| Plan Review Stops For Permit 05091323 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2006-03-20 |
|
|
Cont ID |
|
| Sent By |
jhiggins |
Date |
2005-11-17 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-20 |
Time |
11:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-03-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-03-20 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-20 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2006-03-20 00:00:00 | REVISION ADA |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-23 |
Time |
11:37 |
Rev Time |
3.00 |
| Received By |
shill |
Date |
2005-12-23 |
Time |
11:37 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-12-22 |
Time |
19:14 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-12-22 |
Time |
19:13 |
Sent To |
|
|
| Notes |
| 2005-12-22 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)SEE PREVIOUS LIST IN REGARDS TO A | | | BUSINESS LICENSE NUMBER FOR JMS | | | ARCHITECTURAL DESIGN, INC.A PERMIT | | | WILL NOT BE ISSUED UNTIL COMPLIANCE WITH | | | FAC61G1-16.003, .004 IS DETERMINED.AS | | | THIS CORRECTION FROM THE PREVIOUS REVIEW | | | WAS NOT ADDRESSED, A COPY OF THE TITLE | | | BLOCK HAS BEEN FORWARDED TO THE FLORIDA | | | BOARD OF ARCHITECTS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-11-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2005-11-07 |
Time |
18:29 |
Rev Time |
0.50 |
| Received By |
shill |
Date |
2005-11-07 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2005-11-07 00:00:00 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2001 | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS | | | TO THE FBC2001 | | | | | | 1.)CERTIFICATE OF AUTHORIZATION | | | REQUIRED FOR JMS ARCHITECTURAL DESIGN | | | INC.THE NUMBER IS TO BE PRINTED ON THE | | | PLAN, FAC61G1-16.003, 004.I FOUND A | | | LICENSE NUMBER FOR JMS DESIGN INC, BUT | | | NOT JMS ARCHITECTURAL DESIGN INC. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-12-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-12-07 |
Time |
06:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2005-12-07 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2005-12-07 00:00:00 | REDLINED PLANS. | | | | | | | | | ** SECTION 210.8(B)(3) IS NEW FOR THE | | | 2002 CODE AND REQUIRES ALL 15- AND | | | 20-AMPERE, 125-VOLT RECEPTACLES IN | | | NONDWELLING-TYPE KITCHENS TO BE GFCI | | | PROTECTED. THIS REQUIREMENT APPLIES TO | | | EACH AND EVERY 15- AND 20-AMPERE, | | | 125-VOLT KITCHEN RECEPTACLE, WHETHER OR | | | NOT THE RECEPTACLE SERVES COUNTERTOP | | | APPLIANCES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-10-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-10-11 |
Time |
08:19 |
Rev Time |
1.00 |
| Received By |
dpalmer |
Date |
2005-10-09 |
Time |
19:14 |
Sent To |
|
|
| Notes |
| 2005-10-11 00:00:00 | ********** UNSAT *********** | | | | | | 1)NOTE: PLEASE SEE RISER DIAGRAM WHICH | | | SHOWS #4 FOR NEW SUB PANEL "B". PLEASE | | | SEE 240.4,310.16, #4 IS ONLY RATED AT | | | 85A'S, WHICH WOULD INDICATE 90A OCP FOR | | | FEED, HOWEVER PANEL SCHEDULE "A" SHOWS | | | 100A OCP. | | | PLEASE ALSO SEE PANEL "A" SHOWS #3. | | | PLEASE CORRELATE AND ADJUST. | | | | | | 2)NOTE: PLEASE CLARIFY METHID OF | | | EQUIPMENT GROUNDING BETWEEN MAIN AND | | | PANEL"A" AND PANEL "A" AND PANEL "B> | | | 250.110,250.24, SIZED PER 250.122 | | | | | | 3)NOTE: PLEASE PROVIDE LOAD CALCULATIONS | | | FOR EXISTING SERVICE/GUTTER. IT IS KNOW | | | THAT THE SERVICE AT THIS LOCATION IS | | | EXTREMELY LOADEDAND CLOSE TO MAX | | | RATING. | | | 215.5,220 | | | | | | 4)NOTE: PLEASE SEE 700.12E WHICH | | | REQUIRES EMERGENCY/EXIT LTS TO BE WIRED | | | AHEAD OF THE LOCAL "AREA" LIGHTING. | | | SHOWN ON "B-10", HOWEVER THIS APPEARS | | | THIS SHOULD BE "B-6". | | | | | | 5)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | | RATED FOR THE AVAILABLE FAULT CURRENT. | | | PER 110.9/215.5 | | | | | | | | | ** PLEASE BE SURE TO SEE ANY POSSIBLE | | | COMMENTS FROM OTHER TRADES WHICH MAY | | | AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE REMOVE ALL OLD/VOIDED SHEETS | | | AND ONLY INSERT NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | PLEASE BE SURE TO SUBMIT ONE COPY OF ANY | | | VOIDED/REMOVED SHEETS SEPARATELY FOR | | | REFERENCE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE TO CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2005-09-28 |
|
|
Cont ID |
|
| Sent By |
nmccray |
Date |
2005-09-28 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
nmccray |
Date |
2005-09-28 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-30 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-30 |
Time |
12:05 |
Sent To |
M |
|
| Notes |
| 2006-03-30 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-03-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-14 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-14 |
Time |
10:25 |
Sent To |
P |
|
| Notes |
| 2006-03-14 00:00:00 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-01 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-01 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2005-12-20 00:00:00 | 12/20/05-TO "SHILL" DESK/RESUB | | 2005-12-01 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-11-16 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2005-11-16 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2005-09-27 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2005-09-27 00:00:00 | TO "COMM" BD#27 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2006-03-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-03-31 |
Time |
13:58 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2006-03-31 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2006-03-31 00:00:00 | SUBMITTAL FOR CONDENSER STANDS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2005-09-30 |
|
|
Cont ID |
|
| Sent By |
prafter |
Date |
2005-09-30 |
Time |
10:44 |
Rev Time |
1.00 |
| Received By |
prafter |
Date |
2005-09-30 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2005-09-30 00:00:00 | MECH. PLAN REVIEW: | | | | | | PROVISO:AHU #2 REQUIRES DUCT SMOKE | | | DETECTOR IN SUPPLY AIR FOR AUTO. FAN | | | SHUT DOWN AND CONNECTED TO FIRE ALARM | | | SYSTEM.2001 FBC/M 606.2.1 . | | | | | | PAT RAFTER 561/805/6728 OR 805/6719 | | | PATTY KRAUSS. | | | | | | PLEASE CALL IF THEAR ANY QUESTIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2006-03-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2006-03-20 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2006-03-20 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2006-03-20 00:00:00 | REVISION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2005-12-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-12-23 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-12-23 |
Time |
09:22 |
Sent To |
B |
|
| Notes |
| 2005-12-23 00:00:00 | 2 COPIES OF DBPR WORK SHTS ATTACHED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-12-20 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-12-20 |
Time |
10:36 |
Sent To |
B |
|
| Notes |
| 2005-12-20 00:00:00 | PAUL SCHMITZ | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODE PLAN | | | REVIEW | | | DENIED | | | PREVIOUS COMMENT (2) | | | DBPR WORK SHEETS NOT ATTACHED. | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-15 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2005-11-15 |
Time |
13:26 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2005-11-15 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2005-11-16 00:00:00 | PAUL SCHMITZ | | | FBC2001 FUEL GAS CODEPLAN REVIEW | | | FBC 2001 PLUMBING CODEPLAN REVIEW | | | FBC 2001 FL ACESSIBILITY CODE PLAN | | | REVIEW | | | DENIED | | | 1) SEC 1003.3 GREASE TRAPS | | | CONTACT W P BEACHWATERPLANT LAB | | | SUPERVISOR | | | INDUSTRIAL COORDINATOR, LYNN MASSON | | | OFFICE 561-822-2271E-MAIL | | | [email protected] | | | | | | 2)PLANS SHALL BE ROUTED TO DBPR | | | BUSINESS AND HOTEL DIVISION FOR | | | REVIEW. MINIMUM 2 SETS OF PLANS | | | SHALL BE REVIEWED AND STAMPED | | | AND THE TWO PAGE ?WORKSHEETS? | | | ATTACHED TO EACH SET OF PLANS | | | PRIOR TO RESUBMITTING TO CITY OF WEST | | | PALM BEACH | | | FOR REVIEW. PLEASE CONTACT DBPR | | | AT (850) 487-1395. | | | | | | 3)WHEN RE- SUBMITTING PLANS PLEASE | | | SUBMITT A | | | TRANSMITTAL LETTER FOR ALL DISCIPLINES, | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE. IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS,QUESTIONS 561-805-6692 | | | | | | | | | | | | |
|
|