SEE 680.22 ETC, A MIN OF 20' | | | PLEASE ALSO SEE 680.22 FOR MIN DISTANCE | | | AND PROTECTION REQUIRED FOR ALL FIXTURES | | | WITH POOL AREA. PLEASE SEE LTS AS SHOWN | | | ON PLANS FOR SCONCE LOCATIONS AND FUTURE | | | POOL SHOWN. | | | | | | 5)NOTE: PLEASE CORRELATE NOTES ON PLANS | | | IN FOUR LOCATIONS FOR THE REQUIRED ARC | | | FAULT PROTECTION. | | | PLEASE SEE NOTE #6 MENTIONS THAT SD'S | | | "SHALL NOT" HAVE ARC FAULT PROTECTION?? | | | PLEASE SEE OTHER NOTES MENTIONS ONLY | | | RECEPTS AND OTHE NOTES MENTIONS ARC | | | FAULT REQUIRED??? | | | | | | ** PLEASE LIST ON THE PANEL SCHEDULE ALL | | | THE MIN REQUIRED ARC FAULT PROTECTED | | | CIRCUITS. PLEASE KNOW, UNDER THE 2002 | | | NEC 210.12 ALL OUTLETSIN BEDRMS ARE | | | REQUIRED TO HAVE ARC FAULT PROTECTION. | | | THIS IS LTS, FANS, SD'S AND RECEPTS. | | | | | | 6)NOTE: PLEASE 210.52 FOR RECEPTS | | | MISSING ON PLANS. PLEASE SEE MANY OF | | | THESE HAVE BEEN REDLINED AT LOCATIONS | | | MENTIONED. | | | | | | 7)NOTE: PLEASE SEE MISSING RECEPTS ALONG | | | KITCHEN COUNTERSPACE REQUIRED PER | | | 210.52C1 | | | | | | 8)NOTE: PLEASE SHOW ALL RECEPTS SERVING | | | KITCHEN COUNTERSPACE AS GFI/GFI | | | PROTECTED.,210.8A6 | | | | | | 9)NOTE: PLEASE SEE MISSING REQUIRED | | | EGRESS LT FIXTURES SHOWN AS "J" -BOXES | | | ON PLANS. PLEASE SEE 210.70, LS 101 7.8 | | | | | | 10)NOTE: PLEASE SEE MISSING FRONT GFI | | | RECEPT PER 210.52E, 210.8A | | | | | | 11)NOTE: PLEASE SEE MISSING SD REQUIRED | | | LEADING TO THE FLR ABOVE PER NFAP-72 | | | 11.5.1.1 | | | | | | PLEASE BE SURE TO ANY POSSIBLE COMMETNS | | | FROM OTHER REVIEWERS WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | | ONLY INSERT NEW REVISED SHEETS FOR | | | REVIEW AND STAMPING. | | | ON ECOPY OF ANY OLD/VOIDED SHEETS SHOULD | | | BE SUBMITTED FOR REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | NOTE, | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-05-02 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-02 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-02 |
Time |
11:42 |
Sent To |
B |
|
| Notes |
| 2007-05-02 11:42:46 | TO "LMARTINEZ" DESK/2 REV'S |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-20 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-20 |
Time |
10:06 |
Sent To |
E |
|
| Notes |
| 2007-03-20 10:07:15 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-02-22 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-02-22 |
Time |
17:20 |
Sent To |
E |
|
| Notes |
| 2007-02-22 17:21:33 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-23 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-23 |
Time |
15:29 |
Sent To |
B |
|
| Notes |
| 2006-06-23 00:00:00 | TO "ALANGE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-27 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-27 |
Time |
10:24 |
Sent To |
E |
|
| Notes |
| 2006-04-27 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-04-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-04-13 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-04-13 |
Time |
16:45 |
Sent To |
Z |
|
| Notes |
| 2006-04-13 00:00:00 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-10-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-10-18 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-18 |
Time |
09:49 |
Sent To |
E |
|
| Notes |
| 2005-10-18 00:00:00 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-12-21 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-21 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-10-04 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2005-10-04 00:00:00 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-05-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-01 |
Time |
10:28 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-05-01 |
Time |
10:28 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-11-14 |
Time |
08:22 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2005-11-14 |
Time |
08:22 |
Sent To |
P |
|
| Notes |
| 2005-11-14 00:00:00 | *** DENIED *** | | | 1) NEED DETAILED MANUFACTURE'S | | | SPECIFICATION'S ON FIREPLACE. | | | 2) NEED DETAILED MANUFACTURE'S | | | SPECIFICATION'S ON DOWN DRAFT RANGE. | | | 3) NEED NOTICE OF COMMENCEMENT. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2006-05-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2006-05-05 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2006-05-05 |
Time |
09:25 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-22 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-11-22 |
Time |
16:54 |
Rev Time |
1.00 |
| Received By |
jleech |
Date |
2005-11-22 |
Time |
16:54 |
Sent To |
B |
|
| Notes |
| 2005-11-22 00:00:00 | DENIED; | | | 1. VENT REQUIRED ON KITCHEN SINK AND W/W | | | DISCHARGE HOSE MUST BE INSTALLED BEFORE | | | THE KITCHEN SINK TRAP. | | | 2.W/M DRAIN TO BE 3"DRAIN, SEE FBC-2004 | | | PLUMBING SECTION 406.3. INSTALL CLEANOUT | | | FOR W/M AT 48" AFF. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-04-26 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2006-04-26 |
Time |
07:09 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2006-04-26 |
Time |
07:09 |
Sent To |
I |
|
| Notes |
| 2006-04-26 00:00:00 | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA/DECK/SCREEN ENCLOSURE. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/GATE WITH EASEMENT APPROVAL | | | FROM THE CITY OF WEST PALM UTILITY DEPT | | | AND FPL, FLORIDA PUBLIC UTILITIES, | | | ADELPHIA, BELLSOUTH FOR HE 5FT UTILITY | | | EASEMENT IN THE REAR OF PROPERTY. | | | | | | NOTE: CANNOT BUILD ANYTHING WITHIN THE | | | 5FT UTILITY EASEMENT. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-10-17 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-17 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-17 |
Time |
16:24 |
Sent To |
I |
|
| Notes |
| 2005-10-17 00:00:00 | DENIED, | | | 1. THE PROPOSED STRUCTURE IS OVER THE | | | HEIGHT REQUIREMENT OF 33FT (30FT PLUS | | | 10% FOR CHIMNEY, TOTAL OF 33FT). | | | | | | **************************************** | | | **************************************** | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | FENCE/WALL/COLUMNS WITH EASEMENT | | | APPROVAL FROM THE CITY OF WEST PALM | | | BEACH UTILITIES DEPT. | | | | | | NOTE: MUST PULL A SEPERATE PERMIT FOR | | | POOL/SPA/SCREEN ENCLOSURE/DECK. | | | | | | MICHELLE MCLEAN | | | ZONING TECHNICIAN | | | |
|
|