Plan Review Details - Permit 05091684
| Plan Review Stops For Permit 05091684 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2007-09-24 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-09-24 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-09-24 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2007-09-24 09:52:08 | NEW SITE ADDRESS HAS BEEN ASSIGNED TO BUILDING 1( CLUB | | | HOUSE)AS 344 COURTNEY LAKES CIR , WEST PALM BEACH , | | | FL 33401 | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2007-02-09 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-02-09 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-02-09 |
Time |
13:22 |
Sent To |
|
|
| Notes |
| 2007-02-09 13:32:32 | BEFORE A SITE ADDRESS CAN BE ISSUED FOR THIS PROJECT | | | THE INTERIOR PRIVATE STREETS MUST BE NAMED FIRST. | | | PLEASE CONTACT ME FOR MORE INFORMATION . | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-01 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2006-03-01 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2006-03-01 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2006-03-01 00:00:00 | SITE PLAN NEEDED TO ASSIGN NEW | | | ADDRESSES;UNITY OF TITLE,PROPESED PLAT. | | 2005-12-26 00:00:00 | NEEDS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
jjohnsto |
Date |
2007-10-19 |
Time |
08:27 |
Rev Time |
24.00 |
| Received By |
jjohnsto |
Date |
2007-10-19 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2007-10-19 08:30:06 | CONSTRUCTION SERVICES DEPARTMENT | | | 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH, | | | FLORIDA33401 | | | TEL:561-805-6713FAX: | | | 561-805-6731 | | | | | | JAMES JOHNSTON, PERMIT NO 05091684 | | | BUILDING PLAN EXAMINERII PROJECT | | | NAME COURTNEY LAKES, BLDG. 1 | | | E-MAIL:JJOHNSTON @WPB.ORG ADDRESS | | | 344 COURTNEY LAKES CIRCLE | | | DATE OCTOBER 17, 2007 | | | | | | BUILDINGPLANREVIEW | | | FLORIDA BUILDING CODE 2001 | | | | | | | | | FOR YOUR INFORMATION?. | | | THE PLANS SUBMITTED ARE DRAWN FOR THIS PROJECT?S | | | BUILDINGS TO BE CONSTRUCTED IN PHASES.PLEASE SEE THE | | | 2001 CODE RELATED SECTION 104.5.1.104.5.1.1, | | | 104.5.1.2 -NOTED HEREIN -REFERCENING,?WORK NOT | | | COMMENCED WITHIN 6 MONTHS AFTER DATE OF PERMIT ISSUANCE | | | THE PERMIT SHALL BE REVOKED AND A NEW PERMIT SHALL BE | | | ISSUED.? THE NEW PERMIT SHALL BE ISSUED UNDER THE2004 | | | BUIDING CODENOT THE 2001, REQUIRING EXISTING PLANS TO | | | BE REDRAWN IN COMPLIANCE WITH THIS CODE. | | | | | | 104.5 CONDITIONS OF THE PERMIT | | | 104.5.1 PERMIT INTENT. A PERMIT ISSUED SHALL BE | | | CONSTRUED TO BE A LICENSE TO PROCEED WITH THE WORK AND | | | NOT AS AUTHORITY TO VIOLATE, CANCEL, ALTER, OR SET | | | ASIDE ANY OF THE PROVISIONS OF THE TECHNICAL CODES, NOR | | | SHALL ISSUANCE OF A PERMIT PREVENT THE BUILDING | | | OFFICIAL FROM THEREAFTER REQUIRING A CORRECTION OF | | | ERRORS IN PLANS, CONSTRUCTION, OR VIOLATIONS OF THIS | | | CODE. EVERY PERMIT ISSUED SHALL BECOME INVALID UNLESS | | | THE WORK AUTHORIZED BY SUCH PERMIT IS COMMENCED WITHIN | | | 6 MONTHS AFTER ITS ISSUANCE, OR IF THE WORK AUTHORIZED | | | BY SUCH PERMIT IS SUSPENDED OR ABANDONED FOR A PERIOD | | | OF 6 MONTHS AFTER THE TIME THE WORK IS COMMENCED. | | | | | | 104.5.1.1 IF WORK HAS COMMENCED AND THE PERMIT IS | | | REVOKED, BECOMES NULL AND VOID, OR EXPIRES BECAUSE OF | | | LACK OF PROGRESS OR ABANDONMENT, A NEW PERMIT COVERING | | | THE PROPOSED CONSTRUCTION SHALL BE OBTAINED BEFORE | | | PROCEEDING WITH THE WORK. | | | | | | 104.5.1.2 IF A NEW PERMIT IS NOT OBTAINED WITHIN 180 | | | DAYS FROM THE DATE THE INITIAL PERMIT BECAME NULL AND | | | VOID, THE BUILDING OFFICIAL IS AUTHORIZED TO REQUIRE | | | THAT ANY WORK WHICH HAS BEEN COMMENCED OR COMPLETED BE | | | REMOVED FROM THE BUILDING SITE. ALTERNATELY, A NEW | | | PERMIT MAY BE ISSUED ON APPLICATION, PROVIDING THE WORK | | | IN PLACE AND REQUIRED TO COMPLETE THE STRUCTURE MEETS | | | ALL APPLICABLE REGULATIONS IN EFFECT AT THE TIME THE | | | INITIAL PERMIT BECAME NULL AND VOID AND ANY REGULATIONS | | | WHICH MAY HAVE BECOME EFFECTIVE BETWEEN THE DATE OF | | | EXPIRATION AND THE DATE OF ISSUANCE OF THE NEW PERMIT. | | | | | | 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHEN APPROVED BY THE BUILDING | | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL (SEE ALSO SECTION 106.3.5 ). | | | COMMENT-SHEETSGN A1.05GN A1.06THESE SHEETS ARE | | | NOT LEGIBLE. | | | | | | | | | | | | A 1804.2.2 SOIL TEST REPORT | | | THE REPORT SUBMITTED IN 2003 REFERENCES A CONCLUSION OF | | | BEARING CAPACITY | | | FOR A SINGLE STORY STRUCTURE. WHERE THE BEARING | | | CAPACITY OF THE SOIL IS | | | NOT DEFINITELY KNOWN OR IS IN QUESTION, THE BUILDING | | | OFFICIAL MAY REQUIRE | | | LOAD TESTS OR OTHER ADEQUATE PROOF AS TO THE | | | PERMISSIBLE SAFE BEARING | | | CAPACITY AT THAT PARTICULAR LOCATION.TO DETERMINE THE | | | SAFE BEARING | | | CAPACITY OF SOIL, IT SHALL BE TESTED AT SUCH LOCATIONS | | | AND LEVELS AS | | | CONDITIONS WARRANT, BY LOADING AN AREA NOT LESS THAN 4 | | | SQ FT (0.37 M{2}) | | | TO NOT LESS THAN TWICE THE MAXIMUM BEARING CAPACITY | | | DESIRED FOR USE.SUCH | | | DOUBLE LOAD SHALL BE SUSTAINED BY THE SOIL FOR A PERIOD | | | OF NOT LESS THAN | | | 48 HOURS WITH NO ADDITIONAL SETTLEMENT TAKING PLACE, IN | | | ORDER THAT SUCH | | | DESIRED BEARING CAPACITY MAY BE USED.SUBSOIL | | | CONDITIONS SHALL BE | | | EXAMINED AT THE EXPENSE OF THE OWNER, WHEN DEEMED | | | NECESSARY BY THE | | | BUILDING OFFICIAL. | | | COMMENTPLEASE FURNISH A SOIL TEST REPORT APPLICABLE | | | FOR THE THREE BUILDINGS ?FIVE STORIES EACH TO BE | | | CONSTRUCTED WITH THE RECOMMENDATIONS FOR PROPER GROUND | | | PREPARATION TO ACHIEVE THE DESIRED BEARING CAPACITY | | | FOR EACH BUILDING. | | | TWO COPIES OF THIS REPORT SHALL BE INCLUDED FOR EACH | | | SEPARATE BUILDING PROJECT.THE REPORT IS TO ENCOMPASS | | | THE THREE BUILDINGS, TWO COPIES FOR EACH BUILDING | | | | | | A-1 FBC1816.1SOIL TREATMENT | | | COMMENTIDENTIFY THE CHEMICAL SOIL TREATMENT TO BE | | | USED IN THE SLAB NOTES SHEET APS3.21 | | | | | | | | | B PRODUCT APPROVALS | | | COMMENTTHE FLORIDA PRODUCT APPROVAL COVER SHEET | | | SHALL INCLUDE THE APPROVAL INFORMATION FOR THE PRODUCT | | | SELECTED.SEE ATTACHED SAMPLE INCLUDED. | | | THE DESIGNER OF RECORD SHALL REVIEW EACH APPROVAL?S | | | SPECIFICATION PACKETAND ACKNOWLEDGE SAME ON THE | | | APPROVAL COVER SHEETBY NAME DATE AND STATEMENT OF | | | ACCEPTANCE | | | | | | | | | B-1 WINDOWS / DOORS PRODUCT APPROVALS | | | WPB ADMINISTRATIVE CODE 106.3 REGULATED BY DCA RULE | | | 9B-72FLORIDA PRODUCT APPROVAL | | | SUBMIT TWO COPIES OF EACH APPROVAL WITH FLORIDA PRODUCT | | | APPROVAL COVER SHEET THE ARCHITECT?S / ENGINEER?S | | | SIGNATURE AS APPLICABLE, STATING ?TO THE BEST OF THEIR | | | KNOWLEDGE THE PRODUCT APPROVAL COMPLIES WITH THE PLANS | | | AND SPECIFICATIONS.SEE:WEB SITE | | | WWW.FLORIDABUILDING.COM | | | NOTE: SEE DIVISION FACTOR TO BE USED IN DESIGN PRESSURE | | | BY LEGACYFPA | | | COMMENT-FOR YOUR INFORMATION | | | | | | | | | B-2 SUBMIT PRODUCT APPROVALS WITH FLORIDA PRODUCT | | | APPROVAL COVER | | | PAGE FOR THE FOLLOWING | | | OPERABLE WINDOWS | | | FIXED GLASS | | | MULLION TUBES | | | PANEL WALLS | | | STORE FRONT GLAZING SYSTEM | | | ALUMINUM OUT -SWING DOORS | | | HOLLOW METAL DOORS | | | TRUSS ANCHORS | | | ROOFINGCOMPONENTS | | | SHUTTERS | | | SKYLIGHTS | | | OVERHEAD GARAGE DOOR | | | COMMENT-PLEASE COMPLY | | | | | | B-3 3RD REQUEST ? | | | COMMENT-FURNISH THE FOLLOWING PRODUCT REPORTS | | | TRACO OPERABLE WINDOWSNON IMPACT 0? TO 30?,LARGE | | | MISSILE 30? TO 60? | | | TRACO FIXED WINDOWS | | | MULLIONS | | | EXTERIOR HOLLOW METAL DOORS | | | EXTERIOR GLAZED DOORS | | | EXTERIOR LOUVER DOORS | | | EXTERIOR RAILINGS, ENGINEERING REQUIRED | | | LOUVERS,NO REPORT SUBMITTED | | | ROOF ASSEMBLIES, DENSE DECK, ATTACHMENTS, INSULATION, | | | UNDERLAYMENT,ROOF TILE,ROOF SYSTEM | | | IDENTIFY EACH COMPONENT TO BE USED | | | RATIONAL ANALYSIS FOR ZONE 2 AND THREE | | | EFIS WALL SYSTEM (IF USED) | | | 5/8? AQUA ROCK SHEATHING | | | ROLL UP DOOR | | | WOOD BASE STRUCTURAL PANELSFBC 2315.1.11 | | | | | | | | | B-4 FBC2405PROVIDE DESIGN LOADS ON ALL WINDOW , | | | DOOR, COMPONENTS ON SCHEDULE | | | 1. NEGATIVE WIND LOAD - DEAD LOAD | | | 2. POSITIVE WIND LOAD + DEAD LOAD | | | 3. DEAD LOAD + 1/2 POSITIVE WIND LOAD | | | WIND LOADS SHALL BE DETERMINED FROM 1606. THE DEAD LOAD | | | FOR THE GLASS IN LB/SQ FT SHALL BE TAKEN AS THE TOTAL | | | THICKNESS OF THE GLASS PANES AND PLIES IN INCHES X 13. | | | THIS APPLIES FOR GLASS 30 DEGREES OR LESS FROM | | | HORIZONTAL. FOR OTHER SLOPES THE GLASS DEAD LOAD IS | | | EQUAL TO THIS VALUE TIMES THE COSINE OF ITS SLOPE FROM | | | HORIZONTAL. | | | | | | | | | B-5 FBC2411.3.1.4 THE ARCHITECT OR PROFESSIONAL | | | ENGINEER OF RECORD SHALL BE | | | REQUIRED TO SPECIFY THE DESIGN WIND PRESSURE, | | | DETERMINED IN ACCORDANCE | | | WITH CHAPTER 16 (HIGH VELOCITY HURRICANE ZONES), FOR | | | ALL GARAGE DOORS, | | | SKYLIGHTS OPERATIVE WINDOWS AND FIXED GLAZING.THE | | | DESIGN WIND PRESSURE | | | FOR EACH COMPONENT OF THE EXTERIOR BUILDING SURFACE, | | | SHALL BE | | | INCORPORATED INTO THE BUILDING DESIGN DRAWING SO AS TO | | | ALLOW THE | | | RESPECTIVE MANUFACTURER TO SIZE THE PREFABRICATED | | | ASSEMBLY FOR THE | | | PROPER WIND PRESSURES. | | | COMMENTPLEASE PROVIDE THIS INFORMATION ON THE | | | ELEVATIONS | | | | | | | | | C FBC105.13 THRESHOLD BUILDING | | | 105.13.2 THE SPECIAL INSPECTOR SHALL INSPECT THE | | | SHORING AND RE-SHORING | | | FOR CONFORMANCE TO THE SHORING AND RE-SHORING PLANS | | | SUBMITTED TO THEENFORCING AGENCY.A FEE SIMPLE TITLE | | | OWNER OF A BUILDING WHICH DOES NOT MEET THE MINIMUM | | | SIZE, HEIGHT, OCCUPANCY, OCCUPANCY CLASSIFICATION OR | | | NUMBER-OF-STORIES CRITERIA WHICH WOULD RESULT IN | | | CLASSIFICATION AS A THRESHOLD BUILDING UNDER | | | ?553.71(7) FLORIDA STATUTES, MAY DESIGNATE SUCH | | | BUILDING AS A THRESHOLD BUILDING, SUBJECT TO MORE THAN | | | THE MINIMUM | | | NUMBER OF INSPECTIONS REQUIRED BY THE FLORIDA BUILDING | | | CODE, BUILDING. | | | COMMENTPLEASE FURNISH A SHORING AND RE-SHORING PLAN | | | | | | | | | | | | | | | | | | | | | | | | D SITE PLAN AND ASSOCIATED COMPONENTS REQUIRED3RD | | | REQUEST(NOT INCLUDED) | | | (A) PARKING SPACES LOCATED OUTSIDE AND UNDERNEATH THE | | | BUILDING. CURBING, RAMPS, ACCESSIBLE ISLES FOR THE | | | HANDICAP, SIGNAGE, SIDEWALKS, CURB CUTS, PEDESTRIAN | | | CROSS WALKS | | | (B) HANDICAP SPACES LOCATED OUTSIDE AND UNDERNEATH THE | | | BUILDING PERIMETER. IDENTIFY ALL HANDICAP PARKING | | | SPACES AS DEFINED BY THEAMERICANS WITH DISABILITIES | | | FLORIDA BUILDING CODE CHAPTER 11 PART BANSIA117-1 | | | ANDFAIR HOUSING ACT GUIDELINES | | | (C) IDENTIFY THE ACCESSIBLE ROUTE AS DEFINED BY | | | THE AMERICANS WITH DISABILITIES- FLORIDA BUILDING | | | CODE CHAPTER 11 AND FAIR HOUSING ACT GUIDELINES | | | (D) IDENTIFY VAN ACCESSIBLE PARKING SPACES UNDER | | | BUILDING AND EXTERIOR IN COMPLIANCE WITH THE AMERICANS | | | WITH DISABILITIES FLORIDA BUILDING CODE CHAPTER 11AND | | | FAIR HOUSING ACT GUIDELINES, NOTE PARKING SPACES FOR | | | VANS SHALL HAVE VERTICAL CLEARANCE OF 98? | | | (E) ONE ACCESSIBLE ROUTE FAIR HOUSING, FROM THE | | | BOUNDARY SITES PUBLIC TRANSPORTATION STOP TO AN | | | ACCESSIBLE BUILDING ENTRANCE. CHAPTER 11, PART B ? | | | ANSI A117.1,502.6 | | | COMMENTPLEASE FURNISH A SEPARATE SITE PLAN FOR | | | BUILDING NO 1. INCLUDE ALL INFORMATION REQUESTED FOR | | | COMPLIANCE. | | | | | | E FBC411.2 AUTOMOBILE PARKING GARAGES | | | 411.2.1 AUTOMOBILE PARKING GARAGES SHALL BE CLASSIFIED | | | AS EITHER OPEN, AS DEFINED IN 411.3, OR ENCLOSED AND | | | SHALL MEET THE APPROPRIATE CRITERIA OF 411.3 OR 411.4. | | | | | | E-1 FBC411.3ENCLOSED PARKING GARAGES | | | | | | FBC 411.4.1 ENCLOSED AUTOMOBILE PARKING GARAGES AND | | | PORTIONS THEREOF WHICH DO NOT MEET THE DEFINITION OF | | | OPEN PARKING GARAGES SHALL BE LIMITED TO THE ALLOWABLE | | | HEIGHTS AND AREAS SPECIFIED IN TABLE 500 FOR GROUP S | | | BUILDINGS. | | | 411.4.2 A MECHANICAL VENTILATION SYSTEM FOR THE | | | REMOVAL OF THE PRODUCTS OF COMBUSTION SHALL BE | | | PROVIDED IN ENCLOSED AUTOMOBILE PARKING GARAGES. THE | | | MECHANICAL SYSTEM SHALL BE CAPABLE OF PROVIDING AT | | | LEAST 6 AIR CHANGES PER HOUR FOR EACH LEVEL. UNDER | | | NORMAL USE THE VENTILATION OF THE | | | ENCLOSED AUTOMOBILE PARKING GARAGE SHALL COMPLY WITH | | | THE VENTILATION REQUIREMENTS OF 411.5. | | | 411.2.2 THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN | | | VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT BE LESS | | | THAN 7? | | | | | | E-2 FBC 411.3 OPEN PARKING GARAGES411.3.1 | | | OPEN AUTOMOBILE PARKING GARAGES WITH ROOF PARKING MAY | | | BE CONSTRUCTED TO THE ALLOWABLE HEIGHTS AND AREAS | | | SPECIFIED IN TABLE 411.3.1. TO BE CONSIDERED OPEN, THE | | | GARAGE SHALL MEET THE REQUIREMENTS OF411.3.2, | | | 411.3.3 AND411.3.4. | | | | | | 411.3.2 THE EXTERIOR AND INTERIOR WALLS OF THE GARAGE | | | SHALL BE DESIGNED IN ACCORDANCE WITH ONE OF THE | | | FOLLOWING: | | | 1. AT LEAST 50 PERCENT OF THE CLEAR HEIGHT BETWEEN | | | FLOORS SHALL BE OPEN TO THE ATMOSPHERE FOR THE FULL | | | LENGTH OF AT LEAST TWO EXTERIOR WALLS, EXCLUDING | | | REQUIRED STAIR AND ELEVATOR WALLS AND STRUCTURAL | | | COLUMNS. INTERIOR WALL LINES AND COLUMN LINES SHALL BE | | | AT LEAST 20 PERCENT OPEN AND UNIFORMLY DISTRIBUTED, OR | | | 2. THE EXTERIOR WALLS OF THE STRUCTURE SHALL HAVE | | | UNIFORMLY DISTRIBUTED OPENINGS ON TWO OR MORE SIDES | | | TOTALING NO LESS THAN 40 PERCENT OF THE BUILDING | | | PERIMETER. THE AREA OF SUCH OPENINGS IN THE EXTERIOR | | | WALLS ON EACH LEVEL SHALL BE AT LEAST 20 PERCENT OF THE | | | TOTAL PERIMETER WALL AREA OF EACH LEVEL. INTERIOR WALL | | | LINES AND COLUMN LINES SHALL BE AT LEAST 20 PERCENT | | | OPEN AND UNIFORMLY DISTRIBUTED. | | | COMMENTPLEASE VERIFY OPEN OR ENCLOSED WITH THE CODE | | | SECTIONS PROVIDED HEREIN | | | | | | F FBC104.3 EXAMINATION OF DOCUMENTS | | | 104.3.1 PLAN REVIEW. THE BUILDING OFFICIAL SHALL | | | EXAMINE OR CAUSE TO BE EXAMINED EACH APPLICATION FOR A | | | PERMIT AND THE ACCOMPANYING DOCUMENTS, CONSISTING OF | | | DRAWINGS, SPECIFICATIONS, COMPUTATIONS AND ADDITIONAL | | | DATA, AND SHALL ASCERTAIN BY SUCH EXAMINATIONS WHETHER | | | THE CONSTRUCTION INDICATED AND DESCRIBED IS IN | | | ACCORDANCE WITH THE REQUIREMENTS OF THE TECHNICAL CODES | | | AND ALL OTHER PERTINENT LAWS OR ORDINANCES. | | | COMMENTSHEETAP S3.12PARTIAL 2ND FLOOR PLAN DETAIL | | | 11-S4.21AT ?SLAB OPEN AREA NO SLAB? | | | THIS DETAIL IS FOR THE ELEVATOR AND STAIRWAY, PLEASE | | | CLARIFY. | | | G FBC106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS ARE | | | PERMITTED TO BE SUBMITTED WHEN APPROVED BY THE BUILDING | | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | | BY THE BUILDING OFFICIAL (SEE ALSO SECTION 106.3.5 ). | | | COMMENT-IDENTIFY EXPANSION JOINT MATERIAL.PROVIDE | | | MANUFACTURER SPECIFICATIONS | | | | | | G-1 COMMENT- DEFINE BUILT UP ROOFING ELEVATIONS FOR | | | POSITIVE DRAINAGE ON THE FOLLOWING PLAN SHEETS | | | AP-A5.05,AP-A5.10,AP-A5.20 | | | | | | G-2 COMMENT- WALL SECTIONS REFER TO SHEET A1.04. | | | PLEASE FURNISH THE I.D. SHEET GN-A1.04 | | | | | | G-3 COMMENT- SOME OF THE WALL SECTIONS ON THE | | | ARCHITECTURAL FLOOR PLANS DO NOT MATCH THE INTENDED | | | UNIT DETAILS BECAUSE, VARIOUS WALLS ARE END WALLS AND | | | OTHERS ARE LOCATED NEAR A STAIRWAY. PLEASE IDENTIFY THE | | | WALL SECTIONS ON THE ARCHITECTURAL FLOOR PLANS THAT ARE | | | APPLICABLE FOR ITS CONDITION. | | | | | | G-4 COMMENT- CLUBHOUSE OCCUPANCY IS RATED A. PLEASE | | | ADD TO SHEET GN-A1.02 | | | | | | H FLORIDA ACCESSIBILITY CODE CHAPTER 11 | | | COMMENT-MEN?S BATHROOM WALL PARTITIONS ARE | | | ENCROACHING INTO TOILET ROOM SEE ADA FIG 28 | | | WOMEN?S BATHROOMWALL PARTITIONS ARE ENCROACHING INTO | | | TOILET ROOM SEE ADA FIG 28 | | | DETAIL ALL BATHROOM ACCESSORIES, GRAB BARS, TOILET | | | PAPER HOLDER, PAPER TOWEL DISPENSER, MIRROR | | | PLEASE NOTE THE BATHROOMS ARE NOT CONSIDERED A STALL | | | | | | H-1 FLORIDA ACCESSIBLE CODE11-4.10 ELEVATORS | | | 11-4.10.9 FLOOR PLAN OF ELEVATOR CARS. THE FLOOR AREA | | | OF ELEVATOR CARS SHALL PROVIDE SPACE FOR WHEELCHAIR | | | USERS TO ENTER THE CAR, MANEUVER WITHIN REACH OF | | | CONTROLS, AND EXIT FROM THE CAR. ACCEPTABLE DOOR | | | OPENING AND INSIDE DIMENSIONS SHALL BE AS SHOWN IN | | | FIGURE 11-22. THE CLEARANCE BETWEEN THE CAR PLATFORM | | | SILL AND THE EDGE OF ANY HOIST WAY LANDING SHALL BE NO | | | GREATER THAN 1-1/4 INCHES (32 MM). | | | COMMENTAP-A8.10 PROVIDE A FLOOR PLAN OF THE | | | ELEVATOR CAB UTILIZING THIS SECTION OF THE ADA | | | | | | H-2 FBC1814.1ELEVATOR PIT | | | COMMENTAP-A8.10 WHERE REQUIRED. WHERE A | | | GROUNDWATER TABLE INVESTIGATION INDICATES THAT | | | HYDROSTATIC PRESSURE CONDITIONS EXIST, WALLS AND FLOORS | | | RETAINING EARTH AND ENCLOSING SPACES BELOW FINISHED | | | GROUND LEVEL SHALL BE WATERPROOFED IN ACCORDANCE WITH | | | ?1814.2. WHERE HYDROSTATIC PRESSURE CONDITIONS DO NOT | | | EXIST, DAMP PROOFING AND PERIMETER DRAINAGE SHALL BE | | | PROVIDED IN ACCORDANCE WITH 1814.3. | | | | | | I FBC1003.2 | | | COMMENT-AP-A8.01SECTION 15? PLEASE DETAIL THE | | | STAIRWAYS FOR TREAD DEPTH, CHANGES AT LANDINGS AND | | | HEADROOM CLEARANCE FROM TREAD TO BEAM ABOVE. | | | | | | J FBC1606STRUCTURAL LOADS | | | COMMENT-SUBMIT ENGINEERING DESIGN FOR THE BALCONY | | | RAILINGS IN COMPLIANCE WITH THIS SECTION. | | | | | | K FBC1404.1.1ARCHITECTURAL TRIMABOVE 3 STORIES OR | | | 40 FT | | | COMMENT-IDENTIFY THE FASTENING HARDWARE TO BE USED | | | IN SECURING THE FOAM TRIM TO THE BUILDING EXTERIOR | | | SURFACE | | | | | | L FBC705PROTECTION OF OPENINGS AP-A8.20 | | | IDENTIFY THE FIRE RATING FOR THE TRASH CHUTE DOORS | | | | | | | | | | | | PREVIOUS PLAN REVIEWER?S COMMENTSDATED5/22/07 | | | | | | 12B) 3RD REQUEST: | | | PLEASE INCORPORATE THE CIVIL DRAWINGS INTO THIS PLAN | | | FOR REVIEW, NOT A NOTE REFERENCING CHAPTER 11. | | | THE ACCESSIBLE ROUTE MUST BE DESIGN, REVIEWED AND | | | CONSTRUCTED BY THE PLAN. | | | SEE THIS PLAN REVIEWER?S COMMENT ITEM ?D? | | | | | | 12B1) PLEASE PROVIDE INFORMATION FOR VAN | | | ACCESSIBILITY. SEE THIS PLAN REVIEWER?S COMMENT ITEM | | | ?D? | | | | | | 12B2) PLEASE PROVIDE A DETAIL OF THE SIGN WITH THE | | | HANDICAP SYMBOLS AND COLORS. PROVIDE A DETAIL OF THE | | | POLE HEIGHT FROM THE EXTERIOR GRADE TO THE SIGN AS PER | | | FA CHAPTER 11 | | | | | | 12C) PLEASE PROVIDE A SITE PLAN WITH PARKING UNDERNEATH | | | THE BUILDING, CURB CUTS,PEDESTRIAN CROSS WALKS, | | | RAMPS, HANDICAP TEXTURE SURFACES ON THE RAMPS, RAMP | | | WIDTH, RAMP PITCH, RAMP CONNECTION TO SIDEWALK. | | | | | | 14E) THIS COMMENT IS REQUESTING A REFERENCE TO A DROP | | | CEILING IN THE LEASING OFFICE CLOSET. | | | CUT SECTION AP-A7.04 DETAIL IS A STAIR LANDING DETAIL | | | ??? | | | | | | 22C) ARCHITECTURAL TRIM LOCATED ABOVE 40?. | | | SEE THIS PLAN REVIEWER?S COMMENT K. PROVIDE THE TYPE OF | | | FASTENERS, SIZE, LENGTH, SPACING OF FASTENERS AND ALL | | | RELATED HARDWARE, AS TO GAUGE OF METAL, DESCRIPTION, | | | | | | 23) PRODUCT APPROVALS PLEASE SUBMIT THIS IS THE 3RD | | | REQUEST | | | SEE THIS PLAN REVIEWER?S COMMENT B | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-02-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-02-14 |
Time |
09:35 |
Rev Time |
10.00 |
| Received By |
jwitmer |
Date |
2007-02-06 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2007-02-14 09:39:42 | BUILDING PLAN REVIEW | | | PERMIT: 05091684 BLDG# 1 | | | ADD: XXX N CONGRESS | | | 74-43-43-20-00-000-3010 | | | CONT: E. A. LANDERS | | | TEL: (305)823-3938 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | COURTNEY LAKES APARTMENTS, LLC | | | | | | ARCH: FORUM ARCHITECTURE & INTERIOR | | | | | | | | | DESIGN | | | (407)830-1400 | | | STRUC: ROBERT PLOWFIELD & ASSOC | | | (407)657-6657 | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | ***IMPORTANT*** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK OF COURT BEFORE | | | A PERMIT CAN BE ISSUED. | | | NOTE NOC WILL BE NULL & VOID 90 DAYS AFTER RECORDING AT | | | THE CLERK OF THE | | | COURTS OFFICE IF WORK HAS NOT STARTED. FL S S | | | 713.13(2). | | | | | | 2) THIS COMMENT WAS PARTIALLY SATISFIED, FOR THE WHOLE | | | OF THE PROJECT (3 BUILDINGS) | | | THREE SIGNED & SEALED REPORTS WERE SUBMITTED TO THE | | | CITY. THIS WILL SATISFY THE REQUIREMENT | | | TO HAVE (1 ) REPORT WITH EACH PERMIT OR BUILDING. THE | | | NEED STILL ARISES TO HAVE AT LEAST ONE SIGNED/ SEALED | | | ORIGINAL FOR THE CONTRACTOR AS WELL AS THE THRESHOLD | | | INSPECTOR. | | | AN ADDITIONAL 2 ORIGINAL SOILS REPORTS SIGNED & SEALED | | | SHALL BE REQUIRED. | | | FL BLD CODE 1804.2.2 QUESTIONABLE SOILS, WHERE THE | | | BEARING CAPACITY IS NOT DEFINETLY KNOWN OR IS IN | | | QUESTION. WHERE THE BEARING CAPACITY OF THE SOIL IS NOT | | | DEFINITLY KNOWN OR IS IN QUESTION THE BUILDING OFFICIAL | | | MAY REQUIRE EXPLORATIONS, TEST OR OTHER ADEQUATE PROOF | | | AS TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDATIONS SUBMITTED | | | TO VERIFY BEARING CAPACITY SHALL BE CERTIFIED BY A | | | GEOTECHNICAL REPORT FROM A DESIGN PROFESSIONAL PROPERLY | | | LICENSED IN THE STATE OF FLORIDA. | | | | | | 3-4) COMPLIED. | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT SET OF PLANS MUST BE | | | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL | | | (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 6)FL S. S. 553.71(7) " THRESHOLD BUILDING" MEANING | | | ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN HEIGHT, OR WHICH | | | HAS AN ASSEMBLY OCCUPANY | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ FT IN | | | AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 105.13.1 THE ENFORCING AGENCY SHALL REQUIRE A | | | SPECIAL INSPECTOR TO PERFORM | | | STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING PURSUANT | | | TO A STRUCTURAL INSPECTION PLAN PREPARED BY THE | | | ENGINEER OF RECORD. THE STRUCTURAL INSPECTION PLAN MUST | | | BE SUBMITTED TO THE ENFORCING AGENCY PRIOR TO THE | | | ISSUANCE OF A BUILDING PERMIT FOR THE CONSTRUCTION OF A | | | THRESHOLD BUILDING. THE PURPOSE OF THE STRUCTURAL | | | INSPECTION PLAN IS TO PROVIDE SPECIFIC INSPECTION | | | PROCEDURES AND SCHEDULES SO THAT THE BUILDING CAN BE | | | ADEQUATELY INSPECTED FOR COMPLIANCE WITH THE PERMITTED | | | DOCUMENTS. | | | THE THRESHOLD REPORTS SUBMITTED HAVE COPIED | | | SIGNATURES. | | | | | | 7) WPB AMENDMENT 105.13.6. W.P.B. CONSTRUCTION SERVICES | | | DEPARTMENT REQUEST FOR THRESHOLD BUILDINGS A SPECIAL | | | INSPECTOR AS REQUIRED BY S. 553.79(5) FLORIDA STATUTES | | | TO THE MINIMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) 805-6711 FOR FURTHER | | | INFORMATION BEFORE THE PERMIT MAY BE ISSUED. | | | | | | 8) COMPLIED. | | | | | | 9A) CONTACT LILI URSA FOR ADDRESSING REQUIREMENTS @ | | | (561)822-1239 | | | | | | 9B)PROVIDE A COPY OF THE NEW PLAT, LOT HAS BEEN | | | SUBDIVIDED. | | | | | | 9C) ON ALL (3) PERMIT APPLICATIONS CORRECT THE PROPERTY | | | CONTROL NUMBER TO | | | THE NEW LOT. | | | | | | 9D) PROVIDE A SITE PLAN WITH LOCATION OF THE PROPOSED | | | STRUCTURES WITH DIMENSIONS | | | FOR TABLE 600 ISSUES.A2.01 HAS NO DIMENSIONS!RESPONSE | | | COMMENTS ARE TO SEE CIVIL PLANS ,NO CIVIL PLANS | | | PROVIDED IN THIS SET OF PLANS. | | | | | | | | | 10A-K) COMPLIED. | | | | | | 11) SHEET A1.05 | | | | | | 11A-B) COMPLIED. | | | | | | 12)SITE PLAN A5.01 | | | NEW COMMENT THAT DEALS WITH THE OVER ALL PARKING SPACES | | | AND THE REQUIRED NUMBER OF ACCESSIBLE SPACES. THE PLANS | | | INDICATE A TOTAL OF 912 SPACES WHERE AS IT APPEARS TO | | | BE 1008 PARKING SPACES IF THIS IS TRUE THE REQUIRED | | | NUMBER OF ACCESSIBLE SPACES WOULD BE 21. | | | CHAPTER 11 PART B- 4PARKING AND PASSENGER LOADING: | | | ACCESSIBLE PARKING ON A ROUTE ACCESSIBLE TO WHEELCHAIRS | | | FOR AT LEAST 2% OF THE COVERED DWELLING UNITS: | | | ACCESSIBLE VISITOR PARKING SUFFICIENT TO PROVIDE ACCESS | | | TO GRADE LEVEL ENTRANCES OF COVERED MULTIFAMILY | | | DWELLINGS; AND ACCESSIBLE PARKING AT FACILITIES (E.G., | | | SWIMMING POOLS) THAT SERVE ACCESSIBLE BUILDINGS. | | | | | | 12A) COMPLIED. | | | | | | 12B)2ND REQUEST, THERE ARE NO CIVIL PLANS INCORPORATED | | | INTO THIS SET OF PLANS TO REVIEW FOR ACCESSIBILITY. | | | ACCESSIBLE ROUTE: FAIR HOUSING AT LEAST ONE ACCESSIBLE | | | ROUTE SHALL BE PROVIDED WITHIN THE BOUNDARY OF THE SITE | | | FROM PUBLIC TRANSPORTATION STOPS, ACCESSIBLE PARKING | | | SPACES, PASSENGER LOADING ZONES IF PROVIDED, AND PUBLIC | | | STREETS OR SIDEWALKS, TO AN ACCESSIBLE BUILDING | | | ENTRANCE. | | | 12B)(1) PLEASE PROVIDE INFORMATION WHICH ACCESSIBLE | | | PARKING SPACES WILL BE THE VAN A VERTICAL CLEARANCE OF | | | 98" MINIMUM AT THE SPACE AND ALONG THE VEHICULAR ROUTE | | | THERETO. | | | | | | 12B)(2) PLEASE PROVIDE SIGNAGE FOR ALL ACCESSIBLE | | | PARKING SPACES . CHAPTER 11 PART B ANSI A117.1502.6. | | | | | | 12C) THE SITE PLAN DOES NOT PROVIDE FOR HANDICAPPED | | | PARKING UNDER THE BUILDING | | | # 1, ANS1 A117.1, 4.6 PARKING AND PASSENGER LOADING | | | ZONES, EQUIVALENT FACILITATION. | | | | | | 12D) SITE PLAN DOES NOT PROVIDE ANYINFORMATION AS TO | | | CURB CUTS, PEDESTRIAN CROSS WALKS, ETC. | | | | | | 13) SHEET A5.01; | | | | | | 13A-E) COMPLIED. | | | | | | 13F) 2ND REQUEST, THEFIRE PUMP ROOM NO RATING OF | | | WINDOW OR OPENING ?U? NOT IN WINDOW SCHEDULE. DOOR | | | 1.01IS NOW RATED- OK. | | | | | | 13G-J) COMPLIED. | | | | | | 13K) NEW COMMENT : SHEET A5.05 INDICATES THE ROOF DECK, | | | THE PLAN DOESN?T INDENTIFY THE DOORS FROM THE | | | STAIRWELLS FOR ROOF ACCESS. | | | 14)DETAILS ON A5.70: | | | | | | 14A-D) COMPLIED. | | | | | | 14E) 2ND REQUEST, THE LEASING OFFICETHE CUT SECTION | | | PROVIDED AP A7.04 DETAIL# 4 DOES INDICATE A DROPPED | | | CEILING IN THE CLOSET BUT NO INFORMATION IS PROVIDED AS | | | TO THE CEILING AND WALL RATING OF THE CLOSET.1007.1.4. | | | | | | | | | 15) SHEET A5.02: | | | | | | 15A-G) COMPLIED. | | | 15B) UNDERSTOOD THAT THE STAIRS ARE TO BE CONSIDERED | | | OPEN STAIRS, BUT THE CORRIDOR WILL STILL REQUIRE A WALL | | | RATING, IT CAN NOT BE CONSIDERED AN OPEN BALCONY. | | | PLEASE PROVIDE THE RATING FOR THE CORRIDOR. PLANS NOW | | | INDICATE THE UNIT ENTRY DOORS BEING FIRE RATED. | | | | | | 15H) SHEET A5.04 TYPICAL 5TH FLOOR ELEVATOR DETAIL | | | 2/A8.10 : | | | NEW COMMENT:SHEET A5.04 INDICATES AN ELEVATOR | | | DETAIL 2 /A8.10 , THIS ELEVATOR MACHINE ROOM DOES NOT | | | INDICATE WALL OR DOOR RATINGS. | | | | | | 15I) NEW COMMENT: SHEET A5.05 STAIRWELL ACCESS TO ROOF. | | | SEE 1008 SUCH STAIRWAY SHALL BE MARKED AT STREET AND | | | FLOOR LEVELS WITH A SIGN INDICATING THAT IT CONTINUES | | | TO THE ROOF. | | | | | | 15J) NEW COMMENT: SHEET A7.02 WALL SECTION# 3& A7.03 | | | WALL SECTION# 1, DETAIL#21/ A7.10 INDICATES THE USE | | | OF WHAT APPEARS TO BE EFIS WALL SYSTEMS, THERE IS A | | | WALL IDENTITY TAG W1-14 , NO SUCH TAG ON SHEET A1.04? | | | | | | 15K) NEW COMMENT: SHEET A7.02 KEY NOTE # 10 NOTES SEE | | | STRUCTURAL DRAWINGS FOR ROOF TRUSS ANCHORAGE, NO | | | TRUSSES NEAR THE NOTE, WHY IS THE BAT INSULATION ON THE | | | FLOOR? | | | | | | 16) SHEET A5.71: | | | | | | 16A-B) COMPLIED. | | | | | | 17) SHEET A5.20. COMPLIED. | | | | | | 18) SHEET A5.10: | | | | | | 18A) 2ND REQUEST, TRASH ROOM DETAIL4 OF A8.20 THE | | | DETAIL IS INDICATING THE OPENING FROM THE CHUTE TO THE | | | ACCESS ROOM. | | | PLANS INDICATE A DETAIL 22 ON SHEET A7.10, SEE KEY NOT | | | MARKER 13 & 23, BOTH APPEAR TO BE INCORRECT. | | | | | | 18B) COMPLIED. | | | | | | 18C) 2ND REQUEST THERE IS NO INFORMATION ON THE | | | COMBUSTIBILITY OF THE TRASH CHUTE NOR | | | ON AUTOMATICALLY CLOSING OPENINGS. 705.2.4.2. LOOKING | | | FOR A SPEC INDICATING THE GAUGE OF METAL USED IN THE | | | CHUTE, ETC. | | | | | | 18D-E) COMPLIED. | | | | | | 19) SHEET A5.11 IS FOR THE FIRST FLOOR ABOVE THE GARAGE | | | FLOOR: | | | | | | 19A-C) COMPLIED. | | | | | | 20) COMPLIED. | | | | | | 21) SHEET A5.22 | | | | | | 21A) COMPLIED. | | | | | | 22) VARIOUS SHEETS ON BUILD 1,2 & 3 | | | INDICATE A DETAIL SECTION# 23 SHEET | | | A7.10. | | | | | | 22A) COMPLIED. | | | | | | 22B) COMPLIED. | | | | | | 22C) 2ND REQUEST, THIS SAME SECTION INDICATES USE OF | | | FOAM TRIM ON THE EXTERIOR OF THE BUILDING ABOVE 40'. | | | 1404.1.1 ARCHITECTURAL TRIM ON BUILDINGS OF TYPE I, II | | | AND IV CONSTRUCTION NOT MORE THANTHREE STORIES OR 40 | | | FT (12.2 M) HIGH MAY BE OFTYPE VI CONSTRUCTION, AND | | | MAY BE | | | OF TYPE VI CONSTRUCTION ON ALL BUILDINGS OF TYPE III, V | | | AND VI CONSTRUCTION. TRIM SHALL BE SECURED TO THE WALL | | | WITH METAL OR OTHER APPROVED BRACKETS OR FASTENERS. | | | WHEN ARCHITECTURAL TRIM IS LOCATED ALONG THE TOP OF | | | EXTERIOR WALLS, IT SHALL BE COMPLETELY BACKED BY THE | | | EXTERIOR WALL AND SHALL NOT EXTEND OVER THE TOP OF | | | EXTERIOR WALLS. | | | | | | 23) PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO | | | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE | | | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, | | | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR | | | SITE SPECIFIC FORM PER RULE 9B-72. SEE ATTACHMENT. | | | WWW.FLORIDABUILDING.ORG | | | | | | 24) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS, MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) OPERABLE WINDOWS | | | FL 3485TRACO TR-6800 -OK | | | FL 3044.3TRACO HS-HC 65 NON-IMPACT WINDOW | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | FL 3044.4TRACO HS-AW 55NON-IMPACT WINDOW | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | FL 3044.5TRACO HS-AW55 NON-IMPACT WINDOW | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | | | | B) FIXED WINDOWS | | | FL 3487TRACOTR-3800 - OK | | | FL 632KAWNEER EXPIRED NOA NON-IMPACT | | | REQUIRED 0-30'LARGE MISSILE, 30'-60'SMALL MISSILE - | | | DENIED | | | | | | C) MULLIONS MAY OR MAY NOT BE INCLUDED IN THE PRODUCT | | | APPROVALS | | | | | | D) EXTERIOR HOLLOW METAL DOORS | | | FL3078 AMWELD DENIED LOW PRESSURES SINGLE & | | | PAIRS | | | | | | E) EXTERIOR GLAZED DOORS | | | FL 3038TRACO 03-0829.06 SMALL MISSILE ONLY, NO | | | PRESSURE TEST - DENIED | | | FL 3038.3TRACO 03-0422.04 TR-8910 SMALL | | | MISSILE TEST NO PRESSURE TEST - DENIED | | | FL 3038.4TRACO 03-0422.04 TR-8910 LARGE | | | MISSILE HIGHLIGHT ANCHOR FASTENING SCHEDULE MAY COMPLY | | | FL3477TRACO TR-8300SLIDING GLASS DOOR | | | NON-IMPACTREQUIRES 0-30' LARGE MISSILE, 30'-60' SMALL | | | MISSILE - DENIED | | | | | | F) EXTERIOR LOUVERED DOORS NO REPORT SUBMITTED | | | | | | G) EXTERIOR RAILINGS- WILL ONLY NEED ENGINEERING NOT A | | | PRODUCT APPROVAL | | | | | | H) LOUVERS NO REPORT SUBMITTED. | | | | | | I) TRUSS ANCHORS NO REPORT SUBMITTED. | | | | | | J) ROOF ASSEMBLIES INCLUDING DENSE DECK, INSULATION, | | | UNDERLAYMENT, ROOF TILE AND ATTACHMENT METHODS. FL 1559 | | | SINGLE PLY ROOF SYSTEMS- HIGHLIGHT WHICH SUB-SYSTEM TO | | | BE USED. | | | NOTE ZONES 2 & 3 MAY REQUIRE ENHANCED FASTENING | | | PROVIDE RATIONAL ANALYSIS BY QUALIFIED PROFESSIONAL | | | | | | K) EFIS WALL SYSTEMS IF USED | | | | | | L)5/8" FIBER TOUGH AQUA ROCK SHEATHING | | | | | | M ) PRE-MANUFACTURED ROOF A/C STANDS- OK | | | | | | N) ROLL UP DOOR - NO REPORT SUBMITTED | | | | | | O) DENSE DECK- MAY BE INCORPORATED IN A PRODUCT | | | APPROVAL | | | | | | P) ROOF TILE - NO REPORT SUBMITTED- CIRCLE OR HIGHLIGHT | | | WHAT ANCHOR METHOD TO INSTALLROOF TILE | | | | | | 25- 27) COMPLIED, IMPACT GLASS IS SPECIFIED. | | | | | | 28) COMPLIED, IMPACT GLASS IS SPECIFIED. | | | | | | 29- 31) COMPLIED. | | | | | | 32- 35) COMPLIED. | | | | | | NOTE: CALCULATED VALUE OF THIS TYPE II BUILDING IS | | | $39,353,983.00 | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | | | | COURTNEY LAKES BLDG 1 ? 2NDREV.DOC |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-02-01 |
Time |
07:38 |
Rev Time |
22.00 |
| Received By |
jwitmer |
Date |
2006-02-01 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2006-01-31 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05091684 | | | ADD:XXX N CONGRESS | | | 74-43-43-20-00-000-3010 | | | CONT: E. A. LANDERS | | | TEL: (305)823-3938 | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | COURTNEY LAKES APARTMENTS, LLC | | | | | | ARCH: FORUM ARCHITECTURE & INTERIOR | | | | | | DESIGN | | | (407)830-1400 | | | STRUC: ROBERT PLOWFIELD & ASSOC | | | (407)657-6657 | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | ***IMPORTANT*** | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | NOTE NOC WILL BE NULL & VOID 90 DAYS | | | AFTER RECORDING AT THE CLERK OF THE | | | COURTS OFFICE IF WORK HAS NOT STARTED. | | | FL S S 713.13(2). | | | | | | 2) FL BLD CODE 1804.2.2 QUESTIONABLE | | | SOILS, WHERE THE BEARING CAPACITY IS | | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | | WHERE THE BEARING CAPACITY OF THE SOIL | | | IS NOT DEFINITLY KNOWN OR IS IN QUESTION | | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | | TO THE PERMISSIBLE SAFE BEARING | | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | | NICALREPORT FROM A DESIGN PROFESSIONAL | | | PROPERLY LICENSED IN THE STATE OF | | | FLORIDA. | | | | | | 3) FL BLD CODE CHAP 13 ENERGY EFFICENCY | | | PROVIDE ENERGY CALS/ W MANUAL "J" | | | | | | 4) ARCHITECTURAL PAGES DO NOT HAVE A | | | RAISED SEAL. | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND | | | BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 5)BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 6)FL S. S. 553.71(7) " THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN | | | CY CLASSIFICATION AS DEINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL INSPEC | | | TION PLAN PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING AGEN- | | | CY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESH- | | | OLD BUILDING. THE PURPOSE OF THE SRUCTUR | | | AL INSPECTION PLAN IS TO PROVIDE SPECIF- | | | IC INSPECTION PROCEDURES AND SCHEDULES | | | SO THAT THE BUILDING CAN BE ADEQUATELY | | | INSPECTED FOR COMPLIANCE WITH THE | | | PERMITTED DOCUMENTS. | | | | | | 7) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 8) W.P.B. AMENDMENT 105.13.4.4 ALL PLANS | | | FOR THE BUILDING WHICH ARE REQUIRED TO | | | BE SIGNED AND SEALED BY THE ARCHITECT OR | | | ENGINEER OF RECORD CON- TAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR | | | ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 9A) CONTACT LILI URSA FOR ADDRESSING | | | REQUIREMENTS @ (561)822-1239 | | | | | | 9B)PROVIDE A COPY OF THE NEW PLAT, LOT | | | HAS BEEN SUBDIVIDED. | | | | | | 9C) ON ALL (3) PERMIT APPLICATIONS | | | CORRECT THE PROPERTY CONTROL NUMBER TO | | | THE NEW LOT. | | | | | | 9D) PROVIDE A SITE PLAN WITH LOCATION OF | | | | | | THE PROPOSED STRUCTURES WITH DIMENSIONS | | | FOR TABLE 600 ISSUES.A2.01 HAS NO | | | DIMENSIONS! | | | | | | 10A) CORRECT PERMIT APPLICATIONS AS TO | | | DESRIPTION OF WORK FOR THE THREE | | | BUILDINGS, CURRENTLY THERE WILL BE 1350 | | | UNITS ON THIS PROJECT WHEN FINISHED, SEE DESCRIPTION OF | | | PROJECT, EACH APPLICATION | | | FOR BUILDINGS 1, 450 UNITS BUILDING 2 | | | 450 UNITS & BUILDING 3, 450 UNITS | | | TOTALING 1350. . | | | | | | 10B) PLEASE PULL PLANS APART INTO 3 SETS | | | OF PLANS SO ALL PAGES THAT DEAL WITH | | | BUILDING # 1 ARE IN ONE SET ETC. | | | | | | 10C) ADDITIONAL INFORMATION REQUIRED FOR | | | RECORD KEEPING PURPOSES 106.1.2*: | | | 10C)A) FLOOD ZONE | | | 10C)B) FLOOD ELEVATION (IF A ZONE) | | | 10C)C) LOMAR (IF A ZONE) | | | 10C)D) NUMBER OF UNITS | | | 10C)E) NUMBER OF FLOORS | | | 10C)F) NUMBER OF BEDROOMS | | | 10C)G) NUMBER OF ROOMS | | | 10C)H) NUMBER OF BATHROOM | | | 10C)I) SQ FT LIVING SPACE(TOTAL) | | | 10C)J) SQ FT FOOT PRINT | | | 10C)K) SQ FT UNDER ROOF (TOTAL) | | | | | | 10D) THE DESCRIPTION OF BUILDINGS AND | | | PHASING ARE CONFUSING BECAUSE THE | | | TERMINOLOGY, CURRENTLY THE CONTRACTOR | | | HAS PERMIT APPLICATIONS IN FOR BUILDINGS | | | 1,2& 3 NOT 4 NOR 5 AS BUILDINGS ARE | | | DEPICTED ON SHEET A1.02. | | | | | | 10E) A1.04 INDICATES A PHASED PROJECT OF | | | 5 BUILDINGS SEPERATED BY 4 HR WALLS. | | | THEN THERE IS ANOTHER NOTE INDICATING | | | TEMPORARY I HR WALLS WITH 45 MIN RATED | | | DOORS. THIS PLAN IS NOT CLEAR AS WHAT | | | WORK WILL BE COMPLETED WHEN. A MEETING | | | WITH ALL CONCERNED WOULD BE GREATLY | | | APPRECIATED. CONCERNS ON HOW EGRESS WAYS | | | ARE TO BE ADDRESSED. HOW ACTIVE FIRE | | | ALARM, FIRE SPRINKLER WILL BE MAITAINED | | | WITH THE NEW PHASES BEING BUILT. WORK | | | AREA BEING ISSOLATED FROM THE GENERAL | | | PUBLIC.A ACCESSIBLE PATH TO THE RIGHT OF | | | WAY DURING CONSTRUCTION OF ALL PHASES. | | | | | | 10F) THE PHASING PLAN INDICATED ON SHEET | | | A1.04 INDICATES WORK ON BUILDING# 1 THEN | | | JUMPING TO TWO OTHER BUILDINGS THEN BACK | | | TO BUILDING# 1 JUMPING OVER AREAS TO BE | | | PHASED IN LATER VERY IMPARTICAL AS TO | | | HOW LIVE SYSTEMS ELECTRIC WATER AND FIRE SPRINKLERS ARE | | | TO BE BUILT AND | | | MAINTAINED. | | | | | | 10G) THIS REVIEW WILL CONSTITUTE OF | | | BUILDING# 1 OF 515,540 SQ FT. PLANS | | | REFER TO THIS AS BEING BLDG 1,2 & 3. | | | | | | 10H) A1.02 CODE COMPLIANCE FOR APARTMENT BUILDINGS | | | PLANS INDICATE TYPE IV, UNPROTECTED , | | | SPRINKLERED | | | MAXIMUMHEIGHT ALLOWED IS 55' | | | PROPOSED HEIGHT69'-3" | | | PLEASE CORRECT BUILDING TYPE!!!!!! | | | 503.2.2 ALLOWED THE DEDUCTION OF 1 STORY | | | FOR THE PARKING GARAGE IF TYPE I OR TYPE | | | II BUILDING. | | | | | | 10I) THE OTHER ISSUE IS THE ALLOWABLE | | | AREA FOR A TYPE IV , UNPROTECTED, | | | SPREINKLERED BUILDING THE ALLOWABLE | | | AREAIS ONLY 24,000 SQ FT / FL. | | | | | | 10J) EVEN IF THE BUILDING WAS CONSIDERED | | | A TYPE IV , 1 HR PROTECTED, SPRINKLERED | | | BUILDING THE ALLOWABLE AREA INCREASE | | | WILL BE 36,000/ FL BUT THE HEIGHT OF 65' | | | STILL 4'-3" OF THE OVERALL HEIGH OF THE | | | BUILDING, STILL REQUIRING THE 4 FOUR HR | | | FIRE WALLS TO MAKE UP THE TOTAL AREA FOR | | | THIS ONE BUILDING. THE OTHER ISSUE IS | | | THE 4 HR FIRE WALLS DO NOT CONTINUE | | | THROUGH THE GARAGE SEPERATING THEM INTO | | | SEPERATE BUILDINGS. A 3HR FIRE RATED | | | DOOR WOULD BE REQUIRED IN THE GARAGE | | | LEVEL. PLEASE CORRECT. | | | | | | 10K) DISCREPANCY A1.02 CONSTRUCTION TYPE | | | IV UNPROTECTED VS A1.21 FIRE RATING | | | IV I HR RATED. | | | | | | 11) SHEET A1.05 | | | | | | 11A) PLEASE PROVIDE THE LISTING FOR | | | RATED WALLS, U.L. OR OTHER | | | RECOGNIZED LISTING AGENCY. | | | | | | 11B) PLANS INDICATE USE OF RINKER BLOCK, | | | PROVIDE FROM THE MANUCATURER THE | | | EQIVALENT THICKNESS OF BLOCK,709.3.1.1 | | | THE FIRE RESISTANCE RATING OF WALLS AND | | | PARTITIONS CONSTRUCTED OF CONCRETE | | | MASONRY UNITS SHALL BE DETERMINED FROM | | | TABLE 709.3.1.THE RATING SHALL BE | | | BASED ON THE EQUIVALENT THICKNESS OF THE | | | MASONRY AND TYPE OF AGGREGATE USED. | | | | | | 12)SITE PLAN A2.01 | | | | | | 12A) INDICATES HANDICAPPED SPACES BLDG# | | | 1 HAS NO HANDICAPPED PARKING SPACES | | | WITHIN THE PARKINGGARAGE? | | | | | | 12B) ACCESSIBLE ROUTE: FAIR HOUSING AT | | | LEAST ONE ACCESSIBLE ROUTE SHALL BE | | | PROVIDED WITHIN THE BOUNDARY OF THE SITE | | | FROM PUBLIC TRANSPORTATION STOPS, | | | ACCESSIBLE PARKING SPACES, PASSENGER | | | LOADING ZONES IF PROVIDED, AND PUBLIC | | | STREETS OR SIDEWALKS, TO AN ACCESSIBLE | | | BUILDING ENTRANCE. | | | | | | 12C) THE SITE PLAN DOES NOT PROVIDE FOR HANDICAPPED | | | PARKING UNDER THE BUILDING | | | # 1, ANS1 A117.1, 4.6 PARKING AND | | | PASSENGER LOADING ZONES, EQUIVALENT | | | FACILITATION. | | | | | | 12D) SITE PLAN DOES NOT PROVIDE ANY | | | INFORMATION AS TO CURB CUTS, PEDSTRIAN | | | CROSS WALKS, ETC. | | | | | | 13) SHEET A5.01; | | | | | | 13A) STAIRWELL# 1 DOOR# 1.005 DOOR | | | SWINGS THE WRONG WAY AGAINST EGRESS. | | | NO HR RATING! | | | | | | 13B) STAIRWELL# 1 EXIT DOOR NO LISTING, | | | NO RATING! | | | | | | 13C) STAIRWWELL 2,3&4 ALL LEAD BACK INTO | | | THE GARAGE NOT THE EXIT DISCHARGE. | | | NO DOOR IDENTIFYCATION! NO RATING! | | | | | | 13D) GARARE LEVEL THE ELEVATOR LOBBY | | | DOOR NO IDENTIFACTION, NO RATING. | | | | | | 13E) TRASH REFUSE ROOM 1&2 NO DOOR | | | IDENTICATION, NO RATING | | | | | | 13F) FIRE PUMP ROOM NO RATING OF DOOR | | | | | | 13G) PARKING GARAGE TO BE CONSIDERED AN | | | ENCLOSED PARKING GARAGE PROVIDE | | | COMPLIANCE WITH 6 AIRCHANGES PER | | | HR.411.4.2. | | | | | | 13H) MAILBOXES SEE DETAIL A5.56 DETAIL | | | # 7, PROVIDE DIMENSIONS (ELE) TO COMPLY | | | WITH SIDE REACH RANGES. | | | | | | 13I) PLANS ARE NOT CLEAR IF STAIRWELL | | | 2 & 4 ARE IN THIS FIRST PHASE OR SECOND | | | PHASE. IF LOCATED IN 2ND PHASE DEAD END | | | CORRIDORS EXIST. | | | | | | 13J) GARAGE 4 HR FIRE WALL, PROVIDE 3 HR | | | FIRE RATED DOOR BETWEEN BUILDINGS, | | | INDICATE HOW DOOR WILL ACTIVATE WITH THE | | | SMOKE/ FIRE ALARM? | | | 705.1.3.1 WALL OPENINGS REQUIRED TO BE | | | PROTECTED SHALL BE PROTECTED BY APPROVED | | | LISTED AND LABELED FIRE DOORS, WINDOWS | | | AND SHUTTERS AND THEIR ACCOMPANYING | | | HARDWARE, INCLUDING ALL FRAMES, CLOSING | | | DEVICES, ANCHORAGE AND SILLS, IN | | | ACCORDANCE WITH THE REQUIREMENTS OF NFPA | | | 80, EXCEPT AS OTHERWISE SPECIFIED IN | | | THIS CODE. | | | | | | 14)DETAILS ON A5.70: | | | | | | 14A) DETAILS ON A5.70 AGAIN NO DOOR | | | RATINGS. | | | | | | 14B) DOUBLE DOORS: DOUBLE LEAF DOORS, | | | ANSI A117.1, 404.2 SHALL COMPLY WITH 32" | | | CLEAR, AT LEAST ONE OF THE ACTIVE LEAVES | | | OF DOORWAYS WITH 2 INDEPENDENTLY | | | OPERATED LEAVES SHALL COMPLY WITH | | | SECTION 404.2.3 & 404.2.4. | | | 404.2.3 32" CLEAR | | | 404.2.4 MANEUVERING CLEARENCES. | | | SEE CH108 & CH115. | | | | | | 14C) PROVIDE ADD INFO TYPE OF ROOM | | | EXAMPLE AT DOOR CH-117 OR CH-121? THESE | | | DOORS ARE ONLY A 2'-6" DOOR?ANSI A117.1 | | | 404.2.3 OPENINGS MORE THAN 24" DEEP | | | SHALL PROVIDE A 36" MINIMUM. | | | | | | 14D) AGAIN THERE ARE VARIOUS CLOSETS | | | WITH ONLY 2'-6" DOORS? | | | | | | 14E) LEASING OFFICE PROVIDE A CUT | | | SECTION THROUGH THE STAIR, ALSO INCLUDE | | | RATED CEILING OF CLOSET, ALSO A 2'-6" | | | DOOR. | | | | | | 15) SHEET A5.02: | | | | | | 15A) STAIR # 3 DETAIL A8.01 DETAIL 2 IS | | | MISSING PROVIDE WIDTH A1.21 INDICATES A | | | 54" WIDE STAIR, WHERE IS DETAIL? | | | THE SAME SITUATION COMMENT 17A) IS | | | MISSING DETAIL, BUT SECOND PHASE A8.10 | | | DETAIL# 2 INDICATES THE USE OF A | | | UNPROTECTED OPENING IN THE STAIRWELL SEE 1006.1.3.2 AND | | | 705.2.3 FOR OPENING | | | PROTECTIVES REQUIRED FOR RATED WALLS, | | | SEE COMMENTARY FOR 1006.1.3.2.SEE | | | ATTACHMENT. | | | | | | 15B) STAIRWELL 1,2,3&4 ARE MISSING THE | | | FIRE RATED WALL & DOOR CREATING THE | | | SHAFT ENCLOSURE REQUIRED IN TABLE | | | 705.1.2. | | | | | | 15C) STAIRWELL 2 & 4 APPEAR NOT TO BE IN | | | THIS PHASE, THEY WILL BE REQUIRED TO BE | | | IN THIS PHASE OR OTHERWISE DEAD END | | | CORRIDOR SITUATION WILL OCCUR.TO MAKE | | | THE STAIR TOWER WORK TO THE DEFINITION | | | OF FIRE WALL, THE STAIR TOWER WILL HAVE | | | TO BE BUILTWITH A 4HR WALL, ROOF | | | STRUCTURE INDEPENDENT OF THE OTHER | | | BUILDINGS AND DIRECT ACCESS FROM EACH OF | | | THE BUILDINGS EXIT ACCESS CORRIDORS,PLUS | | | THE REQUIRED 3 HR OPENING PROTECTIVES. | | | YOUR BUILDINGS DESIGN WAS BROUGHT TO THE | | | BUILDING OFFICIAL FOR HIS INTERPRETATION | | | | | | | | | DEF:WALL, PARTY. A FIRE WALL ON AN | | | INTERIOR LOT LINE, USED OR ADAPTED FOR | | | JOINT SERVICE BETWEEN TWO BUILDINGS. | | | | | | SELF-CLOSING. AS APPLIED TO A FIRE DOOR | | | OR OTHER OPENING, MEANS NORMALLY CLOSED | | | AND EQUIPPED WITH AN APPROVED DEVICE | | | WHICH WILL INSURE CLOSING AFTER HAVING | | | BEEN OPENED FOR USE. | | | | | | 705.1.3.1 WALL OPENINGS REQUIRED TO BE | | | PROTECTED SHALL BE PROTECTED BY APPROVED | | | LISTED AND LABELED FIRE DOORS, WINDOWS | | | AND SHUTTERS AND THEIR ACCOMPANYING | | | HARDWARE, INCLUDING ALL FRAMES, CLOSING | | | DEVICES, ANCHORAGE AND SILLS, IN | | | ACCORDANCE WITH THE REQUIREMENTS OF NFPA | | | 80, EXCEPT AS OTHERWISE SPECIFIED IN | | | THIS CODE. | | | | | | 705.1.5 OPENING PROTECTION IN STAIRWAY | | | ENCLOSURES. OPENING PROTECTIVESIN | | | STAIRWAY SHAFTS ARE LIMITED TO | | | SELF-CLOSING OR SMOKE ACTUATED, | | | AUTOMATIC-CLOSING FIRE DOOR | | | ASSEMBLIES.IF SMOKE-ACTUATED CLOSURES | | | CLOSE ONE DOOR, ALL DOORS SERVING THAT | | | STAIRWAY SHALL CLOSE. | | | | | | THE OTHER ISSUE IS A UNITY OF TITLE | | | WOULD BE REQUIRED EVEN FOR A SINGLE LOT | | | AS TO NOT BE ABLE TO SELL OFF A PORTION | | | OR BUILDING CREATING A CODE VIOLATION. | | | | | | 15D)THE MENTIONED STAIRWELLS ARE ALSO | | | MISSING THE FIRE RATED WALLS AND DOORS. | | | TABLE 705.1.2 | | | | | | 15E) THE FIRE WALL NEXT TO STAIRWELL | | | 2 & 4, PHASE H OR BLDG 2 DOES HAVE THE | | | FIRE RATED DOORS LABELED BUT ONLY AS | | | 1 HR. AGAIN SEE TABLE 705.2.1, 4HR FIRE | | | WALL /3HR OPENING PROTECTIVES. | | | THIS DOOR WILL ALSO NEED TO BE SELF | | | CLOSING AND SELF LATCHING NO INFORMATION | | | PROVIDE FOR HARDWARE. THIS DOOR AS WELL | | | AS OTHER FIRE RATED DOORS WILL REQUIRE | | | DOOR SILLS SEE 705.1.3.1 AND NFPA 80. | | | | | | 15F) ENTRY DOORS TO THE INDIVIDUAL UNITS | | | ALSO WILL REQUIRE IDENTICATION AND FIRE | | | RATING. | | | | | | 15G) ROOM NOT IDENTIFIED DOOR# 1.102? | | | | | | 16) SHEET A5.71: | | | | | | 16A) DOUBLE LEAF DOORS CH203 & 208 | | | SEECOMMENT 14B. | | | | | | 16B) VARIOUS ROOMS NOT MARKED EXAMPLE | | | DOOR CH-211, ALSO A DOORS 2'-6"? | | | | | | 17) SHEET A5.03 HAS THE SAME ISSUES AS | | | SHEET A5.02. | | | | | | 17A) STAIR TOWER# 3, SAME COMMENT AS 15A | | | A NEW PAGE AND SECTION PROVIDED A8.07 | | | DETAIL# 2 MISSING. PLEASE PROVIDE. | | | REQUIRES OPENING PROTECTIVES. | | | | | | 18) SHEET A5.10: | | | | | | 18A) TRASH ROOM DETAIL 1&2 OF A8.20 THE | | | DETAIL IS MISSING THE ENCLOSURE TO THE | | | BOTTOM OF THE CHUTE ENCLOSURE.705.2.4.2 | | | ALL OPENINGS INTO THE SHAFT ENCLOSURE, | | | INCLUDING THOSE FROM ACCESS ROOMS AND | | | TERMINATION ROOMS, SHALL BE PROTECTED IN ACCORDANCE | | | WITH TABLE 705.1.2.SUCH | | | OPENING PROTECTIVES SHALL BE | | | SELF-CLOSING OR AUTOMATIC-CLOSING UPON | | | DETECTION OF SMOKE, EXCEPT THAT THE | | | OPENING PROTECTIVE BETWEEN THE SHAFT AND | | | THE TERMINATION ROOM MAY BE CLOSED BY A HEAT-ACTIVATED | | | DEVICE. | | | | | | 18B) THE TERMINATION ROOM DOOR NO | | | INFORMATION ON RATING? | | | | | | 18C) THERE IS NO INFORMATION ON THE | | | COMBUSTIBLITY OF THE TRASH CHUTE NOR | | | ON AUTOMAICALLY CLOSING OPENINGS | | | 705.2.4.2. | | | | | | 18D) REFRENCES DETAIL# 22 SHEET A7.10 | | | PROVIDE THE UL APPROVAL NUMBER WHERE THE | | | | | | 2X 6 PT BLOCKING IS PART OF A 2 HR RATED | | | WALL WHEN USED IN THIS APPLICATION, NOT | | | COVERED BY ANY DRYWALL?TABLE 705.1.2. | | | 2 HR RATING. | | | | | | 18E)705.2.4.6 AUTOMATIC SPRINKLERS. AN | | | APPROVED AUTOMATIC SPRINKLER SYSTEM | | | SHALL BE INSTALLED AT THE TOP AND AT | | | ALTERNATE FLOOR LEVELS IN REFUSE AND | | | LAUNDRY CHUTES AND IN THE TERMINATION | | | AND INCINERATOR ROOMS. | | | | | | 19) SHEET A5.11 IS FOR THE FIRST FLOOR | | | ABOVE THE GARAGE FLOOR: | | | | | | 19A)THIS SHEET DOES NOT INDICATE THAT IS | | | COMMON FOR FLOORS 2-5. | | | | | | 19B) THE STAIR TOWERS ARE NOT LABELED. | | | | | | 19C) STAIR DETAIL A8.10 DETAIL# 2 | | | INDICATES OPENINGS IN STAIR TOWER SEE | | | COMMENT 15A FOR REQUIRED OPENING | | | PROTECTIVES FOR RATED WALLS. | | | | | | 20)SHEET A5.20 & A5.21. | | | BUILDING# 3 OR PHASES I,J AND K WILL | | | HAVE THE SAME PROBLEMS MENTIONED IN | | | BUILDING# 1&2 AS FAR AS PHASING, EGRESS, FIREWALLS, | | | FIREDOORS, STAIR TOWERS, | | | DOORS NOT LABELED NOR FIRE RATINGS AND | | | REFUSE CHUTES. | | | | | | 21) SHEET A5.22 | | | 21A) THIS SHEET COMMON FOR FLOORS 2-5, | | | LOOKS LIKE THE WRONG LAYER WAS TURNED ON | | | AND NOT COMPLETED.SEE DETAIL 3 SHEET | | | A7.03 INDICATES UNITS PLEASE CORRECT. | | | WITH NO DETAILS FURTHER COMMENTS MAY | | | APEAR ON FUTURE REVIEWS. | | | | | | 22) VARIOUS SHEETS ON BUILD 1,2 & 3 | | | INDICATE A DETAIL SECTION# 23 SHEET | | | A7.10. | | | | | | 22A) THIS SECTION INDICATES METAL | | | TRUSSES TO BE USED BUT NO INFORMATION | | | AS TO THE ROOF DECKING MATERIAL TO BE | | | USED? TYPE IV UNPROTECTED- NC | | | TYPE IV 1HR- IHR PROTECTED | | | | | | 22B) PROVIDE A DETAIL INDICATING ACCESS | | | TO ATTIC AREA. | | | | | | 22C) THIS SAME SECTION INDICATES USE OF | | | FOAM TRIM ON THE EXTERIOR OF THE | | | BUILDING ABOVE 40'.1404.1.1 | | | ARCHITECTURAL TRIM ON BUILDINGS OF TYPE | | | I, II AND IV CONSTRUCTION NOT MORE THAN | | | THREE STORIES OR 40 FT (12.2 M) HIGH MAY | | | BE OFTYPE VI CONSTRUCTION, AND MAY BE | | | OF TYPE VI CONSTRUCTION ON ALL BUILDINGS | | | OF TYPE III, V AND VI CONSTRUCTION. | | | TRIM SHALL BE SECURED TO THE WALL WITH | | | METAL OR OTHER APPROVED BRACKETS OR | | | FASTENERS.WHEN ARCHITECTURAL TRIM IS | | | LOCATED ALONG THE TOP OF EXTERIOR WALLS, | | | IT SHALL BE COMPLETELY BACKED BY THE | | | EXTERIOR WALL AND SHALL NOT EXTEND OVER | | | THE TOP OF EXTERIOR WALLS. | | | | | | 23) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 24) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) OPARATABLE WINDOWS | | | B) FIXED WINDOWS | | | C) MULLION | | | D) EXTERIOR DOORS SOLID | | | E) EXTERIOR DOORS GLAZED | | | F) EXTERIOR DOORS LOUVERED | | | G) STORM SHUTTERS | | | H) EXTERIOR RAILINGS | | | I) LOUVERS | | | J) TRUSS ANCHORS | | | K) ROOFING ASSEMBLIES | | | L) EFIS SYSTEMS | | | | | | 25) AN INTERPRETATION FROM THE BUILDING | | | OFFICIAL ON STORM SHUTTERS THAT ARE USED | | | ON LARGE PROJECTS: | | | QUESTION# 13) RECOGNIZING SUCH CONCERNS | | | AS ABSENTEE OWNERS, OR CASES WHERE | | | LONGER TIME AND EFFORT IS NECESSARY TO | | | SECURE SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDINGS, WHAT MEASURES ARE BEING | | | RECOMMENDED OR IMPLEMENTED TO ENSURE | | | THAT COMPLETE INSTALLATION OR SECURING | | | IS DONE SUFFICIENTLY IN ADVANCE OF THE | | | HURRICANE EVENT? | | | | | | IN MATTERS FLORIDA BUILDING CODE, 2004 | | | EDITION, PROVIDES THE ABILITY FOR THE | | | BUILDING OFFICIAL TO IMPLEMENT | | | REQUIREMENTS FOR ENSURING STABILITY, | | | STRENGTH, AND PROPER OPERATION OF | | | EXISTING BUILDINGS. | | | | | | IN ORDER TO ASSURE THE SECURING OF | | | SHUTTERS ON LARGE OR MULTI-STORY | | | BUILDING, OR MULTIPLE BUILDINGS ON THE | | | SAME PROPERTY, PRE-STORM PREPARATION | | | PLANS MUST BE SUBMITTED BY THE PROPERTY | | | OWNERS OR MANAGING AGENTS FOR REVIEW BY | | | THE CONSTRUCTION SERVICES DEPARTMENT. | | | ANY SUCH PLAN SHALL INCLUDE, AT A | | | MINIMUM, ON-SITE LOCATION OF SHUTTERS, | | | PARTY RESPONSIBLE FOR SECURING THE | | | SHUTTERS (SAID PARTIES MUST BE LOCATED | | | WITHIN PALM BEACH COUNTY), TOTAL NUMBER | | | OF OPENINGS TO BE PROTECTED AND TOTAL | | | TIME REQUIRED TO SECURE ALL OPENINGS. | | | PROTECTION OF OPENINGS SHALL BE | | | ACCOMPLISHED WITHIN TWELVE (12) HOURS OR | | | LESS OF THE OFFICIAL NOTIFICATION BY THE | | | NATIONAL WEATHER SERVICE OF A HURRICANE | | | WATCH. | | | | | | PROVISIONS IN THE BUILDING CODES (AND | | | THIS STANDARD) ARE NOT INTENDED TO | | | PROHIBIT THE USE OF ALTERNATIVE | | | MATERIALS AND METHODS, AND ALLOW THE | | | BUILDING OFFICIAL TO REVIEW AND APPROVE | | | ANY ALTERNATE DEEMED EQUIVALENT IN | | | QUALITY, STRENGTH, EFFECTIVENESS, FIRE | | | RESISTANCE, DURABILITY AND SAFETY | | | PRESCRIBED BY CODE. BASED UPON THIS CODE PROVISION, | | | ACCEPTANCE OF ALTERNATE | | | MATERIALS AND METHODS MAY BE APPROVED ON | | | A CASE-BY-CASE BASIS AND SHALL REQUIRE | | | SUFFICIENT EVIDENCE OR PROOF TO | | | SUBSTANTIATE ANY CLAIM MADE REGARDING | | | THE ALTERNATE. | | | | | | QUESTION# 14) ARE REMOVABLE STORM PANELS APPROPRIATE | | | FOR USE ON VERY LARGE, MID | | | OR HIGH-RISE STRUCTURES? | | | | | | NO, EXCEPT ON THE GROUND FLOOR. ON | | | COMMERCIAL AND MULTI-UNIT RESIDENTIAL | | | STRUCTURES, ABOVE THE FIRST LEVEL, | | | IMPACT RESISTANT GLAZING OR PERMANENTLY | | | AFFIXED PROTECTIVE DEVICES SHALL BE | | | INSTALLED. PERMANENTLY AFFIXED | | | PROTECTIVE DEVICES SHALL REQUIRE THE | | | WRITTEN APPROVAL OF THE BUILDING | | | OFFICIAL. | | | | | | 26) PROVIDE STORM PANEL INFORMATION WITH INSTALLATION | | | SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED | | | FOR ALL NON-IMPACT GLAZING. | | | FBC 1606.1.4. | | | | | | 27) FL BLD CODE 2001 SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | 28) 3003.6.1 VENTS. HOISTWAYS OF ELEVA- | | | TORS SERVING MORE THAN 3 FLOORS SHALL BE | | | PROVIDED WITH MEANS OF VENTING SMOKE AND | | | HOT GASES TO THE OUTER AIR IN CASE OF | | | FIRE. | | | | | | 29)3003.6.2 VENTS SHALL BE LOCATED BELOW | | | THE FLOOR OR FLOORS AT THE TOP OF THE | | | HOISTWAY, AND SHALL BE EITHER DIR- ECTLY | | | TO THE OUTER AIR OR THROUGH NON- | | | COMBUSTIBLE DUCTS TO THE OUTER AIR. | | | | | | 30) 3003.6.3 THE AREA OF THE VENTS SHALL | | | BE NOT LESS THAN 3 SQ FT FOR EACH | | | ELEVATOR CAR, WHICHEVER IS GREATER. | | | | | | 31)SHEET S4.00 INDICATES THE ROOF ZONES | | | FOR A SIMPLE RECTANGLE. PROVIDE A | | | DETAILED ZONE MAP AS IT RELATES TO THIS | | | BUILDING INCLUDING PENTHOUSES WITH THE | | | APPROPRIATE PRESSURES. | | | | | | 32) A9.03 WINDOW BUCK DETAIL CORRECT: | | | 1707.4.4.2 TAPERED BUCKS: | | | SHALL EXTEND BEYOND THE INTERIOR FACE | | | OF THE WINDOW OR DOOR FRAME SUCH THAT | | | FULL SUPPORT OF THE FRAME IS SUPPORTED. | | | | | | 33) S3.51-S3.54 | | | 1511.7 ROOF MOUNTED MECHANICAL UNITS | | | SHALL BE MOUNTED ON CURBS RAISED A | | | MINIMUM OF 8 INCHES ABOVE THE ROOF SUR- | | | FACE, OR WHERE ROOFING MATERIALS EXTEND | | | BENEATH THE UNIT, ON RAISED EQUIPMENT | | | SUPPORTS PROVIDING A MINIMUM CLEARENCE | | | HEIGHT IN ACCORDANCE WITH TABLE 1511.7. | | | | | | 34) 1503.4.4 PROTECTION AGAINST DECAY & | | | TERMITES. CONDENSATE LINES & ROOF DOWN | | | SPOUTS SHALL DISCHARGE AT LEAST 1 FT. | | | AWAY FROM THE STRUCTURE SIDEWALL, | | | WHETHER BY UNDERGROUND PIPING, TAIL EX- | | | TENSIONS, OR SPLASH BLOCKS. | | | | | | 35) ELECTRICAL SHEETS MISSING SMOKE | | | ALARMS IN BEDROOMS.905.1.1A FIRE ALARM | | | SYSTEM IN ACCORDANCE WITH NFPA 72SHALL | | | BE INSTALLED. | | | | | | | | | A COMPLETE REVIEW CAN NOT BE COMPLETED | | | AT THIS TIME. DEPENDING ON THE RESPONCES | | | FROM THIS REVIEW ADDITIONAL COMMENTS MAY | | | APPEAR ON THE NEXT REVIEW. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-21 |
Time |
12:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-16 |
Time |
13:07 |
Sent To |
|
|
| Notes |
| 2007-09-21 12:51:22 | 2007-09-21 12:51:22 | | | | | | ** DENIED 3RD REVIEW** | | | | | | BUILDING #1 | | | | | | ** PLEASE SEE THERE ARE SOME ITEMS FROM PREVIOUS REVIEW | | | WHICH ARE STILL IN NEED OF ADDRESSING. PLEASE ALSO SEE | | | THERE ARE SEVERAL NEW COMMENTS BASED ON REVISED | | | PLANS/PLANS AND DOCUMENTS NOW SUBMITTED. PLEASE SEE | | | THERE ARE SEVERAL COMMENTS FROM THE TWO PREVIOUS | | | REVIEWS WHICH STILL REMAIN. PLEASE SEE FINAL COMMENT | | | WITH RESPECT TO FLORIDA STATUTES 553.80(2)(B) WITH | | | RESPECT TO REPEAT COMMENTS FOR CODE COMPLIANCE. | | | | | | ***THE PREVIOUS REVIEW MENTIONED THERE MAY BE NEW | | | COMMENTS AS THERE WAS A SUBSTANTIAL AMOUNT OF MISSING | | | INFORMATION ON PLANS AND DOCUMENTS ETC. | | | THE REVIEWS CAN ONLY BE DONE ON THE PLANS AND DOCUMENTS | | | SUBMITTED. WHEN INFORMATION ON PLANS IS NOT COMPLETE OR | | | MISSING A COMPLETE REVIEW FOR CODE COMPLIANCE IS NOT | | | POSSIBLE. THEREFORE THERE ARE NEW COMMENTS. | | | | | | ** SOME ITEMS COULD HAVE BEEN RED-LINED, HOWEVER MOST | | | OF THESE ARE IN NEED OF ADDRESSING AT THIS TIME. | | | | | | 1) NOTE:PLEASE SEE THE PLANS DO NOT INDICATE FIXTURE | | | DESIGNATIONS FOR ALL LIGHTING. | | | PLEASE SEE THERE ARE SEVERAL AREAS INCLUDING FIRST | | | FLOOR AND OTHER FLOORS WHERE FIXTURES ARE STILL MISSING | | | DESIGNATIONS. | | | PLEASE SEE THE FIXTURE LEGEND COULD NOT BE COORDINATED | | | WITH THESE AT THIS TIME. | | | PLEASE SEE COMMON AREAS WHICH THE LEGEND ON ELECTRICAL | | | PLANS COULD NOT BE FOUND. | | | PLEASE SEE THE INFORMATION ON THE INPUT DATA REPORT FOR | | | EXTERIOR LIGHTING ALSO NEEDS TO CORRELATE WITH PLANS. | | | THE LIGHTING, TYPES, NUMBER OF FIXTURES, ETC IS NOT | | | STATED ON THE IDR AS ON PLANS. | | | PLEASE SEE THE ENERGY CALCULATIONS AS SUBMITTED AS THE | | | INPUT DATA REPORT DOES NOT CORRELATE WITH ALL | | | ELECTRICAL LIGHTING FOR INTERIOR LIGHTING WHICH IS ON | | | PLANS. | | | | | | PLEASE SEE THE ENERGY CALCULATIONS/INPUT DATA REPORT IS | | | MISSING A SUBSTANTIAL AMOUNT OF LIGHTING WHICH IS ON | | | THE PLANS. | | | PLEASE SEE FOR EXAMPLE ONE ROOM IN THE CLUBHOUSE: | | | *FITNESS CENTER* WHICH LISTS ONE FIXTURE BEING | | | FLUORESCENT AND 750WATTS ON THE INPUT DATA REPORT, YET | | | HOW IS THIS POSSIBLE WHEN THE FIXTURE TYPES ON PLANS | | | ARE INCANDESCENT, FLUORESCENT ETC, THERE A SEVERAL | | | FIXTURES AND NOT JUST ONE AND THE TOTAL WATTAGE OF THE | | | LIGHTING FIXTURES BASED ON THE FIXTURE LEGEND PROVIDED | | | FOR THE CLUBHOUSE FAR EXCEEDS THE 750WATTS AS ENTERED? | | | | | | THIS IS THE SAME OF ALMOST ALL LOCATIONS NOT ONLY THE | | | CLUBHOUSE. THERE ARE ACTUALLY HUNDREDS OF FIXTURES ON | | | THE PLANS WHICH ARE NOT INCLUDED IN THE ENERGY | | | CALCULATIONS. | | | THE FIXTURE TYPES DO NOT CORRELATE. | | | THE WATTAGE DOES NOT CORRELATE | | | THE NUMBER OF FIXTURES DOES NOT CORRELATE. | | | THE TOTAL ENERGY CONSUMPTION OF LIGHTING ENTERED IN THE | | | INPUT DATA REPORT IS FAR LESS THAN THE LIGHTING AND | | | CONSUMPTION OF ENERGY ON PLANS. | | | PLEASE KNOW THESE ARE MINIMUM REQUIREMENTS FOR ENERGY | | | AND ARE FEDERAL AND STATE REQUIRED. | | | 13-415.0, 415.1.ABCD, 415.1.A, 415.2, THERE ARE TOO | | | NUMEROUS CODE SECTIONS TO LIST, PLEASE SEE CHAPTER 13 | | | OF THE 2001 FBC. | | | | | | 2) NOTE: PLEASE SEE ONLY ONE COPY OF THE ENERGY | | | CALCULATIONS (1.22 VERSION) SUBMITTED ACTUALLY CONTAINS | | | AN ORIGINAL SIGNATURE AND DATE. PLEASE SEE THAT TWO | | | SETS CONTAIN A RAISED SEAL OVER A PHOTO-COPIED | | | SIGNATURE AND THE THIRD DOES NOT CONTAIN A RAISED | | | SEALED OR ORIGINAL SIGNATURE. | | | **PLEASE KNOW THIS COMMENT HAS BEEN MADE TO THIS DESIGN | | | PROFESSIONAL ON SEVERAL PROJECTS SUBMITTED TO THIS | | | JURISDICTION. THIS COMMENT WILL ALSO BE UNDER BUILDINGS | | | 1 AND 3. | | | PLEASE KNOW THIS OFFICE IS RETAINING ALL COPIES | | | SUBMITTED FOR POSSIBLE SUBMISSION TO THE FLORIDA BOARD | | | OF ENGINEERS NOT ONLY FOR THE FACT THIS OFFICE HAS | | | REPEATEDLY MADE THIS SAME COMMENT ON NUMEROUS PROJECTS | | | TO THE SAME DESIGNER, BUT ALSO FOR INFORMATION ON PLANS | | | AND ENERGY CALCULATIONS NOT COORDINATING. | | | THIS IS A FLORIDA STATUTE AND IS ALSO STATED IN THE | | | FLORIDA ADMINISTRATIVE CODE.FS 471.025, FAC | | | 61G15-23.002, FBC 103.1. | | | ** WHEN PLANS WERE RE-SUBMITTED THIS REVIEWER NOTICED | | | THE INCORRECT VERSION ON THE CALCULATIONS SUBMITTED AND | | | NEW CALCULATIONS WITH THE CORRECT VERSION WAS SENT VIA | | | FED-EX. PLEASE SEE THAT THE ONES DONE UNDER THE 2004 | | | FBC WERE ALSO NOT SIGNED, DATED AND SEALED CORRECTLY | | | AND AS REQUIRED BY THE FLORIDA STATUTES. THIS SHOWS | | | SAME NON-COMPLIANCE ON MULTIPLE SETS OF DOCUMENTS. ** | | | PLEASE BE SURE TO GO OVER ALL AND CORRECT. | | | | | | 3) NOTE: PLEASE SEE INFORMATION FOR SITE LIGHTING POLES | | | DO NOT CONTAIN THE MINIMUM WIND LOAD INFORMATION. | | | PLEASE KNOW IF THIS INFORMATION IS NOT COMPLETE UNDER | | | BASE PLANS, THESE WILL BE REQUIRED TO BE UNDER SEPARATE | | | PERMITS, PLANS AND FEES. | | | PLEASE KNOW HOWEVER THE LIGHTING INFORMATION AS NOTED | | | ABOVE IN NOTE #1 FOR THE ENERGY CALCULATIONS WILL STILL | | | NEED TO BE CORRECTED. | | | PLEASE IDENTIFY THE CIRCUITS AS SHOWN ON PLANS TO WHICH | | | BUILDING HOUSE PANEL THEY TERMINATE. PLEASE SEE THIS IS | | | DONE FOR THE SITE LIGHTING CIRCUITS FOR BUILDING #2 BUT | | | NOT THE OTHERS. | | | | | | 4) NOTE: PLEASE SEE THE SYMBOL LEGEND STILL INDICATES | | | *SMOKE DETECTORS*. THIS COULD BE REDLINED IF AND WHEN | | | ALL OTHER COMMENTS AS ADDRESSED. PLEASE KNOW IF THERE | | | ARE ANY COMMENTS HOWEVER WHICH MAY AFFECT THE SAME | | | SHEET(S), PLEASE CORRECT AT THIS TIME. E16.01 THIS | | | COULD BE REDLINED ON THIS SHEET IF NOT OTHER CHANGES IS | | | MADE. | | | ** THIS IS ALSO SHOWN ON LEGENDS ON OTHER SHEETS. | | | | | | 5) NOTE: PLEASE INDICATE ALL CIRCUITING ON PLANS. | | | PLEASE SEE THIS WAS NOTED ON PREVIOUS REVIEW AND | | | SPECIFICALLY NOTED TO SEE 700.12E FOR CIRCUITING OF | | | EMERGENCY AND EXIT LIGHTS. | | | PLEASE SEE THERE IS EMERGENCY AND EXIT LIGHTING | | | FIXTURES WHICH ARE STILL MISSING CIRCUITING. ( | | | CLUBHOUSE) | | | FBC 104.1.2 (2001) ADMIN SECTION FOR ADDITIONAL | | | INFORMATION AND COORDINATION OF PLANS. | | | ** THIS WAS IN PREVIOUS REVIEWS NOTES #6, #7, AND NOTE | | | #30 AT A MINIMUM. SPECIFICALLY 700.12E WAS NOTED. | | | | | | 6) NOTE: PLEASE SEE DISHWASHER AND DISPOSAL WHICH IS | | | BEING SHOWN WITH A J-BOX. ARE THESE ITEMS GOING TO BE | | | HARDWIRED? | | | PLEASE SEE 422.30, 422.31 FOR REQUIRED DISCONNECTING | | | MEANS. | | | ARE THESE NOT CORD AND PLUG TYPE APPLIANCES WHICH WOULD | | | PLUG IN? | | | | | | 7) NOTE: PLEASE CLARIFY WHERE THE ROOM AND AREA | | | DESIGNATIONS ARE ON PLANS. EXAMPLE: BEDROOM #1, DINING | | | ROOM, LIVING ROOM ETC. | | | PLEASE KNOW THE PREVIOUS REVIEW REQUESTED FOR ALL | | | CIRCUITING TO BE COMPLETED ON PLANS AND TO CORRELATE | | | WITH PANEL SCHEDULES HOWEVER AS NOTED IN NOTE #5 ABOVE | | | THIS IS STILL NEEDED IN MANY LOCATIONS. | | | PLEASE SEE SHEET E16.05, WHICH INDICATES CIRCUITS CB32 | | | FOR ELEVATOR PIT LIGHTS AND RECEPTACLES AND INDICATES | | | CB-30 FOR *H*. | | | THE *H* IS NOT KNOWN AND BOTH CIRCUITS ON PANEL | | | SCHEDULE CB ARE SHOWN A BLANK/SPARES. | | | AS THESE CIRCUITS ARE NOT INDICATED WE CAN NOT | | | DETERMINE MINIMUM COMPLIANCE WITH 620.22-620.25 PLEASE | | | SEE OTHER ELEVATOR EQUIPMENT ROOMS AND AREAS WHICH SEEM | | | TO INDICATE LIGHTING HOWEVER THE LIGHTING IS SHOWN | | | CIRCUITED ON THE SAME LIGHTING AS GARAGE AND/OR OTHER | | | COMMON AREAS. | | | PLEASE VERIFY ALL ON PLANS, AND CORRELATE WITH PANEL | | | SCHEDULES. THIS IS NOT ALL LOCATIONS. | | | ** THIS WAS NOTED ON PREVIOUS REVIEWS NOTE # 9. | | | | | | 8) NOTE: PLEASE SEE THE MISSING LIGHTING OUTSIDE FIRE | | | PUMP ROOM AND STAIR AREA. PLEASE SEE MISSING | | | PHOTO-METRICS ETC. | | | PLEASE SEE MISSING PHOTO-METRICS FOR CLUBHOUSE STAIR | | | AREA UNDER NORMAL AND EMERGENCY. | | | PLEASE SEE THE LEVEL OF LIGHTING OUTSIDE MAIN | | | ELECTRICAL ROOM FOR BOTH CONDITIONS OF NORMAL AND | | | EMERGENCY DOES NOT SEEM TO MEET THE MINIMUM LEVELS | | | REQUIRED. PLEASE SEE THE NORMAL LEVEL IS SHOWN ONLY AS | | | 6.38 AND LESS THAN 1FT CANDLES UNDER EMERGENCY? | | | NFPA-101 7.8.1.3, 7.9.2.2. | | | PLEASE KNOW AS THERE ARE NO LIGHTING FIXTURES, | | | CIRCUITING ETC SHOWN FOR SOME AREAS, PLEASE COMPLETE. | | | PLEASE ALSO BE SURE TO GO OVER ALL EGRESS PATHS | | | ESPECIALLY STAIR AREAS. THERE ARE OTHER AREAS ALSO. | | | | | | PLEASE ILL BE REQUIRED TO BE BATTERY BACK UP. THIS IS | | | SHOWN AS A *J* FIXTURE. S NO FIXTURE LEGEND WAS | | | SUBMITTED THIS CAN NOT BE VERIFIED AT THIS TIME. PLEASE | | | ALSO SEE ARE OUT SIDE ELEVATOR EQUIPMENT AREA AND MAIN | | | ELECTRICAL ROOM WILL ALSO REQUIRE AN EMERGENCY BATTERY | | | BACK UP LIGHTING FIXTURE OF SOME KIND. | | | NEC 700.12E, 700.16, LS-101 7.8, 7.9 | | | ** THIS WAS NOTE ON PREVIOUS REVIEWS NOTE #6 | | | | | | 9) NOTE: PLEASE SEE THE PREVIOUS NOTES QUESTIONED THE | | | EGRESS PATH FROM CLUBHOUSE INTO THE GARAGE WHICH IS | | | MAIL CENTER HALL AS THE EXIT LIGHT AND DOOR ON | | | CLUBHOUSE PLANS SHOWS THE EGRESS INTO THIS AREA AND THE | | | MAIL CENTER HALL AREA INDICATES EXIT LIGHTS WITH | | | DIRECTIONAL INTO THE CLUBHOUSE??? | | | THERE ARE SEVERAL OTHER LOCATIONS WHERE EXIT LIGHTS ARE | | | IN QUESTION BASED ON THE LAYOUTS SHOWN ON THE | | | ELECTRICAL PLANS. | | | SEE MAIL CENTER AREA ADJACENT TO PARKING AREA WHICH | | | DOES NOT INDICATE ANY EXIT LIGHT FIXTURES DIRECTING AN | | | OCCUPANT TO THE EXIT. | | | THIS HAS BEEN GONE OVER WITH THE BUILDING PLAN REVIEWER | | | AND COMMENTS WILL BE NOTED ON THESE LOCATIONS. THE LIFE | | | SAFETY PLAN ALSO INDICATES WHAT IS BEING SHOWN AS | | | EGRESS PATHS THROUGH PARKING SPACES ETC. | | | PLEASE SEE COMMENTS FROM BUILDING REVIEWER, AND FIRE | | | MARSHAL. | | | PLEASE SEE CHAPTER 10 OF THE FBC AND CHAPTER 7 OF THE | | | LIFE SAFETY CODE. | | | THE EGRESS PATHS ARE NOT IN REVIEW OF THE ELECTRICAL | | | REVIEWER HOWEVER AS MANY OF THE EXIT AND EMERGENCY | | | LIGHTING ARE IN QUESTION AND THIS DIRECTLY AFFECTS THE | | | ELECTRICAL PLANS THIS IS BEING NOTED FOR INFORMATION AT | | | THIS TIME. | | | | | | 10) NOTE: PLEASE SEE PLANS ARE NOT COMPLETE WITH WIND | | | LOAD INFORMATION FOR SITE LIGHTING. | | | IF NOT INCLUDED IN THE PLANS, THEN THESE WILL ALL BE | | | REQUIRED TO BE UNDER SEPARATE PERMITS. | | | ** THIS WAS NOTED ON NOTE #7 ON PREVIOUS REVIEWS. | | | | | | 11) NOTE: PLEASE CLARIFY THE FIRE PUMP AND INFORMATION | | | AS REQUESTED ON THE PREVIOUS REVIEWS. | | | PLEASE SEE NO INFORMATION WAS SUBMITTED WITH RESPECT TO | | | THE MINIMUM FUEL REQUIREMENTS AND SIZE OF TANK. PLEASE | | | SEE NO TIMES AT 100% RUNNING IS SHOWN. | | | PLEASE SEE NFPA-20 9.6.2.2 AND SEE COMMENTS FROM FIRE | | | MARSHAL. | | | PLEASE SEE THE FUEL NOTE WHICH IS ON SHEET FP13.09 #3, | | | DOES NOT CONTAIN THE TEXT FOR CODE. | | | PLEASE SEE THE MINIMUM ON THE BASE BUILDING IS REQUIRED | | | AT THIS TIME. | | | PLEASE SEE THE PREVIOUS NOTES WHICH REQUESTED THIS SAME | | | INFORMATION. | | | PLEASE SEE THE FP SHEETS INDICATE A DIESEL FIRE PUMP, | | | YET THE SUBMITTALS WHICH WERE SUBMITTED WITH PLANS | | | INDICATE AN ELECTRICAL FIRE PUMP. | | | PLEASE SUBMIT THE ACTUAL DOCUMENTATION AND CORRELATE | | | WITH PLANS. | | | 110.3, 90.7, NFPA-70 695, NFPA-20 2003 | | | **THIS WAS NOTED ON TWO PREVIOUS REVIEWS ON NOTE #10. | | | | | | 12) NOTE: PLEASE LABEL ALL MAINS, MAIN 1 OF ? , 2OF ? | | | /SERVICE #1 MAIN #1, SERVICE #2 MAIN #1, SERVICE #3 | | | MAIN 1 ETC. | | | PLEASE BE SURE TO CONTACT THIS OFFICE WITH RESPECT TO | | | PLAGUE DIRECTLY LABELING AND INFORMATION. THIS CAN BE | | | GONE OVER WITH THE CHIEF ELECTRICAL INSPECTOR ALSO | | | BEFORE PLAGUES ARE INSTALLED. | | | PLANS SHOW 7 MAINS AT THIS TIME. | | | PLEASE SEE 230.2, (E) | | | | | | 13) NOTE: PLEASE SEE BUILDING REVIEW COMMENTS WITH | | | RESPECT TO ELEVATOR PLATFORMS WHICH MAY AFFECT | | | ELECTRICAL PLANS AND LAYOUTS. | | | | | | 14) NOTE: PLEASE SEE DOOR SWING FOR METER/ELECTRICAL | | | ROOM 1C2, NEEDS TO SWING OUT. | | | 110.26 | | | | | | 15) NOTE: PLEASE SEE THE PREVIOUS REVIEW NOTES GAVE | | | NOTICE TO FS 553.80(2)(B) WITH RESPECT TO REPEAT | | | COMMENTS FOR CODE COMPLIANCE. | | | PLEASE KNOW AT THIS TIME ONE SET OF PLANS MAY BE | | | RETAINED BY THIS OFFICE FOR PEER REVIEW AS THERE ARE | | | SOME CODE SECTIONS WHICH HAVE STILL NOT BEEN COMPLIED | | | WITH. | | | PLEASE KNOW ONE GONE OVER THIS FEE MAY BE ASSESSED | | | WHICH IS REQUIRED UNDER THE FLORIDA STATUTES. THIS FEE | | | IS NOT TO THE CONTRACTOR/OWNER OR DEVELOPER THIS IS TO | | | THE DESIGN PROFESSIONAL(S). | | | ** PLEASE BE SURE TO GO OVER COMMENTS. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | | | | *** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS | | | OR COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. | | | IF THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY | | | WAY, NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, | | | PLEASE DO NOT HESITATE IN CONTACTING THIS OFFICE AND | | | THIS REVIEWER. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-09-20 16:32:34 | 2007-09-20 16:32:34 | | | | | | REVIEW COMMENCED | | 2007-09-16 13:07:43 | 2007-09-16 13:07:43 | | | | | | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-01-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-01-01 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-01-01 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2007-01-01 13:54:45 | | | | **** UNSAT2ND REVIEW ******** | | | | | | COURTNEY LAKES BUILDING #1 | | | N. CONGRESS. | | | | | | ** PLEASE SEE MANY OF THE SAME COMMENTS FROM THE | | | PREVIOUS REVIEW STILL NEED TO BE ADDRESSED. | | | | | | ** PLEASE SEE AS THREE SEPARATE BUILDING PERMITS AND | | | PLANS ARE NOW SEPARATED FOR EACH, PLEASE ALSO SEE NEW | | | COMMENTS BASED ONE THE PLANS NOW SUBMITTED INTO EACH | | | SET. | | | PLEASE SEE THE COMMENTS ON BUILDING ONE ARE DIFFERENT | | | IN MANY ASPECTS BASED ON THE DESIGN ALONE AND PROPOSED | | | PHASES OF PROJECT. | | | | | | ** PLEASE ALSO SEE THERE ARE SOME NEW NOTES BASED ON | | | PLANS SUBMITTED. | | | | | | ** PLEASE SEE BELOW ARE SOME OF THE NOTES FROM THE | | | PREVIOUS REVIEW ARE BEING NOTED IF ADDRESSED OR NOT BY | | | A "NO, OK, NO/OK, N/A OR SEE NEW ". | | | 1) NO WILL HAVE FURTHER EXPLANATION IN AN ATTEMPT TO | | | BETTER EXPLAIN COMMENT MADE. | | | 2) OK, WILL HAVE PREVIOUS NOTE REMOVED. | | | 3) NO/OK, MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL. THIS WILL ALSO BE FOLLOWED | | | BY FURTHER EXPLANATION OF PREVIOUS NOTE. | | | 4) N/A, THIS MEANS THE COMMENT NO LONGER APPLIES TO | | | THIS BUILDING AND PREVIOUS NOTE IS REMOVED. | | | | | | ** PLEASE SEE ALL NEW NOTES WILL BE NOTED AT THE END OF | | | PREVIOUS REVIEW COMMENTS AND WILL BE INDICATED WITH | | | **** NEW NOTES**. | | | | | | | | | 1) NOTE: NO, PLEASE SEE THE SETS ARE NOT BOUND TOGETHER | | | IN A FASHION TO SECURE ALL SHEETS. | | | PLEASE SEE THE PLANS SUBMITTED FOR BUILDING #1 ARE ALL | | | FALLING APART AND WERE NOT SECURELY PUT TOGETHER. | | | PLEASE SEE THE STAPLES BEING USED DO NOT GO THROUGH ALL | | | SHEETS. | | | PLEASE SEE SOME SETS WERE ALREADY COMING APART BEFORE | | | THEY WERE OPENED FOR REVIEW. PLEASE SEE THIS IS | | | REQUIRED FOR ALL SETS AND FOR ALL PLANS. | | | PLEASE OBTAIN A METHOD TO SECURE AND BOUND PLANS | | | TOGETHER. | | | IF PLANS COME BACK IN THE SAME FASHION, THIS OFFICE | | | WILL CONTACT THE CONTRACTOR TO COME IN AND PICK UP | | | PLANS TO BE CORRECTED BEFORE PROCESSING AND BEFORE | | | REVIEW WILL TAKE PLACE. | | | THE STAPLES IN SOME HAVE ALREADY COME COMPLETELY OUT. | | | THIS COMMENT IS FOR ALL WHETHER OR NOT COMMENT IS MADE | | | FOR OTHER BUILDINGS OR BY OTHER TRADES. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SUBMIT COMPLETED PLANS BOUND TOGETHER IN AN | | | APPROPRIATE FASHION. PLEASE SEE ALL SHEETS WERE | | | SUBMITTED LOOSELY AND NOT BOUND IN SETS. | | | | | | | | | | | | 2) NOTE: OK, HOWEVER SEE NEW NOTES. | | | | | | 3) NOTE:NO, PLEASE SEE RESPONSE MENTIONS PLANS | | | DESIGNED UNDER THE CODES AS NOTED, HOWEVER ALL CODES | | | RELEVANT TO THE DESIGN IN WHICH THE BUILDING IS | | | PERMITTED UNDER SHALL BE STATED ON PLANS. PLEASE SEE | | | THIS IS REQUIRED OF ARCHITECTURAL SHEETS AS WELL AS | | | ELECTRICAL AND FIRE. PLEASE SEE ANY OTHER NOTES WITH | | | RESPECT TO THIS FROM OTHER TRADES. | | | THE FOLLOWING SHALL BE STATED. 2002 NEC/NFPA-70, 2002 | | | NFPA-72, 2003 NFPA-20 AND 2003 NFPA-101. (THE CORRECT | | | NFPA-101 IS NOTED ) | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE BE SURE TO CORRECT THE CURRENT NEC/ NFPA-70 IN | | | EFFECT. | | | PLEASE KNOW, AS OF JULY 1ST, 2003 THE STATE OF FLORIDA | | | ADOPTED THE 2002 | | | NFPA-70 (NEC). PLANS REFERENCE 1999. PLEASE SEE SOME | | | ELECTRICAL COMMENTS WHICH WILL AFFECT THIS. | | | PLEASE SEE NEXT COMMENT WITH RESPECT TO PERMITS APPLIED | | | FOR UNDER THE 2001 FBC BEFORE OCT 1ST, 2005 AND PERMITS | | | ON OCT 1ST, 2005. | | | | | | 4) NOTE:NO, PLEASE SEE THE PREVIOUS NOTES AS THE | | | PHASING OF THIS BUILDING #1 WILL STILL BE OF CONCERN. | | | AS NOTED ON PLANS, IT IS THE INTENT TO OCCUPY PHASES OF | | | THE BUILDING INSTEAD OF COMPLETING ALL AT ONCE. PLEASE | | | SEE THERE ARE SEVERAL ISSUES WHICH CREATE AN CONCERN | | | FOR LIFE SAFETY OF NOT ONLY THE OCCUPANTS HOWEVER ALSO | | | FOR CONSTRUCTION WORKERS PER OSHA REGULATIONS FOR | | | GUARDING O LIVE PARTS AND EXPOSEURE TO UNQUALIFIED | | | PERSONNEL PER 110.27. | | | PLEASE SEE NO INFORMATION FOR SPRINKLER PROTECTION AND | | | HOW SYSTEMS WHICH FEED FROMONE TO ANOTHER SECTION | | | WILL TAKE PLACE. | | | PLEASE SEE THERE ARE CIRCUITS IN PHASES TWO AND THREE | | | WHICH ARE BEING FED FROM PANELS ALREADY ENERGIZED UNDER | | | PHASE ONE. | | | THE HAZARD OF SYSTEMS BEING FED FROM OTHER PARTS OF THE | | | BUILDING WHICH ARE FROM EQUIPMENT ALREADY ENERGIZED IS | | | OF CONCERN. NO INFORMATION OF SCHEDULE SHUT DOWN BY THE | | | DESIGNER AND CONTRACTOR WAS SUBMITTED. | | | PLEASE KNOW DUE TO THE CIRCUITING AS SHOWN ON PLANS FOR | | | BRANCH CIRCUITS, FEEDERS ETC APPROVAL OF THE WAY THE | | | PROPOSED CONSTRUCTION WILL TAKE PLACE IS NOT FINALIZED | | | AT THIS TIME. PLEASE ALSO SEE COMMENTS FROM OTHER | | | TRADES LIKE THE FIRE MARSHAL AND BUILDING PLAN REVIEW. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | 4) NOTE: PLEASESEE THAT THREE SEPARATE PERMIT | | | APPLICATIONS WERE SUBMITTED AND NOTED FOR BLDG'S 1,2 | | | AND 3, HOWEVER PLANS SHOWS BLDG TYPES 1.2&3 | | | STRUCTURALLY ONLY ONE BUILDING. | | | PLEASE SEE PERMIT APPLICATIONS ALL REFLECT THIS ONE 450 | | | UNIT BLDG. | | | PLEASE SEE THIS CONTRADICTS THE "PHASING PLAN" | | | SUBMITTED ON A1.04 AS THIS PHASING PLAN INDICATES WORK | | | ON BLDGS 4 AND 5 BEFORE COMPLETION OF BLDGS 1, 2 AND | | | 3. | | | PLEASE SEE COMMENTS FROM BLDG, FIRE AND OTHER | | | REVIEWERS, AS CERTIFICATES OF OCCUPANCY(CO'S) FOR | | | THESE CAN NOT BE GRANTED IN THIS ORDER AS THE FIRST | | | "STRUCTURED BLDG"(1,2&3) WOULD NOT BE COMPLETE. | | | PLEASE ALSO SEE COMMENTS WITH RESPECT TO "TEMPORARY | | | CO'S" WHICH MAY ALLOW OCCUPANCY OF SOME PARTS OF BLDGS, | | | HOWEVER THESE TCO'S ARE ONLY GOOD FOR 30 | | | DAYS AND A MAX OF 3 TCO'S MAY ONLY BE GRANTED BY THE | | | BLDG OFFICIAL. | | | PLEASE KNOW, IN ANY CASE, ALL LIFE SAFETY, FIRE | | | PROTECTION SYSTEMS, FIRE SPRINKLERS (FULLY CHARGED), | | | ELECTRICAL SYSTEMS ETC SHALL BE COMPLETE IN THE BASE | | | BLDG FOR BLDG TYPE 1, 2& 3 BEFORE A TCO,/CO CAN BE | | | GRANTED. | | | ************************************* | | | ALSO NOTED THAT BLDG'S TYPE 4 AND 5 WHICH ARE SEPARATE | | | STRUCTURES AND INDEPENDENT OF EACH OTHER WERE NOT | | | SUBMITTED FOR PERMIT. | | | PLEASE SEE ALL PERMITS SUBMITTED AFTER OCT. 1ST, 2005 | | | SHALL FALL UNDER THE 2004 FBC, WITH ALL OTHER CODES | | | ADOPTED BY SAID CODE AND STATE OF FLORIDA. | | | | | | ************************************ | | | PLEASE SEE COMMENTS FROM OTHER REVIEWER(S) WITH RESPECT | | | TO THIS. | | | | | | ************************************* | | | PLEASE ALSO SEE NEXT COMMENT WITH RESPECT TO THE MAINS, | | | SERVICES, AND METER RMS AS PROPOSED. | | | ** SEE ALL NOTES FROM ALL REVIEWERS WHICH MAY ALSO | | | AFFECT THIS SEQUENCE OF CONSTRUCTION. | | | | | | 5) NOTE: NO/OK. PLEASE SEE NOTE #4 ABOVE AND PLEASE | | | SEE AS THE RISER HAS BEEN REVISED TO WHAT APPEARS TO BE | | | NEW MAINS. PLEASE PROVIDE INFORMATION ON THE MAIN BEING | | | SHOWN. RISER AND PLANS MAKE REFERENCE TO THESE BEING | | | ?SHUNT-TRIP? WHICH ARE OK, HOWEVER PLEASE BE SURE EACH | | | MAIN CONTAINS THE MANUAL MEANS OF DISCONNECT RATED FOR | | | THE LOED SERVED AS REQUIRED PER 230.79 AND 230.76. | | | PLEASE SEE RISER MENTIONS TO SEE METER CENTER RISER | | | NOTES, HOWEVER RISER NOTES EACH METER CENTER WITH MAINS | | | ALSO. PLEASE SEE NEW NOTES PERTAINING TO GROUNDING. | | | PLEASE SEE PLANS DO NOT CORRELATE WITH THE RISER FOR | | | ALL HOUSE PANELS AND EQUIPMENT. PLEASE SEE PLANS STILL | | | INDICATE HOUSE METERS AT EACH ELECTRICAL ROOM WHEN THE | | | RISER SHOWS ONE HOUSE METER/CT AND ALL HOUSE PANELS ARE | | | FED FROM THE NEW DP. | | | PLEASE SEE NEW NOTES FOR MANY OF THE REVISED ITEMS ON | | | RISER. | | | PLEASE SEE THE NOTES ABOVE WITH RESPECT TO PHASING OF | | | THE PROJECT AND PANELS/FEEDERS AND BRANCH CIRCUITS | | | CROSSING OVER PHASED AREAS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | 5) NOTE: PLEASE SEE METER RMS AS SHOWN WOULD BE OK, | | | HOWEVER STRUCTURE AS SHOWN FOR BLDG TYPE 1, 2 AND 3 | | | (ONE BLDG) WOULD REQUIRE MAINS TO BE GROUPED. 90.4, | | | 230.2, 230.70, 230.72, 230.76, 230.79 ETC. | | | BLDG'S LARGE ENOUGH TO CONTAIN MORE THAN ONE SERVICE AT | | | SEPARATE LOCATIONS SHALL BE DIVIDED INTO SECTIONS AND | | | SHALL HAVE THOSE SECTIONS DIVIDED BY "FIRE WALLS". | | | PLEASE SEE FBC FOR DEFINITION OF "FIRE WALLS". | | | PLEASE KNOW, STRUCTURE CONSTRUCTED AS SHOWN IN PLANS, | | | WOULD REQUIRE MAIN DISCONNECTS GROUPED, WHICH WOULD | | | THEN IN-TURN FEED METER ROOMS. | | | OTHER DESIGN CHANGES IN THE "ONE BLDG" MAY ALSO PERMIT | | | INDIVIDUAL SERVICES. | | | PLEASE SEE BLDG TYPE #4 AND #5 ARE SHOWN AS SEPARATE | | | BLDGS WITH STAND ALONE SERVICES AND ALL MAINS ARE | | | GROUPED. | | | PLEASE KNOW THAT BLDGS 4 AND 5 WILL HAVE REVIEWS DONE | | | UNDER THOSE PERMIT APPLICATIONS. | | | ** PLEASE SEE SOME OF THESE COMMENTS WOULD ALSO APPLY. | | | | | | 6) NOTE:NO, PLEASE SEE THERE ARE SEVERAL AREAS WHICH | | | CIRCUITING IS NOT COMPLETE INCLUDING UNITS FOR SMOKE | | | DEVICES AND MANY AREAS OF HOUSE/COMMON AREAS/ SITE ETC. | | | PLEASE SEE MANY NEW COMMENTS BASED ON PLANS SUBMITTED. | | | PLEASE SHOW ALL AND CORRELATE WITH THE SUBMITTED PANEL | | | SCHEDULES. SEE NEW NOTES ALSO. | | | PLEASE SEE HOUSE CIRCUITS AND NEW NOTES FOR THIS. | | | FBC ADMIN SECTION 104.2.1.2, NEC 408.4, 310.16, 240.4 | | | | | | PLEASE COMPLETE ALL CIRCUITING ON PLANS IN ORDER TO | | | REVIEW CODE COMPLIANCE FOR AREAS OF UNITS AND COMMON | | | AREAS. | | | | | | 7) NOTE: NO, SAME COMMENT. THIS IS NOT EXPLAINED ANY | | | FURTHER. PLEASE HOWEVER ALSO SEE NEW COMMENTS BASED ON | | | PLANS SUBMITTED. | | | ** PLEASE KNOW THERE ARE AREAS OF PLANS WITH | | | DESIGNATIONS, ITEMS FOR CODE COMPLIANCE FOR CIRCUITING | | | TO THOSE AREAS CAN NOT BE VERIFIED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE ROOM AND AREA DESIGNATIONS ON PLANS, | | | INCLUSIVE OF ALL UNITS AND COMMON AREAS. | | | REVIEW FOR SOME CODE COMPLIANCE ITEMS CAN NOT BE DONE | | | AT THIS TIME. | | | | | | 8) NOTE:NO, PLEASE SEE RESPONSE LETTER MENTIONS TO | | | SEE SHEET AP E16.00A, YET PLEASE KNOW COMPLETED | | | PHOTO-METRICS SHALL BE SUBMITTED IN EACH SUBMITTED | | | PLANS FOR EACH BUILDING AS EACH BUILDING IS ITS OWN | | | LEGAL RECORD. | | | PLEASE SEE THE LAYOUT IN THIS BUILDING IS NOT THE SAME | | | AS OTHER AND SEPARATE EGRESS PATHS ARE PRESENT. PLEASE | | | ALSO SEE NEW NOTES PERTAINING TO ELEVATOR CORRIDOR. | | | PLEASE ALSO SEE PREVIOUS NOTES, PLEASE SEE ONLY PARTIAL | | | PHOTO-METRICS WERE SUBMITTED. PLEASE SEE NOTE WHICH | | | REQUIRES ALL UNDER NORMAL AND EMERGENCY AND FOR ALL | | | EGRESS AREAS. PLEASE SEE ONLY SOME ARE BEING SHOWN IN | | | THE PLANS UNDER BUILDING ONE. PLEASE KNOW THESE CAN BE | | | TYPICAL, HOWEVER THEY SHALL ALSO BE SPECIFIC TO EACH | | | AREA IF THE LAYOUT OF THESE AREAS CHANGES WHICH THEY | | | DO. NOT ALL AREAS ARE THE LIKE. | | | PLEASE ALSO SEE MISSING PHOTO-METRICS FOR CLUBHOUSE | | | PLANS, STAIRS AND EGRESS PATHS. | | | PLEASE SEE NEW NOTES ALSO FOR EGRESS FROM UNITS AND | | | PLEASE SEE NEW NOTES PERTAINING TO PARKING LOT, AND | | | SITE LIGHTING. | | | THIS COMMENT HAS BEEN PRIMARILY THE SAME NOTE FOR ALL | | | THREE BUILDING PERMIT APPLICATIONS. | | | PLEASE KNOW AS THE SWIMMING POOL IS NOT UNDER THIS | | | PERMIT FOR THE BUILDING, STAMPED PLANS FROM PALM BEACH | | | COUNTY HEALTH DEPT IS NOT REQUIRED AT THIS TIME UNDER | | | THIS PERMIT. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE COMPLETE PHOTO-METRICS FOR ALL COMMON | | | AREAS, GARAGE AREA, COMMON AREA CORRIDORS, STAIR TOWERS | | | ETC. | | | PLEASE SEE 2003 NFPA-101 7.8.1.3 AND 7.9.2.2 WHICH | | | REQUIRE A MIN OF 10FT CANDLES FOR STAIR TOWERS UNDER | | | NORMAL OPERATION AS WALK SURFACE AND A MIN OF 1FT | | | CANDLE AT WALK SURFACE UNDER EMERGENCY CONDITIONS. | | | PLEASE ALSO SEE OTHER WALK AREAS, GARAGE, CORRIDORS ETC | | | AND THE MIN OF 1FT CANDLE. | | | **PLEASE SEE PALM BEACH COUNTY SECURITY CODE ORDINANCE | | | WITH RESPECT TO MIN DESIGN OF PARKING LOT LIGHTING | | | LEVELS UNDER NORMAL CONDITIONS. (ONLY NOTED FOR DESIGN) | | | NOT REQUIRED. PLEASE SEE ANY REQUIREMENTS FROM INS | | | CARRIER WHICH REQUIRES A MIN LEVEL OF LIGHTING. | | | ** PLEASE SEE PHOTO-METRICS OR SITE PLAN WAS NOT | | | SUBMITTED FOR PROPOSED POOL AREA. THE POOL STRUCTURE IS | | | REQUIRED TO BE UNDER A SEPARATE PERMIT. PLEASE KNOW, | | | THE PHOTO-METRICS FOR POOL AREA WILL BE REQUIRED AND | | | WILL ALSO BE REQUIRED TO BE REVIEWED AND STAMPED BY THE | | | PALM BEACH COUNTY HEALTH DEPT FOR ANY PROPOSED | | | NIGHT-TIME SWIMMING. | | | | | | 7) NOTE: NO, PLEASE SEE EACH SET OF PLANS SHALL CONTAIN | | | A SITE LIGHTING PLAN SHOWING ALL CIRCUITING AND | | | CORRELATE WITH EACH OF THE HOUSE PANELS FOR EACH | | | BUILDING IN WHICH THEY ARE BEING CIRCUITED TO. PLEASE | | | SEE ALL SITE LIGHTING AS SHOWN IN THE SET OF PLANS FOR | | | BUILDING ONE. PLEASE SEE THE CIRCUITING AS SHOWN DOES | | | NOT CORRELATE WITH HOUSE PANEL FOR BUILDING THREE IN | | | ANY WAY. | | | PLEASE SEE THERE ARE CIRCUITS SHOWN IN THIS BUILDING | | | ALSO DO NOT CORRELATE WITH THE PANEL SCHEDULE AS | | | SUBMITTED. | | | PLEASE SEE HOUSE PANEL FOR THESE CIRCUITS ARE IN FACT | | | BLANK AND SHOWS THE WORDING OF "SPACE". PLEASE KNOW AT | | | THIS TIME THERE ARE MANY ITEMS PERTAINING TO SITE | | | LIGHTING WHICH CAN NOT BE VERIFIED FOR VOLTAGE DROP, | | | CIRCUITS, OVER CURRENT PROTECTION, CONDUCTOR SIZES | | | ETC. | | | PLEASE SEE NO INFORMATION WAS SUBMITTED OR SHOWN FOR | | | WIND LOADS ON POLES. | | | 240.4, 310.16, 408.4, FBC 104.2.1,104.21.2 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE NO "ELECTRICAL SITE-PLAN" WAS SUBMITTED FOR | | | ANY SITE LIGHTING, LANDSCAPE LIGHTING ETC. | | | PLEASE KNOW, IF NOT SUBMITTED UNDER THIS PERMIT AND | | | VALUES ADJUSTED ACCORDINGLY, SEPARATE PERMIT , PLANS | | | AND FEES WILL BE REQUIRED FOR ALL SITE LIGHTING, | | | LANDSCAPE LIGHTING WORK. | | | ** ALSO NOTE: IN THAT COMPLETE WIND LOADING | | | CALCULATIONS FOR LT POLES INCLUSIVE OF THE ATTACHMENT | | | OF LT FIXTURES WILL BE REQUIRED TO BE SUBMITTED WITH | | | PLANS AND PERMIT APPLICATION FOR REVIEW. | | | | | | 8) NOTE: NO, PLEASE SEE NOT ALL ROOMS AND AREAS ARE | | | CLEAR. IT APPEARS FOR THE MOST PART IN BUILDING #1 THIS | | | HAS BEEN DONE. THE NOTE WILL REMAIN AS NEW NOTES | | | PERTAINING TO FIXTURES AND CIRCUITING MAY AFFECT THESE | | | AS SHOWN. PLEASE SEE NEW NOTES PERTAINING TO THE | | | ELEVATOR EQUIPMENT ROOM. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INCLUDE AN EMERGENCY BATTERY BACK UP LT OF SOME | | | SORT IN ALL ELECTRICAL ROOMS, FIRE PUMP ROOM, AND | | | ELEVATOR MACHINE RMS. SOME ARE SHOWN, BUT NOT ALL. | | | 7.8,7.9, 700.16 ETC | | | | | | 9) NOTE:NO, PLEASE SEE CIRCUITING FOR MANY OF THE | | | CIRCUITS NOT SHOWN ON PLANS CAN NOT BE VERIFIED FOR THE | | | REQUIRED DEDICATED CIRCUITS. PLEASE SEE PLANS AND | | | CORRELATE WITH THE HOUSE PANEL FOR THIS BUILDING. | | | PLEASE ALSO SEE NEW NOTES PERTAINING TO THE EQUIPMENT | | | ROOM. | | | PLEASE SEE 620.22,23,24 AND 620.51 ETC | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 620.23, AND 620.24 FOR REQUIRED DEDICATED | | | BRANCH CIRCUITS FOR ELEVATOR PITS, AND ELEVATOR MACHINE | | | RMS/EQUIPMENT AREAS. | | | PLEASE ADJUST HOUSE PANELS AS NEEDED. | | | | | | 10) NOTE: NO, PLEASE SEE NO INFORMATION WAS LOCATED ON | | | RISER SHEETS. PLEASE SEE NOT ENOUGH INFORMATION WAS | | | SHOWN ON FP FOR THE FIRE PUMP, SIZE, FUEL CONSUMPTION, | | | TIME OF OPERATION UNDER THE AMOUNT OF FUEL ETC. PLEASE | | | SEE THE SPECS/CUT SHEETS SUBMITTED CONTAIN MULTIPLE | | | UNITS AND NO REVIEW FOR CODE COMPLIANCE OF THE UNIT FOR | | | EACH BUILDING BASED ON THE NUMEROUS PUMPS SUBMITTED. | | | PLEASE ALSO SEE MISSING FIRE PUMP CONTROLLER SPECS. | | | PLEASE ALSO SEE MISSING THE RELEVANT CODES ON FP | | | SHEETS. | | | PLEASE SEE THAT THIS BUILDING DOES NOT SEEM TO BE | | | FULLY SPRINKLED. | | | PLEASE SEE A LAYOUT FROM UNITS COULD NOT BE SEEN FOR | | | PROTECTION, SEE FIRE REVIEW NOTES. PLEASE ALSO SEE | | | NOTES PERTAINING TO SMOKE DETECTOR/ALARM DEVICES | | | REQUIREMENTS. | | | PLEASE KNOW AS EACH BUILDING IS UNDER A SEPARATE | | | PERMIT, THREE SETS OF PLANS SHALL BE ACCOMPANIED BY | | | THREE SETS OF ALL SUBMITTALS AS REQUESTED. | | | PLEASE SEE NFPA-20 FOR ALL REQUIREMENTS FOR ROOM. | | | PLEASE KNOW BASED ON THE PLANS SUBMITTED AND SPEC/CUT | | | SHEETS SUBMITTED, REVIEW FOR COMPLIANCE CAN NOT BE DONE | | | AT THIS TIME. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE ELECTRICAL RISER SHOULD "NOTE" FIRE PUMP | | | AS DIESEL AS NOTED ON FP SHEETS. | | | PLEASE SUBMIT ALL MANUFACTURES SPEC/CUT SHEETS FOR FIRE | | | PUMP CONTROLLER AS REVIEW FOR CODE COMPLIANCE UNDER | | | 2003 NFPA-20 IS REQUIRED. | | | PLEASE ALSO SUBMIT ALL MANUFACTURES SPECS/CUT SHEETS | | | FOR FUEL TANK. | | | PLEASE SEE NFPA-20 9.6.2.2 AS THE FUEL CAPACITY IS | | | REQUIRED TO BE SIZED BASE ON THE 100% RATED LOAD FOR A | | | MIN OF 8HRS, OR TIME SO DETERMINED BY THE FIRE | | | MARSHAL'S OFFICE DEPENDING ON OCCUPANCY. | | | FUEL SYSTEMS WILL BE UNDER OTHER TRADE REVIEW(S). (FIRE | | | AND MECH). | | | | | | 11) NOTE: NO, RESPONSE MENTIONS THIS WAS DONE, HOWEVER | | | PLEASE SEE UNIT PANEL SCHEDULES AND HOUSE PANEL | | | SCHEDULE DOES NOT CONTAIN AND CONDUCTOR SIZES. PLEASE | | | KNOW BASED ON COMMENTS ABOVE WITH RESPECT TO AREA | | | DESIGNATIONS, CIRCUITING MISSING ON PLANS, REVIEW OF | | | THIS CAN NOT BE DONE AT THIS TIME.408.4 , FBC 104.1.2 | | | ADMINSECTION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INCLUDE ALL MINIMUM CONDUCTOR SIZES ON ALL | | | PANELS, UNITS AND HOUSE PANELS. REVIEW FOR THESE ITEMS | | | OF CODE COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | 310.16, 240.4,215.5 | | | | | | 12) NOTE:NO, AS CIRCUITING FOR THIS BUILDING IS NOT | | | COMPLETE AT THIS TIME, THE OVER CURRENT PROTECTIVE | | | DEVICES CAN NOT BE VERIFIED AT THIS TIME. THIS COMMENT | | | WAS MAINLY FOR THE OCP DEVICES WHICH WERE BEING SHOWN | | | ON BUILDING #1'S PLANS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE GARAGE/HOUSE LIGHTING BEING INDICATED ON 30A | | | AND 50A CIRCUITS. | | | PLEASE SEE CODE DOES LIMIT THE OCP FOR UNIT FIXTURES | | | FOR PROTECTION OF FIXTURES ON A BRANCH CIRCUIT. PLEASE | | | ADJUST CIRCUITING AS NEEDED. | | | PLEASE ALSO SEE A FIXTURE SCHEDULE CONTAINING WATTAGES, | | | VOLTAGES ETC WAS NOT SUBMITTED. | | | PLEASE VERIFY IF THESE UNIT FIXTURES ARE RATED TO HAVE | | | OCP AT ABOVE MENTIONED. | | | 240.4, 310.16 ETC | | | | | | 13) NOTE: OK, HOWEVER SEE NOTES. | | | | | | 14) NOTE:NO/OK, PLEASE SEE PART OF THIS COMMENT SEEMS | | | TO HAVE BEEN ADDRESSED, HOWEVER PLEASE SEE NOTES ON | | | RISER AND RISER NOTES WHICH STILL DO NOT CORRELATE. | | | PLEASE SEE TYPICAL NOTE #4 AND #7 DO NOT CORRELATE ON | | | RISER. | | | PLEASE SEE SEVERAL NOTE #1'S, YET ON RISER NOTES NOT | | | ALL OF THESE NOTE #1'S CAN POSSIBLY APPLY.PLEASE SEE | | | NEW NOTES FOR NEW MAINS. | | | PLEASE ADJUST ALL NOTE SON RISER AND NOTES NOTED AS | | | RISER NOTES. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | , PLEASE SEE PLEASE SEE MAX OCP TO BE SIZED FOR | | | PANELS/EQUIPMENT BEING FED BY SAID OCP. | | | PLEASE SEE MANY UNIT PANELS ARE SHOWN AS 100A MLO, WITH | | | 125A OCP AS LISTED ON RISER ETC. | | | PLEASE ALSO SEE RISER NOTE #4 WHICH INDICATES 125A | | | 2-POLE ETC, HOWEVER PLEASE SEE RISER AS THIS NOTE #4 | | | COULD NOT BE LOCATED. (APPEARS TO BE MISPRINTED FOR | | | "NOTE#7" ON RISER) 240.4,408,310.16,215.5 ETC. | | | | | | 15) NOTE: N/A, NOT PART OF THESE PLANS FOR THIS | | | BUILDING. SEE NEW NOTES. | | | | | | 16) NOTE: N/A, NOT PART OF THESE PLANS FOR THIS | | | BUILDING. SEE NEW NOTES. | | | | | | 17) NOTE: N/A, NOT PART OF THESE PLANS FOR THIS | | | BUILDING. SEE NEW NOTES. | | | | | | 18) NOTE: NO/OK, SOME SHEETS SHOW NOTE, HOWEVER NOT ALL | | | FOR UNITS. CIRCUITING IS NOT YET COMPLETE TO REVIEW | | | THESE FOR CODE COMPLIANCE. | | | PLEASE KNOW THAT IF BUILDING DOES NOT FALL UNDER | | | EXEMPTION OF NFPA FOR SMOKE DEVICES REQUIRED INSIDE | | | SLEEPING ROOMS, THEN THESE WILL BE REQUIRED TO BE SHOWN | | | AND CIRCUITED. PLEASE BE AWARE THAT ONCE THESE DEVICES | | | (IF SMOKE ALARMS AT 120V) ARE INSTALLED, THESE WOULD BE | | | REQUIRED TO BE ON A ARC FAULT PROTECTED CIRCUIT. PANEL | | | SCHEDULE AND/OR CIRCUITING MAY NEED TO BE ADJUSTED. | | | PLEASE LABEL ALL CIRCUITS ON PANEL SCHEDULE WHICH | | | CONTAIN AFCI PROTECTION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THESE SHEETS ALSO REFERENCE "ARC FAULT" | | | PROTECTION FROM THE 1999 NEC, WHICH ONLY REQUIRED | | | PROTECTION OF RECEPTS. | | | PLEASE SEE THE 2002 NEC WHICH REQUIRES PROTECTION FOR | | | ALL "OUTLETS" IN BEDRMS. THIS IS INCLUSIVE OF RECEPTS, | | | LTS, FANS, SMOKE DETECTORS ETC. PLEASE SEE NOTE ON UNIT | | | PLANS AND ADJUST. | | | | | | 19) NOTE:THIS IS UNCLEAR AT THIS TIME, AS PERMIT | | | APPLICATION FOR BUILDING #1 INDICATES 450 UNITS AND | | | THAT IS WHAT WAS ORIGINALLY APPLIED FOR ON ORIGINAL | | | APPLICATION AND ENTERED INTO OUR SYSTEM. | | | PLEASE SEE THE NEW PERMIT APPLICATION FOR THE NEW | | | CONTRACTOR DOES NOT DESCRIBE WORK IN DETAIL PROPOSED | | | FOR THIS PARTICULAR BUILDING. ONLY MENTIONS NEW | | | CONSTRUCTION FOR APARTMENT COMPLEX. PLEASE BE SURE TO | | | CORRELATE EACH APPLICATION FOR EACH BUILDING AND BE | | | SURE ALL INFORMATION IS COORDINATED WITH THE BUILDING. | | | PLEASE CORRELATE PLANS, PERMIT APPLICATIONS AND ADJUST | | | PLANS AS NEEDED. | | | FBC 104.2.1.2 ADMIN SECTION. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE CORRELATE LOADS, UNITS, PANELS, AND | | | BUILDING/METER LOAD CALCULATIONS: | | | A) PLEASE SEE PANEL SCHEDULE/LOAD CALCULATIONS FOR UNIT | | | "B-3" SHOWN ON | | | 16.26, HOWEVER THIS UNIT TYPE OR LOADS COULD NOT BE | | | LOCATED ON BLDG LOAD CALCULATIONS ON 16.25? | | | B) PLEASE ALSO SEE THE SAME COMMENT ABOVE FOR UNIT | | | "C-2" WHICH IS ALSO SHOWN ON | | | 16.26 BUT NOT IN CALCS ON 16.25?? | | | ** PLEASE ADJUST ALL AS NEEDED. | | | | | | 20) NOTE: OK, HOWEVER STILL NOT ADDED TO RISER, ONLY | | | SHOWN IN GROUNDING DETAIL. PLEASE EXPLAIN RATIONAL OF | | | TWO GROUNDING ELECTRODE SYSTEMS SHOWN? | | | PLEASE SEE METER CENTER "SCHEDULE" WHICH INCLUDES A | | | 3/0, HOWEVER SEE NEW NOTES FOR GROUNDING ELECTRODE, | | | EQUIPMENT GROUNDING CONDUCTORS ETC. | | | PLEASE ALSO SEE NEW NOTES. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE INCLUDE THE REQUIRED FOOTER STEEL ON THE | | | GROUNDING ELECTRODE RISER DETAIL. PLEASE ALSO SHOW ON | | | RISER. | | | 250.50. | | | | | | 21) NOTE: NO, PREVIOUS NOTE REQUESTED A NOTE/DETAIL | | | WHICH WOULD ACTUALLY PROVIDE A LITTLE MORE INFORMATION | | | FOR THIS REQUIREMENT. PLEASE EXPAND ON NOTE. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE PROVIDE A DETAIL/NOTE FOR ALL RACEWAY SEALS AS | | | REQUIRED PER | | | 230.8 | | | | | | 22) NOTE: N/A, HOWEVER SEE NEW NOTES. | | | | | | 23) NOTE: N/A, HOWEVER SEE NEW NOTES. | | | | | | 24) NOTE: N/A. | | | | | | 25) NOTE: OK, HOWEVER SEE NEW NOTES. | | | | | | 26) NOTE: OK. | | | | | | 27) NOTE: OK. | | | | | | 28) NOTE:NO, PLEASE SEE THIS BUILDING DOES NOT SEEM | | | TO BE FULLY SPRINKLED. PLEASE SEE LAYOUTS PROVIDED ON | | | FP SHEETS DO NOT INDICATE HEADS IN ANY OF THE UNITS ON | | | PLANS. THERE ARE NOTES FOR SOME CLOSETS AND BATHROOMS; | | | HOWEVER THOSE DO NOT CORRELATE WITH PLANS AS NO HEADS | | | ARE SHOWN FOR COVERAGE. PLEASE SEE FIRE MARSHAL'S | | | REVIEW AS THE BASE SYSTEM IS REQUIRED UNDER THE | | | BUILDING PERMITTED SET OF PLANS EVEN THOUGH THE FS | | | PERMIT WILL BE SEPARATE WITH SEPARATE PLANS ETC. | | | PLEASE ALSO SEE NOTES PERTAINING TO CIRCUITING AND | | | PLEASE SEE NEW NOTES FOR THESE DEVICES AND TYPES | | | SHOWN. | | | PLEASE SEE 2001 FBC 905.2 WHICH IS MORE RESTRICTIVE AND | | | DOES NOT CONTAIN THE EXCEPTION. | | | PLEASE REVIEW LOCATIONS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | SMOKE DETECTORS ARE REQUIRED INSIDE AND OUTSIDE ALL | | | SLEEPING ROOMS. | | | PLEASE SEE 2002 NFPA-72 11.5.3.1 | | | PLEASE ADJUST NOTE FOR SD'S ON PLANS AS | | | SD'S ARE REQUIRED 3' FROM BATH/KITCHEN DOORS, 3' FROM | | | SUPPLY AIR DIFFUSERS, 5' FROM R/A GRILLES AND 20' FROM | | | KITCHEN COOKING APPLIANCES. W/ EXCEPTIONS FOR DISTANCES | | | FROM COOKING APPLIANCES. (PHOTO-ELECTRIC AND RESETTING | | | TYPE) | | | ** PLEASE SEE PREVIOUS NOTES WITH RESPECT TO ARC FAULT | | | PROTECTION OF SD'S AND CIRCUITING. | | | | | | 29) NOTE: N/A PER THIS BUILDING REVIEW. | | | | | | 30) NOTE: NO, AS CIRCUITING IS NOT YET COMPLETE FOR ALL | | | COMMON AREAS THIS CAN NOT BE VERIFIED. PLEASE ALSO SEE | | | NOTES PERTAINING TO FIXTURES TYPES ETC. | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE 700.12E FOR CIRCUITING OF ALL EM/EXT LTS, | | | WHICH REQUIRES THE BRANCH CIRCUIT FEEDING THE UNIT | | | EQUIPMENT, SHALL BE THE SAME BRANCH CIRCUIT AS THAT | | | SERVING THE NORMAL LIGHTING IN THE AREA AND CONNECTED | | | AHEAD OF ANY LOCAL SWITCHES. | | | THIS IS NOTED ON SOME SHEETS, HOWEVER CIRCUITING FOR | | | THESE IS NOT SHOWN. | | | 215.5 | | | | | | 31) NOTE: OK. | | | | | | 32) NOTE:NO, PLEASE SE SOME UNITS ARE STILL MISSING | | | GFI RECEPTS TO SERVE KITCHEN COUNTER SPACE AS | | | REQUIRED. | | | UNIT(S) A 1, A-2, C1, C3 ETC. PLEASE GO THROUGH ALL. | | | | | | **PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 210.52C1-C5 FOR REQUIRED GFI RECEPTS ALONG | | | KITCHEN COUNTER SPACE. PLEASE SEE SOME ARE SHOWN ON | | | WHAT APPEARS TO BE A WALL ON THE OTHER SIDE OF THE | | | COUNTER SPACE. | | | PLEASE SEE B-2, B-4ETC. | | | PLEASE SEE OTHER WHICH ARE REQUIRED TO BE WITHIN 2' OF | | | THE END OF THE COUNTER SPACE/FROM SINK EDGE ETC. PLEASE | | | SEE THESE AREAS REDLINED ON SHEETS. | | | | | | 33) NOTE:NO, PLEASE SEE RESPONSE MENTIONS THIS IS FOR | | | SECURITY AND IT IS NOT A PLUG-IN TYPE TRANSFORMER. IF | | | THIS IS NOT A PLUG-IN TYPE, PLEASE INDICATE ON PLANS | | | WHAT TYPE IT IS AND/OR WILL BE. PLEASESUBMIT OR | | | RELOCATE THE RECEPTACLES LOCATED ABOVE CLOTHES CLOSET | | | SHELVING OR IN THE NEAR VICINITY AS PREVIOUSLY STATED | | | THIS AHJ HAS SEEN TOO MANY INSTANCE WHERE FIRES HAVE | | | STARTED BASED ON SOME TYPES OF THESE UNITS AND IN THE | | | INTEREST OF LIFE SAFETY AND PROPERTY DAMAGE, THESE WILL | | | NOT BE PERMITTED AS SHOWN IN SOME UNITS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE WHAT APPEARS TO BE A RECEPT LOCATED IN THE | | | CLOTHES CLOSET FOR PERHAPS A LV PLUG-IN TYPE | | | TRANSFORMER? | | | PLEASE KNOW, THE ONLY LOCATION A RECEPT IS PERMITTED IN | | | A CLOTHES CLOSET FOR THIS PURPOSE, MUST BE LOCATED | | | DIRECTLY ABOVE DOOR AWAY FROM COMBUSTIBLES. | | | MANY PLUG-IN TYPE TRANSFORMERS BECOME VERY HOT AND | | | HAVE MELTED OR CAUSED FIRES IN THIS JURISDICTION. | | | PLEASE KNOW, MANY ITEMS IN A CLOTHES CLOSET ARE AN | | | ACCELERANT. | | | THESE RECEPTS MAY BE MOVED TO UTILITY RM IF SO | | | DESIRED. | | | 110.26, 240.24, 90.4 ETC | | | | | | 34) NOTE: OK. | | | | | | 35) NOTE: OK. | | | | | | ** NEW NOTES FOR THIS REVIEW ** | | | | | | 1) NOTE: PLEASE SUBMIT AND SHOW ALL FIXTURE | | | DESIGNATIONS ON PLANS. PLEASE SEE SOME OF THE NOTES | | | WHICH MENTION A PARTICULAR FIXTURE DO NOT CORRELATE | | | WITH THE FIXTURE SCHEDULE PROVIDED. PLEASE SEE OTHERS | | | ARE SHOWN WITH OUT ANY WATTAGE USE OR DESIGNATION(S). | | | PLEASE COMPLETE AND COORDINATE ALL AS THESE CAN NOT BE | | | REVIEWED FOR COMPLIANCE AT THIS TIME. | | | | | | 2) NOTE: PLEASE SEE PLANS SUBMITTED SEEM TO CONTAIN | | | UNITS WHICH ARE NOT PART OF THIS PARTICULAR BUILDING? | | | PLEASE SEE C-3. PLEASE SEE THESE DO NOT SEEM TO BE ON | | | ARCHITECTURAL PLANS. | | | 104.2.1.2, ADMIN SECTION | | | NEC 408.4, 240.4, 310.16 TO BE VERIFIED. | | | | | | 3) NOTE: PLEASE SEE THE THRESHOLD INSPECTION PLANS | | | SUBMITTED ALL CONTAIN A RAISED SEAL OVER A PHOTO-COPIED | | | SIGNATURE FROM THE ENGINEER. PLEASE SEE FLORIDA | | | ADMINISTRATIVE CODE 61G15-23.002 AND FLORIDA STATUTES | | | 471.025 AS AN ORIGINAL SIGNATURE IS REQUIRED. PLEASE | | | KNOW THESE MAY BE RETAINED BY THIS OFFICE FOR POSSIBLE | | | REVIEW FROM THE FLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS. IF THERE ARE ANY QUESTIONS ON THIS PLEASE | | | CONTACT THIS OFFICE OR THE BOARD. | | | **THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | ANY OTHER TRADE. | | | | | | 4) NOTE: PLEASE SEE NFPA-72 DEFINITIONS FOR SMOKE | | | DEVICES. IF THESE ARE INDEED (SD) FOR SMOKE DETECTORS | | | THEN THEY WOULD DETECT AND CAUSE AN ALARM TO HORN/SIREN | | | DEVICE OF SOME TYPE. PLEASE SEE PLANS CALL FOR THESE AS | | | 120V UNITS, WHICH IF (SA) SMOKE ALARMS WHICH WOULD | | | DETECT AND SOUND, THEN THE DESIGNATIONS NEED TO BE | | | ADJUSTED ALONE WITH ALL NOTES WHICH CURRENTLY STATE | | | SMOKE DETECTORS. PLEASE KNOW THIS WAS NOT A COMMENT ON | | | THE PREVIOUS REVIEW, HOWEVER AS INFORMATION WAS GIVEN | | | FROM NFPA DIRECTLY, PLANS MUST CONTAIN THE CORRECT | | | DESIGNATIONS. | | | | | | 5) NOTE: PLEASE SEE THE BASE FA SYSTEM SHALL BE SHOWN | | | AND ALL HORN/STROBE DEVICES SHALL STATE THE MINIMUM | | | LEVELS AS REQUIRED PER FBC 11-4.28.1, .2, AND .3(4). | | | THIS WAS NOT PART OF THE ELECTRICAL REVIEWERS REVIEW | | | WHEN PLANS WERE SUBMITTED PREVIOUSLY HOWEVER THIS HAS | | | NOW BECOME PART OF THE ELECTRICAL REVIEWERS REVIEW. | | | PLEASE SHOW. | | | | | | 6) NOTE: PLEASE CLARIFY STAIRS SHOWN ON SOME UNITS AS | | | NOTED ABOVE IN NOTE #2 FOR NEW REVIEW NOTES. | | | PLEASE SEE IF UNIT #C3 IS BEING DONE IN THIS BUILDING , | | | INCLUDE REQUIRED FIRST FLOOR ELECTRICAL.210.52 | | | PLEASE SEE MISSING WHAT WOULD BE EGRESS LIGHTING AND | | | CONTROLS IF INSIDE UNIT AND/OR OUTSIDE UNIT. PLEASE SEE | | | NEC 210.70, LS 101 7.8, (7.9 WHERE APPLICABLE). | | | | | | 7) NOTE: PLEASE SEE SEVERAL HOUSE CIRCUITS AS NOTED | | | ABOVE WITH RESPECT TO CORRELATION OF CIRCUITING SEEM TO | | | BE INDICATE ON THESE PLANS TO PANELS WHICH WOULD BE ON | | | OTHER BUILDINGS? PLEASE SEE MISSING WHAT APPEARS TO BE | | | A TRASH ROOM(S) AND ANY CIRCUITING FOR LIGHTS, | | | COMPACTOR ETC. | | | 240.4, 310.16, 408.4, ETC | | | | | | 8) NOTE: PLEASE SEE NOTES ABOVE ON PREVIOUS REVIEW AND | | | SECOND REVIEW NOTES WITH RESPECT TO ROOM/AREA | | | DESIGNATIONS. PLEASE SEE 210.52B1, 210.11C1 AND 220.16 | | | FOR DINING ROOMS, DINING AREAS, BREAKFAST AREAS, | | | KITCHEN AREAS AND THE LIKE. PLEASE SEE THAT SOME | | | RECEPTS ARE BEING SHOWN IN AREAS WHICH WOULD APPEAR TO | | | BE AREAS OF THE LIKE AS REFERENCED ABOVE, HOWEVER SOME | | | OF THESE RECEPTS ARE BEING SHOWN ON LIGHTING CIRCUITS | | | OF 15A'S ETC. PLEASE SEE THAT ANY OF THESE AREAS OF THE | | | LIKE WILL BE REQUIRED TO CONTAIN THESE RECEPTACLES ON | | | THE ONE OR MORE CIRCUITS AS NOTED. | | | PLEASE ADJUST PLANS FOR PREVIOUS NOTE AND THIS NOTE. | | | | | | 9) NOTE:PLEASE SEE ELEVATOR CORRIDOR ON 16.06 AND ANY | | | POSSIBLEBUILDING CODE COMMENTS BASED ON DEAD-END | | | CORRIDORS AND DISTANCES PERMITTED ETC WITH AND/ OR WITH | | | OUT BEING SPRINKLED. | | | THIS IS ONLY BEING NOTED AS IF THE LAYOUT HAS TO CHANGE | | | FOR ANY REASON, THIS WILL AFFECT THE ELECTRICAL PLANS. | | | | | | 10) NOTE: PLEASE PROVIDE NOTE ON FIRST FLOOR MAIN | | | ELECTRICAL ROOM PLANS WHICH WILL REQUIRE DOOR TO | | | CONTAIN PANIC HARDWARE. | | | 110.26/90.4 | | | | | | 11) NOTE: PLEASE SEE THE VOLTAGE DROP FOR 30A CU'S, AT | | | THIS TIME CAN NOT BE VERIFIED. PLEASE SEE SOME UNITS | | | INDICATE #10 ALREADY YET THESE WILL BE OVER 75FT AND | | | THERE IS NO NOTE FOR THESE UNITS TO UPGRADE TO #8 OR ? | | | PLEASE ADJUST AND PROVIDE ADDITIONAL INFORMATION. FBC | | | 104.2.1.2 FOR ADDITIONAL INFORMATION. | | | NEC 310.16, 240.4 ETC. | | | | | | 12) NOTE: PLEASE SEE NOTES ABOVE WHICH REQUESTS FOR THE | | | RISER NOTES TO CORRELATE WITH THE DESIGNATIONS ON | | | RISER. PLEASE SEE NOTE #1. PLEASE SEE THIS SAME NOTE IS | | | PROVIDED FOR METER CENTERS, HOWEVER THE NEW MAINS WILL | | | NOT BE METER CENTERS. | | | 104.2.1.2 FBC ADMIN SECTION. | | | | | | 13) NOTE: PLEASE PROVIDE A DETAIL FOR THE ROOF TOP | | | DISCONNECT AS BEING NOTED AND HOW THIS WILL BE MOUNTED? | | | (NOT TO UNIT) | | | 440.11. THIS CAN BE A TYPICAL DETAIL. | | | | | | 14) NOTE: PLEASE SEE ATTACHED COPY OF FLORIDA STATUTES | | | 553.80(2)(B) WITH RESPECT TO REPEAT CODE COMPLIANCE | | | COMMENTS. THIS IS ONLY A NOTICE GIVEN AT THIS TIME. | | | ** PLEASE KNOW ONE SET OF EACH OF THE PLANS FOR EACH | | | BUILDING WILL BE RETAINED BY THIS OFFICEE. | | | | | | 15) NOTE: PLEASE SEE COMPLETE CLUBHOUSECIRCUITING AS | | | NOTED IN OTHER REVIEW COMMENTS, HOWEVER THIS IS BEING | | | NOTED FOR THE CLUBHOUSE TO EMPHASIZE THIS AND ALL ROOM | | | AND AREA DESIGNATIONS. | | | FBC 104.2.1.2 ADMIN SECTION AND NEC FOR REVIEW OF | | | AREAS. 700.12E AS NOTED ABOVE ETC. | | | | | | 16) NOTE: PLEASE SEE 2ND FLOOR EXIT LIGHT OUTSIDE ON | | | THE BUILDING IC SIDE WHICH PLACES THIS EXIT SIGN AT THE | | | EGRESS DOORS FROM CLUBHOUSE. AN OCCUPANT IN THIS | | | CORRIDOR WOULD READ THIS AS AN EXIT IN WHICH DOORS OPEN | | | IN THE DIRECTION OF TRAVEL ETC. | | | PLEASE REVIEW THE LOCATIONS AS SHOWN AND SEE POSSIBLE | | | FIRE REVIEW NOTES. | | | | | | 17) NOTE: PLEASE SEE FIRE REVIEW COMMENTS WITH RESPECT | | | TO ADDRESSING OF BUILDING AND THE LOCATION OF THE | | | REQUIRED FIRE ALARM CONTROL PANEL. PLEASE SEE THE | | | LOCATIONS WILL BE REQUIRED BY THE FIRE MARSHAL'S | | | OFFICE. PLEASE SEE PLANS CURRENTLY SEEM TO SHOW | | | MULTIPLE LOCATIONS WHICH ARE UNCLEAR AT THIS TIME. THIS | | | COMMENT IS BEING MADE AS THIS WILL AFFECT THE | | | ELECTRICAL PLANS. | | | | | | 18) NOTE: PLEASE NOTE/INDICATE THE FEEDERS ON THE RISER | | | FROM THE NEW MAINS OUT TO THE METER CENTERS. PLEASE | | | KNOW AS THE METER CENTER SCHEDULE SEEMS TO INDICATE | | | GROUNDING ELECTRODE AND NOT EQUIPMENT GROUNDING | | | CONDUCTOR, IT IS UNCLEAR WHICH TO USE. A NOTE OF WHICH | | | TO USE AND WHEN, OR ADJUSTING THE RISER AND RISER NOTES | | | WOULD PROVIDE MORE DETAILS FOR THIS. | | | PLEASE SEE NOTES WHICH WILL REQUIRE A "FLOATING | | | NEUTRAL" AFTER THE FIRST MEANS OF DISCONNECT WILL BE | | | REQUIRED ON RISER SHEETS. PLEASE SEE 250.6 AND 250.24B | | | AS NEW MAINS ARE INSTALLED AND THE METERS WHICH CONTAIN | | | NEUTRALS MAY NOT BE BONDED AFTER THE FIRST MEANS OF | | | DISCONNECT. | | | FBC 104.2.1.2 ADMIN SECTION. | | | | | | 19) NOTE: PLEASE SEE POWER FOR ELEVATOR IS BEING NOTED | | | ON THE FORTH FLOOR PLANS? PLEASE ALSO SEE SEVERAL | | | LOCATIONS WHICH PLACE THIS NOTE FOR POWER AND EQUIPMENT | | | IN THE EGRESS CORRIDORS? | | | PLEASE ALSO CORRELATE WITH THE FIFTH FLOOR PLANS AS | | | THIS SEEMS TO BE THE LOCATION(S) IN WHICH EQUIPMENT | | | WILL BE INSTALLED IN A ELEVATOR EQUIPMENT CLOSET. | | | PLEASE SEE PREVIOUS NOTES WITH RESPECT TO CIRCUITING | | | FOR BRANCH CIRCUITS WHICH COULD NOT BE LOCATED AS | | | REQUIRED. | | | NEC 620 | | | FBC ADMIN SECTION 104.2.1.2 FOR CLARIFICATION. | | | | | | 20) NOTE: PLEASE INDICATE CLARIFY LOCATION OF THE PANEL | | | "P". | | | 110.26, 240.24, 408.7 ETC | | | | | | | | | *** PLEASE KNOW THAT THERE MAY BE NEW COMMENTS ON THE | | | NEXT REVIEW DUE TO INFORMATION NOT SUBMITTED OR | | | COORDINATION OF PLANS/INFORMATION SUBMITTED FOR REVIEW | | | | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER REVIEWER(S) WHICH | | | MAY HAVE AN AFFECT ON ELECTRICAL PLANS. | | | | | | ** PLEASE KNOW, A TYPE WRITTEN RESPONSE LETTER FROM | | | DESIGN PROFESSIONAL(S) FOR EACH COMMENT ON HOW/WHERE | | | CORRECTIONS ARE MADE OR IF COMMENTS ON REVIEW WILL HELP | | | IN EXPEDITING THE PLAN REVIEW PROCESS. THIS WAS DONE, | | | AND SHOULD BE DONE FOR THIS REVIEW AS WELL. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | 2007-01-01 09:16:54 | 2007-01-01 09:16:54 | | | IN ELEC FOR REVIEW, IN PROGRESS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-12-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-26 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-25 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2005-12-26 00:00:00 | REVIEW IN PROGRESS | | | ************ UNSAT ************ | | | | | | COURTNEY LAKES | | | N. CONGRESS. | | | | | | | | | 1)NOTE: PLEASE SUBMIT COMPLETED PLANS | | | BOUND TOGETHER IN APPROPRIATE FASHION. | | | PLEASE SEE ALL SHEETS WERE SUBMITTED | | | LOOSELY AND NOT IN BOUND STES. | | | | | | 2)NOTE: PLEASE BE SURE ALL PLANS ARE | | | SIGNED, DATED AND SEALED BY ALL DESIGN PROFESSIONALS AS | | | REQUIRED UDNER FS | | | 481.221 AND 471.025. | | | (PLEASE SEE A-SHEETS, ONLY SIGNED). | | | | | | 3)NOTE: PLEASE BE SURE TO CORRECT THE | | | CURRENT NEC/ NFPA-70 IN EFFECT. | | | PLEASE KNOW, AS OF JULY 1ST, 2003 THE | | | STATE OF FLORIDA ADOPTED THE 2002 | | | NFPA-70 (NEC). PLANS REFERENCE 1999. | | | PLEASE SEE SOME ELECTRICAL COMMENTS | | | WHICH WILL AFFECT THIS. | | | PLEASE SEE NEXT COMMENT WITH RESPECT TO | | | PERMITS APPLIED FOR UNDER THE 2001 FBC | | | BEFORE OCT 1ST, 2005 AND PERMITS ON OCT | | | 1ST, 2005. | | | | | | 4)NOTE: PLEASESEE THAT THREE SEPARATE | | | PERMIT APPLICATIONS WERE SUBMITTED AND | | | NOTED FOR BLDG'S 1,2 AND 3, HOWEVER | | | PLANS SHOWS BLDG TYPES 1.2&3 STRUCTUALLY | | | ONLY ONE BUILDING. | | | PLEASE SEE PERMIT APPLICATIONS ALL | | | REFLECT THIS ONE 450 UNIT BLDG. | | | PLEASE SEE THIS CONTRADICTS THE "PHASING | | | PLAN" SUBMITTED ON A1.04 AS THIS PHASING | | | PLAN INDICATES WORK ON BLDGS 4 AND 5 | | | BEFORE COMPLETION OF BLDGS 1, 2 AND 3. | | | PLEASE SEE COMMENTS FROM BLDG, FIRE AND | | | OTHER REVIEWERS, ASCERTIFICATES OF | | | OCCUPANCY(CO'S) FOR THESE CAN NOT BE | | | GRANTED IN THIS ORDER AS THE FIRST | | | "STRUCTURED BLDG"(1,2&3) WOULD NOT BE | | | COMPLETE. | | | PLEASE ALSO SEE COMMENTS WITH RESPECT TO "TEMPORARY | | | CO'S" WHICH MAY ALLOW | | | OCCUPANCY OF SOME PARTS OF BLDGS, | | | HOWEVER THESE TCO'S ARE ONLY GOOD FOR 30 | | | DAYS AND A MAX OF 3 TCO'S MAY ONLY BE | | | GRANTED BY THE BLDG OFFICAL. | | | PLEASE KNOW, IN ANY CASE, ALL LIFE | | | SAFTEY, FIRE PROTECTION SYSTEMS, FIRE | | | SPRINKLERS (FULLY CHARGED),ELECTRICAL | | | SYSTEMS ETC SHALL BE COMPLETE IN THE | | | BASE BLDG FOR BLDG TYPE 1, 2& 3 BEFORE A | | | TCO,/CO CAN BE GRANTED. | | | | | | ************************************* | | | ALSO NOTED THAT BLDG'S TYPE 4 AND 5 | | | WHICH ARE SEPARATE STRUCTURES AND | | | INDEPENDANT OF EACH OTHER WERE NOT | | | SUBMITTED FOR PERMIT. | | | PLEASE SEE ALL PERMITS SUBMITTED AFTER | | | OCT. 1ST, 2005 SHALL FALL UNDER THE | | | 2004 FBC, WITH ALL OTHER CODES ADOPTED | | | BY SAID CODE AND STATE OF FLORIDA. | | | | | | ************************************ | | | PLEASE SEE COMMENTS FROM OTHER | | | REVIEWER(S) WITH RESPECT TO THIS. | | | | | | ************************************* | | | PLEASE ALSO SEE NEXT COMMENT WITH | | | RESPECT TO THE MAINS, SERVICES, AND | | | METER RMS AS PROPOSED. | | | ** SEE ALL NOTES FROM ALL REVIEWERS | | | WHICH MAY ALSO AFFECT THIS SEQUENCE OF CONSTUCTION. | | | | | | 5)NOTE: PLEASE SEE METER RMS AS SHOWN | | | WOULD BE OK, HOWEVER STRUCTURE AS SHOWN | | | FOR BLDG TYPE 1,2 AND 3 (ONE BLDG) WOULD | | | REQUIRE MAINS TO BE GROUPED. | | | 90.4,230.2,230.70,230.72,230.76,230.79 | | | ETC. | | | BLDG'S LARGE ENOUGH TO CONTAIN MORE THAN | | | ONE SERVICE AT SEPARATE LOCATIONS SHALL | | | BE DIVIDED INTO SECTIONS AND SHALL HAVE | | | THOSE SECTIONS DIVIDED BY "FIRE WALLS". | | | PLEASE SEE FBC FOR DEFINITION OF "FIRE | | | WALLS". | | | PLEASE KNOW, STRUCTURE CONSTRUCTED AS | | | SHOWN IN PLANS, WOULD REQUIRE MAIN | | | DISCONNECTS GROUPED, WHICH WOULD THEN | | | IN-TURN FEED METER ROOMS. | | | OTHER DESIGN CHANGES IN THE "ONE BLDG" | | | MAY ALSO PERMIT INDIVIDUAL SERVICES. | | | PLEASE SEE BLDG TYPE #4 AND #5 ARE SHOWN | | | AS SEPARATE BLDGS WITH STAND ALONE | | | SERVICES AND ALL MAINS ARE GROUPED. | | | PLEASE KNOW THAT BLDGS 4 AND 5 WILL HAVE | | | REVIEWS DONE UNDER THOSE PERMIT | | | APPLICATIONS. | | | ** PLEASE SEE SOME OF THESE COMMENTS | | | WOULD ALSO APPLY. | | | | | | 6)NOTE: PLEASE COMPLETE ALL CIRCUITING | | | ON PLANS IN ORDER TO REVIEW CODE | | | COMPLIANCEFOR AREAS OF UNITS AND | | | COMMON AREAS. | | | | | | 7)NOTE: PLEASE PROVIDE ROOM AND AREA | | | DESIGNATIONS ON PLANS, INCLUSIVE OF ALL | | | UNITS AND COMMON AREAS. | | | REVIEW FOR SOME CODE COMPLIANCE ITEMS | | | CAN NOT BE DONE AT THIS TIME. | | | | | | 8)NOTE: PLEASE PROVIDE COMPLETE | | | PHOTOMETRICS FOR ALL COMMON AREAS, | | | GARAGE AREA,COMMON AREA CORRIDORS, | | | STAIR TOWERS ETC. | | | PLEASE SEE 2003 NFPA-101 7.8.1.3 AND | | | 7.9.2 WHICH REQUIRES A MIN OF 10FT | | | CANDLES FOR STAIR TOWERS UNDER NORMAL | | | OPERATION AS WALK SURFACE AND A MIN OF | | | 1FT CANDLE AT WALK SURFACE UNDER | | | EMERGENCY CONDTIONS. PLEASE ALSO SEE | | | OTHER WALK AREAS, GARAGE, CORRIDORS ETC | | | AND THE MIN OF 1FT CANDLE. | | | **PLEASE SEE PALM BEACH COUNTY SECURITY | | | CODE ORDIANCE WITH RESPECT TO MIN DESIGN | | | OF PARKING LOT LIGHTING LEVELS UNDER | | | NORMAL CONDITIONS. (ONLY NOTED FOR | | | DESIGN)NOT REQUIRED. PLEASE SEE ANY | | | REQUIREMENTS FROM INS CARRIER WHICH | | | REQUIE A MIN LEVEL OF LIGHTING. | | | ** PLEASE SEE PHOTOMETRICS OR SITE PLAN | | | WAS NOT SUBMITTED FOR PROPOSED POOL | | | AREA. THE POOL STRUCTURE IS REQUIRED TO | | | BE UNDER A SEPARATE PERMIT. PLEASE KNOW, | | | THE PHOTOMETRICS FOR POOL AREA WILL BE | | | REQUIRED AND WILL ALSO BE REQUIRED TO BE | | | REVIEWED AND STAMPED BY THE PALM BEACH | | | COUNTY HEALTH DEPT FOR ANY PROPOSED | | | NIGHT-TIME SWIMMING. | | | | | | 7)NOTE: PLEASE SEE NO "ELECTRICAL | | | SITE-PLAN" WAS SUBMITTED FOR ANY SITE | | | LIGHTING, LANDSCAPE LIGHTING ETC. | | | PLEASE KNOW, IF NOT SUBMITTED UNDER THIS | | | PERMIT AND VALUES ADJUSTED ACCORDINGLY, | | | SSEPARATE PERMIT , PLANS AND FEES WILL | | | BE REQUIRED FOR ALL SITE LIGHTING, | | | LANDSCAPE LIGHTING WORK. | | | ** ALSO NOTE: IN THAT COMPLETE WIND | | | LOADING CALCULATIONS FOR LT POLES | | | INCLUSIVE FO THE ATTACHMENT OF LT | | | FIXTURES WILL BE REQUIRED TO BE | | | SUBMITTED WITH PLANS AND PERMIT | | | APPLICATION FOR REVIEW. | | | | | | 8)NOTE: PLEASE INCLUDE AN EMERGENCY | | | BATTERY BACK UP LT OF SOME SORT IN ALL | | | ELECTRICAL ROOMS, FIRE PUMP ROOM, | | | ELEVATOR MACHINE RMS. SOME ARE SHOWN, | | | BUT NOT ALL. | | | 7.8,7.9,700.16 ETC | | | | | | 9)NOTE: PLEASE SEE 620.23, AND 620.24 | | | FOR REQUIRED DEDICATED BRANCH CIRCUITS | | | FOR ELEVATOR PITS, AND ELEVATOR MACHINE RMS/EQUIPMENT | | | AREAS. | | | PLEASE ADJUST HOUSE PANELS AS NEEDED. | | | | | | 10)NOTE: PLEASE SEE ELECTRICAL RISER | | | SHOULD "NOTE" FIRE PUMP AS DIESEL AS | | | NOTED ON FP SHEETS. | | | PLEASE SUBMIT ALL MANUAFCTURES SPEC/CUT | | | SHEETS FOR FIRE PUMP CONTROLLER AS | | | REVIEW FOR CODE COMPLIANCE UNDER 2002 | | | NFPA-20 IS REQUIRED. | | | PLEASE ALSO SUBMIT ALL MANUFACTURES | | | SPECS/CUT SHEETS FOR FUEL TANK. | | | PLEASE SEE NFPA-20 9.6.2.2 AS THE FUEL | | | CAPACITY IS REQUIRED TO BE SIZED BASE ON | | | THE 100% RATED LOAD FOR A MIN OF 8HRS, | | | OT TIME SO DETERMIND BY THE FIRE | | | MARSHAL'S OFFICE DEPENDING ON OCCUPANCY. | | | FUEL SYSTEMS WILL BE UNDER OTHER TRADE | | | REVIEW(S). (FIRE AND MECH). | | | | | | 11)NOTE: PLEASE INCLUDE ALL MIN | | | CONDUCTOR SIZES ON ALL PANELS,UNITS AND | | | HOUSE PANELS. REVIEW FOR THESE ITEMS OF | | | CODE COMPLIANCE CAN NOT BE DONE AT THIS | | | TIME. 310.16,240.4,215.5 | | | | | | 12)NOTE: PLEASE SEE GARAGE/HOUSE | | | LIGHTING BEING INDICATED ON 30A AND 50A | | | CIRCUITS. | | | PLEASE SEE CODE DOES LIMIT THE OCP FOR | | | UNIT FIXTURES FOR PROTECTION OF FIXTURES | | | ON A BRANCH CIRCUIT. | | | PLEASE ADJUST CIRCUITING AS NEEDED. | | | PLEASE ALSO SEE A FIXTURE SCHEDULE | | | CONTAINING WATTAGES, VOLTAGES ETC WAS | | | NOT SUBMITTED. | | | PLEASE VERIFY IF THESE UNIT FIXTURES ARE | | | RATED TO HAVE OCP AT ABOVE MENTIONED. | | | 240.4, 310.16 ETC | | | | | | 13)NOTE: PLEASE CORRELATE ALL OCP | | | DEVICES FOR UNITS AND FEEDERS BEING | | | LISTED IN "RISER NOTES". | | | PLEASE SEE SOME FEEDERS SHOWN AS #4'S ON | | | 125A BREAKER? | | | SEE 310.16,240.4 | | | PLEASE SEE OCP FOR ALL UNITS IS LISTED | | | AS 125A'S. | | | SEE NEXT COMMENT. | | | | | | 14)NOTE: PLEASE SEE MAX OCP TO BE SIZED | | | FOR PANELS/EQUIPMNET BEING FED BY SAID | | | OCP. | | | PLEASE SEE MANY UNIT PANELS ARE SHOWN AS | | | 100A MLO, WITH 125A OCP AS LISTED ON | | | RISER ETC. | | | PLEASE ALSO SEE RISER NOTE #4 WHICH | | | INDICATES 125A 2-POLE ETC, HOWEVER | | | PLEASE SEE RISER AS THIS NOTE #4 COULD | | | NOT BE LOCATED. (APPEARS TO BE | | | MISPRINTED FOR "NOTE#7" ON RISER) | | | 240.4,408,310.16,215.5 ETC. | | | | | | 15)NOTE: PLEASE SEE 16.26 AND 16.27 | | | WHICH CONTAIN THE SAME EXACT "HOUSE | | | PANELS" ?? H1, H1A , H2, AND H2A. | | | PLEASE SEE SHEET 16.27 MAY BE DELETED IF | | | PANELSCHEDULES FOR "CA" AND"CB" ARE | | | MOVED TO 16.26. | | | | | | 16)NOTE: PLEASE CORRELATE LOADS SHOWN | | | FOR H1A WITH LOAD SHOWN ON H1. | | | THIS DOES NOT MATCH. | | | | | | 17)NOTE: PLEASE CORRELATE LOADS ON PANEL | | | H2A WITH LOADS SHOWN ON H2> | | | THESE ALSO DO NOT MATCH. | | | | | | 18)NOTE: PLEASE SEE THESE SHEETS ALSO | | | REFERENCE "ARC FAULT" PROTECTION FROM | | | THE 1999 NEC, WHICH ONLY REQUIRED | | | PROTECTION OF RECEPTS. | | | PLEASE SEE 2002 NEC WHICH REQUIRES | | | PROTECTION FOR ALL "OUTLETS" IN BEDRMS. | | | THIS IS INCLUSIVE OF RECEPTS, LTS, FANS, | | | SMOKE DETECTORS ETC. | | | PLEASE SEE NOTE ON UNIT PLANS AND | | | ADJUST. | | | | | | 19)NOTE: PLEASE CORRELATE LOADS , UNITS, | | | PANELS, AND BUILDING/METER LOAD | | | CALCULATIONS: | | | A) PLEASE SEE PANEL SCHEDULE/LOAD | | | CALCULATIONS FOR UNIT "B-3" SHOWN ON | | | 16.26, HOWEVER THIS UNIT TYPE OR LOADS | | | COULD NOT BE LOCATED ON BLDG LOAD | | | CALCULATIONS ON 16.25? | | | B)PLEASE ALSO SEE THE SAME COMMENT ABOVE | | | FOR UNIT "C-2" WHICH IS ALSO SHOWN ON | | | 16.26 BUT NOT IN CALCS ON 16.25?? | | | ** PLEASE ADJUST ALL AS NEEDED. | | | | | | 20)NOTE: PLEASE INCLUDE THE REQUIRED | | | FOOTER STEEL ON THE GROUNDING ELECTRODE | | | RISER DETAIL. | | | PLEASE ALSO SHOW ON RISER. | | | 250.50. | | | | | | 21)NOTE: PLEASE PROVIDE A DETAIL/NOTE | | | FOR ALL RACEWAY SEALS AS REQUIRED PER | | | 230.8 | | | | | | 22)NOTE: PLEASE SEE RISER WHICH SHOWS A | | | POOL PANEL BEING FED FROM PANEL "CA", | | | HOWEVER PANEL "CA" , DOES NOT SHOW SUCH | | | PANEL. | | | 215.5 | | | | | | 23)NOTE: PLEASE PROVIDE "FUTURE" POOL | | | PANEL ON RISER AND PANEL SCHEDULE. | | | 215.5 | | | | | | 24)NOTE: PLEASE SEE RISER NOTE #12 WHICH | | | IS SHOWN FOR FEED FROM PANEL "CA" TO | | | PANEL "CB". THIS IS SHOWN AS 500MCM'S, | | | ALTHOUGH OCP ON CA IS ONLY SHOWN AS | | | 200A'S? THIS IS PERMITTED, HOWEVER THE | | | 200A DEVICE MAY NOT ACCEPT 500MCM'S. | | | 215.5 | | | | | | 25)NOTE: PLEASE SEE REDLINED ITEMS ON | | | PLANS FOR "EQUIPMENT GROUNDING | | | CONDUCTORS" BEING SHOWN BEFORE THE FIRST | | | MEANS OF DISCONNECT. | | | PLEASE SEE 250.6, 250.24. | | | PLEASE SEE HOUSE METER #2, SEE RISER | | | NOTE #12 AND #13 SHOWS AN "EQUIPMENT | | | GROUNDING" CONDUCTOR WHICH IS | | | PARALLELING THE NEUTRAL. | | | | | | 26)NOTE: PLEASE SEE MIN OCP FOR WATER | | | HEATERS TO BE SIZED AT 125%.424.13 | | | PLEASE SEE UNITS CONTAINING 5KW WH @ | | | 208V'S WOULD INCREASE THIS BRKR TO A | | | 2-P35A. PLEASE ALSO ADJUST ANY AWG PER 310.16,240.4 | | | | | | 27)NOTE: PLEASE SEE UNIT LOAD | | | CALCULATIONS SHOWS THE LOADS FOR A/C'S | | | AFTER THE PERMITTED DERATING, HOWEVER | | | PLEASE SHOWLOADS FOR THESE BEFORE | | | DERATING. | | | PLEASE BE SURE TO CORRELATE WITH LOADS | | | FOR COOLING AND HEAT ON MECHANICAL PLAN. | | | 215.5 | | | | | | 28)NOTE: SMOKE DETECTORS ARE REQUIRED | | | INSIDE AND OUTSIDE ALL SLEEPING ROOMS. | | | PLEASE SEE 2002 NFPA-72 11.5.3.1 | | | PLEASE ADJUST NOTE FOR SD'S ON PLANS AS | | | SD'S ARE REQUIRED 3' FROM BATH/KTICHEN | | | DOORS, 3' FROM SUPPLY AIR DIFFUSERS, 5' | | | FROM R/A GRILLES AND 20' FROM KITCHEN | | | COOKING APPLIANCES. W/ EXCEPTIONS FOR | | | DISTANCES FROM COOKING APPLIANCES. | | | (PHOTOELECTRIC AND RESETTING TYPE) | | | ** PLEASE SEE PRIVIOUS NOTES WITH | | | RESPECT TO ARC FAULT PROTECTION OF SD'S | | | AND CIRCUTING. | | | | | | 29)NOTE: PLEASE SEE ALL RECEPTS IN | | | CLUBHOUSE KITCHEN PER 210.8B3 WHICH | | | REQUIRES ALL 15- AND 20-AMPERE, 125-VOLT RECEPTACLES IN | | | NONDWELLING-TYPE KITCHENS | | | TO BE GFCI PROTECTED. THIS REQUIREMENT | | | APPLIES TO EACH AND EVERY 15- AND | | | 20-AMPERE, 125-VOLT KITCHEN RECEPTACLE, | | | WHETHER OR NOT THE RECEPTACLE SERVES | | | COUNTERTOP APPLIANCES. | | | | | | 30)NOTE: PLEASE SEE 700.12E FOR | | | CIRCUITING OF ALL EM/EXT LTS, WHICH | | | REQUIRES THE BRANCH CIRCUIT FEEDING THE | | | UNIT EQUIPMENT SHALL BE THE SAME BRANCH | | | CIRCUIT AS THAT SERVING THE NORMAL | | | LIGHTING IN THE AREA AND CONNECTED AHEAD | | | OF ANY LOCAL SWITCHES. | | | THIS IS NOTED ON SOME SHEETS, HOWEVER | | | CIRCUITING FOR THESE IS NOT SHOWN. | | | 215.5 | | | | | | 31)NOTE: PLEASE CLARIFY THE "CT" AS | | | LABLED ALONG KITCHEN RECEPTS. THIS | | | ABBREVIATION COULD NOT BE LOCATED ON | | | SYMBOL LEGEND? | | | | | | 32)NOTE: PLEASE SEE 210.52C1-C5 FOR | | | REQUIRED GFI RECEPTS ALONG KTICHEN | | | COUNTERSPACE. PLEASE SEE SOME ARE SHOWN | | | ON WHAT APPEARS TO BE A WALL ON THE | | | OTHER SIDE OF THE COUNTERSPACE. | | | PLEASE SEE B-2, B-4ETC. | | | PLEASE SEE OTHER WHICH ARE REQUIRED TO | | | BE WITHIN 2' OF THE END OF THE | | | COUNTERSPACE/FROM SINK EDGE ETC. | | | PLEASE SEE THESE AREAS REDLINED ON | | | SHEETS. | | | | | | 33)NOTE: PLEASE SEE WHAT APPEARS TO BE A | | | RECEPT LOCATED IN THE CLOTHES CLOSET FOR | | | PERHAPS A LV PLUG-IN TYPE TRANSFORMER? | | | PLEASE KNOW, THE ONLY LOCATION A RECEPT | | | IS PERMITTED IN A CLOTHES CLOSET FOR | | | THIS PURPOSE, MUST BE LOCATED DIRECTLY | | | ABOVE DOOR AWAY FROM COMBUSTIBLES. | | | MANY PLUG-IN TYPE TRANSFORMERS BECOME | | | VERY HOT AND HAVE MELTED OR CAUSED FIRES | | | IN THIS JURISTICTION. PLEASE KNOW, MANY | | | ITEMS IN A CLOTHES CLOSET ARE AN | | | ACCELERANT. | | | THESE RECEPTS MAY BE MOVED TO UTILITY RM | | | IS SO DESIRED. | | | 110.26, 240.24, 90.4 ETC | | | | | | 34)NOTE: PLEASE SEE RELDINED PLANS FOR | | | ANY RECEPTS WHICH MAY BE REQUIRED PER | | | 210.52 (A-2). MOST ALL SPACING IS OK. | | | | | | 35)NOTE: PLEASE MAKE NOTE FOR ALL MIN | | | FAIR HOUSING ACT REQUIREMENTS FOR DEVICE | | | HEIGHTS. | | | 24 CFR 100.205 | | | ** PLEASE KNOW, SOME REVIEW OF CODE | | | COMPLIANT ITEMS MAY NOT BE DONE AT THIS | | | TIME DUE TO SOME INFORMATION NOT ON | | | PLANS. | | | | | | ** PLEASE SEE ANY COMMENTS FROM OTHER | | | REVIEWER(S) WHICH MAY HAVE AN AFFETC ON | | | ELECTRICAL PLANS. | | | | | | ** PLEASE KNOW, A TYPE WRITTEN RESPONSE | | | LETTER FROM DESIGN PROFESSIONL(S) FOR | | | EACH COMMENT ON HOW/WHERE CORRECTIONS | | | ARE MADE OR IF COMMENTS ON REVIEW WILL | | | HELP IN EXPEDITING THE PLAN REVIEW | | | PROCESS. | | | | | | ** PLEASE KNOW THAT A MEETING TO GO OVER | | | FIRST COMMENTS FOR DESIGN/PHASING OF | | | BLDGWITH ALL REVIEWERS IS SUGGESTED | | | BEFORE PERHAPS SUBMITTING PLANS BACK FOR | | | REVIEW. | | | PLEASE KNOW, ALL REVIEWS AFTER THE 1ST | | | FREE "RE-SUB" IS SUBJECT TO A 10% RESUB | | | FEE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2005-12-25 00:00:00 | ONE ROLL IN ELECTRIC FOR REVIEW. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-09-28 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-09-28 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2007-09-28 14:19:55 | ****FAILED***** | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON CIVIL DRAWING THE EXACT MAILING | | | ADDRESS, BUILDING NAME, OR NUMBER, YOU TALKING ABOUT 3 | | | PERMITS, PLEASE IDENTIFY EACH BUILDING ON THE DRAWING. | | | 3.PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 4.PLEASE SHOW FINISH FLOOR ELEVATION ON DRAWING . | | | PLEASE EXPLAIN IN DETERMINING FIRST FLOOR ELEVATION, | | | PLEASE SHOW IN YOUR CALCULATION THAT YOU CONSIDERED | | | CENTER LINE OF ROAD , FLOOD ZONE OF THIS SITE,& 5,10, | | | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST | | | FLOOR ELEVATION, PLEASE SHOW ALL THESE IN YOUR STORM | | | WATER CALS.PLEASE ALSO SHOW ON DRAWINGS THE MAXIMUN | | | AND MINIMUM PARKING LOT ELEVATIONS. | | | | | | 5. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE | | | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL | | | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, | | | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE | | | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED | | | IN STORM WATER QUALITY CALCULATIONS. | | | 6. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE | | | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM | | | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE | | | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR | | | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET | | | DETENTION AREAS IN STORM WATER CALS.AFTER CONTROL | | | STRUCTURE WHERE STORM WATER GOES?? | | | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN. | | | 8. PLEASE RESUBMIT A COPY OF SFWMD PERMIT,, & GEO TECH | | | REPORT,STORM WATER CALS MUST BE APPROVED FROM 1000 | | | 45TH STREET ENGINEERING SERVICES. | | | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | 10. PLEASE KEEP SEPARATE CIVIL DRAWINGS SO I CAN REVIEW | | | QUICK. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2007-01-19 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-01-19 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-01-19 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2007-01-19 09:56:42 | PLEASE SUBMIT CIVIL PLANS FOR OUR REVIEW ALON WITH A | | | COPY OF SFWMD PERMIT, GEO TECH REPORT, WATER QUALITY | | | STORM WATER CALCULATIONS. | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2005-10-31 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-10-31 |
Time |
10:51 |
Rev Time |
0.50 |
| Received By |
mamini |
Date |
2005-10-31 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2005-10-31 00:00:00 | FAILED: | | | | | | 1. PLEASE SUBMIT CIVIL PLANS FOR OUR | | | REVIEW AND APPROVAL.NOTE THAT CIVIL | | | PLANS FOR THIS WERE REVIEWED UNDER OLD | | | PERMIT APPLICATIONS # 04021308,04021305, | | | 04021300 WHICH EXPIRED.COPY OF THE | | | REVIEW NOTES INCLUDED FOR YOUR USE. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2007-11-07 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-11-07 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-11-07 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2007-11-07 14:32:47 | ***DENIED*** | | | | | | COMMENTS FROM FIRST REVIEW HAVE NOT BEEN ADDRESSED. | | | RESPONSE LETTER INDICATES COMMENT RESPONSES BELOW, | | | HOWEVER NONE WERE PROVIDED. PLEASE REFER TO PAGE 35 OF | | | RESPONSE LETTER. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-02-27 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-02-27 |
Time |
15:20 |
Sent To |
|
|
| Notes |
| 2007-02-27 15:30:33 | ***DENIED*** | | | | | | IN ORDER TO HELP EXPEDITE THE PLAN REVIEW PROCESS, | | | PLEASE SEE THE FOLLOWING: | | | | | | 1) PLEASE REFER TO THE FIRST FIRE REVIEW COMMENTS. MANY | | | COMMENTS WERE ANSWERED OR ADDRESSED WITH COMMENT NOTED. | | | THIS DOES NOT DEMONSTRATE THAT COMPLIANCE WILL BE MET. | | | IT WOULD BE HELPFUL IF THE CHANGE OR ADDED NOTE IS | | | CLEARLY SHOWN ON DRAWINGS, AND THE CORRECT SHEET NUMBER | | | IS INDICATED. SOME RESPONSES WERE FOUND ON SHEETS THAT | | | WERE DIFFERENT FROM WHAT WAS INDICATED IN THE RESPONSE | | | LETTER. FOR EXAMPLE, COMMENT #1 INDICATES THAT | | | REFERENCE HAS BEEN ADDED TO FP13.17, BUT WAS ACTUALLY | | | FOUND ON A 1.02. PLEASE KNOW THAT IT IS UNDERSTOOD THAT | | | SOME COMMENTS MAY BE ACKNOWLEDGED, BUT SHOULD BE SHOWN | | | ON PLANS TO ELLIMINATE CONFUSION IN THE FUTURE DURING | | | THE INSPECTION PROCESS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW(561) 805-6722 | | | FIRE PREVENTION(561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-12-27 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-12-27 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2005-12-27 00:00:00 | ******DENIED****** | | | | | | 1) NFPA 101 AND NFPA 1, 2003 EDITION | | | SHALL BE REFERENCED. | | | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | | ARE REQUIRED FOR FIRE SPRINKLER SYSTEM | | | WHICH SHALL BE UL CERTIFIED FOR CENTRAL | | | STATION SERVICE. | | | | | | 3) PLEASE NOTE THAT INTENDED SCOPE OF | | | WORK FOR THIS PROJECT IN RELATION TO THE | | | PERMIT APPLICATIONS IS CONFUSING. | | | | | | 4) WHENS PLANS ARE RESUBMITTED, PLEASE | | | ASSURE THAT ALL SHEETS ARE BOUND | | | TOGETHER AND ORGANIZED. | | | | | | 5) CONSTRUCTION, ALTERATION AND | | | DEMOLITION TO COMPLY WITH NFPA 241. | | | | | | 6) STAIRS ARE TO BE KEPT UP WITH | | | CONSTRUCTION. | | | | | | 7) TEMPORARY STANDPIPES ARE REQUIRED | | | WHEN THE BUILDING REACHES 3 STORIES OR | | | 30' IN HEIGHT. | | | | | | 8) IN REGARDS TO PHASING, PLEASE BE | | | ADVISED THAT ALL LIFE SAFETY COMPONENTS | | | MUST BE INSPECTED, TESTED AND APPROVED | | | PRIOR TO OCCUPANCY OF BUILDINGS. | | | | | | 9) PARKING AREAS MUST BE IN COMPLIANCE | | | WITH APPLICABLE BUILDING CODES AND NFPA | | | 88A. MINIMUM TWO HOUR SEPARATION TO | | | OTHER PARTS OF BUILDING IS REQUIRED. | | | | | | 10) WET FIRE HYDRANTS TO BE OPERATION | | | PRIOR TO, DURING AND AFTER CONSTRUCTION. | | | | | | 11) PLEASE NOTE THAT ALL LIFE SAFETY | | | EQUIPMENT, FIRE SPRINKLER AND FIRE ALARM | | | AND ALL OTHER BUILDING SERVICES SHALL BE | | | SEPARATE IF BUILDINGS MEET THE CRITERIA | | | FOR SEPARATE STRUCTURES. | | | | | | 12) ALL ACCESS ROADS SHALL BE AT LEAST | | | 20' IN CLEAR , UNOBSTRUCTED WIDTH FOR | | | EMERGENCY VEHICLES, AND SHALL MEET ALL | | | OTHER REQUIREMENTS OF NFPA 1. | | | | | | 13) PLEASE INDICATE ALL LOCATION OF FIRE | | | HYDRANTS. | | | | | | 14) NFPA 13, 2002 EDITION SHALL BE | | | REFERENCED. SHT. A5.01. | | | | | | 15) LOCKING KNOX BOX CAPS ARE REQUIRED | | | ON FIRE DEPARTMENT CONNECTIONS. | | | | | | 16) IN ADDITION TO ELECTRONIC SWITCHES, | | | THE DOUBLE CHECK DETECTOR ASSEMBLIES | | | SHALL BE SECURED WITH A CHAIN AND LOCK. | | | | | | 17) AS NOTED ON SHT, A5.02, FIRE | | | EXTINGUISHERS SHALL BE MOUNTED AT | | | DISTANCES TO SATISFY THE 75' TRAVEL | | | DISTANCE REQUIREMENT. | | | | | | 18) ALL DOORS SHALL SWING IN THE | | | DIRECTION OF TRAVEL WHEN SERVING AREAS | | | WITH OCCUPANT LOADS OF GREATER THAN 50. | | | | | | 19) ELEVATORS TO COMPLY WITH ASME A17.1. | | | | | | 20) PENETRATIONS INTO , AND OPENINGS | | | THROUGH STAIRWELLS SHALL BE LIMITED TO | | | AND IN COMPLIANCE WITH NFPA 101, SECTION | | | 7.1.3.2.1 (6). | | | | | | 21) PLEASE CLARIFY ALL EXIT DISCHARGING | | | FROM STAIRWELLS THAT LEAD DIRECTLY TO | | | THE OUTSIDE. | | | | | | 22) SOME ACHITECTUAL DRAWINGS SHOW | | | STAIRWELL DOORS, AND OTHERS DON'T.??? | | | | | | 23) THIS PERMIT APPLICATION PROCESS | | | ILLUSTRATES 3 BUILDINGS AND OTHER | | | BUILDINGS, 4&5 ARE SHOWN ON PLANS. | | | PLEASE CLARIFY. | | | | | | 24) PLEASE ILLUSTRATE THE TOTAL OCCUPANT | | | LOAD FOR THE CLUBHOUSE. | | | | | | 25) IN ADDITION TO THE ALREADY NOTED | | | REQUIREMENTS FOR ADDRESSING, PLEASE NOTE | | | THAT THE HEIGHT OF THE ADDRESS SHALL BE | | | AT LEAST 3" IN HEIGHT FOR RESIDENTIAL | | | BUILDINGS. | | | | | | 26) PLEASE REFER TO DOOR SCHEDULE AND | | | VERIFY CORRECT AMOUNT OF FIRE RATED | | | DOORS. DOORS SERVINGS AREAS WITH | | | OCCUPANT LOADS GREATER THAN 100 SHALL | | | HAVE PANIC HARDWARE. | | | | | | 27) FIRE PROTECTION SITE PLAN DOESN'T | | | APPEAR COMPLETE ON SHT FP13.01. | | | | | | 28) FIRE DEPARTMENT VALVES SHALL BE 2 | | | 1/2" TO 1 1/2" REDUCER WITH CHAINS. | | | | | | 29) MORE INFORMATION AND MANUFACTURER | | | SPEC SHEETS REQUIRED FOR FIRE PUMP AND | | | ASSOCIATED EQUIPMENT. | | | | | | 30) FIRE PROTECTION SHEETS DON'T SHOW | | | ANY FIRE SPRINKLER SYSTEM. ???? FIRE | | | SPRINKLER DESIGN AND LAY OUT MUST BE | | | ILLUSTRATED. | | | | | | 31) IF A FIRE HYDRANT FLOW TEST HASN'T | | | BEEN DONE WITHIN ONE YEAR, ANOTHER TEST | | | WILL BE REQUIRED FOR FIRE SPRINKLER | | | CALC. PLEASE CONTACT THE BUREAU OF FIRE | | | PREVENTION AT (561) 805-4724. | | | | | | 32) PLEASE INDICATE ALL SMOKE DETECTOR | | | LOCATIONS IN ACCORDANCE WITH NFPA 101, | | | SECTION 30.3.4.5. | | | | | | 33) EXIT LIGHTS TO BE MOUNTED AT | | | DISTANCES NOT TO EXCEED 100'. IT APPEARS | | | THAT MORE EXIT SIGNS ARE NEEDED IN | | | CORRIDORS. | | | | | | 34) FIRE ALARM SHALL BE CLASS A, STYLE D | | | OR FULLY ADDRESSABLE. | | | | | | 35) ARE SMOKE DETECTORS TIED INTO THE | | | FIRE ALARM SYSTEM PLANNED FOR CORRIDORS? | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
amckenzi |
Date |
2008-08-05 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
amckenzi |
Date |
2008-08-05 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2008-08-05 09:29:13 | TO EXTEND APPLICATION UNTIL 11/5/08 PER NKM/AMM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-14 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-14 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2007-09-07 16:15:56 | TO "COMM" BD#55/PLANS ON RACK--15 ROLLS | | 2007-08-14 14:25:47 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2006-11-29 |
Time |
19:31 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2006-11-29 |
Time |
19:31 |
Sent To |
|
|
| Notes |
| 2006-12-08 15:28:00 | TO "COMM" BD#41--3 APPL. PLANS ON RACK--7 ROLLS | | 2006-11-29 19:32:05 | WAITING FOR "COMM" BOARD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-31 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-31 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2006-08-31 00:00:00 | WAITING FOR "COMM" BD-ROLLS BY MIRELLE'S | | | CUBE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-03-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-10-03 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2005-10-12 00:00:00 | TO "COMM" BD#49/PLANS ON RACK | | 2005-10-03 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-10-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-10-04 |
Time |
18:15 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-09-25 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2007-10-04 17:42:29 | REVIEW #: 3 | | | ACTION: DENIED | | | | | | FBC 2001 CODE FAMILY | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | NOTE: THERE HAVE BEEN SIGNIFICANT CHANGES AS WELL AS | | | PAGES ADDED TO PLANS. THE LEVEL OF CHANNGES REQUIRES A | | | THOROUGH REVIEW OF MECHANICAL PLANS IN THEIR ENTIRETY. | | | ANY COMMENT FROM PREVIOUS REVIEWS NOT REPEATED IN THIS | | | REVIEW SHALL BE CONSIDERED TO HAVE BEEN ADEQUATELY | | | ADDRESSED. | | | | | | 1. M15.01 THRU M15.03: R/A JUMPERS FROM BEDROOMS ARE | | | NOT SIZED TO MEET THE BALANCED R/A EXCEPTIONS OF FBC,M | | | 601.4. ALL DROPS INTO A MASTER SUITE SHALL BE INCLUDED | | | PER EXCEPTION #3. THE MINIMUM SIZE JUMPER NEEDED FOR 7 | | | INCH AND 4 INCH ROUND DROPS IS 77 SQUARE INCHES. THE 9 | | | INCH ROUND SHOWN ON PLANS PROVIDES 63.6 SQUARE INCHES. | | | A MINIMUM 10 INCH ROUND DUCT IS REQUIRED TO MEET | | | EXCEPTION #1. UNLESS JUMPERS AND TRANSFERS ARE DESIGNED | | | TO MEET THESE EXCEPTIONS, A FIELD TEST WILL BE REQUIRED | | | AT FINAL INSPECTION TO VERIFY A DIFFERENTIAL PRESSURE | | | OF 0.01 IN. W.C. OR LESS ACROSS THE CLOSED DOOR IN | | | ACCORDANCE WITH THIS SECTION. | | | | | | 2. M15.01 THRU M15.03: NOTE 10 TABLE FOR TRANSFER | | | GRLLS, SIZES SHOWN ARE NOT IN COMPLIANCE WITH FBC,M | | | 601.4 EXCEPTION #2. SEE COMMENT 1 ABOVE FOR | | | REQUIREMENTS IF TRANSFERS ARE NOT DESIGNED TO MEET THE | | | EXCEPTIONS UNDER THIS SECTION. | | | | | | 3. M15.01 THRU M15.03: KEY NOTE #9, NO INFORMATION WAS | | | PROVIDED REGARDING DRYERS OR INSTALLATION INSTRUCTIONS | | | AS STATED IN THE NOTE. PROVIDE INFORMATION NEEDED TO | | | SHOW COMPLIANCE WITH FBC,M 501.4 AND KEY NOTE #9. | | | | | | 4. M15.01: THE CONFIGURATION OF THE AC CLOSET IN | | | APARTMENT A3 IS DIFFERENT FROM THE TYPICAL MOUNTING | | | DETAIL SHOWN ON M15.22. PROVIDE DETAIL FOR THIS | | | INSTALLATION SHOWING HOW DUCTED RETURN TO GRILL (SEE | | | NOTE 6 ON M15.01) WILL WORK WITH A WATER HEATER UNDER | | | THE AHU. ALSO, SHOW HOW O.A. DUCT IS TO TERMINATE IN | | | CLOSET. | | | | | | 5. M15.01 THRU M15.03: ALL APARTMENTS EXCEPT A3 CALL | | | FOR FULLY LOUVERED DOORS ON A/C CLOSETS FOR RETURN AIR. | | | ARCHITECTURAL FLOOR PLANS A5.50 THRU A5.53 SHOW DOORS | | | AS U02 AND U-18. DOOR SCHEDULE ON A-9.02 SHOWS THESE TO | | | BE "J" TYPE DOORS, WHICH ARE SOLID 6-PANEL DOORS. | | | COORDINATE PLANS AND SHOW HOW AIR IS TO BE RETURNED TO | | | A/C CLOSETS. FBC,M 601.4 | | | | | | 6. M15.04: FIRST AND SECOND FLOOR AREAS, BASED ON LIFE | | | SAFETY PLANS A1.20 AND A1.21 ALONG WITH FLOOR PLANS | | | A5.07 AND A5.71 THERE ARE NUMEROUS LOATIONS WHERE DUCTS | | | ARE PENETRATING RATED WALL ASSEMBLIES. SHOW OPENING | | | PROTECTIVES AT ALL LOCATIONS WHERE DUCTS PENETRATE | | | RATED ASSEMBLIES. BE SURE TO COOORDINATE WITH | | | ARCHITECTURAL PLAND. FBC,M 607.1.2 AND 607.6 | | | | | | 7. M15.05 THRU M15.08 AND M15.11: KEY NOTE #1 CALLS FOR | | | 3/4 INCH PVC FROM EACH AHU TO CONDENSATE RISER. PVC | | | SHALL NOT BE LOCATED IN A/C CLOSETS USED AS PLENUMS PER | | | FBC,M 602.2.1. ALSO, CONDENSATE LINES AS SHOWN ON PLANS | | | WILL REQUIRE A SIGNIFICANT CHANGE IN ELEVATION TO | | | MAINTAIN A UNIFORM ALIGNMENT AND SLOPE IN ACCORDANCE | | | WITH FBC,M 307.2.2 DUE TO THE LONG HORIZONTAL RUNS | | | SHOWN IN GARAGE AREA. PROVIDE AN ELEVATION VIEW DETAIL | | | SHOWING THE FEASIBILITY OF THIS CONFIGURATION WHILE | | | TAKING INTO ACCOUNT STRUCTURAL ELEMENTS AND REQUIRED | | | CLEARANCES IN THE GARAGE. THE AREA CHOSEN FOR THIS | | | DETAIL SHOULD INCORPORATE A "WORST CASE" CONDITION. FBC | | | 104.2.1.2 | | | | | | 8. M15.22: CONDENSATE TRAP DETAIL FOR NON-DUCTED RETURN | | | UNITS, THE SECONDARY DRAIN LINE FROM THE AUXILIARY | | | DRAIN PAN SHALL NOT BE CONNECTED TO THE PRIMARY | | | CONDENSATE RISER. A SEPARATE DRAIN LINE SHALL EXTEND | | | FROM THE PAN TO A CONSPICUOUS POINT AND SERVE AS AN | | | ALARM WHICH INDICATES THAT THE PRIMARY DRAIN IS | | | RESTRICTED.AS AN ALTERNATIVE TO A SEPARATE DRAIN | | | LINE, AN APPROVED WATER LEVEL DETECTOR OR FLOAT SWITCH | | | DEVICE SHALL BE USED TO CONTROL OVERFLOW BY | | | AUTOMATICALLY SHUTTING DOWN THE EQUIPMENT OR APPLIANCE | | | THAT PRODUCES THE CONDENSATE. THE FLOAT SWITCH ON THE | | | SECONDARY DRAIN OUTLET AT THE AHU MAY BE INSTALLED | | | (ALTHOUGH IT'S NOT NECESSARY) BUT IT CAN NOT REPLACE | | | THE SEPARATE SECONDARY DRAIN LINE OR THE FLOAT SWITCH | | | REQUIRED ON THE AUXILIARY DRAIN PAN. THE FLOAT SWITCH | | | ON THE SECONDARY DRAIN OUTLET AT THE AHU IS ACCEPTABLE | | | AS OVERFLOW PROTECTION ONLY ON THE DUCTED RETURN UNITS | | | WHERE AN AUXILIARY DRAIN PAN CAN NOT BE INSTALLED UNDER | | | THE AHU. FBC,M 307.2.3 AND 307.2.4 | | | | | | 9. M15.22: DUCT SUPPORT DETAIL INDICATES 1/2 INCH WIDE | | | 22GA SUPPORTS ON FLEX DUCT. THE MATERIAL SUPPORTING | | | FLEX DUCT SHALL NOT BE LESS THAN 1 1/2 INCHES WIDE. | | | FBC,M 603.5.6.6(6). | | | | | | 10. M15.22: CONDENSING UNIT DETAIL CALLS FOR 1/4 INCH | | | CABLES TIED TO THE CONDENSER AND THE BEAM WITH 3/8 INCH | | | LAG BOLTS. LAG BOLTS ARE FOR USE IN WOOD. PLEASE | | | SPECIFY A FASTENER WHICH IS APPROPRIATE FOR THIS | | | APPLICATION. ALSO, INDICATE ON PLANS THE WIND SPEED TO | | | WHICH THIS CONNECTION DETAIL IS DESIGNED. FBC,M 301.13 | | | AND FBC CH.16 | | | | | | 11. M15.22: TYPICAL AHU DETAIL, PROVIDE MANUAL VOLUME | | | DAMPER AT OUTDOOR AIR DUCT IN CLOSET PER FBC | | | 13-409.1.ABCD.2. | | | | | | 12. M15.23: PROVIDE OUTDOOR AIR CALCULATIONS FOR | | | DWELLING UNITS IN ACCORDANCE WITH FBC,M TABLE 403.3. | | | | | | 13. M15.21: FIRE PUMP ROOM, PROVIDE SUBMITTAL AND | | | INSTALLATION DETAIL FOR THE DIESEL STORAGE TANK. ALSO, | | | PROVIDE DETAIL FOR THE DIESEL ENGINE EXHAUST WITH | | | DISCHARGE LOCATION. STATIONARY LIQUID FUELED INTERNAL | | | COMBUSTION ENGINES, INCLUDING FUEL STORAGE AND PIPING | | | SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 37-94. SEE | | | FBC,M 915.1 AND 915.2. | | | | | | 14: ENERGY: THERE WERE TWO DIFFERENT SETS OF | | | CALCULATIONS SUBMITTED. FORM 400A-2004 V2.5 IS NOT | | | VALID AS THIS PROJECT IS UNDER THE 2001 FBC. THE 2004 | | | FORM IS DISREGARDED AND THE 2001 FORM IS BEING REVIEWED | | | FOR CODE COMPLIANCE. FBC 13-400.3.A. | | | | | | 15. ENERGY: SEVERAL ITEMS LISTED ON THE INPUT DATA | | | REPORT DO NOT CORRELATE WITH WHAT IS SHOWN ON PLANS. | | | EXAMPLE: THE REPORT INDICATES EXTERIOR WALL ASSEMBLES | | | WITH R-VALUE OF 11.94. THE WALL AS DESCRIBED IN THE | | | REPORT IS NOT SHOWN ON ARCHITECTURAL PLANS. THE | | | INFORMATION USED IN THE INPUT DATA REPORT SHALLL | | | CORRELATE WITH PLANS. PLEASE VERIFY ALL ASSEMBLIES, | | | R-VALUES, U-FACTORS AND INFILTRATION RATES ARE IN | | | COMPLIANCE AND CORRESPOND WITH WHAT IS ON ARCHITECTURAL | | | PLANS. FBC 13-400.3.A | | | | | | 16. ENERGY: COOLING LOAD CALCS, DATA USED TO PERFORM | | | COOLING LOAD CALCULATIONS AS SHOWN ON THE SYSTEM SIZING | | | SUMMARY DO NOT MATCH THE VALUES SHOWN ON PLAN. EXAMPLE: | | | AHU CH-3 ON SUMMARY SHOWS 120 CFM OF OUTDOOR AIR. | | | EQUIPMENT SCHEDULEON M15.23 SHOWS 200 CFM, PLEASE | | | CORRELATE PLANS AND CALCULATIONS. FBC 13-407.1.ABCD.1 | | | | | | 17. ENERGY: PROVIDE AUTOMATIC SETBACK OR SHUTDOWN | | | CONTROLS IN ACCORDANCE WITH FBC 13-407.1.ABCD.2.4.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
|
Date |
2006-12-21 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-12-21 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-12-21 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2006-12-21 15:18:48 | DENIED:2001 FLORIDA BUILDING CODE | | | | | | BUILDING #1:PLEASE NOTE, PAGES HAVE CHANGED SINCE | | | PREVIOUS REVIEW DATED 1-31-06 | | | | | | RESPONSE TO COMMENT 1:RESPONSE INDICATES VENTILATION | | | CALCULATIONS ON SHEET M15.23. PLAN SHEET M15.23 IS | | | WAS NOT SUBMITTED FOR REVIEW, BUT THE CALCULATION DOES | | | APPEAR ON PLAN SHEET M15.07,CALCULATIONS WERE NOT | | | GIVEN THE THE UNITS. | | | | | | RESPONSE TO COMMENT 2:OKAY | | | | | | RESPONSE TO COMMENT 3:RESPONSE INDICATES THE AHU | | | CLOSET DOOR WAS CHANGED ON THE DOOR SCHEDULE A9.02 TO A | | | NON-COMUSTIBLE DOOR.THIS IS NOT THE CASE, THE DOOR | | | SCHEDULE INDICATES A WOOD DOOR.PLEASE ALSO NOTE ON | | | PLAN SHEET M15.01, M15.02, & M15.03KEY NOTE #11 | | | INDICATES A "FULL HEIGHT LOUVERED DOOR" WHICH IS NOT | | | REFLECTED ON THE DOOR SCHEDULE.PLEASE CORRELATE. | | | PLEASE ALSO NOTE, THE CONDENSATE LINE SHALL ALSO BE OF | | | NON-COMBUSTIBLE MATERIAL. | | | | | | RESPONSE TO COMMENT 4:RESPONSE INDICATES CLEARANCE | | | AROUND THE AHU EXCEEDS THE MINIMUM OF 4" AS REQUIRED IN | | | 2001 FMC 603.1.3.THIS NOT WHAT IS DEPICTED IN THE | | | DETAIL OF THE AHU MOUNTING DETAIL ON PLAN SHEET M15.09. | | | PLEASE REVISE PLAN TO REFLECT PROPER CLEARANCE.PLEASE | | | ALSO NOTE THE AFOREMENTIONED DETAIL SHOWS OUTSIDE AIR | | | DUCT.THIS IS NOT INDICATED ON ANY OF THE PLANS, | | | PLEASE PROVIDE DUCT SIZE, LAYOUT, MATERIAL AND INTAKE. | | | | | | RESPONSE TO COMMENT 5:RESPONSE INDICATES "CONDENSATE | | | TRAP DETAIL" ON SHEET M15.22.SHEET M15.22 WAS NOT | | | SUBMITTED.PLEASE NOTE, THE ORIGINAL COMMENT REQUESTED | | | INFORMATION ON THE AUXILIARY DRAIN PAN & OVERFLOW | | | PROTECTION AS REQUIRED IN 2001 FMC 307.2.3.COMMENT | | | WAS NOT ADDRESSED. | | | | | | RESPONSE TO COMMENT 6:RESPONSE STATES "TYPICAL | | | CONDENSING UNIT INSTALLATION DETAIL" ON SHEET M15.22. | | | THIS SHEET WAS NOT SUBMITTED. | | | | | | RESPONSE TO COMMENT 7 ALSO REFERS TO SHEET M15.22 WHICH | | | WAS NOT SUBMITTED FOR REVIEW. | | | | | | RESPONSE TO COMMENT 8:OKAY | | | | | | RESPONSE TO COMMENT 9:RESPONSE REFERS TO PLAN SHEETS | | | M15.05 THROUGH M15.08.KEY NOTE ON SHEETS INDICATES | | | M15.05 THROUGH M15.08 3/4 PVC CONDENSATE TO TERMINATE | | | BEUOND EXTERIOR WALL.PLEASE ANNOTATE THE FOLLOWING: | | | | | | | | | A) EXTERIOR TERMINATION SHALL BE A MINIMUM OF 12" | | | FROM BUILDING STRUCTURE PER 2001 FBC 1503.4.4. | | | | | | B) PVC IS COMBUSTIBLE AND SHALL NOT BE INSTALLED | | | IN THE PLENUM OF THE AHU CLOSET. | | | | | | RESPONSE TO COMMENT 10: OKAY | | | | | | *******************NEW COMMENT******************** | | | | | | 11. PLAN SHEET A8.20 INDICATES THE TRASH CHUTE.PER | | | 2001 FBC 705.2.4.6, AN APPROVED AUTOMATIC SPRINKLER | | | SYSTEM SHALL BE INSTALLED AT THE TOP AND AT ALTERNATE | | | FLOOR LEVELS IN REFUSE AND LAUNDRY CHUTES AND IN THE | | | TERMINATION & INCINERATOR ROOMS. | | | | | | *****REVIEW IN PROGRESS********* |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-30 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-01-30 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-01-30 |
Time |
08:37 |
Sent To |
|
|
| Notes |
| 2006-01-30 00:00:00 | DENIED:2001 FLORIDA BUILDING CODE | | | | | | 1.PLAN SHEET AP A6.01 THROUGH A701, IT | | | APPEARS THE COORIDORS HAVE OPENINGS AT | | | CERTAIN POINTS.PLEASE INDICATE TOTAL | | | SQUARE FOOTAGE AS REQUIRED FOR 'NATURAL | | | VENTILATION'.THE OUTSIDE AIR | | | CALCULATIONS INDICATED ON PLAN SHEET | | | M15.13 DO NOT SHOW TOTAL SQUARE FOOTAGE. | | | | | | 2.PLANS INDICATE RETURN AIR JUMPERS | | | FROM THE BEDROOM AREAS.PLEASE NOTE, | | | THE RETURN AIR JUMPERS ARE TO BE SIZED | | | IN ACCORDANCE WITH 2001 FMC 601.4 | | | EXCEPTION 1 & 3.PLEASE REVISE RETURN | | | TO INCREASE TO THE REQUIRED MINIMUM. | | | | | | 3.PLANS INDICATE LOUVERED DOOR.THE | | | DOOR SCHEDULE INDICATES THIS AS BEING A | | | WOOD DOOR.THE AHU CLOSET IS CONSIDERED | | | A RETURN AIR PLENUM.THE DOOR MUST ALSO | | | MEET THE REQUIREMENT OF NON-COMBUSTIBLE | | | OR SHALL HAVE A FLAME SPREAD INDEX OF | | | NOT MORE THAN 25 AND A SMIKE DEVELOPED | | | INDEX OF NOT MORE THAN 50 WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 84.PLEASE | | | PROVIDE DOCUMENTATION ON THE DOORS. | | | | | | 4.PLEASE NOTE, PER 2001 FMC 603.1.3 4" | | | CLEARANCE AROUND THE AIR HANDLER IS | | | REQUIRED. | | | | | | 5.PLAN SHEET M15.12 DETAILS FOR THE | | | AHUDOES NOT INDICATE AN AUXILIARY | | | DRAIN PAN WITH OVERFLOW PROTECTION AS | | | REQUIRED BY 2001 FMC 307.2.3.PLEASE | | | REVISE. | | | | | | 6.CONDENSING UNIT STANDS SHALL COMPLY | | | WITH 2001 FBC 1511.7 FOR HEIGHT | | | REQUIREMENT ABOVE FINISHED ROOF. | | | | | | 7.CONDENSING UNIT STANDS SHALL COMPLY | | | WITH 2001 FMC 301.13 & CHAPTER 15 OF THE | | | FBC FOR WIND PRESSURES. | | | | | | 8.PLEASE PROVIDE LINE SIZES FOR THE | | | REFRIGERANT LINES AS WELL AS THE | | | CONDENSATE. | | | | | | 9.PLEASE INDICATE TERMINATION OF THE | | | CONDENSATE. | | | | | | 10. PLEASE PROVIDE ENERGY AND MANUAL J | | | CALCULATIONS IN ACCORDANCE WITH 2001 FBC | | | CHAPTER 13. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (5610805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-14 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-11-10 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2007-11-15 07:28:38 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW. THE COMMENT NUMBER | | | SHALL STAY THE SAME AS THE FIRST REVIEW: | | | | | | ******FROM PREVIOUS REVIEWS: | | | (NOTE STATING "SUBSTANITAL MODIFICATIONS INCLUDING BUT | | | NOT LIMITED TO BUILDING DEPARTMENT COMMENTS II" HAS | | | CAUSED THE COMPLETE REVIEW OF EACH SHEET AND ADDED MANY | | | HOURS OF REVIEW TIME AS SOME SHEETS ONLY HAD MINOR | | | CHANGES BUT THE WHOLE SHEET WAS INDICATED IN THE | | | REVISION CLOUD. NEW COMMENTS HAVE BEEN ORIGINATED | | | BECAUSE OF CHANGES AND RE-REVIEW). | | | | | | A. OK | | | B. OK | | | 1. OK | | | 2. OK | | | | | | 3. SHT AP/A5.12 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW SF DRAINED FOR EACH | | | AREA ALONG WITH 1/2 AREA OF ALL VERTICAL | | | WALLS, INCLUDING PARAPETS, AND THE AREA | | | OF ANY ROOFS THAT DRAIN ONTO THE ROOF | | | AREAS FROM ABOVE. - SHOW THE LOCATION OF | | | ALL SECONDARY ROOF DRAINS OR SCUPPERS. | | | IF SCUPPERS ARE USED, SUBMIT A DETAIL | | | SHOWING HEIGHT, WIDTH, AND DISTANCE TO | | | FLOW LINE OFF THE ROOF. SECTION 1503.4.2****RESPONSE | | | NOTED, BUT SHEET A5.25 WAS | | | NOT SUBMITTED, AND NO CALCULATIONS | | | WITH INFORMATION REQUESTED HAS BEEN | | | LOCATED. | | | ******RESPONSE NOTED, BUT THE INTENT OF THE CODE | | | SECTION THAT REQUIRES SEPARATE PRIMARY AND SECONDARY | | | ROOF DRAINS HAS NOT BEEN MET. IF THERE IS BLOCKAGE IN | | | THE DOWNSPOUT, THEN AS INTENDED THE STORM WATER CAN | | | DRAIN OVER THE TOP OF THE COLLECTOR HEAD, BUT IF THE | | | SCUPPER OPENING IS COVERED/BLOCKED, THEN NEITHER THE | | | PRIMARY, NOR THE SECONDARY DRAIN WILL WORK. SCUPPERS | | | WILL BE REQUIRED IN THE PARAPET WALLS SIZED PER SECTION | | | 1107.3 AND A DETAIL WILL BE REQUIRED SHOWING THE | | | LENGTH, HEIGHT & WIDTH AND INDICATING THE HEIGHT OFF | | | THE ROOF AS REQUIRED IN SECTION 1503.4.2. | | | | | | 4. SHTS AP/A5.61 & AP/A5.62 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED IN FHA DESIGN | | | MANUAL PAGES 7.34 & 7.35. - LAVS SHALL | | | BE A MINIMUM OF 2' OFF THE WALL IN ORDER | | | TO BE CENTERED ON THE 48" LENGTH OF THE | | | CLEAR FLOOR SPACE. PLEASE INDICATE ON | | | PLANS. FHA DESIGN MANUAL PAGES 7.47 AND | | | 7.48. - WATER CLOSET OPENING SHALL BE A | | | MINIMUM OF 33" WITH THE WATER CLOSET 18" | | | OFF ONE FIXTURE AND 15" OFF THE OTHER | | | FIXTURE TO THE CENTER OF THE W/C. FHA | | | DESIGN MANUAL PAGES 7.43, 7.44, & 7.45. ****RESPONSE | | | NOTED, BUT SPECIFICATION | | | "A" OR "B" HAS NOT BEEN INDICATED. ALSO | | | THE WATER CLOSET OPENING MEASUREMENTS | | | HAS NOT BEEN SHOWN ON THE FLOOR PLAN. ******RESPONSE | | | NOTED, BUT SPECIFICATION "A" OR "B" IS NOT INDICATED ON | | | THE PLANS. | | | | | | 5. OK | | | 6. OK | | | 7. OK | | | | | | 8. SUBMIT A DETAIL FOR THE COMMON USE | | | TOILET ROOMS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.16, 11-4.19, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | ****RESPONSE NOTED, BUT THE FOLLOWING | | | INFORMATION IS STILL REQUIRED ON PLANS | | | TO SHOW COMPLIANCE: | | | A. 11-4.19.3 CLEAR FLOOR SPACE (FORWARD | | | APPROACH REQUIRED). | | | ******RESPONSE NOTED, BUT PARALLEL APPROACH IS SHOWN. | | | FORWARD APPROACH IS REQUIRED. | | | B. 11-4.19.4 EXPOSED PIPES & SURFACES. ******RESPONSE | | | NOTED, BUT NOTE WAS NOT FOUND. | | | C. 11-4.19.5 FAUCETS | | | ******RESPONSE NOTED, BUT NOTE WAS NOT FOUND. | | | | | | 9. OK | | | 10. OK | | | 11. OK | | | 12. OK | | | 13. OK | | | | | | 14. AN RPZV BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THE BUILDING. SECTION | | | 608.13.2. | | | ****RESPONSE NOTED, BUT COMMENT NOT | | | ADDRESSED. EACH BUILDING IS REQUIRED TO | | | HAVE ITS OWN RPZV BACKFLOW. INDICATE ON | | | PLANS AT THE WATER SERVICE TO THE | | | BUILDING. | | | ******RESPONSE NOTED, BUT THE RPZV BACKFLOW WAS NOT | | | FOUND ON THE CIVIL SHEET #10. PLEASE CLARIFY. | | | | | | 15. SUBMIT A WATER LAYOUT FOR BUILDING | | | AND WATER RISER DIAGRAMS. SHOW ALL PIPE | | | SIZES, VALVES, WATER HAMMER ARRESTORS, | | | (INSTALLED IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING). SECTIONS 104.3.1.1, | | | 606.1, 606.2, 608.13.2 & PDI-WH 201. | | | ****RESPONSE NOTED, BUT THE WATER RISER | | | DIAGRAM SHALL BE SUBMITTED IN ISOMETRIC | | | FORM. WATER HAMMER ARRESTORS AND | | | REQUIRED VALVES CAN NOT BE SHOWN ON A | | | FLAT PIPING LAYOUT. | | | ******RESPONSE NOTED, BUT THE WATER DISTRIBUTION SYSTEM | | | RISERS SHALL BE SHOWN IN ISOMETRIC FORM FROM THE | | | ENTRANCE OF THE BUILDING THRU THE 5TH FLOOR. SHT | | | AP/P14.26 AS INDICATED WAS THE STORM WATER RISER | | | DIAGRAM, NOT THE POTABLE WATER RISER DIAGRAM. | | | | | | 16. SUBMIT A BUILDING SANITARY DRAIN | | | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, TRAPS, OFFSETS, RISER LOCATIONS | | | WITH RISER NUMBERS, DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM ETC. SECTION | | | 104.3.1.1. | | | ***COMMENT RESPONSE NOTED, BUT COMMENT | | | NOT ADDRESSED. | | | ******RESPONSE NOTED, BUT SHT AP/P14.23 ONLY SHOWS | | | RISERS, NOT THE BUILDING DRAIN ISOMETRIC, AND SHTS | | | AP/P14.24 & AP/P14.25 DO NOT SHOW THE RISER LOCATIONS | | | WITH THE RISER DESIGNATION NUMBERS. | | | | | | 17. SUBMIT A BUILDING STORM DRAIN | | | ISOMETRIC RISER DIAGRAM, SHOWING ALL | | | PIPE SIZES, RISER LOCATIONS WITH RISER | | | NUMBERS, AND SQUARE FEET AS IT | | | ACCUMULATES IN THE SYSTEM. SECTION | | | 104.3.1.1. | | | ****RESPONSE NOTED, BUT NOT ADDRESSED. | | | SEE COMMENT RESPONSE TO COMMENT #10. | | | RISER REQUIRED FOR ALL HORIZONTAL | | | STORM DRAINAGE. | | | ******RESPONSE NOTED, BUT SHT AP/P14.22 SHOWS NO STORM | | | BUILDING DRAIN ISOMETRIC.--SHT AP/P14.26 SHOW ALL | | | CLEANOUTS REQUIRED BY SECTION 1101.8.--P-TRAPS ARE | | | NOT REQUIRED ON THE STORM SYSTEM.--5S, A MINIMUM 5" | | | PIPE IS REQUIRED FOR THE 4" GD-1 1720SF OR INDICATE | | | MINIMUM 1/4"/FT SLOPE. TABLE 1106.3.--1S, PIPE SIZE | | | IS DECREASED IN SIZE IN THE DIRECTION OF FLOW | | | DOWNSTREAM OF1858SF. UPSTREAM SHOWS 8" BUT DOWNSTREAM | | | IS SHOWN AS 6". SECTION 704.2. 8" PIPE REQUIRED. | | | | | | 18. OK | | | | | | **************NEW COMMENTS************** | | | | | | 1B. OK | | | 2B. OK | | | 3B. OK | | | | | | 4B. SUBMIT A DETAIL FOR THE DOWNSPOUTS | | | AND THE COLLECTOR HEAD AT THE TOP. | | | INDICATE SIZE OF DOWNSPOUT, LENGTH, | | | WIDTH & HEIGHT OF COLLECTOR HEAD. | | | INDICATE ON ROOF PLAN SQUARE FOOTAGE | | | DRAINING INTO EACH DOWNSPOUT. | | | ******RESPONSE NOTED, BUT LENGHT, WIDTH & HEIGHT ARE | | | NOT SHOWN FOR THE COLLECTOR HEAD. A CUT VIEW ONLY WAS | | | SUBMITTED, PLEASE PROVIDE AN ELEVATION DETAIL TO SHOW | | | ALL MEASUREMENTS. | | | | | | 5B. SECONDARY DRAINAGE AND SEPARATE | | | SYSTEMS ARE REQUIRED FOR THE ROOF | | | DRAINAGE PER SECTIONS 1107.1 & 1107.2. | | | PLEASE INDICATE THE LOCATION AND SIZE OF | | | THE SECONDARY ROOF DRAINAGE. SUBMIT A | | | DETAIL FOR THE SECONDARY ROOF DRAINS. ******RESPONSE | | | NOTED, BUT THE INTENT OF THE CODE SECTION THAT REQUIRES | | | SEPARATE PRIMARY AND SECONDARY ROOF DRAINS HAS NOT BEEN | | | MET. IF THE DOWNSPOUT BACKS UP THEN AS INTENDED THE | | | STORM WATER CAN DRAIN OVER THE TOP OF THE COLLECTOR | | | HEAD, BUT IF THE SCUPPER OPENING IS COVERED/BLOCKED, | | | THEN NEITHER THE PRIMARY, NOR THE SECONDARY DRAIN WILL | | | WORK. SCUPPERS WILL BE REQUIRED IN THE PARAPET WALLS | | | SIZED PER SECTION 1107.3 AND A DETAIL WILL BE REQUIRED | | | SHOWING THE HEIGHT & WIDTH AND INDICATING THE HEIGHT | | | OFF THE ROOF AS REQUIRED IN SECTION 1503.4.2. | | | | | | 6B. SHTS AP A5.05, AP A5.13, AND AP A5.24 | | | ROOF PLAN SHOWS UNITS AND FIXTURES. | | | PLEASE CLARIFY. SECTION 104.2.1. | | | | | | ********NEW COMMENTS 3RD REVIEW******** | | | | | | 1C. SHT AP/P14.01 UNIT A3 NOTE STATES "1/2IN CW/HW | | | DOWN, BUT ONLY SHOWS C/W. PLEASE CLARIFY. SECTION | | | 105.2.1. | | | | | | 2C. SHT AP/P14.03 UNITS C2 & C3 WERE DELETED FROM THE | | | SHEET, BUT NO REVISION IS INDICATED. PLEASE CLOUD AND | | | INDICATE REVISION WITH A NUMBERED DELTA TRIANGLE. | | | SECTION 104.2.1.3. | | | | | | 3C. SHT AP/P14.04 BOTH UNITS, IDENTIFY ALL STACK RISERS | | | AND INDICATE WHICH MAIN STACK THEY CONNECT TO.--2ND | | | FLOOR CLUBHOUSE PLUMBING PLAN. THE KITCHEN SINK SHALL | | | DISCHARGE DOWNSTREAM OF THE HORIZONTAL WET VENT FOR THE | | | TOILET ROOM FIXTURES. SECTION 909.1.--INDICATE ON | | | WHAT PAGE THE SANITARY LINE CONTINUES. | | | | | | 4C. SHT AP/P14.05 IDENTIFY ALL STACKS. INDICATE WHICH | | | SHEET THE PIPE CONTINUES AT THE COMMON AREAS.--4" | | | GD-1, BY THE TRASH ROOM SQUARE FOOTAGE IS NOT LEGIBLE. | | | SECTION 104.2.1.--THE BUILDING STORM DRAIN LINE HAS | | | BEEN DELETED ON ONE SIDE OF THE SHEET. WAS IT RELOCATED | | | TO ANOTHER SHEET? PLEASE CLARIFY. SECTION 104.2.1.-- | | | INDICATE THE RISER NUMBERS SO THEY CAN BE LOCATED ON | | | THE NEXT LEVEL. (MANY RISERS HAVE THE SAME NUMBER. EACH | | | RISER SHALL HAVE ITS OWN NUMBER SO IT CAN BE TRACED | | | FROM THE GROUND FLOOR THRU THE ROOF. (SEE RISERS S-10, | | | S-11 & S-12 FOR EXAMPLE). (IF THERE ARE TYPICAL RISERS, | | | THEN INDICATE THAT IT IS A TYPICAL RISER, SUCH AS RISER | | | S-11 AND THEN SHOW WHICH RISER NUMBERS ARE TYPICAL). | | | | | | 5C. SHT AP/P14.06 INDICATE THE RISER NUMBERS SO THEY | | | CAN BE LOCATED ON THE NEXT LEVEL. (MANY RISERS HAVE THE | | | SAME NUMBER. EACH RISER SHALL HAVE ITS OWN NUMBER SO IT | | | CAN BE TRACED FROM THE GROUND FLOOR THRU THE ROOF. (SEE | | | RISER S-33 FOR EXAMPLE). (IF THERE ARE TYPICAL RISERS, | | | THEN INDICATE THAT IT IS A TYPICAL RISER, SUCH AS RISER | | | S-11 AND THEN SHOW WHICH RISER NUMBERS ARE TYPICAL). | | | | | | 6C. SHT AP/P14.07 IDENTIFY ALL RISERS. SECTION 104.2.1. | | | --MINIMUM 5" REQUIRED DOWNSTREAM OF 4" GD-1 1200SF & | | | DOWNSTREAM OF 4" GD-1 836SF. (MANY RISERS HAVE THE SAME | | | RISER NUMBER). TABLE 1106.3. | | | | | | 7C. SHT AP/P14.08 IDENTIFY ALL RISERS. SECTION 104.2.1. | | | (MANY RISERS HAVE THE SAME RISER NUMBER). | | | | | | 8C. SHT AP/P14.09 SHOW THE PIPE SIZES TO W/1 RISERS. | | | TABLES 604.3 & 604.5. | | | | | | 9C. SHT AP/P14.10 SHOW THE PIPE SIZES TO W/1 RISERS. | | | TABLES 604.3 & 604.5. | | | | | | 10C. SHT AP/P14.11 SHOW THE PIPE SIZES TO W/1 RISERS. | | | TABLES 604.3 & 604.5.--INDICATE WHERE THE NEW 4" CW | | | FEEDS FROM AND CONTINUES ON TO. SECTION 104.2.1. | | | | | | 11C. SHT AP/P14.12 FULL OPEN VALVES ARE REQUIRED PER | | | SECTION 606.1(3). PLEASE INDICATE ON PLANS. | | | | | | 12C. SHT AP/P14.13 PLAN KEY NOTES 3 & 4 WERE NOT | | | LOCATED. PLEASE CLARIFY & CORRELATE. SECTION 104.2.1. | | | --SHOW ALL RISER DESIGNATION NUMBERS . | | | | | | 13C. SHT AP/P14.14 PLAN KEY NOTES 3 & 4 WERE NOT | | | LOCATED. PLEASE CLARIFY & CORRELATE. SECTION 104.2.1. | | | --ONE RISER DESIGNATION S/2 NOT INDICATING WHERE THE | | | RISER IS LOCATED.--ONE RISER (2), THE 4" SANT. | | | STACK FITTING APPEARS TO BE GUIDING THE THE WASTE | | | AGAINST THE FLOW. SECTION 706.3.--SHOW ALL RISER | | | DESIGNATION NUMBERS . | | | | | | 14C. SHT AP/P14.15 NO REVISION NUMBER IS INDICATED IN | | | THE DELTA TRIANGLE.--NO PLAN KEY NOTES NUMBERS ARE | | | INDICATED AT THE UNITS NEXT TO THE MATCHLINE. SECTION | | | 104.2.1.--SHOW ALL RISER DESIGNATION NUMBERS . | | | | | | 15C. SHT AP/P14.16 NO REVISION NUMBER OR DELTA | | | INDICATED.--PLAN KEY NOTES 3 & 4 NOT LOCATED.-- | | | SHOW ALL RISER DESIGNATION NUMBERS .SECTION 104.2.1. | | | | | | 16C. SHT AP/P14.17 NO PLAN KEY NOTES INDICATED FOR | | | NUMBERS 1 & 2. PLEASE CLARIFY & CORRELATE. SECTION | | | 104.2.1. | | | | | | 17C. SHT AP/P14.19 NO PLAN KEY NOTES INDICATED FOR | | | NUMBERS 1 & 2. PLEASE CLARIFY & CORRELATE. SECTION | | | 104.2.1. | | | | | | 18C. SHT AP/P14.21SANITARY RISERS 1, 4, 5, 6 & 7 EVERY | | | VENT STACK SHALL CONNECT TO THE BASE OF THE DRAINAGE | | | STACK AT OR BELOW THE LOWEST HORIZONTAL BRANCH. SECTION | | | 903.4. PLEASE CORRECT ON RISERS.--SANT RISER 7 | | | TOTAL DFU'S IS 24, NOT 20. (BATHROOM GROUP IS 5, PLUS | | | ONE FOR THE EXTRA LAV) TABLE 709.1 (SEE DEFINITION OF | | | BATHROOM GROUP).--DETAIL #4, A FULL OPEN VALVE IS | | | REQUIRED ON THE SUPPLY LINE TO THE WATER HEATER. | | | SECTION 606.1(7). | | | | | | 19C. SHT AP/P14.22 ALL UNITS. A WATER HAMMER ARRESTOR | | | IS REQUIRED AT THE DISHWASHER LINE PER SECTION 604.9. | | | --UNITS B1, B2, B3 & B4 DO NOT REFLECT THE FLOOR | | | PLAN. SECTION 104.2.1.--UNITS C2 & C3. NO FLOOR | | | PLANS ARE SUBMITTED FOR THESE UNITS. PLEASE CLARIFY. | | | SECTION 104.2.1. | | | | | | 20C. SHT AP/P14.23 SANITARY RISERS 1 THRU 9 & 19 ARE | | | NOT SUBMITTED. PLEASE CLARIFY. SECTION 104.2.1. | | | | | | 21C. SHTS AP/P14.24 & AP/P14.25 INDICATE THE RISER | | | DESIGNATION NUMBERS AT THE BASE OF EACH RISER TO BE | | | ABLE TO TRACK THE RISERS FROM FLOOR TO FLOOR. SECTION | | | 104.2.1. | | | | | | 22C. SHT AP/P14.26 SHOW THE CLEANOUTS REQUIRED IN | | | SECTION 1101.8.--P-TRAPS ARE NOT REQUIRED IN THE | | | STORM SYSTEM.--MINIMUM 5" REQUIRED AT 4" GD-1 | | | 17720SF OR SHOW SLOPE MINIMUM 1/4"/FT.--8" REQUIRED | | | AT 7176SF. 6" WAS SHOWN. PIPE WAS REDUCED IN THE | | | DIRECTION OF FLOW AND IS NOT ALLOWED PER SECTION 704.2. | | | 8" PIPE IS REQUIRED. TABLE 1106.3. | | | | | | 23C. SHT AP/P14.27 SHOW THE CLEANOUTS REQUIRED IN | | | SECTION 1101.8.--P-TRAPS ARE NOT REQUIRED IN THE | | | STORM SYSTEM. | | | | | | 24C. NOTE: REVISION #1 HAS BEEN DELETED FROM THE TITLE | | | BLOCK REVISION INDEX FROM MOST ALL PLUMBING SHEETS. ALL | | | REVISIONS SHALL BE INDICATED IN THE REVISION INDEX FOR | | | RECORD KEEPING. PLEASE SHOW ALL REVISIONS THROUGHOUT | | | THE LENGTH OF THE PROJECT. SECTION 104.2.1.3. | | | | | | 25C. THERE IS NO KEY PLAN OR COLUMN LINES TO INDICATE | | | WHAT SECTION OF THE BUILDING IS LOCATED ON WHICH SHEET. | | | MATCH LINES DO NOT INDICATE INFORMATION TO DIRECT | | | INFORMATION FROM ONE SHEET TO ANOTHER. IT IS TIME | | | CONSUMING WHEN ONE SECTION OF THE PLANS HAS NO RELATION | | | TO ANOTHER WITH INFORMATION SUBMITTED. PLEASE SUBMIT A | | | KEY PLAN ON EACH SHEET OF THE FLOOR PLANS AS HAS BEEN | | | SUBMITTED ON THE ARCHITECTURAL SHEET IN ORDER TO | | | EXPEDITE THE PLAN REVIEWS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6713 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-10-11 |
Time |
13:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-10-11 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2006-10-11 15:00:48 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | FROM PREVIOUS REVIEW. THE COMMENT NUMBER | | | SHALL STAY THE SAME AS THE FIRST REVIEW: | | | | | | A. OK | | | B. OK | | | 1. OK | | | 2. OK | | | | | | 3. SHT AP/A5.12 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW SF DRAINED FOR EACH | | | AREA ALONG WITH 1/2 AREA OF ALL VERTICAL | | | WALLS, INCLUDING PARAPETS, AND THE AREA | | | OF ANY ROOFS THAT DRAIN ONTO THE ROOF | | | AREAS FROM ABOVE. - SHOW THE LOCATION OF | | | ALL SECONDARY ROOF DRAINS OR SCUPPERS. | | | IF SCUPPERS ARE USED, SUBMIT A DETAIL | | | SHOWING HEIGHT, WIDTH, AND DISTANCE TO | | | FLOW LINE OFF THE ROOF. SECTION 1503.4.2****RESPONSE | | | NOTED, BUT SHEET A5.25 WAS | | | NOT SUBMITTED, AND NO CALCULATIONS | | | WITH INFORMATION REQUESTED HAS BEEN | | | LOCATED. | | | | | | 4. SHTS AP/A5.61 & AP/A5.62 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED IN FHA DESIGN | | | MANUAL PAGES 7.34 & 7.35. - LAVS SHALL | | | BE A MINIMUM OF 2' OFF THE WALL IN ORDER | | | TO BE CENTERED ON THE 48" LENGTH OF THE | | | CLEAR FLOOR SPACE. PLEASE INDICATE ON | | | PLANS. FHA DESIGN MANUAL PAGES 7.47 AND | | | 7.48. - WATER CLOSET OPENING SHALL BE A | | | MINIMUM OF 33" WITH THE WATER CLOSET 18" | | | OFF ONE FIXTURE AND 15" OFF THE OTHER | | | FIXTURE TO THE CENTER OF THE W/C. FHA | | | DESIGN MANUAL PAGES 7.43, 7.44, & 7.45. ****RESPONSE | | | NOTED, BUT SPECIFICATION | | | "A" OR "B" HAS NOT BEEN INDICATED. ALSO | | | THE WATER CLOSET OPENING MEASUREMENTS | | | HAS NOT BEEN SHOWN ON THE FLOOR PLAN. | | | | | | 5. SHT AP/A5.56 INDICATE MATERIAL FOR | | | GRAB BAR BLOCKING. SECTION 104.2.1. | | | ***RESPONSE NOTED, (SEE AP A5.56), BUT | | | SHT AP/A5.56 HAS NOT BEEN SUBMITTED. | | | PLEASE CLARIFY. | | | | | | 6. OK | | | 7. OK | | | | | | 8. SUBMIT A DETAIL FOR THE COMMON USE | | | TOILET ROOMS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.16, 11-4.19, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | ****RESPONSE NOTED, BUT THE FOLLOWING | | | INFORMATION IS STILL REQUIRED ON PLANS | | | TO SHOW COMPLIANCE: | | | A. 11-4.19.3 CLEAR FLOOR SPACE (FORWARD | | | APPROACH REQUIRED). | | | B. 11-4.19.4 EXPOSED PIPES & SURFACES. | | | C. 11-4.19.5 FAUCETS | | | | | | 9. SHTS AP/P14.02 UNITS B3 & B4 MAXIMUM | | | 4 FU ON A 2" WET VENT IN MASTER BATH. | | | TABLE 909.3. | | | ****RESPONSE NOTED, BUT THE RISER | | | DIAGRAM DOES NOT REFLECT THE FLOOR PLAN | | | AS THE FLOOR PLAN SHOWS 3" AND THE RISER | | | DIAGRAM SHOWS 2-1/2" FOR THE WET VENT. | | | CORRELATE RISER AND FLOOR PLAN. SECTION | | | 104.2.1. (INFORMATION NOT INDICATED ON SHT | | | P14.06 AS INDICATED IN RESPONSE). | | | | | | 10. OK | | | | | | 11. SHT AP/P14.26 OFFSETS IN THE SANT. | | | SHALL BE SHOWN ON EITHER BLDG. DRAIN | | | ISOMETRIC RISER DIAGRAM, OR SANT. RISER | | | DIAGRAMS. SECTION 104.2.1. | | | ****RESPONSE NOTED, BUT WHEN THE SANT. | | | RISER FROM UNDERGROUND IS ABOVE THE | | | CEILING OF THE FIRST FLOOR, THE RISER | | | SPLITS AND OFFSETS INTO OTHER RISERS. | | | (EXAMPLE RISER 2,3,6 COMES OUT OF THE | | | GROUND AND OFFSETS ABOVE THE CEILING AND | | | SPLITS INTO THREE SEPARATE RISERS. | | | BUILDING DRAIN ISOMETRIC RISER SHALL | | | REFLECT THIS PIPING. SECTION 104.3.1.1. | | | | | | 12. OK | | | 13. OK | | | | | | 14. AN RPZV BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THE BUILDING. SECTION | | | 608.13.2. | | | ****RESPONSE NOTED, BUT COMMENT NOT | | | ADDRESSED. EACH BUILDING IS REQUIRED TO | | | HAVE ITS OWN RPZV BACKFLOW. INDICATE ON | | | PLANS AT THE WATER SERVICE TO THE | | | BUILDING. | | | | | | 15. SUBMIT A WATER LAYOUT FOR BUILDING | | | AND WATER RISER DIAGRAMS. SHOW ALL PIPE | | | SIZES, VALVES, WATER HAMMER ARRESTORS, | | | (INSTALLED IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING). SECTIONS 104.3.1.1, | | | 606.1, 606.2, 608.13.2 & PDI-WH 201. | | | ****RESPONSE NOTED, BUT THE WATER RISER | | | DIAGRAM SHALL BE SUBMITTED IN ISOMETRIC | | | FORM. WATER HAMMER ARRESTORS AND | | | REQUIRED VALVES CAN NOT BE SHOWN ON A | | | FLAT PIPING LAYOUT. | | | | | | 16. SUBMIT A BUILDING SANITARY DRAIN | | | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, TRAPS, OFFSETS, RISER LOCATIONS | | | WITH RISER NUMBERS, DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM ETC. SECTION | | | 104.3.1.1. | | | ***COMMENT RESPONSE NOTED, BUT COMMENT | | | NOT ADDRESSED. | | | | | | 17. SUBMIT A BUILDING STORM DRAIN | | | ISOMETRIC RISER DIAGRAM, SHOWING ALL | | | PIPE SIZES, RISER LOCATIONS WITH RISER | | | NUMBERS, AND SQUARE FEET AS IT | | | ACCUMULATES IN THE SYSTEM. SECTION | | | 104.3.1.1. | | | ****RESPONSE NOTED, BUT NOT ADDRESSED. | | | SEE COMMENT RESPONSE TO COMMENT #10. | | | RISER REQUIRED FOR ALL HORIZONTAL | | | STORM DRAINAGE. | | | | | | 18. OK | | | | | | **************NEW COMMENTS************** | | | | | | 1B. ALL ARCHITECTURAL SHEETS. THE TITLE | | | BLOCK SHALL CONTAIN THE PRINTED NAME OF | | | THE PERSON SEALING THE DOCUMENT. FAC 61G1-16.004(6) & | | | FS F81.2055. | | | | | | 2B. SHTS AP/P14.09 THRU AP/1412 PIPING FOR | | | THE FIXTURES ON THE SECOND THRU 4TH FLOORS | | | SHALL BE SHOWN ON THE FLOOR PLAN WITH | | | THE FIXTURES, (SHTSP14.13 THRU P14.16). | | | SECTION 104.2.1.3. | | | | | | 3B. SHTS AP A5.60, AP A5.61, AP A5.62 | | | REFER TO SHEET A5.58. THIS SHEET HAS NOT | | | BEEN SUBMITTED. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | | | | 4B. SUBMIT A DETAIL FOR THE DOWNSPOUTS | | | AND THE COLLECTOR HEAD AT THE TOP. | | | INDICATE SIZE OF DOWNSPOUT, LENGTH, | | | WIDTH & HEIGHT OF COLLECTOR HEAD. | | | INDICATE ON ROOF PLAN SQUARE FOOTAGE | | | DRAINING INTO EACH DOWNSPOUT. | | | | | | 5B. SECONDARY DRAINAGE AND SEPARATE | | | SYSTEMS ARE REQUIRED FOR THE ROOF | | | DRAINAGE PER SECTIONS 1107.1 & 1107.2. | | | PLEASE INDICATE THE LOCATION AND SIZE OF | | | THE SECONDARY ROOF DRAINAGE. SUBMIT A | | | DETAIL FOR THE SECONDARY ROOF DRAINS. | | | | | | 6B. SHTS AP A5.05, AP A5.13, AND AP A5.24 | | | ROOF PLAN SHOWS UNITS AND FIXTURES. | | | PLEASE CLARIFY. SECTION 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6713 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2006-01-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-01-18 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-01-17 |
Time |
19:00 |
Sent To |
|
|
| Notes |
| 2006-01-18 00:00:00 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | FBC-2001 BUILDING | | | FBC-2001 CHAPTER 1 | | | FBC-2001 CHAPTER 11 | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | A. PLANS WERE SUBMITTED AS LOOSE SHEETS | | | AND AS SUCH IS NOT ACCEPTABLE. PLEASE | | | SUBMIT PLANS IN BOUND SETS. SECTION | | | 104.2.1.3. | | | B. PERMITS INDICATE 3 SEPARATE | | | BUILDINGS, BUT PLANS INDICATE ONE | | | BUILDING. PLEASE CLARIFY. SECTION | | | 104.2.1. | | | 1. ALL ARCHITECTURAL SHEETS, (EXCEPT FOR | | | STRUCTURAL), ARE NOT SEALED AS REQUIRED | | | IN SECTION 104.2.2 & FAC 61G1-16.003 | | | 61G1-16.004(5) & FS 481.2055. | | | 2. SHTS AP/A1.02 & AP/A1.03 SHOWN IN | | | DRAWING INDEX ON SHT AP/A1.01 HAVE NOT | | | BEEN SUBMITTED. SECTION 104.2.1. | | | 3. SHT AP/A5.04 SUBMIT CALCULATIONS FOR | | | PRIMARY AND SECONDARY ROOF DRAINS PER | | | SECTIONS 1106 & 1107 AND ALL | | | SUBSECTIONS. SHOW SF DRAINED FOR EACH | | | AREA ALONG WITH 1/2 AREA OF ALL VERTICAL | | | WALLS, INCLUDING PARAPETS, AND THE AREA | | | OF ANY ROOFS THAT DRAIN ONTO THE ROOF | | | AREAS FROM ABOVE. - SHOW THE LOCATION OF | | | ALL SECONDARY ROOF DRAINS OR SCUPPERS. | | | IF SCUPPERS ARE USED, SUBMIT A DETAIL | | | SHOWING HEIGHT, WIDTH, AND DISTANCE TO | | | FLOW LINE OFF THE ROOF. SECTION 1503.4.2 | | | 4. SHTS AP/A5.61 & AP/A5.62 INDICATE | | | SPECIFICATION "A" OR "B" FOR EACH UNIT | | | OR BATHROOM AS REQUIRED IN FHA DESIGN | | | MANUAL PAGES 7.34 & 7.35. - LAVS SHALL | | | BE A MINIMUM OF 2' OFF THE WALL IN ORDER | | | TO BE CENTERED ON THE 48" LENGTH OF THE | | | CLEAR FLOOR SPACE. PLEASE INDICATE ON | | | PLANS. FHA DESIGN MANUAL PAGES 7.47 AND | | | 7.48. - WATER CLOSET OPENING SHALL BE A | | | MINIMUM OF 33" WITH THE WATER CLOSET 18" | | | OFF ONE FIXTURE AND 15" OFF THE OTHER | | | FIXTURE TO THE CENTER OF THE W/C. FHA | | | DESIGN MANUAL PAGES 7.43, 7.44, & 7.45. | | | 5. SHT AP/A5.56 INDICATE MATERIAL FOR | | | GRAB BAR BLOCKING. SECTION 104.2.1. | | | 6. SHTS AP/A5.50 THRU AP/A5.55 LAV SHALL | | | BE 34" TO TOP OF FIXTURE RIM, NOT 36" AS | | | SHOWN. FHA DESIGN MANUAL PAGE 7.52. | | | 7. SHTS AP/A6.01 THRU AP/A6.04 INDICATE | | | THE BLDG. NUMBERS FOR EACH OF THE | | | BUILDING ELEVATIONS. | | | 8. SUBMIT A DETAIL FOR THE COMMON USE | | | TOILET ROOMS SHOWING COMPLIANCE WITH | | | SECTIONS 11-4.16, 11-4.19, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | 9. SHTS AP/P14.02 UNITS B3 & B4 MAXIMUM | | | 4 FU ON A 2" WET VENT IN MASTER BATH. | | | TABLE 909.3 | | | 10. SHT AP/P14.05 VENTS ARE REQUIRED FOR | | | THE FLOOR DRAINS. SECTION 901.2.1. - | | | CLEANOUTS ARE REQUIRED IN THE SANT. | | | BUILDING DRAIN AT ALL CHANGES OF | | | DIRECTION OVER 45 DEGREES. SECTION | | | 708.3.3. | | | 11. SHT AP/P14.26 OFFSETS IN THE SANT. | | | SHALL BE SHOWN ON EITHER BLDG. DRAIN | | | ISOMETRIC RISER DIAGRAM, OR SANT. RISER | | | DIAGRAMS. SECTION 104.2.1. | | | 12. SHT AP/P14.27 SANT. RISER S/9, | | | PLEASE INDICATE FIXTURE TYPE FOR FIXTURE | | | L-3. THIS IS NOT SHOWN ON PLUMBING | | | FIXTURE SCHEDULE. SECTION 104.2.1. | | | 13. SHT AP/P14.27 WATER HEATER PIPING | | | DETAIL, THERMAL EXPANSION CONTROL IS | | | REQUIRED PER SECTION 607.3.2. PLEASE | | | INDICATE METHOD. - DIELECTRIC UNIONS ARE | | | NOT APPROVED FOR WATER SUPPLY. | | | DIELECTRIC COUPLING TO BE USED. | | | 14. AN RPZV BACKFLOW IS REQUIRED ON THE | | | WATER SERVICE TO THE BUILDING. SECTION | | | 608.13.2. | | | 15. SUBMIT A WATER LAYOUT FOR BUILDING | | | AND WATER RISER DIAGRAMS. SHOW ALL PIPE | | | SIZES, VALVES, WATER HAMMER ARRESTORS, | | | (INSTALLED IN AN "EFFECTIVE RANGE" NOT | | | IN THE CEILING). SECTIONS 104.3.1.1, | | | 606.1, 606.2, 608.13.2 & PDI-WH 201. | | | 16. SUBMIT A BUILDING SANITARY DRAIN | | | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE | | | SIZES, TRAPS, OFFSETS, RISER LOCATIONS | | | WITH RISER NUMBERS, DFU'S AS THEY | | | ACCUMULATE IN THE SYSTEM ETC. SECTION | | | 104.3.1.1. | | | 17. SUBMIT A BUILDING STORM DRAIN | | | ISOMETRIC RISER DIAGRAM, SHOWING ALL | | | PIPE SIZES, RISER LOCATIONS WITH RISER | | | NUMBERS, AND SQUARE FEET AS IT | | | ACCUMULATES IN THE SYSTEM. SECTION | | | 104.3.1.1. | | | 18. SUBMIT STORM RISER DIAGRAMS SHOWING | | | ALL PIPE SIZES, OFFSETS, AND SQUARE | | | FOOTAGE DRAINED FOR EACH RISER. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] | | | | | | |
|
|
| Review Stop |
X |
PERMIT EXTENSION |
| Rev No |
1 |
Status |
N |
Date |
2008-11-05 |
|
|
Cont ID |
|
| Sent By |
dfulcher |
Date |
2008-11-05 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
dfulcher |
Date |
2008-11-05 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2008-11-05 09:22:46 | APP EXTENDED TO 2/3/09 PER RAB |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-12-22 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-12-22 |
Time |
19:39 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-12-22 |
Time |
19:18 |
Sent To |
I |
|
| Notes |
| 2006-12-22 19:34:16 | PLANNING AND ZONING**** FAILED **** | | | | | | | | | 1.PROVIDE RESPONSES TO COMMENTS IN WRITING AND | | | INDICATE THE REVISIONS ON SITE PLAN. | | | | | | 2.A MINOR AMENDMENT TO THE COURTNEY LAKES PB 1402 | | | PLANNED DEVELOPMENTIS REQUIRED TO REFLECT NUMBER OF | | | HANDICAP PARKING SPACES REQUIRED.AN APPLICATION WILL | | | NEED TO BE FILED TO THE PLANNING AND ZONING DEPARTMENT | | | AND APPROVED PRIOR TO SIGN-OFF OF BUILDING PERMIT. | | | | | | 3.PURSUANT TO SECTION 94-485(O)PAGE CD 94:273 OF THE | | | CODE, THE AMOUNT OF DISABLED PARKING SPACES PROPOSED | | | DOES NOT COMPLY.THERE ARE TWENTY (20) REQUIRED | | | PARKING SPACES THAT NEED TO BE PROVIDED.IN ADDITION, | | | THE LOCATION OF THE SPACES SHALL BE LOCATED SO THAT | | | USERS ARE NOT COMPELLED TO WALK OR OTHERWISE MOVE | | | BEHIND PARKED VEHICLES.WHY ARE THESE SPACES LOCATED | | | ACROSS DRIVE AISLES INSTEAD OF CLOSE PROXIMITY TO THE | | | BUILDING ACCESS? REVISE ACCORDINGLY. | | | | | | SHOULD YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1435 | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2006-03-03 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2006-03-03 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2006-03-03 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2006-03-03 00:00:00 | FAILED: | | | PLANNING AND ZONING DEPARTMENT | | | | | | 1. A SITE PLAN WAS NOT PROVIDED IN THE | | | SUBMITTAL PACKET. PLEASE SUBMIT A SITE | | | PLAN FOR ZONING REVIEW AND APPROVAL. | | | | | | |
|
|
|