| 2005-11-07 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05091291 |
| | ADD:317 3RD WY |
| | CONT: MASTERCARE SHUTTERS |
| | TEL: (561)262-1212 |
| | BLD CODE= 2001 FLORIDA BUILDING CODE * |
| | WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | PLANS DO NOT INDICATE HOW OCCUPANTS |
| | SHALL BE ABLE TO ESCAPE WHEN SHUTTERS |
| | ARE INSTALLED. |
| | 1005.4.5 SECURITY AND HURRICANE |
| | PROTECTION DEVICES. BARS, GRILLES, |
| | GRATES OR SIMILAR SECURITY DEVICES |
| | SHALL BE PERMITTED PROVIDED THE |
| | MINIMUM SIZE AND OPERATIONAL |
| | CONSTRAINTS OF SUCH DEVICES ARE IN |
| | ACCORDANCE WITH ?1005.4.2, ?1005.4.3, |
| | AND ?1005.4.4.THE TEMPORARY |
| | INSTALLATION OR CLOSURE OF STORM |
| | SHUTTERS, PANELS, AND OTHER APPROVED |
| | HURRICANE PROTECTION DEVICES SHALL BE |
| | PERMITTED ON EMERGENCY ESCAPE AND |
| | RESCUE OPENINGS IN GROUP R OCCUPANCIES |
| | DURING THE THREAT OF A STORM. |
| | SUCH DEVICES SHALL NOT BE REQUIRED TO |
| | COMPLY WITH THE OPERATIONAL |
| | CONSTRAINTS OF ?1005.4.2, ?1005.4.3 |
| | AND ?1005.4.4.WHILE SUCH PROTECTION |
| | IS PROVIDED, AT LEAST ONE MEANS OF |
| | ESCAPE FROM THE DWELLING OR DWELLING |
| | UNIT SHALL BE PROVIDED.THE MEANS OF |
| | ESCAPE SHALL BE WITHIN THE FIRST |
| | FLOOR OF THE DWELLING OR DWELLING UNIT |
| | AND SHALL NOT BE LOCATED WITHIN A |
| | GARAGE.OCCUPANTS IN ANY PART OF THE |
| | DWELLING OR DWELLING UNIT SHALL BE |
| | ABLE TO ACCESS THE MEANS OF ESCAPE |
| | WITHOUT PASSING THROUGH A LOCKABLE |
| | DOOR NOT UNDER THEIR CONTROL. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |