Plan Review Details - Permit 05091687
| Plan Review Stops For Permit 05091687 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-09-24 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-09-24 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2007-09-24 09:50:37 | NEW SITE ADDRESS HAS BEEN ASSIGNED TO BUILDING 3 AS 331 | | | COURTNEY LAKES CIR , WEST PALM BEACH, FL 33401. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-03-01 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-03-01 |
Time |
15:19 |
Sent To |
|
|
| Notes |
| 2006-03-01 00:00:00 | SITE PLAN NEEDED TO ISSUE AN ADDRESS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
jjohnsto |
Date |
2007-10-16 |
Time |
13:30 |
Rev Time |
8.00 |
| Received By |
jjohnsto |
Date |
2007-10-16 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2007-10-16 13:30:07 | CONSTRUCTION SERVICES DEPARTMENT | | | 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH, | | | FLORIDA33401 | | | TEL:561-805-6713FAX: | | | 561-805-6731 | | | | | | JAMES JOHNSTON, PERMIT NO 05091687 | | | BUILDING PLAN EXAMINERII PROJECT | | | NAME COURTNEY LAKES, BLDG. 3 | | | E-MAIL:JJOHNSTON @WPB.ORG ADDRESS | | | 331 COURTNEY LAKES CIRCLE | | | DATE OCTOBER 15, 2007 | | | | | | BUILDINGPLANREVIEW | | | FLORIDA BUILDING CODE 2001 | | | | | | | | | FOR YOUR INFORMATION?. | | | THE PLANS SUBMITTED ARE DRAWN FOR THIS PROJECT?S | | | BUILDINGS TO BE CONSTRUCTED IN PHASES.PLEASE SEE THE | | | 2001 CODE RELATED SECTION 104.5.1.104.5.1.1, | | | 104.5.1.2 -NOTED HEREIN -REFERCENING,?WORK NOT | | | COMMENCED WITHIN 6 MONTHS AFTER DATE OF PERMIT ISSUANCE | | | THE PERMIT SHALL BE REVOKED AND A NEW PERMIT SHALL BE | | | ISSUED.? THE NEW PERMIT SHALL BE ISSUED UNDER THE2004 | | | BUIDING CODENOT THE 2001, REQUIRING EXISTING PLANS TO | | | BE REDRAWN IN COMPLIANCE WITH THIS CODE. | | | | | | | | | 104.5 CONDITIONS OF THE PERMIT | | | 104.5.1 PERMIT INTENT. A PERMIT ISSUED SHALL BE | | | CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND | | | NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER, OR SET | | | ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR | | | SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING | | | OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF | | | ERRORS IN PLANS, CONSTRUCTION, OR VIOLATIONS OF THIS | | | CODE. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS | | | THE WORK AUTHORIZED BY SUCH PERMIT IS COMMENCED WITHIN | | | 6 MONTHS AFTER ITS ISSUANCE, OR IF THE WORK AUTHORIZED | | | BY SUCH PERMIT IS SUSPENDED OR ABANDONED FOR A PERIOD | | | OF 6 MONTHS AFTER THE TIME THE WORK IS COMMENCED. | | | | | | | | | 104.5.1.1 IF WORK HAS COMMENCED AND THE PERMIT IS | | | REVOKED, BECOMES NULL AND VOID, OR EXPIRES BECAUSE OF | | | LACK OF PROGRESS OR ABANDONMENT, A NEW PERMIT COVERING | | | THE PROPOSED CONSTRUCTION SHALL BE OBTAINED BEFORE | | | PROCEEDING WITH THE WORK. | | | | | | | | | | | | 104.5.1.2 IF A NEW PERMIT IS NOT OBTAINED WITHIN 180 | | | DAYS FROM THE DATE THE INITIAL PERMIT BECAME NULL AND | | | VOID, THE BUILDING OFFICIAL IS AUTHORIZED TO REQUIRE | | | THAT ANY WORK WHICH HAS BEEN COMMENCED OR COMPLETED BE | | | REMOVED FROM THE BUILDING SITE. ALTERNATELY, A NEW | | | PERMIT MAY BE ISSUED ON APPLICATION, PROVIDING THE WORK | | | IN PLACE AND REQUIRED TO COMPLETE THE STRUCTURE MEETS | | | ALL APPLICABLE REGULATIONS IN EFFECT AT THE TIME THE | | | INITIAL PERMIT BECAME NULL AND VOID AND ANY REGULATIONS | | | WHICH MAY HAVE BECOME EFFECTIVE BETWEEN THE DATE OF | | | EXPIRATION AND THE DATE OF ISSUANCE OF THE NEW PERMIT. | | | | | | | | | | | | | | | | | | | | | | | | | | | A 1804.2.2SOIL TEST REPORT | | | THE REPORT SUBMITTED IN 2003 REFERENCES A CONCLUSION OF | | | BEARING CAPACITY | | | FOR A SINGLE STORY STRUCTURE. WHERE THE BEARING | | | CAPACITY OF THE SOIL IS | | | NOT DEFINITELY KNOWN OR IS IN QUESTION, THE BUILDING | | | OFFICIAL MAY REQUIRE | | | LOAD TESTS OR OTHER ADEQUATE PROOF AS TO THE | | | PERMISSIBLE SAFE BEARING | | | CAPACITY AT THAT PARTICULAR LOCATION.TO DETERMINE THE | | | SAFE BEARING | | | CAPACITY OF SOIL, IT SHALL BE TESTED AT SUCH LOCATIONS | | | AND LEVELS AS | | | CONDITIONS WARRANT, BY LOADING AN AREA NOT LESS THAN 4 | | | SQ FT (0.37 M{2}) | | | TO NOT LESS THAN TWICE THE MAXIMUM BEARING CAPACITY | | | DESIRED FOR USE.SUCH | | | DOUBLE LOAD SHALL BE SUSTAINED BY THE SOIL FOR A PERIOD | | | OF NOT LESS THAN | | | 48 HOURS WITH NO ADDITIONAL SETTLEMENT TAKING PLACE, IN | | | ORDER THAT SUCH | | | DESIRED BEARING CAPACITY MAY BE USED.SUBSOIL | | | CONDITIONS SHALL BE | | | EXAMINED AT THE EXPENSE OF THE OWNER, WHEN DEEMED | | | NECESSARY BY THE | | | BUILDING OFFICIAL. | | | COMMENTPLEASE FURNISH A SOIL TEST REPORT APPLICABLE | | | FOR THE THREE BUILDINGS ?FIVE STORIES EACH TO BE | | | CONSTRUCTED WITH THE RECOMMENDATIONS FOR PROPER GROUND | | | PREPARATION TO ACHIEVE THE DESIRED BEARING CAPACITY | | | FOR EACH BUILDING. | | | TWO COPIES OF THIS REPORT SHALL BE INCLUDED FOR EACH | | | SEPARATE BUILDING PROJECT.THE REPORT IS TO ENCOMPASS | | | THE THREE BUILDINGS, TWO COPIES FOR EACH BUILDING | | | | | | A-1 FBC105.11SOIL TREATMENT | | | COMMENTIDENTIFY THE CHEMICAL SOIL TREATMENT TO BE | | | USED IN THE SLAB NOTES SHEET APS3.21 | | | | | | | | | | | | B PRODUCT APPROVALS | | | COMMENTTHE FLORIDA PRODUCT APPROVAL COVER SHEET | | | SHALL INCLUDE THE APPROVAL INFORMATION FOR THE PRODUCT | | | SELECTED.SEE ATTACHED SAMPLE INCLUDED. | | | THE DESIGNER OF RECORD SHALL REVIEW EACH APPROVAL?S | | | SPECIFICATION PACKETAND ACKNOWLEDGE SAME ON THE | | | APPROVAL COVER SHEETBY NAME DATE AND STATEMENT OF | | | ACCEPTANCE | | | | | | | | | B-1 WINDOWS / DOORS PRODUCT APPROVALS | | | WPB ADMINISTRATIVE CODE 106.3 REGULATED BY DCA RULE | | | 9B-72FLORIDA PRODUCT APPROVAL | | | SUBMIT TWO COPIES OF EACH APPROVAL WITH FLORIDA PRODUCT | | | APPROVAL COVER SHEET THE ARCHITECT?S / ENGINEER?S | | | SIGNATURE AS APPLICABLE, STATING ?TO THE BEST OF THEIR | | | KNOWLEDGE THE PRODUCT APPROVAL COMPLIES WITH THE PLANS | | | AND SPECIFICATIONS.SEE:WEB SITE | | | WWW.FLORIDABUILDING.COM | | | NOTE: SEE DIVISION FACTOR TO BE USED IN DESIGN PRESSURE | | | BY LEGACYFPA | | | COMMENT-FOR YOUR INFORMATION | | | | | | | | | B-2 SUBMIT PRODUCT APPROVALS WITH FLORIDA PRODUCT | | | APPROVAL COVER | | | PAGE FOR THE FOLLOWING | | | OPERABLE WINDOWS | | | FIXED GLASS | | | MULLION TUBES | | | PANEL WALLS | | | STORE FRONT GLAZING SYSTEM | | | ALUMINUM OUT -SWING DOORS | | | HOLLOW METAL DOORS | | | TRUSS ANCHORS | | | ROOFINGCOMPONENTS | | | SHUTTERS | | | SKYLIGHTS | | | OVERHEAD GARAGE DOOR | | | COMMENT-PLEASE COMPLY | | | | | | B-3 3RD REQUEST ? | | | COMMENT-FURNISH THE FOLLOWING PRODUCT REPORTS | | | TRACO OPERABLE WINDOWSNON IMPACT 0? TO 30?,LARGE | | | MISSLE 30? TO 60? | | | TRACO FIXED WINDOWS | | | MULLIONS | | | EXTERIOR HOLLOW METAL DOORS | | | EXTERIOR GLAZED DOORS | | | EXTERIOR LOUVER DOORS | | | EXTERIOR RAILINGS, ENGINEERING REQUIRED | | | LOUVERS,NO REPORT SUBMITTED | | | ROOF ASSEMBLIES, DENSE DECK, ATTACHMENTS, INSULATION, | | | UNDERLAYMENT,ROOF TILE,ROOF SYSTEM | | | IDENTIFY EACH COMPONENT TO BE USED | | | RATIONAL ANALYSIS FOR ZONE 2 AND THREE | | | EFIS WALL SYSTEM (IF USED) | | | 5/8? AQUA ROCK SHEATHING | | | ROLL UP DOOR | | | WOOD BASE STRUCTURAL PANELSFBC 2315.1.11 | | | | | | | | | B-4 PROVIDE DESIGN LOADS ON ALL WINDOW , DOOR, | | | COMPONENTS ON SCHEDULE | | | 2405.3.2.1 THE DESIGN LOADS SHALL BE COMBINED | | | AS FOLLOWS: | | | | | | 1. NEGATIVE WIND LOAD - DEAD LOAD | | | 2. POSITIVE WIND LOAD + DEAD LOAD | | | 3. DEAD LOAD + 1/2 POSITIVE WIND LOAD | | | WIND LOADS SHALL BE DETERMINED FROM 1606. THE DEAD LOAD | | | FOR THE GLASS IN LB/SQ FT SHALL BE TAKEN AS THE TOTAL | | | THICKNESS OF THE GLASS PANES AND PLIES IN INCHES X 13. | | | THIS APPLIES FOR GLASS 30 DEGREES OR LESS FROM | | | HORIZONTAL. FOR OTHER SLOPES THE GLASS DEAD LOAD IS | | | EQUAL TO THIS VALUE TIMES THE COSINE OF ITS SLOPE FROM | | | HORIZONTAL. | | | | | | | | | B-5 FBC2411.3.1.4 THE ARCHITECT OR PROFESSIONAL | | | ENGINEER OF RECORD SHALL BE | | | REQUIRED TO SPECIFY THE DESIGN WIND PRESSURE, | | | DETERMINED IN ACCORDANCE | | | WITH CHAPTER 16 (HIGH VELOCITY HURRICANE ZONES), | | | FOR ALL GARAGE DOORS, | | | SKYLIGHTS OPERATIVE WINDOWS AND FIXED GLAZING. | | | THE DESIGN WIND PRESSURE | | | FOR EACH COMPONENT OF THE EXTERIOR BUILDING | | | SURFACE, SHALL BE | | | INCORPORATED INTO THE BUILDING DESIGN DRAWING SO | | | AS TO ALLOW THE | | | RESPECTIVE MANUFACTURER TO SIZE THE PREFABRICATED | | | ASSEMBLY FOR THE | | | PROPER WIND PRESSURES. | | | COMMENTPLEASE PROVIDE THIS INFORMATION ON THE | | | ELEVATIONS | | | | | | | | | C 105.13 THRESHOLD BUILDING | | | 105.13.2 THE SPECIAL INSPECTOR SHALL INSPECT THE | | | SHORING AND RE-SHORING | | | FOR CONFORMANCE TO THE SHORING AND RE-SHORING PLANS | | | SUBMITTED TO THE | | | ENFORCING AGENCY.A FEE SIMPLE TITLE OWNER OF A | | | BUILDING WHICH DOES NOT | | | MEET THE MINIMUM SIZE, HEIGHT, OCCUPANCY, OCCUPANCY | | | CLASSIFICATION OR | | | NUMBER-OF-STORIES CRITERIA WHICH WOULD RESULT IN | | | CLASSIFICATION AS A | | | THRESHOLD BUILDING UNDER ?553.71(7) FLORIDA | | | STATUTES, MAY DESIGNATE | | | SUCH BUILDING AS A THRESHOLD BUILDING, SUBJECT TO | | | MORE THAN THE MINIMUM | | | NUMBER OF INSPECTIONS REQUIRED BY THE FLORIDA | | | BUILDING CODE, BUILDING. | | | COMMENTPLEASE FURNISH A SHORING AND RE-SHORING PLAN | | | | | | | | | | | | D SITE PLAN AND ASSOCIATED COMPONENTS REQUIRED3RD | | | REQUEST(NOT INCLUDED) | | | | | | COMMENTPLEASE FURNISH A SEPARATE SITE PLAN FOR | | | BUILDING NO III. INCLUDE THIS SITE PLANWITHTHE | | | ARCHITECTURAL DRAWINGS FOR THE FOLLOWING | | | (A) PARKING SPACES LOCATED OUTSIDE AND UNDERNEATH THE | | | BUILDING. CURBING, RAMPS, ACCESSIBLE ISLES FOR THE | | | HANDICAP, SIGNAGE, SIDEWALKS, CURB CUTS, PEDESTRIAN | | | CROSS WALKS (B) HANDICAP SPACES LOCATED OUTSIDE AND | | | UNDERNEATH THE BUILDING PERIMETER. IDENTIFY ALL | | | HANDICAP PARKING SPACES AS DEFINED BY THEAMERICANS | | | WITH DISABILITIES FLORIDA BUILDING CODE CHAPTER 11 | | | PART BANSIA117-1 ANDFAIR HOUSING ACT GUIDELINES | | | (C) IDENTIFY THE ACCESSIBLE ROUTE AS DEFINED BY | | | THE AMERICANS WITH DISABILITIES- FLORIDA BUILDING | | | CODE CHAPTER 11 AND FAIR HOUSING ACT GUIDELINES | | | (D) IDENTIFY VAN ACCESSIBLE PARKING SPACES UNDER | | | BUILDING AND EXTERIOR IN COMPLIANCE WITH | | | THE AMERICANS WITH DISABILITIES FLORIDA BUILDING CODE | | | CHAPTER 11ANDFAIR HOUSING ACT | | | GUIDELINES, NOTE PARKING SPACES FOR VANS SHALL HAVE | | | VERTICAL CLEARANCE OF 98? | | | (E) ONE ACCESSIBLE ROUTE FAIR HOUSING, FROM THE | | | BOUNDARY SITES PUBLIC TRANSPORTATION STOP TO AN | | | ACCESSIBLE BUILDING ENTRANCE. CHAPTER 11, PART B ? | | | ANSI A117.1,502.6 | | | | | | E FBC411.2 AUTOMOBILE PARKING ARAGES | | | COMMENTPLEASE VERIFY OPEN OR ENCLOSED WITH THE CODE | | | SECTIONS PROVIDED HEREIN | | | | | | 411.2.1 AUTOMOBILE PARKING GARAGES SHALL BE CLASSIFIED | | | AS EITHER OPEN, AS DEFINED IN 411.3, OR ENCLOSED AND | | | SHALL MEET THE APPROPRIATE CRITERIA OF 411.3 OR 411.4. | | | | | | FBC411.3ENCLOSED PARKING GARAGES | | | | | | FBC 411.4.1 ENCLOSED AUTOMOBILE PARKING GARAGES AND | | | PORTIONS THEREOF WHICH DO NOT MEET THE DEFINITION OF | | | OPEN PARKING GARAGES SHALL BE LIMITED TO THE ALLOWABLE | | | HEIGHTS AND AREAS SPECIFIED IN TABLE 500 FOR GROUP S | | | BUILDINGS. | | | | | | 411.4.2 A MECHANICAL VENTILATION SYSTEM FOR THE | | | REMOVAL OF THE PRODUCTS OF COMBUSTION SHALL BE | | | PROVIDED IN ENCLOSED AUTOMOBILE PARKING GARAGES. THE | | | MECHANICAL SYSTEM SHALL BE CAPABLE OF PROVIDING AT | | | LEAST 6 AIR CHANGES PER HOUR FOR EACH LEVEL. UNDER | | | NORMAL USE THE VENTILATION OF THE | | | ENCLOSED AUTOMOBILE PARKING GARAGE SHALL COMPLY WITH | | | THE VENTILATION REQUIREMENTS OF 411.5. | | | 411.2.2 THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN | | | VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT BE LESS | | | THAN 7? | | | | | | FBC 411.3 OPEN PARKING GARAGES411.3.1 | | | OPEN AUTOMOBILE PARKING GARAGES WITH ROOF PARKING MAY | | | BE CONSTRUCTED TO THE ALLOWABLE HEIGHTS AND AREAS | | | SPECIFIED IN TABLE 411.3.1. TO BE CONSIDERED OPEN, THE | | | GARAGE SHALL MEET THE REQUIREMENTS OF411.3.2, | | | 411.3.3 AND411.3.4. | | | | | | 411.3.2 THE EXTERIOR AND INTERIOR WALLS OF THE GARAGE | | | SHALL BE DESIGNED IN ACCORDANCE WITH ONE OF THE | | | FOLLOWING: | | | | | | 1. AT LEAST 50 PERCENT OF THE CLEAR HEIGHT BETWEEN | | | FLOORS SHALL BE OPEN TO THE ATMOSPHERE FOR THE FULL | | | LENGTH OF AT LEAST TWO EXTERIOR WALLS, EXCLUDING | | | REQUIRED STAIR AND ELEVATOR WALLS AND STRUCTURAL | | | COLUMNS. INTERIOR WALL LINES AND COLUMN LINES SHALL BE | | | AT LEAST 20 PERCENT OPEN AND UNIFORMLY DISTRIBUTED, | | | OR | | | | | | 2. THE EXTERIOR WALLS OF THE STRUCTURE SHALL HAVE | | | UNIFORMLY DISTRIBUTED OPENINGS ON TWO OR MORE SIDES | | | TOTALING NO LESS THAN 40 PERCENT OF THE BUILDING | | | PERIMETER. THE AREA OF SUCH OPENINGS IN THE EXTERIOR | | | WALLS ON EACH LEVEL SHALL BE AT LEAST 20 PERCENT OF | | | THE TOTAL PERIMETER WALL AREA OF EACH LEVEL. INTERIOR | | | WALL LINES AND COLUMN LINES SHALL BE AT LEAST 20 | | | PERCENT OPEN AND UNIFORMLY DISTRIBUTED. | | | | | | 411.3.3 THE DISTANCE FROM ANY POINT ON ANY FLOOR LEVEL | | | TO AN OPEN EXTERIOR WALL FACING ON A STREET, OR TO | | | OTHER PERMANENTLY MAINTAINED OPEN SPACE AT LEAST 20 | | | FT (6096 MM) WIDE EXTENDING FULL WIDTH TO A STREET, | | | SHALL NOT EXCEED 200 FT (61 M). | | | | | | 411.3.4 GARAGES WITHIN 10 FT (3048 MM) OF A COMMON | | | PROPERTY OR BUILDING LINE SHALL BE PROVIDED WITH AN | | | ENCLOSURE WALL ALONG THE LINE OF NOT LESS THAN 1-HOUR | | | FIRE RESISTANCE WITHOUT OPENINGS THEREIN, EXCEPT DOOR | | | OPENINGS MEETING THE REQUIREMENTS OF705.1.3 SHALL BE | | | PERMITTED. | | | | | | F APA6.40, A6.41,A6.45 | | | COMMENTPLEASE IDENTIFY WINDOWS, DOORS, OVERHEAD | | | DOORS ON THE BUILDING ELEVATIONS TO CORRESPOND WITH | | | THE INFORMATION PROVIDED ONA9.03 | | | | | | G TRASH CHUTE ACCESS DOORS | | | COMMENT PLEASE IDENTIFY THE ACCESS CHUTE DOOR ON THE | | | DOOR SCHEDULE WITH NOTE E SHEET A8.20 | | | | | | H ARCHITECTURAL TRIM1404.1.1ABOVE 3 STORIES OR 40 | | | FT | | | COMMENT-A7.02IDENTIFY THE FASTENING HARDWARE TO | | | BE USED IN SECURING THE FOAM TRIM TO THE BUILDING | | | EXTERIOR SURFACE | | | | | | I SHEET GN-A1.05,GN-A1.06 | | | COMMENTPLEASE PROVIDE LEGIBLE INFORMATION ON | | | THESE SHEETS | | | | | | J 11-4.10 ELEVATORS | | | 11-4.10.9 FLOOR PLAN OF ELEVATOR CARS. THE FLOOR AREA | | | OF ELEVATOR CARS SHALL PROVIDE SPACE FOR WHEELCHAIR | | | USERS TO ENTER THE CAR, MANEUVER WITHIN REACH OF | | | CONTROLS, AND EXIT FROM THE CAR. ACCEPTABLE DOOR | | | OPENING AND INSIDE DIMENSIONS SHALL BE AS SHOWN IN | | | FIGURE 11-22. THE CLEARANCE BETWEEN THE CAR PLATFORM | | | SILL AND THE EDGE OF ANY HOIST WAY LANDING SHALL BE NO | | | GREATER THAN 1-1/4 INCHES (32 MM). | | | COMMENTPROVIDE A FLOOR PLAN OF THE ELEVATOR CAB | | | UTILIZING THIS SECTION OF THE ADACHAPTER 11 | | | | | | K THERE IS A DISCREPANCY IN BETWEEN THE STRUCTURAL AND | | | ARCHITECTURAL DRAWINGS | | | SHEETAP-S3.31ATHIS SHEET DETAILS THE ELEVATOR | | | SHAFT WITH A TRASH CHUTE. THE ELEVATOR LANDINGIS | | | RAISED 3?-6? OFF THE FINISHED FLOOR. THE ACCESSIBILITY | | | PATH FROM THE ELEVATOR TO THE EXTERIOR IS BLOCKED | | | BY A WALL. THERE IS AN ADDITIONAL WALL BLOCKING THE | | | STAIR DRAWN ON THE PLAN. THE SPACE CONTAINING THE | | | DUMPSTER HAS A FLOOR ELEVATION OF 3?6? LEADING TO THE | | | EXTERIOR. THE REQUIRED DIMENSIONS FOR CONSTRUCTION ARE | | | MISSING IN MANY AREAS. | | | | | | SHEET AP-A5.40THIS SHEET DETAILS THE ELEVATOR | | | LANDING AT THE ELEVATION OFTHE FINISHED FLOOR BUT, | | | HAS STAIRS DRAWN. THE MATCH LINE DOES NOT MATCH THE | | | LOCATION DRAWN ON SHEETS3.31A | | | COMMENTIF THISBUILDING IS BEING SUBMITTED FOR | | | PERMITTING IN TWO PHASES, ALL INFORMATION MUST BE | | | INCLUDED WITH A DESCRIPTION OF EACH PHASE. ALL EXIT | | | ACCESS MUST BE CONSIDERED CHAPTER 11, ADA FAIR HOUSING | | | ACT.LIFE SAFETY ISSUES MUST BE ADDRESSED. | | | THIS PLAN SHOULDBE DRAWN BY THE ARCHITECT AND | | | ENGINEER TO ADDRESS THE PROJECT BEING CONSTRUCTED IN | | | TWO PHASES WITH ADEQUATE COMMUNICATION REFERENCING | | | COMPLIANCE OF ALL APPLICABLE CODES | | | | | | L WHAT IS THE PURPOSE OF THE HATCHED AREA ON THE ?B? | | | SECTION FLOOR PLANS BEGINNING WITH SHEET APS3.32A | | | ???? | | | | | | M A SECTION THRU THE BUILDING REFERENCING THE | | | FOUNDATION, WALLS, BALCONIES, BEAMS, ROOF, PARAPET HAVE | | | NOT BEEN INCLUDED.SEE SHEET AP.701 BLDG. 2 FOR | | | INFORMATION REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-09 |
Time |
15:05 |
Rev Time |
9.99 |
| Received By |
jwitmer |
Date |
2007-02-09 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2007-02-09 15:10:07 | | | | | | | | | | PERMIT: 05091687 BLDG# 3 | | | ADD:XXX N CONGRESS | | | 74-43-43-20-00-000-3010 | | | CONT: E. A. LANDERS | | | TEL: (305)823-3938 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | COURTNEY LAKES APARTMENTS, LLC | | | | | | ARCH: FORUM ARCHITECTURE & INTERIOR DESIGN | | | (407)830-1400 | | | STRUC: ROBERT PLOWFIELD & ASSOC | | | (407)657-6657 | | | 2ND REVIEW | | | ACTION: DENIED | | | | | | ***IMPORTANT*** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH A | | | DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | NOTE NOC WILL BE NULL & VOID 90 DAYS | | | AFTER RECORDING AT THE CLERK OF THE | | | COURTS OFFICE IF WORK HAS NOT STARTED. | | | FL S S 713.13(2). | | | | | | 2) THIS COMMENT WAS PARTIALLY SATISFIED, FOR THE WHOLE | | | OF THE PROJECT (3 BUILDINGS) | | | THREE SIGNED & SEALED REPORTS WERE SUBMITTED TO THE | | | CITY. THIS WILL SATISFY THE REQUIREMENT | | | TO HAVE (1 ) REPORT WITH EACH PERMIT OR BUILDING. THE | | | NEED STILL ARISES TO HAVE AT LEAST ONE SIGNED/ SEALED | | | ORIGINAL FOR THE CONTRACTOR AS WELL AS THE THRESHOLD | | | INSPECTOR. | | | AN ADDITIONAL 2 ORIGINAL SOILS REPORTS SIGNED & SEALED | | | SHALL BE REQUIRED. | | | FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3-4) COMPLIED. | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 6)FL S. S. 553.71(7) " THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPANCY | | | CLASSIFICATION AS DENIED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | STRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL INSPECTION PLAN | | | PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE | | | ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESH- | | | OLD BUILDING. THE PURPOSE OF THE STRUCTURAL INSPECTION | | | PLAN IS TO PROVIDE SPECIFIC INSPECTION PROCEDURES AND | | | SCHEDULES | | | SO THAT THE BUILDING CAN BE ADEQUATELY | | | INSPECTED FOR COMPLIANCE WITH THE | | | PERMITTED DOCUMENTS. | | | | | | 7) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 8) COMPLIED. | | | | | | 9A) 2ND REQUEST, CONTACT LILI URSA FOR ADDRESSING | | | REQUIREMENTS @ (561)822-1239 | | | | | | 9B) 2ND REQUEST, PLEASE PROVIDE A COPY OF THE NEW PLAT, | | | LOT | | | HAS BEEN SUBDIVIDED. | | | | | | 9C) 2ND REQUEST, ON ALL (3) PERMIT APPLICATIONS CORRECT | | | THE PROPERTY CONTROL NUMBER TO | | | THE NEW LOT. | | | | | | 9D) PROVIDE A SITE PLAN WITH LOCATION OF THE PROPOSED | | | STRUCTURES WITH DIMENSIONS | | | FOR TABLE 600 ISSUES.A2.01 HAS NO DIMENSIONS! RESPONSE | | | COMMENTS ARETO SEE CIVIL PLANS ,NO CIVIL PLANS PROVIDED | | | IN THIS SET OF PLANS. | | | | | | 10A-K) COMPLIED. | | | | | | 11) SHEET A1.05 | | | | | | 11A & B) COMPLIED. | | | | | | 12)SITE PLAN A2.01 | | | NEW COMMENT THAT DEALS WITH THE OVER ALL PARKING SPACES | | | AND THE REQUIRED NUMBER OF ACCESSIBLE SPACES. THE PLANS | | | INDICATE A TOTAL OF 912 SPACES WHERE AS IT APPEARS TO | | | BE 1008 PARKING SPACES IF THIS IS TRUE THE REQUIRED | | | NUMBER OF ACCESSIBLE SPACES WOULD BE 21. | | | CHAPTER 11 PART B- 4PARKING AND PASSENGER LOADING: | | | ACCESSIBLE PARKING ON A ROUTE ACCESSIBLE TO WHEELCHAIRS | | | FOR AT LEAST 2% OF THE COVERED DWELLING UNITS: | | | ACCESSIBLE VISITOR PARKING SUFFICIENT TO PROVIDE ACCESS | | | TO GRADE LEVEL ENTRANCES OF COVERED MULTIFAMILY | | | DWELLINGS; AND ACCESSIBLE PARKING AT FACILITIES (E.G., | | | SWIMMING POOLS) THAT SERVE ACCESSIBLE BUILDINGS. | | | | | | 12A) 2ND REQUEST, THERE ARE NO CIVIL PLANS INCORPORATED | | | INTO THIS SET OF PLANS TO REVIEW FOR ACCESSIBILITY. | | | ACCESSIBLE ROUTE: FAIR HOUSING AT LEAST ONE ACCESSIBLE | | | ROUTE SHALL BE | | | PROVIDED WITHIN THE BOUNDARY OF THE SITE FROM PUBLIC | | | TRANSPORTATION STOPS, | | | ACCESSIBLE PARKING SPACES, PASSENGER LOADING ZONES IF | | | PROVIDED, AND PUBLIC | | | STREETS OR SIDEWALKS, TO AN ACCESSIBLE BUILDING | | | ENTRANCE. | | | | | | 12B)2ND REQUEST, THERE ARE NO CIVIL PLANS INCORPORATED | | | INTO THIS SET OF PLANS TO REVIEW FOR ACCESSIBILITY. | | | THE SITE PLAN DOES NOT PROVIDE ANY INFORMATION AS TO | | | CURB CUTS, PEDESTRIAN | | | CROSS WALKS, ETC. RESPONSE IS THE CIVIL ENGINEER IS TO | | | RESPOND? WHERE? | | | | | | 12B)(1) PLEASE PROVIDE INFORMATION WHICH ACCESSIBLE | | | PARKING SPACES WILL BE THE VAN ACCESSIBLE SPACES? | | | CHAPTER 11 PART B ANSI A117-1 502.5 PARKING SPACESFOR | | | VANS SHALL HAVE A VERTICAL CLEARANCE OF 98" MINIMUM AT | | | THE SPACE AND ALONG THE VEHICULAR ROUTE THERETO. | | | | | | 12B)(2) PLEASE PROVIDE SIGNAGE FOR ALL ACCESSIBLE | | | PARKING SPACES . CHAPTER 11 PART B ANSI A117.1502.6. | | | | | | 13) SHEET A5.40: | | | | | | 13A-C) COMPLIED. | | | | | | 13D) TRASH TERMINATION ROOM NO RATING, THE IS NO WALL | | | TAG IDENTIFYING THE HOURLY WALL RATING OF THE WALL? | | | TABLE 705.1.2. | | | | | | 13E) FIRE PUMP ROOM NO RATING OF WALL, NFPA | | | 20:5.1.12.1.1REQUIRES A 2 HR WALL RATING, DOOR | | | PROTECTIVE OF1 ? HR. | | | | | | 13F-I) COMPLIED. | | | | | | 14) COMPLIED. | | | | | | 15) SHEET A5.41: | | | | | | 15A) 2ND REQUEST, TRASH ROOM DETAIL 1& 2 OF A8.20 THE | | | DETAIL IS MISSING THE ENCLOSURE TO THE BOTTOM OF THE | | | CHUTE ENCLOSURE .705.2.4.2ALL OPENINGS INTO THE SHAFT | | | ENCLOSURE, | | | INCLUDING THOSE FROM ACCESS ROOMS AND TERMINATION | | | ROOMS, SHALL BE PROTECTED IN ACCORDANCE WITH TABLE | | | 705.1.2.SUCH OPENING PROTECTIVE SHALL BE SELF-CLOSING | | | OR AUTOMATIC-CLOSING UPON DETECTION OF SMOKE, EXCEPT | | | THAT THE OPENING PROTECTIVE BETWEEN THE SHAFT AND THE | | | TERMINATION ROOM MAY BE CLOSED BY A HEAT-ACTIVATED | | | DEVICE. | | | PLEASE PROVIDE INFORMATION ON THE TRASH CHUTE SHOP | | | DRAWINGS, WALL THICKNESS OF CHUTE, THE | | | SELF CLOSING DEVICES, LOCATION OF SPRINKLER HEADS IN | | | THE CHUTE. | | | | | | 15B) THE TRASH REFUSE ROOM DETAIL 4 / A8.20 INDICATES | | | THE 2 HR RATING ON THE FRONT & BACK WALL NOT THE SIDE | | | WALLS? NOR RATING OF THE ACCESS ROOM WALLS? TABLE | | | 705.1.2 & 705.2.4.3. | | | | | | 15C) NEW COMMENT:SHEET A5.43 INDICATES AN ELEVATOR | | | DETAIL 2 /A8.10 , THIS ELEVATOR MACHINE ROOM DOES NOT | | | INDICATE WALL OR DOOR RATINGS? | | | | | | 15D) NEW COMMENT: SHEET A5.44 ROOF ACCESS FROM | | | STAIRWELL# 2 PLANS DO NOT IDENTIFY THIS DOORWAY NOR | | | RATING. | | | | | | 15E) NEW COMMENT: SHEET A5.44 STAIRWELL ACCESS TO ROOF. | | | SEE 1008 SUCH STAIRWAY SHALL BE MARKED AT STREET AND | | | FLOOR LEVELS WITH A SIGN INDICATING THAT IT CONTINUES | | | TO THE ROOF. | | | | | | 15F) NEW COMMENT: SHEET A7.01WALL SECTION# 2& A7.02 | | | WALL SECTION# 3, DETAIL# 12/ A7.10 INDICATES THE USE OF | | | WHAT APPEARS TO BE EFIS WALL SYSTEMS, THERE IS A WALL | | | IDENTITY TAG W1-14 , NO SUCH TAG ON SHEET A1.04? | | | | | | 15G) NEW COMMENT: SHEET A7.02 KEY NOTE # 10 NOTES SEE | | | STRUCTURAL DRAWINGS FOR ROOF TRUSS ANCHORAGE, NO | | | TRUSSES NEAR THE NOTE, WHY IS THE BATT INSULATION ON | | | THE FLOOR? | | | | | | 15H) NEW COMMENT SHEET A7.02NOTE # 29 INDICATES THE USE | | | OF FOAM BAND TRIM ON THE EXTERIOR OF THE BUILDING. SEE | | | 1404.1.1.ARCHITECTURAL TRIM ON BUILDINGS OF TYPE I, | | | II AND IV | | | CONSTRUCTION NOT MORE THAN THREE STORIES OR 40 FT | | | (12.2 M) HIGH MAY BE OF | | | TYPE VI CONSTRUCTION, AND MAY BE OF TYPE VI | | | CONSTRUCTION ON ALL BUILDINGS | | | OF TYPE III, V AND VI CONSTRUCTION.TRIM SHALL BE | | | SECURED TO THE WALL | | | WITH METAL OR OTHER APPROVED BRACKETS OR FASTENERS. | | | WHEN ARCHITECTURAL | | | TRIM IS LOCATED ALONG THE TOP OF EXTERIOR WALLS, IT | | | SHALL BE COMPLETELY | | | BACKED BY THE EXTERIOR WALL AND SHALL NOT EXTEND OVER | | | THE TOP OF EXTERIOR | | | WALLS. | | | | | | 15I) NOTE# 39 DEALS WITH ROOF TILE RIDGE AND EDGE CAPS, | | | IT APPEARS TO BE MISPLACED. PLEASE PROVIDE RIDGE AND | | | HIP ATTACHMENT METHODS, IF NOT COVERED UNDER THE | | | PRODUCT APPROVALS SEE ROOFING STANDARD FRSA/RTI | | | 07320.. | | | | | | | | | 16) SHEET A7.10. | | | | | | 16A) COMPLIED. | | | | | | 16B) SEE 15E & 15F. | | | | | | 16C) COMMENT# 15H . 2ND REQUEST, | | | THIS SAME SECTION INDICATES USE OF | | | FOAM TRIM ON THE EXTERIOR OF THE | | | BUILDING ABOVE 40'.1404.1.1 | | | ARCHITECTURAL TRIM ON BUILDINGS OF TYPE | | | I, II AND IV CONSTRUCTION NOT MORE THAN | | | THREE STORIES OR 40 FT (12.2 M) HIGH MAY | | | BE OFTYPE VI CONSTRUCTION, AND MAY BE | | | OF TYPE VI CONSTRUCTION ON ALL BUILDINGS | | | OF TYPE III, V AND VI CONSTRUCTION. | | | TRIM SHALL BE SECURED TO THE WALL WITH | | | METAL OR OTHER APPROVED BRACKETS OR | | | FASTENERS.WHEN ARCHITECTURAL TRIM IS | | | LOCATED ALONG THE TOP OF EXTERIOR WALLS, | | | IT SHALL BE COMPLETELY BACKED BY THE | | | EXTERIOR WALL AND SHALL NOT EXTEND OVER | | | THE TOP OF EXTERIOR WALLS. | | | | | | | | | 17) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 18) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) OPERABLE WINDOWS | | | FL 3485TRACO TR-6800 -OK | | | FL 3044.3TRACO HS-HC 65 NON-IMPACT WINDOW | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | FL 3044.4TRACO HS-AW 55NON-IMPACT WINDOW | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | FL 3044.5TRACO HS-AW55 NON-IMPACT WINDOW | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | | | | B) FIXED WINDOWS | | | FL 3487TRACOTR-3800 - OK | | | FL 632KAWNEER EXPIRED NOA NON-IMPACT | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | | | | C) MULLIONS MAY OR MAY NOT BE INCLUDED IN THE PRODUCT | | | APPROVALS | | | | | | D) EXTERIOR HOLLOW METAL DOORS | | | FL3078 AMWELD DENIED LOW PRESSURES SINGLE & | | | PAIRS | | | | | | E) EXTERIOR GLAZED DOORS | | | FL 3038TRACO 03-0829.06 SMALL MISSILE ONLY, NO | | | PRESSURE TEST - DENIED | | | FL 3038.3TRACO 03-0422.04 TR-8910 SMALL | | | MISSILE TEST NO PRESSURE TEST - DENIED | | | FL 3038.4TRACO 03-0422.04 TR-8910 LARGE | | | MISSILE HIGHLIGHT ANCHOR FASTENING SCHEDULE MAY COMPLY | | | FL3477TRACO TR-8300SLIDING GLASS DOOR | | | NON-IMPACTREQUIRES 0-30' LARGE MISSILE, 30'-60' SMALL | | | MISSILE - DENIED | | | | | | F) EXTERIOR LOUVERED DOORS NO REPORT SUBMITTED | | | | | | G) EXTERIOR RAILINGS- WILL ONLY NEED ENGINEERING NOT A | | | PRODUCT APPROVAL | | | | | | H) LOUVERS NO REPORT SUBMITTED. | | | | | | I) TRUSS ANCHORS NO REPORT SUBMITTED. | | | | | | J) ROOF ASSEMBLIES INCLUDING DENSE DECK, INSULATION, | | | UNDERLAYMENT, ROOF TILE AND ATTACHMENT METHODS. FL 1559 | | | SINGLE PLY ROOF SYSTEMS- HIGHLIGHT WHICH SUB-SYSTEM TO | | | BE USED. | | | NOTE ZONES 2 & 3 MAY REQUIRE ENHANCED FASTENING | | | PROVIDE RATIONAL ANALYSIS BY QUALIFIED PROFESSIONAL | | | | | | K) EFIS WALL SYSTEMS IF USED | | | | | | L)5/8" FIBER TOUGH AQUA ROCK SHEATHING | | | | | | M ) PRE-MANUFACTURED ROOF A/C STANDS- OK | | | | | | N) ROLL UP DOOR - NO REPORT SUBMITTED | | | | | | O) DENSE DECK- MAY BE INCORPORATED IN A PRODUCT | | | APPROVAL | | | | | | P) ROOF TILE - NO REPORT SUBMITTED- CIRCLE OR HIGHLIGHT | | | WHAT ANCHOR METHOD TO INSTALLROOF TILE | | | | | | 19) IMPACT GLASS IS SPECIFIED, COMPLIED. | | | | | | 20)IMPACT GLASS IS SPECIFIED, COMPLIED. | | | | | | | | | 21)IMPACT GLASS IS SPECIFIED, COMPLIED. | | | | | | | | | 22- 29) COMPLIED | | | | | | NOTE: CALCULATED VALUE: $ 10,848,462.00/144,666 SQ | | | FT | | | | | | ADDITIONAL COMMENTS MAY APPEAR ON THE | | | NEXT REVIEW NOT COVERED FROM THE FIRST | | | REVIEW DUE TO THE COMMENT RESPONSE OR | | | ADDITIONAL INFORMATION NOT PROVIDED | | | UNDER THE FIRST REVIEW. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | COURTNEY LAKES BLD.# 3 REV. (2).DOC |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-06 |
Time |
16:54 |
Rev Time |
8.00 |
| Received By |
jwitmer |
Date |
2006-02-06 |
Time |
16:53 |
Sent To |
|
|
| Notes |
| 2006-02-06 00:00:00 | PERMIT: 05091687 BLDG# 3 | | | ADD:XXX N CONGRESS | | | 74-43-43-20-00-000-3010 | | | CONT: E. A. LANDERS | | | TEL: (305)823-3938 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | COURTNEY LAKES APARTMENTS, LLC | | | | | | ARCH: FORUM ARCHITECTURE & INTERIOR DESIGN | | | (407)830-1400 | | | STRUC: ROBERT PLOWFIELD & ASSOC | | | (407)657-6657 | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | ***IMPORTANT*** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | NOTE NOC WILL BE NULL & VOID 90 DAYS | | | AFTER RECORDING AT THE CLERK OF THE | | | COURTS OFFICE IF WORK HAS NOT STARTED. | | | FL S S 713.13(2). | | | | | | 2) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3) FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | | | | 4) ARCHITECTURAL PAGES DO NOT HAVE A | | | RAISED SEAL. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND | | | BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 6)FL S. S. 553.71(7) " THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN | | | CY CLASSIFICATION AS DEINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL INSPEC | | | TION PLAN PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING AGEN- | | | CY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESH- | | | OLD BUILDING. THE PURPOSE OF THE SRUCTUR | | | AL INSPECTION PLAN IS TO PROVIDE SPECIF- | | | IC INSPECTION PROCEDURES AND SCHEDULES | | | SO THAT THE BUILDING CAN BE ADEQUATELY | | | INSPECTED FOR COMPLIANCE WITH THE | | | PERMITTED DOCUMENTS. | | | | | | 7) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 8) W.P.B. AMENDMENT 105.13.4.4 ALL PLANS | | | FOR THE BUILDING WHICH ARE REQUIRED TO | | | BE SIGNED AND SEALED BY THE ARCHITECT OR | | | ENGINEER OF RECORD CON- TAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR | | | ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 9A) CONTACT LILI URSA FOR ADDRESSING | | | REQUIREMENTS @ (561)822-1239 | | | | | | 9B)PROVIDE A COPY OF THE NEW PLAT, LOT | | | HAS BEEN SUBDIVIDED. | | | | | | 9C) ON ALL (3) PERMIT APPLICATIONS | | | CORRECT THE PROPERTY CONTROL NUMBER TO | | | THE NEW LOT. | | | | | | 9D) PROVIDE A SITE PLAN WITH LOCATION OF | | | | | | THE PROPOSED STRUCTURES WITH DIMENSIONS | | | FOR TABLE 600 ISSUES.A2.01 HAS NO | | | DIMENSIONS! | | | | | | 10A) CORRECT PERMIT APPLICATIONS AS TO | | | DESRIPTION OF WORK FOR THE THREE | | | BUILDINGS, CURRENTLY THERE WILL BE 1350 | | | UNITS ON THIS PROJECT WHEN FINISHED, SEE DESCRIPTION OF | | | PROJECT, EACH APPLICATION | | | FOR BUILDINGS 1, 450 UNITS BUILDING 2 | | | 450 UNITS & BUILDING 3, 450 UNITS | | | TOTALING 1350. . | | | | | | 10B) PLEASE PULL PLANS APART INTO 3 SETS | | | OF PLANS SO ALL PAGES THAT DEAL WITH | | | BUILDING # 1 ARE IN ONE SET ETC. | | | | | | 10C) ADDITIONAL INFORMATION REQUIRED FOR | | | RECORD KEEPING PURPOSES 106.1.2*: | | | 10C)A) FLOOD ZONE | | | 10C)B) FLOOD ELEVATION (IF A ZONE) | | | 10C)C) LOMAR (IF A ZONE) | | | 10C)D) NUMBER OF UNITS | | | 10C)E) NUMBER OF FLOORS | | | 10C)F) NUMBER OF BEDROOMS | | | 10C)G) NUMBER OF ROOMS | | | 10C)H) NUMBER OF BATHROOM | | | 10C)I) SQ FT LIVING SPACE(TOTAL) | | | 10C)J) SQ FT FOOT PRINT | | | 10C)K) SQ FT UNDER ROOF (TOTAL) | | | | | | 10D) THE DESCRIPTION OF BUILDINGS AND | | | PHASING ARE CONFUSING BECAUSE THE | | | TERMINOLOGY, CURRENTLY THE CONTRACTOR | | | HAS PERMIT APPLICATIONS IN FOR BUILDINGS | | | 1,2& 3 NOT 4 NOR 5 AS BUILDINGS ARE | | | DEPICTED ON SHEET A1.02. | | | | | | 10E) A1.04 INDICATES A PHASED PROJECT OF | | | 5 BUILDINGS SEPERATED BY 4 HR WALLS. | | | THEN THERE IS ANOTHER NOTE INDICATING | | | TEMPORARY I HR WALLS WITH 45 MIN RATED | | | DOORS. THIS PLAN IS NOT CLEAR AS WHAT | | | WORK WILL BE COMPLETED WHEN. A MEETING | | | WITH ALL CONCERNED WOULD BE GREATLY | | | APPRECIATED. CONCERNS ON HOW EGRESS WAYS | | | ARE TO BE ADDRESSED. HOW ACTIVE FIRE | | | ALARM, FIRE SPRINKLER WILL BE MAITAINED | | | WITH THE NEW PHASES BEING BUILT. WORK | | | AREA BEING ISSOLATED FROM THE GENERAL | | | PUBLIC.A ACCESSIBLE PATH TO THE RIGHT OF | | | WAY DURING CONSTRUCTION OF ALL PHASES. | | | | | | 10F) THE PHASING PLAN INDICATED ON SHEET | | | A1.04 INDICATES WORK ON BUILDING# 1 THEN | | | JUMPING TO TWO OTHER BUILDINGS THEN BACK | | | TO BUILDING# 1 JUMPING OVER AREAS TO BE | | | PHASED IN LATER VERY IMPARTICAL AS TO | | | HOW LIVE SYSTEMS ELECTRIC WATER AND FIRE SPRINKLERS ARE | | | TO BE BUILT AND | | | MAINTAINED. | | | | | | 10G) THIS REVIEW WILL CONSTITUTE OF | | | BUILDING# 1 OF 515,540 SQ FT. PLANS | | | REFER TO THIS AS BEING BLDG 1,2 & 3. | | | | | | 10H) A1.02 CODE COMPLIANCE FOR APARTMENT BUILDINGS | | | PLANS INDICATE TYPE IV, UNPROTECTED , | | | SPRINKLERED | | | MAXIMUMHEIGHT ALLOWED IS 55' | | | PROPOSED HEIGHT69'-3" | | | PLEASE CORRECT BUILDING TYPE!!!!!! | | | 503.2.2 ALLOWED THE DEDUCTION OF 1 STORY | | | FOR THE PARKING GARAGE IF TYPE I OR TYPE | | | II BUILDING. | | | | | | 10I) THE OTHER ISSUE IS THE ALLOWABLE | | | AREA FOR A TYPE IV , UNPROTECTED, | | | SPREINKLERED BUILDING THE ALLOWABLE | | | AREAIS ONLY 24,000 SQ FT / FL. | | | | | | 10J) EVEN IF THE BUILDING WAS CONSIDERED | | | A TYPE IV , 1 HR PROTECTED, SPRINKLERED | | | BUILDING THE ALLOWABLE AREA INCREASE | | | WILL BE 36,000/ FL BUT THE HEIGHT OF 65' | | | STILL 4'-3" OF THE OVERALL HEIGH OF THE | | | BUILDING, STILL REQUIRING THE 4 FOUR HR | | | FIRE WALLS TO MAKE UP THE TOTAL AREA FOR | | | THIS ONE BUILDING. THE OTHER ISSUE IS | | | THE 4 HR FIRE WALLS DO NOT CONTINUE | | | THROUGH THE GARAGE SEPERATING THEM INTO | | | SEPERATE BUILDINGS. A 3HR FIRE RATED | | | DOOR WOULD BE REQUIRED IN THE GARAGE | | | LEVEL. PLEASE CORRECT. | | | | | | 10K) DISCREPANCY A1.02 CONSTRUCTION TYPE | | | IV UNPROTECTED VS A1.21 FIRE RATING | | | IV I HR RATED. | | | | | | 11) SHEET A1.05 | | | | | | 11A) PLEASE PROVIDE THE LISTING FOR | | | RATED WALLS, U.L. OR OTHER | | | RECOGNIZED LISTING AGENCY. | | | | | | 11B) PLANS INDICATE USE OF RINKER BLOCK, | | | PROVIDE FROM THE MANUCATURER THE | | | EQIVALENT THICKNESS OF BLOCK,709.3.1.1 | | | THE FIRE RESISTANCE RATING OF WALLS AND | | | PARTITIONS CONSTRUCTED OF CONCRETE | | | MASONRY UNITS SHALL BE DETERMINED FROM | | | TABLE 709.3.1.THE RATING SHALL BE | | | BASED ON THE EQUIVALENT THICKNESS OF THE | | | MASONRY AND TYPE OF AGGREGATE USED. | | | | | | 12)SITE PLAN A2.01 | | | | | | 12A) ACCESSIBLE ROUTE: FAIR HOUSING AT | | | LEAST ONE ACCESSIBLE ROUTE SHALL BE | | | PROVIDED WITHIN THE BOUNDARY OF THE SITE | | | FROM PUBLIC TRANSPORTATION STOPS, | | | ACCESSIBLE PARKING SPACES, PASSENGER | | | LOADING ZONES IF PROVIDED, AND PUBLIC | | | STREETS OR SIDEWALKS, TO AN ACCESSIBLE | | | BUILDING ENTRANCE. | | | | | | 12B) SITE PLAN DOES NOT PROVIDE ANY | | | INFORMATION AS TO CURB CUTS, PEDSTRIAN | | | CROSS WALKS, ETC. | | | | | | 13) SHEET A5.40: | | | | | | 13A) ELEVATOR LOBBY DOOR # 5.003 SWINGS | | | THE WRONG WAY AGAINST EGRESS. | | | NO HR RATING! | | | | | | 13B) STAIRWELL# 12,13&14EXIT DOOR NO | | | LISTING, NO RATING! | | | | | | 13C) STAIRWWELL 12 LEAD BACK INTO THE | | | GARAGE NOT THE EXIT DISCHARGE. | | | | | | 13D) TRASH REFUSE ROOM# 5NO RATING | | | | | | 13E) FIRE PUMP ROOM NO RATING OF DOOR | | | | | | 13F) PARKING GARAGE TO BE CONSIDERED AN | | | ENCLOSED PARKING GARAGE PROVIDE | | | COMPLIANCE WITH 6 AIRCHANGES PER | | | HR.411.4.2. | | | | | | 13G) MAILBOXES SEE DETAIL A5.56 DETAIL | | | # 7, PROVIDE DIMENSIONS (ELE) TO COMPLY | | | WITH SIDE REACH RANGES. | | | | | | 13H) PLANS ARE NOT CLEAR IF STAIRWELL | | | 12 & 4 ARE IN PHASE "D" OR PHASE "E". IF | | | LOCATED IN 2ND PHASE DEAD END | | | CORRIDORS EXIST. | | | | | | 13I) GARAGE 4 HR FIRE WALL, PROVIDE 3 HR | | | FIRE RATED DOOR BETWEEN BUILDINGS, | | | INDICATE HOW DOOR WILL ACTIVATE WITH THE | | | SMOKE/ FIRE ALARM? | | | 705.1.3.1 WALL OPENINGS REQUIRED TO BE | | | PROTECTED SHALL BE PROTECTED BY APPROVED | | | LISTED AND LABELED FIRE DOORS, WINDOWS | | | AND SHUTTERS AND THEIR ACCOMPANYING | | | HARDWARE, INCLUDING ALL FRAMES, CLOSING | | | DEVICES, ANCHORAGE AND SILLS, IN | | | ACCORDANCE WITH THE REQUIREMENTS OF NFPA | | | 80, EXCEPT AS OTHERWISE SPECIFIED IN | | | THIS CODE. | | | | | | | | | | | | | | | | | | 14)BUILDING# 5 SHOWS PHASING AND IT | | | APPEARS TO BE A SINGLE 4HR FIRE WALL | | | SEPERATING THIS BUILDING INTO 2 SEPERATE BUILDINGS. THE | | | STAIR TOWER WILL HAVE | | | TO BE BUILTWITH A 4HR WALL, ROOF | | | STRUCTURE INDEPENDENT OF THE OTHER | | | BUILDINGS AND DIRECT ACCESS FROM EACH OF | | | THE BUILDINGS EXIT ACCESS CORRIDORS,PLUS | | | THE REQUIRED 3 HR OPENING PROTECTIVES. | | | YOUR BUILDINGS DESIGN WAS BROUGHT TO THE | | | BUILDING OFFICIAL FOR HIS INTERPRETATION | | | | | | PLANS INDICATE TYPE IV UNPROTECTED, | | | FIRE SPRINKLERED TABLE 600 ALLOWS 24,000 | | | SQ FT PER FLOOR PLANS INDICATE 28,486 | | | PER FLOOR. AREA INCREASES IF TAKEN | | | APPEARS TO MEET THE CODE FOR AREA, THERE | | | SEEMS TO BE A PROBLEM WITH HEIGH | | | PROPOSED 69' ALLOWED 55'. | | | | | | | | | DEF:WALL, PARTY. A FIRE WALL ON AN | | | INTERIOR LOT LINE, USED OR ADAPTED FOR | | | JOINT SERVICE BETWEEN TWO BUILDINGS. | | | | | | SELF-CLOSING. AS APPLIED TO A FIRE DOOR | | | OR OTHER OPENING, MEANS NORMALLY CLOSED | | | AND EQUIPPED WITH AN APPROVED DEVICE | | | WHICH WILL INSURE CLOSING AFTER HAVING | | | BEEN OPENED FOR USE. | | | | | | 705.1.3.1 WALL OPENINGS REQUIRED TO BE | | | PROTECTED SHALL BE PROTECTED BY APPROVED | | | LISTED AND LABELED FIRE DOORS, WINDOWS | | | AND SHUTTERS AND THEIR ACCOMPANYING | | | HARDWARE, INCLUDING ALL FRAMES, CLOSING | | | DEVICES, ANCHORAGE AND SILLS, IN | | | ACCORDANCE WITH THE REQUIREMENTS OF NFPA | | | 80, EXCEPT AS OTHERWISE SPECIFIED IN | | | THIS CODE. | | | | | | 705.1.5 OPENING PROTECTION IN STAIRWAY | | | ENCLOSURES. OPENING PROTECTIVESIN | | | STAIRWAY SHAFTS ARE LIMITED TO | | | SELF-CLOSING OR SMOKE ACTUATED, | | | AUTOMATIC-CLOSING FIRE DOOR | | | ASSEMBLIES.IF SMOKE-ACTUATED CLOSURES | | | CLOSE ONE DOOR, ALL DOORS SERVING THAT | | | STAIRWAY SHALL CLOSE. | | | | | | THE OTHER ISSUE IS A UNITY OF TITLE | | | WOULD BE REQUIRED EVEN FOR A SINGLE LOT | | | AS TO NOT BE ABLE TO SELL OFF A PORTION | | | OR BUILDING CREATING A CODE VIOLATION. | | | | | | 15) SHEET A5.41: | | | | | | 15A) TRASH ROOM DETAIL 1&2 OF A8.20 THE | | | DETAIL IS MISSING THE ENCLOSURE TO THE | | | BOTTOM OF THE CHUTE ENCLOSURE.705.2.4.2 | | | ALL OPENINGS INTO THE SHAFT ENCLOSURE, | | | INCLUDING THOSE FROM ACCESS ROOMS AND | | | TERMINATION ROOMS, SHALL BE PROTECTED IN ACCORDANCE | | | WITH TABLE 705.1.2.SUCH | | | OPENING PROTECTIVES SHALL BE | | | SELF-CLOSING OR AUTOMATIC-CLOSING UPON | | | DETECTION OF SMOKE, EXCEPT THAT THE | | | OPENING PROTECTIVE BETWEEN THE SHAFT AND | | | THE TERMINATION ROOM MAY BE CLOSED BY A HEAT-ACTIVATED | | | DEVICE. | | | | | | 15B) THE TERMINATION ROOM DOOR NO | | | INFORMATION ON RATING? | | | | | | 16) VARIOUS SHEETS ON BUILD# 5 | | | INDICATE A DETAIL SECTION# 23 SHEET | | | A7.10. | | | | | | 16A) THIS SECTION INDICATES METAL | | | TRUSSES TO BE USED BUT NO INFORMATION | | | AS TO THE ROOF DECKING MATERIAL TO BE | | | USED? TYPE IV UNPROTECTED- NC | | | TYPE IV 1HR- IHR PROTECTED | | | | | | 16B) PROVIDE A DETAIL INDICATING ACCESS | | | TO ATTIC AREA. | | | | | | 16C) THIS SAME SECTION INDICATES USE OF | | | FOAM TRIM ON THE EXTERIOR OF THE | | | BUILDING ABOVE 40'.1404.1.1 | | | ARCHITECTURAL TRIM ON BUILDINGS OF TYPE | | | I, II AND IV CONSTRUCTION NOT MORE THAN | | | THREE STORIES OR 40 FT (12.2 M) HIGH MAY | | | BE OFTYPE VI CONSTRUCTION, AND MAY BE | | | OF TYPE VI CONSTRUCTION ON ALL BUILDINGS | | | OF TYPE III, V AND VI CONSTRUCTION. | | | TRIM SHALL BE SECURED TO THE WALL WITH | | | METAL OR OTHER APPROVED BRACKETS OR | | | FASTENERS.WHEN ARCHITECTURAL TRIM IS | | | LOCATED ALONG THE TOP OF EXTERIOR WALLS, | | | IT SHALL BE COMPLETELY BACKED BY THE | | | EXTERIOR WALL AND SHALL NOT EXTEND OVER | | | THE TOP OF EXTERIOR WALLS. | | | | | | | | | 17) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 18) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) OPARATABLE WINDOWS | | | B) FIXED WINDOWS | | | C) MULLION | | | D) EXTERIOR DOORS SOLID | | | E) EXTERIOR DOORS GLAZED | | | F) EXTERIOR DOORS LOUVERED | | | G) STORM SHUTTERS | | | H) EXTERIOR RAILINGS | | | I) LOUVERS | | | J) TRUSS ANCHORS | | | K) ROOFING ASSEMBLIES | | | L) EFIS SYSTEMS | | | | | | 19) AN INTERPRETATION FROM THE BUILDING | | | OFFICIAL ON STORM SHUTTERS THAT ARE USED | | | ON LARGE PROJECTS: | | | QUESTION# 13) RECOGNIZING SUCH CONCERNS | | | AS ABSENTEE OWNERS, OR CASES WHERE | | | LONGER TIME AND EFFORT IS NECESSARY TO | | | SECURE SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDINGS, WHAT MEASURES ARE BEING | | | RECOMMENDED OR IMPLEMENTED TO ENSURE | | | THAT COMPLETE INSTALLATION OR SECURING | | | IS DONE SUFFICIENTLY IN ADVANCE OF THE | | | HURRICANE EVENT? | | | | | | IN MATTERS FLORIDA BUILDING CODE, 2004 | | | EDITION, PROVIDES THE ABILITY FOR THE | | | BUILDING OFFICIAL TO IMPLEMENT | | | REQUIREMENTS FOR ENSURING STABILITY, | | | STRENGTH, AND PROPER OPERATION OF | | | EXISTING BUILDINGS. | | | | | | IN ORDER TO ASSURE THE SECURING OF | | | SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDING, OR MULTIPLE BUILDINGS ON THE | | | SAME PROPERTY, PRE-STORM PREPARATION | | | PLANS MUST BE SUBMITTED BY THE PROPERTY | | | OWNERS OR MANAGING AGENTS FOR REVIEW BY | | | THE CONSTRUCTION SERVICES DEPARTMENT. | | | ANY SUCH PLAN SHALL INCLUDE, AT A | | | MINIMUM, ON-SITE LOCATION OF SHUTTERS, | | | PARTY RESPONSIBLE FOR SECURING THE | | | SHUTTERS (SAID PARTIES MUST BE LOCATED | | | WITHIN PALM BEACH COUNTY), TOTAL NUMBER | | | OF OPENINGS TO BE PROTECTED AND TOTAL | | | TIME REQUIRED TO SECURE ALL OPENINGS. | | | PROTECTION OF OPENINGS SHALL BE | | | ACCOMPLISHED WITHIN TWELVE (12) HOURS OR | | | LESS OF THE OFFICIAL NOTIFICATION BY THE | | | NATIONAL WEATHER SERVICE OF A HURRICANE | | | WATCH. | | | | | | PROVISIONS IN THE BUILDING CODES (AND | | | THIS STANDARD) ARE NOT INTENDED TO | | | PROHIBIT THE USE OF ALTERNATIVE | | | MATERIALS AND METHODS, AND ALLOW THE | | | BUILDING OFFICIAL TO REVIEW AND APPROVE | | | ANY ALTERNATE DEEMED EQUIVALENT IN | | | QUALITY, STRENGTH, EFFECTIVENESS, FIRE | | | RESISTANCE, DURABILITY AND SAFETY | | | PRESCRIBED BY CODE. BASED UPON THIS CODE PROVISION, | | | ACCEPTANCE OF ALTERNATE | | | MATERIALS AND METHODS MAY BE APPROVED ON | | | A CASE-BY-CASE BASIS AND SHALL REQUIRE | | | SUFFICIENT EVIDENCE OR PROOF TO | | | SUBSTANTIATE ANY CLAIM MADE REGARDING | | | THE ALTERNATE. | | | | | | QUESTION# 14) ARE REMOVABLE STORM PANELS APPROPRIATE | | | FOR USE ON VERY LARGE, MID | | | OR HIGH-RISE STRUCTURES? | | | | | | NO, EXCEPT ON THE GROUND FLOOR. ON | | | COMMERCIAL AND MULTI-UNIT RESIDENTIAL | | | STRUCTURES, ABOVE THE FIRST LEVEL, | | | IMPACT RESISTANT GLAZING OR PERMANENTLY | | | AFFIXED PROTECTIVE DEVICES SHALL BE | | | INSTALLED. PERMANENTLY AFFIXED | | | PROTECTIVE DEVICES SHALL REQUIRE THE | | | WRITTEN APPROVAL OF THE BUILDING | | | OFFICIAL. | | | | | | 20) PROVIDE STORM PANEL INFORMATION WITH INSTALLATION | | | SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | FBC 1606.1.4. | | | | | | 21) FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 22) 3003.6.1 VENTS. HOISTWAYS OF ELEVA- | | | TORS SERVING MORE THAN 3 FLOORS SHALL BE | | | PROVIDED WITH MEANS OF VENTING SMOKE AND | | | HOT GASES TO THE OUTER AIR IN CASE OF | | | FIRE. | | | | | | 23)3003.6.2 VENTS SHALL BE LOCATED BELOW | | | THE FLOOR OR FLOORS AT THE TOP OF THE | | | HOISTWAY, AND SHALL BE EITHER DIR- ECTLY | | | TO THE OUTER AIR OR THROUGH NON- | | | COMBUSTIBLE DUCTS TO THE OUTER AIR. | | | | | | 24) 3003.6.3 THE AREA OF THE VENTS SHALL | | | BE NOT LESS THAN 3 SQ FT FOR EACH | | | ELEVATOR CAR, WHICHEVER IS GREATER. | | | | | | 25)SHEET S4.00 INDICATES THE ROOF ZONES | | | FOR A SIMPLE RECTANGLE. PROVIDE A | | | DETAILED ZONE MAP AS IT RELATES TO THIS | | | BUILDING INCLUDING PENTHOUSES WITH THE | | | APPROPRIATE PRESSURES. | | | | | | 26) A9.03 WINDOW BUCK DETAIL CORRECT: | | | 1707.4.4.2 TAPERED BUCKS: | | | SHALL EXTEND BEYOND THE INTERIOR FACE | | | OF THE WINDOW OR DOOR FRAME SUCH THAT | | | FULL SUPPORT OF THE FRAME IS SUPPORTED. | | | | | | 27) S3.51-S3.54 | | | 1511.7 ROOF MOUNTED MECHANICAL UNITS | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | | | | 28) 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 29) ELECTRICAL SHEETS MISSING SMOKE | | | ALARMS IN BEDROOMS.905.1.1A FIRE ALARM | | | SYSTEM IN ACCORDANCE WITH NFPA 72SHALL | | | BE INSTALLED. | | | | | | ADDITIONAL COMMENTS MAY APPEAR ON THE | | | NEXT REVIEW NOT COVERED FROM THE FIRST | | | REVIEW DUE TO THE COMMENT RESPONCEOR | | | ADDITIONAL INFORMATION NOT PROVIDED | | | UNDER THE FIRST REVIEW. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-20 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-16 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2007-09-20 08:19:00 | | | | ** DENIED 3RD REVIEW** | | | | | | ** PLEASE SEE THERE ARE SOME ITEMS FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING. PLEASE ALSO SEE | | | THERE ARE SOME NEW COMMENTS BASED ON REVISED | | | PLANS/PLANS AND DOCUMENTS NOW SUBMITTED. | | | ** SOME ITEMS COULD HAVE BEEN REDLINED/PROVISO, HOWEVER | | | MANY OF THESE ARE IN NEED OF ADDRESSING AT THIS TIME. | | | | | | 1) NOTE:PLEASE SEE THE PLANS DO NOT INDICATE FIXTURE | | | DESIGNATIONS FOR ALL LIGHTING. PLEASE SEE THERE ARE | | | SEVERAL AREAS INCLUDING FIRST FLOOR AND OTHER FLOORS | | | WHERE FIXTURES ARE STILL MISSING DESIGNATIONS. PLEASE | | | SEE THE FIXTURE LEGEND COULD NOT BE COORDINATED WITH | | | THESE AT THIS TIME. | | | PLEASE SEE COMMON AREAS WHICH THE LEGEND ON ELECTRICAL | | | PLANS COULD NOT BE FOUND. | | | PLEASE SEE THE INFORMATION ON THE INPUT DATA REPORT FOR | | | EXTERIOR LIGHTING ALSO NEEDS TO CORRELATE WITH PLANS. | | | THE LIGHTING, TYPES, NUMBER OF FIXTURES, ETC IS NOT | | | STATED ON THE IDR AS ON PLANS. | | | PLEASE SEE THE ENERGY CALCULATIONS AS SUBMITTED AS THE | | | INPUT DATA REPORT DOES NOT CORRELATE WITH ALL | | | ELECTRICAL LIGHTING FOR INTERIOR LIGHTING WHICH IS ON | | | PLANS. PLEASE SEE MISSING A SUBSTANTIAL AMOUNT OF | | | LIGHTING ON THE INPUT DATA REPORT. | | | 13-415.0, 415.1.ABCD, 415.1.A, 415.2 | | | | | | 2) NOTE: PLEASE SEE ONLY ONE COPY OF THE ENERGY | | | CALCULATIONS (1.22 VERSION) SUBMITTED ACTUALLY CONTAINS | | | AN ORIGINAL SIGNATURE AND DATE. PLEASE SEE THAT TWO | | | SETS CONTAIN A RAISED SEAL OVER A PHOTO-COPIED | | | SIGNATURE AND THE THIRD DOES NOT CONTAIN A RAISED | | | SEALED OR ORIGINAL SIGNATURE. | | | **PLEASE KNOW THIS COMMENT HAS BEEN MADE TO THIS DESIGN | | | PROFESSIONAL ON SEVERAL PROJECTS SUBMITTED TO THIS | | | JURISDICTION. THIS COMMENT WILL ALSO BE UNDER BUILDINGS | | | 1 AND 3. | | | PLEASE KNOW THIS OFFICE IS RETAINING ALL COPIES | | | SUBMITTED FOR POSSIBLE SUBMISSION TO THE FLORIDA BOARD | | | OF ENGINEERS. | | | THIS IS A FLORIDA STATUTE AND IS ALSO STATED IN THE | | | FLORIDA ADMINISTRATIVE CODE.FS 471.025, FAC | | | 61G15-23.002, FBC 103.1. | | | ** WHEN PLANS WERE RE-SUBMITTED THIS REVIEWER NOTICED | | | THE INCORRECT VERSION ON THE CALCULATIONS SUBMITTED AND | | | NEW CALCULATIONS WITH THE CORRECT VERSION WAS SENT VIA | | | FED-EX. PLEASE SEE THAT THE ONES DONE UNDER THE 2004 | | | FBC WERE ALSO NOT SIGNED, DATED AND SEALED CORRECTLY | | | AND AS REQUIRED BY THE FLORIDA STATUTES. THIS SHOWS | | | SAME NON-COMPLIANCE ON MULTIPLE SETS OF DOCUMENTS. | | | ** PLEASE BE SURE TO GO OVER ALL AND CORRECT. | | | | | | 3) NOTE: PLEASE SEE INFORMATION FOR SITE LIGHTING POLES | | | DO NOT CONTAIN THE MINIMUM WIND LOAD INFORMATION. | | | PLEASE KNOW IF THIS INFORMATION IS NOT COMPLETE UNDER | | | BASE PLANS, THESE WILL BE REQUIRED TO BE UNDER SEPARATE | | | PERMITS, PLANS AND FEES. | | | PLEASE KNOW HOWEVER THE LIGHTING INFORMATION AS NOTED | | | ABOVE IN NOTE #1 FOR THE ENERGY CALCULATIONS WILL STILL | | | NEED TO BE CORRECTED. | | | PLEASE IDENTIFY THE CIRCUITS AS SHOWN ON PLANS TO WHICH | | | BUILDING HOUSE PANEL THEY TERMINATE. PLEASE SEE THIS IS | | | DONE FOR THE SITE LIGHTING CIRCUITS FOR BUILDING #2 BUT | | | NOT THE OTHERS. | | | | | | 4) NOTE: PLEASE SEE THE SYMBOL LEGEND STILL INDICATES | | | *SMOKE DETECTORS*. THIS COULD BE REDLINED IF AND WHEN | | | ALL OTHER COMMENTS AS ADDRESSED. PLEASE KNOW IF THERE | | | ARE ANY COMMENTS HOWEVER WHICH MAY AFFECT THE SAME | | | SHEET(S), PLEASE CORRECT AT THIS TIME. E16.01 THIS | | | COULD BE REDLINED ON THIS SHEET IF NOT OTHER CHANGES IS | | | MADE. | | | | | | 5) NOTE: PLEASE BE SURE TO CORRELATE ALL LAYOUTS FOR | | | UNITS AS THE ELECTRICAL PLANS SEEM TO HAVE DIFFERENT | | | LAYOUT(S) FOR SOME UNITS. PLEASE SEE C-3 FOR EXAMPLE ON | | | 16.03, 16.04. | | | PLEASE CORRELATE THE TWO AS THESE LAYOUTS DO NOT MATCH | | | AT THIS TIME. | | | PLEASE SEE ANY CHANGES IN LIGHTING ETC. PLEASE ALSO BE | | | SURE TO COORDINATE WITH THE A-SHEETS. | | | FBC 104.1.2 (2001) ADMIN SECTION FOR ADDITIONAL | | | INFORMATION AND COORDINATION OF PLANS. | | | | | | 6) NOTE: PLEASE SEE DISHWASHER AND DISPOSAL WHICH IS | | | BEING SHOWN WITH A J-BOX. ARE THESE ITEMS GOING TO BE | | | HARDWIRED? | | | PLEASE SEE 422.30, 422.31 FOR REQUIRED DISCONNECTING | | | MEANS. | | | ARE THESE NOT CORD AND PLUG TYPE APPLIANCES WHICH WOULD | | | PLUG IN? | | | | | | 7) NOTE: PLEASE SEE BUILDING REVIEW COMMENTS AND PLEASE | | | KNOW THERE ARE SEVERAL A-SHEETS ON THE REVIEWED SET | | | WHICH WERE NOT SEALED WITH THE RAISED EMBOSSED SEAL AS | | | REQUIRED UNDER FS 481.221, FAC 61G1-16.002 | | | | | | 8) NOTE: PLEASE SEE THE LIGHT FIXTURE OUTSIDE FIRE PUMP | | | ROOM WILL BE REQUIRED TO BE BATTERY BACK UP. THIS IS | | | SHOWN AS A *J* FIXTURE. AS NO FIXTURE LEGEND WAS | | | SUBMITTED THIS CAN NOT BE VERIFIED AT THIS TIME. | | | PLEASE ALSO SEE ARE OUT SIDE ELEVATOR EQUIPMENT AREA | | | AND MAIN ELECTRICAL ROOM WILL ALSO REQUIRE AN EMERGENCY | | | BATTERY BACK UP LIGHTING FIXTURE OF SOME KIND. | | | NEC 700.12E, 700.16, LS-101 7.8, 7.9 | | | | | | 9) NOTE: PLEASE SEE RISER NOTE #10 WHICH MENTIONS | | | CONDUCTORS BEING INSTALLED BY POWER COMPANY HOWEVER | | | PLEASE KNOW THE POWER COMPANY (FPL) FLORIDA POWER AND | | | LIGHT SHOULD BE CONSULTED. | | | IT IS KNOWN TO THIS OFFICE THAT THESE CONDUCTORS AFTER | | | THE METERING DEVICES ARE NOT INSTALLED BY THE POWER | | | COMPANY AND IN FACT THERE ARE SEVERAL TIMES THE SERVICE | | | ENTRANCE CONDUCTORS FROM THE TRANSFORMERS TO THE | | | SERVICE METERS AND MAINS ARE ACTUALLY OWNER SUPPLIED. | | | THIS WOULD PLACE ALL CONDUITS AND CONDUCTORS UNDER THE | | | NEC FOR CODE COMPLIANCE. | | | PLEASE ADJUST RISER FOR CONDUCTORS ETC. | | | 240.4, 310.16 | | | FBC 106.3.5.1.2 | | | | | | 10) NOTE: PLEASE CLARIFY THE FIRE PUMP AND INFORMATION | | | AS REQUESTED ON THE PREVIOUS REVIEWS. | | | PLEASE SEE NO INFORMATION WAS SUBMITTED WITH RESPECT TO | | | THE MINIMUM FUEL REQUIREMENTS AND SIZE OF TANK. PLEASE | | | SEE NO TIMES AT 100% RUNNING IS SHOWN. | | | PLEASE SEE NFPA-20 9.6.2.2 AND SEE COMMENTS FROM FIRE | | | MARSHAL. | | | PLEASE SEE THE FUEL NOTE WHICH IS ON SHEET FP13.09 #3, | | | DOES NOT CONTAIN THE TEXT FOR CODE. | | | PLEASE SEE THE MINIMUM ON THE BASE BUILDING IS REQUIRED | | | AT THIS TIME. | | | PLEASE SEE THE PREVIOUS NOTES WHICH REQUESTED THIS SAME | | | INFORMATION. | | | PLEASE SEE THE FP SHEETS INDICATE A DIESEL FIRE PUMP, | | | YET THE SUBMITTALS WHICH WERE SUBMITTED WITH PLANS | | | INDICATE AN ELECTRICAL FIRE PUMP. | | | PLEASE SUBMIT THE ACTUAL DOCUMENTATION AND CORRELATE | | | WITH PLANS. | | | 110.3, 90.7, NFPA-70 695, NFPA-20 2003 | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | | | | *** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS | | | OR COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. | | | IF THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY | | | WAY, NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, | | | PLEASE DO NOT HESITATE IN CONTACTING THIS OFFICE AND | | | THIS REVIEWER. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-09-18 16:30:27 | 2007-09-18 16:30:27 | | | | | | REVIEW COMMENCED ON BLDG #3 | | 2007-09-16 13:06:51 | 2007-09-16 13:06:51 | | | | | | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-12-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-31 |
Time |
19:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-29 |
Time |
18:16 |
Sent To |
|
|
| Notes |
| 2006-12-31 19:44:43 | **** UNSAT2ND REVIEW ******** | | | | | | COURTNEY LAKES BUILDING #3 | | | N. CONGRESS. | | | | | | ** PLEASE SEE MANY OF THE SAME COMMENTS FROM THE | | | PREVIOUS REVIEW STILL NEED TO BE ADDRESSED. | | | | | | ** PLEASE SEE AS THREE SEPARATE BUILDING PERMITS AND | | | PLANS ARE NOW SEPARATED FOR EACH, PLEASE ALSO SEE NEW | | | COMMENTS BASED ONE THE PLANS NOW SUBMITTED INTO EACH | | | SET. | | | | | | ** PLEASE ALSO SEE THERE ARE SOME NEW NOTES BASED ON | | | PLANS SUBMITTED. | | | | | | ** PLEASE SEE BELOW ARE SOME OF THE NOTES FROM THE | | | PREVIOUS REVIEW ARE BEING NOTED IF ADDRESSED OR NOT BY | | | A "NO, OK, NO/OK, N/A OR SEE NEW ". | | | 1) NO WILL HAVE FURTHER EXPLANATION IN AN ATTEMPT TO | | | BETTER EXPLAIN COMMENT MADE. | | | 2) OK, WILL HAVE PREVIOUS NOTE REMOVED. | | | 3) NO/OK, MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL. THIS WILL ALSO BE FOLLOWED | | | BY FURTHER EXPLANATION OF PREVIOUS NOTE. | | | 4) N/A, THIS MEANS THE COMMENT NO LONGER APPLIES TO | | | THIS BUILDING AND PREVIOUS NOTE IS REMOVED. | | | | | | ** PLEASE SEE ALL NEW NOTES WILL BE NOTED AT THE END OF | | | PREVIOUS REVIEW COMMENTS AND WILL BE INDICATED WITH | | | **** NEW NOTES**. | | | | | | | | | 1) NOTE: OK. SEE NOTES. | | | | | | 2) NOTE: OK | | | | | | 3) NOTE:NO, PLEASE SEE RESPONSE MENTIONS PLANS | | | DESIGNED UNDER THE CODES AS NOTED, HOWEVER ALL CODES | | | RELEVANT TO THE DESIGN IN WHICH THE BUILDING IS | | | PERMITTED UNDER SHALL BE STATED ON PLANS. PLEASE SEE | | | THIS IS REQUIRED OF ARCHITECTURAL SHEETS AS WELL AS | | | ELECTRICAL AND FIRE. PLEASE SEE ANY OTHER NOTES WITH | | | RESPECT TO THIS FROM OTHER TRADES. | | | THE FOLLOWING SHALL BE STATED. 2002 NEC/NFPA-70, 2002 | | | NFPA-72, 2003 NFPA-20 AND 2003 NFPA-101. (THE CORRECT | | | NFPA-101 IS NOTED ) | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE BE SURE TO CORRECT THE CURRENT NEC/ NFPA-70 IN | | | EFFECT. | | | PLEASE KNOW, AS OF JULY 1ST, 2003 THE STATE OF FLORIDA | | | ADOPTED THE 2002 | | | NFPA-70 (NEC). PLANS REFERENCE 1999. PLEASE SEE SOME | | | ELECTRICAL COMMENTS WHICH WILL AFFECT THIS. | | | PLEASE SEE NEXT COMMENT WITH RESPECT TO PERMITS APPLIED | | | FOR UNDER THE 2001 FBC BEFORE OCT 1ST, 2005 AND PERMITS | | | ON OCT 1ST, 2005. | | | | | | 4) NOTE: N/A, SEE NEW NOTES FOR EACH BUILDING. | | | | | | | | | 5) NOTE: N/A, SEE NEW NOTES UNDER EACH BUILDING. | | | | | | 6) NOTE:NO, PLEASE SEE THERE ARE SEVERAL AREAS WHICH | | | CIRCUITING IS NOT COMPLETE INCLUDING UNITS FOR SMOKE | | | DEVICES AND MANY AREAS OF HOUSE/COMMON AREAS/ SITE ETC. | | | PLEASE SEE MANY NEW COMMENTS BASED ON PLANS SUBMITTED. | | | PLEASE SHOW ALL AND CORRELATE WITH THE SUBMITTED PANEL | | | SCHEDULES. SEE NEW NOTES. | | | FBC ADMIN SECTION 104.1.2 | | | | | | PLEASE COMPLETE ALL CIRCUITING ON PLANS IN ORDER TO | | | REVIEW CODE COMPLIANCE FOR AREAS OF UNITS AND COMMON | | | AREAS. | | | | | | 7) NOTE: NO, SAME COMMENT. THIS IS NOT EXPLAINED ANY | | | FURTHER. PLEASE HOWEVER ALSO SEE NEW COMMENTS BASED ON | | | PLANS SUBMITTED. | | | ** PLEASE KNOW THERE ARE AREAS OF PLANS WITH | | | DESIGNATIONS, ITEMS FOR CODE COMPLIANCE FOR CIRCUITING | | | TO THOSE AREAS CAN NOT BE VERIFIED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE ROOM AND AREA DESIGNATIONS ON PLANS, | | | INCLUSIVE OF ALL UNITS AND COMMON AREAS. | | | REVIEW FOR SOME CODE COMPLIANCE ITEMS CAN NOT BE DONE | | | AT THIS TIME. | | | | | | 8) NOTE:NO, PLEASE SEE RESPONSE LETTER MENTIONS TO | | | SEE SHEET AP E16.00A, YET PLEASE KNOW COMPLETED | | | PHOTO-METRICS SHALL BE SUBMITTED IN EACH SUBMITTED | | | PLANS FOR EACH BUILDING AS EACH BUILDING IS ITS OWN | | | LEGAL RECORD. | | | PLEASE ALSO SEE PREVIOUS NOTES, PLEASE SEE ONLY PARTIAL | | | PHOTO-METRICS WERE SUBMITTED. PLEASE SEE NOTE WHICH | | | REQUIRES ALL UNDER NORMAL AND EMERGENCY AND FOR ALL | | | EGRESS AREAS. PLEASE SEE ONLY SOME ARE BEING SHOWN IN | | | THE PLANS UNDER BUILDING ONE. PLEASE KNOW THESE CAN BE | | | TYPICAL, HOWEVER THEY SHALL ALSO BE SPECIFIC TO EACH | | | AREA IF THE LAYOUT OF THESE AREAS CHANGES WHICH THEY | | | DO. NOT ALL AREAS ARE THE LIKE. | | | PLEASE SEE NEW NOTES ALSO FOR EGRESS FROM UNITS AND | | | PLEASE SEE NEW NOTES PERTAINING TO PARKING LOT, AND | | | SITE LIGHTING. | | | PLEASE KNOW AS THE SWIMMING POOL IS NOT UNDER THIS | | | PERMIT FOR THE BUILDING, STAMPED PLANS FROM PALM BEACH | | | COUNTY HEALTH DEPT IS NOT REQUIRED AT THIS TIME UNDER | | | THIS PERMIT. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE COMPLETE PHOTO-METRICS FOR ALL COMMON | | | AREAS, GARAGE AREA, COMMON AREA CORRIDORS, STAIR TOWERS | | | ETC. | | | PLEASE SEE 2003 NFPA-101 7.8.1.3 AND 7.9.2.2 WHICH | | | REQUIRE A MIN OF 10FT CANDLES FOR STAIR TOWERS UNDER | | | NORMAL OPERATION AS WALK SURFACE AND A MIN OF 1FT | | | CANDLE AT WALK SURFACE UNDER EMERGENCY CONDITIONS. | | | PLEASE ALSO SEE OTHER WALK AREAS, GARAGE, CORRIDORS ETC | | | AND THE MIN OF 1FT CANDLE. | | | **PLEASE SEE PALM BEACH COUNTY SECURITY CODE ORDINANCE | | | WITH RESPECT TO MIN DESIGN OF PARKING LOT LIGHTING | | | LEVELS UNDER NORMAL CONDITIONS. (ONLY NOTED FOR DESIGN) | | | NOT REQUIRED. PLEASE SEE ANY REQUIREMENTS FROM INS | | | CARRIER WHICH REQUIRES A MIN LEVEL OF LIGHTING. | | | ** PLEASE SEE PHOTO-METRICS OR SITE PLAN WAS NOT | | | SUBMITTED FOR PROPOSED POOL AREA. THE POOL STRUCTURE IS | | | REQUIRED TO BE UNDER A SEPARATE PERMIT. PLEASE KNOW, | | | THE PHOTO-METRICS FOR POOL AREA WILL BE REQUIRED AND | | | WILL ALSO BE REQUIRED TO BE REVIEWED AND STAMPED BY THE | | | PALM BEACH COUNTY HEALTH DEPT FOR ANY PROPOSED | | | NIGHT-TIME SWIMMING. | | | | | | 7) NOTE: NO, PLEASE SEE EACH SET OF PLANS SHALL CONTAIN | | | A SITE LIGHTING PLAN SHOWING ALL CIRCUITING AND | | | CORRELATE WITH EACH OF THE HOUSE PANELS FOR EACH | | | BUILDING IN WHICH THEY ARE BEING CIRCUITED TO. PLEASE | | | SEE ALL SITE LIGHTING AS SHOWN IN THE SET OF PLANS FOR | | | BUILDING ONE. PLEASE SEE THE CIRCUITING AS SHOWN DOES | | | NOT CORRELATE WITH HOUSE PANEL FOR BUILDING THREE IN | | | ANY WAY. PLEASE SEE HOUSE PANEL FOR THESE CIRCUITS ARE | | | IN FACT BLANK AND SHOWS THE WORDING OF "SPACE". PLEASE | | | KNOW AT THIS TIME THERE ARE MANY ITEMS PERTAINING TO | | | SITE LIGHTING WHICH CAN NOT BE VERIFIED FOR VOLTAGE | | | DROP, CIRCUITS, OVER CURRENT PROTECTION, CONDUCTOR | | | SIZES ETC. | | | PLEASE SEE NO INFORMATION WAS SUBMITTED OR SHOWN FOR | | | WIND LOADS ON POLES. | | | 240.4, 310.16, 408.4, FBC 104.2.1,104.21.2 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE NO "ELECTRICAL SITE-PLAN" WAS SUBMITTED FOR | | | ANY SITE LIGHTING, LANDSCAPE LIGHTING ETC. | | | PLEASE KNOW, IF NOT SUBMITTED UNDER THIS PERMIT AND | | | VALUES ADJUSTED ACCORDINGLY, SEPARATE PERMIT , PLANS | | | AND FEES WILL BE REQUIRED FOR ALL SITE LIGHTING, | | | LANDSCAPE LIGHTING WORK. | | | ** ALSO NOTE: IN THAT COMPLETE WIND LOADING | | | CALCULATIONS FOR LT POLES INCLUSIVE OF THE ATTACHMENT | | | OF LT FIXTURES WILL BE REQUIRED TO BE SUBMITTED WITH | | | PLANS AND PERMIT APPLICATION FOR REVIEW. | | | | | | 8) NOTE: NO, PLEASE SEE ONCE AGAIN NOT ALL ROOMS ARE | | | DONE AS REQUIRED. PLEASE SEE MAIN ELECTRICAL ROOM FOR | | | THIS BUILDING ALONE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INCLUDE AN EMERGENCY BATTERY BACK UP LT OF SOME | | | SORT IN ALL ELECTRICAL ROOMS, FIRE PUMP ROOM, AND | | | ELEVATOR MACHINE RMS. SOME ARE SHOWN, BUT NOT ALL. | | | 7.8,7.9, 700.16 ETC | | | | | | 9) NOTE:NO, PLEASE SEE NOT ONLY ARE MANY CIRCUITS NOT | | | SHOWN ON PLANS NO CHANGES FOR THE REQUIRED DEDICATED | | | CIRCUITS HAVE BEEN MADE. PLEASE SEE PLANS AND CORRELATE | | | WITH THE HOUSE PANEL FOR THIS BUILDING. | | | PLEASE SEE 620.22,23,24 AND 620.51 ETC | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 620.23, AND 620.24 FOR REQUIRED DEDICATED | | | BRANCH CIRCUITS FOR ELEVATOR PITS, AND ELEVATOR MACHINE | | | RMS/EQUIPMENT AREAS. | | | PLEASE ADJUST HOUSE PANELS AS NEEDED. | | | | | | 10) NOTE: NO, PLEASE SEE NO INFORMATION WAS LOCATED ON | | | RISER SHEETS. PLEASE SEE NO INFORMATION WAS SHOWN ON FP | | | FOR THE FIRE PUMP, SIZE, FUEL CONSUMPTION, TIME OF | | | OPERATION UNDER THE AMOUNT OF FUEL ETC. PLEASE SEE THE | | | SPECS/CUT SHEETS SUBMITTED CONTAIN MULTIPLE UNITS AND | | | NO REVIEW FOR CODE COMPLIANCE OF THE UNIT FOR EACH | | | BUILDING BASED ON THE NUMEROUS PUMPS SUBMITTED. PLEASE | | | ALSO SEE MISSING FIRE PUMP CONTROLLER SPECS. PLEASE | | | ALSO SEE MISSING THE RELEVANT CODES ON FP SHEETS. | | | PLEASE KNOW BASED ON THE PLANS SUBMITTED AND SPEC/CUT | | | SHEETS SUBMITTED, REVIEW FOR COMPLIANCE CAN NOT BE DONE | | | AT THIS TIME. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE ELECTRICAL RISER SHOULD "NOTE" FIRE PUMP | | | AS DIESEL AS NOTED ON FP SHEETS. | | | PLEASE SUBMIT ALL MANUFACTURES SPEC/CUT SHEETS FOR FIRE | | | PUMP CONTROLLER AS REVIEW FOR CODE COMPLIANCE UNDER | | | 2003 NFPA-20 IS REQUIRED. | | | PLEASE ALSO SUBMIT ALL MANUFACTURES SPECS/CUT SHEETS | | | FOR FUEL TANK. | | | PLEASE SEE NFPA-20 9.6.2.2 AS THE FUEL CAPACITY IS | | | REQUIRED TO BE SIZED BASE ON THE 100% RATED LOAD FOR A | | | MIN OF 8HRS, OR TIME SO DETERMINED BY THE FIRE | | | MARSHAL'S OFFICE DEPENDING ON OCCUPANCY. | | | FUEL SYSTEMS WILL BE UNDER OTHER TRADE REVIEW(S). (FIRE | | | AND MECH). | | | | | | 11) NOTE: NO, RESPONSE MENTIONS THIS WAS DONE, HOWEVER | | | PLEASE SEE UNIT PANEL SCHEDULES AND HOUSE PANEL | | | SCHEDULE DOES NOT CONTAIN AND CONDUCTOR SIZES. PLEASE | | | KNOW BASED ON COMMENTS ABOVE WITH RESPECT TO AREA | | | DESIGNATIONS, CIRCUITING MISSING ON PLANS, REVIEW OF | | | THIS CAN NOT BE DONE AT THIS TIME.408.4 , FBC 104.1.2 | | | ADMINSECTION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INCLUDE ALL MINIMUM CONDUCTOR SIZES ON ALL | | | PANELS, UNITS AND HOUSE PANELS. REVIEW FOR THESE ITEMS | | | OF CODE COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | 310.16, 240.4,215.5 | | | | | | 12) NOTE:NO, AS CIRCUITING FOR THIS BUILDING IS NOT | | | COMPLETE AT THIS TIME, THE OVER CURRENT PROTECTIVE | | | DEVICES CAN NOT BE VERIFIED AT THIS TIME. THIS COMMENT | | | WAS MAINLY FOR THE OCP DEVICES WHICH WERE BEING SHOWN | | | ON BUILDING #1'S PLANS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE GARAGE/HOUSE LIGHTING BEING INDICATED ON 30A | | | AND 50A CIRCUITS. | | | PLEASE SEE CODE DOES LIMIT THE OCP FOR UNIT FIXTURES | | | FOR PROTECTION OF FIXTURES ON A BRANCH CIRCUIT. PLEASE | | | ADJUST CIRCUITING AS NEEDED. | | | PLEASE ALSO SEE A FIXTURE SCHEDULE CONTAINING WATTAGES, | | | VOLTAGES ETC WAS NOT SUBMITTED. | | | PLEASE VERIFY IF THESE UNIT FIXTURES ARE RATED TO HAVE | | | OCP AT ABOVE MENTIONED. | | | 240.4, 310.16 ETC | | | | | | 13) NOTE: OK, HOWEVER SEE NOTES. | | | | | | 14) NOTE:NO/OK, PLEASE SEE PART OF THIS COMMENT SEEMS | | | TO HAVE BEEN ADDRESSED, HOWEVER PLEASE SEE NOTES ON | | | RISER AND RISER NOTES WHICH STILL DO NOT CORRELATE. | | | PLEASE SEE SEVERAL NOTE #1'S, YET ON RISER NOTES NOT | | | ALL OF THESE NOTE #1'S CAN POSSIBLY APPLY. PLEASE | | | ADJUST ALL NOTE SON RISER AND NOTES NOTED AS RISER | | | NOTES. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | , PLEASE SEE PLEASE SEE MAX OCP TO BE SIZED FOR | | | PANELS/EQUIPMENT BEING FED BY SAID OCP. | | | PLEASE SEE MANY UNIT PANELS ARE SHOWN AS 100A MLO, WITH | | | 125A OCP AS LISTED ON RISER ETC. | | | PLEASE ALSO SEE RISER NOTE #4 WHICH INDICATES 125A | | | 2-POLE ETC, HOWEVER PLEASE SEE RISER AS THIS NOTE #4 | | | COULD NOT BE LOCATED. (APPEARS TO BE MISPRINTED FOR | | | "NOTE#7" ON RISER) 240.4,408,310.16,215.5 ETC. | | | | | | 15) NOTE: N/A, NOT PART OF THESE PLANS FOR THIS | | | BUILDING. SEE NEW NOTES. | | | | | | 16) NOTE: N/A, NOT PART OF THESE PLANS FOR THIS | | | BUILDING. SEE NEW NOTES. | | | | | | 17) NOTE: N/A, NOT PART OF THESE PLANS FOR THIS | | | BUILDING. SEE NEW NOTES. | | | | | | 18) NOTE: NO/OK, SOME SHEETS SHOW NOTE, HOWEVER NOT ALL | | | FOR UNITS. CIRCUITING IS NOT YET COMPLETE TO REVIEW | | | THESE FOR CODE COMPLIANCE. PLEASE LABEL ALL CIRCUITS ON | | | PANEL SCHEDULE WHICH CONTAIN AFCI PROTECTION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THESE SHEETS ALSO REFERENCE "ARC FAULT" | | | PROTECTION FROM THE 1999 NEC, WHICH ONLY REQUIRED | | | PROTECTION OF RECEPTS. | | | PLEASE SEE THE 2002 NEC WHICH REQUIRES PROTECTION FOR | | | ALL "OUTLETS" IN BEDRMS. THIS IS INCLUSIVE OF RECEPTS, | | | LTS, FANS, SMOKE DETECTORS ETC. PLEASE SEE NOTE ON UNIT | | | PLANS AND ADJUST. | | | | | | 19) NOTE:THIS IS UNCLEAR AT THIS TIME, AS PERMIT | | | APPLICATION FOR BUILDING #3 INDICATES 450 UNITS, YET | | | METER CALCULATIONS CONTAINS NOTE OF 40 METERS FOR EACH | | | METER CENTER. PLEASE CORRELATE PLANS, PERMIT | | | APPLICATIONS AND ADJUST PLANS AS NEEDED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CORRELATE LOADS, UNITS, PANELS, AND | | | BUILDING/METER LOAD CALCULATIONS: | | | A) PLEASE SEE PANEL SCHEDULE/LOAD CALCULATIONS FOR UNIT | | | "B-3" SHOWN ON | | | 16.26, HOWEVER THIS UNIT TYPE OR LOADS COULD NOT BE | | | LOCATED ON BLDG LOAD CALCULATIONS ON 16.25? | | | B) PLEASE ALSO SEE THE SAME COMMENT ABOVE FOR UNIT | | | "C-2" WHICH IS ALSO SHOWN ON | | | 16.26 BUT NOT IN CALCS ON 16.25?? | | | ** PLEASE ADJUST ALL AS NEEDED. | | | | | | 20) NOTE: OK, HOWEVER STILL NOT ADDED TO RISER, ONLY | | | SHOWN IN GROUNDING DETAIL. PLEASE EXPLAIN RATIONAL OF | | | TWO GROUNDING ELECTRODE SYSTEMS SHOWN? | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INCLUDE THE REQUIRED FOOTER STEEL ON THE | | | GROUNDING ELECTRODE RISER DETAIL. PLEASE ALSO SHOW ON | | | RISER. | | | 250.50. | | | | | | 21) NOTE: NO, PREVIOUS NOTE REQUESTED A NOTE/DETAIL | | | WHICH WOULD ACTUALLY PROVIDE A LITTLE MORE INFORMATION | | | FOR THIS REQUIREMENT. PLEASE EXPAND ON NOTE. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE PROVIDE A DETAIL/NOTE FOR ALL RACEWAY SEALS AS | | | REQUIRED PER | | | 230.8 | | | | | | 22) NOTE: N/A. | | | | | | 23) NOTE: N/A. | | | | | | 24) NOTE: N/A | | | | | | 25) NOTE: OK. | | | | | | 26) NOTE: OK. | | | | | | 27) NOTE: OK. | | | | | | 28) NOTE: NO, PLEASE SEE THE 2001 FBC 905.2 WHICH DOES | | | NOT MENTION THE EXCEPTION AS PERMITTED BY NFPA-72. THE | | | MORE RESTRICTIVE SHALL APPLY. PLEASE SEE NEW NOTES FOR | | | THESE DEVICES AND CIRCUITING. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | SMOKE DETECTORS ARE REQUIRED INSIDE AND OUTSIDE ALL | | | SLEEPING ROOMS. | | | PLEASE SEE 2002 NFPA-72 11.5.3.1 | | | PLEASE ADJUST NOTE FOR SD'S ON PLANS AS | | | SD'S ARE REQUIRED 3' FROM BATH/KITCHEN DOORS, 3' FROM | | | SUPPLY AIR DIFFUSERS, 5' FROM R/A GRILLES AND 20' FROM | | | KITCHEN COOKING APPLIANCES. W/ EXCEPTIONS FOR DISTANCES | | | FROM COOKING APPLIANCES. (PHOTO-ELECTRIC AND RESETTING | | | TYPE) | | | ** PLEASE SEE PREVIOUS NOTES WITH RESPECT TO ARC FAULT | | | PROTECTION OF SD'S AND CIRCUITING. | | | | | | 29) NOTE: N/A PER THIS BUILDING REVIEW. | | | | | | 30) NOTE: NO, AS CIRCUITING IS NOT YET COMPLETE FOR ALL | | | COMMON AREAS THIS CAN NOT BE VERIFIED. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE 700.12E FOR CIRCUITING OF ALL EM/EXT LTS, | | | WHICH REQUIRES THE BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT, SHALL BE THE SAME BRANCH CIRCUIT AS THAT | | | SERVING THE NORMAL LIGHTING IN THE AREA AND CONNECTED | | | AHEAD OF ANY LOCAL SWITCHES. | | | THIS IS NOTED ON SOME SHEETS, HOWEVER CIRCUITING FOR | | | THESE IS NOT SHOWN. | | | 215.5 | | | | | | 31) NOTE: OK. | | | | | | 32) NOTE:NO, PLEASE SE SOME UNITS ARE STILL MISSING | | | GFI RECEPTS TO SERVE KITCHEN COUNTER SPACE AS | | | REQUIRED. | | | UNIT(S) A 1, A-2 ETC. PLEASE GO THROUGH ALL. | | | | | | **PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 210.52C1-C5 FOR REQUIRED GFI RECEPTS ALONG | | | KITCHEN COUNTER SPACE. PLEASE SEE SOME ARE SHOWN ON | | | WHAT APPEARS TO BE A WALL ON THE OTHER SIDE OF THE | | | COUNTER SPACE. | | | PLEASE SEE B-2, B-4ETC. | | | PLEASE SEE OTHER WHICH ARE REQUIRED TO BE WITHIN 2' OF | | | THE END OF THE COUNTER SPACE/FROM SINK EDGE ETC. PLEASE | | | SEE THESE AREAS REDLINED ON SHEETS. | | | | | | 33) NOTE:NO, PLEASE SEE RESPONSE MENTIONS THIS IS FOR | | | SECURITY AND IT IS NOT A PLUG-IN TYPE TRANSFORMER. IF | | | THIS IS NOT A PLU-IN TYPE, PLEASE INDICATE ON PLANS | | | WHAT TYPE IT IS AND/OR WILL BE. PLEASESUBMIT OR | | | RELOCATE THE RECEPTACLES LOCATED ABOVE CLOTHES CLOSET | | | SHELVING OR IN THE NEAR VICINITY AS PREVIOUSLY STATED | | | THIS AHJ HAS SEEN TOO MANY INSTANCE WHERE FIRES HAVE | | | STARTED BASED ON SOME TYPES OF THESE UNITS AND IN THE | | | INTEREST OF LIFE SAFETY AND PROPERTY DAMAGE, THESE WILL | | | NOT BE PERMITTED AS SHOWN IN SOME UNITS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE WHAT APPEARS TO BE A RECEPT LOCATED IN THE | | | CLOTHES CLOSET FOR PERHAPS A LV PLUG-IN TYPE | | | TRANSFORMER? | | | PLEASE KNOW, THE ONLY LOCATION A RECEPT IS PERMITTED IN | | | A CLOTHES CLOSET FOR THIS PURPOSE, MUST BE LOCATED | | | DIRECTLY ABOVE DOOR AWAY FROM COMBUSTIBLES. | | | MANY PLUG-IN TYPE TRANSFORMERS BECOME VERY HOT AND | | | HAVE MELTED OR CAUSED FIRES IN THIS JURISDICTION. | | | PLEASE KNOW, MANY ITEMS IN A CLOTHES CLOSET ARE AN | | | ACCELERANT. | | | THESE RECEPTS MAY BE MOVED TO UTILITY RM IF SO | | | DESIRED. | | | 110.26, 240.24, 90.4 ETC | | | | | | 34) NOTE: OK. | | | | | | 35) NOTE: OK. | | | | | | ** NEW NOTES FOR THIS REVIEW ** | | | | | | 1) NOTE: PLEASE CORRELATE LAYOUT OF THE BUILDING FOR | | | ALL ROOMS AND AREAS. PLEASE SEE THE ELECTRICAL PLANS DO | | | NOT CORRELATE WITH THE ARCHITECTURAL SHEETS AND THE | | | FIRE SPRINKLER SHEETS ALSO HAVE SOME AREAS WHICH DO NOT | | | CORRELATE WITH EITHER. PLEASE SEE FOR INSTANCE THE FIRE | | | PUMP ROOM LAYOUT. | | | | | | 2) NOTE: PLEASE CORRELATE HOUSE PANEL DESIGNATION ON | | | PLANS WITH THE ACTUAL HOUSE PANEL DESIGNATION ON PANEL | | | SCHEDULE. | | | 408.4. | | | | | | 3) NOTE: PLEASE SEE THE THRESHOLD INSPECTION PLANS | | | SUBMITTED ALL CONTAIN A RAISED SEAL OVER A PHOTO-COPIED | | | SIGNATURE FROM THE ENGINEER. PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 AND FLORIDA STATUTES | | | 471.025 AS AN ORIGINAL SIGNATURE IS REQUIRED. PLEASE | | | KNOW THESE MAY BE RETAINED BY THIS OFFICE FOR POSSIBLE | | | REVIEW FROM THEFLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS. IF THERE ARE ANY QUESTIONS ON THIS PLEASE | | | CONTACTTHIS OFFICE ORTHE BOARD. | | | **THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER TRADE. | | | | | | 4) NOTE: PLEASE SEE NFPA-72 DEFINITIONS FOR SMOKE | | | DEVICES. IF THESE ARE INDEED (SD) FOR SMOKE DETECTORS | | | THEN THEY WOULD DETECT AND CAUSE AN ALARM TO HORN/SIREN | | | DEVICE OF SOME TYPE. PLEASE SEE PLANS CALL FOR THESE AS | | | 120V UNITS, WHICH IF (SA) SMOKE ALARMS WHICH WOULD | | | DETECT AND SOUND, THEN THE DESIGNATIONS NEED TO BE | | | ADJUSTED ALONE WITH ALL NOTES WHICH CURRENTLY STATE | | | SMOKE DETECTORS. PLEASE KNOW THIS WAS NOT A COMMENT ON | | | THE PREVIOUS REVIEW, HOWEVER AS INFORMATION WAS GIVEN | | | FROM NFPA DIRECTLY, PLANS MUST CONTAIN THE CORRECT | | | DESIGNATIONS. | | | | | | 5) NOTE: PLEASE SEE THE BASE FA SYSTEM SHALL BE SHOWN | | | AND ALL HORN/STROBE DEVICES SHALL STATE THE MINIMUM | | | LEVELS AS REQUIRED PER FBC 11-4.28.1, .2, AND .3(4). | | | THIS WAS NOT PART OF THE ELECTRICAL REVIEWERS REVIEW | | | WHEN PLANS WERE SUBMITTED PREVIOUSLY HOWEVER THIS HAS | | | NOW BECOME PART OF THE ELECTRICAL REVIEWERS REVIEW. | | | PLEASE SHOW. | | | | | | 6) NOTE: PLEASE CLARIFY STAIRS SHOWN ON SOME UNITS. | | | PLEASE SEE MISSING WHAT WOULD BE EGRESS LIGHTING AND | | | CONTROLS IF INSIDE UNIT AND/OR OUTSIDE UNIT. PLEASE SEE | | | NEC 210.70, LS 101 7.8, (7.9 WHERE APPLICABLE). | | | | | | 7) NOTE: PLEASE SEE SEVERAL HOUSE CIRCUITS AS NOTED | | | ABOVE WITH RESPECT TO CORRELATION OF CIRCUITING SEEM TO | | | BE INDICATE ON THESE PLANS TO PANELS WHICH WOULD BE ON | | | OTHER BUILDINGS? PLEASE SEE MISSING TRASH COMPACTOR AS | | | ONE ITEM ALONE. | | | 240.4, 310.16, 408.4, ETC | | | | | | 8) NOTE: PLEASE SEE NOTES ABOVE ON PREVIOUS REVIEW AND | | | SECOND REVIEW NOTES WITH RESPECT TO ROOM/AREA | | | DESIGNATIONS. PLEASE SEE 210.52B1, 210.11C1 AND 220.16 | | | FOR DINING ROOMS, DINING AREAS, BREAKFAST AREAS, | | | KITCHEN AREAS AND THE LIKE. PLEASE SEE THAT SOME | | | RECEPTS ARE BEING SHOWN IN AREAS WHICH WOULD APPEAR TO | | | BE AREAS OF THE LIKE AS REFERENCED ABOVE, HOWEVER SOME | | | OF THESE RECEPTS ARE BEING SHOWN ON LIGHTING CIRCUITS | | | OF 15A'S ETC. | | | PLEASE ADJUST PLANS FOR PREVIOUS NOTE AND THIS NOTE. | | | | | | 9) NOTE: PLEASE SEE SHEET FOR ELECTRICAL FOR 3RD AND | | | 4TH FLOORS WHICH ARE SHEETS LABELED AS AP P16.06 FOR | | | PLUMBING. PLEASE CORRECT FBC 104.2.1.2 | | | | | | 10) NOTE: PLEASE PROVIDE NOTE ON FIRST FLOOR MAIN | | | ELECTRICAL ROOM PLANS WHICH WILL REQUIRE DOOR TO | | | CONTAIN PANIC HARDWARE. | | | 110.26/90.4 | | | | | | 11) NOTE: PLEASE SEE THE VOLTAGE DROP FOR 30A CU'S, AT | | | THIS TIME CAN NOT BE VERIFIED. PLEASE SEE SOME UNITS | | | INDICATE #10 ALREADY YET THESE WILL BE OVER 75FT AND | | | THERE IS NO NOTE FOR THESE UNITS TO UPGRADE TO #8 OR ? | | | PLEASE ADJUST AND PROVIDE ADDITIONAL INFORMATION. FBC | | | 104.2.1.2, NEC 310.16, 240.4 ETC. | | | | | | 12) NOTE: PLEASE SEE NOTES ABOVE WHICH REQUESTS FOR THE | | | RISER NOTES TO CORRELATE WITH THE DESIGNATIONS ON | | | RISER. PLEASE SEE NOTE #1. | | | 104.2.1.2 FBC ADMIN SECTION. | | | | | | 13) NOTE: PLEASE PROVIDE A DETAIL FOR THE ROOF TOP | | | DISCONNECT AS BEING NOTED AND HOW THIS WILL BE MOUNTED? | | | (NOT TO UNIT) | | | 440.11. THIS CAN BE A TYPICAL DETAIL. | | | | | | 14) NOTE: PLEASE SEE ATTACHED COPY OF FLORIDA STATUTES | | | 553.80(2)(B) WITH RESPECT TO REPEAT CODE COMPLIANCE | | | COMMENTS. THIS IS ONLY A NOTICE GIVEN AT THIS TIME. | | | | | | 15) NOTE: PLEASE SEE MISSING FIRST FLOORELECTRICAL | | | FOR UNITS WITH STAIRS. 210.70,210.52 ETC | | | | | | *** PLEASE KNOW THAT THERE MAY BE NEW COMMENTS ON THE | | | NEXT REVIEW DUE TO INFORMATION NOT SUBMITTED OR | | | COORDINATION OF PLANS/INFORMATION SUBMITTED FOR REVIEW | | | | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER REVIEWER(S) WHICH | | | MAY HAVE AN AFFECT ON ELECTRICAL PLANS. | | | | | | ** PLEASE KNOW, A TYPE WRITTEN RESPONSE LETTER FROM | | | DESIGN PROFESSIONAL(S) FOR EACH COMMENT ON HOW/WHERE | | | CORRECTIONS ARE MADE OR IF COMMENTS ON REVIEW WILL HELP | | | IN EXPEDITING THE PLAN REVIEW PROCESS. THIS WAS DONE, | | | AND SHOULD BE DONE FOR THIS REVIEW AS WELL. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-26 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-25 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2005-12-26 00:00:00 | ************ UNSAT ************ | | | | | | COURTNEY LAKES | | | N. CONGRESS. | | | | | | | | | 1)NOTE: PLEASE SUBMIT COMPLETED PLANS | | | BOUND TOGETHER IN APPROPRIATE FASHION. | | | PLEASE SEE ALL SHEETS WERE SUBMITTED | | | LOOSELY AND NOT IN BOUND STES. | | | | | | 2)NOTE: PLEASE BE SURE ALL PLANS ARE | | | SIGNED, DATED AND SEALED BY ALL DESIGN PROFESSIONALS AS | | | REQUIRED UDNER FS | | | 481.221 AND 471.025. | | | (PLEASE SEE A-SHEETS, ONLY SIGNED). | | | | | | 3)NOTE: PLEASE BE SURE TO CORRECT THE | | | CURRENT NEC/ NFPA-70 IN EFFECT. | | | PLEASE KNOW, AS OF JULY 1ST, 2003 THE | | | STATE OF FLORIDA ADOPTED THE 2002 | | | NFPA-70 (NEC). PLANS REFERENCE 1999. | | | PLEASE SEE SOME ELECTRICAL COMMENTS | | | WHICH WILL AFFECT THIS. | | | PLEASE SEE NEXT COMMENT WITH RESPECT TO | | | PERMITS APPLIED FOR UNDER THE 2001 FBC | | | BEFORE OCT 1ST, 2005 AND PERMITS ON OCT | | | 1ST, 2005. | | | | | | 4)NOTE: PLEASESEE THAT THREE SEPARATE | | | PERMIT APPLICATIONS WERE SUBMITTED AND | | | NOTED FOR BLDG'S 1,2 AND 3, HOWEVER | | | PLANS SHOWS BLDG TYPES 1.2&3 STRUCTUALLY | | | ONLY ONE BUILDING. | | | PLEASE SEE PERMIT APPLICATIONS ALL | | | REFLECT THIS ONE 450 UNIT BLDG. | | | PLEASE SEE THIS CONTRADICTS THE "PHASING | | | PLAN" SUBMITTED ON A1.04 AS THIS PHASING | | | PLAN INDICATES WORK ON BLDGS 4 AND 5 | | | BEFORE COMPLETION OF BLDGS 1, 2 AND 3. | | | PLEASE SEE COMMENTS FROM BLDG, FIRE AND | | | OTHER REVIEWERS, ASCERTIFICATES OF | | | OCCUPANCY(CO'S) FOR THESE CAN NOT BE | | | GRANTED IN THIS ORDER AS THE FIRST | | | "STRUCTURED BLDG"(1,2&3) WOULD NOT BE | | | COMPLETE. | | | PLEASE ALSO SEE COMMENTS WITH RESPECT TO "TEMPORARY | | | CO'S" WHICH MAY ALLOW | | | OCCUPANCY OF SOME PARTS OF BLDGS, | | | HOWEVER THESE TCO'S ARE ONLY GOOD FOR 30 | | | DAYS AND A MAX OF 3 TCO'S MAY ONLY BE | | | GRANTED BY THE BLDG OFFICAL. | | | PLEASE KNOW, IN ANY CASE, ALL LIFE | | | SAFTEY, FIRE PROTECTION SYSTEMS, FIRE | | | SPRINKLERS (FULLY CHARGED),ELECTRICAL | | | SYSTEMS ETC SHALL BE COMPLETE IN THE | | | BASE BLDG FOR BLDG TYPE 1, 2& 3 BEFORE A | | | TCO,/CO CAN BE GRANTED. | | | ************************************* | | | ALSO NOTED THAT BLDG'S TYPE 4 AND 5 | | | WHICH ARE SEPARATE STRUCTURES AND | | | INDEPENDANT OF EACH OTHER WERE NOT | | | SUBMITTED FOR PERMIT. | | | PLEASE SEE ALL PERMITS SUBMITTED AFTER | | | OCT. 1ST, 2005 SHALL FALL UNDER THE | | | 2004 FBC, WITH ALL OTHER CODES ADOPTED | | | BY SAID CODE AND STATE OF FLORIDA. | | | ************************************ | | | PLEASE SEE COMMENTS FROM OTHER | | | REVIEWER(S) WITH RESPECT TO THIS. | | | ************************************* | | | PLEASE ALSO SEE NEXT COMMENT WITH | | | RESPECT TO THE MAINS, SERVICES, AND | | | METER RMS AS PROPOSED. | | | ** SEE ALL NOTES FROM ALL REVIEWERS | | | WHICH MAY ALSO AFFECT THIS SEQUENCE OF CONSTUCTION. | | | | | | 5)NOTE: PLEASE SEE METER RMS AS SHOWN | | | WOULD BE OK, HOWEVER STRUCTURE AS SHOWN | | | FOR BLDG TYPE 1,2 AND 3 (ONE BLDG) WOULD | | | REQUIRE MAINS TO BE GROUPED. | | | 90.4,230.2,230.70,230.72,230.76,230.79 | | | ETC. | | | BLDG'S LARGE ENOUGH TO CONTAIN MORE THAN | | | ONE SERVICE AT SEPARATE LOCATIONS SHALL | | | BE DIVIDED INTO SECTIONS AND SHALL HAVE | | | THOSE SECTIONS DIVIDED BY "FIRE WALLS". | | | PLEASE SEE FBC FOR DEFINITION OF "FIRE | | | WALLS". | | | PLEASE KNOW, STRUCTURE CONSTRUCTED AS | | | SHOWN IN PLANS, WOULD REQUIRE MAIN | | | DISCONNECTS GROUPED, WHICH WOULD THEN | | | IN-TURN FEED METER ROOMS. | | | OTHER DESIGN CHANGES IN THE "ONE BLDG" | | | MAY ALSO PERMIT INDIVIDUAL SERVICES. | | | PLEASE SEE BLDG TYPE #4 AND #5 ARE SHOWN | | | AS SEPARATE BLDGS WITH STAND ALONE | | | SERVICES AND ALL MAINS ARE GROUPED. | | | PLEASE KNOW THAT BLDGS 4 AND 5 WILL HAVE | | | REVIEWS DONE UNDER THOSE PERMIT | | | APPLICATIONS. | | | ** PLEASE SEE SOME OF THESE COMMENTS | | | WOULD ALSO APPLY. | | | | | | 6)NOTE: PLEASE COMPLETE ALL CIRCUITING | | | ON PLANS IN ORDER TO REVIEW CODE | | | COMPLIANCEFOR AREAS OF UNITS AND | | | COMMON AREAS. | | | | | | 7)NOTE: PLEASE PROVIDE ROOM AND AREA | | | DESIGNATIONS ON PLANS, INCLUSIVE OF ALL | | | UNITS AND COMMON AREAS. | | | REVIEW FOR SOME CODE COMPLIANCE ITEMS | | | CAN NOT BE DONE AT THIS TIME. | | | | | | 8)NOTE: PLEASE PROVIDE COMPLETE | | | PHOTOMETRICS FOR ALL COMMON AREAS, | | | GARAGE AREA,COMMON AREA CORRIDORS, | | | STAIR TOWERS ETC. | | | PLEASE SEE 2003 NFPA-101 7.8.1.3 AND | | | 7.9.2 WHICH REQUIRES A MIN OF 10FT | | | CANDLES FOR STAIR TOWERS UNDER NORMAL | | | OPERATION AS WALK SURFACE AND A MIN OF | | | 1FT CANDLE AT WALK SURFACE UNDER | | | EMERGENCY CONDTIONS. PLEASE ALSO SEE | | | OTHER WALK AREAS, GARAGE, CORRIDORS ETC | | | AND THE MIN OF 1FT CANDLE. | | | **PLEASE SEE PALM BEACH COUNTY SECURITY | | | CODE ORDIANCE WITH RESPECT TO MIN DESIGN | | | OF PARKING LOT LIGHTING LEVELS UNDER | | | NORMAL CONDITIONS. (ONLY NOTED FOR | | | DESIGN)NOT REQUIRED. PLEASE SEE ANY | | | REQUIREMENTS FROM INS CARRIER WHICH | | | REQUIE A MIN LEVEL OF LIGHTING. | | | ** PLEASE SEE PHOTOMETRICS OR SITE PLAN | | | WAS NOT SUBMITTED FOR PROPOSED POOL | | | AREA. THE POOL STRUCTURE IS REQUIRED TO | | | BE UNDER A SEPARATE PERMIT. PLEASE KNOW, | | | THE PHOTOMETRICS FOR POOL AREA WILL BE | | | REQUIRED AND WILL ALSO BE REQUIRED TO BE | | | REVIEWED AND STAMPED BY THE PALM BEACH | | | COUNTY HEALTH DEPT FOR ANY PROPOSED | | | NIGHT-TIME SWIMMING. | | | | | | 7)NOTE: PLEASE SEE NO "ELECTRICAL | | | SITE-PLAN" WAS SUBMITTED FOR ANY SITE | | | LIGHTING, LANDSCAPE LIGHTING ETC. | | | PLEASE KNOW, IF NOT SUBMITTED UNDER THIS | | | PERMIT AND VALUES ADJUSTED ACCORDINGLY, | | | SSEPARATE PERMIT , PLANS AND FEES WILL | | | BE REQUIRED FOR ALL SITE LIGHTING, | | | LANDSCAPE LIGHTING WORK. | | | ** ALSO NOTE: IN THAT COMPLETE WIND | | | LOADING CALCULATIONS FOR LT POLES | | | INCLUSIVE FO THE ATTACHMENT OF LT | | | FIXTURES WILL BE REQUIRED TO BE | | | SUBMITTED WITH PLANS AND PERMIT | | | APPLICATION FOR REVIEW. | | | | | | 8)NOTE: PLEASE INCLUDE AN EMERGENCY | | | BATTERY BACK UP LT OF SOME SORT IN ALL | | | ELECTRICAL ROOMS, FIRE PUMP ROOM, | | | ELEVATOR MACHINE RMS. SOME ARE SHOWN, | | | BUT NOT ALL. | | | 7.8,7.9,700.16 ETC | | | | | | 9)NOTE: PLEASE SEE 620.23, AND 620.24 | | | FOR REQUIRED DEDICATED BRANCH CIRCUITS | | | FOR ELEVATOR PITS, AND ELEVATOR MACHINE RMS/EQUIPMENT | | | AREAS. | | | PLEASE ADJUST HOUSE PANELS AS NEEDED. | | | | | | 10)NOTE: PLEASE SEE ELECTRICAL RISER | | | SHOULD "NOTE" FIRE PUMP AS DIESEL AS | | | NOTED ON FP SHEETS. | | | PLEASE SUBMIT ALL MANUAFCTURES SPEC/CUT | | | SHEETS FOR FIRE PUMP CONTROLLER AS | | | REVIEW FOR CODE COMPLIANCE UNDER 2002 | | | NFPA-20 IS REQUIRED. | | | PLEASE ALSO SUBMIT ALL MANUFACTURES | | | SPECS/CUT SHEETS FOR FUEL TANK. | | | PLEASE SEE NFPA-20 9.6.2.2 AS THE FUEL | | | CAPACITY IS REQUIRED TO BE SIZED BASE ON | | | THE 100% RATED LOAD FOR A MIN OF 8HRS, | | | OT TIME SO DETERMIND BY THE FIRE | | | MARSHAL'S OFFICE DEPENDING ON OCCUPANCY. | | | FUEL SYSTEMS WILL BE UNDER OTHER TRADE | | | REVIEW(S). (FIRE AND MECH). | | | | | | 11)NOTE: PLEASE INCLUDE ALL MIN | | | CONDUCTOR SIZES ON ALL PANELS,UNITS AND | | | HOUSE PANELS. REVIEW FOR THESE ITEMS OF | | | CODE COMPLIANCE CAN NOT BE DONE AT THIS | | | TIME. 310.16,240.4,215.5 | | | | | | 12)NOTE: PLEASE SEE GARAGE/HOUSE | | | LIGHTING BEING INDICATED ON 30A AND 50A | | | CIRCUITS. | | | PLEASE SEE CODE DOES LIMIT THE OCP FOR | | | UNIT FIXTURES FOR PROTECTION OF FIXTURES | | | ON A BRANCH CIRCUIT. | | | PLEASE ADJUST CIRCUITING AS NEEDED. | | | PLEASE ALSO SEE A FIXTURE SCHEDULE | | | CONTAINING WATTAGES, VOLTAGES ETC WAS | | | NOT SUBMITTED. | | | PLEASE VERIFY IF THESE UNIT FIXTURES ARE | | | RATED TO HAVE OCP AT ABOVE MENTIONED. | | | 240.4, 310.16 ETC | | | | | | 13)NOTE: PLEASE CORRELATE ALL OCP | | | DEVICES FOR UNITS AND FEEDERS BEING | | | LISTED IN "RISER NOTES". | | | PLEASE SEE SOME FEEDERS SHOWN AS #4'S ON | | | 125A BREAKER? | | | SEE 310.16,240.4 | | | PLEASE SEE OCP FOR ALL UNITS IS LISTED | | | AS 125A'S. | | | SEE NEXT COMMENT. | | | | | | 14)NOTE: PLEASE SEE MAX OCP TO BE SIZED | | | FOR PANELS/EQUIPMNET BEING FED BY SAID | | | OCP. | | | PLEASE SEE MANY UNIT PANELS ARE SHOWN AS | | | 100A MLO, WITH 125A OCP AS LISTED ON | | | RISER ETC. | | | PLEASE ALSO SEE RISER NOTE #4 WHICH | | | INDICATES 125A 2-POLE ETC, HOWEVER | | | PLEASE SEE RISER AS THIS NOTE #4 COULD | | | NOT BE LOCATED. (APPEARS TO BE | | | MISPRINTED FOR "NOTE#7" ON RISER) | | | 240.4,408,310.16,215.5 ETC. | | | | | | 15)NOTE: PLEASE SEE 16.26 AND 16.27 | | | WHICH CONTAIN THE SAME EXACT "HOUSE | | | PANELS" ?? H1, H1A , H2, AND H2A. | | | PLEASE SEE SHEET 16.27 MAY BE DELETED IF | | | PANELSCHEDULES FOR "CA" AND"CB" ARE | | | MOVED TO 16.26. | | | | | | 16)NOTE: PLEASE CORRELATE LOADS SHOWN | | | FOR H1A WITH LOAD SHOWN ON H1. | | | THIS DOES NOT MATCH. | | | | | | 17)NOTE: PLEASE CORRELATE LOADS ON PANEL | | | H2A WITH LOADS SHOWN ON H2> | | | THESE ALSO DO NOT MATCH. | | | | | | 18)NOTE: PLEASE SEE THESE SHEETS ALSO | | | REFERENCE "ARC FAULT" PROTECTION FROM | | | THE 1999 NEC, WHICH ONLY REQUIRED | | | PROTECTION OF RECEPTS. | | | PLEASE SEE 2002 NEC WHICH REQUIRES | | | PROTECTION FOR ALL "OUTLETS" IN BEDRMS. | | | THIS IS INCLUSIVE OF RECEPTS, LTS, FANS, | | | SMOKE DETECTORS ETC. | | | PLEASE SEE NOTE ON UNIT PLANS AND | | | ADJUST. | | | | | | 19)NOTE: PLEASE CORRELATE LOADS , UNITS, | | | PANELS, AND BUILDING/METER LOAD | | | CALCULATIONS: | | | A) PLEASE SEE PANEL SCHEDULE/LOAD | | | CALCULATIONS FOR UNIT "B-3" SHOWN ON | | | 16.26, HOWEVER THIS UNIT TYPE OR LOADS | | | COULD NOT BE LOCATED ON BLDG LOAD | | | CALCULATIONS ON 16.25? | | | B)PLEASE ALSO SEE THE SAME COMMENT ABOVE | | | FOR UNIT "C-2" WHICH IS ALSO SHOWN ON | | | 16.26 BUT NOT IN CALCS ON 16.25?? | | | ** PLEASE ADJUST ALL AS NEEDED. | | | | | | 20)NOTE: PLEASE INCLUDE THE REQUIRED | | | FOOTER STEEL ON THE GROUNDING ELECTRODE | | | RISER DETAIL. | | | PLEASE ALSO SHOW ON RISER. | | | 250.50. | | | | | | 21)NOTE: PLEASE PROVIDE A DETAIL/NOTE | | | FOR ALL RACEWAY SEALS AS REQUIRED PER | | | 230.8 | | | | | | 22)NOTE: PLEASE SEE RISER WHICH SHOWS A | | | POOL PANEL BEING FED FROM PANEL "CA", | | | HOWEVER PANEL "CA" , DOES NOT SHOW SUCH | | | PANEL. | | | 215.5 | | | | | | 23)NOTE: PLEASE PROVIDE "FUTURE" POOL | | | PANEL ON RISER AND PANEL SCHEDULE. | | | 215.5 | | | | | | 24)NOTE: PLEASE SEE RISER NOTE #12 WHICH | | | IS SHOWN FOR FEED FROM PANEL "CA" TO | | | PANEL "CB". THIS IS SHOWN AS 500MCM'S, | | | ALTHOUGH OCP ON CA IS ONLY SHOWN AS | | | 200A'S? THIS IS PERMITTED, HOWEVER THE | | | 200A DEVICE MAY NOT ACCEPT 500MCM'S. | | | 215.5 | | | | | | 25)NOTE: PLEASE SEE REDLINED ITEMS ON | | | PLANS FOR "EQUIPMENT GROUNDING | | | CONDUCTORS" BEING SHOWN BEFORE THE FIRST | | | MEANS OF DISCONNECT. | | | PLEASE SEE 250.6, 250.24. | | | PLEASE SEE HOUSE METER #2, SEE RISER | | | NOTE #12 AND #13 SHOWS AN "EQUIPMENT | | | GROUNDING" CONDUCTOR WHICH IS | | | PARALLELING THE NEUTRAL. | | | | | | 26)NOTE: PLEASE SEE MIN OCP FOR WATER | | | HEATERS TO BE SIZED AT 125%.424.13 | | | PLEASE SEE UNITS CONTAINING 5KW WH @ | | | 208V'S WOULD INCREASE THIS BRKR TO A | | | 2-P35A. PLEASE ALSO ADJUST ANY AWG PER 310.16,240.4 | | | | | | 27)NOTE: PLEASE SEE UNIT LOAD | | | CALCULATIONS SHOWS THE LOADS FOR A/C'S | | | AFTER THE PERMITTED DERATING, HOWEVER | | | PLEASE SHOWLOADS FOR THESE BEFORE | | | DERATING. | | | PLEASE BE SURE TO CORRELATE WITH LOADS | | | FOR COOLING AND HEAT ON MECHANICAL PLAN. | | | 215.5 | | | | | | 28)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | PLEASE SEE 2002 NFPA-72 11.5.3.1 | | | PLEASE ADJUST NOTE FOR SD'S ON PLANS AS | | | SD'S ARE REQUIRED 3' FROM BATH/KTICHEN | | | DOORS, 3' FROM SUPPLY AIR DIFFUSERS, 5' | | | FROM R/A GRILLES AND 20' FROM KITCHEN | | | COOKING APPLIANCES. W/ EXCEPTIONS FOR | | | DISTANCES FROM COOKING APPLIANCES. | | | (PHOTOELECTRIC AND RESETTING TYPE) | | | ** PLEASE SEE PRIVIOUS NOTES WITH | | | RESPECT TO ARC FAULT PROTECTION OF SD'S | | | AND CIRCUTING. | | | | | | 29)NOTE: PLEASE SEE ALL RECEPTS IN | | | CLUBHOUSE KITCHEN PER 210.8B3 WHICH | | | REQUIRES ALL 15- AND 20-AMPERE, 125-VOLT RECEPTACLES IN | | | NONDWELLING-TYPE KITCHENS | | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | | APPLIES TO EACH AND EVERY 15- AND | | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | | WHETHER OR NOT THE RECEPTACLE SERVES | | | COUNTERTOP APPLIANCES. | | | | | | 30)NOTE: PLEASE SEE 700.12E FOR | | | CIRCUITING OF ALL EM/EXT LTS, WHICH | | | REQUIRES THE BRANCH CIRCUIT FEEDING THE | | | UNIT EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | THIS IS NOTED ON SOME SHEETS, HOWEVER | | | CIRCUITING FOR THESE IS NOT SHOWN. | | | 215.5 | | | | | | 31)NOTE: PLEASE CLARIFY THE "CT" AS | | | LABLED ALONG KITCHEN RECEPTS. THIS | | | ABBREVIATION COULD NOT BE LOCATED ON | | | SYMBOL LEGEND? | | | | | | 32)NOTE: PLEASE SEE 210.52C1-C5 FOR | | | REQUIRED GFI RECEPTS ALONG KTICHEN | | | COUNTERSPACE. PLEASE SEE SOME ARE SHOWN | | | ON WHAT APPEARS TO BE A WALL ON THE | | | OTHER SIDE OF THE COUNTERSPACE. | | | PLEASE SEE B-2, B-4ETC. | | | PLEASE SEE OTHER WHICH ARE REQUIRED TO | | | BE WITHIN 2' OF THE END OF THE | | | COUNTERSPACE/FROM SINK EDGE ETC. | | | PLEASE SEE THESE AREAS REDLINED ON | | | SHEETS. | | | | | | 33)NOTE: PLEASE SEE WHAT APPEARS TO BE A | | | RECEPT LOCATED IN THE CLOTHES CLOSET FOR | | | PERHAPS A LV PLUG-IN TYPE TRANSFORMER? | | | PLEASE KNOW, THE ONLY LOCATION A RECEPT | | | IS PERMITTED IN A CLOTHES CLOSET FOR | | | THIS PURPOSE, MUST BE LOCATED DIRECTLY | | | ABOVE DOOR AWAY FROM COMBUSTIBLES. | | | MANY PLUG-IN TYPE TRANSFORMERS BECOME | | | VERY HOT AND HAVE MELTED OR CAUSED FIRES | | | IN THIS JURISTICTION. PLEASE KNOW, MANY | | | ITEMS IN A CLOTHES CLOSET ARE AN | | | ACCELERANT. | | | THESE RECEPTS MAY BE MOVED TO UTILITY RM | | | IS SO DESIRED. | | | 110.26, 240.24, 90.4 ETC | | | | | | 34)NOTE: PLEASE SEE RELDINED PLANS FOR | | | ANY RECEPTS WHICH MAY BE REQUIRED PER | | | 210.52 (A-2). MOST ALL SPACING IS OK. | | | | | | 35)NOTE: PLEASE MAKE NOTE FOR ALL MIN | | | FAIR HOUSING ACT REQUIREMENTS FOR DEVICE | | | HEIGHTS. | | | 24 CFR 100.205 | | | | | | ** PLEASE KNOW, SOME REVIEW OF CODE | | | COMPLIANT ITEMS MAY NOT BE DONE AT THIS | | | TIME DUE TO SOME INFORMATION NOT ON | | | PLANS. | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY HAVE AN AFFETC ON | | | ELECTRICAL PLANS. | | | | | | ** PLEASE KNOW, A TYPE WRITTEN RESPONSE | | | LETTER FROM DESIGN PROFESSIONL(S) FOR | | | EACH COMMENT ON HOW/WHERE CORRECTIONS | | | ARE MADE OR IF COMMENTS ON REVIEW WILL | | | HELP IN EXPEDITING THE PLAN REVIEW | | | PROCESS. | | | | | | ** PLEASE KNOW THAT A MEETING TO GO OVER | | | FIRST COMMENTS FOR DESIGN/PHASING OF | | | BLDGWITH ALL REVIEWERS IS SUGGESTED | | | BEFORE PERHAPS SUBMITTING PLANS BACK FOR | | | REVIEW. | | | PLEASE KNOW, ALL REVIEWS AFTER THE 1ST | | | FREE "RE-SUB" IS SUBJECT TO A 10% RESUB | | | FEE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | 2005-12-25 00:00:00 | ONE ROLL IN ELECTRIC FOR REVIEW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-09-28 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-09-28 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2007-09-28 14:25:24 | ****FAILED***** | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON CIVIL DRAWING THE EXACT MAILING | | | ADDRESS, BUILDING NAME, OR NUMBER, YOU TALKING ABOUT 3 | | | PERMITS, PLEASE IDENTIFY EACH BUILDING ON THE DRAWING. | | | 3.PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 4.PLEASE SHOW FINISH FLOOR ELEVATION ON DRAWING . | | | PLEASE EXPLAIN IN DETERMINING FIRST FLOOR ELEVATION, | | | PLEASE SHOW IN YOUR CALCULATION THAT YOU CONSIDERED | | | CENTER LINE OF ROAD , FLOOD ZONE OF THIS SITE,& 5,10, | | | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST | | | FLOOR ELEVATION, PLEASE SHOW ALL THESE IN YOUR STORM | | | WATER CALS.PLEASE ALSO SHOW ON DRAWINGS THE MAXIMUN | | | AND MINIMUM PARKING LOT ELEVATIONS. | | | | | | 5. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE | | | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL | | | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, | | | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE | | | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED | | | IN STORM WATER QUALITY CALCULATIONS. | | | 6. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS.AFTER CONTROL | | | STRUCTURE WHERE STORM WATER GOES?? | | | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN. | | | 8. PLEASE RESUBMIT A COPY OF SFWMD PERMIT,, & GEO TECH | | | REPORT,STORM WATER CALS MUST BE APPROVED FROM 1000 | | | 45TH STREET ENGINEERING SERVICES. | | | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | 10. PLEASE KEEP SEPARATE CIVIL DRAWINGS SO I CAN REVIEW | | | QUICK. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2005-10-31 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-10-31 |
Time |
11:18 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2005-10-31 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2005-10-31 00:00:00 | FAILED: | | | | | | 1. PLEASE SUBMIT CIVIL PLANS FOR OUR | | | REVIEW AND APPROVAL.NOTE THAT CIVIL | | | PLANS FOR THIS WERE REVIEWED UNDER OLD | | | PERMIT APPLICATIONS # 04021308,04021305, | | | 04021300 WHICH EXPIRED.COPY OF THE | | | REVIEW NOTES INCLUDED FOR YOUR USE. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-11-07 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-11-07 |
Time |
15:04 |
Sent To |
|
|
| Notes |
| 2007-11-07 15:04:55 | ***PROVISO*** | | | | | | COMMENTS HAVE BEEN ADDRESSED FROM THE PREVIOUS REVIEW. | | | PLEASE SEE ADDITIONAL COMMENTS: | | | | | | 1) DESIGN CRITERIA REFERS TO NFPA 13 AND SHEET FP 13.02 | | | REFERS TO NFPA 13R IN SHEET NOTES. PLEASE CORRELATE OR | | | EXPLAIN. | | | | | | 2) PLEASE SEE CORRECTION FROM PREVIOUS REVIEW COMMENTS. | | | MULTI-FAMILY RESIDENTIAL BUILDINGS TO COMPLY WITH | | | COMMERCIAL REQUIREMENTS FOR ADDRESSING. MINIMUM OF 6" | | | IN HEIGHT AND 1" IN WIDTH. SEPARATE UNIT CHARACTERS TO | | | COMPLY WITH 3" REQUIREMENT. | | | | | | 3) PLANS DON'T SEEM TO ILLUSTRATE ANY POST INDICATING | | | VALVE DETAIL. A NOTE DOES REFERENCE PIV TAMPER SWITCHES | | | ON SHEET FP 13.10. WHAT MEANS WILL BE PROVIDED WHERE | | | THE STATUS OF (1) BUILDING WON'T IMPACT OTHER | | | BUILDINGS? PLEASE PROVIDE DETAIL AND ILLUSTRATE ON FP | | | SITE PLAN. | | | | | | 4) PLEASE INDICATE IF ANY ELEVATORS WILL MEET | | | REQUIREMENTS FOR STRETCHER ACCESSIBILITY. | | | | | | | | | PLANS WILL BE STAMPED WHEN RETURNED AND ADDRESSED FOR | | | FIRE COMMENTS IN ADDITION TO OTHER REVIEW NOTES. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-02-27 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-02-27 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2007-02-27 15:53:51 | ***DENIED*** | | | | | | IN ORDER TO HELP EXPEDITE THE PLAN REVIEW PROCESS, | | | PLEASE SEE THE FOLLOWING: | | | | | | 1) PLEASE REFER TO THE FIRST FIRE REVIEW COMMENTS. MANY | | | COMMENTS WERE ANSWERED OR ADDRESSED WITH COMMENT NOTED. | | | THIS DOES NOT DEMONSTRATE THAT COMPLIANCE WILL BE MET. | | | IT WOULD BE HELPFUL IF THE CHANGE OR ADDED NOTE IS | | | CLEARLY SHOWN ON DRAWINGS, AND THE CORRECT SHEET NUMBER | | | IS INDICATED. SOME RESPONSES WERE FOUND ON SHEETS THAT | | | WERE DIFFERENT FROM WHAT WAS INDICATED IN THE RESPONSE | | | LETTER. FOR EXAMPLE, COMMENT #1 INDICATES THAT | | | REFERENCE HAS BEEN ADDED TO FP13.17, BUT WAS ACTUALLY | | | FOUND ON A 1.02. PLEASE KNOW THAT IT IS UNDERSTOOD THAT | | | SOME COMMENTS MAY BE ACKNOWLEDGED, BUT SHOULD BE SHOWN | | | ON PLANS TO ELLIMINATE CONFUSION IN THE FUTURE DURING | | | THE INSPECTION PROCESS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW(561) 805-6722 | | | FIRE PREVENTION(561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-12-28 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-12-28 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-12-28 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2005-12-28 00:00:00 | ******DENIED****** | | | | | | 1) NFPA 101 AND NFPA 1, 2003 EDITION | | | SHALL BE REFERENCED. | | | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER SYSTEM | | | WHICH SHALL BE UL CERTIFIED FOR CENTRAL | | | STATION SERVICE. | | | | | | 3) PLEASE NOTE THAT INTENDED SCOPE OF | | | WORK FOR THIS PROJECT IN RELATION TO THE | | | PERMIT APPLICATIONS IS CONFUSING. | | | | | | 4) WHENS PLANS ARE RESUBMITTED, PLEASE | | | ASSURE THAT ALL SHEETS ARE BOUND | | | TOGETHER AND ORGANIZED. | | | | | | 5) CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 6) STAIRS ARE TO BE KEPT UP WITH | | | CONSTRUCTION. | | | | | | 7) TEMPORARY STANDPIPES ARE REQUIRED | | | WHEN THE BUILDING REACHES 3 STORIES OR | | | 30' IN HEIGHT. | | | | | | 8) IN REGARDS TO PHASING, PLEASE BE | | | ADVISED THAT ALL LIFE SAFETY COMPONENTS | | | MUST BE INSPECTED, TESTED AND APPROVED | | | PRIOR TO OCCUPANCY OF BUILDINGS. | | | | | | 9) PARKING AREAS MUST BE IN COMPLIANCE | | | WITH APPLICABLE BUILDING CODES AND NFPA | | | 88A. MINIMUM TWO HOUR SEPARATION TO | | | OTHER PARTS OF BUILDING IS REQUIRED. | | | | | | 10) WET FIRE HYDRANTS TO BE OPERATION | | | PRIOR TO, DURING AND AFTER CONSTRUCTION. | | | | | | 11) PLEASE NOTE THAT ALL LIFE SAFETY | | | EQUIPMENT, FIRE SPRINKLER AND FIRE ALARM | | | AND ALL OTHER BUILDING SERVICES SHALL BE | | | SEPARATE IF BUILDINGS MEET THE CRITERIA | | | FOR SEPARATE STRUCTURES. | | | | | | 12) ALL ACCESS ROADS SHALL BE AT LEAST | | | 20' IN CLEAR , UNOBSTRUCTED WIDTH FOR | | | EMERGENCY VEHICLES, AND SHALL MEET ALL | | | OTHER REQUIREMENTS OF NFPA 1. | | | | | | 13) PLEASE INDICATE ALL LOCATION OF FIRE | | | HYDRANTS. | | | | | | 14) NFPA 13, 2002 EDITION SHALL BE | | | REFERENCED. SHT. A5.01. | | | | | | 15) LOCKING KNOX BOX CAPS ARE REQUIRED | | | ON FIRE DEPARTMENT CONNECTIONS. | | | | | | 16) IN ADDITION TO ELECTRONIC SWITCHES, | | | THE DOUBLE CHECK DETECTOR ASSEMBLIES | | | SHALL BE SECURED WITH A CHAIN AND LOCK. | | | | | | 17) AS NOTED ON SHT, A5.02, FIRE | | | EXTINGUISHERS SHALL BE MOUNTED AT | | | DISTANCES TO SATISFY THE 75' TRAVEL | | | DISTANCE REQUIREMENT. | | | | | | 18) ALL DOORS SHALL SWING IN THE | | | DIRECTION OF TRAVEL WHEN SERVING AREAS | | | WITH OCCUPANT LOADS OF GREATER THAN 50. | | | | | | 19) ELEVATORS TO COMPLY WITH ASME A17.1. | | | | | | 20) PENETRATIONS INTO , AND OPENINGS | | | THROUGH STAIRWELLS SHALL BE LIMITED TO | | | AND IN COMPLIANCE WITH NFPA 101, SECTION | | | 7.1.3.2.1 (6). | | | | | | 21) PLEASE CLARIFY ALL EXIT DISCHARGING | | | FROM STAIRWELLS THAT LEAD DIRECTLY TO | | | THE OUTSIDE. | | | | | | 22) SOME ACHITECTUAL DRAWINGS SHOW | | | STAIRWELL DOORS, AND OTHERS DON'T.??? | | | | | | 23) THIS PERMIT APPLICATION PROCESS | | | ILLUSTRATES 3 BUILDINGS AND OTHER | | | BUILDINGS, 4&5 ARE SHOWN ON PLANS. | | | PLEASE CLARIFY. | | | | | | 24) PLEASE ILLUSTRATE THE TOTAL OCCUPANT | | | LOAD FOR THE CLUBHOUSE. | | | | | | 25) IN ADDITION TO THE ALREADY NOTED | | | REQUIREMENTS FOR ADDRESSING, PLEASE NOTE | | | THAT THE HEIGHT OF THE ADDRESS SHALL BE | | | AT LEAST 3" IN HEIGHT FOR RESIDENTIAL | | | BUILDINGS. | | | | | | 26) PLEASE REFER TO DOOR SCHEDULE AND | | | VERIFY CORRECT AMOUNT OF FIRE RATED | | | DOORS. DOORS SERVINGS AREAS WITH | | | OCCUPANT LOADS GREATER THAN 100 SHALL | | | HAVE PANIC HARDWARE. | | | | | | 27) FIRE PROTECTION SITE PLAN DOESN'T | | | APPEAR COMPLETE ON SHT FP13.01. | | | | | | 28) FIRE DEPARTMENT VALVES SHALL BE 2 | | | 1/2" TO 1 1/2" REDUCER WITH CHAINS. | | | | | | 29) MORE INFORMATION AND MANUFACTURER | | | SPEC SHEETS REQUIRED FOR FIRE PUMP AND | | | ASSOCIATED EQUIPMENT. | | | | | | 30) FIRE PROTECTION SHEETS DON'T SHOW | | | ANY FIRE SPRINKLER SYSTEM. ???? FIRE | | | SPRINKLER DESIGN AND LAY OUT MUST BE | | | ILLUSTRATED. | | | | | | 31) IF A FIRE HYDRANT FLOW TEST HASN'T | | | BEEN DONE WITHIN ONE YEAR, ANOTHER TEST | | | WILL BE REQUIRED FOR FIRE SPRINKLER | | | CALC. PLEASE CONTACT THE BUREAU OF FIRE | | | PREVENTION AT (561) 805-4724. | | | | | | 32) PLEASE INDICATE ALL SMOKE DETECTOR | | | LOCATIONS IN ACCORDANCE WITH NFPA 101, | | | SECTION 30.3.4.5. | | | | | | 33) EXIT LIGHTS TO BE MOUNTED AT | | | DISTANCES NOT TO EXCEED 100'. IT APPEARS | | | THAT MORE EXIT SIGNS ARE NEEDED IN | | | CORRIDORS. | | | | | | 34) FIRE ALARM SHALL BE CLASS A, STYLE D | | | OR FULLY ADDRESSABLE. | | | | | | 35) ARE SMOKE DETECTORS TIED INTO THE | | | FIRE ALARM SYSTEM PLANNED FOR CORRIDORS? | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
amckenzi |
Date |
2008-08-05 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
amckenzi |
Date |
2008-08-05 |
Time |
09:34 |
Sent To |
|
|
| Notes |
| 2008-08-05 09:35:45 | TO EXTEND APPLICATION UNTIL 11/5/08 PER NKM/AMM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-14 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-14 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2007-09-07 16:18:45 | TO "COMM" BD#55/PLANS ON RACK--15 ROLLS | | 2007-08-14 14:29:20 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2006-11-29 |
Time |
19:33 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2006-11-29 |
Time |
19:33 |
Sent To |
|
|
| Notes |
| 2006-12-08 15:30:12 | TO "COMM" BD#41--3 APPL. PLANS ON RACK--7 ROLLS | | 2006-11-29 19:33:34 | WAITING FOR "COMM" BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-11 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-11 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2006-09-11 00:00:00 | TO "COMM" BD#51/PLANS ON RACK-7 ROLLS | | | AND PAPERWORK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-31 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-31 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2006-08-31 00:00:00 | WAITING FOR "COMM" BD-ROLLS BY MIRELLE'S | | | CUBE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-03-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-12 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2005-10-12 00:00:00 | TO "COMM" BD#49/PLANS ON RACK | | 2005-10-03 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-10-30 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-10-30 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2007-10-30 15:27:09 | REVIEW #: 3 | | | ACTION: DENIED | | | | | | FBC 2001 CODES W/ 2003 REVISIONS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. OK | | | | | | 2. RETURN AIR TRANSFERS AND JUMPERS ARE STILL NOT | | | DESIGNED TO MEET THE EXCEPTIONS AS LISTED UNDER FBC,M | | | 601.4. EXAMPLE: UNIT B2 SHOWS AN 8 INCH ROUND (50 | | | SQ.IN) R/A JUMPER FOR 7 INCH (38.5 SQ.IN) AND 4 INCH | | | (13 SQ.IN) ROUND SUPPLY DROPS IN MASTER BEDROOM. THE | | | R/A JUMPER MUST BE 1.5 TIMES THE SIZE OF THE SUPPLY | | | DROPS IN THE MASTER TO MEET EXCEPTION 1 UNDER FBC,M | | | 601.4. THE 7IN PLUST THE 4IN DUCTS TOTAL 51.5 SQ. IN. | | | THE TRANSFER IS SMALLER THAN THE TWO SUPPLY DUCTS | | | RATHER THAN 1.5 TIMES LARGER. THE EXCEPTION HAS NOT | | | BEEN MET. IF THE DESIGNER CHOOSES NOT TO DESIGN TO MEET | | | THE EXCEPTIONS, A FIELD TEST WILL BE REQUIRED AT FINAL | | | INSPECTION TO DEMONSTRATE A MAX. PRESSURE DIFFERENTIAL | | | OF 0.01IN. W.C. ACROSS THE CLOSED BEDROOM DOORS AS | | | REQUIRED BY FBC,M 601.4. | | | | | | 3. OK | | | | | | 4. OK | | | | | | 5. M15.06: CONDENSATE TRAP DETAIL FOR NON-DUCTED RETURN | | | UNITS, THE SECONDARY DRAIN LINE FROM THE AUXILIARY | | | DRAIN PAN SHALL NOT BE CONNECTED TO THE PRIMARY | | | CONDENSATE RISER. A SEPARATE DRAIN LINE SHALL EXTEND | | | FROM THE PAN TO A CONSPICUOUS POINT AND SERVE AS AN | | | ALARM WHICH INDICATES THAT THE PRIMARY DRAIN IS | | | RESTRICTED.AS AN ALTERNATIVE TO A SEPARATE DRAIN | | | LINE, AN APPROVED WATER LEVEL DETECTOR OR FLOAT SWITCH | | | DEVICE SHALL BE USED TO CONTROL OVERFLOW BY | | | AUTOMATICALLY SHUTTING DOWN THE EQUIPMENT OR APPLIANCE | | | THAT PRODUCES THE CONDENSATE. THE FLOAT SWITCH ON THE | | | SECONDARY DRAIN OUTLET AT THE AHU MAY BE INSTALLED | | | (ALTHOUGH IT'S NOT NECESSARY) BUT IT CAN NOT REPLACE | | | THE SEPARATE SECONDARY DRAIN LINE OR THE FLOAT SWITCH | | | REQUIRED ON THE AUXILIARY DRAIN PAN. THE FLOAT SWITCH | | | ON THE SECONDARY DRAIN OUTLET AT THE AHU IS ACCEPTABLE | | | AS OVERFLOW PROTECTION ONLY ON THE DUCTED RETURN UNITS | | | WHERE AN AUXILIARY DRAIN PAN CAN NOT BE INSTALLED UNDER | | | THE AHU. FBC,M 307.2.3 AND 307.2.4 | | | | | | 6 THROUGH 10: OK | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-12-21 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-12-21 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2006-12-21 11:32:34 | DENIED:BUILDING #3 / 2001 FBC | | | | | | RESPONSE COMMENTS FROM REVIEW DATED 1-31-06: | | | | | | COMMENT #1: OK | | | | | | COMMENT #2: RESPONSE INDICATES NOTE FOR RETURN AIR | | | ON SHEETS M15.01 THROUGH M15.03.PLEASE NOTE, THE R/A | | | INDICATED ON THE PLAN IS CONSIDERED A TRANSFER UNDER | | | 2001 FMC 601.4 EXCEPTION 2 NOT 1.PLEASE VERIFY GRILLE | | | SIZE INTO THE MASTER SUITE.ALL AIR INTO THE MATER | | | SUITE IS TO BE INCLUDED IN THE CALCULATION (I.E., | | | BATHROOM, CLOSET, ETC.)PLEASE ALSO NOTE WALL CAVITIES | | | USED FOR TRANSPORTING R/A SHALL BE LINED WITH AN AIR | | | BARRIER & SEALED IN ACCORDANCE WITH 2001 FBC CHAPTER 13 | | | SUB-CHAPTER 410.1.ABCD.3.7. | | | | | | COMMENT #3:RESPONSE INDICATES AHU CLOSET DOOR IS | | | NON-COMBUSTIBLE BUT THE DOOR SCHEDULE ON SHEET A9.02 | | | STILL INDICATES A WOOD DOOR.PLEASE CLARIFY. | | | | | | COMMENT #4:RESPONSE STATES THE CLEARANCE AROUND THE | | | AHU EXCEEDS THE 4" REQUIREMENT UNDER 2001 FMC | | | 603.1.3.4.THE DETAIL ON PLAN SHEET M15.09 DOES NOT | | | REFLECT OR ANNOTATE A 4" CLEARANCE.PLEASE ALSO NOTE, | | | THE CONDENSATE LINE SHALL BE OF NON-COMBUSTIBLE | | | MATERIAL (NO PVC IN AHU CLOSET). | | | | | | COMMENT #5:RESPONSE REFERS TO "CONDENSATE TRAP | | | DETAIL" ON SHEET M15.09.PER 2001 FMC 307.2.3 & | | | 307.2.4 AN AUXILIARY DRAIN PAN IS REQUIRED.PLEASE | | | CONTACT HAROLD MOSER, CHIEF MECHANICAL INSPECTOR WITH | | | REGARDS TO INSTALLATION OF FLOAT SWITCH IN THE | | | AUXILIARY DRAIN OUTLET (TRAP).HAROLD MOSER MAY BE | | | CONTACTED AT (561)805-6732. | | | | | | COMMENT #6:OK | | | | | | COMMENT #7:OK | | | | | | COMMENT #8:OK | | | | | | COMMENT #9:OK | | | | | | COMMENT #10: OK | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT PATTY KRAUSS | | | AT (561)805-6719 OR E-MAIL AT [email protected]. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-31 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-31 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2006-01-31 00:00:00 | DENIED:2001 FLORIDA BUILDING CODE | | | | | | 1.PLAN SHEET AP A6.01 THROUGH A701, IT | | | APPEARS THE COORIDORS HAVE OPENINGS AT | | | CERTAIN POINTS.PLEASE INDICATE TOTAL | | | SQUARE FOOTAGE AS REQUIRED FOR 'NATURAL | | | VENTILATION'.THE OUTSIDE AIR | | | CALCULATIONS INDICATED ON PLAN SHEET | | | M15.13 DO NOT SHOW TOTAL SQUARE FOOTAGE. | | | | | | 2.PLANS INDICATE RETURN AIR JUMPERS | | | FROM THE BEDROOM AREAS.PLEASE NOTE, | | | THE RETURN AIR JUMPERS ARE TO BE SIZED | | | IN ACCORDANCE WITH 2001 FMC 601.4 | | | EXCEPTION 1 & 3.PLEASE REVISE RETURN | | | TO INCREASE TO THE REQUIRED MINIMUM. | | | | | | 3.PLANS INDICATE LOUVERED DOOR.THE | | | DOOR SCHEDULE INDICATES THIS AS BEING A | | | WOOD DOOR.THE AHU CLOSET IS CONSIDERED | | | A RETURN AIR PLENUM.THE DOOR MUST ALSO | | | MEET THE REQUIREMENT OF NON-COMBUSTIBLE | | | OR SHALL HAVE A FLAME SPREAD INDEX OF | | | NOT MORE THAN 25 AND A SMIKE DEVELOPED | | | INDEX OF NOT MORE THAN 50 WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 84.PLEASE | | | PROVIDE DOCUMENTATION ON THE DOORS. | | | | | | 4.PLEASE NOTE, PER 2001 FMC 603.1.3 4" | | | CLEARANCE AROUND THE AIR HANDLER IS | | | REQUIRED. | | | | | | 5.PLAN SHEET M15.12 DETAILS FOR THE | | | AHUDOES NOT INDICATE AN AUXILIARY | | | DRAIN PAN WITH OVERFLOW PROTECTION AS | | | REQUIRED BY 2001 FMC 307.2.3.PLEASE | | | REVISE. | | | | | | 6.CONDENSING UNIT STANDS SHALL COMPLY | | | WITH 2001 FBC 1511.7 FOR HEIGHT | | | REQUIREMENT ABOVE FINISHED ROOF. | | | | | | 7.CONDENSING UNIT STANDS SHALL COMPLY | | | WITH 2001 FMC 301.13 & CHAPTER 15 OF THE | | | FBC FOR WIND PRESSURES. | | | | | | 8.PLEASE PROVIDE LINE SIZES FOR THE | | | REFRIGERANT LINES AS WELL AS THE | | | CONDENSATE. | | | | | | 9.PLEASE INDICATE TERMINATION OF THE | | | CONDENSATE. | | | | | | 10. PLEASE PROVIDE ENERGY AND MANUAL J | | | CALCULATIONS IN ACCORDANCE WITH 2001 FBC | | | CHAPTER 13. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-16 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-11-15 |
Time |
19:04 |
Sent To |
|
|
| Notes |
| 2007-11-16 09:16:46 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW. THE COMMENT NUMBER | | | SHALL STAY THE SAME AS THE FIRST REVIEW: | | | | | | ******FROM PREVIOUS REVIEWS: 3RD REVIEW****** | | | | | | A. OK | | | B. OK | | | 1. OK | | | 2. OK | | | | | | 3. SHT AP/A5.12 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW SF DRAINED FOR EACH | | | AREA ALONG WITH 1/2 AREA OF ALL VERTICAL | | | WALLS, INCLUDING PARAPETS, AND THE AREA | | | OF ANY ROOFS THAT DRAIN ONTO THE ROOF | | | AREAS FROM ABOVE. - SHOW THE LOCATION OF | | | ALL SECONDARY ROOF DRAINS OR SCUPPERS. | | | IF SCUPPERS ARE USED, SUBMIT A DETAIL | | | SHOWING HEIGHT, WIDTH, AND DISTANCE TO | | | FLOW LINE OFF THE ROOF. SECTION 1503.4.2 ****RESPONSE | | | NOTED, BUT SHEETS A5.05, | | | A5.13, A5.25 WERE NOT SUBMITTED, AND NO CALCULATIONS | | | WITH INFORMATION REQUESTED | | | HAS BEEN LOCATED. | | | ******RESONSE NOTED, BUT THE SECONDARY ROOF DRAINAGE | | | HAS NOT BEEN PROPERLY ADDRESSED. WHEN THE DOWNSPOUT HAS | | | A BLOCKAGE, AND WHILE IT IS TRUE THAT THE STORM WATER | | | CAN DRAIN OVER THE TOP OF THE COLLECTOR HEAD, THE | | | CONCERN IS THAT WHEN THE SCUPPER OPENING IS BLOCKED | | | THEN NEITHER THE PRIMARY NOR THE SECONDARY ROOF DRAIN | | | WILL BE ABLE TO WORK. SECTION 1107.2 SEPARATE SYSTEMS | | | ARE REQUIRED AND THE OVERFLOW SCUPPER SHALL BE SIZED | | | PER SECTION 1107.3. | | | | | | 4. SHTS AP/A5.61 & AP/A5.62 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED IN FHA DESIGN | | | MANUAL PAGES 7.34 & 7.35. - LAVS SHALL | | | BE A MINIMUM OF 2' OFF THE WALL IN ORDER | | | TO BE CENTERED ON THE 48" LENGTH OF THE | | | CLEAR FLOOR SPACE. PLEASE INDICATE ON | | | PLANS. FHA DESIGN MANUAL PAGES 7.47 AND | | | 7.48. - WATER CLOSET OPENING SHALL BE A | | | MINIMUM OF 33" WITH THE WATER CLOSET 18" | | | OFF ONE FIXTURE AND 15" OFF THE OTHER | | | FIXTURE TO THE CENTER OF THE W/C. FHA | | | DESIGN MANUAL PAGES 7.43, 7.44, & 7.45. ****RESPONSE | | | NOTED, BUT SPECIFICATION | | | "A" OR "B" HAS NOT BEEN INDICATED. ALSO | | | THE WATER CLOSET OPENING MEASUREMENTS | | | HAS NOT BEEN SHOWN ON THE FLOOR PLAN. ******RESPONSE | | | NOTED, BUT SPECIFICATION "A" OR "B" HAS NOT BEEN | | | INDICATED. | | | | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK N/A | | | 9. OK | | | 10. OK | | | 11. OK | | | 12. OK | | | 13. OK | | | | | | 14. AN RPZV BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THE BUILDING. SECTION | | | 608.13.2. | | | ****RESPONSE NOTED, BUT COMMENT NOT | | | ADDRESSED. EACH BUILDING IS REQUIRED TO | | | HAVE ITS OWN RPZV BACKFLOW. INDICATE ON | | | PLANS AT THE WATER SERVICE TO THE | | | BUILDING. | | | ******RESPONSE NOTED, BUT THERPZV BACKFLOW FOR THIS | | | BUILDING IS NOT INDICATED ON SHEET 10 OF THE CIVIL | | | PLANS. | | | | | | 15. SUBMIT A WATER LAYOUT FOR BUILDING | | | AND WATER RISER DIAGRAMS. SHOW ALL PIPE | | | SIZES, VALVES, WATER HAMMER ARRESTORS, | | | (INSTALLED IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING). SECTIONS 104.3.1.1, | | | 606.1, 606.2, 608.13.2 & PDI-WH 201. | | | ****RESPONSE NOTED, BUT THE WATER RISER | | | DIAGRAM SHALL BE SUBMITTED IN ISOMETRIC | | | FORM. WATER HAMMER ARRESTORS AND | | | REQUIRED VALVES CAN NOT BE SHOWN ON A | | | FLAT PIPING LAYOUT. | | | ******RESPONSE NOTED, BUT THIS IS UNIT ISOMETRIC RISER | | | DIAGRAMS ONLY. PLEASE SUBMIT THE WATER MAIN PIPING FROM | | | THE ENTRANCE OF THE BUILDING, ALL HORIZONTAL MAINS, ALL | | | RISERS THRU THE 5TH FLOOR. (ALL PIPING OTHER THAT UNIT | | | RISER DIAGRAMS IN ISOMETRIC RISER DIAGRAM FORM). | | | | | | 16. SUBMIT A BUILDING SANITARY DRAIN | | | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, TRAPS, OFFSETS, RISER LOCATIONS | | | WITH RISER NUMBERS, DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM ETC. SECTION | | | 104.3.1.1. | | | ***COMMENT RESPONSE NOTED, BUT COMMENT | | | NOT ADDRESSED. | | | ******RESPONSE NOTED, BUT THE RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN WHERE THE LAST TWO BRANCH LINES | | | CONNECT TO THE BUILDING DRAIN, AT THE FLOOR DRAIN, AND | | | THE RISER PRIOR TO THE FLOOR DRAIN. ALSO THE FLOOR | | | DRAIN IS NOT VENTED AS PIPED ON THE FLOOR PLAN.-- | | | SHOW CLEANOUTS REQUIRED BY SECTION 708.3.3 ON THE RISER | | | DIAGRAM AND THE FLOOR PLAN.--NO RISER DESIGNATION | | | NUMBERS WERE GIVEN FOR THE RISERS. THIS IS REQUIRED TO | | | TRACK THE RISERS FROM THE BUILDING DRAIN THRU THE 5TH | | | FLOOR. | | | | | | 17. SUBMIT A BUILDING STORM DRAIN | | | ISOMETRIC RISER DIAGRAM, SHOWING ALL | | | PIPE SIZES, RISER LOCATIONS WITH RISER | | | NUMBERS, AND SQUARE FEET AS IT | | | ACCUMULATES IN THE SYSTEM. SECTION | | | 104.3.1.1. | | | ****RESPONSE NOTED, BUT NOT ADDRESSED. ******RESPONSE | | | NOTED, BUT THE STORM ISOMETRIC RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN. SOME PIPE SIZES ARE DIFFERENT, | | | CLEANOUTS, ETC.--P-TRAPS ARE NOT REQUIRED IN THE | | | STORM PIPING SYSTEM.--SHOW ALL CLEANOUTS REQUIRED | | | BY SECTION 1101.8. | | | | | | 18. OK | | | | | | **************NEW COMMENTS************** | | | | | | 1B. ALL ARCHITECTURAL SHEETS. THE TITLE | | | BLOCK SHALL CONTAIN THE PRINTED NAME OF | | | THE PERSON SEALING THE DOCUMENT. FAC 61G1-16.004(6) & | | | FS F81.2055. | | | ******RESPONSE NOTED, BUT SHT GN/A1.04 IS STILL MISSING | | | THE PRINTED NAME. | | | | | | 2B. SHT AP P14.04 PIPING FOR THE | | | FIXTURES ON THE SECOND THRU 4TH FLOORS | | | SHALL BE SHOWN ON THE FLOOR PLAN WITH | | | THE FIXTURES, (SHT P14.05). SECTION | | | 104.2.1.3. | | | ******RESPONSE NOTED, BUT MANY RISER NUMBERS ARE NOT | | | SHOWN AS WELL AS THE PIPING IN ABOUT 6 OR 7 UNITS IS | | | NOT SHOWN. | | | | | | 3B. OK | | | | | | 4B. SUBMIT A DETAIL FOR THE DOWNSPOUTS | | | AND THE COLLECTOR HEAD AT THE TOP. | | | INDICATE SIZE OF DOWNSPOUT, LENGTH, | | | WIDTH & HEIGHT OF COLLECTOR HEAD. | | | INDICATE ON ROOF PLAN SQUARE FOOTAGE | | | DRAINING INTO EACH DOWNSPOUT. | | | ******RESPONSE NOTED, BUT THE DETAIL DOES NOT SHOW | | | LENGHT, WIDTH OR HEIGHT. SUBMIT AN ELEVATION DETAIL | | | SHOWING THESE MEASUREMENTS AS WELL AS A CUT SECTION. | | | SECTION 1106.3. | | | | | | 5B. SECONDARY DRAINAGE AND SEPARATE | | | SYSTEMS ARE REQUIRED FOR THE ROOF | | | DRAINAGE PER SECTIONS 1107.1 & 1107.2. | | | PLEASE INDICATE THE LOCATION AND SIZE OF | | | THE SECONDARY ROOF DRAINAGE. SUBMIT A | | | DETAIL FOR THE SECONDARY ROOF DRAINS. ******RESPONSE | | | NOTED, BUT THE INTENT OF THE CODE SECTION HAS NOT BEEN | | | ADDRESSED. WHEN THE DOWNSPOUT HAS A BLOCKAGE, AND WHILE | | | IT IS TRUE THAT THE STORM WATER CAN DRAIN OVER THE TOP | | | OF THE COLLECTOR HEAD, THE CONCERN IS THAT WHEN THE | | | SCUPPER OPENING IS BLOCKED THEN NEITHER THE PRIMARY NOR | | | THE SECONDARY ROOF DRAIN WILL BE ABLE TO WORK. SECTION | | | 1107.2 SEPARATE SYSTEMS ARE REQUIRED AND THE OVERFLOW | | | SCUPPER SHALL BE SIZED PER SECTION 1107.3. SHOW THE | | | LOCATION OF THE EMERGENCY OVERFLOW SCUPPERS. | | | | | | 6B. OK | | | | | | ********NEW COMMENTS 3RD REVIEW******** | | | | | | 1C. THE STRUCTURAL SHEETS ONE SET HAVE NOT BEEN SIGNED, | | | SEALED & DATED. FAC 61G15-23.002(1) & FS 471.025. | | | | | | 2C. SOME ARCHITECTURAL SHEETS IN ONE SET HAVE NOT BEEN | | | SIGNED, SEALED & DATED. FAC 61G1-16.003, FAC | | | 61G1-16.004(5) & FS 481.2055. | | | | | | 3C. SHT AP/P14.01 AND OTHER PLUMBING SHEETS REVISION 1 | | | HAS BEEN DELETED FROM THE TITLE BLOCK REVISION INDEX. | | | PLEASE SHOW THE COMPLETE HISTORY OF REVISIONS ON THE | | | REVISION INDEX FOR ACCURATE RECORD KEEPING. SECTION | | | 104.2.1.3. | | | | | | 4C. SHT AP/P14.03 THE FLOOR DRAIN IN THE PUMP ROOM CAN | | | NOT DRAIN TO STORM. ARTICLE III SECTION 90-203 CITY WPB | | | MUNICIPAL CODE. CONNECT ALL FLOOR DRAINS TO THE | | | SANITARY SYSTEM. | | | | | | 5C. SHT AP/P14.08 STORM ISOMETRIC RISER DIAGRAM DOES | | | NOT REFLECT THE FLOOR PLAN. SOME PIPE SIZES ARE | | | DIFFERENT, CLEANOUTS, ETC.--P-TRAPS ARE NOT | | | REQUIRED IN THE STORM PIPING SYSTEM.--SHOW ALL | | | CLEANOUTS REQUIRED BY SECTION 1101.8. | | | | | | 6C. SHT AP/P14.10 WATER HEATER DETAIL. A FULL OPEN | | | VALVE IS REQUIRED ON THE SUPPLY LINE TO THE WATER | | | HEATER. SECTION 606.1(7). PLEASE SHOW ON DETAIL.-- | | | SANITARY RISER #7 HAS 24 DFU'S, NOT 20 AS INDICATED. | | | TABLE 709.1. PLEASE CORRECT DFU'S. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6713 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-11 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-11 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2006-10-11 10:03:16 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW. THE COMMENT NUMBER | | | SHALL STAY THE SAME AS THE FIRST REVIEW: | | | | | | A. OK | | | B. OK | | | 1. OK | | | 2. OK | | | | | | 3. SHT AP/A5.12 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW SF DRAINED FOR EACH | | | AREA ALONG WITH 1/2 AREA OF ALL VERTICAL | | | WALLS, INCLUDING PARAPETS, AND THE AREA | | | OF ANY ROOFS THAT DRAIN ONTO THE ROOF | | | AREAS FROM ABOVE. - SHOW THE LOCATION OF | | | ALL SECONDARY ROOF DRAINS OR SCUPPERS. | | | IF SCUPPERS ARE USED, SUBMIT A DETAIL | | | SHOWING HEIGHT, WIDTH, AND DISTANCE TO | | | FLOW LINE OFF THE ROOF. SECTION 1503.4.2 ****RESPONSE | | | NOTED, BUT SHEETS A5.05, | | | A5.13, A5.25 WERE NOT SUBMITTED, AND NO CALCULATIONS | | | WITH INFORMATION REQUESTED | | | HAS BEEN LOCATED. | | | | | | 4. SHTS AP/A5.61 & AP/A5.62 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED IN FHA DESIGN | | | MANUAL PAGES 7.34 & 7.35. - LAVS SHALL | | | BE A MINIMUM OF 2' OFF THE WALL IN ORDER | | | TO BE CENTERED ON THE 48" LENGTH OF THE | | | CLEAR FLOOR SPACE. PLEASE INDICATE ON | | | PLANS. FHA DESIGN MANUAL PAGES 7.47 AND | | | 7.48. - WATER CLOSET OPENING SHALL BE A | | | MINIMUM OF 33" WITH THE WATER CLOSET 18" | | | OFF ONE FIXTURE AND 15" OFF THE OTHER | | | FIXTURE TO THE CENTER OF THE W/C. FHA | | | DESIGN MANUAL PAGES 7.43, 7.44, & 7.45. ****RESPONSE | | | NOTED, BUT SPECIFICATION | | | "A" OR "B" HAS NOT BEEN INDICATED. ALSO | | | THE WATER CLOSET OPENING MEASUREMENTS | | | HAS NOT BEEN SHOWN ON THE FLOOR PLAN. | | | | | | 5. SHT AP/A5.56 INDICATE MATERIAL FOR | | | GRAB BAR BLOCKING. SECTION 104.2.1. | | | ***RESPONSE NOTED, (SEE AP A5.56), BUT | | | SHT AP/A5.56 HAS NOT BEEN SUBMITTED. | | | PLEASE CLARIFY. | | | | | | 6. OK | | | 7. OK | | | | | | 8. SUBMIT A DETAIL FOR THE COMMON USE | | | TOILET ROOMS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.16, 11-4.19, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | ****RESPONSE NOTED, (SEE SHEET A5.70 AND | | | A5.71), BUT THOSE SHEETS HAVE NOT BEEN | | | SUBMITTED. | | | | | | 9. SHTS AP/P14.02 UNITS B3 & B4 MAXIMUM | | | 4 FU ON A 2" WET VENT IN MASTER BATH. | | | TABLE 909.3. | | | ****RESPONSE NOTED, BUT NOT THE RISER | | | DIAGRAM DOES NOT REFLECT THE FLOOR PLAN | | | AS THE FLOOR PLAN SHOWS 3" AND THE RISER | | | DIAGRAM SHOWS 2-1/2" FOR THE WET VENT. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. | | | | | | 10. OK | | | | | | 11. SHT AP/P14.26 OFFSETS IN THE SANT. | | | SHALL BE SHOWN ON EITHER BLDG. DRAIN | | | ISOMETRIC RISER DIAGRAM, OR SANT. RISER | | | DIAGRAMS. SECTION 104.2.1. | | | ****RESPONSE NOTED, BUT WHEN THE SANT. | | | RISER FROM UNDERGROUND IS ABOVE THE | | | CEILING OF THE FIRST FLOOR, THE RISER | | | SPLITS AND OFFSETS INTO OTHER RISERS. | | | (EXAMPLE RISER 2,3,6 COMES OUT OF THE | | | GROUND AND OFFSETS ABOVE THE CEILING AND | | | SPLITS INTO THREE SEPARATE RISERS. | | | BUILDING DRAIN ISOMETRIC RISER SHALL | | | REFLECT THIS PIPING. SECTION 104.3.1.1. | | | | | | 12. OK | | | 13. OK | | | | | | 14. AN RPZV BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THE BUILDING. SECTION | | | 608.13.2. | | | ****RESPONSE NOTED, BUT COMMENT NOT | | | ADDRESSED. EACH BUILDING IS REQUIRED TO | | | HAVE ITS OWN RPZV BACKFLOW. INDICATE ON | | | PLANS AT THE WATER SERVICE TO THE | | | BUILDING. | | | | | | 15. SUBMIT A WATER LAYOUT FOR BUILDING | | | AND WATER RISER DIAGRAMS. SHOW ALL PIPE | | | SIZES, VALVES, WATER HAMMER ARRESTORS, | | | (INSTALLED IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING). SECTIONS 104.3.1.1, | | | 606.1, 606.2, 608.13.2 & PDI-WH 201. | | | ****RESPONSE NOTED, BUT THE WATER RISER | | | DIAGRAM SHALL BE SUBMITTED IN ISOMETRIC | | | FORM. WATER HAMMER ARRESTORS AND | | | REQUIRED VALVES CAN NOT BE SHOWN ON A | | | FLAT PIPING LAYOUT. | | | | | | 16. SUBMIT A BUILDING SANITARY DRAIN | | | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, TRAPS, OFFSETS, RISER LOCATIONS | | | WITH RISER NUMBERS, DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM ETC. SECTION | | | 104.3.1.1. | | | ***COMMENT RESPONSE NOTED, BUT COMMENT | | | NOT ADDRESSED. | | | | | | 17. SUBMIT A BUILDING STORM DRAIN | | | ISOMETRIC RISER DIAGRAM, SHOWING ALL | | | PIPE SIZES, RISER LOCATIONS WITH RISER | | | NUMBERS, AND SQUARE FEET AS IT | | | ACCUMULATES IN THE SYSTEM. SECTION | | | 104.3.1.1. | | | ****RESPONSE NOTED, BUT NOT ADDRESSED. | | | SEE COMMENT RESPONSE TO COMMENT #10. | | | | | | 18. OK | | | | | | **************NEW COMMENTS************** | | | | | | 1B. ALL ARCHITECTURAL SHEETS. THE TITLE | | | BLOCK SHALL CONTAIN THE PRINTED NAME OF | | | THE PERSON SEALING THE DOCUMENT. FAC 61G1-16.004(6) & | | | FS F81.2055. | | | | | | 2B. SHT AP P14.04 PIPING FOR THE | | | FIXTURES ON THE SECOND THRU 4TH FLOORS | | | SHALL BE SHOWN ON THE FLOOR PLAN WITH | | | THE FIXTURES, (SHT P14.05). SECTION | | | 104.2.1.3. | | | | | | 3B. SHTS AP A5.60, AP A5.61, AP A5.62 | | | REFER TO SHEET A5.58. THIS SHEET HAS NOT | | | BEEN SUBMITTED. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | 4B. SUBMIT A DETAIL FOR THE DOWNSPOUTS | | | AND THE COLLECTOR HEAD AT THE TOP. | | | INDICATE SIZE OF DOWNSPOUT, LENGTH, | | | WIDTH & HEIGHT OF COLLECTOR HEAD. | | | INDICATE ON ROOF PLAN SQUARE FOOTAGE | | | DRAINING INTO EACH DOWNSPOUT. | | | | | | 5B. SECONDARY DRAINAGE AND SEPARATE | | | SYSTEMS ARE REQUIRED FOR THE ROOF | | | DRAINAGE PER SECTIONS 1107.1 & 1107.2. | | | PLEASE INDICATE THE LOCATION AND SIZE OF | | | THE SECONDARY ROOF DRAINAGE. SUBMIT A | | | DETAIL FOR THE SECONDARY ROOF DRAINS. | | | | | | 6B. SHT AP A5.32 ROOF PLAN SHOWS UNITS | | | AND FIXTURES. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6713 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-01-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-01-18 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-01-18 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2006-01-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A. PLANS WERE SUBMITTED AS LOOSE SHEETS | | | AND AS SUCH IS NOT ACCEPTABLE. PLEASE | | | SUBMIT PLANS IN BOUND SETS. SECTION | | | 104.2.1.3. | | | B. PERMITS INDICATE 3 SEPARATE | | | BUILDINGS, BUT PLANS INDICATE ONE | | | BUILDING. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | 1. ALL ARCHITECTURAL SHEETS, (EXCEPT FOR | | | STRUCTURAL), ARE NOT SEALED AS REQUIRED | | | IN SECTION 104.2.2 & FAC 61G1-16.003 | | | 61G1-16.004(5) & FS 481.2055. | | | 2. SHTS AP/A1.02 & AP/A1.03 SHOWN IN | | | DRAWING INDEX ON SHT AP/A1.01 HAVE NOT | | | BEEN SUBMITTED. SECTION 104.2.1. | | | 3. SHTS AP/A5.24 & AP/A5.25 SUBMIT | | | CALCULATIONS FOR PRIMARY AND SECONDARY | | | ROOF DRAINS PER SECTIONS 1106 & 1107 AND | | | ALL SUBSECTIONS. SHOW SF DRAINED FOR | | | EACH AREA ALONG WITH 1/2 AREA OF ALL | | | VERTICAL WALLS, INCLUDING PARAPETS, AND | | | THE AREA OF ANY ROOFS THAT DRAIN ONTO | | | THE ROOF AREAS FROM ABOVE. - SHOW THE | | | LOCATION OF ALL SECONDARY ROOF DRAINS OR | | | SCUPPERS. IF SCUPPERS ARE USED, SUBMIT A | | | DETAIL SHOWING HEIGHT, WIDTH, AND | | | DISTANCE TO FLOW LINE OFF THE ROOF. | | | SECTION 1503.4.2 | | | 4. SHTS AP/A5.61 & AP/A5.62 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED IN FHA DESIGN | | | MANUAL PAGES 7.34 & 7.35. - LAVS SHALL | | | BE A MINIMUM OF 2' OFF THE WALL IN ORDER | | | TO BE CENTERED ON THE 48" LENGTH OF THE | | | CLEAR FLOOR SPACE. PLEASE INDICATE ON | | | PLANS. FHA DESIGN MANUAL PAGES 7.47 AND | | | 7.48. - WATER CLOSET OPENING SHALL BE A | | | MINIMUM OF 33" WITH THE WATER CLOSET 18" | | | OFF ONE FIXTURE AND 15" OFF THE OTHER | | | FIXTURE TO THE CENTER OF THE W/C. FHA | | | DESIGN MANUAL PAGES 7.43, 7.44, & 7.45. | | | 5. SHT AP/A5.56 INDICATE MATERIAL FOR | | | GRAB BAR BLOCKING. SECTION 104.2.1. | | | 6. SHTS AP/A5.50 THRU AP/A5.55 LAV SHALL | | | BE 34" TO TOP OF FIXTURE RIM, NOT 36" AS | | | SHOWN. FHA DESIGN MANUAL PAGE 7.52. | | | 7. SHTS AP/A6.01 THRU AP/A6.04 INDICATE | | | THE BLDG. NUMBERS FOR EACH OF THE | | | BUILDING ELEVATIONS. | | | 8. SUBMIT A DETAIL FOR THE COMMON USE | | | TOILET ROOMS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.16, 11-4.19, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | 9. SHTS AP/P14.02 UNITS B3 & B4 MAXIMUM | | | 4 FU ON A 2" WET VENT IN MASTER BATH. | | | TABLE 909.3 | | | 10. SHT AP/P14.05 VENTS ARE REQUIRED FOR | | | THE FLOOR DRAINS. SECTION 901.2.1. - | | | CLEANOUTS ARE REQUIRED IN THE SANT. | | | BUILDING DRAIN AT ALL CHANGES OF | | | DIRECTION OVER 45 DEGREES. SECTION | | | 708.3.3. | | | 11. SHT AP/P14.26 OFFSETS IN THE SANT. | | | SHALL BE SHOWN ON EITHER BLDG. DRAIN | | | ISOMETRIC RISER DIAGRAM, OR SANT. RISER | | | DIAGRAMS. SECTION 104.2.1. | | | 12. SHT AP/P14.27 SANT. RISER S/9, | | | PLEASE INDICATE FIXTURE TYPE FOR FIXTURE | | | L-3. THIS IS NOT SHOWN ON PLUMBING | | | FIXTURE SCHEDULE. SECTION 104.2.1. | | | 13. SHT AP/P14.27 WATER HEATER PIPING | | | DETAIL, THERMAL EXPANSION CONTROL IS | | | REQUIRED PER SECTION 607.3.2. PLEASE | | | INDICATE METHOD. - DIELECTRIC UNIONS ARE | | | NOT APPROVED FOR WATER SUPPLY. | | | DIELECTRIC COUPLING TO BE USED. | | | 14. AN RPZV BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THE BUILDING. SECTION | | | 608.13.2. | | | 15. SUBMIT A WATER LAYOUT FOR BUILDING | | | AND WATER RISER DIAGRAMS. SHOW ALL PIPE | | | SIZES, VALVES, WATER HAMMER ARRESTORS, | | | (INSTALLED IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING). SECTIONS 104.3.1.1, | | | 606.1, 606.2, 608.13.2 & PDI-WH 201. | | | 16. SUBMIT A BUILDING SANITARY DRAIN | | | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, TRAPS, OFFSETS, RISER LOCATIONS | | | WITH RISER NUMBERS, DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM ETC. SECTION | | | 104.3.1.1. | | | 17. SUBMIT A BUILDING STORM DRAIN | | | ISOMETRIC RISER DIAGRAM, SHOWING ALL | | | PIPE SIZES, RISER LOCATIONS WITH RISER | | | NUMBERS, AND SQUARE FEET AS IT | | | ACCUMULATES IN THE SYSTEM. SECTION | | | 104.3.1.1. | | | 18. SUBMIT STORM RISER DIAGRAMS SHOWING | | | ALL PIPE SIZES, OFFSETS, AND SQUARE | | | FOOTAGE DRAINED FOR EACH RISER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
X |
PERMIT EXTENSION |
| Rev No |
1 |
Status |
N |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
dfulcher |
Date |
2008-11-05 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
dfulcher |
Date |
2008-11-05 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2008-11-05 09:28:26 | EXTEND APP TO 2/3/09 PER RAB |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-12-26 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-12-22 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-12-22 |
Time |
07:51 |
Sent To |
|
|
| Notes |
| 2006-12-26 07:51:29 | PLANNING AND ZONING**** FAILED **** | | | | | | | | | 1.PROVIDE RESPONSES TO COMMENTS IN WRITING AND | | | INDICATE THE REVISIONS ON SITE PLAN. | | | | | | 2.A MINOR AMENDMENT TO THE COURTNEY LAKES PB 1402 | | | PLANNED DEVELOPMENTIS REQUIRED TO REFLECT NUMBER OF | | | HANDICAP PARKING SPACES REQUIRED.AN APPLICATION WILL | | | NEED TO BE FILED TO THE PLANNING AND ZONING DEPARTMENT | | | AND APPROVED PRIOR TO SIGN-OFF OF BUILDING PERMIT. | | | | | | 3.PURSUANT TO SECTION 94-485(O)PAGE CD 94:273 OF THE | | | CODE, THE AMOUNT OF DISABLED PARKING SPACES PROPOSED | | | DOES NOT COMPLY.THERE ARE TWENTY (20) REQUIRED | | | PARKING SPACES THAT NEED TO BE PROVIDED.IN ADDITION, | | | THE LOCATION OF THE SPACES SHALL BE LOCATED SO THAT | | | USERS ARE NOT COMPELLED TO WALK OR OTHERWISE MOVE | | | BEHIND PARKED VEHICLES.WHY ARE THESE SPACES LOCATED | | | ACROSS DRIVE AISLES INSTEAD OF CLOSE PROXIMITY TO THE | | | BUILDING ACCESS? REVISE ACCORDINGLY. | | | | | | SHOULD YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1435 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-03-03 |
Time |
18:21 |
Rev Time |
|
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2006-03-03 00:00:00 | REVIEW DONE UNDER 05091684 |
|
|
|