Plan Review Details - Permit 05100006
Plan Review Stops For Permit 05100006
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
2006-11-20 18:17:35"A" SHEETS NEEDS STAMPING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-10-26 Cont ID  
Sent By shill Date 2006-10-26 Time 14:10 Rev Time 0.00
Received By shill Date 2006-10-26 Time 11:30 Sent To  
Notes
2006-10-26 14:12:12***PROVISOS***
  
 1.)A1, LANDING AT THE TOP OF THE RAMP IS TO BE
 60"MIN, FBC11-4.8.4.PLAN REDLINED.
  
 2.)SEPARATE PERMIT REQUIRED FOR THE AWNING.
  
 3.)SUBMIT THE ENERGY CALC WITH THE OWNER/AGENT LINE
 SIGNED, FBC13-103.1.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-06-13 Cont ID  
Sent By shill Date 2006-06-13 Time 13:44 Rev Time 0.00
Received By shill Date 2006-06-13 Time 08:51 Sent To  
Notes
2006-06-13 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 SECOND REVIEW
  
 COMMENTS FROM FIRST REVIEW:
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 PLEASE KEEP THE NOC PROVIDED IN THE
 PERMIT APPLICATION PACKAGE.
  
 2-7.)ADDRESSED.
  
 8.)PROVIDE CERTIFICATION IN REGARDS TO
 THE FLOOR LOADING, SECOND FLOOR.SHOW
 COMPLIANCE WITH FBC TABLE 1607.1.
  
 3RD REVIEW - THE NEW NOTE REFERS TO "IN
 ACCORANCE WITH SBC TABLE".WRONG CODE;
 NO TABLE REFERENCED.
  
 9. - 10)ADDRESSED.
  
 11.)VERTICAL ACCESSIBILITY REQUIRED,
 FBC EB 806, FBC11-4.1.6(1)(B).
  
 ADDRESSED, BUT PLEASE SHOW SIGNAGE
 REQUIRED BY FBC11-4.10.5.
  
 3RD REVIEW - PROVIDE SIGNAGE
 INFORMATION.A CODE REFERENCE WAS
 PROVIDED, BUT NO DETAIL OR SPECIFICATION
 PROVIDED.
  
 12-27.)PRODUCT APPROVALS ARE TO BE
 REVIEWED BY DESIGNER OF RECORD,
 FBC*106.3.3.
  
 NO PRODUCT APPROVALS SUBMITTED.PLEASE
 HAVE REVIEWED BY DOR AND SUBMIT.
  
 CODE COMPLIANCE CANNOT BE DETERMINED
 UNTIL DESIGN PRESSURE ISSUES RESOLVED.
 PRODUCT APPROVALS ARE TO BE REVIEWED BY
 DESIGNER OF RECORD, NOT ADDRESSED.
  
 NEW COMMENTS:
  
 28-31.) ADDRESSED.
  
 32.)SEE ATTACHED FS553(80)(2)(B).A
 4X PLAN REVIEW FEE IS REQUIRED TO BE
 CHARGED IF COMMENTS NOT PROPERLY
 ADDRESSED A THIRD TIME.
  
 3RD REVIEW - 4X FEE CHARGED.NOTE THAT
 THIS FEE WILL BE CHARGED EVERY TIME IF
 COMMENTS NOT ADDRESSED.
  
 33.)THE HANDWRITTEN NUMBER FOR THE
 REVIEION TO THE AREA CALCS IS NOT THE
 SAME ON ALL SHEETS.ARE THERE OTHER
 DISCRPEANCIES?
  
 34.)CHANGES HANDWRITTEN TO THE PLAN
 ARE TO BE INITIALLED.
  
 35.)REMOVE OLD DATA FROM THE PLAN.
 THE OLD "DESIGN DATA" IS STILL ON THE
 PLAN WITH A CLOUD THAT STATES "DELETE".
 DELETE FROM THE PLAN.A NEW ONE HAS
 BEEN PASTED.INCORPORATE PROPERLY INTO
 THE SHEET.THIS IS NOT AN ACCEPTABLE
 WAY TO CHANGE A SEALED DRAWING AS THERE
 IS NO WAY TO TELL WHO MADE THIS CHANGE,
 AFTER THE SHEET WAS SIGNED AND SEALED.
  
 36.)BUILDING TYPE SHOULD INDICATE TYPE
 A OR B, FBC6.
  
 37.)HOW HAVE YOU DETERMINED DESIGN
 PRESSURES?SOME ARE THE SAME AS TABLE
 1609.6 FBC, BUT THIS BUILDING IS OVER
 30'.LARGER OPENINGS ON THE FIRST FLOOR
 HAVE DPS HIGHER THAN SMALLER OPENINGS.
  
 38.)INCORRECT CODE ON ENERGY CALCS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-03-22 Cont ID  
Sent By shill Date 2006-03-22 Time 11:38 Rev Time 4.00
Received By shill Date 2006-03-20 Time 09:37 Sent To  
Notes
2006-03-22 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 SECOND REVIEW
  
 COMMENTS FROM FIRST REVIEW:
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 PLEASE KEEP THE NOC PROVIDED IN THE
 PERMIT APPLICATION PACKAGE.
  
 2.)PLEASE ADJUST THE VALUE ON THE
 PERMIT APPLICATION.I UNDERSTAND THAT
 THIS AMOUNT IS FOR THE DEMOLITION ONLY,
 WHICH WILL BE ON A SEPARATE PERMIT.
  
 NOT ADDRESSED.
  
 3. - 7.)ADDRESSED.
  
 8.)PROVIDE CERTIFICATION IN REGARDS TO
 THE FLOOR LOADING, SECOND FLOOR.SHOW
 COMPLIANCE WITH FBC TABLE 1607.1.
  
 THE NOTE DOES NOT INDICATE THAT THIS IS
 A FLOOR CERTIFICATION.IT APPEARS TO BE
 THE DESIGN CRITERIA.AS IT IS EXISTING,
 DESIGN CRITERIA DOES NOT SHOW
 COMPLIANCE.
  
 9. ? 10)ADDRESSED.
  
 11.)VERTICAL ACCESSIBILITY REQUIRED,
 FBC EB 806, FBC11-4.1.6(1)(B).
  
 ADDRESSED, BUT PLEASE SHOW SIGNAGE
 REQUIRED BY FBC11-4.10.5.
  
 12.)THE WEST END OF THE MEZZANINE HAS
 A 6IN STEP.SEE FBC11-4.1(1)(A).AN
 ACCESSIBLE ROUTE SHALL CONNECT
 ACCESSIBLE ELEMENTS AND SPACES,
 FBC11-4.1.2(2).
  
 A CONCRETE RAMP IS NOW SHOWN.INDICATE
 ON THE PLAN WHAT THE ADDITIONAL LOAD IS
 AND CONFIRM THAT THE EXISTING CONDITIONS
 CAN ACCOMDATE THE ADDITIONAL DEAD LOAD.
  
 SHOW RAMP WIDTH, BOTH RAMPS,
 FBC11-4.8.3.
  
 13-16.)ADDRESSED.
  
 17.)PROVIDE A FIRE SPRINKLER
 SCHEMATIC, FBC*106.3.5.1.1(5).
  
 THIS WAS PROVIDED.CLARIFY AS TO WHY
 THERE ARE NOT SPRINKLER HEADS, FIRST
 FLOOR, IN THE ENTRY AREA AND CENTER.
 ALSO CLARIFY AS TO HOW THE SPRINKLER
 HEADS SECOND FLOOR, 28FT ABOVE FINISH
 FLOOR, IN THE OPEN AREA WILL BE
 EFFFECTIVE.
  
 18-19.)ADDRESSED.
  
 20.)ADDRESSED.
  
 21.)PROVIDE DETAILS FOR THE EXISTING
 STAIRS AND HANDRAILS.SHOW COMPLIANCE
 WITH FBC1009, FBC11-4.9.
  
 RESPONSE LETTER STATES THAT THERE ARE
 TWO EXITS.ONLY ONE SHOWN ON THE LIFE
 SAFETY PLAN FOR BOTH THE FIRST FLOOR AND
 THE SECOND FLOOR.EXIT LIGHTS SHOULD BE
 SHOWN AT ALL EXITS.THE TWO EXITS ARE
 TO BE REMOTELY LOCATED FBC104.2.1(2).
 THE DISTANCE BETWEEN THE TWO STAIRS,
 SECOND FLOOR DO NOT APPEAR TO BE ONE
 THIRD DISTANCE APART.INDICATE ON THE
 PLAN THAT BOTH EXITS ARE ACCESSIBLE
 (SHOW ELEVATION CHANGE AT DOORWAYS).
  
 REVISE THE LIFE SAFETY PLAN AND ELECTRIC
 PLAN TO CLEARLY SHOW TWO EXITS WHICH DO
 NOT EXCEED TRAVEL DISTANCE OR COMMON
 PATH OF TRAVEL.
  
 DETAIL 3A7, THE STAIR RAIL ALSO SERVES
 AS A GUARDRAIL.THE HEIGHT IS TO COMPLY
 WITH FBC1012.2.
  
 22.)SHOW REQUIRED TENANT SEPARATION ON
 THE EXISTING WALLS, FBC708.
  
 NO SEPARATION SHOWN BETWEEN BLDG ELEC
 AND THE RENOVATED SPACE.
  
 SHOW CONTINUITY REQUIRED BY FBC708.4.
  
 23-26.)ADDRESSED.
  
 27.)PRODUCT APPROVALS ARE TO BE
 REVIEWED BY DESIGNER OF RECORD,
 FBC*106.3.3.
  
 NO PRODUCT APPROVALS SUBMITTED.PLEASE
 HAVE REVIEWED BY DOR AND SUBMIT.
  
 NEW COMMENTS:
  
 28.)ELEVATOR IS TO CONFORM TO
 ASME17.1, FBC30.NOTE THE REQUIREMENT
 ON THE PLAN.
  
 29.)PROVIDE ELEVATOR SIGNAGE
 FBC3002.3.
  
 30.)DECLARE OCCUPANCY OF ADJACENT
 SPACES, INCLUDING THE THIRD FLOOR.SEE
 FBC TABLE 302.3.2.SHOW OCCUPANCY
 SEPARATION OR TENANT SEPARATION AND
 CONTINUITY FBC706.4.
  
 31.)FBC1019.1.5, STORAGE IS SHOWN
 UNDER STAIR 2.SHOW REQUIRED FIRE
 PROTECTION AND SPRINKLER.
  
 32.)SEE ATTACHED FS553(80)(2)(B).A
 4X PLAN REVIEW FEE IS REQUIRED TO BE
 CHARGED IF COMMENTS NOT PROPERLY
 ADDRESSED A THIRD TIME.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2005-12-20 Cont ID  
Sent By shill Date 2005-12-20 Time 11:10 Rev Time 6.00
Received By shill Date 2005-12-12 Time 16:07 Sent To  
Notes
2005-12-20 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.
  
 2.)PLEASE ADJUST THE VALUE ON THE
 PERMIT APPLICATION.I UNDERSTAND THAT
 THIS AMOUNT IS FOR THE DEMOLITION ONLY,
 WHICH WILL BE ON A SEPARATE PERMIT.
  
 3.)THE ENERGY CALCS STATE THAT THE
 AREA IS 6708, SHEET COV IS 6762.
  
 4.)ALTHOUGH THE PLANS REFER TO THE
 SECOND STORY AS A MEZZANINE, IT IS NOT A
 MEZZANINE BY DEFINITION, FBC502.1.
  
 5.)COV, GENERAL NOTE #2 REFERS TO
 FBC2001.GOVERNING CODE IS FBC2004
 EFFECTIVE OCTOBER 1, 2005.
  
 6.)PROVIDE TOTAL AREA OF THE BUILDING,
 FBC EB CODE CHAPTER 3.
  
 7.)A CHANGE OF OCCUPANCY IS TO COMPLY
 WITH FBC EB CHAPTERS 5 THROUGH 7, FBC EB
 812.1.2.
  
 8.)PROVIDE CERTIFICATION IN REGARDS TO
 THE FLOOR LOADING, SECOND FLOOR.SHOW
 COMPLIANCE WITH FBC TABLE 1607.1.
  
 9.)SEE ATTACHED POLICY, ITEMS 13 AND
 14, IN REGARDS TO IMPACT PROTECTION.
 USE OF REMOVABLE SHUTTERS ON THE SECOND
 FLOOR OF COMMERCIAL BUILDINGS IS
 PROHIBITED.USE OF REMOVABLE SHUTTERS
 ON THE FIRST FLOOR REQUIRES APPROVAL BY
 THE BUILDING OFFICIAL.
  
 10.)THERE IS NO ACCESS TO THE TOILET
 VESTIBULE.ADDRESS.
  
 11.)VERTICAL ACCESSIBILITY REQUIRED,
 FBC EB 806, FBC11-4.1.6(1)(B).
  
 12.)THE WEST END OF THE MEZZANINE HAS
 A 6IN STEP.SEE FBC11-4.1(1)(A).AN
 ACCESSIBLE ROUTE SHALL CONNECT
 ACCESSIBLE ELEMENTS AND SPACES,
 FBC11-4.1.2(2).
  
 13.)WHAT WAS LOCATED IN THE AREA
 MARKED ?VOID? ON THE PLAN?
  
 14.)SHOW THE PROPERTY LINE ON THE
 PLAN, OR PROVIDE A SITE PLAN.THE
 EXTERIOR STAIR DOOR SHALL NOT OPEN INTO
 THE PUBLIC RIGHT-OF-WAY.SEE FBC EB
 812.1.2, FBC EB 605, FBC3202.2.
  
 15.)THE AWNING IS TO COMPLY WITH
 FBC3202.3.1.SHOW COMPLIANCE ON THE
 PLAN.
  
 16.)DOES THE ELEVATOR OPEN INTO A
 COMMON AREA?
  
 17.)PROVIDE A FIRE SPRINKLER
 SCHEMATIC, FBC*106.3.5.1.1(5).
  
 18.)SPECIFY INTERIOR FINISH
 CLASSIFICATION FBC803.
  
 19.)SPECIFY WALL FINISH IN THE
 BATHROOMS, FBC1210.2.
  
 20.)PROVIDE A ROOM DESIGNATION,
 MEZZANINE WEST, AT DOOR 21.IF THIS IS
 STORAGE PROVIDE INFORMATION AS TO WHAT
 WILL BE STORED THERE AND AREA
 CALCULATION, SEE FBC302.3.2, FBC309.
  
 21.)PROVIDE DETAILS FOR THE EXISTING
 STAIRS AND HANDRAILS.SHOW COMPLIANCE
 WITH FBC1009, FBC11-4.9.
  
 22.)SHOW REQUIRED TENANT SEPARATION ON
 THE EXISTING WALLS, FBC708.
  
 23.)SHOW MANEUVERING CLEARANCE, PULL
 SIDE, FOR DOORS 21, 15, FBC11-4.13.6,
 FIGURE 11-25.
  
 24.)THE ACCESSIBLE WATER CLOSET SHALL
 BE LOCATED IN THE CORNER, DIAGONAL TO
 THE DOOR, FBC11-4.17.3 EXCEPTION (2).
  
 25.)PROVIDE A DETAIL FOR PENETRATIONS
 THROUGH THE TENANT SPACES ABOVE.
  
 26.)PROVIDE A MINIMUM CLEARANCE FOR
 THE CONDENSING UNIT, M2, FBC TABLE
 1509.7.
  
 27.)PRODUCT APPROVALS ARE TO BE
 REVIEWED BY DESIGNER OF RECORD,
 FBC*106.3.3.

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-20 Cont ID  
Sent By dpalmer Date 2006-11-20 Time 18:16 Rev Time 0.00
Received By dpalmer Date 2006-11-20 Time 17:56 Sent To B
Notes
2006-11-20 18:17:08ELECTRICAL PLANS STAMPED.
 SENT TO BLUIDING AS "A" SHEETS NEED STAMPING.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-10-27 Cont ID  
Sent By dpalmer Date 2006-10-27 Time 07:46 Rev Time 0.00
Received By dpalmer Date 2006-10-27 Time 06:58 Sent To  
Notes
2006-10-27 07:46:58***UNSAT 4TH REVIEW ***
  
 1) NOTE: PLEASE SEE NOTES FROM PREVIOUS REVIEW. PLEASE
 SEE FBC CHAPTER 13, 13-415.1.1, .1.2 AND .1.3.
 PLEASE SEE AS PREVIOUSLY NOTED, MULTIPLE FOORS AND
 AREAS AND REQUIREMENTS FOR OVER RIDES DEVICES. PLEASE
 KNOW THIS WAS GONE OVER IN MEETING AND ONE ITEM
 MENTIONED WAS GOING TO BE THATOCC SENSORS WERE GOING
 TO BE ADDEDTO SECOND FLR FOR OVER RIDE CONTROL???
 PLEASE KNOW, IF AN OCCUPANT IS ON THE 2ND FLR AND TIME
 EXPIRES ON SYSTEM SCHEDULEING, THE OCCUPANT MUST BE
 ABLE TO OVER RIDE SYSTEM. THIS CAN BE DONE IN MULTIPLE
 WAYS, HOWEVER THE ONLY DEVICE SHOWN IS THE ONE LOCATED
 AT THE FRONT DOOR??
 PLEASE SEE ALL OTHER AREAS /ROOMS CONTAING FLOOR TO
 CEILING HEIGHT PARTITIONS SHALL ALSO CONTAIN OVER RIDE
 DEVICES, WHETHER OCC SENSOR TYPE OR TIME TYPE.
 PLEASE SEE IF USING OS TYPE , PLEASE LIST ON SYMBOL
 LEGEND THE MAX TIMES PERMITTED.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-06-09 Cont ID  
Sent By dpalmer Date 2006-06-09 Time 20:24 Rev Time 0.00
Received By dpalmer Date 2006-06-09 Time 19:38 Sent To  
Notes
2006-06-09 00:00:00*********** UNSAT 3RD REVIEW *********
  
 ** PLEASE SEE SOME COMMENTS FROM
 PREVIOUS REVIEWS AND SOME NEW COMMENTS
 DUE TO THE PLANS BEING SUBMITTED.
  
 1) NOTE: PLEASE SEE AS REQUESTED ON THE
 TWO PREVIOUS REVIEWS, PHOTO-METRICS ARE
 TO BE PROVIDED WHICH MEET THE MINIMUM
 REQUIREMENTS AS SET FORTH IN THE 2003
 NFPA-101 LIFE SAFETY CODE.
 PLEASE SEE THE RESPONSE MENTIONED THAT
 THIS HAD BEEN ACHIEVED ON BOTH SETS
 SUBMITED, HOWEVER AS STATED ON PREVIOUS
 REVIEWS: 7.8.1.3 UNDER NORMAL
 CONDITIONS, THE LIGHTING LEVELS ARE TO
 BE 10FT CANDLES MIN(AVG)(108 LUX)AND
 ONLY UNDER EMERGENCY CONDITIONS CAN THE
 LIGHTING LEVELS BE REDUCED TO 1FT CANDLE
 AVG MIN (10.8LUX). PLEASE SEE STAIR
 LOCATIONS DO NOT SHOW THIS.
 PLEASE SEE THIS IS NOT SHOWN ON PLANS.
 PLEASE SEE ON PREVIOUS REVIEW IT WAS
 REQUESTED THE PERSON RESPONSIBLE FOR
 LIGHTING DESIGN/PHOTO-METRICS WHICH IS
 THE ENGINEER OF RECORD SHALL SIGN,DATE
 AND SEAL PLANS.
 PLEASE SEE LIGHTING DESIGN IS NOW SHOWN
 BY ANOTHER PERSON WHICH IS NOT SIGNED
 PER FBC 104.2.1,106.3 ADMINISTRATIVE
 SEC.
  
 2) NOTE: PLEASE SEE PREVIOUS NOTE FOR
 THE 2004 FBC CHAPTER 13.
 13-415.1.ABC.1.1, .1.2, .1.3 ETC.
 PLEASE SEE A TIME CLOCK IS MENTIONED IN
 RESPONSE HOWEVER THIS IS NOT THE ONLY
 ITEM REQUIRED.
 PLEASE SEE MULTIPLE FLOORS, OVER RIDES,
 LOCATIONS, SCHEDULING ETC COULD NOT BE
 LOCATED.
 PLEASE SEE MORE THAN ONE SYSTEM IS
 REQUIRED WHEN MORE THAN ONE FLOOR IS IN
 SCOPE ETC.
 PLEASE SEE ENERGY CALCS SUBMITTED
 INDICATE THE 2001 FBC?, YET PLANS ARE TO
 BE UNDER THE 2004 FBC. PLEASE SEE
 13-415.1.AB.1 AND PRESCRIPTIVE METHODS
 WHICH MUST BE DONE FOR RENOVATIONS. "C".
  
 3) NOTE: PLEASE SEE VALUATION FOR SCOPE
 OF WORK HAS STILL NOT BEEN ADJUSTED.
 PLEASE SEE FBC ADMINISTRATIVE SECTION AS
 ADOPTED BY THE CITY OF WEST PALM BEACH
 108.3. COMPLETE SCOPE PF WORK SHALL
 INCLUDE ALL LABOR AND MATERIALS.
 PLEASE SEE THE FOLLOWING COMMENT AS THE
 FEES WILL BE AFFECTED.
  
 4) NOTE: PLEASE SEE A NOTICE WAS GIVEN
 ON PREVIOUS REVIEW WITH REFERENCE TO THE
 FS 553.80(2)(B) WITH RESPECT TO REPEAT
 COMMENTS THREE OR MORE TIMES.
 PLEASE SEE A 4X FEE FOR THE PLAN REVIEW
 PORTION OF THE EMIT FEE HAS NOW BEEN
 ASSESSED AND SHALL BE PAID BEFORE
 RE-SUBMITTING PLANS FOR THE NEXT REVIEW.
 PLEASE KNOW THE VALUE FOR SCOPE OF WORK
 WILL BE ASSESSED BY THIS DEPARTMENT
 WHICH WILL AFFECT THIS FINE.
  
 **
 NEW NOTES;
  
 5) NOTE: PLEASE SEE PLANS NOW PLANS ARE
 BEING SUBMITTED DONE BY AN ENGINEER AND ENGINEERING
 FIRM.
 PLEASE SEE FLORIDA ADMINISTRATIVE CODE 61G15-23.002
 WHICH REQUIRES THE PRINTED
 NAME AND LICENSE NUMBER OF SAID ENGINEER
 ON TITLE BLOCKS. THIS SAME SECTION ALSO
 REQUIRES A CERTIFICATE OF AUTHORIZATION
 NUMBER FOR SAID ENGINEERING FIRM AS
 REQUIRED PER FS 471.023
  
 6) NOTE: PLEASE SEE ELECTRICAL PLANS
 ALSO CONTAIN A "STAMP" FOR THE SIGNATURE
 OF THE SAID ENGINEER WHICH UNDER FS
 471.025, FAC 61G15-23.002 IS REQUIRED TO
 BE ORIGINAL SIGNATURE AND DATED.
 PLEASE SEE ONLY THE DATE IS IN ORIGINAL
 "WET" INK.
 PLEASE KNOW, STAMPS FOR SIGNATURES ARE
 NOT PERMITTED UNDER FS/ FAC.
 PLEASE ALSO KNOW, BOTH SETS OF
 ELECTRICAL PLANS AND ORIGINAL ELECTRICAL
 PLANS DONE BY THE ARCHITECT ARE ALL
 BEING RETAINED FOR FILE AND POSSIBLE
 REVIEW BY THE FLORIDA BOARD OF ENGINEERS
 AND STATE'S LEGAL COUNSEL.
  
 ** PLEASE KNOW, IT IS STRONGLY SUGGESTED
 A MEETING BE HELD TO GO OVER COMMENTS
 AND QUESTIONS BEFORE RE-SUBMITTING
 PLANS.
 THIS MAY HELP ALLEVIATE DELAYS IN
 PROJECT AND THE HELP EXPEDITE THE
 REVIEWS WHEN PLANS ARE BROUGHT BACK IN
 FOR REVIEW.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTRUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-03-07 Cont ID  
Sent By dpalmer Date 2006-03-07 Time 11:39 Rev Time 0.00
Received By dpalmer Date 2006-03-06 Time 20:39 Sent To  
Notes
2006-03-07 00:00:00********** UNSAT2ND REVIEW *********
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS
 REVIEW ,A ND NEW NOTES, DUE TO CHANGES
 IN PLANS AND FBC.
 PLEASE SEE NOTES BELOW ARE TAKEN
 DIRECTLY FROM FIRST REVIEW WITH NOTES
 FOR 2ND REVIEW DIRECTLY ABOVE.
  
  
 1)NOTE: NOTE #1 OK, HOWEVER PLEASE SEE
 FACP WAS REMOVED FROM STAIR, HOWEVER
 THIS PANEL FOR THIS SPACE IS BEING SHOWN
 OUTSIDE TENANT SPACE? IS THIS PANEL THE
 BASE BLDG PANEL OR TENANT PANEL?
 PLEASE SEE FIRE REVIEW COMMENTS FRO
 LOCATION ETC.
  
 **PLEASE SEE THAT FIRE ALARM
 CONTROL PANEL SHALL "NOT" BE LOCATED IN
 THE STAIRWAY AS SHOWN.
 EQUIPMENT ONLY PERTAINING THE FUNCTION
 OF THE STAIRWAY MAY BE LOCATED IN THOSE
 LOCATIONS.
 PLEASE ALSO SEE NOTES FROM CHIEF FIRE
 MARSHAL.
  
 2)NOTE:NOTE #2 NO. PLEASE SEE
 PHOTOMETRICS SUBMITTED ARE NOT SIGNED,
 DATED OR SEAL BY THE DESIGN PROFESSIONAL
 OR PERSON RESPONSIBLE FOR
 DESIGN/PLANS.106.3.4.3
 PLEASE ALSO SEE MIN LIGHTING LEVELS DO
 NOT SEEM TO HAVE BEEN ACHIEVED.
 PLEASE SEE NFPA-101 7.8.1.3
  
 **PLEASE SEE NFPA-101 2003, 7.8,
 7.9 WHICH REQUIRES A MIN OF 10
 FT/CANDLES AT STAIR EGRESS LOCATIONS.
 PLEASE SEE MIN FT CANDLES UNDER EM
 POWERE REQUIRED AT 1FT/CAN.
 PLEASE PROVIDE BRIEF PHOTO-METRICS FOR
 STAIR/EGRESS LOCATIONS.
  
 3)NOTE:NOTE #3 NO, PLEASE SEE SOME
 CIRCUITING STILL MISSINGON PLANS FOR
 FIXTURES. PLEASE SEE EM LT, REDLINED
 PLANS.
  
 **PLEASE SHOW ALL CIRCUTING ON
 PLANS AND CORRELATE WITH THE SUBMITTED
 PANEL SCHEDULES.
 PLEASE SEE CIRCUTING FOR EM/EXT LTS
 SHALL BE PER 700.12E WHICH REQUIRES THE
 BRANCH CIRCUIT FEEDING THE UNIT
 EQUIPMENT SHALL BE THE SAME BRANCH
 CIRCUIT AS THAT SERVING THE NORMAL
 LIGHTING IN THE AREA AND CONNECTED AHEAD
 OF ANY LOCAL SWITCHES.
  
 4)NOTE: NOTE #4 NO, PLEASE SEE CU'S ON
 MECHANICAL PLANS AND OCP INDICATED ON
 "M" SHEETS AND PANEL SCHEDULE. PLANS
 REDLINED. ( 25A, 30A?)
  
 ** PLEASE CORRELAT PANEL SCHEDULE,
 A/C EQUIPMENT AND LOADS.
 PLEASE SEE AHU'S SHOWN AS 3-PHASE IN
 LOADS AND ON SCHEDULE, HOWEVER ALSO
 NOTED AS 2-POLE BRKRS??
 PLEASE SEE LOAD CALCULATIONS ONLY
 INCLUDES LOADS FOR ONE UNIT.
 PLEASE REVISE AS NEEDED.
 PLEASE ALSO CALRIFY WHAT SEEMS TO
 INDICATE 4-CU'S ON PANEL SCHEDULE, YET
 ONLY TWO AHU'S ARE SHOWN?
  
 5)NOTE:NOTE #5 OK, (NOTED AS FUTURE).
  
  
 6)NOTE: NOTE # 6 OK.
  
 NEW NOTES.
  
 7)NOTE: PLEASE SEE 620.23 FOR MIN
 REQUUIRED DEDICATED CIRCUIT(S) FOR
 ELEVATOR EQUIPMENT ADDED TO PLANS.
  
 8)NOTE: PLEASE SEE A BATTERY BACK UP EM
 LT WILL BE REQUIRED IN ELEV EQUIPMENT
 RM,7.8,700.16, ELEV SAFETY CODE.
  
 9)NOTE: PLEASE SEE FBC 2004CHAPTER 13
 FOR COMMERCIAL BLDGS.13-415.1.ABC.1.1&2
 FOR MEANS OF CONTROL FOR LIGHTING, SPACE
 CONTROL ETC.
  
 10)NOTE: PLEASE COMPLETE FIXTURE
 SCHEDULE SUBMITTED. PLEASE SEE FIXTURES
 NOW SHOWN ON PLANS WHICH ARE NOT LABELED
 OR ON FIX SCHEDULE?
  
 11)NOTE: PLEASE SEE COPY OF FS
 553.80(2)(B) WITH RESPECT TO REPEAT
 COMMENTS AND DESIGN PROFESSIONALS.
  
 ** PLEASE SEE ON PREVIOUS REVIEW IT WAS
 REQUESTED TO REMOVE ALL OLD/VOIDED
 SHEETS AND TO INSERT NEW REVISED SHEETS
 INTO SETS AND TO SUBMIT ONE COPY OF THE
 OLD VOIDED SHEETS. THE NEW SHEETS WERE
 INSERTED, HOWEVER THE OLD /VOIDED SHEETS
 WERE NOT SUBMITTED FOR REFERENCE. PLEASE
 KNOW IT WILL HELP IN EXPEDITING THE
 REVIEW PROCESS BY SUBMITTING THE OLD
 SHEETS.
 IT ALSO HELPS THE REVIEW PROCESS OF A
 DETAILED RESPONSE LETTER FROM DESIGN
 PROFESIONAL IS SUBMITTED FOR TRADES
 ALSO. IT WAS NOTED, A DETAILED RESPONSE
 WAS SUBMITTED FOR "A" SHEETS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2005-11-17 Cont ID  
Sent By dpalmer Date 2005-11-17 Time 07:20 Rev Time 0.75
Received By dpalmer Date 2005-11-17 Time 06:58 Sent To  
Notes
2005-11-17 00:00:00********** UNSAT **************
  
  
 1)NOTE: PLEASE SEE THAT FIRE ALARM
 CONTROL PANEL SHALL "NOT" BE LOCATED IN
 THE STAIRWAY AS SHOWN.
 EQUIPMENT ONLY PERTAINING THE FUNCTION
 OF THE STAIRWAY MAY BE LOCATED IN THOSE
 LOCATIONS.
 PLEASE ALSO SEE NOTES FROM CHIEF FIRE
 MARSHAL.
  
 2)NOTE: PLEASE SEE NFPA-101 2003, 7.8,
 7.9 WHICH REQUIRES A MIN OF 10
 FT/CANDLES AT STAIR EGRESS LOCATIONS.
 PLEASE SEE MIN FT CANDLES UNDER EM
 POWERE REQUIRED AT 1FT/CAN.
 PLEASE PROVIDE BRIEF PHOTO-METRICS FOR
 STAIR/EGRESS LOCATIONS.
  
 3)NOTE: PLEASE SHOW ALL CIRCUTING ON
 PLANS AND CORRELATE WITH THE SUBMITTED
 PANEL SCHEDULES.
 PLEASE SEE CIRCUTING FOR EM/EXT LTS
 SHALL BE PER 700.12E WHICH REQUIRES THE
 BRANCH CIRCUIT FEEDING THE UNIT
 EQUIPMENT SHALL BE THE SAME BRANCH
 CIRCUIT AS THAT SERVING THE NORMAL
 LIGHTING IN THE AREA AND CONNECTED AHEAD
 OF ANY LOCAL SWITCHES.
  
 4)NOTE: PLEASE CORRELAT PANEL SCHEDULE,
 A/C EQUIPMENT AND LOADS.
 PLEASE SEE AHU'S SHOWN AS 3-PHASE IN
 LOADS AND ON SCHEDULE, HOWEVER ALSO
 NOTED AS 2-POLE BRKRS??
 PLEASE SEE LOAD CALCULATIONS ONLY
 INCLUDES LOADS FOR ONE UNIT.
 PLEASE REVISE AS NEEDED.
 PLEASE ALSO CALRIFY WHAT SEEMS TO
 INDICATE 4-CU'S ON PANEL SCHEDULE, YET
 ONLY TWO AHU'S ARE SHOWN?
  
 5)NOTE: PLEASE SEE WATER HEATER IS SHOWN
 AS A 5KW UNIT ON A 1-POLE 25A BRKR?
 PLEASE ADJUST.(MISPRINT).
  
 6)NOTE: PLEASE VERIFY PLANS AND RISER AS
 PLANS INDICATE (2) PANEL "B"'S BEING
 LOCATED AT LOCATION, ONE BEING RELOCATED
 AND ONE BEING ABANDONED?
 RISER DOES NOT INCLUDE THE 2ND PANEL
 "B".
 PLEASE NOTE, IF CIRCUITS FROM THIS
 ABANDONED PANEL ARE BEING RELOCATED??
 215.5
  
 ** PLEASE SEE ANY POSSIBLE NOTES FROM
 OTHER REVIEWER(S) WHICH MAY AFFECT
 ELECTRICAL PLANS.
  
 ** PLEASE REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT NEW REVISED SHEETS INTO
 COMPLETE SETS FOR REVIEW AND STAMPING.
 ONE SET OF OLD/VOIDED SHEETS SHOULD BE
 SUBMITTED BACK WITH NEW SETS FOR
 REFERENCE OF OLD/VOIDED SHEETS.
  
 ** PLEASE SUBMIT THE ABOVE INFORMATION
 FOR REVIEW. IF THERE ARE ANY QUESIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2006-11-06 Cont ID  
Sent By mawillia Date 2006-11-06 Time 13:05 Rev Time 0.00
Received By mawillia Date 2006-11-06 Time 13:02 Sent To  
Notes
2006-11-06 13:10:53*****PROVISO*****
  
  
  
 RESUBMITTED PLANS WILL BE STAMPED (PASSED) ONCE ALL
 OTHER PLAN REVIEWS COMMENTS HAVE BEEN ADDRESSED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2006-06-21 Cont ID  
Sent By mwennerg Date 2006-06-21 Time 10:07 Rev Time 0.00
Received By mwennerg Date 2006-06-21 Time 10:07 Sent To  
Notes
2006-06-21 00:00:00***DENIED***
  
 1) PLEASE SEE OTHER REVIEW COMMENTS
 REGARDING FS AND FAC REQUIREMENTS FOR
 PLANS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-03-29 Cont ID  
Sent By mwennerg Date 2006-03-29 Time 10:55 Rev Time 0.00
Received By mwennerg Date 2006-03-29 Time 10:55 Sent To  
Notes
2006-03-29 00:00:00******PROVISO******
  
 1) WORK SHALL COMPLY WITH NFPA 101, 2003
 EDITION CHAPTER 36.
  
 2) IN ADDITION TO THE HEIGHT
 REQUIREMENT, ADDRESS SHALL BE
 CONTRASTING TO THE BACKGROUND.
  
 3) FOR NEW INSTALLATIONS, DUCT SMOKE
 DETECTORS SHALL CAUSE A GENERAL FIRE
 ALARM IN ACCORDANCE WITH LOCAL
 REQUIREMENTS.
  
 PLANS WILL BE STAMPED WHEN RESUBMITTED
 FOR OTHER REVIEW COMMENTS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2005-11-10 Cont ID  
Sent By mcarsill Date 2005-11-10 Time 09:51 Rev Time 0.00
Received By mcarsill Date 2005-11-10 Time 09:32 Sent To  
Notes
2005-11-10 00:00:001. DEMOLITION, RENOVATION, AND
 CONSTRUCTION TO COMPLY WITH NFPA 241.
  
 2. DEBRIS SHALL BE REMOVED FROM THE
 SITE DAILY.
  
 3. NO CUTTING OR WELDING ALLOWED WITHOUT
 APPROVAL OF THE FIRE PREVENTION BUREAU
 AND WITH COMPLIANCE WITH NFPA 51B.
  
 4. PLANS DISPLAY RELOCATED FIRE ALARM
 AND SECURITY PANEL TO BE PLACED INSIDE
 STAIRWELL. THIS ACTIVITY WILL NOT BE
 ALLOWED.
  
 5. PLEASE PROVIDE PRESCRIPTIVE STRENGTH
 REQUIREMENTS FOR ALL GUARDRAILS. LOCATED
 INFORMATION ON PAGE A-5.
  
 6. A CHANGE OF USE IS OCCURING. ALL NEW
 MERCANTILE REQUIREMENTS SHALL BE MET.
  
 7. BUILDING ADDRESS REQUIRED ON
 ELEVATION. A MINIMUM OF AT LEAST 6"
 HIGH NUMBERS ARE REQUIRED.
  
 8. SEPERATE PLANS AND PERMITS REQUIRED
 FOR FIRE ALARM SYSTEM EQUIPMENT.
  
 9.SEPERATE PLANS AND PERMITS REQUIRED
 FOR FIRE SPRINKLER SYSTEM REMODEL.
  
 10. PLEASE PROVIDE A LIFE SAFETY PLAN
 AND ILLUSTRATE EXITING RATIONALE FOR
 PROPOSED SPACE.
  
 MIKE CARSILLO, CHIEF FIRE PREVENTION
 OFFICER

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-17 Cont ID  
Sent By adarroug Date 2006-11-17 Time 11:01 Rev Time 0.00
Received By adarroug Date 2006-11-17 Time 11:01 Sent To E
Notes
2006-11-17 11:01:57TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-10-04 Cont ID  
Sent By adarroug Date 2006-10-04 Time 16:03 Rev Time 0.00
Received By adarroug Date 2006-10-04 Time 16:03 Sent To  
Notes
2006-10-19 16:19:23TO "COMM" BD#39
2006-10-04 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-12 Cont ID  
Sent By adarroug Date 2006-05-12 Time 14:18 Rev Time 0.00
Received By adarroug Date 2006-05-12 Time 14:18 Sent To  
Notes
2006-06-02 00:00:00TO "COMM" BD#34
2006-05-12 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-02-06 Cont ID  
Sent By adarroug Date 2006-02-06 Time 09:22 Rev Time 0.00
Received By adarroug Date 2006-02-06 Time 09:22 Sent To  
Notes
2006-03-06 00:00:00TO "COMM" BD#49
2006-02-06 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-02-06 Cont ID  
Sent By adarroug Date 2005-12-20 Time 09:21 Rev Time 0.00
Received By adarroug Date 2005-10-04 Time 15:25 Sent To  
Notes
2005-10-13 00:00:00TO "COMM" BD#3
2005-10-04 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-10-31 Cont ID  
Sent By pkrauss Date 2006-10-31 Time 10:57 Rev Time 0.00
Received By pkrauss Date 2006-10-31 Time 10:30 Sent To  
Notes
2006-10-31 10:57:53COMMENT BY HAROLD MOSER FROM 6/22/06 WAS ADDRESSED

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-06-22 Cont ID  
Sent By hmoser Date 2006-06-22 Time 14:11 Rev Time 0.00
Received By hmoser Date 2006-06-22 Time 14:11 Sent To  
Notes
2006-06-22 00:00:00PLAN DENIED
 PLEASE REFER TO SECTION 307.2.3#1
 AUXILIARY AND SECONDARY DRAIN SYSTEM.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-03-27 Cont ID  
Sent By hmoser Date 2006-03-27 Time 09:41 Rev Time 0.00
Received By hmoser Date 2006-03-27 Time 09:41 Sent To  
Notes
2006-03-27 00:00:00PLAN DENIED
 1) PLEASE PROVIDE MANUFACYURERS
 INSTALLATION INSTRUCTIONS ON POWER UNIT
 AND TANK CONTROLLER.
 2) PLEASE REFER TO SECTION 607.1.2
 2001FBC(M) LOCATION OF FIRE DAMPERS.
 PAGE M-1 SHOWS RETURN AIR DUCT
 PENETRATING FIRE RATED WALL.
 PLAN REVIEW BY HAROLD MOSER 561-805-6732

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2005-10-06 Cont ID  
Sent By prafter Date 2005-10-06 Time 11:57 Rev Time 1.50
Received By prafter Date 2005-10-06 Time 11:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-12-08 Cont ID  
Sent By kstevens Date 2005-12-08 Time 16:50 Rev Time 0.00
Received By kstevens Date 2005-12-08 Time 16:50 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2006-10-25 Cont ID  
Sent By mflis Date 2006-10-25 Time 14:12 Rev Time 0.00
Received By mflis Date 2006-10-25 Time 14:12 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-03-31 Cont ID  
Sent By mflis Date 2006-03-31 Time 13:13 Rev Time 0.00
Received By mflis Date 2006-03-31 Time 13:13 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-12-15 Cont ID  
Sent By mflis Date 2005-12-15 Time 14:32 Rev Time 0.00
Received By mflis Date 2005-12-15 Time 14:31 Sent To  
Notes
2005-12-15 00:00:00VERIFY ALLOWABLE PERCENTAGE OPENINGS
 ALONG NORTH ELEVATION (ALLEY SIDE) PER
 FIRE/BUILDING CODE REQ'S. -MJF


Account Summary | Usage Policy | Privacy Policy