| Plan Review Stops For Permit 05100006 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2006-11-20 18:17:35 | "A" SHEETS NEEDS STAMPING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-10-26 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-10-26 |
Time |
11:30 |
Sent To |
|
|
| Notes |
| 2006-10-26 14:12:12 | ***PROVISOS*** | | | | | | 1.)A1, LANDING AT THE TOP OF THE RAMP IS TO BE | | | 60"MIN, FBC11-4.8.4.PLAN REDLINED. | | | | | | 2.)SEPARATE PERMIT REQUIRED FOR THE AWNING. | | | | | | 3.)SUBMIT THE ENERGY CALC WITH THE OWNER/AGENT LINE | | | SIGNED, FBC13-103.1. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-06-13 |
Time |
13:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2006-06-13 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2006-06-13 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | SECOND REVIEW | | | | | | COMMENTS FROM FIRST REVIEW: | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | PLEASE KEEP THE NOC PROVIDED IN THE | | | PERMIT APPLICATION PACKAGE. | | | | | | 2-7.)ADDRESSED. | | | | | | 8.)PROVIDE CERTIFICATION IN REGARDS TO | | | THE FLOOR LOADING, SECOND FLOOR.SHOW | | | COMPLIANCE WITH FBC TABLE 1607.1. | | | | | | 3RD REVIEW - THE NEW NOTE REFERS TO "IN | | | ACCORANCE WITH SBC TABLE".WRONG CODE; | | | NO TABLE REFERENCED. | | | | | | 9. - 10)ADDRESSED. | | | | | | 11.)VERTICAL ACCESSIBILITY REQUIRED, | | | FBC EB 806, FBC11-4.1.6(1)(B). | | | | | | ADDRESSED, BUT PLEASE SHOW SIGNAGE | | | REQUIRED BY FBC11-4.10.5. | | | | | | 3RD REVIEW - PROVIDE SIGNAGE | | | INFORMATION.A CODE REFERENCE WAS | | | PROVIDED, BUT NO DETAIL OR SPECIFICATION | | | PROVIDED. | | | | | | 12-27.)PRODUCT APPROVALS ARE TO BE | | | REVIEWED BY DESIGNER OF RECORD, | | | FBC*106.3.3. | | | | | | NO PRODUCT APPROVALS SUBMITTED.PLEASE | | | HAVE REVIEWED BY DOR AND SUBMIT. | | | | | | CODE COMPLIANCE CANNOT BE DETERMINED | | | UNTIL DESIGN PRESSURE ISSUES RESOLVED. | | | PRODUCT APPROVALS ARE TO BE REVIEWED BY | | | DESIGNER OF RECORD, NOT ADDRESSED. | | | | | | NEW COMMENTS: | | | | | | 28-31.) ADDRESSED. | | | | | | 32.)SEE ATTACHED FS553(80)(2)(B).A | | | 4X PLAN REVIEW FEE IS REQUIRED TO BE | | | CHARGED IF COMMENTS NOT PROPERLY | | | ADDRESSED A THIRD TIME. | | | | | | 3RD REVIEW - 4X FEE CHARGED.NOTE THAT | | | THIS FEE WILL BE CHARGED EVERY TIME IF | | | COMMENTS NOT ADDRESSED. | | | | | | 33.)THE HANDWRITTEN NUMBER FOR THE | | | REVIEION TO THE AREA CALCS IS NOT THE | | | SAME ON ALL SHEETS.ARE THERE OTHER | | | DISCRPEANCIES? | | | | | | 34.)CHANGES HANDWRITTEN TO THE PLAN | | | ARE TO BE INITIALLED. | | | | | | 35.)REMOVE OLD DATA FROM THE PLAN. | | | THE OLD "DESIGN DATA" IS STILL ON THE | | | PLAN WITH A CLOUD THAT STATES "DELETE". | | | DELETE FROM THE PLAN.A NEW ONE HAS | | | BEEN PASTED.INCORPORATE PROPERLY INTO | | | THE SHEET.THIS IS NOT AN ACCEPTABLE | | | WAY TO CHANGE A SEALED DRAWING AS THERE | | | IS NO WAY TO TELL WHO MADE THIS CHANGE, | | | AFTER THE SHEET WAS SIGNED AND SEALED. | | | | | | 36.)BUILDING TYPE SHOULD INDICATE TYPE | | | A OR B, FBC6. | | | | | | 37.)HOW HAVE YOU DETERMINED DESIGN | | | PRESSURES?SOME ARE THE SAME AS TABLE | | | 1609.6 FBC, BUT THIS BUILDING IS OVER | | | 30'.LARGER OPENINGS ON THE FIRST FLOOR | | | HAVE DPS HIGHER THAN SMALLER OPENINGS. | | | | | | 38.)INCORRECT CODE ON ENERGY CALCS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2006-03-22 |
Time |
11:38 |
Rev Time |
4.00 |
| Received By |
shill |
Date |
2006-03-20 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2006-03-22 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | SECOND REVIEW | | | | | | COMMENTS FROM FIRST REVIEW: | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | PLEASE KEEP THE NOC PROVIDED IN THE | | | PERMIT APPLICATION PACKAGE. | | | | | | 2.)PLEASE ADJUST THE VALUE ON THE | | | PERMIT APPLICATION.I UNDERSTAND THAT | | | THIS AMOUNT IS FOR THE DEMOLITION ONLY, | | | WHICH WILL BE ON A SEPARATE PERMIT. | | | | | | NOT ADDRESSED. | | | | | | 3. - 7.)ADDRESSED. | | | | | | 8.)PROVIDE CERTIFICATION IN REGARDS TO | | | THE FLOOR LOADING, SECOND FLOOR.SHOW | | | COMPLIANCE WITH FBC TABLE 1607.1. | | | | | | THE NOTE DOES NOT INDICATE THAT THIS IS | | | A FLOOR CERTIFICATION.IT APPEARS TO BE | | | THE DESIGN CRITERIA.AS IT IS EXISTING, | | | DESIGN CRITERIA DOES NOT SHOW | | | COMPLIANCE. | | | | | | 9. ? 10)ADDRESSED. | | | | | | 11.)VERTICAL ACCESSIBILITY REQUIRED, | | | FBC EB 806, FBC11-4.1.6(1)(B). | | | | | | ADDRESSED, BUT PLEASE SHOW SIGNAGE | | | REQUIRED BY FBC11-4.10.5. | | | | | | 12.)THE WEST END OF THE MEZZANINE HAS | | | A 6IN STEP.SEE FBC11-4.1(1)(A).AN | | | ACCESSIBLE ROUTE SHALL CONNECT | | | ACCESSIBLE ELEMENTS AND SPACES, | | | FBC11-4.1.2(2). | | | | | | A CONCRETE RAMP IS NOW SHOWN.INDICATE | | | ON THE PLAN WHAT THE ADDITIONAL LOAD IS | | | AND CONFIRM THAT THE EXISTING CONDITIONS | | | CAN ACCOMDATE THE ADDITIONAL DEAD LOAD. | | | | | | SHOW RAMP WIDTH, BOTH RAMPS, | | | FBC11-4.8.3. | | | | | | 13-16.)ADDRESSED. | | | | | | 17.)PROVIDE A FIRE SPRINKLER | | | SCHEMATIC, FBC*106.3.5.1.1(5). | | | | | | THIS WAS PROVIDED.CLARIFY AS TO WHY | | | THERE ARE NOT SPRINKLER HEADS, FIRST | | | FLOOR, IN THE ENTRY AREA AND CENTER. | | | ALSO CLARIFY AS TO HOW THE SPRINKLER | | | HEADS SECOND FLOOR, 28FT ABOVE FINISH | | | FLOOR, IN THE OPEN AREA WILL BE | | | EFFFECTIVE. | | | | | | 18-19.)ADDRESSED. | | | | | | 20.)ADDRESSED. | | | | | | 21.)PROVIDE DETAILS FOR THE EXISTING | | | STAIRS AND HANDRAILS.SHOW COMPLIANCE | | | WITH FBC1009, FBC11-4.9. | | | | | | RESPONSE LETTER STATES THAT THERE ARE | | | TWO EXITS.ONLY ONE SHOWN ON THE LIFE | | | SAFETY PLAN FOR BOTH THE FIRST FLOOR AND | | | THE SECOND FLOOR.EXIT LIGHTS SHOULD BE | | | SHOWN AT ALL EXITS.THE TWO EXITS ARE | | | TO BE REMOTELY LOCATED FBC104.2.1(2). | | | THE DISTANCE BETWEEN THE TWO STAIRS, | | | SECOND FLOOR DO NOT APPEAR TO BE ONE | | | THIRD DISTANCE APART.INDICATE ON THE | | | PLAN THAT BOTH EXITS ARE ACCESSIBLE | | | (SHOW ELEVATION CHANGE AT DOORWAYS). | | | | | | REVISE THE LIFE SAFETY PLAN AND ELECTRIC | | | PLAN TO CLEARLY SHOW TWO EXITS WHICH DO | | | NOT EXCEED TRAVEL DISTANCE OR COMMON | | | PATH OF TRAVEL. | | | | | | DETAIL 3A7, THE STAIR RAIL ALSO SERVES | | | AS A GUARDRAIL.THE HEIGHT IS TO COMPLY | | | WITH FBC1012.2. | | | | | | 22.)SHOW REQUIRED TENANT SEPARATION ON | | | THE EXISTING WALLS, FBC708. | | | | | | NO SEPARATION SHOWN BETWEEN BLDG ELEC | | | AND THE RENOVATED SPACE. | | | | | | SHOW CONTINUITY REQUIRED BY FBC708.4. | | | | | | 23-26.)ADDRESSED. | | | | | | 27.)PRODUCT APPROVALS ARE TO BE | | | REVIEWED BY DESIGNER OF RECORD, | | | FBC*106.3.3. | | | | | | NO PRODUCT APPROVALS SUBMITTED.PLEASE | | | HAVE REVIEWED BY DOR AND SUBMIT. | | | | | | NEW COMMENTS: | | | | | | 28.)ELEVATOR IS TO CONFORM TO | | | ASME17.1, FBC30.NOTE THE REQUIREMENT | | | ON THE PLAN. | | | | | | 29.)PROVIDE ELEVATOR SIGNAGE | | | FBC3002.3. | | | | | | 30.)DECLARE OCCUPANCY OF ADJACENT | | | SPACES, INCLUDING THE THIRD FLOOR.SEE | | | FBC TABLE 302.3.2.SHOW OCCUPANCY | | | SEPARATION OR TENANT SEPARATION AND | | | CONTINUITY FBC706.4. | | | | | | 31.)FBC1019.1.5, STORAGE IS SHOWN | | | UNDER STAIR 2.SHOW REQUIRED FIRE | | | PROTECTION AND SPRINKLER. | | | | | | 32.)SEE ATTACHED FS553(80)(2)(B).A | | | 4X PLAN REVIEW FEE IS REQUIRED TO BE | | | CHARGED IF COMMENTS NOT PROPERLY | | | ADDRESSED A THIRD TIME. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-20 |
Time |
11:10 |
Rev Time |
6.00 |
| Received By |
shill |
Date |
2005-12-12 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2005-12-20 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | | FILED WITH THE CLERK OF COURTS BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2.)PLEASE ADJUST THE VALUE ON THE | | | PERMIT APPLICATION.I UNDERSTAND THAT | | | THIS AMOUNT IS FOR THE DEMOLITION ONLY, | | | WHICH WILL BE ON A SEPARATE PERMIT. | | | | | | 3.)THE ENERGY CALCS STATE THAT THE | | | AREA IS 6708, SHEET COV IS 6762. | | | | | | 4.)ALTHOUGH THE PLANS REFER TO THE | | | SECOND STORY AS A MEZZANINE, IT IS NOT A | | | MEZZANINE BY DEFINITION, FBC502.1. | | | | | | 5.)COV, GENERAL NOTE #2 REFERS TO | | | FBC2001.GOVERNING CODE IS FBC2004 | | | EFFECTIVE OCTOBER 1, 2005. | | | | | | 6.)PROVIDE TOTAL AREA OF THE BUILDING, | | | FBC EB CODE CHAPTER 3. | | | | | | 7.)A CHANGE OF OCCUPANCY IS TO COMPLY | | | WITH FBC EB CHAPTERS 5 THROUGH 7, FBC EB | | | 812.1.2. | | | | | | 8.)PROVIDE CERTIFICATION IN REGARDS TO | | | THE FLOOR LOADING, SECOND FLOOR.SHOW | | | COMPLIANCE WITH FBC TABLE 1607.1. | | | | | | 9.)SEE ATTACHED POLICY, ITEMS 13 AND | | | 14, IN REGARDS TO IMPACT PROTECTION. | | | USE OF REMOVABLE SHUTTERS ON THE SECOND | | | FLOOR OF COMMERCIAL BUILDINGS IS | | | PROHIBITED.USE OF REMOVABLE SHUTTERS | | | ON THE FIRST FLOOR REQUIRES APPROVAL BY | | | THE BUILDING OFFICIAL. | | | | | | 10.)THERE IS NO ACCESS TO THE TOILET | | | VESTIBULE.ADDRESS. | | | | | | 11.)VERTICAL ACCESSIBILITY REQUIRED, | | | FBC EB 806, FBC11-4.1.6(1)(B). | | | | | | 12.)THE WEST END OF THE MEZZANINE HAS | | | A 6IN STEP.SEE FBC11-4.1(1)(A).AN | | | ACCESSIBLE ROUTE SHALL CONNECT | | | ACCESSIBLE ELEMENTS AND SPACES, | | | FBC11-4.1.2(2). | | | | | | 13.)WHAT WAS LOCATED IN THE AREA | | | MARKED ?VOID? ON THE PLAN? | | | | | | 14.)SHOW THE PROPERTY LINE ON THE | | | PLAN, OR PROVIDE A SITE PLAN.THE | | | EXTERIOR STAIR DOOR SHALL NOT OPEN INTO | | | THE PUBLIC RIGHT-OF-WAY.SEE FBC EB | | | 812.1.2, FBC EB 605, FBC3202.2. | | | | | | 15.)THE AWNING IS TO COMPLY WITH | | | FBC3202.3.1.SHOW COMPLIANCE ON THE | | | PLAN. | | | | | | 16.)DOES THE ELEVATOR OPEN INTO A | | | COMMON AREA? | | | | | | 17.)PROVIDE A FIRE SPRINKLER | | | SCHEMATIC, FBC*106.3.5.1.1(5). | | | | | | 18.)SPECIFY INTERIOR FINISH | | | CLASSIFICATION FBC803. | | | | | | 19.)SPECIFY WALL FINISH IN THE | | | BATHROOMS, FBC1210.2. | | | | | | 20.)PROVIDE A ROOM DESIGNATION, | | | MEZZANINE WEST, AT DOOR 21.IF THIS IS | | | STORAGE PROVIDE INFORMATION AS TO WHAT | | | WILL BE STORED THERE AND AREA | | | CALCULATION, SEE FBC302.3.2, FBC309. | | | | | | 21.)PROVIDE DETAILS FOR THE EXISTING | | | STAIRS AND HANDRAILS.SHOW COMPLIANCE | | | WITH FBC1009, FBC11-4.9. | | | | | | 22.)SHOW REQUIRED TENANT SEPARATION ON | | | THE EXISTING WALLS, FBC708. | | | | | | 23.)SHOW MANEUVERING CLEARANCE, PULL | | | SIDE, FOR DOORS 21, 15, FBC11-4.13.6, | | | FIGURE 11-25. | | | | | | 24.)THE ACCESSIBLE WATER CLOSET SHALL | | | BE LOCATED IN THE CORNER, DIAGONAL TO | | | THE DOOR, FBC11-4.17.3 EXCEPTION (2). | | | | | | 25.)PROVIDE A DETAIL FOR PENETRATIONS | | | THROUGH THE TENANT SPACES ABOVE. | | | | | | 26.)PROVIDE A MINIMUM CLEARANCE FOR | | | THE CONDENSING UNIT, M2, FBC TABLE | | | 1509.7. | | | | | | 27.)PRODUCT APPROVALS ARE TO BE | | | REVIEWED BY DESIGNER OF RECORD, | | | FBC*106.3.3. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-11-20 |
Time |
18:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-11-20 |
Time |
17:56 |
Sent To |
B |
|
| Notes |
| 2006-11-20 18:17:08 | ELECTRICAL PLANS STAMPED. | | | SENT TO BLUIDING AS "A" SHEETS NEED STAMPING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-10-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-10-27 |
Time |
07:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-10-27 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2006-10-27 07:46:58 | ***UNSAT 4TH REVIEW *** | | | | | | 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS REVIEW. PLEASE | | | SEE FBC CHAPTER 13, 13-415.1.1, .1.2 AND .1.3. | | | PLEASE SEE AS PREVIOUSLY NOTED, MULTIPLE FOORS AND | | | AREAS AND REQUIREMENTS FOR OVER RIDES DEVICES. PLEASE | | | KNOW THIS WAS GONE OVER IN MEETING AND ONE ITEM | | | MENTIONED WAS GOING TO BE THATOCC SENSORS WERE GOING | | | TO BE ADDEDTO SECOND FLR FOR OVER RIDE CONTROL??? | | | PLEASE KNOW, IF AN OCCUPANT IS ON THE 2ND FLR AND TIME | | | EXPIRES ON SYSTEM SCHEDULEING, THE OCCUPANT MUST BE | | | ABLE TO OVER RIDE SYSTEM. THIS CAN BE DONE IN MULTIPLE | | | WAYS, HOWEVER THE ONLY DEVICE SHOWN IS THE ONE LOCATED | | | AT THE FRONT DOOR?? | | | PLEASE SEE ALL OTHER AREAS /ROOMS CONTAING FLOOR TO | | | CEILING HEIGHT PARTITIONS SHALL ALSO CONTAIN OVER RIDE | | | DEVICES, WHETHER OCC SENSOR TYPE OR TIME TYPE. | | | PLEASE SEE IF USING OS TYPE , PLEASE LIST ON SYMBOL | | | LEGEND THE MAX TIMES PERMITTED. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-06-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-06-09 |
Time |
20:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-06-09 |
Time |
19:38 |
Sent To |
|
|
| Notes |
| 2006-06-09 00:00:00 | *********** UNSAT 3RD REVIEW ********* | | | | | | ** PLEASE SEE SOME COMMENTS FROM | | | PREVIOUS REVIEWS AND SOME NEW COMMENTS | | | DUE TO THE PLANS BEING SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE AS REQUESTED ON THE | | | TWO PREVIOUS REVIEWS, PHOTO-METRICS ARE | | | TO BE PROVIDED WHICH MEET THE MINIMUM | | | REQUIREMENTS AS SET FORTH IN THE 2003 | | | NFPA-101 LIFE SAFETY CODE. | | | PLEASE SEE THE RESPONSE MENTIONED THAT | | | THIS HAD BEEN ACHIEVED ON BOTH SETS | | | SUBMITED, HOWEVER AS STATED ON PREVIOUS | | | REVIEWS: 7.8.1.3 UNDER NORMAL | | | CONDITIONS, THE LIGHTING LEVELS ARE TO | | | BE 10FT CANDLES MIN(AVG)(108 LUX)AND | | | ONLY UNDER EMERGENCY CONDITIONS CAN THE | | | LIGHTING LEVELS BE REDUCED TO 1FT CANDLE | | | AVG MIN (10.8LUX). PLEASE SEE STAIR | | | LOCATIONS DO NOT SHOW THIS. | | | PLEASE SEE THIS IS NOT SHOWN ON PLANS. | | | PLEASE SEE ON PREVIOUS REVIEW IT WAS | | | REQUESTED THE PERSON RESPONSIBLE FOR | | | LIGHTING DESIGN/PHOTO-METRICS WHICH IS | | | THE ENGINEER OF RECORD SHALL SIGN,DATE | | | AND SEAL PLANS. | | | PLEASE SEE LIGHTING DESIGN IS NOW SHOWN | | | BY ANOTHER PERSON WHICH IS NOT SIGNED | | | PER FBC 104.2.1,106.3 ADMINISTRATIVE | | | SEC. | | | | | | 2) NOTE: PLEASE SEE PREVIOUS NOTE FOR | | | THE 2004 FBC CHAPTER 13. | | | 13-415.1.ABC.1.1, .1.2, .1.3 ETC. | | | PLEASE SEE A TIME CLOCK IS MENTIONED IN | | | RESPONSE HOWEVER THIS IS NOT THE ONLY | | | ITEM REQUIRED. | | | PLEASE SEE MULTIPLE FLOORS, OVER RIDES, | | | LOCATIONS, SCHEDULING ETC COULD NOT BE | | | LOCATED. | | | PLEASE SEE MORE THAN ONE SYSTEM IS | | | REQUIRED WHEN MORE THAN ONE FLOOR IS IN | | | SCOPE ETC. | | | PLEASE SEE ENERGY CALCS SUBMITTED | | | INDICATE THE 2001 FBC?, YET PLANS ARE TO | | | BE UNDER THE 2004 FBC. PLEASE SEE | | | 13-415.1.AB.1 AND PRESCRIPTIVE METHODS | | | WHICH MUST BE DONE FOR RENOVATIONS. "C". | | | | | | 3) NOTE: PLEASE SEE VALUATION FOR SCOPE | | | OF WORK HAS STILL NOT BEEN ADJUSTED. | | | PLEASE SEE FBC ADMINISTRATIVE SECTION AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH | | | 108.3. COMPLETE SCOPE PF WORK SHALL | | | INCLUDE ALL LABOR AND MATERIALS. | | | PLEASE SEE THE FOLLOWING COMMENT AS THE | | | FEES WILL BE AFFECTED. | | | | | | 4) NOTE: PLEASE SEE A NOTICE WAS GIVEN | | | ON PREVIOUS REVIEW WITH REFERENCE TO THE | | | FS 553.80(2)(B) WITH RESPECT TO REPEAT | | | COMMENTS THREE OR MORE TIMES. | | | PLEASE SEE A 4X FEE FOR THE PLAN REVIEW | | | PORTION OF THE EMIT FEE HAS NOW BEEN | | | ASSESSED AND SHALL BE PAID BEFORE | | | RE-SUBMITTING PLANS FOR THE NEXT REVIEW. | | | PLEASE KNOW THE VALUE FOR SCOPE OF WORK | | | WILL BE ASSESSED BY THIS DEPARTMENT | | | WHICH WILL AFFECT THIS FINE. | | | | | | ** | | | NEW NOTES; | | | | | | 5) NOTE: PLEASE SEE PLANS NOW PLANS ARE | | | BEING SUBMITTED DONE BY AN ENGINEER AND ENGINEERING | | | FIRM. | | | PLEASE SEE FLORIDA ADMINISTRATIVE CODE 61G15-23.002 | | | WHICH REQUIRES THE PRINTED | | | NAME AND LICENSE NUMBER OF SAID ENGINEER | | | ON TITLE BLOCKS. THIS SAME SECTION ALSO | | | REQUIRES A CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR SAID ENGINEERING FIRM AS | | | REQUIRED PER FS 471.023 | | | | | | 6) NOTE: PLEASE SEE ELECTRICAL PLANS | | | ALSO CONTAIN A "STAMP" FOR THE SIGNATURE | | | OF THE SAID ENGINEER WHICH UNDER FS | | | 471.025, FAC 61G15-23.002 IS REQUIRED TO | | | BE ORIGINAL SIGNATURE AND DATED. | | | PLEASE SEE ONLY THE DATE IS IN ORIGINAL | | | "WET" INK. | | | PLEASE KNOW, STAMPS FOR SIGNATURES ARE | | | NOT PERMITTED UNDER FS/ FAC. | | | PLEASE ALSO KNOW, BOTH SETS OF | | | ELECTRICAL PLANS AND ORIGINAL ELECTRICAL | | | PLANS DONE BY THE ARCHITECT ARE ALL | | | BEING RETAINED FOR FILE AND POSSIBLE | | | REVIEW BY THE FLORIDA BOARD OF ENGINEERS | | | AND STATE'S LEGAL COUNSEL. | | | | | | ** PLEASE KNOW, IT IS STRONGLY SUGGESTED | | | A MEETING BE HELD TO GO OVER COMMENTS | | | AND QUESTIONS BEFORE RE-SUBMITTING | | | PLANS. | | | THIS MAY HELP ALLEVIATE DELAYS IN | | | PROJECT AND THE HELP EXPEDITE THE | | | REVIEWS WHEN PLANS ARE BROUGHT BACK IN | | | FOR REVIEW. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | CONSTRUCTION SERVICES DEPT. | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-03-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-07 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-03-06 |
Time |
20:39 |
Sent To |
|
|
| Notes |
| 2006-03-07 00:00:00 | ********** UNSAT2ND REVIEW ********* | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW ,A ND NEW NOTES, DUE TO CHANGES | | | IN PLANS AND FBC. | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM FIRST REVIEW WITH NOTES | | | FOR 2ND REVIEW DIRECTLY ABOVE. | | | | | | | | | 1)NOTE: NOTE #1 OK, HOWEVER PLEASE SEE | | | FACP WAS REMOVED FROM STAIR, HOWEVER | | | THIS PANEL FOR THIS SPACE IS BEING SHOWN | | | OUTSIDE TENANT SPACE? IS THIS PANEL THE | | | BASE BLDG PANEL OR TENANT PANEL? | | | PLEASE SEE FIRE REVIEW COMMENTS FRO | | | LOCATION ETC. | | | | | | **PLEASE SEE THAT FIRE ALARM | | | CONTROL PANEL SHALL "NOT" BE LOCATED IN | | | THE STAIRWAY AS SHOWN. | | | EQUIPMENT ONLY PERTAINING THE FUNCTION | | | OF THE STAIRWAY MAY BE LOCATED IN THOSE | | | LOCATIONS. | | | PLEASE ALSO SEE NOTES FROM CHIEF FIRE | | | MARSHAL. | | | | | | 2)NOTE:NOTE #2 NO. PLEASE SEE | | | PHOTOMETRICS SUBMITTED ARE NOT SIGNED, | | | DATED OR SEAL BY THE DESIGN PROFESSIONAL | | | OR PERSON RESPONSIBLE FOR | | | DESIGN/PLANS.106.3.4.3 | | | PLEASE ALSO SEE MIN LIGHTING LEVELS DO | | | NOT SEEM TO HAVE BEEN ACHIEVED. | | | PLEASE SEE NFPA-101 7.8.1.3 | | | | | | **PLEASE SEE NFPA-101 2003, 7.8, | | | 7.9 WHICH REQUIRES A MIN OF 10 | | | FT/CANDLES AT STAIR EGRESS LOCATIONS. | | | PLEASE SEE MIN FT CANDLES UNDER EM | | | POWERE REQUIRED AT 1FT/CAN. | | | PLEASE PROVIDE BRIEF PHOTO-METRICS FOR | | | STAIR/EGRESS LOCATIONS. | | | | | | 3)NOTE:NOTE #3 NO, PLEASE SEE SOME | | | CIRCUITING STILL MISSINGON PLANS FOR | | | FIXTURES. PLEASE SEE EM LT, REDLINED | | | PLANS. | | | | | | **PLEASE SHOW ALL CIRCUTING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULES. | | | PLEASE SEE CIRCUTING FOR EM/EXT LTS | | | SHALL BE PER 700.12E WHICH REQUIRES THE | | | BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | 4)NOTE: NOTE #4 NO, PLEASE SEE CU'S ON | | | MECHANICAL PLANS AND OCP INDICATED ON | | | "M" SHEETS AND PANEL SCHEDULE. PLANS | | | REDLINED. ( 25A, 30A?) | | | | | | ** PLEASE CORRELAT PANEL SCHEDULE, | | | A/C EQUIPMENT AND LOADS. | | | PLEASE SEE AHU'S SHOWN AS 3-PHASE IN | | | LOADS AND ON SCHEDULE, HOWEVER ALSO | | | NOTED AS 2-POLE BRKRS?? | | | PLEASE SEE LOAD CALCULATIONS ONLY | | | INCLUDES LOADS FOR ONE UNIT. | | | PLEASE REVISE AS NEEDED. | | | PLEASE ALSO CALRIFY WHAT SEEMS TO | | | INDICATE 4-CU'S ON PANEL SCHEDULE, YET | | | ONLY TWO AHU'S ARE SHOWN? | | | | | | 5)NOTE:NOTE #5 OK, (NOTED AS FUTURE). | | | | | | | | | 6)NOTE: NOTE # 6 OK. | | | | | | NEW NOTES. | | | | | | 7)NOTE: PLEASE SEE 620.23 FOR MIN | | | REQUUIRED DEDICATED CIRCUIT(S) FOR | | | ELEVATOR EQUIPMENT ADDED TO PLANS. | | | | | | 8)NOTE: PLEASE SEE A BATTERY BACK UP EM | | | LT WILL BE REQUIRED IN ELEV EQUIPMENT | | | RM,7.8,700.16, ELEV SAFETY CODE. | | | | | | 9)NOTE: PLEASE SEE FBC 2004CHAPTER 13 | | | FOR COMMERCIAL BLDGS.13-415.1.ABC.1.1&2 | | | FOR MEANS OF CONTROL FOR LIGHTING, SPACE | | | CONTROL ETC. | | | | | | 10)NOTE: PLEASE COMPLETE FIXTURE | | | SCHEDULE SUBMITTED. PLEASE SEE FIXTURES | | | NOW SHOWN ON PLANS WHICH ARE NOT LABELED | | | OR ON FIX SCHEDULE? | | | | | | 11)NOTE: PLEASE SEE COPY OF FS | | | 553.80(2)(B) WITH RESPECT TO REPEAT | | | COMMENTS AND DESIGN PROFESSIONALS. | | | | | | ** PLEASE SEE ON PREVIOUS REVIEW IT WAS | | | REQUESTED TO REMOVE ALL OLD/VOIDED | | | SHEETS AND TO INSERT NEW REVISED SHEETS | | | INTO SETS AND TO SUBMIT ONE COPY OF THE | | | OLD VOIDED SHEETS. THE NEW SHEETS WERE | | | INSERTED, HOWEVER THE OLD /VOIDED SHEETS | | | WERE NOT SUBMITTED FOR REFERENCE. PLEASE | | | KNOW IT WILL HELP IN EXPEDITING THE | | | REVIEW PROCESS BY SUBMITTING THE OLD | | | SHEETS. | | | IT ALSO HELPS THE REVIEW PROCESS OF A | | | DETAILED RESPONSE LETTER FROM DESIGN | | | PROFESIONAL IS SUBMITTED FOR TRADES | | | ALSO. IT WAS NOTED, A DETAILED RESPONSE | | | WAS SUBMITTED FOR "A" SHEETS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-11-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-17 |
Time |
07:20 |
Rev Time |
0.75 |
| Received By |
dpalmer |
Date |
2005-11-17 |
Time |
06:58 |
Sent To |
|
|
| Notes |
| 2005-11-17 00:00:00 | ********** UNSAT ************** | | | | | | | | | 1)NOTE: PLEASE SEE THAT FIRE ALARM | | | CONTROL PANEL SHALL "NOT" BE LOCATED IN | | | THE STAIRWAY AS SHOWN. | | | EQUIPMENT ONLY PERTAINING THE FUNCTION | | | OF THE STAIRWAY MAY BE LOCATED IN THOSE | | | LOCATIONS. | | | PLEASE ALSO SEE NOTES FROM CHIEF FIRE | | | MARSHAL. | | | | | | 2)NOTE: PLEASE SEE NFPA-101 2003, 7.8, | | | 7.9 WHICH REQUIRES A MIN OF 10 | | | FT/CANDLES AT STAIR EGRESS LOCATIONS. | | | PLEASE SEE MIN FT CANDLES UNDER EM | | | POWERE REQUIRED AT 1FT/CAN. | | | PLEASE PROVIDE BRIEF PHOTO-METRICS FOR | | | STAIR/EGRESS LOCATIONS. | | | | | | 3)NOTE: PLEASE SHOW ALL CIRCUTING ON | | | PLANS AND CORRELATE WITH THE SUBMITTED | | | PANEL SCHEDULES. | | | PLEASE SEE CIRCUTING FOR EM/EXT LTS | | | SHALL BE PER 700.12E WHICH REQUIRES THE | | | BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | | | | 4)NOTE: PLEASE CORRELAT PANEL SCHEDULE, | | | A/C EQUIPMENT AND LOADS. | | | PLEASE SEE AHU'S SHOWN AS 3-PHASE IN | | | LOADS AND ON SCHEDULE, HOWEVER ALSO | | | NOTED AS 2-POLE BRKRS?? | | | PLEASE SEE LOAD CALCULATIONS ONLY | | | INCLUDES LOADS FOR ONE UNIT. | | | PLEASE REVISE AS NEEDED. | | | PLEASE ALSO CALRIFY WHAT SEEMS TO | | | INDICATE 4-CU'S ON PANEL SCHEDULE, YET | | | ONLY TWO AHU'S ARE SHOWN? | | | | | | 5)NOTE: PLEASE SEE WATER HEATER IS SHOWN | | | AS A 5KW UNIT ON A 1-POLE 25A BRKR? | | | PLEASE ADJUST.(MISPRINT). | | | | | | 6)NOTE: PLEASE VERIFY PLANS AND RISER AS | | | PLANS INDICATE (2) PANEL "B"'S BEING | | | LOCATED AT LOCATION, ONE BEING RELOCATED | | | AND ONE BEING ABANDONED? | | | RISER DOES NOT INCLUDE THE 2ND PANEL | | | "B". | | | PLEASE NOTE, IF CIRCUITS FROM THIS | | | ABANDONED PANEL ARE BEING RELOCATED?? | | | 215.5 | | | | | | ** PLEASE SEE ANY POSSIBLE NOTES FROM | | | OTHER REVIEWER(S) WHICH MAY AFFECT | | | ELECTRICAL PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | ONE SET OF OLD/VOIDED SHEETS SHOULD BE | | | SUBMITTED BACK WITH NEW SETS FOR | | | REFERENCE OF OLD/VOIDED SHEETS. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION | | | FOR REVIEW. IF THERE ARE ANY QUESIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2006-11-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2006-11-06 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2006-11-06 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2006-11-06 13:10:53 | *****PROVISO***** | | | | | | | | | | | | RESUBMITTED PLANS WILL BE STAMPED (PASSED) ONCE ALL | | | OTHER PLAN REVIEWS COMMENTS HAVE BEEN ADDRESSED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-06-21 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-06-21 |
Time |
10:07 |
Sent To |
|
|
| Notes |
| 2006-06-21 00:00:00 | ***DENIED*** | | | | | | 1) PLEASE SEE OTHER REVIEW COMMENTS | | | REGARDING FS AND FAC REQUIREMENTS FOR | | | PLANS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2006-03-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-03-29 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-03-29 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2006-03-29 00:00:00 | ******PROVISO****** | | | | | | 1) WORK SHALL COMPLY WITH NFPA 101, 2003 | | | EDITION CHAPTER 36. | | | | | | 2) IN ADDITION TO THE HEIGHT | | | REQUIREMENT, ADDRESS SHALL BE | | | CONTRASTING TO THE BACKGROUND. | | | | | | 3) FOR NEW INSTALLATIONS, DUCT SMOKE | | | DETECTORS SHALL CAUSE A GENERAL FIRE | | | ALARM IN ACCORDANCE WITH LOCAL | | | REQUIREMENTS. | | | | | | PLANS WILL BE STAMPED WHEN RESUBMITTED | | | FOR OTHER REVIEW COMMENTS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-11-10 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2005-11-10 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2005-11-10 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2005-11-10 00:00:00 | 1. DEMOLITION, RENOVATION, AND | | | CONSTRUCTION TO COMPLY WITH NFPA 241. | | | | | | 2. DEBRIS SHALL BE REMOVED FROM THE | | | SITE DAILY. | | | | | | 3. NO CUTTING OR WELDING ALLOWED WITHOUT | | | APPROVAL OF THE FIRE PREVENTION BUREAU | | | AND WITH COMPLIANCE WITH NFPA 51B. | | | | | | 4. PLANS DISPLAY RELOCATED FIRE ALARM | | | AND SECURITY PANEL TO BE PLACED INSIDE | | | STAIRWELL. THIS ACTIVITY WILL NOT BE | | | ALLOWED. | | | | | | 5. PLEASE PROVIDE PRESCRIPTIVE STRENGTH | | | REQUIREMENTS FOR ALL GUARDRAILS. LOCATED | | | INFORMATION ON PAGE A-5. | | | | | | 6. A CHANGE OF USE IS OCCURING. ALL NEW | | | MERCANTILE REQUIREMENTS SHALL BE MET. | | | | | | 7. BUILDING ADDRESS REQUIRED ON | | | ELEVATION. A MINIMUM OF AT LEAST 6" | | | HIGH NUMBERS ARE REQUIRED. | | | | | | 8. SEPERATE PLANS AND PERMITS REQUIRED | | | FOR FIRE ALARM SYSTEM EQUIPMENT. | | | | | | 9.SEPERATE PLANS AND PERMITS REQUIRED | | | FOR FIRE SPRINKLER SYSTEM REMODEL. | | | | | | 10. PLEASE PROVIDE A LIFE SAFETY PLAN | | | AND ILLUSTRATE EXITING RATIONALE FOR | | | PROPOSED SPACE. | | | | | | MIKE CARSILLO, CHIEF FIRE PREVENTION | | | OFFICER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-11-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-17 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-17 |
Time |
11:01 |
Sent To |
E |
|
| Notes |
| 2006-11-17 11:01:57 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-10-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-10-04 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-10-04 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2006-10-19 16:19:23 | TO "COMM" BD#39 | | 2006-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-12 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-12 |
Time |
14:18 |
Sent To |
|
|
| Notes |
| 2006-06-02 00:00:00 | TO "COMM" BD#34 | | 2006-05-12 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-02-06 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-02-06 |
Time |
09:22 |
Sent To |
|
|
| Notes |
| 2006-03-06 00:00:00 | TO "COMM" BD#49 | | 2006-02-06 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-20 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-04 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2005-10-13 00:00:00 | TO "COMM" BD#3 | | 2005-10-04 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-10-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-10-31 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-10-31 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2006-10-31 10:57:53 | COMMENT BY HAROLD MOSER FROM 6/22/06 WAS ADDRESSED |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-06-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-06-22 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-06-22 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2006-06-22 00:00:00 | PLAN DENIED | | | PLEASE REFER TO SECTION 307.2.3#1 | | | AUXILIARY AND SECONDARY DRAIN SYSTEM. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-03-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-03-27 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-03-27 |
Time |
09:41 |
Sent To |
|
|
| Notes |
| 2006-03-27 00:00:00 | PLAN DENIED | | | 1) PLEASE PROVIDE MANUFACYURERS | | | INSTALLATION INSTRUCTIONS ON POWER UNIT | | | AND TANK CONTROLLER. | | | 2) PLEASE REFER TO SECTION 607.1.2 | | | 2001FBC(M) LOCATION OF FIRE DAMPERS. | | | PAGE M-1 SHOWS RETURN AIR DUCT | | | PENETRATING FIRE RATED WALL. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-10-06 |
Time |
11:57 |
Rev Time |
1.50 |
| Received By |
prafter |
Date |
2005-10-06 |
Time |
11:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-12-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-12-08 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2005-12-08 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-10-25 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2006-10-25 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2006-10-25 |
Time |
14:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2006-03-31 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2006-03-31 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-12-15 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2005-12-15 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2005-12-15 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2005-12-15 00:00:00 | VERIFY ALLOWABLE PERCENTAGE OPENINGS | | | ALONG NORTH ELEVATION (ALLEY SIDE) PER | | | FIRE/BUILDING CODE REQ'S. -MJF |
|
|