| Plan Review Stops For Permit 05091265 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
82 |
Status |
P |
Date |
2008-11-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-11-21 |
Time |
08:45 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2008-11-21 |
Time |
08:45 |
Sent To |
PC |
|
| Notes |
| 2008-11-21 08:46:52 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION/ REVIEWED | | | | | | SUBMITTAL NO. STEEL STAIR SHOP DRAWINGS AND | | | CALCULATIONS | | | | | | JOSE A SANCHEZ PE | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
81 |
Status |
F |
Date |
2008-11-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-11-18 |
Time |
16:45 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-11-18 |
Time |
16:45 |
Sent To |
PC |
|
| Notes |
| 2008-11-18 16:51:41 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION/ DENIED | | | | | | SUBMITTAL NO. STEEL STAIR SHOP DRAWINGS AND | | | CALCULATIONS | | | | | | 1) THRESHOLD BUILDING REQUIRING 3 SETS OF ALL DOCUMENTS | | | SUBMITTED. | | | | | | 2) STAIR ELEVATION# 1 LOWER LEFT HAND CORNER, AT THE | | | INTERMEDIATE LANDING THE HANDRAIL IS NOT CONTINUOUS | | | PAST THE LAST RISER IN THE UPPER FLIGHT OF | | | STAIRS.1009.11.4/ 1009.11.5. | | | 1009.11.4 CONTINUITY. | | | HANDRAIL-GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT | | | INTERRUPTION BY NEWEL POSTS OR OTHER OBSTRUCTIONS. | | | | | | 1009.11.5 HANDRAIL EXTENSIONS. | | | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING | | | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN | | | ADJACENT STAIR FLIGHT. WHERE HANDRAILS ARE NOT | | | CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL EXTEND | | | HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND THE TOP | | | RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREAD | | | BEYOND THE BOTTOM RISER. | | | | | | 1012.2 HEIGHT. | | | GUARDS SHALL FORM A PROTECTIVE BARRIER NOT LESS THAN 42 | | | INCHES (1067 MM) HIGH, MEASURED VERTICALLY ABOVE THE | | | LEADING EDGE OF THE TREAD, ADJACENT WALKING SURFACE OR | | | ADJACENT SEATBOARD. | | | | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
80 |
Status |
P |
Date |
2008-09-11 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2008-09-11 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2008-09-11 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2008-09-11 08:17:02 | FAIR HOUSING RAMP SPEC OK/STAMPED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
79 |
Status |
P |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-10 |
Time |
11:21 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-09-10 |
Time |
11:21 |
Sent To |
FIRE |
|
| Notes |
| 2008-09-10 11:22:54 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | REVISION NO: 28 SHEETS A0.8, A1.15 & A1.16 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
78 |
Status |
P |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-10 |
Time |
08:04 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2008-09-10 |
Time |
08:01 |
Sent To |
|
|
| Notes |
| 2008-09-10 08:06:02 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. 05-550-001 AMWERICAN STAIR SHOP DRAWINGS- | | | OK | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
77 |
Status |
F |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-09 |
Time |
16:40 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-09-09 |
Time |
16:40 |
Sent To |
PC |
|
| Notes |
| 2008-09-09 16:42:13 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO. 10-400-001 ADA RAMP ACCESS. | | | THE PROPOSED AGREEMENT IS OK, THE SUBMITTED RAMP IS NOT | | | THE ONE AGREED UPON WITH THE BUILDING OFFICAIL, FAIR | | | HOUSING GUIDELINES. | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
76 |
Status |
P |
Date |
2008-09-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-09-03 |
Time |
14:43 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-09-03 |
Time |
14:43 |
Sent To |
PC |
|
| Notes |
| 2008-09-03 14:46:20 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | REVISION NO: REVISION # 28 A0.1, A0.4A1.0, A1.5A2.0 & | | | A6.4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
75 |
Status |
P |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-12 |
Time |
09:33 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-08-12 |
Time |
09:33 |
Sent To |
PC |
|
| Notes |
| 2008-08-12 09:43:10 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. 07-200-003 | | | FIRESTOPPING JUDGEMENT C-AJ-8093 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
74 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-08 |
Time |
10:50 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-08-08 |
Time |
10:50 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 10:52:39 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. 10-340-002 | | | FAABRIC AWNING SUBMITTAL/CERTIFICATE OF FLAME | | | RESISTANCE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
73 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-08 |
Time |
10:42 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-08-08 |
Time |
10:42 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 10:46:10 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION:DENIED | | | | | | SUBMITTAL NO. 05-550-001 AS-BUILT STAIR SHOP DRAWINGS | | | | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. NOT RUBBER | | | STAMPED. | | | | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | 61G15-23.002(2)FL. ADMIN. CODE. A COVER SHEET OR | | | INDEX SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED | | | AND THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF | | | THE PRODUCTION & PREPARATION OF EACH SECTION OF THE | | | ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION | | | ON THE COVER SHEET OR INDEX. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
72 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-08 |
Time |
08:55 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-08-08 |
Time |
08:55 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 08:57:21 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. 05-500-047 | | | | | | VENT SHAFT COVER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
71 |
Status |
P |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-08 |
Time |
08:08 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2008-08-08 |
Time |
08:08 |
Sent To |
PC |
|
| Notes |
| 2008-08-08 08:09:24 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. 08-300-002 OVERHEAD GARARE DOOR |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
70 |
Status |
P |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-08-04 |
Time |
08:25 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2008-08-04 |
Time |
08:25 |
Sent To |
PC |
|
| Notes |
| 2008-08-04 08:26:38 | 20 GAUGE STORM PANELS 05-800-002 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
69 |
Status |
F |
Date |
2008-06-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-26 |
Time |
16:16 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2008-06-26 |
Time |
16:16 |
Sent To |
|
|
| Notes |
| 2008-06-26 16:42:30 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION:DENIED | | | | | | SUBMITTAL NO.FIRESTOPPING JUDGEMENT/ C-AJ-8093 | | | | | | THE SUBMITTAL FOR AN ENGINEERS JUDGEMENT IN REGARDS TO | | | THE SYSTEM NO. C-AJ-8093 HAS BEEN DENIEDIT WILL NEED TO | | | MEET THE INTENT OF 712.1.1 AND 712.1.2.WE WOULD NEED | | | ADDITIONAL INFORMATION TO BE ABLE TO DO A COMPLETE | | | REVIEW. | | | 1) THE STI DIAGRAM DOES NOT PROVIDE HOW LARGE THE HOLE | | | IS IN THE WALL NOR THE DIMENSIONS OF THE BUSWAY. NUMBER | | | 7 OF THE STANDARD INDICATES THEY CAN BE 19 INCHES X 5 | | | INCHES DEEP. | | | | | | 2) STI DIAGRAM ALSO IS NOT CLEAR AS TO HOW MANY BUSWAYS | | | ARE PENETRATING THIS RATED WALL IS THERE TWO OR FOUR | | | UNITS? THE COVER SHEET INDICATES THERE ARE THREE | | | BUSWAYS THAT ACTUALLY ARE PENETRATING THIS WALL? | | | | | | 3) STI DIAGRAM ALSO FAILS TO IDENTIFY THE CLEARENCES | | | BETWEEN THE BUSWAYS WHERE AS THE C-AJ-8093 SYSTEM | | | CLEARLY STATES THE SPACE BETWEEN THE BUSWAYS SHOULD BE, | | | PLEASE PROVIDE THESE DEMINSIONS. | | | | | | PLEASE PROVIDE THIS ADDITIONAL INFORMATION SO A | | | THOROUGH REVIEW CAN BE COMPLETED. THANK YOU. | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
68 |
Status |
P |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-03 |
Time |
10:48 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-06-03 |
Time |
10:48 |
Sent To |
B |
|
| Notes |
| 2008-06-03 10:50:28 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. 10-300-002 FABRIC AWNINGS AND FRAME S/S | | | AND LETTER FOR REMOVAL OF FABRIC IN A HIGH WIND EVENT. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
67 |
Status |
P |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-03 |
Time |
10:44 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-06-03 |
Time |
10:44 |
Sent To |
PC |
|
| Notes |
| 2008-06-03 10:48:17 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. 05-500-046 | | | DECRATIVE LOUVER FOR CUPOLA TOWER |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
66 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-03 |
Time |
10:39 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-06-03 |
Time |
10:38 |
Sent To |
PC |
|
| Notes |
| 2008-06-03 10:42:18 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO.08-300-002 | | | GARAGE MAINTENCE DOOR: PLEASE HIGHLIGHT PRESSURES THAT | | | ARE TO BE USED SEE SHEET# 4. | | | | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 106.3* PRODUCT APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
65 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-06-03 |
Time |
10:33 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-06-03 |
Time |
10:33 |
Sent To |
PC |
|
| Notes |
| 2008-06-03 10:37:14 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION:DENIED | | | | | | SUBMITTAL NO. 05-500-047 | | | VENTILATION SHAFT COVERS: PLEASE INDICATE IF THESE | | | SHAFT COVERS ARE TO THE INTERIORSIDE OF THE FAN ROOM | | | OR ARE ACTUALLY EXTERIOR LOUVERS? ADDITIONAL | | | INFORMATION REQUIRED 106.1.2. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
64 |
Status |
F |
Date |
2008-05-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-05-12 |
Time |
13:45 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2008-05-12 |
Time |
13:45 |
Sent To |
Z |
|
| Notes |
| 2008-05-12 13:52:54 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: / DENIED | | | | | | | | | REVISION NO: 27 THE NEW FIRE SAFING DETAIL C-AJ-8093 | | | INDICATES LITERATURETO 3B PLEASE PROVIDE THE REST OF | | | THE REPORT THROUGH 9D.THE PART 9 OF THIS SYSTEM IS | | | THE FIRESTOP COMPONENTS THAT MAKE UP THIS SYSTEM, IT IS | | | CURRENTLY INCOMPLETE AS DEPICTED. 712.4.1. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE.) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
63 |
Status |
P |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-28 |
Time |
15:32 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-04-28 |
Time |
15:32 |
Sent To |
PC |
|
| Notes |
| 2008-04-28 15:34:31 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO. | | | 07-200-002 | | | 09-900-007 | | | REVISION NO:26 SHET A.4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
62 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-08 |
Time |
15:32 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-04-08 |
Time |
15:32 |
Sent To |
PC |
|
| Notes |
| 2008-04-08 15:34:00 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | REVISION NO: 15, S1.16 & S7.5. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
61 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-08 |
Time |
08:05 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2008-04-08 |
Time |
08:05 |
Sent To |
PC |
|
| Notes |
| 2008-04-08 08:07:54 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | REVISION NO: STRUCTURAL REVISON # 11,12 & 15 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
60 |
Status |
F |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-09 |
Time |
09:37 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2008-04-09 |
Time |
09:37 |
Sent To |
PC |
|
| Notes |
| 2008-04-08 07:27:25 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL: NO 07-200-002 RESUBMITTAL, THERE ARE TWO | | | AREAS OF CONCERN: | | | 1) THE ORIGINAL SUBMITTAL NUMBER DOES NOT APPEAR | | | ANYWHERE ON THE PAPERWORK. | | | 2) THE ORIGINAL REVIEW ASK WHERETHIS PRODUCT WILL BE | | | APPLIED. THE RESPONCE SHEET IS NOT | | | WRITTEN ON THE DESIGN TEAMS LETTER HEAD, BUT ON THE | | | CITIES' COMMENT SHEET. PLEASE HAVE THE DESIGNERS OF | | | RECORD RESPOND | | | ON THERE OWN LETTERHEAD. | | | | | | THE RESPONCE INDICATES APPLIED TO ROOF DECK SEE SHEET | | | 1.21 THIS IS THE FLOOR PLAN OF THE 6TH LEVEL WHICH IS | | | THE POOL DECK AND HEALTH CLUB. | | | PLEASE INDICATE A SECTION WHERE THIS PRODUCT IS ALREADY | | | MENTIONED AS BEING USED FOR ROOF INSULATION FACTOR. | | | 106.1.2. ADDTIONAL INFORMATION REQUIRED. | | | | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
59 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-04-08 |
Time |
07:15 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-04-08 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2008-04-08 07:16:15 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | | | | REVISION NO: 24 & 25 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
58 |
Status |
F |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-02-27 |
Time |
13:18 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-02-27 |
Time |
13:18 |
Sent To |
PC |
|
| Notes |
| 2008-02-27 13:21:19 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO: 05.500.037 | | | FABRIC AWNINGS: | | | | | | NO INFORMATION ON THE FABRIC PORTION OF THE AWNING. | | | 3105.3.1 | | | FABRIC USED FOR AWNINGS OR FABRIC-COVERED FRAMES SHALL | | | BE FLAME RESISTANT IN ACCORDANCE WITH NFPA 701. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
57 |
Status |
F |
Date |
2008-02-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-02-27 |
Time |
12:57 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2008-02-27 |
Time |
12:57 |
Sent To |
PC |
|
| Notes |
| 2008-02-27 12:59:24 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO: 07-200.002PLEASE PROVIDE MORE | | | INFORMATION WHERE THIS PRODUCT WILL BE APPLIED? | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
56 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-29 |
Time |
09:56 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2008-01-29 |
Time |
09:56 |
Sent To |
PC |
|
| Notes |
| 2008-01-29 09:57:53 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | SUBMITTAL NO: 05-500.036 POMA ENTRANCE CANOPY |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
55 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-29 |
Time |
09:45 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2008-01-29 |
Time |
09:44 |
Sent To |
PC |
|
| Notes |
| 2008-01-29 09:56:22 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: 05.700.011 CLOCK TOWER DECRATIVE GRATE | | | DESIGN, SHOP DRAWINGS SITE SPECIFIC (POMA) |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
54 |
Status |
P |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-29 |
Time |
09:41 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2008-01-29 |
Time |
09:40 |
Sent To |
PC |
|
| Notes |
| 2008-01-29 09:44:43 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: 05-700.010EGG CRATE AWNINGS POMA) SITE | | | SPECIFIC | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
53 |
Status |
P |
Date |
2008-01-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-25 |
Time |
13:23 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-01-25 |
Time |
13:23 |
Sent To |
PC |
|
| Notes |
| 2008-01-25 13:25:34 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: 08-500-015 SHOP DRAWINGS AND CALCULATIONS | | | WINDOWS & DOORS | | | REVISION NO: |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
52 |
Status |
P |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-24 |
Time |
07:24 |
Rev Time |
0.44 |
| Received By |
jwitmer |
Date |
2008-01-24 |
Time |
07:24 |
Sent To |
PC |
|
| Notes |
| 2008-01-24 07:26:25 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: 05-500-034SCOSTA METAL TRUSSES SHOP | | | DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
51 |
Status |
F |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-15 |
Time |
10:33 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2008-01-15 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2008-01-15 10:46:18 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | | | | REVISION NO: 22, SHEETS A0.3, A0.4, LS.1 & LS.2 DENIED, | | | THESE SHEETS REFLECT THE STAIR NO. 3 AND THE LOBBY . | | | THE STAIRWAY EXTENSION UNDER THE ALTERNATE MEANS AND | | | MEETHODS DISCUSSED WITH THE DESIGN TEAM HAS NOT BEEN | | | INDICATED ON THESE PLANS. | | | SEE 403.13, EVERY REQUIRED STAIRWA SERVING FLOORS MORE | | | THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT | | | VEHICLE ACCESS SHALL COMPLY WITH SECTION 909.20 AND | | | 1019.8. | | | | | | | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
50 |
Status |
P |
Date |
2008-01-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-01-15 |
Time |
10:30 |
Rev Time |
5.55 |
| Received By |
jwitmer |
Date |
2008-01-15 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2008-01-15 10:33:12 | REVISION# 22 REVIEWED: | | | A1.1, A1.2, A1.21, A1.31, A1.32, A1.33, A1.5, A4.1, | | | A4.2,A4.5, A5.0, A5.1, A5.2 A5.6, A8.3, A8.5, A8.6 & | | | A8.8 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
49 |
Status |
P |
Date |
2007-12-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-06 |
Time |
14:56 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-12-06 |
Time |
14:56 |
Sent To |
PC |
|
| Notes |
| 2007-12-06 14:57:48 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | REVISION NO: A-19 REVISION FOR SCUPPERS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
48 |
Status |
P |
Date |
2007-11-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-20 |
Time |
14:36 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-11-20 |
Time |
14:36 |
Sent To |
PC |
|
| Notes |
| 2007-11-20 14:38:31 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | REVISION NO: 16 SHEET S4.4 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
47 |
Status |
P |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-14 |
Time |
10:17 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-11-14 |
Time |
10:17 |
Sent To |
PC |
|
| Notes |
| 2007-11-14 10:19:36 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: 10-560-003 ACCESS PANELS | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
46 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-14 |
Time |
09:42 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-11-14 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2007-11-14 09:43:43 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO: 05-500-026 | | | TRUSS SHOP DRAWINGS | | | NOTE THE PROJECT IS DESIGNED TO THE 2004 FBC , SCOSTA | | | TRUSS DESIGN DRAWINGS ALSO INDICATE THE PROJECT TO BE | | | DESIGNED TO THE 2004 FBC WHICH USES ASCE 7-02 NOT THE | | | ASCE 7-98 LISTED ON THE TRUSS ENGINEERING COVER SHEET. | | | PLEASE SEE CHAPTER 35 FOR REFERENCE STANDARDS. PLEASE | | | CORRECT THE EDITION OF ASCE 7. | | | | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAILCOMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
45 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-08 |
Time |
16:12 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2007-11-08 |
Time |
16:12 |
Sent To |
|
|
| Notes |
| 2007-11-08 16:14:12 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | REVISION NO: 16 S2-4, S7-6 & S7-7. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
44 |
Status |
P |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-08 |
Time |
07:56 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-11-08 |
Time |
07:56 |
Sent To |
|
|
| Notes |
| 2007-11-08 07:59:46 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | STRUCTURAL SHEETS: S1-8, S1-8R, S7.2, & S7.7. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
43 |
Status |
P |
Date |
2007-11-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-05 |
Time |
11:34 |
Rev Time |
2.00 |
| Received By |
jwitmer |
Date |
2007-11-05 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2007-11-05 11:36:49 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: | | | REVISION NO:13-18 : | | | A0.1,A0.3, A0.15, A1.2, A2.0, A2.1, A2.11, A3.5, A5.9 & | | | A7.2 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
42 |
Status |
P |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-30 |
Time |
11:02 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-10-30 |
Time |
11:02 |
Sent To |
PC |
|
| Notes |
| 2007-10-30 11:02:52 | SUBMITTAL FOR EGGCRATE GRILLE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
41 |
Status |
P |
Date |
2007-10-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-23 |
Time |
11:13 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-10-23 |
Time |
11:13 |
Sent To |
PC |
|
| Notes |
| 2007-10-23 11:15:17 | SUBMITTALS; | | | 10-500-002 ACCESS PANEL | | | SHORING LETTER GARAGE LEVEL 06 POOL NORTH POUR # 01 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
40 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-01 |
Time |
21:00 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2007-10-01 |
Time |
20:46 |
Sent To |
PC |
|
| Notes |
| 2007-10-01 21:03:09 | STRUCTURAL SHEETS REV # 10 DATED 11-13-06 | | | SHEETS S-1.7, S-1.7R, S-1.8, S-1.8R, S-3.1, S-7.2, | | | S-7.3 & S7.7 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
39 |
Status |
P |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-28 |
Time |
11:25 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-09-28 |
Time |
11:25 |
Sent To |
PC |
|
| Notes |
| 2007-09-28 11:30:26 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: | | | SHORING LETTERGARAGE LEVEL 06SOUTH POUR 2 | | | SUBMITTAL# 09-500-028 MAGMA LOCK | | | SHORING LETTER GARAGE LEVEL 06 POOL DECK | | | SUBMITTAL 05-500-029-R01 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
38 |
Status |
F |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-28 |
Time |
11:16 |
Rev Time |
0.56 |
| Received By |
jwitmer |
Date |
2007-09-28 |
Time |
11:16 |
Sent To |
PC |
|
| Notes |
| 2007-09-28 11:24:33 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | SUBMITTAL NO: | | | SHORING REPORT GARAGE LEVEL 06 POOL NORTH POUR# 07 | | | THE NOTARY HAS NOT FILLED OUT THE INFORMATION REQUIRED | | | FOR THE NOTARY STAMP. | | | | | | JIM WITMER C. B. O. | | | PLAN REVIEW II |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
37 |
Status |
P |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-14 |
Time |
15:32 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2007-09-14 |
Time |
15:32 |
Sent To |
PC |
|
| Notes |
| 2007-09-14 15:51:51 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION:REVIEWED | | | | | | SUBMITTAL NO: 15-300-002 | | | TREMCO FIRESTOP SEALANT DRAWING NUMBER: | | | TW-2176 | | | TR-1302 | | | TW-1158 | | | TW-2129 | | | TR-2184 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
36 |
Status |
F |
Date |
2007-09-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-14 |
Time |
14:59 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2007-09-14 |
Time |
14:59 |
Sent To |
PC |
|
| Notes |
| 2007-09-14 15:19:56 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO: 15-400-011 PRO-SLOPE | | | 1) PLEASE PROVIDE PRODUCT TESTING INFORMATION FROM A | | | NATIONAL RECONIZED TESTING AGENCY IN REGARDS TO | | | COMBUSTIBLITY OF THIS COMPOSITE MATERIAL. | | | .717.5 COMBUSTIBLES IN CONCEALED SPACES IN TYPE I OR | | | II CONSTRUCTION. COMBUSTIBLES SHALL NOT BE PERMITTED IN | | | CONCEALED SPACES OF BUILDINGS OF TYPE I OR II | | | CONSTRUCTION. | | | | | | PROVIDE INFORMATION ON THE COMBUSTIBILITY OF THIS | | | PRODUCT.703.4 NONCOMBUSTIBILITY TESTS. | | | | | | THE TESTS INDICATED IN SECTIONS 703.4.1 AND 703.4.2 | | | SHALL SERVE AS CRITERIA FOR ACCEPTANCE OF BUILDING | | | MATERIALS AS SET FORTH IN SECTIONS 602.2 , 602.3 AND | | | 602.4 IN TYPE I, II, III AND IV CONSTRUCTION. THE TERM | | | ?NONCOMBUSTIBLE? DOES NOT APPLY TO THE FLAME SPREAD | | | CHARACTERISTICS OF INTERIOR FINISH OR TRIM MATERIALS. A | | | MATERIAL SHALL NOT BE CLASSIFIED AS A NONCOMBUSTIBLE | | | BUILDING CONSTRUCTION MATERIAL IF IT IS SUBJECT TO AN | | | INCREASE IN COMBUSTIBILITY OR FLAME SPREAD BEYOND THE | | | LIMITATIONS HEREIN ESTABLISHED THROUGH THE EFFECTS OF | | | AGE, MOISTURE OR OTHER ATMOSPHERIC CONDITIONS. | | | | | | 703.4.1 ELEMENTARY MATERIALS. | | | MATERIALS REQUIRED TO BE NONCOMBUSTIBLE SHALL BE TESTED | | | IN ACCORDANCE WITH ASTM E 136. | | | | | | 703.4.2 COMPOSITE MATERIALS. | | | MATERIALS HAVING A STRUCTURAL BASE OF NONCOMBUSTIBLE | | | MATERIAL AS DETERMINED IN ACCORDANCE WITH SECTION | | | 703.4.1 WITH A SURFACING NOT MORE THAN 0.125 INCH (3.18 | | | MM) THICK THAT HAS A FLAME SPREAD INDEX NOT GREATER | | | THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 SHALL | | | BE ACCEPTABLE AS NONCOMBUSTIBLE MATERIALS. | | | | | | 2) PLEASE ALSO PROVIDE TESTING INFORMATION AS TO THE | | | DENSITY OF THIS POLYSTYRENE. | | | | | | 3) 2603.2 LABELING AND IDENTIFICATION. | | | PACKAGES AND CONTAINERS OF FOAM PLASTIC INSULATION AND | | | FOAM PLASTIC INSULATION COMPONENTS DELIVERED TO THE JOB | | | SITE SHALL BEAR THE LABEL OF AN APPROVED AGENCY SHOWING | | | THE MANUFACTURER?S NAME, THE PRODUCT LISTING, PRODUCT | | | IDENTIFICATION AND INFORMATION SUFFICIENT TO DETERMINE | | | THAT THE END USE WILL COMPLY WITH THE CODE | | | REQUIREMENTS. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
35 |
Status |
F |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-05 |
Time |
07:38 |
Rev Time |
16.00 |
| Received By |
jwitmer |
Date |
2007-09-02 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2007-09-05 07:39:14 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 480 HIBISCUS ST | | | CONT: THE TOWER GROUP | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/* WEST PALM BEACH ADMINISTRATIVE AMENDMENTS | | | | | | REVISION # 13REVIEW | | | ACTION: DENIED | | | | | | 1) SHEET A0.3 | | | 1A) PLEASE INDICATE ON THE PLAN WHERE THE NEWSROOM CAF? | | | WILL BE THIS SHEET ONLY INDICATES A NEWSROOM AND ANY | | | OTHER SHEETS THAT MAY BE INVOLVED. | | | | | | 1B) FLOOR ELEVATIONS THERE ARE VARIOUS REVISIONS IN | | | REGARDS TO FLOOR ELEVATION THAT DO NOT TAKE INTO | | | ACCOUNT VERTICAL ACCESSIBILITY, IT WILL BE DISCUSSED IN | | | DEPTH FURTHER IN THE REVIEW. | | | | | | 1C) COMMERCIAL AREA CALCULATIONS NEED TO BE | | | RECALCULATED FOR # 15. SHEET A1.5 MEZZANINE AREA HAS | | | BEEN REDESIGNED FOR UNIT # 15. | | | | | | 2) SHEET A0.15 MISSING SHEET | | | | | | 3) SHEET A1.10 | | | | | | 3A) IDENTIFY WHAT AREA IS CONSIDERED THE NEWS ROOM | | | CAF?? | | | | | | 4) SHEET A1.1 | | | | | | A) COMMERCIAL SPACE # 14 AT THE REAR OF THE SPACE THERE | | | IS A NEW 6? DROP OUT THE BACK EGRESS DOORS.1003.5.2 | | | WHERE CHANGE IN ELEVATION OF 12 INCHES (305 MM) OR LESS | | | OCCURS IN EXIT ACCESS CORRIDORS, EXITS AND EXIT | | | DISCHARGE, RAMPS COMPLYING WITH SECTION 1010 SHALL BE | | | PROVIDED. | | | 11-4.8.2 SLOPE & RISE. THE LEAST POSSIBLE SLOPE | | | SHALL BE USED FOR ANY RAMP. THE MAXIMUM SLOPE FOR A | | | RAMP IN NEW CONSTRUCTION SHALL BE 1 TO 12. THE MAXIMUM | | | RISE FOR RUN SHALL BE 30" (SEE FIGURE 16). 11-4.8.4.(2) | | | LANDINGS. ALL LANDINGS ON RAMPS SHALL NOT BE LESS THAN | | | 60" CLEAR, & THE BOTTOM OF EACH RAMP SHALL HAVE NOT | | | LESS THAN 72" OF STRAIGHT & LEVEL CLEARANCE. | | | | | | | | | 5) SHEET A1.2 | | | | | | 5A) THE ELEVATOR LOBBY HAS A NEW FINISH FLOOR HEIGHT OF | | | 18.75? NGVD IT ISN?T INDICATED AS A CHANGE WITH A DELTA | | | OR CLOUD, IS THIS A MISTAKE? REVISION# 10 STILL | | | INDICATED 18.5?. | | | | | | 5B) THE ELEVATOR LOBBY REVISION# 13 AT DOOR # 30IS | | | NOT CORRECTED IN DETAIL# 1 OF A7.2 GROUND FLOOR LEVEL. | | | | | | | | | 5C) DOOR # 23 TO AN A/C CLOSET IS ELIMINATED, M2.02 | | | INDICATES THAT AIR HANDLER UNIT # 15 IS LOCATED THERE. | | | | | | 5D) THE SWITCH GEAR ROOM, FPL TRANSFORMER VAULT AND | | | COMMERCIAL TENANT SPACE NOW ALL SHOW A 7? STEP, SHOW | | | COMPLIANCE WITH VERTICAL ACCESSIBILITY. 11-4.1.3. | | | | | | 5E) THE TRASH ROOM # 017 AND CORRIDOR ALSO HAVE | | | ACCESSIBILITY ISSUES. THIS AREA IS 6? HIGHER THAN THE | | | SURROUNDING TENANT SLABS CREATING ACCESSIBILITY | | | PROBLEMS, THE PLAN INDICATES A 3? RAMP PLUS A 6? STEP | | | AT THE FRONT OF THE BUILDING. PLEASE CORRECT THIS WHOLE | | | AREA, AGAIN VERTICAL ACCESSIBILITY. | | | | | | 5F)COMMERCIAL TENANT SPACE # 15 ALSO HAS A 6? STEP TO | | | GAIN ACCESS INTO THIS UNIT, AGAIN PLEASE INDICATE | | | COMPLIANCE WITH VERTICAL ACCESSIBILITY.11-4.1.2 | | | NOTHING IN THIS CODE SHALL BE CONSTRUED TO RELIEVE THE | | | OWNER OF ANY BUILDING, STRUCTURE OR FACILITY FROM THE | | | DUTY TO PROVIDE VERTICAL ACCESSIBILITY TO ALL LEVELS | | | ABOVE AND BELOW THE OCCUPIABLE GRADE LEVEL, REGARDLESS | | | OF WHETHER THE CODE REQUIRES AN ELEVATOR TO BE | | | INSTALLED IN SUCH BUILDING, STRUCTURE OR FACILITY, | | | | | | 6) THIS IS A COMMON COMMENT FOR ALL ELECTRICAL ROOMS ON | | | ALL FLOORS WHERE THE BLOCK WALL INDICATES A REVISION# | | | 13 TO A METAL STUD WALL AND DRYWALL NO WALL | | | IDENTIFICATION TAG IS PROVIDED INDICATING RATING. | | | | | | 7) COMMON TO ALL SHEETS INDICATING A METAL AWNING, TO | | | BE UNDER SEPARATE PERMIT WITH ASSOCIATED FEES AND | | | REVIEWS. TO GET THE PLANS ISSUED SHEET A4.0 8/24/06 THE | | | ARCHITECT SIGNED THE PLANS THAT THE BAHAMA STYLE METAL | | | SHUTTERS WOULD BE UNDER A SEPARATE PERMIT NOT PART OF | | | THE MASTER BUILDING. PLEASE PLACE NOT ON PLANS WHERE | | | THIS TYPE AWNING IS LOCATED. | | | | | | 8) SHEET A2.1 : | | | | | | 8A) THE DOOR REMOVED AGAIN INDICATES THAT IT WENT TO | | | AHU# 15 SEE SHEET M2.02 | | | | | | 8B) DOOR # 30 MOVED BEHIND THIS DOOR 4?-3? THERE IS A | | | HEAVY LINE WHAT IS THIS LINE INDICATE? | | | | | | 8C) FLOOR ELEVATION 18.75? ISN?T SHOWN AS A CHANGE SEE | | | REVISION # 10 STILL AT 18.50?. | | | | | | 9) SHEET A4.1; | | | | | | 9A)AGAIN THIS DETAIL INDICATES EXTERIOR STEPS WITHOUT | | | VERTICAL ACCESSIBILITY.NOTHING IN THIS CODE SHALL | | | BE CONSTRUED TO RELIEVE THE OWNER OF ANY BUILDING, | | | STRUCTURE OR FACILITY FROM THE DUTY TO PROVIDE VERTICAL | | | ACCESSIBILITY TO ALL LEVELS ABOVE AND BELOW THE | | | OCCUPIABLE GRADE LEVEL, REGARDLESS OF WHETHER THE CODE | | | REQUIRES AN ELEVATOR TO BE INSTALLED IN SUCH BUILDING, | | | STRUCTURE OR FACILITY, | | | SWITCH GEAR | | | TRANSFORMER VAULT | | | EXTERIOR CORRIDOR | | | COMMERCIAL TENANT# 15 | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
34 |
Status |
P |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-24 |
Time |
18:01 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-24 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2007-08-24 18:36:21 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: | | | ROOF P/T SLAB AND BEAMS AREA B POUR# 1 | | | R.C. SERIES 200 ALUMINUM CASEMENT WINDOWS L. M. I. | | | R C ALUMINUM SERIES HC200 ALUMINUM CASEMENTLMI | | | RC SERIES 2400 ST ALUMINUM SLIDING GLASS DOORS LMI |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
33 |
Status |
P |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-24 |
Time |
17:48 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-24 |
Time |
17:48 |
Sent To |
PC |
|
| Notes |
| 2007-08-24 17:50:25 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | SUBMITTAL NO: | | | 05-500-020 POMA RAILING AND CALCULATIONS -OK |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
32 |
Status |
F |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-24 |
Time |
16:25 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-24 |
Time |
16:25 |
Sent To |
PC |
|
| Notes |
| 2007-08-24 17:23:43 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | REVISION NO: SHEET S-7.7 DETAILS 12 & 13 BOTH INDICATE | | | THE USE OF 14 GAUGE TRUSS ANCHORS POURED INTO THE BEAM | | | AT THE EXTERIOR WALL LINE.A SECOND SET OF TRUSS | | | ANCHOR TWISTED STRAPS ARE DEPICTED FUTHER IN ALONG THE | | | BOTTOM CHORD OF THE TRUSS. THESE TRUSS ANCHORS ARE | | | INDICATED TO USE TWISTED STRAPS AND TO USE THREE | | | TAPCONS TO ANCHOR TO THE CONCRETE DECK. THE THREE | | | TAPCONS ARE IN A ROW NOT IN UNISON WHERE THEY WILL TAKE | | | THE LOAD EQUALLY. | | | | | | THE SECOND ISSUE IS THE METAL TRUSS LAYOUT SHEET (SHOP | | | DRAWINGS) SHOWS THE SAME DETAIL REVIEWED BY THE | | | DESIGNER OF RECORD SHOP DRAWING STAMPED WITH | | | EMBEDS AT THE WALL LINE1 PAAIR OF TSWTC5 CLIPS THAT | | | ARE WELDED TO THE EMBEDS, AND THE SECOND SET OF TRUSS | | | ANCHORS BEING TSC2.75 OR TSC4.00 WITH 3 TAPCONS SECURED | | | TO THE CONCRETE DECK TAKING THE LOAD EQUALLY. | | | | | | PLEASE COORDINATE THESE DETAILS SO ONE SYSTEM WILL BE | | | SUBMITTED TO THE BUILDING DEPARTMENT. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
31 |
Status |
P |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-24 |
Time |
16:21 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-08-24 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2007-08-24 16:25:33 | STTRUCTURAL SHEETS REVISION# 15, SHEETS: | | | S1.16 & S1.16R | | | S-1.17 & S1.17R | | | S-1.19 & S1.19R | | | S-1.34 | | | S-1.35 | | | S-3.1 | | | S-4.3 | | | S-7.3 | | | S-7.5 | | | S7.7- NOT REVIEWED / PROBLEMS WITH TRUSS ANCHORS | | | S-8.4 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
30 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-22 |
Time |
07:58 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-08-22 |
Time |
07:58 |
Sent To |
|
|
| Notes |
| 2007-08-22 08:29:24 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: | | | #08-110-002 MASONARY OPENINGS/ FRAME ELEVATIONS | | | #05-500-004 PHASE 1 / STAIR'S 1-5 | | | #07-150-001 6 MIL VISQUEEN VAPOR BARRIER | | | #07-200-001DYPLAST STYROFOAM / HI DENSITY STYROFOAM | | | 12"X18" | | | #08-050-001 ALUM EXTRUSION COATINGS | | | #08-500-004 BALCONIES SWING DOOR CONFIGURATION PACKAGE | | | #09-210-001 BROCCO STUCCO, BOND AGENT LATH TRIM & | | | WINDOW GUARD | | | #08-110-001 HOLLOW METAL DOORS/ FRAMES | | | #05-500-004 PHASE 1/ STAIRS 1-5 . | | | #04-200-002 FRI LOAD BEARING MASONARY | | | UNITSNOA06-02221.01 | | | #04-200-001 MASONRY PRODUCT DATA NOA 06-02221.01 FIRE | | | LISTINGS | | | #05-100-001 BOLLARDS, TRUSS, EMBEDS, COLUMNS, GUARDS, | | | HOIST BEAMS ONLY 2 STS SUBMITTED | | | #04-100-001 MOTTAR, WHITE PORTLAND CEMENT TITAN | | | #11-450-001 GE RESIDEENTIAL APPLIANCES#14-560-001 TRASH | | | CHUTEDETAILS | | | #05-500-001 WELD PLATES FOR SEPERATION BEAMS | | | #05-500-002 AMERICAN STAIR SHOP DRAWINGE7 OF E7 | | | #14-212-001 ELEVATOR PACK# 1, ELEVATOR PACK# 2, & | | | ELEVATOR PACK# 2 REVISED | | | #14-200-001 INCLINATOR SPECTRA-LIFT UNIT | | | 09-200-002 1HR FIRE RATED PARTITIONS | | | 08-500-001 PRODUCT APPROVALS WITH CALCS | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
29 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-22 |
Time |
07:58 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-08-16 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2007-08-16 18:58:36 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: | | | 03-250-006 | | | PTE 4TH-6TH MAIN TOWER PT DRGWS | | | | | | SUBMITTAL NO: | | | 03-250-005 | | | PTE 2ND TO 3RD LEVELS EAST TOWER | | | LOSS CALCULATIONS & SUPPORT PLAN | | | | | | SUBMITTAL NO: | | | 03-250-004 | | | PT 2ND-3RD MAIN BUILDING TOWER | | | | | | SUBMITTAL NO: | | | 03-250-003 | | | MEZZANINE POST TENSION PLAN | | | | | | SUBMITTAL NO: | | | 003-250-002 | | | CONCRETE PLASTIC HOLE FORMS/SLEEVES | | | | | | SUBMITTAL NO: | | | 03-250-001 | | | DOVETAIL ANCHOR 24 GAUGE | | | | | | SUBMITTAL NO: | | | 03-250-015 | | | REVISED POUR #1-5 3RD LEVEL REBAR | | | DAYS ELAPSED 13 | | | | | | SUBMITTAL NO: | | | 03-250-015 | | | REVISED POUR #1-5 3RD LEVEL REBAR | | | DAYS ELAPSED 28 | | | | | | SUBMITTAL NO: | | | 03-250-014 | | | PT CALCS/SHOPS 6TH DECK PARKING | | | LOSS CALCULATIONS | | | | | | SUBMITTAL NO: | | | 03-600-001 | | | F77 CONSTRUCTION GROUT | | | | | | SUBMITTAL NO: | | | 03-500-001 | | | ELEVATED DECK SHORING PLANS 20K | | | | | | BLDG SUBMITTAL: | | | SHORING/RESHORING INSPECTION REPORTS | | | 2ND LEVEL POURS # 01-05 | | | 3RD LEVEL POURS # 01-05 | | | 4TH LEVEL POURS # 01-05 | | | 5TH LEVEL POURS # 01-05 | | | 6TH LEVEL POURS # 01-05 | | | 7TH LEVEL POURS # 01-05 | | | 8TH LEVEL POURS # 01-05 | | | 9TH LEVEL POURS # 01-05 | | | 10TH LEVEL POURS # 01-05 | | | ROOF LEVEL POURS # 01-05 | | | | | | BLDG SUBMITTAL: | | | SHORING/RESHORING INSPECTION REPORTS | | | ROOF POURS # 1 - 5 | | | 10TH FLOOR POURS # 1 - 5 | | | 9TH FLOOR POUR # 5 | | | 5TH ELEVATED SLAB POUR # 1 | | | MEZZANINE GARAGE POUR # 2 | | | RAMP - MEZZANINE POUR # 2 | | | GARAGE LEVEL 2 POUR # 1 | | | GARAGE LEVEL 2 POUR # 2 | | | RAMP 2ND FLOOR TO 3RD FLOOR | | | | | | BLDG SUBMITTAL: | | | SHORING/RESHORING INSPECTION REPORTS | | | GARAGE RAMP LEVEL4TH TO 5TH FLOOR | | | GARAGE LEVEL5 POUR # 1 | | | GARAGE LEVEL 5 POUR # 2 | | | 4TH LEVEL POUR # 1 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
28 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-15 |
Time |
19:26 |
Rev Time |
4.44 |
| Received By |
jwitmer |
Date |
2007-08-15 |
Time |
17:18 |
Sent To |
|
|
| Notes |
| 2007-08-15 19:26:26 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: | | | 03-200-014 | | | AREA A SHEARWALLS 2ND-11TH LEVEL | | | REINFORCEMENT SHOP DRAWINGS | | | | | | SUBMITTAL NO: | | | 03-200-017 | | | REBAR MEZZANINE LEVEL POUR 1-5 SLAB | | | | | | SUBMITTAL NO: | | | 03-200-106 | | | 2ND FLOOR POUR 1-5 SLAB REBAR | | | | | | SUBMITTAL NO: | | | 03-200-015 | | | COLUMNS 2ND LEVEL - 11TH | | | | | | SUBMITTAL NO: | | | 03-200-019 | | | 4TH FLOOR P/T SLABS & BEAMS AREA "B" | | | | | | SUBMITTAL NO: | | | 03-200-021 | | | REBAR DRWGS 7TH FLOOR POURS 1-5 | | | | | | SUBMITTAL NO: | | | 03-250-010 | | | PT CABLE SHOP DRAWINGS OF ROOF | | | MAIN BUILDING TOWER & CALCULATIONS BY PTE | | | | | | SUBMITTAL NO: | | | 03-200-022 | | | GARAGE AREA "A" & "B" -WALLS @ RAMP | | | | | | SUBMITTAL NO: | | | 03-250-009 | | | PT CABLES ROOF EAST TOWER | | | LOSS CALCULATIONS & SUPPORT PLAN DRWG | | | | | | SUBMITTAL NO: | | | 03-200-018 | | | 5TH FLOOR P/T SLABS & BEAMS AREA "B" | | | | | | SUBMITTAL NO: | | | 03-250-007 | | | PTE 4TH TO 9TH LEVELS EAST TOWER PT | | | LOSS CALCULATIONS & SUPPORT PLAN | | | | | | SUBMITTAL NO: | | | 03-250-006 | | | PTE 4TH - 6TH MAIN TOWER PT DRWG | | | LOSS CALCULATIONS & SUPPORT PLAN | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
27 |
Status |
P |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-08 |
Time |
15:45 |
Rev Time |
5.55 |
| Received By |
jwitmer |
Date |
2007-08-08 |
Time |
15:45 |
Sent To |
PC |
|
| Notes |
| 2007-09-28 11:19:41 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION:DENIED | | | | | | SUBMITTAL NO: | | | ENGINEERS' SHORING LETTER | | | | | | GARAGE LEVEL 06 POOL NORTH POUR# 07 | | | | | | NOTARY NEEDS TO FILL OUT INFORMATION ON STAMP. | | | | | | J WITMER CBO | | | BUILDING PLAN REVIEWII | | 2007-08-08 16:46:21 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: REVIEWED | | | | | | SUBMITTAL NO: | | | 03-010-012 CORROSION INHIBITOR W? SUPER P 600 | | | 03-010-014 THIN-TOP SUPREME & CONCRETE EUCLID | | | 03-150-001 JAC FORM RELEASE AGENT | | | 03-015-002 FIBRE EXPANSION JOINT FILLER | | | 03-180-001 FORMWORK EPOXY ULTRABOND | | | | | | | | | 03-2000-001 SHOP DRAWING # 1 PARTIAL FOUNDATION AREA C | | | 03-200-002 WWM 8X20, 6X6 10/10 WIRE MESH 03-200-003 | | | SHOP DRAWINGS REBAR REINFORCING AREA A FIRST LIFT | | | VERTICALS | | | 03-200-004 REV 001 REBAR REINFORCING AREAB 1ST LIFT | | | REINFORCING BAR AREA B 1ST LIFT VERTICALS | | | REV REINFORCING AREA B 1ST LIFT | | | REVISE REINFORCING REBAR AREA B 1ST LIFT VERTICALS | | | 03-200-006 001 REBAR REINFORCING AREA B FNDTN SHOP | | | DRAWINGS | | | 03-200-005 REBAR REINFORCING- AREA A FOUNDATION SHOP | | | DRAWINGS | | | 03-200-007 REBAR REIN 1ST LIFT COLUMNS AREA C | | | 03-200-008 REBAR REINFORCING AREA A SHEARWALLS | | | 03-200-009 REBAR REINFORCING AREA B SHEARWALL | | | 03-200-010 MEZZ MAT AREA C TOP/ BOT BARS 03-200-011 | | | MEZZ BEAMS / SECTION AREA C | | | 03-200-012 REBAR REINF SHEARWALL AREA B 2ND-11 | | | 03-010-013 DWG FMI-1340 | | | 015-400-001 CHEM SEAL, HANGERS PIPES | | | 15-400-004 FIRESTOPPING SUNTECH PLUMBING 15-400-009 | | | 7TH-8TH LEVEL PENETRATION SHOP DRAWINGS 15-400-010 | | | PROGRESS SUBMITTALS | | | 15. SPECIFICATIONS OF STUDRAILS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
26 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-07 |
Time |
12:56 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-07 |
Time |
12:56 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 12:59:51 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | ) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | ACTION: DENIED | | | | | | REVISION : GARGE DOOR- BEST ROLLING DOOR MODEL | | | S10-6065 | | | | | | 1) THIS IS NOT S SUBMITTAL BUT A REVISION WITH | | | ASSCIATED FEES, A $60.00 FEE HAS BEEN ATTACHED CODED | | | (0808) REVISION# 8. | | | THE ISSUED SET OF PLANS HADCORNELL ROLL-UP EXTERIOR | | | DOOR FL # 5416 FOR A PRODUCT APPROVAL. | | | THE SUBMITTED BESST ROLLING DOORS IS MISSING THE | | | FLORIDA COVERSHEET.PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED | | | TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE SEE THE | | | STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A | | | COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE STATE. IF THE | | | PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT AN | | | APPLICATION FOR LOCAL PRODUCT APPROVAL OR SITE SPECIFIC | | | FORM PER RULE 9B-72. | | | | | | 2) PLEASE HAVE AT LEAST ONE SET OF PRODUCT APPROVALS | | | WITH THE ORIGINAL SHOP DRAWING STAMP BE AN ORIGINAL ON | | | THE PRODUCT APPROVAL ITSELF, NOT A BLANK PAPER. THIS | | | WILL TIE BACK TO THE PRODUCT APPROVAL BEING REVIEWED. | | | ADDITIONAL INFORMATION REQUIRED 106.1.2. | | | | | | 3) THE PRODUCT TESTING SHEET # 4 HIGHLIGHT WHICHSYSTEMS | | | TO BE USED IN THE INSTALATION, TO BE REVIEWED BY THE | | | DESIGNER OF RECORD.WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE REGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
25 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-07 |
Time |
11:22 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-07 |
Time |
11:22 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 11:49:17 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO:TRANSMITTAL# 01465 | | | REFERENCE: SHIM GAP SLIDING GLASS DOORS | | | R. C. ALUMINUM SERIES 2400 ST SLIDING GLASS DOORS NOA | | | 01-0927.05 | | | THIS PRODUCT APPROVAL STATES: | | | NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS | | | 3. LIMITATIONS | | | 3.1 THIS APPROVAL APPLIES TO SINGLE UNIT APPLICATIONS, | | | AS SHOWN APPROVED DRAWINGS. | | | 4. LIMITATIONS | | | 4.1 THE ALUMINUM SLIDING GLASS DOOR AND ITS COMPONENTS | | | SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE | | | APPROVED DRAWINGS. | | | | | | 1) THE TRCHNICAL SHEET 1 OF 6 PROVIDES THE DESIGN LOADS | | | WITH 1/4", 3/8" AND 1/2" SHIM ROOM, INTO THRESS TYPE OF | | | SUBSTRATE THRU WOOD BUCKS DIRECTLY INTO MASONRY, | | | DIRECTLY INTO MASONRY AND INTO METAL STRUCTURES. | | | | | | 2) THE PRODUCT APPROVAL WAS TESTED IN STRICT COMPLIANCE | | | WITH TAS-201, TAS-202 AND TAS-203 THE TEST CRITERIA AND | | | LIMITATIONS ARE LISTED IN THE PRODUCT APPROVAL AND CAN | | | NOT BE EXCEEDED. | | | | | | 1714.5.2.1 TESTING AND LABELING. | | | EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN | | | APPROVED INDEPENDENT TESTING LABORATORY, AND SHALL BE | | | LABELED WITH AN APPROVED LABEL IDENTIFYING THE | | | MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED | | | PRODUCT CERTIFICATION AGENCY, TESTING LABORATORY, | | | EVALUATION ENTITY OR MIAMI-DADE PRODUCT APPROVAL TO | | | INDICATE COMPLIANCE WITH THE REQUIREMENTS OF ONE OF THE | | | FOLLOWING SPECIFICATIONS: | | | ANSI/AAMA/NWWDA 101/I.S.2 OR 101/I.S. 2/NAFS OR | | | AAMA/WDMA/CSA 101/I.S.2/A440 OR TAS 202 (HVHZ SHALL | | | COMPLY WITH TAS 202 UTILIZING ASTM E 1300 -98 OR ASTM E | | | 1300-02 OR SECTION 2404 . ) | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
24 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-07 |
Time |
08:32 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-07 |
Time |
08:32 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 08:40:56 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | SUBMITTAL NO: 05-500-020 | | | | | | 1) GENERAL NOTES, GOVERNING CODE: | | | PLANS INDICATE THAT THE PLANS WERE DESIGNED TO | | | WITHSTAND THE LOADS OF THE APPLICABLE LOADS, NOT THE | | | 2004 FBC, PLEASE CORRECT. | | | | | | 2) ONE OF THE CONCERNS IS THAT THE SHOP DRAWING SIGNED | | | BY THEDESIGN TEAM IS NOT ON ANY OF THE ACTUAL | | | DRAWINGS TO BE REVIEWED. PLEASE HAVE THE DESIGN TEAM | | | PLACE STAMP ON THE SHOP DRAWINGS TO BE REVIEWED. ALSO | | | PROVIDE ONE ORIGANAL STAMPED AND SIGNED DRAWING IN EACH | | | SUBMITTAL 2 COPIES WILL BE SENT BACK TO THE FIELD. | | | 106.1.2.* ADDITIONAL INFORMATION REQUIRED. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
23 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-07 |
Time |
07:58 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-07 |
Time |
07:58 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 08:22:09 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO: 05-500-017 | | | | | | ACTION: DENIED | | | | | | REFRENECE: LOUVERS | | | | | | 1) PLEASE PROVIDE THE LOCATION WHERE THISA LOUVER WILL | | | BE PLACED ON THE BUILDING. ADDITIONAL INFORMATION | | | REQUIRED.106.1.2. | | | | | | 2)2004 FL. BLD CODE 1603.1.4 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE SHOWN ON THE | | | CONSTRUCTION DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | 3) RULE 9B-72 REQUIRES LOUVERS TO BE TESTED FOR WIND, | | | PLEASE PROVIDE THE TESTING REPORT FROM EITHER FLORIDA | | | WEBSITE OR A MIAMI-DADE NOA,(NOTICE OF ACCEPTANCE). | | | RULE 9B-72 REQUIRES THIRD PARTY QUALITY ASSURANCE | | | PROGRAM BY AN AGENCY LISTED ON THE STATE WEBSITE BOTH | | | THE MIAMI-DADE AND STATE WEBSITE HAVE THIRD PARTY | | | QUALITY ASSURANCE PROGRAMS. IF THE MANUFACTURER HASN'T | | | WENT FOR PRODUCT APPROVAL | | | AT EITHER OF THESE AGENCIES, THEY MAY APPLY FOR LOCAL | | | PRODUCT APPROVAL. LOCAL PRODUCT APPROVAL WILL ALSO | | | REQUIRE THIRD PARTY QUALITY ASSURANCE PROGRAM. | | | PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A | | | COVER SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM | | | THE STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE | | | APPROVAL, SUBMIT AN APPLICATION FOR LOCAL PRODUCT | | | APPROVAL OR SITE SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
22 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-07 |
Time |
07:51 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-07 |
Time |
07:51 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 07:56:39 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO: 05-500-019 | | | | | | DENIED | | | REFRENCE: SEALED SHOP DRAWINGS FOR ROOF BRACKETS | | | | | | THE ROOF BRACKET SHEET CREATED BY POMA INDICATES (2) | | | BACKER BLOCKS F & G, THE PLANS INDICATE HOW THEY ARE | | | ATTACHED TO THE WALLAND SOFFIT BUT NOT TO THE BRAKET | | | (A). | | | PLEASE PROVIDE ADDITIONAL INFORMATION 106.1.2*. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
21 |
Status |
F |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-07 |
Time |
07:27 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-07 |
Time |
07:26 |
Sent To |
PC |
|
| Notes |
| 2007-08-07 07:33:22 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO:05-500-018 | | | | | | DENIED: | | | | | | EGG CRATE AWNINGS: | | | 1) PLEASE PROVIDE WHERE THESE AWNINGS WILL BE PLACED ON | | | THE BUILDING, AT WHAT HEIGTH? PLEASE INDICATE ON WHAT | | | SHEET OF THE PLAN AND LOCATION.ADDITIONAL INFORMATION | | | REQUIRED 106.1.2.* | | | | | | 2) PLEASE PROVIDE THE DESIGN CRITERIA FOR THE AWNINGS | | | ALSO. 2004 FL. BLD CODE 1603.1.4 THE FOLLOWING | | | INFORMATION RELATED TO WIND SHALL BE SHOWN ON THE | | | CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | | CATEGORY | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
20 |
Status |
P |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
10:13 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
10:13 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 10:36:45 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO: SHORING/ RE-SHORING | | | REVIEWED | | | SECOND LEVEL GARAGE POUR# 1 | | | MEZZANINE GARAGE LEVEL POUR# 2 | | | MEZZANINE GARAGE LEVEL POUR# 1 | | | GARAGE LEVEL 04 POUR# 3 | | | 4TH FLOOR POUR# 3 | | | SECOND LEVEL GARAGE POUR# 02 | | | GARAGE LEVEL3 2, POUR# 2 | | | GARAGE LEVEL# 03 POUR# 02 | | | 3RD FLOOR POUR# 2 | | | GARAGE LEVEL# 03, POUR# 01 | | | 3RD FLOOR, POUR 1 | | | GARAGE RAMP LEVEL 03 TO 04 | | | RAMP 3RD TO 4TH FLOOR | | | 4TH FLOOR POUR# 2 | | | GARAGE RAMP LEVEL 02 TO 03 | | | GARAGE LEVEL 04 POUR# 02 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
19 |
Status |
P |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
09:54 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
09:54 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 09:56:12 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO: 05-500-021 | | | REVIEWED : | | | TRELLIS SHOP DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
18 |
Status |
P |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
09:03 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
09:03 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 09:44:39 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO:SHORING | | | REVIEWED: | | | 20K LAYOUT TYPICAL GARAGE PLAN VIEW | | | DECK 6TH PARKING- TENDON & SUPPORT PLAN | | | ROOF WEST TOWER UNIFORMS AND SUPPORTS | | | FIRST LEVEL- MEZZANINE SUPPORT PLAN | | | PT FRICTION LOSS CALS PTE STRAND 1 ST LEVEL PARKING | | | MEZZANINE SHOP DRAWING | | | PT CALCS SHOP 2-4TH FLOOR PARKING | | | PTE STRAND FRICTION LOSS CALCS SHOP DRAWING 2ND-4TH OF | | | THE PARKING GARAGE | | | PT CALCS SHOP 5TH FLOOR PARKING | | | PTE STRAND FRICTION LOSS CALS FOR 5TH FLOOR PARKING | | | GARAGE AND SHOP DRAWINGS | | | TWS (METAL TRUSSES) LAYOUT FRAMING PLAN | | | SCOSTA CORP STEEL ROOF LAYOUT PLAN SCOSTA CORP COLD | | | FORMED STEEL TRUSS PACKET 1 SET/ CITY SET |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
17 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
08:37 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
08:37 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 08:44:42 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO: 09-200-003 | | | | | | DENIED | | | | | | PLEASE PROVIDE MORE INFORMATION AS TO WHAT THIS | | | SUBMITTAL IS DOING? IF THIS IS SUBSTITUTING DENSEGLASS | | | FOR M.R. G. W.B. PLEASE INDICATE SUCH WITH A REVISION | | | TO SHEET A.8 FOR THIS IS A REVISION. IF THIS IS TO ONLY | | | OCCUR AT THE ELECTRICAL METER ROOMS CREATE A NEW WALL | | | TYPE FOR SHEET 8.0, IN EITHER CASE THIS WILL BE A | | | REVISION WWITH ASSCIATED FEES AND NEW ARCHITECTURAL | | | SHEET. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
16 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
08:28 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
08:28 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 08:31:59 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO:05-700-001 | | | REVISION NO: | | | DENIED | | | | | | THE SHOP REVIEW STAMP FROM THE DESIGNER OF RECORD ON | | | ALL THREE SUBMITTALS ARE COPIES, NEED AT LEAST ONE | | | ORIGINAL SIGNED BY THE DESIGNER OF RECORD. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
15 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
08:20 |
Sent To |
B |
|
| Notes |
| 2007-08-06 08:24:08 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO: 05-500-003 | | | REVISION NO: | | | DENIED | | | | | | THE SHOP REVIEW STAMP FROM THE DESIGNER OF RECORD ON | | | ALL THREE SUBMITTALS ARE COPIES, NEED AT LEAST ONE | | | ORIGINAL SIGNED BY THE DESIGNER OF RECORD. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
14 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
07:57 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
07:57 |
Sent To |
PC |
|
| Notes |
| 2007-08-06 08:15:17 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO:05-500-023 SS POOL GATE SHOP DRAWINGS | | | REVISION NO: | | | DENIED | | | | | | PLEASE PROVIDE DETAILS FOR THE MAGMA LATCH (GATE LOCK) | | | INDICATE COMPLIANCE WITH 424.1.3.1.9 SELF LATCHING . | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
13 |
Status |
F |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-06 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-08-06 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2007-08-06 07:55:40 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO:05-500-025 | | | REVISION NO: | | | DENIED | | | S.S. CLOCK TOWER LOUVER SHOP DRAWINGS | | | | | | THE PRODUCT APPROVALS SUBMITTED FOR LOUVERS DOES NOT | | | INDICATE POMA CORPARATION AS ONE OF THE MANUFACTURERS, | | | PLEASE SUBMIT THE FLORIDA APRROVAL OR MIAMI-DADE REPORT | | | WHICH BOTH HAVE THE REQUIRED THIRD PARTY QUALITY | | | ASSURANCE PROGRAM. | | | IF THE CONTRACTOR IS GOING TO TRY TO SUBMIT POMA | | | LOUVERS PROVIDE THE REQUIRED THIRD PARTY QUALITY | | | ASSURANCE PROGRAM REQUIRED FOR STATE AS WELL | | | AS FOR LOCAL APPROVAL. IF THE MANUFACTURER IS TO SUBMIT | | | FOR LOCAL APPROVAL PLEASE CONTACT THIS OFFICE FOR MORE | | | INFORMATION AND REQUIREDFORMS. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
12 |
Status |
F |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-03 |
Time |
16:24 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-03 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2007-08-03 16:55:59 | | | | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | SUBMITTAL NO: 15-700-007 | | | S.S. COLONIAL SHUTTERS/ LSAL AWNINGS | | | REVISION NO: | | | | | | DENIED: | | | | | | 1) SEE SHEET A4.0 AND A4.1 OF PLANS ALL BAHAMA TYPE | | | SHUTTERS TO BE UNDER SEPEERATE PERMIT WITH ASSCIATED | | | FEES AND REVIEWS. | | | | | | 2) FIXED ALUMINUM LOUVERS, THE PLAN DOES NOT INDICATE | | | THELOCATION ON THE BUILDING, SHEET 4OF 4 INDICATES | | | SEPERATE SHAPES OF ALUMINUM EXTRUSIONSBUT NO REASON WHY | | | THEY ARE SHOWN, | | | IS THIS TO BE FIXED FLAT AGAINST THE WALL? 106.1.2* | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
11 |
Status |
P |
Date |
2007-08-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-03 |
Time |
13:06 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-08-03 |
Time |
13:06 |
Sent To |
PC |
|
| Notes |
| 2007-08-03 15:04:49 | ARDAMAN RAILING LOAD TEAT: POMA & SONS PROTOTYPE PICKET | | | RAILING SYSTEM | | | SUBMITTAL # 05-500-022 S.S. SITE FENCE SHOP DRAWING | | | SUBMITTAL # 05-500-24PROPERTY FENCE |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
10 |
Status |
F |
Date |
2007-07-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-07-12 |
Time |
16:39 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-07-12 |
Time |
16:39 |
Sent To |
PC |
|
| Notes |
| 2007-07-12 16:47:13 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 480 HIBISCUS ST | | | CONT: THE TOWER GROUP | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | STAIR CALCS & SHOP DRAWING REVIEW | | | ACTION: DENIED | | | | | | 1)SHOP DRAWINGS BY COHEN FREEDMAN ENCINOSA HAVE A | | | PHOTO COPIED SEAL ANS OR PHOTO COPIED SIGNATURE. | | | THE RAISED SEAL IS NOT SIGNED NOR DATED. | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN | | | PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-07 |
Time |
13:23 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-05-07 |
Time |
13:23 |
Sent To |
PC |
|
| Notes |
| 2007-05-07 13:40:13 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 480 HIBISCUS ST | | | CONT: THE TOWER GROUP | | | TEL: (954)275-3592 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | THE SHORING / RESHORING INSPECTION REPORTS SUBMITTED TO | | | THE CITY OF WEST PALM BEACH BY GARY BROWN ARE COPIES. | | | DATED FROM NOV. 16, 2006 -APRIL 24, 2007. | | | THESE REPORTS BEING COPIED WITH A NOTARY SEAL CREATES A | | | SECOND DEGREE MISDEMEANOR, PUNISHABLE AS PROVIDED IN | | | S.775.082 OR S 775.083. | | | | | | 117.05((3)(E)ANY PERSON WHO UNLAWFULLY POSSESSES A | | | NOTARY PUBLIC OFFICIAL SEAL OR ANY PAPERS OR COPIES | | | RELATING TO NOTARIAL ACTS IS GUILTY OF A MISDEMEANOR OF | | | THE SECOND DEGREE, PUNISHABLE AS PROVIDED IN S. 775.082 | | | OR S. 775.083. | | | | | | COPIES OF SAID DOCUMENTS WILL BE MAINTAINED AS EVIDENCE | | | THAT MAY BE FORWARDED TO THE GOVERNORS NOTARY BOARD FOR | | | DISCIPLINARY ACTIONS IF COPIES ARE SUBMITTED AGAIN TO | | | THE CITY! | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-07 |
Time |
11:58 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2007-05-07 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2007-05-07 12:03:20 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 480 HIBISCUS ST | | | CONT: THE TOWER GROUP | | | TEL: (954)275-3592 | | | | | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 5TH ELEVATED SLAB, POUR # 1 REPORT IS A COPIED | | | SIGNATURE WITH RAISED SEAL. PLANS, SPECIFICATIONS, | | | REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND | | | BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-07 |
Time |
11:58 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-05-07 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2007-05-07 11:57:55 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 480 HIBISCUS ST | | | CONT: THE TOWER GROUP, INC | | | TEL: (954)275-3592 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: | | | SHORING & RESHORINGLETTERS; | | | 1ST ELEVATION POUR 1-5 MEZZANINE LEVEL | | | 2ND ELEVATION POUR 1-5 | | | 3RD ELEVATION POUR 1-5 | | | 4TH ELEVATION POUR 1-5 | | | 5TH ELEVATION POUR 2-5NOTE: 5HT ELEVATIONPOUR# 1 | | | DENIED COPIED | | | 6HT ELEVATION POUR 1-5 | | | 7TH ELEVATION POUR 1-5 | | | 8TH ELEVATION POUR 1-2 | | | POUR 1, MEZZANINE 2, GARAGE | | | 9TH ELEVATION POUR 2-4 | | | 8TH ELEVATION POUR 5 | | | 9TH ELEVATION POUR 1 | | | L | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-03-19 |
Time |
08:47 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-03-19 |
Time |
08:47 |
Sent To |
PC |
|
| Notes |
| 2007-03-19 09:23:57 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 480 HIBISCUS ST | | | CONT: THE TOWER GROUP | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | ROOFREVIEW-METAL ROOF " | | | COPPER SALES UC-3 STANDING SEAM METAL ROOF PANELS ON | | | 22GA. B-DECK | | | | | | ACTION: REVIEWED | | | | | | | | | NOTICE:3-19-07AT THIS TIME NO ROOFING PERMIT HAS BEEN | | | APPLIED FOR, | | | BEFORE A ROOFING PERMIT CAN BE ISSUED, THE FLAT ROOF | | | REPORT SUBMITTED | | | | | | BEFORE THE ROOFING CONTRACTOR WILL BE ISSUED A ROOFING | | | PERMIT THEJOHNS MANVILLE MODIFIED BITUMEN ROOFING | | | OVER LIGHTWEIGHT CONCRETE DECKS WILL NEED TO PICK A | | | SUB-SYSTEM, THE SUBSYSTEM IN MOST CASES WILL REQUIRE | | | ENHANCED FASTENING SYSTEMS. LIGHTWEIGHT INSULATING | | | CONCRETE SYSTEMS REQUIRE CALCULATIONS FROM AN AARCHITEC | | | OR ENGINEER. SEE ACTUAL LIMITATION SHEET. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2006-12-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-12-06 |
Time |
10:51 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-12-06 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2006-12-06 10:54:08 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 430 HIBISCUS ST. | | | CONT: THE TOWER GROUP | | | TEL: (561)635-6935 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | BUILDING PROVISO FOR REVISION DATED OR MARKED # 10. | | | | | | 1) SHEET A3.5 INDICATES A NEW LOUVER WITH A M.O. OF | | | 8'-6" X 15'-0" THE LOUVERS | | | SUBMITTED UNDER THE PRODUCT APPROVALS WILL NOT MEET | | | THIS SIZE. PLEASE CORRECT | | | OR PROVIDE ADDITIONAL INFORMATION.LOUVER SERIES | | | SUBMITTED: | | | CONSTRUCTION SPECIALTIES, INC. | | | 7000 SERIES LOUVER NOA 00-1107.03 | | | DC 5304 LOUVER 02-0621.03 | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-28 |
Time |
09:58 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2006-08-28 |
Time |
09:58 |
Sent To |
|
|
| Notes |
| 2006-08-28 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 430 HIBISCUS | | | CONT:PROJECT | | | TEL: (561)586-2913 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | ARCHITECT: COHEN, FREEDMAN, ENCINOSA | | | & ASSOC. STUART COHEN/ GULLERMO ENCINOSA | | | 8085 N. W. 155 ST | | | MIAMI, FL | | | T(305)826-4155 | | | | | | STRUCTURAL: DE LOS REYESENGINEERING, INC | | | 8726 S. W. 26 TH STREET SUITE 1&2 | | | HECTOR DE LOS REYES | | | MIAMI, FL | | | T(305)477-8826 | | | | | | | | | ***BUILDING PROVISO*** | | | | | | 1) WITHIN 30 WORKING DAYS OF PERMIT | | | ISSUANCE THE STRUCTRAL ENGINEER SUBMITS | | | REVISIONS INDICATING THE BUILDING IS | | | DESIGNED TO ASCE 7-02. | | | | | | 2) 109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | | ACTIVITY REGULATED BY THIS | | | CODE SHALL BE PERMORMED IN A MANNER SO | | | AS NOT TO ADVERSELY IMPACT THE CONDITION | | | OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID | | | PROPERTY PURSUANT TO A CONSENT BY THE | | | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE | | | PROPERTY OWNER.THIS INCLUDES BUT IS NOT | | | LIMITED TO THE CONTROL OF DUST, NOISE, | | | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. | | | NEW CONSTRUCTION ACTIVITY SHALL NOT | | | ADVERSELY IMPACT HISTORIC SURFACE WATER | | | DRAINAGE FLOWS SERVING ADJACENT | | | PROPERTIES, & MAY REQUIRE SPECIAL | | | DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, | | | AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR | | | ITEMS, ON EXISTING PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF | | | PERMEABLE LAND AREA ON ANY PARCELL SHALL | | | AS A PERMIT CONDITION, PROVIDE A | | | PROFESSIONALLY PREPARED DRAINAGE PLAN | | | CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 3) 109.3.10.1 HURICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-08-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-08-02 |
Time |
12:16 |
Rev Time |
7.77 |
| Received By |
jwitmer |
Date |
2006-08-01 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 430 HIBISCUS | | | CONT:PROJECT | | | TEL: (561)586-2913 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | ARCHITECT: COHEN, FREEDMAN, ENCINOSA | | | & ASSOC. STUART COHEN/ GULLERMO ENCINOSA | | | 8085 N. W. 155 ST | | | MIAMI, FL | | | T(305)826-4155 | | | | | | STRUCTURAL: DE LOS REYESENGINEERING, INC | | | 8726 S. W. 26 TH STREET SUITE 1&2 | | | HECTOR DE LOS REYES | | | MIAMI, FL | | | T(305)477-8826 | | | | | | 3RD REVIEW | | | ACTION: DENIED | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | 1) COMPLIED | | | | | | 2) COMPLIED | | | | | | 3) THIS WILL BE A NEW REQUEST SINCE THE | | | REDESIGN OF THE CLUBHOUSE. AS DISCUSSED | | | EARLIER IN PREVIOUS MEETINGS, A 2 HR | | | FIRE RATING WILL NEED TO BE PROVIDED FOR | | | THE STEEL ROOF FRAMING MEMBERS. TO DATE | | | NO INFORMATION HAS BEEN PROVIDED. | | | | | | 4) 2ND REQUEST, MOST OF THE SUBMITTALS | | | ARE FILED UNDER THE 2001 FBC, THIS | | | PROJECT IS FILED UNDER THE 2004 FBC, | | | PLEASE SCROLL THROUGH THE 2004 REPORTS. | | | NOT ALL PRODUCTS FILED UNDER THE 2001 | | | MEET THE 2004 STANDARDS. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5) 3RD REQUEST, FL BLD CODE 1606.1.5: | | | COMPONENTS & CLADDING, PROVIDE 2 | | | COPIES(3 IF THRESH- OLD OR RESIDENT | | | INSPECTOR) OF PRODUCT TESTING | | | REPORTS,MISSING REPORTS ARE AS FOLLOWS: | | | A) EXTERIOR FIXED WINDOWS | | | RC ALUMINIUM SUBMITED 2001 APPROVAL, | | | SERIES FX 345 NOT FOUND UNDER THE | | | FBC 2004. PLEASE HIGHLIGHT TYPE OF | | | GLASS IF MULTIPLE SYSTEMS AVAILABLE. | | | B) EXTERIOR WINDOWS OPERATABLE: | | | RC ALUMINIUM SUBMITTED 2001 APPROVAL, | | | C) MULLIONS: MAY OR MAY NOT BE INCLUDED | | | | | | IN NOA DEPENDING ON SPANS. | | | D) EXTERIOR GLAZED DOORS: | | | RC ALUMINIUM SUBMITTED 2001 APPROVAL | | | E) EXTERIOR ROLL UP DOORS: | | | CORNELL IRON WORKS, IS MISSING THE | | | EVALUAATION REPORT ER-05-0003 | | | PAGES 1-3, PLUS 23 TECHNICAL SHEETS. | | | HIGHLIGHT WHICH TABLE (PSF) AND SPANS | | | | | | USED. | | | F) EXTERIOR SWING DOORS: | | | BARON METAL IND. INC. 2004 COVERSHEET | | | TIES TO THE NOA 04-0330.01 NOT THE | | | REPORT SUBMITTED. NOTE REPORT IS ONLY | | | | | | GOOD FOR +/-75 PSF. END PRESSURES ARE | | | | | | PROFESSIONALS STAMP REVIEWED IF | | | PRODUCT DOESN'T WORK!!!!! | | | G) LOUVER: SUBMITTED 2001 REPORT. | | | H) SHUTTERS: HURST PRINT OUT CURRENT | | | REPORTTHAT IS APPROVED, SUBMITTED | | | STATES PENDING.SUBMIT THE CURRENT NOA | | | THAT TIES TO THIS REPORT. THE ONE | | | SUBMITTED IS EXPIRED. | | | I) ROOFING ASSEMBLIES: | | | MODIFIED, PLEASE HIGHLIGHT WHICH | | | SUBSYSTEM TO BE USED. PLEASE CHECK | | | COMPONENTS TO MATCH SUBSYSTEM. ALSO | | | SEE NOTE# 7 SYSTEMS LIMITATION & RAS | | | 117 CALCULATIONS FOR ADDITIONAL | | | FASTENING. | | | J) METAL ROOFING, SUBMITTED 2001 REPORT, | | | HIGHLIGHT SUBSYSTEM TO BE USED. | | | K) TRUSS ANCHOR NO REPORT SUBMITTED | | | L) EXTERIOR RAILINGS: NO REPORT | | | SUBMITTED | | | 6) ENERGY CALCS BOTH 2001 AND 2004 CALCS | | | | | | HAVE BEEN SUBMITTED. | | | | | | 7) ONLY ONE SET OF SOILS REPORT | | | SUBMITTED, COPIED NOT SEALED. | | | PLANS, SPECIFICATIONS, REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 8)STRUCTURAL PLANS: | | | RULE 61G155-23.001(1) F.A.C. | | | THE FLORIDA BOARD OF PROFESSIONAL | | | ENGINEERS HAS CLEANED UP THE APPEARANCE | | | OF THE SEAL BY ELIMINATING OBSOLETE | | | CONTENT AND CHANGING THE WORD | | | "CERTIFICATE" TO "LICENSE". A GRACE | | | PERIOD RAN THROUGH DEC. 31,2005. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2006-04-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2006-04-14 |
Time |
12:58 |
Rev Time |
8.88 |
| Received By |
jwitmer |
Date |
2006-04-13 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2006-04-14 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 430 HIBISCUS | | | CONT:PROJECT | | | TEL: (561)586-2913 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | ARCHITECT: COHEN, FREEDMAN, ENCINOSA | | | & ASSOC. STUART COHEN/ GULLERMO ENCINOSA | | | 8085 N. W. 155 ST | | | MIAMI, FL | | | T(305)826-4155 | | | | | | STRUCTURAL: DE LOS REYESENGINEERING, INC | | | 8726 S. W. 26 TH STREET SUITE 1&2 | | | HECTOR DE LOS REYES | | | MIAMI, FL | | | T(305)477-8826 | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 1) COMMENT# 21 FROM THE PREVIOUS REVIEW, | | | A0.4 MEZZANINE LEVEL PROVIE THE | | | SQUARE FOOT OF EACH COMMERCIAL TEANANT | | | FOR THE FIRST FLOOR LEVEL AS WELL AS THE | | | MEZZANINE LEVEL. 505.2 AREA LIMITATION. | | | THE AGGREGATE AREA OF A MEZZANINE OR | | | MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. IN DETERMINING THE ALLOWABLE | | | MEZZANINE AREA, THE AREA OF THE | | | MEZZANINE SHALL NOT BE INCLUDED IN THE | | | AREA OF THE ROOM. | | | 1A) REVIEW THE SQ FT FOR FIRST FLOOR AND | | | TOTAL FOR COMMERCIAL #1 & #2. | | | 1B) COMMERCIAL UNIT# 8 PLEASE | | | RECALCULATE THE MEZZANINE LEVEL IT | | | APPEARS TO BE OVER THE 1/3RD BY 20 SQ | | | FT. | | | NOTE!!!!!! 110.2* (F) THIS WILL BE A | | | BUILDING SITULATION THAT MUST APPEAR ON | | | THE C.O.!!!!!!!!!!!!! | | | FBC 505.2 COMMERCIAL BUILDOUTS, NO WALLS | | | CAN BE ADDED BENEATH THE MEZZANINE | | | LEVEL.THE AGGREGATE AREA OF A MEZZANINE | | | OR MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. | | | | | | 2) COMMENET# 22B) FROM THE PREVIOUS | | | REVIEW, DOOR 14 & 36 BOTH ARE OVERHEAD | | | DOORS ON THE REFUSE ROOMS. 707.1.13.4 | | | DOORS TO BE 3/4 HR AND SELF CLOSING OR | | | AUTOMATICALLY TO CLOSE IF SMOKE IS | | | DETECTED. HOW OR WHAT TYPE OF DEVICE | | | WILL ACCOMPLISH THIS ACTION? PROVIDE | | | SPEC SHEETS. | | | | | | 3) COMMENT# 28D) THE HEALTH CLUB NOW | | | INDICATES THE USE OF HEAVY TIMBER AND 1 | | | 1/2 WOOD DECKING, TABLE 601 FORA TYPE | | | 1A CONSTRUCTION FOR ROOF CONSTRUCTION | | | INCLUDING SUPPORTING BEAMS AND JOIST | | | REQUIRE A 1 1/2 HR FIRE RESISTANCE | | | RATING. FOOTNOTE "C"(2)(III)TYPE "1" | | | OVER 2 STORIES DOES ALLOW FRT WOOD IF A | | | 20' CLEAR FROM THE UPPER FLOOR TO THE | | | ROOFIS ALLOWED AS IN THE PENTHOUSE | | | UNITS. THIS CASSE THERE IS N'T 20'-0" | | | CLEAR.ALSO SEE 602.2 TYPE I & II. | | | | | | 4) COMMENT# 31 FROM THE PREVIOUS REVIEW, | | | | | | 31) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 5) COMMENT# 32 FROM THE PREVIOUS REVIEW | | | 32)W P B ADMINISTRTIVE CODE 106.3.3* | | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 6) COMMENT# 33 FROM THE PREVIOUS REVIEW | | | 33) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) EXTERIOR WINDOWS FIXED | | | B) EXTERIOR WINDOWS OPERATABLE | | | C) MULLIONS | | | D) EXTERIOR GLAZED DOORS | | | E) EXTERIOR ROLL UP DOORS | | | F) LOUVERS | | | G) TRUSS ANCHOR ATTACHMENTS | | | H) STORM SHUTTERS | | | I) EFIS SYSTEMS | | | J) EXTERIOR RAILINGS | | | K) ROOFING ASSEMBLIES FLAT AND SLOPED | | | ALL OF THE ABOVE MENTIONED PRODUCTS | | | WILL REQUIRE THE DESIGNER OF RECORD TO | | | SIGN OFF THAT THE REPORTS HAVE BEEN | | | REVIEWEDAND APROVED BY THEIR OFFICE. | | | | | | ---NEW COMMENTS--- | | | | | | 7)1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING | | | ASSEMBLIES SEPARATING DWELLING UNITS | | | FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND | | | TRANSMISSION CLASS (STC) OF NOT LESS | | | THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 90. PENETRATIONS | | | OR OPENINGS IN CONSTRUCTION ASSEMBLIES | | | FOR PIPING; ELECTRICAL DEVICES; RECESSED | | | CABINETS; BATHTUBS; SOFFITS; OR HEATING, | | | VENTILATING OR EXHAUST DUCTS SHALL BE | | | SEALED, LINED, INSULATED OR OTHERWISE | | | TREATED TO MAINTAIN THE REQUIRED | | | RATINGS. THIS REQUIREMENT SHALL NOT | | | APPLY TO DWELLING UNIT ENTRANCE DOORS; | | | HOWEVER, SUCH DOORS SHALL BE TIGHT | | | FITTING TO THE FRAME AND SILL. | | | | | | 8) 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN | | | DWELLING UNITS OR BETWEEN A DWELLING | | | UNIT AND A PUBLIC OR SERVICE AREA WITHIN | | | THE STRUCTURE SHALL HAVE AN IMPACT | | | INSULATION CLASS (IIC) RATING OF NOT | | | LESS THAN 50 (45 IF FIELD TESTED) WHEN | | | TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2006-01-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-01-20 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2006-08-01 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2006-01-17 00:00:00 | BUILDING PLAN REVIEW | | | PERMIT: 05091265 | | | ADD: 430 HIBISCUS | | | CONT:PROJECT | | | TEL: (561)586-2913 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | * WEST PALM BEACH AMENDMENTS | | | | | | ARCHITECT: COHEN, FREEDMAN, ENCINOSA | | | & ASSOC. STUART COHEN/ GULLERMO ENCINOSA | | | 8085 N. W. 155 ST | | | MIAMI, FL | | | T(305)826-4155 | | | | | | STRUCTURAL: DE LOS REYESENGINEERING, INC | | | 8726 S. W. 26 TH STREET SUITE 1&2 | | | HECTOR DE LOS REYES | | | MIAMI, FL | | | T(305)477-8826 | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | COMMENTS FROM THE FOUNDATION PERMIT WILL | | | ALSO APPLY TO THIS PERMIT AS WELL. | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | FROM FOUNDATION PERMIT: | | | 1) PROVIDE NOC RECORDED WITH THE CLERK | | | OF COURT BEFORE A PERMIT CAN BE ISSUED. | | | NOTE: 713.13.(2) IF WORK HASN'T STARTED | | | WITHIN 90 DAYS OF THE NOC BEING RECORDED | | | SUCH NOTICE WILL BE VOID AND NO FURTHER | | | IN EFFECT CAUSING IT TO BE RE-RECORDED. | | | | | | 2) THERE SEEMS TO BE A DISCREPANCY | | | BETWEEN THE PERMIT APPLICATION AND PLANS | | | AS TO THE ADDRESS AS WELL AS THE | | | PROPERTY CONTROL NUMBER. | | | 2A) PERMIT APPLICATION INDICATES 430 | | | HIBISCUS WHERE AS THE PLANS INDICATE 480 | | | HIBISCUS. | | | 2B) THE PCN SUPPLIED ON THE PERMIT | | | APPLICATION INDICATES A SINGLE LOT. A0.2 | | | APPEARS TO TAKE MOST OF THE BLOCK AND | | | CROSSING THE ALLEYWAY. PROVIDE A REPLAT | | | INDICATING A SINGLE LOT AND NEW PCN. | | | 2C) BEFORE THE FOUNDATION PLAN IS | | | RESUBMITTED CORRALATE ALL PLANS INTO | | | THREE COMPLETE SETS AND STAPLED. | | | 106.1.2 ADDITIONAL DATA. THE BUILDING | | | OFFICIAL MAY REQUIRE DETAILS, | | | COMPUTATIONS, STRESS DIAGRAMS, AND OTHER | | | DATA NECESSARY TO DESCRIBE THE | | | CONSTRUCTION OR INSTALLATION AND THE | | | BASIS OF CALCULATION. ALL DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | REQUIRED BY THE BUILDING OFFICIAL TO BE | | | PREPARED BY AN ARCHITECT OR ENGINEER | | | SHALL BE AFFIXED WITH THIER OFFICIAL | | | SEAL, SIGNATURE AND DATE AS STATE LAW | | | REQUIRES. | | | | | | 3A) 104.4.5. SPECIAL FOUNDATION PERMIT | | | WHEN APPLICATION FOR A PERMIT TO ERECT | | | OR ENLARGE A BUILDING HAS BEEN FILED, & | | | PENDING ISSURANCE OF SUCH PERMIT, THE | | | BUILDING OFFICIAL MAY, AT HIS/ HER | | | DISCRETION, ISSUE A SPECIAL PERMIT FOR | | | THE FOUNDATION ONLY, UPON WRITTEN RE- | | | QUEST OF THE OWNER AND CONTRACTOR. THE | | | HOLDER OF SUCH A SPECIAL PERMIT IS PRO- | | | CEEDING AT HIS OR HER OWN RISK AND WITH- | | | OUT ASSURANCE THAT A PERMIT FOR THE | | | REMAINDER OF THE WORK WILL BE GRANTED | | | AND THAT CORRECTIONS WILL NOT BE RE- | | | QUIRED IN ORDER TO MEET THE PROVISIONS | | | OF THE TECHNICAL CODE. | | | 3B) WHEN A FOUNDATION PERMIT IS APPLIED | | | FOR IT IS UNDERSTOOD THAT INCLUDES FLOOR | | | SLABS REQUIRING MEP PLANS. IF LOOKING | | | FOR A PERMIT TO START WORK WITHOUT THE | | | REQUIRED MEP SHEETS INDICATE WHAT WORK | | | WILL BE COMPLETED UNDER THIS PERMIT. | | | THE PERMIT APPLICATION BOX DESCRIPTION | | | OF PROJECT SHOULD INCLUDE WHAT TYPE OF | | | WORK IS TO BE COMPLETED UNDER THIS | | | FOUNDATION PERMIT. | | | | | | 4)FL S. S. 553.71(7) " THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS | | | GREATER THAN (3) STORIES OR 50 FT IN | | | HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN | | | CY CLASSIFICATION AS DEINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS | | | 5,000 SQ FT IN AREA AND AN OCCUPANT | | | CONTENT OF GREATER THAN 500 PERSONS. | | | 105.13.1 THE ENFORCING AGENCY SHALL | | | REQUIRE A SPECIAL INSPECTOR TO PERFORM | | | SRUCTURAL INSPECTIONS ON A THRESHOLD | | | BUILDING PURSUANT TO A STRUCTURAL INSPEC | | | TION PLAN PREPARED BY THE ENGINEER OF | | | RECORD. THE STRUCTURAL INSPECTION PLAN | | | MUST BE SUBMITTED TO THE ENFORCING AGEN- | | | CY PRIOR TO THE ISSUANCE OF A BUILDING | | | PERMIT FOR THE CONSTRUCTION OF A THRESH- | | | OLD BUILDING. THE PURPOSE OF THE SRUCTUR | | | AL INSPECTION PLAN IS TO PROVIDE SPECIF- | | | IC INSPECTION PROCEDURES AND SCHEDULES | | | SO THAT THE BUILDING CAN BE ADEQUATELY | | | INSPECTED FOR COMPLIANCE WITH THE | | | PERMITTED DOCUMENTS. | | | | | | 5) WPB AMENDMENT 105.13.6. W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT | | | REQUEST FOR THRESHOLD BUILDINGS A | | | SPECIAL INSPECTOR AS REQUIRED BY S. | | | 553.79(5) FLORIDA STATUTES TO THE MIN- | | | IMUM INSPECTIONS REQUIRED BY THIS CODE. | | | CONTACT HAROLD PISKURA MANAGER OF THE | | | SPECIAL INSPECTOR PROGRAM AT (561) | | | 805-6711 FOR FURTHER INFORMATION BEFORE | | | THE PERMIT MAY BE ISSUED. | | | | | | 6) W.P.B. AMENDMENT 105.13.4.4 ALL PLANS | | | FOR THE BUILDING WHICH ARE REQUIRED TO | | | BE SIGNED AND SEALED BY THE ARCHITECT OR | | | ENGINEER OF RECORD CON- TAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S PR | | | ENGINEER'S KNOWLEDGE, THE PLANS AND | | | SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS | | | DETERMINED BY THE LOCAL AUTHORITY IN | | | ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | 7)106.1.2 ADDITIONAL DATA. THE | | | BUILDING OFFICIAL MAY REQUIRE DETAILS, | | | COMPUTATIONS, STRESS DIAGRAMS, AND OTHER | | | DATA NECESSARY TO DESCRIBE THE | | | CONSTRUCTION OR INSTALLATION AND THE | | | BASIS OF CALCULATION. ALL DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | REQUIRED BY THE BUILDING OFFICIAL TO BE | | | PREPARED BY AN ARCHITECT OR ENGINEER | | | SHALL BE AFFIXED WITH THIER OFFICIAL | | | SEAL, SIGNATURE AND DATE AS STATE LAW | | | REQUIRES. | | | THE STRUCTURAL PLANS START WITH | | | SHEET S-1.0 BUT THE STRUCTURAL NOTES | | | START WITH NUMBER (4). | | | THERE IS NO MENTION OF SOILS | | | REQUIREMENTS, SOILS REPORTS, | | | DENSEIFICATION, NOR AUGER PILE GRADE | | | BEAMS, ETC?S1.1 SOIL NOTE SOIL TO BE | | | DENSIFIED TO 8,000 BY VIBROFLOTATION, | | | PROVIDE REPORT. | | | | | | 8) SEE SHEET S-1.0 FOR IMPORTANCE | | | FACTOR, ASCE 7-98 TABLE 1-1/ TABLE 6-1, | | | BUILDINGS AND OTHER STRUCTURES WHERE | | | MORE THAN 300 PEOPLE CONGREGATE IN ONE | | | AREA WILL REQUIRE THE BUILDING CATEGORY | | | BE A III AND THE IMPORTANCE FACTOR OF | | | 1.15. SEE POOL DECK AND WALKWAYS OF | | | 11,697 SQ FT / 30= 390 OCCUPANT LOAD. | | | | | | 9) SHEET S1.1 FOOTING# 440140 NOT ON | | | FOOTING SCHEDULE.STEEL? | | | | | | 10) SHEET S1.1 FOOTING 200160 NOT ON | | | FOOTING SCHEDULE. STEEL? THERE ARE | | | NUMEROUS FOOTERS THAT ARE NOT ON THE | | | SCHEDULE AND WILL REQUIRE STEEL PLEASE | | | PROVIDE INFORMATION. | | | | | | 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PERMIT: | | | 12) 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY | | | THIS CODE SHALL BE PERMORMED IN A MANNER | | | SO AS NOT TO ADVERSLY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS | | | SUCH ACTIVITY IS PERMITTED TO AFFECT | | | SAID PROPERTY PURSUANT TO A CONSENT BY | | | THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE | | | APPLICABLE PROPERTY OWNER.THIS INCLUDES | | | BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, | | | DEBRIS, AND THE STORAGE OF CONSTRUCTION | | | MATERIALS. NEW CONSTRUCTION ACTIVITY | | | SHALL NOT ADVERSELY IMPACT | | | HISTORICSURFACE WATER DRAINAGE FLOWS | | | SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGNCOMPLYING | | | WITH ENGINEERING STANDARDS TO PRESERVE | | | THE POSITIVE PATTERNS OF THE AFFECTED | | | SITES.ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW | | | RESIDENTIAL DEVELOPMENET, INCLUDING | | | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, | | | DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN | | | EXCESS OF 800SQ FT OF PERMEABLE LAND | | | AREA ON ANY PARCELL SHALL AS A PERMIT | | | CONDITION, PROVIDE A PROFESSIONALY | | | PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 13) 109.3.10.1 HURICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENET AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM | | | HIGHWINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | 14)W P B ADMINISTRTIVE CODE 106.3.3* | | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 15) A0.2 BUILDING DATA PLANS INDICATE | | | ONLY A TYPE I BUILDING NOT GIVEN IF | | | DESIGNED AS A TYPE IA OR IB.TABLE 601 | | | PROVIDE INFO TABLE 601. | | | | | | 16) 110.2* W. P. B. ADMINISTRATIVE CODE, | | | INFORMATION THAT IS REQUIRED FOR RECORD | | | KEEPING & FOR CERTIFICATE OF OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | | | | 17) A0.2 BUILDING DATA THE WRONG CODE | | | FOR ACCESSIBILITY, 2004 FBC CHAPTER 11 | | | | | | 18) A0.2 PARKING CALCULATIONS INDICATE | | | (9) HANDICAPPED PARKING SPACES, INDICATE | | | COMPLIANCE WITH 11-4.1.2(5)(B) | | | IN PARKING STRUCTURES, ONE IN EVERY | | | EIGHTACCESSIBLE SPACES, BUT NOT LESS | | | THAN ONE, SHALL BE "VAN ACCESSIBLE" | | | AND SHALL BE DESIGNED AS REQUIRED BY | | | 11-4.6.3.THE VERTICAL CLEARANCE AT | | | SUCH SPACES SHALL COMPLY WITH 11-4.6.5. | | | ALL SUCH SPACES MAY BE GROUPED ON ONE | | | LEVEL OF A PARKING STRUCTURE.WHEN SUCH | | | SPACES ARE PROVIDED IN A PARKING | | | STRUCTURE AND ONLY ONE IN EIGHT MEET | | | THE HEIGHT REQUIREMENT OF 11-4.6.5, THEY | | | SHALL BE DESIGNATED AS REQUIRED BY | | | 11-4.6.4. | | | | | | 19) A0.2 PARKING CALCULATION INDICATES | | | COMPLIANCE WITH 11-4.1.2 WITH 8 H.C. | | | SPACES SEE TABLE 401-500 SPACES REQUIRES | | | 9 H.C. SPACES, PLEASE CORRECT. | | | | | | 20) LIFE SAFETY PLANS DOES NOT INDICATE | | | THE OCCUPANT LOAD PER FLOOR AND HOW THIS | | | OCCUPANT LOAD IS DISTRIBUTED THROUGH | | | DOORWAYS NOR THROUGH STAIRWAYS TO THE | | | EXIT DISCHARGE.PLEASE ILLUSTRATE. | | | 106.1.2 ADDITIONAL DATA. THE | | | BUILDING OFFICIAL MAY REQUIRE DETAILS, | | | COMPUTATIONS, STRESS DIAGRAMS, AND OTHER | | | DATA NECESSARY TO DESCRIBE THE | | | CONSTRUCTION OR INSTALLATION AND THE | | | BASIS OF CALCULATION. ALL DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | REQUIRED BY THE BUILDING OFFICIAL TO BE | | | PREPARED BY AN ARCHITECT OR ENGINEER | | | SHALL BE AFFIXED WITH THIER OFFICIAL | | | SEAL, SIGNATURE AND DATE AS STATE LAW | | | REQUIRES. | | | | | | | | | 21) A0.4 MEZZANINE LEVEL PROVIE THE | | | SQUARE FOOT OF EACH COMMERCIAL TEANANT | | | FOR THE FIRST FLOOR LEVEL AS WELL AS THE | | | | | | MEZZANINE LEVEL. 505.2 AREA LIMITATION. | | | THE AGGREGATE AREA OF A MEZZANINE OR | | | MEZZANINES WITHIN A ROOM SHALL NOT | | | EXCEED ONE-THIRD OF THE AREA OF THAT | | | ROOM OR SPACE IN WHICH THEY ARE LOCATED. | | | THE ENCLOSED PORTIONS OF ROOMS SHALL NOT | | | BE INCLUDED IN A DETERMINATION OF THE | | | SIZE OF THE ROOM IN WHICH THE MEZZANINE | | | IS LOCATED. IN DETERMINING THE ALLOWABLE | | | MEZZANINE AREA, THE AREA OF THE | | | MEZZANINE SHALL NOT BE INCLUDED IN THE | | | AREA OF THE ROOM. | | | | | | 22)SHEET A1.0/ A1.1 | | | A) DOOR# 14 PLEASE SEE NOTE ON PLANS ALL | | | COMMON AREA DOORS 45 MIN RATED BUT ON | | | THE DOOR SCHEDULE ONLY THE 1 1/2 HR | | | RATED DOORS SHOW ON SCHEDULE. THE DOOR | | | SCHEDULE WILL NEED TO SHOW ALL DOOR | | | RATINGS. | | | | | | B)DOOR 14 AND 36 BOTH ARE OVERHEAD DOORS | | | ON THE REFUSE ROOM. 707.1.13.4 REQUIRES | | | THESE OVERHEAD DOOR TO BE 3/4 RATED & | | | THERE ENCLOSURE, SHOW COMPLIANCE. THE | | | SECOND ISSUE IS THESE UNITS ARE TO BE | | | EITHER SELF CLOSING OR AUTOMATICALLY TO | | | CLOSE IF SMOKE IS DETECTED. | | | | | | 23) A1.2 | | | A)DOORWAY# 7 HALLWAY DOOR TO OFFICE# 004 | | | IS MISSING THE 18" CLEARENCE ON THE PULL | | | SIDE OF LATCHING DEVISE. | | | 11-4.13.6 MANEUVERING CLEARENCES | | | AT DOORS. MINIMUM MANEUVERING CLEARENCES | | | AT DOORS THAT ARE NOT AUTOMATIC OR | | | POWER-ASSISTED SHALL BE AS SHOWN IN | | | FIG. 25. THE FLOOR OR GROUND AREA WITH | | | IN THE REQUIRED CLEARENCES SHALL BE | | | CLEAR & LEVEL. | | | | | | B) PROVIDE INFORMATION ON THE H.C. LIFT? | | | 11-4.11.2IF PLATFORM LIFTS (WHEELCHAIR | | | LIFTS) AREUSED, THEY SHALL COMPLY WITH | | | 11-4.2.4, 11-4.5, 11-4.27, AND ASME | | | A17.1 SAFETY CODE FOR ELEVATORS AND | | | ESCALATORS, SECTION XX, 1990. | | | | | | C) EXTERIOR STAIRS @ DOOR# 35 MISSING | | | THE MAEUVERING CLEARENCES ON THE PULL | | | SIDE OF LATCH, 11-4.13.6 | | | | | | D) DOOR # 30 MISSING THE 18" REQUIRED ON | | | THE LATCH SIDE OF THE DOOR, PULL SIDE. | | | 11-4.13.6. | | | | | | E) THE ELECTRICAL PLAN AND ARCHITECTURAL | | | FOR THIS PORTION OF THE BUILDING DOESN'T | | | | | | MATCH DOOR LOCATIONS SOME ARE MISSING OR | | | PLACED IN VARIOUS AREAS DEPENDING ON THE | | | PLAN THE SAME ISSUE WITH STAIRS. | | | 106.1.2 ADDITIONAL DATA. THE BUILDING | | | OFFICIAL MAY REQUIRE DETAILS, | | | COMPUTATIONS, STRESS DIAGRAMS, AND OTHER | | | DATA NECESSARY TO DESCRIBE THE | | | CONSTRUCTION OR INSTALLATION AND THE | | | BASIS OF CALCULATION. ALL DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA | | | REQUIRED BY THE BUILDING OFFICIAL TO BE | | | PREPARED BY AN ARCHITECT OR ENGINEER | | | SHALL BE AFFIXED WITH THIER OFFICIAL | | | SEAL, SIGNATURE AND DATE AS STATE LAW | | | REQUIRES. | | | | | | F) ROOM 024 IS LABELED THE EMERGENCY | | | ROOM, ELECTRICAL PLANS INDICATE LARGE | | | WALL VENTS WHEREAS THE BUILDING A SOLID | | | WALL, CORRECT. | | | | | | 24) A1.3: ELEVATOR# 3 PROVIDE A CROSS | | | SECTION OF WALL ACROSS FROM ELEVATOR, IS | | | THIS WALL A GLASS WALL OR IS IT ONLY A | | | HANDRAIL? THE PLANS APPEAR TO BE A TRUE | | | MEZZANINE WHICH WILL NOT REQUIRE ATRIUM | | | REQUIREMENTS. SEE ATRIUM REQUIREMENTS IF | | | APPLICABLE, SEE 404.5. | | | | | | 25) A.14: ROOM 040 PROVIDE THE OCCUPANCY | | | CLASSIFICATION ON PLAN S-1 MODERATE | | | HAZARD.PROVIDE WALL AND DOOR RATINGS, | | | OPEMNING PROTECTIVES. TABLE 705.4, | | | TABLE 715.3. ROOM 040 IS NOT AN | | | ANCILLARY TO THE PARKING GARAGE. | | | | | | 26)A1.5: ELEVATOR# 1&2/ MEZZANINE LEVEL. | | | SAME SITUATION AS QUESTION# 23. | | | | | | 27) A1.6/ A1.8 THIS SITUATION DEALS WITH | | | THE 2ND FLOOR THROUGH TO & INCLUDING THE | | | TOP FLOOR. | | | A) ELEVATORS 1/2 & 3/4 TO COMPLY WITH: | | | 707.14.1 ELEVATOR LOBBY. | | | ELEVATORS OPENING INTO A | | | FIRE-RESISTANCE-RATED CORRIDOR AS | | | REQUIRED BY SECTION 1016.1 (R2> 10 OCC | | | LOAD REQUIRES 1HR RATED CORRIDORS) | | | SHALL BE PROVIDED WITH AN ELEVATOR LOBBY | | | AT EACH FLOOR CONTAINING SUCH A | | | CORRIDOR. THE LOBBY SHALL SEPARATE THE | | | ELEVATORS FROM THE CORRIDOR BY FIRE | | | PARTITIONS AND THE REQUIRED OPENING | | | PROTECTION. ELEVATOR LOBBIES SHALL HAVE | | | AT LEAST ONE MEANS OF EGRESS COMPLYING | | | WITH CHAPTER 10 AND OTHER PROVISIONS | | | WITHIN THIS CODE. | | | | | | B) PLANS INDICATE STORAGE UNITS, WHEN | | | YOU GO TO THE 1/4" SCALE PLAN 2.4 THE | | | PLANS STILL DO NOT PROVIDE WALL SECTIONS | | | AS TO TYPE OF CONSTRUCTION AS FOUND ON | | | A2.37. PLANS ARE INCOMPLETE AS TO WALL | | | TYPES FOR MOST OF THE FLOORS.CORRECT. | | | S1 STORAGE REQUIRES A 3HR WALL AND | | | OPENING PROTECTIVES. SEE FIRE BARRIER | | | T 715.3 | | | | | | 28) A1.21: | | | A) THE EAST SIDE OF THE COVERED VARANDA | | | & HEALTH CLUB DOES NOT HAVE ANY | | | DIMENSION AS TO THE PROPERTY LINE, & | | | PLANS DO NOT PROVIDE IF TYPE IA OR IB, | | | WHICH WILL MAKE A DIFFERENCE IN | | | ALLOWABLE OPENINGS | | | | | | B) RAMP TO SPA, | | | 11-4.8.2 SLOPE & RISE. THE LEAST | | | POSSIBLE SLOPE SHALL BE USED FOR ANY | | | RAMP. THE MAXIMUM SLOPE FOR A RAMP IN | | | NEW CONSTRUCTION SHALL BE 1 TO 12. THE | | | MAXIMUM RISE FOR RUN SHALL BE 30" (SEE | | | FIGURE 16). | | | 11-4.8.4(3) IF RAMPS CHANGE DIREC- | | | TION AT LANDINGS, THE MINIMUM LANDING | | | SIZE SHALL BE 60" X 60". | | | 11-4.8.4.(2) LANDINGS. ALL LANDINGS | | | ON RAMPS SHALL NOT BE LESS THAN 60" | | | CLEAR, & THE BOTTOM OF EACH RAMP SHALL | | | HAVE NOT LESS THAN 72" OF STRAIGHT & | | | LEVEL CLEARENCE. | | | 11.4.8.5. HANDRAILS: IF A RAMP HAS | | | A RISE GREATER THAN 6" OR A HORIZONTAL | | | PROJECTION GREATER THAN 72", THEN IT | | | SHALL HAVE HANDRAILS ON BOTH SIDES. | | | | | | C) THE PLANS SHOW THE ELEVATION AT 0'-0" | | | WITH NO CHANGE IN GRADE TO THE INTERIOR? | | | | | | D) PLANS INDICATE USE OF METAL TRUSSES | | | ON THE HEALTH CLUB BUT NO MENTION OF | | | TYPE OF DECKING ? SEE TABLE 601 FOR 1 | | | 1/2 HR RATING. | | | | | | E) PLANS INDICATE FLOOR OR ROOF DRAINS | | | SEE SECTION A8.7 DETAIL E, THIS DETAIL | | | INDICATES SEE SEE MECH DRAWINGS? WHERE? | | | THE PLUMBING SHEET 21.9 ALSO INDICATES | | | FLOOR DRAINS BUT NO SECTION THROUGH THE | | | SLAB INDICATING COMPLIANCE WITH 712.4.1 | | | THROUGH PENETRATIONS OF HORIZONTAL | | | ASSEMBLIES. | | | 712.4.1.1PENETRATIONS SHALL BE | | | INSTALLED AS TESTED IN AN APPROVED FIRE | | | RESISTANCE-RATED ASSEMBLY. PROVIDE | | | ADDITIONAL INFORMATION. | | | | | | 29) A3.0 | | | A) THE DOOR SCHEDULE INDICATES (2) TYPES | | | OF RATED DOORS #14 & #15. THE DETAILS ON | | | THIS PAGE INDICATE FRAMES AND SILLS BUT | | | NO MENTION TO DOORS 14 OR 15. | | | | | | 708.6 OPENINGS IN FIRE PARTITIONS SHALL | | | BE PROTECTEDIN ACCORDANCE WITH SECTION | | | 715.. 715.3.3 FIRE DOOR ASEMBLIES SHALL | | | ALSO MEET THE REQUIREMENTS FOR A SMOKE | | | AND DRAFT CONTROL DOOR ASSEMBLIES TESTED | | | IN ACCORDANCE WITH UL 1784 WITH AN | | | ARTIFICIAL BOTTOM SEAL INSTALLED ACROSS | | | THE FULL WIDTH OF THE BOTTOM OF THE DOOR | | | ASSEMBLY. | | | | | | 710.5.2 SMOKE AND DRAFT CONTROL DOORS, | | | DOORS IN SMOKE PARTITIONS SHALL BE | | | TESTED IN ACCORDANCE WITH UL 1784 WITH | | | AN ARTIFICIAL BOTTOM SEAL INSTALLED | | | ACROSS THE FULL WIDTH OF THE BOTTOM OF | | | THE DOOR ASSEMBLY. | | | | | | 30) A1.31: | | | A) PLANS INDICATE USSE OF METAL | | | TRUSSES BUT NO MENTION AS TO THE TYPE OF | | | DECKING MATERIAL? TABLE 601 1 1/2 HR | | | RATING. | | | | | | B) PLANS INDICATE A STORAGE OCCUPANCY ON | | | THE ROOF? WHAT TYPE OF MATERIALS WILL BE | | | STORED THERE, S1 VS S2? | | | | | | 31) PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 32)W P B ADMINISTRTIVE CODE 106.3.3* | | | PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 33) FL BLD CODE 1606.1.5: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- | | | OLD OR RESIDENT INSPECTOR) OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS | | | FOLLOWS: | | | A) EXTERIOR WINDOWS FIXED | | | B) EXTERIOR WINDOWS OPERATABLE | | | C) MULLIONS | | | D) EXTERIOR GLAZED DOORS | | | E) EXTERIOR ROLL UP DOORS | | | F) LOUVERS | | | G) TRUSS ANCHOR ATTACHMENTS | | | H) STORM SHUTTERS | | | I) EFIS SYSTEMS | | | J) EXTERIOR RAILINGS | | | K) ROOFING ASSEMBLIES FLAT AND SLOPED | | | ALL OF THE ABOVE MENTIONED PRODUCTS | | | WILL REQUIRE THE DESIGNER OF RECORD TO | | | SIGN OFF THAT THE REPORTS HAVE BEEN | | | REVIEWEDAND APROVED BY THEIR OFFICE. | | | | | | 34)A3.2 | | | A) WHY DOES THE WINDOW TYPES INDICATE | | | TOWNHOUSES? | | | B) NOTE # 7 INDICATES THAT THE WINDOWS | | | AND DOORS ARE GOING TO BE UNDER SEPERATE | | | PERMIT. THIS MEANS THIS BUILDING IS | | | ACTUALLY DESIGNED AS OPEN AND NOT | | | CLOSED! THE WINDOW AND DOORS WILL BE | | | REQUIRED TO BE SUBMITTED AND READY FOR | | | PERMIT BEFORE THE BUILDING PERMIT WIL BE | | | LET. | | | | | | 35) A4.0,A4.1, A4.2 & A4.3 | | | A) ALL INDICATE WOOD TRIM BRACKETS SEE | | | 1406.2.2ARCHITECTURAL TRIM THAT | | | EXCEEDS 40 FEET (12 192 MM) IN HEIGHT | | | ABOVE GRADE PLANE SHALL BE CONSTRUCTED | | | OF APPROVED NONCOMBUSTIBLE MATERIALS AND | | | SHALL BE SECURED TO THE WALL WITH METAL | | | OR OTHER APPROVED NONCOMBUSTIBLE | | | BRACKETS. | | | NONCOMBUSTIBLE- MATERIALS WHICH PASS THE | | | TEST PROCEDURE SET FORTH IN ASTM E 136. | | | | | | B)NOTE:STANDING SEAM METAL ROOF ON | | | METAL TRUSSES FOR AWNING TYPE | | | SHADES.PROVIDE ENGINEERING HOW THIS | | | SYSTEM IS TO BE BUILT AND IF THIS SYSTEM | | | IS TO STAY IN THE OPEN POSITION DURING A | | | HIGH WINDEVENT PROVIDE CALCULATIONS. | | | | | | C) INDICATE ON THE ELEVATIONS, PRESSURE | | | ZONES FOR OPENINGS +/- FOR THE INTERIOR | | | AND END ZONES (ZONES 4 & 5). ALSO | | | PROVIDE THE ROOF PRESSURE ZONES FOR | | | ZONES 1,2& 3. | | | | | | D) ELEVATIONS DO NOT PROVIDE WHERE THE | | | PROPERTY LINES ARE LOCATED? | | | | | | 36)A7.4 | | | A) STAIRWELL# 4 INDICATES THE USE OF A | | | MECHANICAL SHAFT BUT NO DESIGNATION AS | | | TO WALL TYPE? 2 HR RATED. | | | | | | B) A7.5 SAME STAIRWELL# 4 INDICATES THE | | | MECHANICAL SHAFT INTRUDING INTO THE | | | STAIRWELL NOT STOPPING AT THE 2ND FLOOR | | | LEVEL.707.4 SHAFT ENCLOSURES SHALL HAVE | | | A FIRE-RESISTANCE RATING NOT LESS THAN | | | THE FLOOR ASSEMBLY PENETRATED, BUT NEED | | | NOT EXCEED 2 HOURS. | | | | | | 37) A7.6/A7.7 ELEVATOR MACHINE ROOMS | | | MISING INFORMATION ON VENTS: | | | A)3004.2 LOCATION OF VENTS. | | | VENTS SHALL BE LOCATED BELOW THE FLOOR | | | OR FLOORS AT THE TOP OF THE HOISTWAY, | | | AND SHALL OPEN EITHER DIRECTLY TO THE | | | OUTER AIR OR THROUGH NONCOMBUSTIBLE | | | DUCTS TO THE OUTER AIR. NONCOMBUSTIBLE | | | DUCTS SHALL BE PERMITTED TO PASS THROUGH | | | THE ELEVATOR MACHINE ROOM PROVIDED THAT | | | PORTIONS OF THE DUCTS LOCATED OUTSIDE | | | THE HOISTWAY OR MACHINE ROOM ARE | | | ENCLOSED BY CONSTRUCTION HAVING NOT LESS | | | THAN THE FIRE PROTECTION RATING REQUIRED | | | FOR THE HOISTWAY. HOLES IN THE MACHINE | | | ROOM FLOORS FOR THE PASSAGE OF ROPES, | | | CABLES OR OTHER MOVING ELEVATOR | | | EQUIPMENT SHALL BE LIMITED SO AS NOT TO | | | PROVIDE GREATER THAN 2 INCHES (51 MM) OF | | | CLEARANCE ON ALL SIDES. | | | | | | B) 3004.3 AREA OF VENTS. | | | EXCEPT AS PROVIDED FOR IN SECTION | | | 3004.3.1 , THE AREA OF THE VENTS SHALL | | | NOT BE LESS THAN 3? PERCENT OF THE AREA | | | OF THE HOISTWAY NOR LESS THAN 3 SQUARE | | | FEET (0.28 M 2 ) FOR EACH ELEVATOR CAR, | | | AND NOT LESS THAN 3? PERCENT NOR LESS | | | THAN 0.5 SQUARE FOOT (0.047 M 2 ) FOR | | | EACH DUMBWAITER CAR IN THE HOISTWAY, | | | WHICHEVER IS GREATER. OF THE TOTAL | | | REQUIRED VENT AREA, NOT LESS THAN | | | ONE-THIRD SHALL BE OF THE PERMANENTLY | | | OPEN TYPE UNLESS ALL VENTS ACTIVATE UPON | | | DETECTION OF SMOKE FROM ANY OF THE | | | ELEVATOR LOBBY SMOKE DETECTORS. | | | | | | 38) A7.8 & A7.9 INDICATE USE OF 6" BLOCK | | | FOR 2 HR WALL RATING. A U.L. LISTING OF | | | WHAT TYPE OF BLOCK IS NOT PROVIDING THE | | | FIRE RESISTANT RATING BASED ON | | | EQUIVALENT THICKNESS OF THE MASONARY | | | UNIT AND TYPE OF AGGREGATE USED. THIS | | | SHALL BE PROVIDED BY THE BLOCK | | | MANUFACTURER. | | | | | | 39) A.80 DETAIL# 25 IS A SHAFT WALL | | | PARTITION DESIGN UL U-415. THIS DESIGN | | | IS MISSING THE REQUIRED C-H STUDS IN THE | | | DESIGN. CORRECT.SAME DETAIL SHOWN ON | | | LS.0 CORRECT. | | | | | | 40) A8.1 DETAIL"N" IS FOR A ROLL DOWN | | | FIRE RATED DOOR WITHIN A RATED WALL. | | | PROVIDE THE UL RATING FOR THE WAY THE | | | ROLL DOWN ASSEMBLY BOX TAKES THE PLACE | | | OF THE RATED WALL? | | | | | | 41) A8.3 DETAIL H APPEARS THIS DETAIL IS | | | MISSING THE VERTICAL BARS AT THE BOTTOM | | | OF THE DETAIL THAT WILL KEEP THE 4" | | | SPHERE FROM PASSING THROUGH. 1012.3 | | | OPENING LIMITATION. | | | | | | 42) S-1.0 AS STATED UNDER FOUNDATION | | | PERMIT NOTES START WITH NOTE# 4 FOR | | | CONCRETE. | | | | | | A) NOTE A REFRENCES ACI 301-99 | | | STRUCTURAL CONCRETE,1901.2/1901.3 | | | CORRECT TO ACI 318-02. | | | | | | B) MISSING WIND DESIGN: | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO | | | WIND LOADS SHALL BE SHOWN, REGARDLESS OF | | | WHETHER WIND LOADS GOVERN THE DESIGN OF | | | THE LATERAL-FORCE-RESISTING SYSTEM OF | | | THE BUILDING: | | | 1.BASIC WIND SPEED (3-SECOND GUST), | | | MILES PER HOUR (KM/HR). | | | 2.WIND IMPORTANCE FACTOR, I W , AND | | | BUILDING CLASSIFICATION FROM TABLE | | | 1604.5 OR TABLE 6-1, ASCE 7 AND BUILDING | | | CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | 3.WIND EXPOSURE, IF MORE THAN ONE | | | WIND EXPOSURE IS UTILIZED, THE WIND | | | EXPOSURE AND APPLICABLE WIND DIRECTION | | | SHALL BE INDICATED. | | | 4.THE APPLICABLE ENCLOSURE | | | CLASSIFICATIONS AND, IF DESIGNING WITH | | | ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | 5.COMPONENTS AND CLADDING. THE | | | DESIGN WIND PRESSURES IN TERMS OF PSF | | | (KN/M 2 ) TO BE USED FOR THE DESIGN OF | | | EXTERIOR COMPONENT AND CLADDING | | | MATERIALS NOT SPECIFICALLY DESIGNED BY | | | THE REGISTERED DESIGN PROFESSIONAL. | | | | | | 43) S1-3.4- S1-3.6 TRUSS DIAGRAMS | | | MISSING THE MAGNITUDE OF LOADS TO BE | | | REISTED, UPLIFT, HORIZONTAL AND GRAVITY | | | LOADS. | | | | | | 44) S-4.1 SAME COMMENT 9 & 10 FOUNDATION | | | SCHEDULE NOT COMPLETE. | | | | | | 45) S-8.1-S-8.3 ELEVATIONS WITH | | | PRESSURES ZONES ARE SO SMALL THE NUMBERS | | | BECOME SMUGED AND ILLEGIBLE. | | | | | | 46) PROVIDE ENERGY CALCS FOR BUILDING: | | | 13-400.1 PRESCRIPTIVE REQUIREMENTS. | | | WHERE A PRESCRIPTIVE REQUIREMENT | | | SPECIFIC TO A METHOD IS MORE STRINGENT | | | THAN THE BASIC PRESCRIPTIVE REQUIREMENT, | | | THE MORE RESTRICTIVE REQUIREMENT SHALL | | | BE MET. | | | | | | 47) PLANS ARE CURRENTLY IN FOR PLAN | | | REVIEW, BUT WHEN PLANS ARE SUBMITTED TO | | | THE BUILDING DEPARTMENT FOR PERMIT | | | APPLICATION: | | | PLANS, SPECIFICATIONS,REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER | | | TEL: (561)805-6715 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
27 |
Status |
P |
Date |
2008-12-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-12-09 |
Time |
08:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-12-09 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2008-12-09 08:29:14 | | | | ** REVIEW OF REVISIONS ** | | | | | | *** THE SUBMITTED PLANS ARE IN FACT NOT RE-STAMPS. MANY | | | OF THE SHEETS ARE IN FACT REVISIONS OF PLANS ALREADY ON | | | FILE. | | | IN THE ROLL OF PLANS SUBMITTED 37 SUBMITTED SHEETS ARE | | | RE-STAMPS AND 33 ARE REVISIONS. THIS DOES NOT INCLUDE | | | THE REVIEW OF THE FIRE ALARM SHEETS. IT IS NOT KNOWN | | | WHETHER OR NOT THEY ARE REVISIONS, RE-STAMPS OR BOTH. | | | THE FEE BALANCE DUE FOR THE REVISED SHEETS IS $230.00. | | | THE FOLLOWING IS A LIST OF THE RE-STAMPED SHEETS AND A | | | LIST OF THE REVISED SHEETS. | | | NOT ALL SHEETS OF THE ON FILE SET WAS SUBMITTED FOR | | | RE-STAMP OR REVISIONS. AN EXAMPLE IS SHEET 8.05 WHICH | | | WAS NOT IN SETS FOR EITHER. | | | | | | **RE-STAMPS** | | | E-1.01,2.01A,2.02,2.02A,2.03,2.03A,2.04,2.05,2.07,2.08, | | | 2.10,2.11,2.13,2.15,2.16,2.18,2.19,2.20,2.23,2.29,2.30, | | | 2.31,2.32,2.33,3.01,3.02,3.03,3.04,3.05,3.06,5.01,5.02, | | | 6.01,6.02,8.06,8.07A, 8.07B. | | | | | | | | | ** REVISED | | | E- | | | 0.01,1.01A, 2.01,2.06,2.09,2.12,2.14,2.17,2.20A,2.21,2. | | | 22,2.24,2.25,2.26,2.27,2.28,2.34,2.35,2.36,4.01,5.03,7. | | | 01,8.01,8.02,,8.03,8.04,8.05A,8.05B,8.08,8.09,8.10,8.11 | | | | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
26 |
Status |
F |
Date |
2008-10-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-10-30 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-10-30 |
Time |
14:28 |
Sent To |
PC |
|
| Notes |
| 2008-10-30 14:28:24 | ** DENIED REVIEW** | | | | | | 1) NOTE: PLANS SUBMITTED FOR *RE-STAMP* ARE NOT IN FACT | | | RE-STAMPS BASED ON OUR FILE SET OF LATEST ELECTRICAL | | | PLANS. PLEASE SUBMIT THREE SETS OF ALL REVISED SHEETS. | | | THE FOLLOWING SHEETS NOTED BELOW ARE ONLY SOME EXAMPLES | | | OF SHEETS WHICH ARE REVISED HOWEVER ARE NOT IN OUR | | | RECORD SET OF ELECTRICAL PLANS. | | | | | | E.0.01, LAST REVISED ON FILE IS REV #18 | | | E.1.01A LAST REVISED ON FILE IS REV #10 | | | E2.01 LAST REVISED ON FILE IS REV #17 | | | E2.05 LAST REVISED ON FILE IS REV #16 | | | E2.06 LAST REVISED ON FILE IS REV #16 | | | E2.09 LAST REVISED ON FILE IS REV #5 | | | | | | ** THE PLANS SUBMITTED WILL BE CHARGED FEES BASED ON | | | REVISIONS. THE PLANS SUBMITTED WILL HAVE A $60 ADDED TO | | | THIS ROLL AS THEY WERE NOT RE-STAMPS. BALANCE TO BE | | | PAID WHEN RESUBMITTING FOR REVISIONS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
25 |
Status |
P |
Date |
2008-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-24 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-24 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2008-09-24 10:56:41 | SELECTIVE COORDINATION STUDY OK. DOES NOT MATCH PLANS. | | | WILL NEED REVISED PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
24 |
Status |
F |
Date |
2008-09-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-16 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-16 |
Time |
14:43 |
Sent To |
PC |
|
| Notes |
| 2008-09-16 14:44:00 | | | | ** DENIED REVIEW OF SELECTIVE COORDINATION STUDY** | | | | | | 1) NOTE: PLEASE SEE THERE ARE MANY ITEMS ON THE SCS | | | WHICH DO NOT COORDINATE WITH THE PLANS ON FILE. PLEASE | | | SEE 240.12,700.27 AND 701.18. | | | THE FOLLOWING WILL BE SOME EXAMPLES ONLY AND ARE IN NO | | | WAY ALL ITEMS ON THE REPORT WHICH DOES NOT MATCH WITH | | | PLANS. | | | | | | A) PLEASE SEE SECTION #5 OF THE REPORT AND OTHER | | | SECTIONS WHICH DO NOT SEEM TO INDICATE THE EDPH PANEL | | | AS CONTAINING A MAIN CIRCUIT BREAKER. PLANS SHOW A 100K | | | RATED MCB. | | | | | | B) PLEASE SEE THE HEC PANEL LISTED IN SECTION #5 ON | | | EDPH WHICH SHOWS A 300AMP BREAKER YET THE PLANS ON FILE | | | INDICATE A 150AMP BREAKER. THE PANEL HEC IS NOT EVEN | | | RATED FOR 300AMPS. | | | | | | C) PLEASE SEE DAPPER FAULT ANALYSIS INPUT REPORT. | | | SWB MSBE SHOWS COPPER BUS DUCT STAB. PLEASE VERIFY. | | | PLEASE SEE OTHERS SUCH AS ATS/MSBE SHOWS COPPER, EDPH | | | COPPER, FIRE PUMP COPPER, ETC ETC | | | PLEASE SEE THE SIZE OF CONDUCTORS FOR ITEMS SUCH AS | | | FIRE PUMP WHICH ARE SHOWN AS 3/0 COPPER YET THE RISER | | | ON FILE SHOWS 250MCM ALUMINUM. | | | PLEASE SEE THE DISTANCE OF FEEDERS FOR THE FIRE PUMP | | | UNDER NORMAL AND EMERGENCY WHICH IS SHOWN AS 500FEET. | | | THIS IS NOT POSSIBLE. | | | PLEASE SEE OTHER PANELS FOR FEEDERS, DISTANCE, WHICH | | | DOES NOT MATCH. | | | GEHB SHOWS 3/0 ON REPORT AND SHOWS 1/0 ON PLANS. THE | | | DISTANCE ON THIS FEEDER ALONE CALLS FOR 75FEET HOWEVER | | | BASED ON THE LOCATION OF THIS PANEL ON THE PLANS THE | | | DISTANCE IS FAR GREATER. | | | HEA, 3/0 ON REPORT, SHOWS 1/0 ON PLANS. | | | HEC SHOWS 3/0 ON REPORT YET SHOWS 1/0 ON PLANS. | | | REHA SHOWS 500 MCM ON REPORT AND 400MCM ON PLANS. | | | REHC SHOWS 500MCM ON REPORT AND 400MCM ON PLANS. | | | | | | **** TO BE NOTED ONCE AGAIN. THESE ARE ONLY SOME | | | EXAMPLES OF THE INCONSISTENCIES AND ARE NOT ALL | | | POSSIBLE COORDINATION ISSUES. | | | ONE COPY OF THE REPORT WILL BE RETAINED BY THIS OFFICE. | | | | | | 2) NOTE: PLEASE KNOW A REVISION FEE OF $60 IS DUE. FBC | | | 108.3 | | | | | | | | | **IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANOR PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
23 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-04 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-04 |
Time |
14:57 |
Sent To |
PC |
|
| Notes |
| 2008-09-04 15:00:38 | REVSIONS. | | | | | | ***REQUIRED BEFORE TCO. | | | NEED COORDINATION STUDY OF EMERGECNY | | | SYSTEMS/PANELS/EQUIPMENT PER 240.12, NFPA-110 6.5 | | | PROTECTION. | | | | | | 6.5.1* GENERAL. THE OVERCURRENT PROTECTIVE DEVICES IN | | | THE EPSS SHALL BE COORDINATED TO OPTIMIZE SELECTIVE | | | TRIPPING OF THE CIRCUIT OVERCURRENT PROTECTIVE DEVICES | | | WHEN A SHORT CIRCUIT OCCURS. | | | | | | 6.5.2 SHORT CIRCUIT CURRENT. THE MAXIMUM AVAILABLE | | | SHORT CIRCUIT CURRENT FROM BOTH THE UTILITY SOURCE AND | | | THE EMERGENCY ENERGY SOURCE SHALL BE EVALUATED FOR | | | ABILITY TO SATISFY THIS COORDINATION CAPABILITY. | | | | | | 6.5.3* OVERCURRENT PROTECTIVE DEVICE RATING. THE | | | OVERCURRENT PROTECTIVE DEVICE SHALL HAVE AN | | | INTERRUPTING RATING EQUAL TO OR GREATER THAN THE | | | MAXIMUM AVAILABLE SHORT CIRCUIT CURRENT AT ITS | | | LOCATION. | | | | | | 6.5.4 ACCESSIBILITY. OVERCURRENT DEVICES IN EPSS | | | CIRCUITS SHALL BE ACCESSIBLE TO AUTHORIZED PERSONS | | | ONLY. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
22 |
Status |
P |
Date |
2008-09-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-09-04 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-09-04 |
Time |
14:56 |
Sent To |
PC |
|
| Notes |
| 2008-09-04 14:57:04 | REV PANEL SCHEDULES ON E6.02 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
21 |
Status |
P |
Date |
2008-07-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-18 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-18 |
Time |
10:42 |
Sent To |
|
|
| Notes |
| 2008-07-18 10:50:57 | REVISIONS OK, REDLINED FBC 11-4.27.4 FOR TIMER DEVICES. | | | SHALL NOT BE DEVICES WHICH REQUIRE TWISTING,/GRASPING | | | ETC. | | | 2.01, 2.02,3.01,3.02, 3.03,3.04,3.05,3.06 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
20 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-16 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-16 |
Time |
14:00 |
Sent To |
PC |
|
| Notes |
| 2008-06-16 14:00:40 | REV 6.02 OK |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
19 |
Status |
F |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-16 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-16 |
Time |
13:59 |
Sent To |
PC |
|
| Notes |
| 2008-06-16 14:00:12 | ** DENIED / PASSED REVISIONS** | | | | | | 1) NOTE: PLEASE SEE FEEDER F-8 IS SHOWN FROM GENERATOR | | | TO FIRE PUMP WITH 250AMP OVER CURRENT PROTECTION. | | | PLEASE SEE 250.122 AS THE EQUIPMENT GROUNDING CONDUCTOR | | | IS REQUIRED TO BE SIZED FOR THE OCP> | | | PLAN SHOWS #6 WHICH IS RATED FOR 200AMPS ONLY. | | | THIS COULD HAVE BEEN REDLINED HOWEVER PLANS ARE FOR | | | FINAL AS-BUILTS. | | | | | | 2) NOTE: REVISED 6.01, 6.02, 6.03 OK, STAMPED. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
18 |
Status |
P |
Date |
2008-05-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-20 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-20 |
Time |
13:52 |
Sent To |
PC |
|
| Notes |
| 2008-05-20 13:53:07 | REV #18, 0.01,2.01A,2.02,2.05, 5.01, 6.01 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
17 |
Status |
F |
Date |
2008-04-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-18 |
Time |
13:35 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-18 |
Time |
13:46 |
Sent To |
PC |
|
| Notes |
| 2008-04-18 13:37:50 | ** DENIEDREVIEW OF REVISIONS ** | | | | | | THE FOLLOWING IS FOR ELECTRICAL REVISIONS SUBMITTED | | | 3/19/08 AND 4/7/08. | | | | | | 1) NOTE: PLEASE COORDINATE ALL REVISIONS ALONG WITH | | | REVISED TITLE BLOCKS AND REVISIONS ON PLANS. | | | FOR EXAMPLE: | | | PLEASE SEE SHEETS E0.01, E5.1 ETC WHICH ARE SIGNED, | | | DATED AND SEALED ABOUT 3WEEKS APART YET THE PLANS ARE | | | THE SAME. THESE SHEETS SHOW THE SAME EXACT REVISIONS. | | | SHEET E0.01 DATED 3/17/08 ARE SHOWING REVISIONS 16 AND | | | 17 AND REVISED SHEET E0.01 DATED 4/3/08 SHOW THE SAME. | | | | | | THIS IS THE SAME FOR SOME OF THE OTHER SHEETS AS WELL. | | | PLEASE GO THOUGH BOTH SETS, REVISE PLANS, TITLE BLOCKS | | | AND SUBMIT COMPLETED SETS FOR REVIEW. | | | ** PLEASE KNOW ANY OTHER REVIEW COMMENTS FOR FEEDERS | | | ETC SHOULD BE INCORPORATED INTO CHANGES. | | | | | | 2) NOTE: PLEASE SEE THIS REVIEWER'S PREVIOUS COMMENT | | | WITH RESPECT TO GROUND FAULT PROTECTION ON MAINS AND | | | OTHER EQUIPMENT WAS THAT THE EDPH WAS NOT TO CONTAIN | | | GFP. NOW THE MSBE HAS THE GROUND FAULT PROTECTION | | | REMOVE WHICH WAS LOCATED ON ORIGINAL PLANS. | | | PLEASE SEE 240.13, 230.95 ETC WHICH DOES REQUIRE GFP ON | | | THE MAIN. THE CODE DOES NOT REQUIRE GFP ON THE | | | EQUIPMENT AFTER THE MAIN IN THIS SITUATION. THERE ARE | | | SOME CIRCUMSTANCES IN THE CODE WHICH DOES REQUIRE GFP | | | ON THE EQUIPMENT AFTER THE MAIN HOWEVER NOT ON THE | | | EMERGENCY SIDE AND NOT IN THIS OCCUPANCY. | | | PLEASE PLACE THE GFP BACK ON MSBE AND PLEASE BE SURE | | | GFP IS NOT ON EDPH. | | | IF THERE ARE ANY QUESTIONS ON THIS PLEASE CONTACT THIS | | | OFFICE. | | | | | | 3) NOTE: PLEASE KNOW THE REVISED ENERGY CALCULATIONS | | | SUBMITTED WERE NOT REVIEWED. THESE ARE CONSIDERED A | | | REVISION AND WOULD BE SUBMITTED ACCORDINGLY. | | | BASED ON THE FACT THAT THERE ARE CHANGES BEING MADE TO | | | PLANS AND PROJECT THE REVISED CALCULATIONS SHOULD ONLY | | | BE SUBMITTED FOR FINAL REVIEW ONCE *ALL* CHANGES TO | | | PROJECT ARE KNOWN AND WILL BE THE FINAL REVISION BEFORE | | | FINAL/CO. | | | PLEASE CALL IF THERE ARE ANY QUESTIONS ON THIS. | | | ** PLEASE ALSO KNOW THAT ANY REVISED ENERGY | | | CALCULATIONS WILL ALSO BE REVIEWED BY MECHANICAL, | | | BUILDING AND POSSIBLY PLUMBING. PLEASE BE SURE ALL | | | PLANS FOR OTHER TRADES HAVE BEEN UPDATE TO THE POINT | | | FOR FINAL REVIEW SO THE PLANS ON FILE WILL COORDINATE | | | WITH CALCULATIONS. | | | | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
16 |
Status |
P |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-17 |
Time |
12:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-15 |
Time |
20:06 |
Sent To |
|
|
| Notes |
| 2008-01-17 12:30:21 | ** PROVISO** | | | | | | 1) NOTE: PLEASE SEE SHEET E206 WHICH STILL HAS LIGHTING | | | CONTROL FOR STORAGE ROOM SHOWN AS MANUAL WHEN AUTOMATED | | | MEANS IS REQUIRED PER FBC 13-415.1.ABC.1.1, .1.2. | | | | | | 2) NOTE: PLEASE SEE GF PROTECTION ON EDPH IS NOT | | | PERMITTED. (REDLINED) | | | | | | 3) NOTE: PLEASE SEE PHOTO-METRICS WERE STILL NOT | | | SUBMITTED AS REQUIRED PER PREVIOUS REVIEWS AND PER LS | | | 101 7.8 AND 7.9. | | | THESE WILL BE REQUIRED. | | | | | | 4) NOTE: PLEASE SEE REVISED ENERGY CALCULATIONS HAVE | | | ALSO NOT BEEN SUBMITTED. THESE ARE REQUIRED DUE TO | | | NUMEROUS CHANGES TO ELECTRICAL LIGHTING FIXTURES. | | | 13-415.1.A, 13-415.2 | | | | | | 5) NOTE: PLEASE SEE THE EQUIPMENT GROUNDING CONDUCTOR | | | ON RISER FROM MSBE TO EDPH STILL DOES NOT CORRELATE | | | WITH THE EQUIPMENT GROUNDING ON MSBE SCHEDULE. 2/0, | | | 3/0. | | | | | | 6) NOTE: PLEASE KNOW THE LOW VOLTAGE PERMIT WHICH WAS | | | FINALLY PULLED FOR CATV AND PHONE SYSTEM WIRING IS NOW | | | ON HOLD FOR INSPECTIONS. THE APPLIED VALUE FOR ALL CATV | | | AND PHONE IN BUILDING IS SHOWN AS $10K. THIS VALUE IS | | | EXTREMELY LOW. THE MATERIALS COST MORE THAN THIS | | | AMOUNT. A COST ANALYSIS CAN BE ASSESSED USING MARSHALS | | | & SWIFT GUIDE AS ADOPTED PER FBC 108.3 IF AN | | | APPROPRIATE VALUE IS NOT ADJUSTED. | | | | | | | | | 7) NOTE: PLEASE BE SURE TO GO BACK THROUGH ALL | | | ELECTRICAL COMMENTS MADE TO DATE. PLEASE SUBMIT REVISED | | | INFORMATION AS NEEDED AND SUBMIT CORRECTIONS AS NEEDED | | | FOR SEVERAL ITEMS WHICH TO DATE HAVE STILL NOT BEEN | | | ADDRESSED. | | | ** PLEASE KNOW THIS WILL HOLD UP TCO AND FINAL | | | INSPECTIONS. IF INFORMATION DOES NOT MEET MINIMUM CODE | | | COMPLIANCE CHANGES IN SCOPE OF WORK AS SHOWN MAY BE | | | REQUIRED. | | | SOME ITEMS AS PREVIOUSLY REQUESTED CAN NOT BE REVIEWED | | | AT THIS TIME AS THEY WERE NOT SUBMITTED. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PAM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
15 |
Status |
F |
Date |
2007-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-22 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-22 |
Time |
15:59 |
Sent To |
PC |
|
| Notes |
| 2007-09-22 18:53:16 | ** DENIED REVISIONS ** | | | | | | | | | ** PLEASE SEE REVISIONS DATED THE SAME DATE OF 9/22/07 | | | WHICH NOTES WERE PROVIDED ON REVISIONS SUBMITTED ON | | | 8/23/07. | | | PLEASE SEE SOME ITEMS BELOW FOR REVISIONS SUBMITTED | | | 9/20/07 NEED TO BE ADDRESSED. | | | | | | 1) NOTE: PLEASE SEE THESE REVISIONS INDICATE A NEW 2500 | | | GALLON CON-VAULT YET NO PLANS OR SUBMITTALS COULD BE | | | FOUND REVISING THESE ITEMS. | | | PLEASE KNOW ANY MANUFACTURES SPECS/CUT SHEETS FOR FUEL | | | TANK WILL BE REQUIRED TO BE REVIEWED BY FIRE AND | | | MECHANICAL REVIEWERS. | | | PLEASE ALSO KNOW REVISED PLANS FOR LOCATION ETC WILL | | | NEED TO BE SUBMITTED. | | | | | | 2) NOTE: THE NEW PLANS INDICATE THE GENERATOR WILL BE | | | OPERATING AT A REDUCED LOAD FOR THE EXTENDED TIMES AS | | | LISTED. THERE ARE SEVERAL ITEMS ON PANELS WHICH | | | INDICATE A REDUCED LOAD HOWEVER NO DETAILS ON HOW THESE | | | LOADS WILL BE SHED FROM THE PANEL(S) OR THE GENERATOR | | | WAS SUBMITTED. | | | HOW WILL LOADS BE TAKEN FROM THE PANELS? | | | HOW WILL FANS, EXHAUST ETC BE SHED AND WILL THESE | | | SYSTEMS FOR VENTILATION STILL BE OPERABLE IN THE EVENT | | | OF LEVELS OF AIR GO INTO HIGH LEVELS ETC. | | | PLEASE PROVIDE MORE INFORMATION ON SYSTEMS, WIRING, | | | DETAILS, SHEDDING OF LOADS DOWN TO THE 255 AS NOTED | | | ETC. | | | FBC 106.1.2 ADMIN SECTION FOR INFORMATION NEEDED. | | | | | | 3) NOTE: PLEASE SEE THE FEEDERS ON FEEDERS SCHEDULE FOR | | | F-9 ARE NOT OF SUFFICIENT SIZE FOR THE 800AMP BREAKER | | | AS SHOWN FROM GENERATOR. | | | 240.4, 310.16. | | | PLEASE ALSO VERIFY THE NEW ALUM FEEDERS FOR F-8 WHICH | | | IS ONLY RATED FOR 205AMPS PER 310.16 AND BREAKER OVER | | | CURRENT PROTECTION IS 250AMPS. | | | | | | 4) NOTE: PLEASE SEE THE EQUIPMENT GROUNDING CONDUCTOR | | | AS SHOWN FOR THE FEEDERS FROM MSBE TO EDPH IS SHOWN AS | | | 2/0 ON RISER AND 1/0 ON MSBE SCHEDULE. | | | PLEASE SEE THE 2/0 ON RISER IS OK, HOWEVER THE 1/0 IS | | | NOT LARGE ENOUGH PER 250.122. | | | PLEASE ADJUST. | | | | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
14 |
Status |
F |
Date |
2007-09-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-22 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-22 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2007-09-22 17:36:30 | 2007-09-22 17:36:30 | | | | | | ** DENIED REVISIONS ** | | | ** PASSED REVISIONS ** | | | | | | ** PLEASE SEE THERE ARE SEVERAL COMMENTS FROM PREVIOUS | | | REVIEWS FOR REVISIONS WHICH STILL NEED TO BE | | | ADDRESSED. | | | ** PLEASE SEE THERE ARE ONLY SOME SHEETS FOR REVISIONS | | | SUBMITTED 8/21 WHICH ARE OK AND WILL BE STAMPED FOR | | | ELECTRICAL. THERE IS A LIST BELOW AT THE END OF REVIEW | | | NOTES OF SHEETS BEING STAMPED AS OK. | | | | | | 1) NOTE: PLEASE SEE REVIEW COMMENTS OF 6/23/07 WHICH | | | REQUESTED REVISED EGRESS PHOTO-METRICS AS THE LIGHTING | | | ON PLANS HAD CHANGED. THE NOTES ON PLANS MENTIONS THE | | | LIGHTING REVISIONS PER REVISED PHOTO-METRICS HOWEVER TO | | | THE DATE NOT REVISED PHOTO-METRICS HAVE BEEN SUBMITTED | | | INCLUDING THE LATEST REVISIONS SUBMITTED ON 9/20/07. LS | | | 101, 708 AND 7.9 | | | | | | 2) NOTE: PLEASE SEE SHEET E-7.01 AS THIS MENTIONS | | | REVISION(S) IN TITLE BLOCK HOWEVER NOT REVISED | | | NUMERICAL DESIGNATION COULD BE LOCATED ON SHEET FOR | | | THIS. | | | | | | 3) NOTE: PLEASE SEE PREVIOUS REVIEW NOTES DATED 6/26/07 | | | WHICH MENTIONED THAT REVISED ENERGY CALCULATIONS AND | | | INPUT DATA REPORT WILL BE REQUIRED FOR REVIEW OF ALL | | | LIGHTING. | | | PLEASE KNOW ANY REVISIONS TO ANY OTHER SYSTEMS WHICH | | | WITH RESPECT TO THE ENERGY CALCULATIONS WILL ALSO BE | | | REQUIRED TO BE REVISED. | | | PLEASE KNOW THE INPUT DATA REPORT INFORMATION WILL BE | | | REQUIRED TO COORDINATE WITH ALL ELECTRICAL AND OTHER | | | SYSTEMS ON PLANS. | | | FBC CHAPTER 13, 13-415.A.1 | | | | | | 4) NOTE: PLEASE SEE AS OF THIS REVIEW: NO PERMITS HAVE | | | BEEN APPLIED FOR WITH RESPECT TO THE LOW VOLTAGE WORK | | | AS SHOWN ON PLANS. | | | SEPARATE PERMITS ARE REQUIRED FOR THE PHONE, CATV ETC. | | | THESE PLANS MAY BE USED FOR REFERENCE AND A | | | *TURN-AROUND* PERMIT HOWEVER APPLICATION AND FEES BASED | | | ON THE SCOPE OF WORK FOR ALL LV SYSTEMS IS REQUIRED. | | | PLEASE KNOW ANY SECURITY SYSTEMS (AKA ALARMS) ARE A | | | SEPARATE PERMIT ALSO, HOWEVER NO PLANS ARE NEEDED FOR | | | *ALARM SYSTEMS ONLY*. ANY CLOSED CIRCUIT TV, ACCESS | | | CONTROLS ETC FOR OTHER TYPES OF SECURITY SYSTEMS DO | | | REQUIRE PERMITS AND PLANS. NO SYSTEMS OF THIS NATURE | | | ARE SHOWN ON PLANS. | | | **PLEASE SEE SOME REVISED SHEETS IN SETS ARE BEING | | | STAMPED OK, HOWEVER PERMITS NEED TO BE APPLIED FOR. IF | | | PERMITS ARE NOT APPLIED, THEN ELECTRICAL PERMIT FOR | | | BASE BUILDING MAY BE PLACED IN A HOLD STATUS FOR | | | ELECTRICAL INSPECTIONS. | | | INFORMATION WILL ALSO BE FORWARDED TO CHIEF ELECTRICAL | | | INSPECTOR TO VERIFY PERMITS IN FIELD. | | | | | | 5) NOTE: PLEASE SEE SHEET E-206 AS SOME SWITCHES ARE | | | SHOWN AS STANDARD SWITCH DEVICES WHEN AUTOMATED ARE | | | REQUIRED. IS THE T NEXT TO BOTH SWITCHES IN ALL THREE | | | STORAGE ROOMS FOR BOTH SWITCHES? | | | 13-415.1.ABC.1.1, .1.2. | | | | | | 6) NOTE: PLEASE SEE REVISIONS SUBMITTED AS OF SEPTEMBER | | | 20TH, 2007 WILL BE ENTERED UNDER THE NEXT REVISION #15 | | | IN OUR SYSTEM. THIS REVISION AND REVIEW WILL BE DONE ON | | | THE SAME DATE OF 9/22/07 AS THIS REVISION. | | | THESE REVIEWS COMMENTS ARE UNDER *REV #14* IN OUR | | | SYSTEM. | | | | | | 7) NOTE: PLEASE SEE SHEET E2.02 AS THERE ARE STILL EXIT | | | LIGHTS WHICH WERE ADDED TO PLANS WITH NO CIRCUITING AND | | | SHOWN DIRECTING OCCUPANTS INTO THE COMMERCIAL TENANT | | | BUILD OUT SPACE WHICH IS NOT PERMITTED. | | | THIS SHEET WILL NOT BE STAMPED PLEASE BE SURE TO | | | COORDINATE WITH OTHER REVISIONS SUBMITTED SEPTEMBER | | | 20TH, 2007. | | | | | | 8) NOTE: REDLINED EQUIPMENT GROUNDING FROM MSBE TO | | | EDPH, AS THIS IS SHOWN AS 1/0 CU WHICH IS NOT RATED FOR | | | THE 1000AMPS. REDLINED 2/0 MIN PER 250.122 | | | THIS WILL BE NOTED AND FAILED IN REVSIONS SUBMITTED ON | | | 9/20/07. REV #15 IN OUR SYSTEM. | | | | | | | | | ** THE FOLLOWING SHEETS ARE STAMPED AND DO NOT NEED TO | | | BE REVISED. SOME ARE SUBMITTED AS REVISIONS SUBMITTED | | | 9/20/07. | | | E0.01, 2.012.01A, 2.02A, 2.03, 2.03A, 2.20A, | | | 2.31,2.32,2.33,6.01 AND 6.02 | | | | | | SHEETS E3.03, 3.04, 3.05, 3.06 AND 5.02 ARE OK, HOWEVER | | | AS NOTED ABOVE IN NOTE #4 LV PERMITS ARE STILL | | | REQUIRED. THESE SHEETS ARE BEING STAMPED ON THE NOTICE | | | OF PERMITS TO BE APPLIED FOR AS NOTED ABOVE. | | | | | | ** SHEETS E- 2.02, 2.04, 2.05, 2.06, 2.17, 2.19, 2.20 | | | AND 7.01 ARE NOT STAMPED PER NOTES ABOVE. | | | | | | *** IMPORTANT** | | | ONCE FIRE REVIEW IS DONE AND OK, NEED TO KEEP ONE SET | | | OF ELECTRICAL SHEETS WHICH ARE STAMPED AS OK, NEED TO | | | BE KEPT FOR FILE COPY. | | | PLEASE DO NOT RELEASE ALL THREE SETS OF ELECTRICAL ** | | | PLEASE KNOW AS THERE ARE SOME ITEMS NOT YET SUBMITTED | | | FOR REVIEW AND THE CHANGES WHICH WILL BE NEEDED FOR | | | SERVICE A COMPLETE REVIEW CAN NOT BE DONE AT THIS | | | TIME. | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-09-22 14:21:45 | 2007-09-22 14:21:45 | | | | | | IN ELEC FOR REVIEW |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
13 |
Status |
F |
Date |
2007-09-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-09 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-09 |
Time |
11:18 |
Sent To |
PC |
|
| Notes |
| 2007-09-09 11:29:48 | 2007-09-09 11:29:48 | | | | | | ** DENIED REVISIONS # 13, 14 ETC. ** | | | | | | 1) NOTE: PLEASE SEE THE REVISED SHEETS SUBMITTED HAVE | | | NOT BEEN CORRECTED TO INCORPORATE COMMENTS FROM REVIEW | | | DATED 6/26/07. | | | PLEASE SEE THERE ARE SEVERAL AREAS ON PLANS WHICH | | | CONTAIN COMMENTS. | | | PLEASE SEE THE REVIEW NOTES FROM 6/26 HAVE BEEN | | | ATTACHED. PLEASE SEE NOTE #12 AS NO TCO, CO, OR | | | ELEVATOR CERTIFICATION WILL BE GRANTED UNLESS MEETING | | | THE NEW STATE LAWS FOR EXISTING AND NEW HIGH-RISE | | | RESIDENTIAL BUILDING. | | | THIS STATE LAW INCLUDES ALL BUILDINGS, EVEN STRUCTURES | | | PERMITTED BEFORE LAW WENT INTO EFFECT. | | | | | | ** PLEASE KNOW NO FURTHER REVISIONS WILL BE STAMPED | | | UNTIL COMMENTS FROM ANY PREVIOUS REVIEWS ARE | | | ADDRESSED. | | | | | | | | | ** AS STATED ON PREVIOUS REVIEWS: IF THERE ARE ANY | | | QUESTIONS, PLEASE DO NOT HESITATE IN CONTACTING THIS | | | OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
12 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-28 |
Time |
12:58 |
Sent To |
PC |
|
| Notes |
| 2007-08-28 13:00:03 | ** DENIED ** | | | | | | LIGHTING R SUBMITTALS | | | | | | 1) NOTE: PLEASE MAKE CORRECTIONS AS NOTED BY THE | | | ENGINEER AND CORRELATE WITH THE SUBMITTED STAMPED | | | PLANS. | | | | | | 2) NOTE: PLEASE SEE THAT ALL LIGHTING SUBMITTALS NEED | | | TO CONTAIN THE LISTING FROM A NRTL ON EACH FIXTURE | | | CLEARLY SHOWN ON EACH. | | | PLEASE SUBMIT THE STAMPED SETS FROM THE ENGINEERS | | | OFFICES AND ONLY SUBMIT THREE SETS FOR REVIEW AND | | | STAMPING. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
11 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-28 |
Time |
12:55 |
Sent To |
PC |
|
| Notes |
| 2007-08-28 12:57:30 | ** DENIED ** | | | | | | SWITCH GEAR SUBMITTALS | | | | | | 1) NOTE: PLEASE MAKE CORRECTIONS AS NOTED BY THE | | | ENGINEER AND CORRELATE WITH THE SUBMITTED STAMPED | | | PLANS. | | | | | | 2) NOTE: A MCB MAY BE REQUIRED ON EDPH, AS THE ATS DOES | | | NOT CONTAIN THE DISCONNECT NEEDED ON THE NORMAL AND | | | EMERGECNY SIDE. | | | PLEASE SEE THE STAMPED PLANS. | | | | | | PLEASE SUBMIT THE STAMPED SETS FROM THE ENGINEERS | | | OFFICES AND ONLY SUBMIT THREE SETS FOR REVIEW AND | | | STAMPING. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
10 |
Status |
F |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
12:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-28 |
Time |
12:52 |
Sent To |
PC |
|
| Notes |
| 2007-08-28 12:54:49 | ** DENIED ** | | | | | | GENERATOR SUBMITTALS | | | | | | 1) NOTE: PLEASE MAKE CORRECTIONS AS NOTED BY THE | | | ENGINEER AND CORRELATE WITH THE SUBMITTED STAMPED | | | PLANS. | | | | | | PLEASE SUBMIT THE STAMPED SETS FROM THE ENGINEERS | | | OFFICES AND ONLY SUBMIT THREE SETS FOR REVIEW AND | | | STAMPING. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
9 |
Status |
N |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-28 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-28 |
Time |
11:41 |
Sent To |
FIRE |
|
| Notes |
| 2007-08-28 11:42:25 | FIRE PUMP SUBMITTAL FROM 4/07 SENT TO FIRE. | | | REMOVED FROM ELEC SUBMITTALS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-26 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-24 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2007-06-26 09:04:53 | | | | | | | *** UNSAT *** | | | | | | ** REVISIONS TO 480 HIBISCUS ST. | | | | | | 1) NOTE: PLEASE SEE THERE ARE NUMEROUS SHEETS WHICH | | | INDICATE REVISIONS ON TITLE BLOCK AS REV 11 BUT THE | | | LAST REVISION SUBMITTED TO THIS OFFICE WAS REVISION #6. | | | WHAT HAPPENED TO 7, 8, 9 AND 10? | | | PLEASE SEE THERE ARE SEVERAL SHEETS WHICH INDICATE SOME | | | CHANGES TO SHEETS AS NOTED IN THE REVISIONS HOWEVER | | | THERE ARE ITEMS WHICH ARE REVISED ON PLANS HOWEVER | | | THERE IS NO INDICATION ON PLANS AT THESE LOCATIONS | | | WHERE THESE ARE REVISED. (NO CLOUDS/NO TRIANGLES). | | | FBC 106.1.2 COORDINATION REQUIRED. | | | | | | 2) NOTE: PLEASE CLARIFY NEW LAYOUT ON GROUND LEVEL AND | | | MEZZ LEVEL AS WHAT USED TO BE THE PREVIOUS ELECTRICAL | | | ROOM IS NOW SHOWN BLANK, WITH A MISSING RATED WALL. | | | PLEASE SE NEW EXIT LIGHTS WHICH DIRECT PEOPLE INTO THIS | | | CLOSED IN AREA ELECTRICAL ROOM. IT APPEARS TO INDICATE | | | AN EGRESS FROM THE GARAGE INTO THE GROUND LEVEL | | | COMMERCIAL TENANT SPACE? | | | FBC 106.1.2 COORDINATION REQUIRED. | | | | | | 3) NOTE: PLEASE SEE THERE ARE SEVERAL NEW EXIT LIGHTS | | | AND OTHER FIXTURES WITH NOT DESIGNATION FOR CIRCUITS, | | | CONTROLS ETC. | | | 240.4.310.16.FBC 106.1.2, 106.3.5.1.2 ETC | | | | | | 4) NOTE: PLEASE SEE TYPICAL CORRIDORS OUTSIDE STORAGE | | | ROOMS WHICH NO AUTOMATED CONTROLS ARE INDICTED FOR | | | LIGHTS. 13-415.1.ABC.1.1,.1.2. THIS IS TYPICAL OF | | | MULTIPLE FLOORS. | | | | | | 5) NOTE: PLEASE SEE SEVERAL NEW LIGHTING CONTROLS ADDED | | | IN ROOMS WHICH INDICATE NOW A STANDARD LIGHTING SWITCH. | | | PLEASE SEE MISSING CONTROLS PER 13-415.1.ABC.1.1, .1.2 | | | | | | 6) NOTE: PLEASE SEE ALL LIGHTING WHICH HAS BEEN REVISED | | | ON PLANS WILL REQUIRE THE ENERGY CALCULATIONS TO BE | | | COMPLETELY REVISED. | | | 13-415.1.AB.1.1, 13-415.2 | | | | | | 7) NOTE: PLEASE KNOW WITH THE REVISED LIGHTING ON PLANS | | | WILL REQUIRE ALL THE REQUIRED EGRESS LIGHTING TO BE | | | REVISED. | | | PLEASE SUBMIT THE REVISED MINIMUM LEVELS UNDER NORMAL | | | AND UNDER EMERGENCY. | | | LS 101 7.8, 7.9 | | | | | | 8) NOTE: PLEASE SEE THERE ARE CHANGES TO POOL PATIO | | | AREAS FOR LIGHTS WHICH ARE NOT NOTED ON EXPLANATION | | | LETTERS AND LOCATIONS WHERE LIGHTS ARE NOT REMOVED? | | | PLEASE CLARIFY WHERE THESE LIGHTS ARE? HOW ARE THESE | | | AREAS GOING TO BE LIT? PLEASE SEE ELECTRICAL PANELS, | | | TRANSFORMERS FOR POWER WHICH HAVE BEEN REMOVED BUT THE | | | PLANS DO NOT INDICATE THIS OR NEW LOCATIONS? | | | PLEASE SEE THE REVISION EXPLANATION LETTER DOES NOT | | | MENTION SEVERAL OF THESE ITEMS. | | | FBC 106.1.2 REQUIRED COORDINATION. | | | | | | 9) NOTE: PLEASE SEE THE SUBMITTED EXPLANATION TO | | | REVISIONS LETTER STATE SEVERAL SHEETS WHICH WERE NOT | | | SUBMITTED IN PACKAGE AND THERE ARE SHEETS SUBMITTED | | | WHICH ARE NOT LISTED. | | | PLEAS COORDINATE. | | | FBC 106.1.2 | | | | | | 10) NOTE: PLEASE SEE 221-233 APPEAR TO BE OK, HOWEVER | | | INFORMATION FOR PHOTO-METRICS AND COORDINATION OF | | | REVISION NUMBERS IN TITLE BLOCKS NEED TO BE ADDRESSED. | | | | | | 11) NOTE: PLEASE SEE SHEETS 602 AND 603 WHICH LETTER | | | STATES REVISED FEEDERS FOR ALUM, YET PLANS DO NOT SEEM | | | TO HAVE ANY DESIGNATIONS OR REVISIONS FOR THIS? | | | | | | 12) NOTE: *** IMPORTANT** PLEASE SEE ATTACHED INDUSTRY | | | BULLETIN WITH RESPECT TO THE NEW HB 7121 WHICH REQUIRES | | | FUEL FOR GENERATOR, EMERGENCY LIGHTS, EXIT LIGHTS, AND | | | ONE STRETCHER ACCESSIBLE ELEVATOR FOR A PERIOD OF FIVE | | | DAYS. PLEASE SEE THIS IS A NEW STATE LAW REQUIRED FOR | | | NEW CONSTRUCTION, EXISTING CONSTRUCTION, EXISTING | | | BUILDING WHICH MEET THE HIGH-RISE CRITERIA. | | | THE SHEET IS ATTACHED AND THE ENTIRE HOUSE BILL CAN BE | | | LOCATED ON THE STATE LEGISLATIVE WEBSITE. | | | | | | 13) NOTE: PLEASE KNOW AS THERE ARE NUMEROUS SHEETS | | | WHICH NEED COORDINATION OF REVISED ITEMS, NOT ALL CAN | | | BE GIVEN IN DETAIL FOR EACH ITEM. ONE SET HAS REDLINED | | | AREAS FOR SOME OF THESE LOCATIONS. | | | | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-06-24 15:53:05 | 200-06-024 15:53:05 | | | ELEC SHEETS OF REVISIONS IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2006-12-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-12-09 |
Time |
19:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-12-07 |
Time |
19:27 |
Sent To |
|
|
| Notes |
| 2006-12-09 19:54:55 | REVISION #10. STAMPED. | | | | | | *** SHEETS E204, 205 AND 206 NOT STAMPED AND VOIDED AS | | | THESE SHEETS WERE NOT REVISED IN ANY FASHION AND NO | | | REVISION WAS INDICATED ON TITLE BLOCKS. THE LAST | | | REVISION FOR THESE SHEETS WERE #6 BEFORE PERMIT WAS | | | ISSUED. | | 2006-12-09 19:22:53 | REVIEW IN PROGRESS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
N |
Date |
2006-09-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-09-27 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-09-27 |
Time |
07:23 |
Sent To |
E |
|
| Notes |
| 2006-09-27 00:00:00 | *** PLEASE SEE THE RESUB FOR THE TEMP | | | ELECTRICAL SERVICE WAS SUBMITTED AS A | | | REVISION UNDER THIS PERMIT. PLANS ARE | | | BEING GIVEN BACK TO NAT HEALY. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2006-08-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-23 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-23 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2006-08-23 00:00:00 | ONLY NEED TO STAMP OTHER TWO SETS OF | | | MEP'S. | | | ELECTRICAL REVIEW HAS PASSSED. | | | ALL THREE SETS STAMPED FOR ELECTRICAL. | | | NOTICED SHEET P2.04 STILL MISSING FROM | | | ONE SET. CALLED NAT HEALY FOR NEW SHEET | | | TO COMPLETE SET. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2006-08-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-08-20 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-08-18 |
Time |
19:36 |
Sent To |
|
|
| Notes |
| 2006-08-21 00:00:00 | MOST ITEMS FROM NOTES ON 8/18 ARE | | | ADDRESS, THREE SETS OF PLANS ARE NOW | | | COMPLETE. NEED STAMPING AND THEN | | | ELECTRICAL CAN GO INTO A PASSED STATUS. | | 2006-08-20 00:00:00 | ** UNSAT ** | | | | | | ** PLEASE SEE NOTES ADDED TO THIS REVIEW | | | "IN" STOP ON FRIDAY 8/18/06. | | | PLANS TO REMAIN IN "F" STATUS UNTIL ALL | | | ITEMS FROM 8/18/06 ARE ADDRESSED AND | | | SUBMITTED. | | | PLEASE KNOW THIS REVIEWER IS UNABLE TO | | | TO STAMP ALL THREEE SETS OF PLANS AS | | | ONLY ONE SET IS COMPLETE AT THIS TIME. | | | | | | | | | ** ALL ELECTRICAL COMMENTS ON PLANS ARE | | | ADDRESSED AND THE ONE COMPLETE SET OF | | | ELECTRICAL PLANS ARE STAMPED. OK. | | | | | | ** STILL NEED TO REVIEW ENERGY | | | CALCULATIONS. | | | | | | ** TEMP IN "F" STATUS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | 2006-08-18 00:00:00 | CALLED ARCHITECT AND OWNER'S | | | REPRESENATIVE AFTER GOING THROUGH ALL | | | BOXES AND M>E>P>FA>AND FP PLANS. | | | MENTIONED THE FOLLOWING WAS NEEDED AND | | | WHAT WAS MISSING. | | | | | | 1) NOTE: MISSING THE FOLLOWING SHEETS | | | FROM SETSOF MEP'S. | | | | | | SET #1 MISSING | | | E1.01, 2.09,2.12,2.15,2.18, 2.20A, | | | 2.21,2.24,2.27. ELECTRICAL SHEETS. | | | P 2.04, 2.32 PLUMBING SHEETS. | | | | | | SET #2 MISSING | | | E2.36 AND FA 1.03 | | | | | | | | | 2) NOTE:PLEASE SEE ALL 6 SETS OF SOIL | | | REPORTS (ONLY 3 NEEDED) ARE INFACT | | | RAISED SEALS OF PHOTO-COPIED SIGNATURES | | | FROM THE ENGINEER. THESE ARE REQUIRED TO | | | HAVE AN ORIGINAL SIGNATURE PER FS | | | 471.025, FAC 61G15-23.002 | | | | | | 3) NOTE: PLEASE SEE ALL THREE COPIES OF | | | SURVEY'S ALSO CONTAIN A RAISED SEAL OVER | | | PHOTO-COPIED SIGNATURES. | | | FS 472.025 | | | | | | 4) NOTE: PLEASE SEE NUMEROUS VOLUMES FOR | | | STRUCTURAL CALCULATIONS WERE SUBMITTED. | | | WE ONLY NEED THREE OF EACH, THE | | | FOLLOWING WAS SUBMITTED: | | | | | | VOL I, 5 SETS, ONLY 2 SIGNED AND SEALED. | | | VOL II, 6 SETS, NOT SIGNED, OR SEALED. | | | VOL III, 4 SETS, NOT SIGNED OR SEALED. | | | VOL IV, 5 SETS, NOT SIGNED, OR SEALED. | | | VOL V, 3 SETS, NOT SIGNED OR SEALED. | | | VOL VI, 3 SETS , NOT SIGNED OR SEALED. | | | VOL VII, 3-SETS , NOT SIGNED OR SEALED. | | | ** PLEASE KNOW, ONLY THREE OF EACH ARE | | | NEEDED. ALL ADDITIONAL SETS/VOL'S WILL | | | BE RETURNED. | | | | | | 5) NOTE: MISSING THREE COMPLETE SETS OF | | | FIRE PUMP AND FIRE PUMP CONTROLLER. ONLY | | | ONE COMPLETE SET FOR ALL NEW WAS | | | SUBMITTED. | | | MADE COPIES OF THE ONE CORRECT SET, HOLE | | | PUNCHED, PLACED IN BINDERS AND TABBED | | | EACH FOR FP, FPC, GEN, AND ATS. | | | | | | 6) NOTE: PLEASE SEE ALL THREE SETS OF | | | THE 2004 FBC ENERGY CALCULATIONS ARE | | | PHOTO-COPIES OF SIGNED AND SEALED | | | CALCULATION SHEETS. ALL THREE BINDERS | | | CONTAIN THE SAME. | | | FS 471.025, FAC 61G15-23.002 | | | | | | 7) NOTE: RESPONSE'S FROM DEL LOS REYES | | | ENGINEERING WHICH ALSO CONTAINS | | | STRUCTURAL INFORMATION AND SOME OF THE | | | VOL'S FOR STRUCTURAL CALCULATIONS STILL | | | CONTAIN A SEAL WHICH IS NO LONGER VALID | | | IN THE STATE OF FLORIDA PER RULING UNDER | | | THE FLORIDA BOARD OF PROFESSIONAL | | | ENGINEER'S DATED FEB 04. 61G15-23.001 | | | ALL SEALS AFTER DEC 31ST, 2005 SHALL | | | CONTAIN THE WORDING "LICENSE". | | | "CERTIFICATE" IS NO LONGER ACCEPTABLE. | | | | | | ** A MEETING HAS BEEN SCHEDULE FOR | | | MONDAY 8AM TO 12PM. | | | | | | ONE ROLL OF ELECTRICAL IS COMPLETE AND | | | IN ELECTRIC FOR REVIEW. | | | REVIEW IN PROGRESS. | | | | | | IF THERE ARE ANY QUESTIONS ON THE ABOVE | | | PLEASE CALL. | | | | | | DEWEY PALMER | | | 561-805-6717 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2006-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-07-30 |
Time |
18:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-07-30 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2006-07-30 00:00:00 | ONE ROLL IN ELECTRIC FOR REVIEW. | | | REVIEW IN PROGRESS. | | | *********** UNSAT 3RD REVIEW ********** | | | | | | | | | ** THIS OFFICE HAS STATED ON NUMEROUS | | | OCCASIONS FOR THE DESIGN TEAM TO TAKE | | | SOME ADDITIONAL TIME BEFORE RESUBMITTING | | | PLANS AND EVEN AFTER RESUBMITTING PLANS | | | TO GO OVER PLANS CAREFULLY. THIS OFFICE | | | HAS STATED IF DESIGN TEAM FINDS ITEMS | | | BEFORE REVIEWS ARE STARTED THEN THOSE | | | SHEETS MAY BE CHANGED OUT. PLEASE SEE | | | THE FOLLOWING COMMENTS BELOW. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES WHICH NEED TO | | | BE ADDRESSED. | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW AND NEW | | | NOTES ARE ADDED TO THE LOWER PORTION OF | | | REVIEW COMMENTS. | | | | | | | | | CITY PALMS | | | 10-STORY CONDO | | | | | | 1)NOTE: NO. PLEASE SEE COMMENTS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | NOTE #1, NO, PLEASE SEE NEW NOTE | | | PERTAINING TO THE NEW 2004 FBC AND | | | CHAPTER 13. | | | | | | ** PREVIOUS REVIEW ** | | | PLEASE KNOW, PLANS WERE SUBMITTED FOR | | | "PLAN REVIEW" ONLY AND WERE NOT | | | SUBMITTED FOR PERMIT BEFORE THE CODE | | | CHANGE OF OCT 1ST, 2005 TO THE NEW | | | 2004 FBC. | | | PLEASE SEE THAT ANY CHANGES WILL BE | | | NEEDED WHEN SUBMITTING FOR PERMIT. | | | | | | 2)NOTE: OK. | | | | | | 3)NOTE: OK. | | | | | | 4)NOTE: OK. | | | | | | 5)NOTE: OK, HOWEVER PLEASE KNOW THE YEAR | | | STATED ON PREVIOUS NOTE FOR NFPA-20 WAS | | | 1999 WHICH WAS MIS-STATED. THIS SHOULD | | | HAVE BEEN 2003. IN EITHER CASE THIS CAN | | | BE REDLINED AND NOTHING FROM THE 1999 TO | | | THE 2003 APPEARED TO CHANGE DESIGN OR | | | AFFECT PLANS. | | | | | | | | | 6)NOTE: OK. | | | | | | 7)NOTE: NO, PLEASE SEE PHOTO-METRICS | | | PROVIDED. PLEASE SEE SHEETS FOR CORIDORS | | | AND STAIRS SHOW LEVELS 7-8 ONLY. | | | SEE SHEETS WHICH INDICATE GRND FLOOR AND | | | 2-5 ONLY CONTAIN SOME AREAS. PLEASE SEE | | | MSSING OTHER LEVELS ETC. | | | PLEASE SUBMIT COMPLETE PHOTO-METRICS FOR | | | ALL COMMON AREA EGRESS PATHS. | | | IF ALL CORRIDORS GOING UP THROUGH | | | BUILDIGN ARE THE SAME, THESE CAN BE ON | | | TYPICAL FLR DETAIL FOR FLRS "X"-"?". | | | | | | ** PREVIOUS REVIEW NOTE ** | | | NOTE #7NO, PLEASE SEE SOME | | | WERE SUBMITTED FOR GARAGE AND CORRIDORS, | | | HOWEVER STAIRWAYS COULD NOT BE LOCATED. | | | PLEASE ALSO KNOW, LEVELS UNDER EM POWER | | | SHALL BE PROVIDED. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE PROVIDE COMPLETE "PHOTO-METRICS" | | | FOR ALL CORRIDORS, STAIRWELLS AND EGRESS | | | AREAS PER 2003 NFPA-101 7.8 AND 7.9. | | | PLEASE SEE A MIN OF 10 FT CANDLES IS NOW | | | REQUIRED FOR STAIR TOWERS UNDER NORMAL | | | EGRESS CONDITIONS. | | | | | | 8)NOTE: OK. | | | | | | | | | 8)NOTE: OK. | | | | | | 9)NOTE: OK. | | | | | | 10)NOTE: OK. | | | | | | 11)NOTE: OK. | | | | | | 12)NOTE: OK. | | | | | | 13)NOTE: OK. | | | | | | 14)NOTE: OK. | | | | | | 15)NOTE: OK. | | | | | | 16)NOTE: OK. | | | | | | 17)NOTE: OK. | | | | | | 18)NOTE: OK. | | | | | | 19)NOTE: OK. | | | | | | 20)NOTE: OK, HOWEVER SEE NEW NOTE. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SHOW CIRCUITING FOR ALL UNITS AND | | | CORRELATE WITH THE PANEL SCHEDULES | | | SUBMITTED. PLEASE KNOW, CODE COMPLIANCE | | | FOR SOME ITEMS CAN NOT BE DONE AT THIS | | | TIME. | | | | | | 21)NOTE: OK. | | | | | | 22)NOTE: OK. | | | | | | 23)NOTE: OK. | | | | | | 24)NOTE: OK. | | | | | | 25)NOTE: OK. | | | | | | 26)NOTE: OK. | | | | | | 27)NOTE: OK. | | | | | | 28)NOTE: OK. | | | | | | 29)NOTE: OK. | | | | | | 30)NOTE: OK. | | | | | | 31)NOTE: OK. | | | | | | 32)NOTE: OK. | | | | | | 33)NOTE: OK. | | | | | | 34)NOTE: OK. | | | | | | 35)NOTE: OK. | | | | | | 36)NOTE: OK. | | | | | | 37)NOTE: OK, HOWEVER NOTE PERTAINING TO | | | THE GROUNDING AND THE GENERATOR BEING | | | SEPARATELY DERIVED WAS REMOVED. THE NOT | | | SHOULD HAVE REMAINED, ONLY ADJUSTED TO | | | READ GENERATOR IS SEPARATELY DERIVED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | NOTE #37 NO, PLEASE SEE NO | | | SPECS WERE SUBMITTED. PLEASE ALSO SEE | | | RISER INDICATES THE 4-POLE ATS, HOWEVER | | | NOTES MENITON THIS IS NOT A SEPARATELY | | | DERIVED GENERATOR? PLEASE SEE AS A | | | 4-POLE ATS, THE GEN IS "SEP DERIVED" AND | | | GROUNDING SHALL BE DONE ACCORDINGLY. | | | PLEASE SEE MISSING BONDING AT FIRST | | | MENAS OF DISCONNECT , EQUIPMENT GROUNDD | | | ETC. PLEASE SEE NFPA-110 6.2.15*. PLEASE | | | VERIFY WITH MANUFACTURE OF EQUIPMENT. | | | PLEASE SEE NEW NOTES FOR ATS AND MAIN. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SUBMIT ALL INFORMATION | | | FOR GENERATOR/ ATS. PLEASE SUBMIT THE | | | SPECS/CUT FROM MANUFACTURE. | | | PLEASE VERIFY OF THE ATS WILL BE A | | | 4-POLE SWITCH. | | | PLEASE SEE 700.7D AND IF YOU HAVE THE | | | HANDBOOK, SEE EXPLANATION OF ARTICLE. | | | I HAVE ATTACHED BOTH, JUST IN CASE. | | | | | | (D) GROUND FAULT. TO INDICATE A GROUND | | | FAULT IN SOLIDLY GROUNDED WYE | | | EMERGENCY SYSTEMS OF MORE THAN 150 VOLTS | | | TO GROUND AND CIRCUIT-PROTECTIVE | | | DEVICES RATED 1000 AMPERES OR MORE. THE | | | SENSOR FOR THE GROUND-FAULT SIGNAL | | | DEVICES SHALL BE LOCATED AT, OR AHEAD | | | OF, THE MAIN SYSTEM DISCONNECTING | | | MEANS FOR THE EMERGENCY SOURCE, AND THE | | | MAXIMUM SETTING OF THE SIGNAL | | | DEVICES SHALL BE FOR A GROUND-FAULT | | | CURRENT OF 1200 AMPERES. INSTRUCTIONS | | | ON THE COURSE OF ACTION TO BE TAKEN IN | | | EVENT OF INDICATED GROUND FAULT | | | SHALL BE LOCATED AT OR NEAR THE SENSOR | | | LOCATION. | | | | | | ALTHOUGH 700.26 INDICATES THAT | | | GROUND-FAULT PROTECTION OF EQUIPMENT IS | | | NOT | | | REQUIRED ON THE ALTERNATE SOURCE FOR | | | EMERGENCY SYSTEMS, GROUND FAULTS CAN | | | OCCUR ON SUCH SYSTEMS, AND THEY CAN | | | RESULT IN EQUIPMENT BURNDOWN. BECAUSE | | | OF THE EMERGENCY NATURE OF SUCH SYSTEMS, | | | AUTOMATIC DISCONNECT IN THE EVENT | | | OF A GROUND FAULT IS INAPPROPRIATE. | | | DETECTION OF SUCH A FAULT, HOWEVER, IS | | | DESIRABLE SO THAT THE CONDITION CAN BE | | | CORRECTED. | | | IN MY READING AND THE INFORMATION FROM A | | | COULE OF MANUFACURES OF ATS SWITCHES, A | | | 4-POLE ATS IS REQUIRED. PLEASE RESERCH | | | THE INFORMATION AND ADJUST. | | | | | | 38)NOTE: OK. | | | | | | 39)NOTE:OK, HOWEVER SEE NOTE ABOVE | | | ABOUT THE GEN BE SD.PLEASE ALSO SEE THAT | | | SINCE ONLY ONE "DRAWING KEYNOTE RISER' | | | IS SUBMITTED FOR REVIEW. PLEASE SEE NOTE | | | #11 MISPRINTS STATING 230.79 TWICE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | NOTE #39 YES/ NO, PLEASE NOW | | | SEE TWO SETS OF DRAWING KEYNOTES, WHICH | | | AS NOTED IN ONE SET MOST DO NOT | | | CORRELATE WITH RISER DIAGRAM. PLEASE SEE | | | SOME COMMENTS FOR OTHER. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE COMPLETE DRAWING KEYNOTES TO | | | CORRELATE WITH PLANS. | | | | | | 40)NOTE: OK. | | | | | | 41)NOTE: OK. | | | | | | 42)NOTE: OK. | | | | | | | | | ************************************** | | | ************************************* | | | ******** NEW NOTES 2ND REVIEW ********* | | | | | | | | | 43) NOTE: NO, PLEASE SEEE THE ONLY TYPE | | | WRITTEN RESPONSE WAS DATED FEB 2006. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE KNOW, A FULL AND | | | COMPLETE TYPE WRITTEN RESPONSE FROM THE | | | DESIGN TEAM WHICH RESPONSES TO THE PLANS | | | REVIEWERS COMMENTS WILL HELP IN | | | EXPEDITING THE PLAN REVIEW PROCESS. THIS | | | NUMERICAL REPONSE WILL HELP TO | | | ALLEAVIATE ANY BACK AND FORTH QUESTIONS | | | OR CONFUSION. | | | NO, RESPONSE LETTERS WERE SUBMITTED WHEN | | | PLANS WERE BROUGHT BACK FOR REVIEW. | | | | | | 44) NOTE: NO, SAME NOTE. PLEASE SEE THE | | | SAME BOOKS AND CALCULATIONS WERE | | | SUBMITTED BACK WITH ANY CORRECTIONS OR | | | CHANGES. | | | PLEASE SEE MOST OF THE BOOKS AND | | | CALCULATIONS ARE NOT SIGNED, DATED OR | | | SEALED AND THE ONES THAT ARE SIGN/SEALED | | | ARE STILL THE SAME. PLEASE SEE THIS SEAL | | | WITH THE WORDING OF "CERTIFICATE" IS NO | | | LONGER ACCEPTABLE. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE ALL PLANS, SHEETS, | | | DOCUMENTS BEING SIGNED, DATED OR SEALED | | | BY A LICENSED PE, SHALL ONLY CONTAIN A | | | SEAL WITH THE WORDING OF "LICENSE". | | | PLEASE SEE A RULING BY THE FLORIDA BOARD | | | OF PROFESSINAL ENGINEERS DATED IN | | | FEBUARY "04", RULED IN 61G15-23.001, | | | THAT ALL SEALS SHALL NO LONGER USE | | | "CERTIFICATE" IN SAID SEAL. PLEAS KNOW, | | | AN EXTENSION WAS GIVEN TO THE DATE OF | | | DEC. 31ST , 2005.PLEASE SEE THIS IS | | | NOT A COMMENT FOR STEVEN FELLER AS SEAL | | | IS CORRECT. PLEASE SEE OTHER DOCUMENTS | | | SUBMITTED DO CONTAIN THE SEAL WHICH IS | | | NO LONGER ACCEPTABLE. | | | PLEASE SEE DE LOS REYES ENG.AND ANY | | | OTHERS WHICH MAY STILL BE UTILIZING OLD | | | SEAL. | | | PLEASE KNOW, THIS COMMENT IS MADE FOR | | | ALL PLANS AND DOCUMENTS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 45) NOTE: NO, PLEASE SEE CALCULATIONS | | | ARE STILL SHOWING ALL CALCULATIONS FROM | | | THE 2001 FBC. PLEASE SEE THESE WERE | | | SIGNED AND SEALED AFTER THE CODE CHANGE | | | YET STILL WERE DONE UNDER THE 2001 FBC. | | | PLEASE SEE CALCULATIONS CAN NOT BE | | | VERIFIED FOR COMPLIANCE OF LIGHTING | | | LEVELS, CONTROLS ETC. | | | PLEASE BE SURE THE CALCUALTIONS MEET THE | | | PERFORMANCE CALCULATIONS PER | | | 13-415.1.AB.1,13-415.2.ABC.1, TABLES | | | 415.2.C.1, 415.2.B.1 ETC | | | PLEASE ALSO SEE NUMEROUS AREAS/ROOMS | | | WHICH FALL UNDER SEPARATE SPACES ON | | | MULTIPLE FLOORS WHICHSTIL DO NOT | | | CONTAIN REQUIRED CONTROL DEVICES. PLEASE | | | KNOW, IN A MEETING HELD BEFORE PLANS | | | WERE SUBMITTED THE FUTURE RETAIL | | | COMMERICAL SPACES WERE SHOWN WITH TIME | | | CLOCKS AND OVER RIDES DEVICES AND THE | | | COMMENT WAS MADE BY THIS REVIEWER THAT | | | ONLY THE TC'S WERE NOT REQUIRED IF AN | | | TIMED DEVICE OR OCCUPANCY SENSOR WAS | | | PRESENT. PLEASE SEE ALL LIGHTING | | | CONTROLS WERE REMOVED COMPLETELY>??? | | | PLEASE SEE SECTION BELOW FOR SEPARATE | | | SPCES. | | | MOST OF THESE AREAS HAVE BEEN REDLINED | | | AND HIGHLIGHTED FOR MISSING CONTROLS | | | REQUIRED. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE FBC 2004 CHAPTER | | | 13, 13-415.1.ABC.1.1, &.2, &.3. | | | PLEASE SHOW AND PROVIDE DEVICES, | | | CONTROLS ETC FOR ALL AREAS NOW REQUIRED | | | TO CONTAIN ENERGY CONSERVATION MEASURES. | | | PLEASE SEE 13-413.1ABC.1 AND PROVIDE | | | NOTES/WORST CASE FOR VOLTAGE DROP. | | | PLEASE SEE 13-415.1.ABC.2 FOR AREA | | | LIGHTING. | | | PLEASE SEE THESE CHANGES ARE COMPLETELY | | | DIFFERENT FORM THE 2001 FBC. | | | THESE CHANGES BECAME FEDERALLY MANDATED | | | FOR ALL STATES TO COMPLY IN THE NEXT | | | CODE CYCLE/CHANGE. THIS FEDERAL MANDATE | | | WAS PASSED JULY 2004 | | | PLEASE SEE NOTE #1 FROM PREVIOUS REVIE | | | MENTIONED TO SEE ALL 2004 FBC FOR ALL | | | CHANGES IN DESIGN AS PROJECT WAS NOT | | | SUBMITTED FOR PERMIT UNDER THE 2001 FBC. | | | | | | 46) NOTE: OK. | | | | | | 47) NOTE: OK, HOWEVER SEE NEW NOTES DUE | | | TO INFORMATION SUBMITTED FOR GENERATOR. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | A) PLEASE SEE NFPA-110, 7.9.3.1, | | | GALVANIZED LINES SHALL NOT BE USED FOR | | | PIPNG TO GENERATOR. THIS IS NOTED FOR | | | PLUMBING/ ENGINEERING AS SOME LOCATIONS | | | IN THE JURISDICTION HAS INSTALLED THESE | | | AND HAVE HAD TO CHANGE TYPES OF PIPING. | | | PLEASE KNOW THIS IS A NOTE AT THIS TIME | | | FOR INFORMATIONAL PURPOSE ONLY. | | | B) PLEASE ALSO SEE NFPA-20, NFPA-110 , | | | NOTES AND SPECS FOR FUEL TYPE AND | | | STORAGE WAS NOTE SUBMITTED, PLEASE SEE | | | MIN RUNNING TIME CAN NOT BE VERIFIED. | | | PLEASE SEE 6-6.2 FOR A MIN OF 8 HRS | | | @100% ALONG WITH ALL OTHER MIN REQUIRED | | | LIFE SAFETY LOADS. | | | THE AMOUNT OF FUEL, AND GPH SHOULD BE | | | NOTED ON PLANS. ONE OF THE DRAWING KEY | | | NOTES MENTIONS 500 GAL TANK?TBD. | | | | | | 48) NOTE: OK. | | | | | | 49) NOTE: NO, PLEASE SEE SOME FIXTURE | | | DESIGNATIONS ARE STILL NOT ON PLANS. | | | PLEASE SEE REDLINED PLANS. EXAMPLE: | | | PLEASE SEE FIXTURE ON 2.04, COMM #4 | | | SPACE. PLEASE SEE SOME FIXTURES ON | | | PLANS DO NOT CONTAIN FIXTURE | | | DESIGNATIONS. | | | "REDLINED ON PLANS" | | | | | | 50) NOTE: OK. | | | | | | 51) NOTE: OK. | | | | | | 52) NOTE: OK. | | | | | | 53) NOTE: OK. SEE NEW NOTES. | | | | | | 54) NOTE: OK. | | | | | | 55) NOTE: NO, PLEASE SEE THAT THE | | | GENERATOR IS A SD SYSTEM AND THE FIRST | | | MEANS OF DISCONNECT PER 250.24B IS NOW | | | THE BREAKER(S) LOCATED ON THE GEN. | | | PLEASE SEE FEEDERS F-8 AND F-9 AS THESE | | | WILL BOTH REQUIRED "EQUIPMENT GROUNDING | | | CONDUCTORS". | | | 210.110,250.24B,250.122 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PREVIOUS NOTE WITH | | | RESPECT TO THE ATS AND 4-POLE, | | | SEPARATELY DERIVED SYSTEM. | | | PLEASE SEE 250.6,250.24B AND 250.122 FOR | | | SIZING ANY EQUIPMENT GORUNDING | | | CONDUCTORS. | | | | | | 56) NOTE: OK. | | | | | | 57) NOTE: OK. | | | | | | 58) NOTE: NO, SAME COMMENT, THIS WAS | | | REDLINED ON PLANS ONCE AGAIN. | | | PLEASE SEE "LOAD SUMMARY" ON E5.01, | | | PLEASE SE "*" AS NOTE, AND ADDED "*" | | | NEXT TO THE LINE FOR FIRE PUMP. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE LOAD SUMMARY FOR | | | FIRE PUMP ON RISER WHICH CONTAINS AN "*" | | | ASTERISK FOR NOTE OF MAGNETIC ONLY 6X | | | LR, HOWEVER THIS "*" IS NOT ABOVE FOR | | | FIRE PUMP. SEE REDLINES THIS IS NOTED AS | | | PLANS ARE COMING BACK FOR COMMENTS. | | | | | | 59) NOTE: OK. | | | | | | 60) NOTE: OK. | | | | | | 61) NOTE: NO, THIS IS YET TBD. THIS DOES | | | NOT NEED TO BE DONE OR NOTED ON PLANS | | | NOW. IF INFORMATION WAS OBTAINED FROM | | | THE LAST MEETING PLEASE PLACE ON RISER. | | | PLEASE KNOW THE ARCHITECT WAS GOING TO | | | CALL TO FIND THIS OUT. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE ELEVATION FOR | | | EPSS. PLEASE SEENFPA-110 7.2.3*,THE | | | ELEVATION OF THE EPSS SHALL BE 6" ABOVE | | | THE "SLOSH" PREDICATION LEVELS. | | | "SEA, LAKE, OVERLAND SURGES BY | | | HURRICANCES. CHARTS BASED ON SURGES FROM | | | A CAT 4 STORM. | | | | | | 62) NOTE: OK, HOWEVER PLEASE BE SURE TO | | | DO THE SAME. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | WHEN AND BEFORE RESUBMITTING | | | PLANS, PLEASE COMPLETELY REMOVE ANY AND | | | ALL OLD/VOIDED SHEETS FROM SETS. PLEASE | | | ONLY INSERT ONLY NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STMAPING. | | | PLEASE KNOW, THIS WAS DONE ON THIS | | | SUBMITTAL. | | | | | | *************************************** | | | ****** NEW NOTES 3RD REVIEW ********* | | | | | | 63) NOTE: PLEASE KNOW,THIS IS THE FIRST | | | REVIEW WHERE MANUFACTURE SPECS/CUT | | | SHEETS HAVE BEEN SUBMITTED FOR A | | | COMPLETE REVIEW OF THE GENERATOR. PLEASE | | | SEE THAT PLANS AND DESIGN HAS CHANGED | | | FROM PREVIOUS PLANS WHICH CONTAINED A | | | DAY TANK LOCATED IN THE ROOM. PLEASE SEE | | | NFPA-20 (2003)OR 1999 AS BOTH REQUIRE | | | THE SAME. | | | 9.6.2.2 THE FUEL SUPPLY CAPACITY SHALL | | | BE SUFFICIENT TO PROVIDE 8 HOURS OF FIRE | | | PUMP OPERATION AT 100 PERCENT OF THE | | | RATED PUMP CAPACITY IN ADDITION TO THE | | | SUPPLY REQUIRED FOR OTHER DEMANDS.(2003) | | | OR | | | 6-6.2* (1999) | | | THESE POWER SOURCES SHALL COMPLY WITH | | | SECTION 6-4 AND SHALL MEET THE | | | REQUIREMENTS OF LEVEL 1, TYPE 10, CLASS | | | X SYSTEMS OF NFPA 110, STANDARD FOR | | | EMERGENCY AND STANDBY POWER SYSTEMS. THE | | | FUEL SUPPLY CAPACITY SHALL BE SUFFICIENT | | | TO PROVIDE 8 HOURS OF FIRE PUMP | | | OPERATION AT 100 PERCENT OF THE RATED | | | PUMP CAPACITY IN ADDITION TO THE SUPPLY | | | REQUIRED FOR OTHER DEMANDS. | | | | | | ** PLEASE KNOW UPON THE REVIEW OF SPECS, | | | THE GENERATOR SHOWS A CONSUMPTION OF | | | 119GPH OR 450LPH. PLEASE SEE BASED ON A | | | 500 GAL SUB- BASE TANK THIS WOULD ONLY | | | PROVIDE ENOUGH FUEL FOR 4.20 HRS. PLEASE | | | ADJUST GENERATOR FOR ONE THAT WILL RUN | | | ON SUBSTANTIALLY LESS FUEL OR INCREASE | | | TANK SIZE. | | | PLEASE SUBMIT SPEC/MANUFACTURE SHEETS ON | | | FUEL TANK IF GOING TO A LARGER TANK OR | | | SUBMIT SPECS/MANIFACTURE SHEET IF | | | CHANGING GENERATOR. | | | | | | 64) NOTE: PLEASE SEE UNIT "B1" MISSING | | | CIRCUIT #22 ON PANEL SCHEDULE. (THIS CAN | | | BE REDLINED). | | | | | | 65) NOTE: PLEASE SEE ATTACHED COPY OF | | | THE FS 553.80(2)(B) WIHT RESPECT TO | | | DESIGN PROFESSIONALS AND REPEAT COMMENTS | | | FOR CODE COMPLIAMCE. | | | PLEASE KNOW THIS IS ONLY A NOTICE GIVEN | | | AT THIS TIME. | | | | | | 66) NOTE: WHEN RESUBMITTING PACKAGES, | | | PLEASE PLACE ALL SPEC/MANUFACTURES CUT | | | SHEETS IN BINDERS WITH TABS/LABELS FOR | | | EASY LOCATING AND REVIEW. PLEASE SEE | | | MANY SHEETS ARE ONLY PLACED INDIVIDUALLY | | | IN BOXES OR IN FOLDERS. | | | PLACING PRODUCT APPROVALS AND SPEC IN | | | BINDERS WOULD GREATLY HELP IN THE REVIEW | | | PROCESS ALSO. | | | | | | ** PLEASE SEE LOCATIONS ON PLANS IN | | | WHICH MANY OF THE ABOVE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS OF COMMENTS. | | | | | | ** PLEASE BE AWARE OF ANY COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT COMPLETED PLANS FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2006-05-08 |
Time |
19:48 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2006-05-04 |
Time |
20:04 |
Sent To |
|
|
| Notes |
| 2006-05-08 00:00:00 | REVIEW IN PROGRESS | | | *********** UNSAT ************ | | | | | | ** 2ND REVIEW, 1ST REVIEW UNDER PERMIT. | | | PLEASE KNOW, WILL ALSO HAVE ONE FREE | | | RESUB FOR NEXT REVIEW. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS | | | REVIEW AND SOME NEW NOTES WHICH NEED TO | | | BE ADDRESSED. | | | PLEASE SEE NOTES BELOW ARE TAKEN | | | DIRECTLY FROM PREVIOUS REVIEW AND NEW | | | NOTES ARE ADDED TO THE LOWER PORTION OF | | | REVIEW COMMENTS. | | | | | | *** UNSAT *** | | | | | | CITY PALMS | | | 10-STORY CONDO | | | | | | 1)NOTE: NOTE #1, NO, PLEASE SEE NEW NOTE | | | PERTAINING TO THE NEW 2004 FBC AND | | | CHAPTER 13. | | | | | | ** PREVIOUS REVIEW ** | | | PLEASE KNOW, PLANS WERE SUBMITTED FOR | | | "PLAN REVIEW" ONLY AND WERE NOT | | | SUBMITTED FOR PERMIT BEFORE THE CODE | | | CHANGE OF OCT 1ST, 2005 TO THE NEW | | | 2004 FBC. | | | PLEASE SEE THAT ANY CHANGES WILL BE | | | NEEDED WHEN SUBMITTING FOR PERMIT. | | | | | | 2)NOTE: NOTE #2 OK. | | | | | | 3)NOTE: NOTE #3 OK, HOWEVER SEE NOTE | | | WITH RESPECT TO 110.26 AND ELECTRICAL | | | ROOMS AND SOME ELECTRICAL EQUIPMENT AND | | | REQ'D CLEARENCE. | | | | | | 4)NOTE: NOTE #4 OK | | | | | | 5)NOTE: NOTE #5 NO, PLEASE KNOW, PLANS | | | SHALL BE SPECIFIC TO THE CODE IN EFFECT | | | AND THE DESIGN IN WHICH THE BUILDING IS | | | BUILT. | | | PLEASE REFERENCE THE FOLLOWING CODES, AS | | | THESE CODES WERE NOT FOUND ON THE | | | ARCHITECTURAL PLANS. | | | 2002 NFPA-70, 2003 NFPA-101, 2002 | | | NFPA-110, 1999 NFPA-20. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE BE SURE PLANS ARE SPECIFIC TO | | | THE 2002 NEC WHICH IS CURRENTLY IN | | | EFFECT. | | | PLEASE KNOW: DEPENDING ON WHEN PLANS ARE | | | SUBMITTED FOR PERMIT, A CODE CHANGE TO | | | THE 2005 NEC SHOULD BE COMING ABOUT IN | | | MID 2006. | | | | | | 6)NOTE: NOTE #6 OK. | | | | | | 7)NOTE: NOTE #7NO, PLEASE SEE SOME | | | WERE SUBMITTED FOR GARAGE AND CORRIDORS, | | | HOWEVER STAIRWAYS COULD NOT BE LOCATED. | | | PLEASE ALSO KNOW, LEVELS UNDER EM POWER | | | SHALL BE PROVIDED. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE PROVIDE COMPLETE "PHOTO-METRICS" | | | FOR ALL CORRIDORS, STAIRWELLS AND EGRESS | | | AREAS PER 2003 NFPA-101 7.8 AND 7.9. | | | PLEASE SEE A MIN OF 10 FT CANDLES IS NOW | | | REQUIRED FOR STAIR TOWERS UNDER NORMAL | | | EGRESS CONDITIONS. | | | | | | 8)NOTE: NOTE #8 OK, PLEASE SEE NEW | | | COMMENTS FOR GEN RM. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE BE SURE THERE ARE EMERGENCY | | | BATTERY BACK UP TYPE FIXTURES LOCATED IN | | | ALL ELECTRICAL ROOMS, ELEVATOR EQUIPMENT | | | ROOMS, FIRE PUMP, GENERATOR, AND FIRE | | | COMMAND ROOM. | | | PLEASE KNOW, SOME OF THESE ARE ALREADY | | | SHOWN ON PLANS, HOWEVER SOME AREAS MAY | | | BE REDLINED FOR THESE. | | | NFPA-101 7.8,7.9, NEC 700.16 ETC. | | | | | | 8)NOTE: NOTE #8 ( # MISPRINT)NO, PLEASE | | | SEE STAIRS INDICATE A BATTERY ABCK UP AT | | | EVERY OTHER LEVEL WHICH IS OK. PLEASE | | | SEE CORRIDORS AND GARAGES EGRESS PATHS | | | ARE TO CONTAIN A MININUM OF SOME SORT OF | | | BATTERY BACK UP TYPE FIXTURE TO PROVIDE | | | A MINIMAL AMOUNT OF LIGHT TO ACCESS THE | | | EGRESS TOWERS . LOCATIONS CAN BE GONE | | | OVER IN A MEETING WHICH IS MOST CERTAIN | | | FORTH COMING AFTER ALL REVIEWS ARE | | | COMPLETED. PLEASE SEE COMMENT FOR | | | FIXTURES AS THIS COMMENT MAY ALREADY BE | | | ADDRESSED HOWEVER IS UNCLEAR DUE TO SOME | | | FIXTURES SHOWN ON PLANS WHICH ARE NOT | | | LISTED ON FIXTURES SCHEDULE. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE THAT EGRESS CORRIDORS, AND | | | STAIR TOWERS WILL BE REQUIRED TO CONTAIN | | | A MIN BATTERY BACK UP TYPE OF FIXTURE | | | FOR EMERGENCY EGRESS OF 1 FT CANDLE. | | | 7.9 LS 101 THE TRIPPING OF A SINGLE | | | SWITCH OR BREAKER SHALL NOT LEAVE ANY | | | ONE AREA IN TOTAL DARKNESS. | | | | | | 9)NOTE: NOTE #9 OK. | | | | | | 10)NOTE: NOTE #10 OK. | | | | | | 11)NOTE: NOTE #11 OK. | | | | | | 12)NOTE:NOTE #12 NO, THIS NOTE COULD | | | NOT BE LOCATED, ONLY A NOTE WITH | | | REFERENCE TO POOL PERMIT. | | | PLEASE PLACE NOTE ON PLANS FOR ALL MIN | | | CLEARENCES 10' FOR 120V W/ GFI | | | PROTECTION AND 5' FOR LV. 680.22,411.4. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE NOTE ON PLANS THE MIN | | | CLEARNECES FOR LT FIXTURES IN PROXIMITY | | | OF POOL AND WATER FEATURES WATER'S EDGE. | | | PLEASE SEE A MINOF 10' IS REQUIRED FOR | | | FIXTURES OVER 30V.411.4 | | | PLEASE SEE 680.22 FOR A MIN OF 5' FROM | | | WATER'S EDGE WITH EXCEPTIONS. | | | | | | 13)NOTE: NOTE #13 OK. | | | | | | 14)NOTE: NOTE #14 OK, REMOVED FROM | | | PLANS. SEE NEW NOTES. | | | | | | 15)NOTE: NOTE #17 OK. MOST ALL FLR | | | SUBMITTED. PLEASE SEE HOWEVER THERE | | | STILL APPEARS TO BE A MISSING SHEET FOR | | | INTERMEDIATE ROOF LAYOUT EAST/ SOUTHEAST | | | LAYOUT. | | | | | | 16)NOTE: NOTE #16 NO, COULD NOT LOCATE | | | ANY NOTES ON ANY OF THE ROOF TOP PLANS. | | | NOTE MUST BE ON PLANS. | | | PLEASE KNOW, THERE ARE MANY "SYSTEMS" | | | ON THE MARKET BEING PROPOSED AND | | | ADVERISED AS BEING ACCEPTABLE AND | | | MEETING CODE ETC. PLEASE KNOW, ONLY | | | SYSTEMS CONTAINING THE RECOGNIZED UL | | | LISTINGS/CERTIFICATIONS WHICH ARE UNDER | | | NFPA-780 WILL BE PERMITTED TO BE | | | INSTALLED. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE PROVIDE NOTE ON ROOF-TOP | | | PLANS WHICH WILL STATE THAT ANY | | | LIGHTNING PROTECTION SYSTEMS MUST BE IN | | | COMPLIANCE WITH NFPA-780. (OR WORDS TO | | | THAT AFFECT). | | | | | | 17)NOTE: NOTE #17 OK. | | | | | | 18)NOTE: NOTE #18 NO, PLEASE SEE THERE | | | ARE AREAS OF PLANS WHICH ARE STILL | | | MISSING CIRCUITING AND SOME AREAS WHERE | | | FIXTURES SEEM TO BE "LIGHT" ALTHOUGH AND | | | CIRCUITING LINE IS SHOWN TO THESE | | | FIXTURES. | | | PLEASE SEE REDLINED PLANS. | | | | | | **PREVIOUS NOTE ** | | | PLEASE SEE NO CIRCUITING SHOWN FOR SOME | | | "HOUSE AREAS". PLEASE SEE REDLINED PLANS | | | ON 2.32, STORAGE RM ETC. | | | | | | 19)NOTE: NOTE #19 NO, PLEASE SEE SOME | | | ROOMS WHERE RECEPT CIRCUITS FEED MORE | | | THAN ONE ROOM. | | | PLEASE SEE REDLINED PLANS. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE 680.23 AND 680.24 WHICH | | | REQUIRES "NO OTHER" LIGHTING OR RECEPTS | | | ON ELEVATOR MACHINE RMS CIRUITS OR ELEV | | | PITS. PLEASE SEE 2.34,2.35 AND ANY OTHER | | | ARES WHICH MAY BE FED FROM ANY OF THESE | | | CIRCUITS. | | | | | | 20)NOTE: NOTE 320 OK, HOWEVER SEE SOME | | | NEW NOTES FOR CIRCUITING NOW THAT | | | CIRCUITS ARE SHOWN. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SHOW CIRCUITING FOR ALL UNITS AND | | | CORRELATE WITH THE PANEL SCHEDULES | | | SUBMITTED. PLEASE KNOW, CODE COMPLIANCE | | | FOR SOME ITEMS CAN NOT BE DONE AT THIS | | | TIME. | | | | | | 21)NOTE: NOTE #21 NO/YES, PLEASE SEE | | | MOST WERE ADDRESSED, HOWEVER PLEASE SEE | | | NOW UNTI B2 INDICATES 60A OCP FOR 5KW | | | UNIT. | | | PLEASE ALSO CORRELATE ALL KW HEAT STRIPS | | | WITH MECHANICAL PLANS AND ADJUST LOADS | | | AS ALL UNITS ON "M" SHEETS ARE SHOWN W/ | | | 5KW HEAT. | | | | | | ** PREVIOSU NOTE ** | | | PLEASE SEE 424.3B FOR MIN OCP FOR AHU'S | | | AND HEAT. | | | PLEASE SEE MANY PANEL SCHEDULES INDICATE | | | LOADS AT 11KW ETC @65%?? PLEASE CLARIFY | | | AS 11KW SI SHOWN AS THE DERATED LOAD. | | | PLEASE SEE IF 11KW IS THE DE-REATED | | | LOAD, THEN THE ACTUAL KW RATING FOR AHU | | | WOULD BE ALMOST 15KW?? | | | | | | | | | 22)NOTE: NOTE #22 OK. | | | | | | 23)NOTE: NOTE #23 OK. | | | | | | 24)NOTE: NOTE #24 OK,HOWEVER SEE NOTES. | | | | | | 25)NOTE: NOTE #25 OK. | | | | | | 26)NOTE: NOTE #26 NO, PLEASE SEE PLANS | | | STILL MENTIONS TO USE 310.15B, HOWEVER | | | PLEASE KNOW, "B6" CAN NOT BE SUED IN | | | DERATING. | | | PLEASE ALSO SEE NEW NOTE MENTIONS THE | | | CONTRACTOR MAY SUBSTITUTE W/ ALUM. | | | PLEASE KNOW, THE CONTRACTOR MAY NOT MAKE | | | THIS DECISION OR REVISION. PLEASE KNOW | | | ONLY THE DESIGNER AND ENGINEER OF RECORD | | | CAN MAKE ANY CHANGES TO CONDUCTORS WHICH | | | MUST BE PROPOSED IN A REVISION, SIGNED | | | DATED, SEALED AND SUBMITTED FOR REVIEW | | | BEFORE CHANGES CAN BE MADE ON THE | | | JOBSITE. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE NOTE #8, ON PANEL SCHEDULE | | | NOTES. PLEASE SEE 310.15B6, WHICH DOES | | | NOTES INLCUDE 120/208V SYSTEMS.THIS IS | | | FOR INFORMATION ONLY. | | | | | | 27)NOTE: NOTE #27 OK. | | | | | | 28)NOTE: NOTE #28 OK. | | | | | | 29)NOTE: NOTE #29 OK, HOWEVER SEE NOTES | | | FOR 210.52/210.52C1 REDLINED | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE UNIT A-8 FOR MISSING RECEPT | | | PER 210.52. PLEASE BE SURE TO CHECK | | | REDLINED PLANS FOR ANY OTHER POSSIBLE | | | LOCATIONS WHICH MAY REQUIRE A RECEPT. | | | | | | 30)NOTE: NOTE #30 OK. | | | | | | 31)NOTE: NOTE #31 OK. | | | | | | 32)NOTE: NOTE #32 OK. | | | | | | 33)NOTE: NOTE #33 OK, HOWEVER SEE NEW | | | NOTES FOR CORRELATION OF NOTES AND | | | RISER. | | | | | | 34)NOTE: NOTE #34 OK, HOWEVER SEE NEW | | | NOTES DUE TO CHANGES IN RISER/PLANS. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SEE COMPLETE RISER DIAGRAM WITH | | | LABELING OF FEEDERS FOR FEEDER SCHEDULE | | | AND CORRELATING ALL NUMERCICAL | | | IDENTIFICATION. | | | | | | 35)NOTE: NOTE #35 OK. | | | | | | 36)NOTE: NOTE #36 NO, NO SUBMITTIALS | | | WERE SUBMITTED FOR REVIEW. PLEAS EKNOW, | | | SPECS FOR THESE ITEMS MUST BE SUBMITTED | | | TO REVIEW FOR CODE COMPLIANCE. PLEASE | | | SEE THERE ARE MANY ITEMS IN NFPA-20 | | | CHAPTER 6 AND NFPA-110 WHICH CAN NOT BE | | | VERIFIED AT THIS TIME AND FURTHER | | | COMMENTS MAY ARISE AS CODE COMPLIANCE | | | CAN NOT BE DONE AT THIS TIME. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SUBMIT ALL INFORMATION | | | FOR FIRE PUMP AND FIRE PUMP CONTROLLER. | | | PLEASE ALSO PROVIDE MANUFACTURES | | | SPECS/CUT SHEETS FOR ABOVE. | | | | | | 37)NOTE: NOTE #37 NO, PLEASE SEE NO | | | SPECS WERE SUBMITTED. PLEASE ALSO SEE | | | RISER INDICATES THE 4-POLE ATS, HOWEVER | | | NOTES MENITON THIS IS NOT A SEPARATELY | | | DERIVED GENERATOR? PLEASE SEE AS A | | | 4-POLE ATS, THE GEN IS "SEP DERIVED" AND | | | GROUNDING SHALL BE DONE ACCORDINGLY. | | | PLEASE SEE MISSING BONDING AT FIRST | | | MENAS OF DISCONNECT , EQUIPMENT GROUNDD | | | ETC. PLEASE SEE NFPA-110 6.2.15*. PLEASE | | | VERIFY WITH MANUFACTURE OF EQUIPMENT. | | | PLEASE SEE NEW NOTES FOR ATS AND MAIN. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE SUBMIT ALL INFORMATION | | | FOR GENERATOR/ ATS. PLEASE SUBMIT THE | | | SPECS/CUT FROM MANUFACTURE. | | | PLEASE VERIFY OF THE ATS WILL BE A | | | 4-POLE SWITCH. | | | PLEASE SEE 700.7D AND IF YOU HAVE THE | | | HANDBOOK, SEE EXPLANATION OF ARTICLE. | | | I HAVE ATTACHED BOTH, JUST IN CASE. | | | | | | (D) GROUND FAULT. TO INDICATE A GROUND | | | FAULT IN SOLIDLY GROUNDED WYE | | | EMERGENCY SYSTEMS OF MORE THAN 150 VOLTS | | | TO GROUND AND CIRCUIT-PROTECTIVE | | | DEVICES RATED 1000 AMPERES OR MORE. THE | | | SENSOR FOR THE GROUND-FAULT SIGNAL | | | DEVICES SHALL BE LOCATED AT, OR AHEAD | | | OF, THE MAIN SYSTEM DISCONNECTING | | | MEANS FOR THE EMERGENCY SOURCE, AND THE | | | MAXIMUM SETTING OF THE SIGNAL | | | DEVICES SHALL BE FOR A GROUND-FAULT | | | CURRENT OF 1200 AMPERES. INSTRUCTIONS | | | ON THE COURSE OF ACTION TO BE TAKEN IN | | | EVENT OF INDICATED GROUND FAULT | | | SHALL BE LOCATED AT OR NEAR THE SENSOR | | | LOCATION. | | | | | | ALTHOUGH 700.26 INDICATES THAT | | | GROUND-FAULT PROTECTION OF EQUIPMENT IS | | | NOT | | | REQUIRED ON THE ALTERNATE SOURCE FOR | | | EMERGENCY SYSTEMS, GROUND FAULTS CAN | | | OCCUR ON SUCH SYSTEMS, AND THEY CAN | | | RESULT IN EQUIPMENT BURNDOWN. BECAUSE | | | OF THE EMERGENCY NATURE OF SUCH SYSTEMS, | | | AUTOMATIC DISCONNECT IN THE EVENT | | | OF A GROUND FAULT IS INAPPROPRIATE. | | | DETECTION OF SUCH A FAULT, HOWEVER, IS | | | DESIRABLE SO THAT THE CONDITION CAN BE | | | CORRECTED. | | | IN MY READING AND THE INFORMATION FROM A | | | COULE OF MANUFACURES OF ATS SWITCHES, A | | | 4-POLE ATS IS REQUIRED. PLEASE RESERCH | | | THE INFORMATION AND ADJUST. | | | | | | 38)NOTE: NOTE #38, OK.P | | | | | | 39)NOTE: NOTE #39 YES/ NO, PLEASE NOW | | | SEE TWO SETS OF DRAWING KEYNOTES, WHICH | | | AS NOTED IN ONE SET MOST DO NOT | | | CORRELATE WITH RISER DIAGRAM. PLEASE SEE | | | SOME COMMENTS FOR OTHER. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE COMPLETE DRAWING KEYNOTES TO | | | CORRELATE WITH PLANS. | | | | | | 40)NOTE:NOTE #40 OK, PLEASE SEE SEC'S | | | ARE NOW SHOWN AS UNDER GROUND. SEE NEW | | | NOTES FOR ROOM LAYOUT. | | | | | | **PREVIOUS NOTE **PLEASE VERIFY RISER | | | DIAGRAM SEC'S AND CONDUITS FOR FIRE | | | PUMP, RISER APPEARS TO SHOW FEED | | | OVERHEAD? | | | PLEASE SEE NFPA-20, 70 WHICH REQUIRES | | | COMPLETE ENCASEMENT OF FEEDS. | | | | | | 41)NOTE: NOTE #41 OK, PLEASE SEE MORE | | | INFORMATION ON PLANS WAS COMPLETED AND | | | SUBMITTED FOR REVIEW, PLEASE SEE ANY NEW | | | COMMENTS FOR REVIEW. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE COMPLETE ALL PANELS, WITH | | | INFORMATION ON PANELS, SIZE, MLO, | | | MCB ETC. | | | PLEASE COMPLETE LOAD CALCULATIONS FOR | | | REVIEW. | | | | | | 42)NOTE: NOTE #42 ?? NO?, PLEASE SEE | | | PLANS NOTE WIND LOAD PRESSURES TO MEET | | | 140 MPH, HOWEVER IT IS NOT KNOWN WHERE | | | THESE ARE FOR REVIEW. | | | | | | ** PREVIOUS NOTE ** | | | PLEASE PROVIDE WIND LOAD | | | CALCUALTIONS FOR BLDG REVIEW OF ANY SITE | | | LIGHTING/ROOF TOP LT POLES. | | | | | | ************************************** | | | ************************************* | | | ********* NEW NOTES ***************** | | | | | | | | | 43) NOTE: PLEASE KNOW, A FULL AND | | | COMPLETE TYPE WRITTEN RESPONSE FROM THE | | | DESIGN TEAM WHICH RESPONSES TO THE PLANS | | | REVIEWERS COMMENTS WILL HELP IN | | | EXPEDITING THE PLAN REVIEW PROCESS. THIS | | | NUMERICAL REPONSE WILL HELP TO | | | ALLEAVIATE ANY BACK AND FORTH QUESTIONS | | | OR CONFUSION. | | | NO, RESPONSE LETTERS WERE SUBMITTED WHEN | | | PLANS WERE BROUGHT BACK FOR REVIEW. | | | | | | 44) NOTE: PLEASE SEE ALL PLANS, SHEETS, | | | DOCUMENTS BEING SIGNED, DATED OR SEALED | | | BY A LICENSED PE, SHALL ONLY CONTAIN A | | | SEAL WITH THE WORDING OF "LICENSE". | | | PLEASE SEE A RULING BY THE FLORIDA BOARD | | | OF PROFESSINAL ENGINEERS DATED IN | | | FEBUARY "04", RULED IN 61G15-23.001, | | | THAT ALL SEALS SHALL NO LONGER USE | | | "CERTIFICATE" IN SAID SEAL. PLEAS KNOW, | | | AN EXTENSION WAS GIVEN TO THE DATE OF | | | DEC. 31ST , 2005.PLEASE SEE THIS IS | | | NOT A COMMENT FOR STEVEN FELLER AS SEAL | | | IS CORRECT. PLEASE SEE OTHER DOCUMENTS | | | SUBMITTED DO CONTAIN THE SEAL WHICH IS | | | NO LONGER ACCEPTABLE. | | | PLEASE SEE DE LOS REYES ENG.AND ANY | | | OTHERS WHICH MAY STILL BE UTILIZING OLD | | | SEAL. | | | PLEASE KNOW, THIS COMMENT IS MADE FOR | | | ALL PLANS AND DOCUMENTS WHETHER OR NOT | | | COMMENT IS MADE BY OTHER REVIEWER(S). | | | | | | 45) NOTE: PLEASE SEE FBC 2004 CHAPTER | | | 13, 13-415.1.ABC.1.1, &.2, &.3. | | | PLEASE SHOW AND PROVIDE DEVICES, | | | CONTROLS ETC FOR ALL AREAS NOW REQUIRED | | | TO CONTAIN ENERGY CONSERVATION MEASURES. | | | PLEASE SEE 13-413.1ABC.1 AND PROVIDE | | | NOTES/WORST CASE FOR VOLTAGE DROP. | | | PLEASE SEE 13-415.1.ABC.2 FOR AREA | | | LIGHTING. | | | PLEASE SEE THESE CHANGES ARE COMPLETELY | | | DIFFERENT FORM THE 2001 FBC. | | | THESE CHANGES BECAME FEDERALLY MANDATED | | | FOR ALL STATES TO COMPLY IN THE NEXT | | | CODE CYCLE/CHANGE. THIS FEDERAL MANDATE | | | WAS PASSED JULY 2004 | | | PLEASE SEE NOTE #1 FROM PREVIOUS REVIE | | | MENTIONED TO SEE ALL 2004 FBC FOR ALL | | | CHANGES IN DESIGN AS PROJECT WAS NOT | | | SUBMITTED FOR PERMIT UNDER THE 2001 FBC. | | | | | | 46) NOTE: PLEASE SEE NFPA-110,7.3.3 FOR | | | MIN LIGHTING LEVELS IN GENERATOR ROOM TO | | | BE 30FT CANDLES. PLEASE SEE | | | PHOTO-METRICS FOR THIS AREA SHOULD BE | | | SHOWN. | | | | | | 47) NOTE: | | | A) PLEASE SEE NFPA-110, 7.9.3.1, | | | GALVANIZED LINES SHALL NOT BE USED FOR | | | PIPNG TO GENERATOR. THIS IS NOTED FOR | | | PLUMBING/ ENGINEERING AS SOME LOCATIONS | | | IN THE JURISDICTION HAS INSTALLED THESE | | | AND HAVE HAD TO CHANGE TYPES OF PIPING. | | | PLEASE KNOW THIS IS A NOTE AT THIS TIME | | | FOR INFORMATIONAL PURPOSE ONLY. | | | B) PLEASE ALSO SEE NFPA-20, NFPA-110 , | | | NOTES AND SPECS FOR FUEL TYPE AND | | | STORAGE WAS NOTE SUBMITTED, PLEASE SEE | | | MIN RUNNING TIME CAN NOT BE VERIFIED. | | | PLEASE SEE 6-6.2 FOR A MIN OF 8 HRS | | | @100% ALONG WITH ALL OTHER MIN REQUIRED | | | LIFE SAFETY LOADS. | | | THE AMOUNT OF FUEL, AND GPH SHOULD BE | | | NOTED ON PLANS. ONE OF THE DRAWING KEY | | | NOTES MENTIONS 500 GAL TANK?TBD. | | | | | | 48) NOTE: PLEASE SEE THERE ARE FIXTURES | | | ON PLANS WHICH ARE NOTE ON FIXTURE | | | SCHEDULE? R-1, R-2, W-1,, | | | | | | 49) NOTE: PLEASE SEE SOME FIXTURES ON | | | PLANS DO NOT CONTAIN FIXTURE | | | DESIGNATIONS. | | | "REDLINED ON PLANS" | | | | | | 50) NOTE: PLEASE SEE LAYOUT ON MEZZ LVEL | | | FOR DOM PUMP RM AND FIRE PUMP RM. PLEASE | | | SEE THESE SEEM TO BE MISSING | | | WALLS/SEPARATION FROM GARAGE/RAMP | | | AREAS.? 2.05 | | | 215.5 | | | | | | 51) NOTE:PLEASE INDICATE IF GHB | | | CONTAINS "FEED-THRU LUGS" OR DOES THIS | | | PANEL CONTAIN OCP TO FEED "GHB2"? | | | 215.5 | | | | | | 52) NOTE: PLEASE SEE "LA", DOES THIS | | | PANEL ALSO CONTAIN "FEED-THRU LUGS" OR | | | DOES IT CONTAIN OCP TO FEED"LA2"? | | | IF SO, PLEASE INDICATE THE OCP AND AWG | | | SIZES. | | | 215.5 | | | | | | 53) NOTE: PLEASE SEE CORRELATION FOR | | | "KEYNOTES" AS RISER CONTAINS #11,10, | | | 12,13 ETC WHICH DO NOT MATCH AS NOTED | | | ABOVE. | | | | | | 54) NOTE: PLEASE SEE PANELS "HB", LB", | | | AND TRANSFORMER, AS LAYOUT DOES NOT SEEM | | | TO MEET 110.26 | | | 4.01 | | | | | | 55) NOTE: PLEASE SEE PREVIOUS NOTE WITH | | | RESPECT TO THE ATS AND 4-POLE, | | | SEPARATELY DERIVED SYSTEM. | | | PLEASE SEE 250.6,250.24B AND 250.122 FOR | | | SIZING ANY EQUIPMENT GORUNDING | | | CONDUCTORS. | | | | | | 56) NOTE: PLEASE SEE DINING AREAS IN | | | A4A, A5, C1 WHICH SHOW RECEPT ON LIVING | | | RM CIRCUIT. | | | 210.52B1 | | | PLEASE VERIFY ALL DINING AREAS AS SHOWN | | | AS IDENTIFY AS NEEDED FOR AREA | | | DESIGNATIONS. MOST ARE OK. | | | SEE REDLINED. | | | | | | 57) NOTE: PLEASE SEE AREA IN UNIT "B3" | | | WHICH SEEMS TO SHOW COUNTERSPACE AND | | | WALL AREA ? | | | PLEASE SEE 210.52 IF WALL , AND 210.52C1 | | | IF COUNTER SPACE. (GFI)210.8A6 | | | | | | 58) NOTE: PLEASE SEE LOAD SUMMARY FOR | | | FIRE PUMP ON RISER WHICH CONTAINS AN "*" | | | ASTERISK FOR NOTE OF MAGNETIC ONLY 6X | | | LR, HOWEVER THIS "*" IS NOT ABOVE FOR | | | FIRE PUMP. SEE REDLINES THIS IS NOTED AS | | | PLANS ARE COMING BACK FOR COMMENTS. | | | | | | 59) NOTE: PLEASE SEE EM MAIN SHOLD NOT | | | BE LOCATED DIRECTLY NEXT TO EXISTING | | | MAIN DISTRIBTUTION EQUIPMENT. THIS MAY | | | BE IN THE SAME ROOM, HOWEVER SHOULD BE | | | LOCATED ON THE OTHER SIDE OF ROOM. | | | PLEASE SEE IF THE ATS IS 4-POLE AND | | | SERVICE ENTRANCE RATED, THE MSBE WOULD | | | NOT BE NEEDED, THE EDPH COULD CONTAIN A | | | MCB AND WOULD MEET THE NEC. | | | PLEASE KNOW, IN EITHER CASE A MEANS OF | | | DISCONNECT ON THE LOAD OR LINE SIDE OF | | | ATS FOR FEED COMING FROM GENERARATOR | | | WOULD BE NEEDED GROUPED IN CLOSE | | | PROXIMITY TO THE ATS, EM MAIN. PLEASE | | | CALL TO GO OVER. SOME ITEMS ARE NOT | | | KNOWN AT THIS TIME. | | | | | | 60) NOTE: PLEASE SEE RISER AND OTHER | | | PANELS INDICATE PANELS "HP AND LP" , | | | HOWEVER NEITHER OF THESE ARE SUBMITTED | | | TO VERIFY AT THIS TIME. PLEASE SHOW. | | | 215.5 | | | | | | 61) NOTE: PLEASE PROVIDE ELEVATION FOR | | | EPSS. PLEASE SEENFPA-110 7.2.3*,THE | | | ELEVATION OF THE EPSS SHALL BE 6" ABOVE | | | THE "SLOSH" PREDICATION LEVELS. | | | "SEA, LAKE, OVERLAND SURGES BY | | | HURRICANCES. CHARTS BASED ON SURGES FROM | | | A CAT 4 STORM. | | | | | | 62) NOTE: WHEN AND BEFORE RESUBMITTING | | | PLANS, PLEASE COMPLETELY REMOVE ANY AND | | | ALL OLD/VOIDED SHEETS FROM SETS. PLEASE | | | ONLY INSERT ONLY NEW REVISED SHEETS INTO | | | COMPLETE SETS FOR REVIEW AND STMAPING. | | | PLEASE KNOW, THIS WAS DONE ON THIS | | | SUBMITTAL. | | | | | | ** PLEASE SEE LOCATIONS ON PLANS IN | | | WHICH MANY OF THE ABOVE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS OF COMMENTS. | | | | | | ** PLEASE BE AWARE OF ANY COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT COMPLETED PLANS FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | ** | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | 2006-05-04 00:00:00 | ROLLS OF MEP IN ELEC FOR REVIEW TO | | | COMMENCE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-11-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2005-11-29 |
Time |
13:48 |
Rev Time |
24.00 |
| Received By |
dpalmer |
Date |
2005-11-22 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2005-11-28 00:00:00 | *** UNSAT *** | | | | | | CITY PALMS | | | 10-STORY CONDO | | | | | | 1)NOTE: PLEASE KNOW, PLANS WERE | | | SUBMITTED FOR "PLAN REVIEW" ONLY AND | | | WERE NOT SUBMITTED FOR PERMIT BEFORE THE | | | CODE CHANGE OF OCT 1ST, 2005 TO THE NEW | | | 2004 FBC. | | | PLEASE SEE THAT ANY CHANGES WILL BE | | | NEEDED WHEN SUBMITTING FOR PERMIT. | | | | | | 2)NOTE: PLEASE BE SURE ALL PLANS | | | SUBMITTED FOR PERMITTING ARE SIGNED, | | | DATED AND SEALED BY THE ENGINEER OF | | | RECORD. | | | FS 471.025 | | | | | | 3)NOTE: PLEASE SEE 110.26 FOR MEANS OF | | | EGRESS FROM MAIN ELECTRICAL ROOM. | | | PLEASE SEE THIS HAD BEEN GONE OVER IN A | | | MEETING PRE-SUBMITTAL OF PLANS AND | | | DESIGN FOR DOOR AND STAIR LOCATIONS WERE | | | DICUSSED FOR A CHANGE. | | | PLEASE KNOW, THAT IT IS THE UNDER | | | STANDING OF THIS OFFICE THAT THE DOOR | | | WOULD INCREASE TO A 6' OPENING AND ONLY | | | ONE MEANS OF EGRESS WOULD BE PROVIDED | | | AND STAIRS WOULD BE REMOVED? | | | PLEASE VERIFY THIS AND ADJSUT PLANS FOR | | | THESE CHANGES. | | | THE STAIRS AS A MEANS OF EGRESS INSIDE | | | THE MAIN ELECTRICAL ROOM WOULD PROPOSE A | | | TRIPPING HAZARD IN A SITUATION OF | | | SOMEONE BEING BLINDED OR HAVING TO EXIT | | | THE ROOM IN AN EMERGENCY SITUATION. | | | PLEASE INCLUDE "NOTES" ON SHEET FOR MAIN | | | ELECTRICAL ROOM FOR ALL MIN CLEARNECES | | | OER 110.26, PANIC HARDWARE FOR DOORS | | | ETC. | | | PLEASE ALSO SEE MIN CLEARENCE FOR OTHER | | | ELECTRICAL ROOMS SHOWN ON ROOM LAYOUT | | | PLAN. | | | | | | 4)NOTE: PLEASE SEE PLANS CALL FOR | | | BLUIDING TO BE LOCATED AT 480 HIBISCUS, | | | HOWEVER OUR SYSTEMWITH PCN # PROVIDED | | | INCIDICATES "430". PLEASE CORRELATE AND | | | ADJUST PLANS/APPLICATION. ETC. | | | | | | 5)NOTE: PLEASE BE SURE PLANS ARE | | | SPECIFIC TO THE 2002 NEC WHICH IS | | | CURRENTLY IN EFFECT. | | | PLEASE KNOW: DEPENDING ON WHEN PLANS ARE | | | SUBMITTED FOR PERMIT, A CODE CHAMGE TO | | | THE 2005 NEC SHOULD BE COMING ABOUT IN | | | MID 2006. | | | | | | 6)NOTE: PLEASE SEE 1.01 AND ADDITIONAL | | | SHEETS WHICH REFERENCE ABCK TO 3.02 FOR | | | ELECTRICLA ROOM LAYOUTS, HOWEVER 3.02 | | | DOES NOT SHOW ROOM LAYOUTS. | | | PLEASE CORRELATE. | | | | | | 7)NOTE: PLEASE PROVIDE COMPLETE | | | "PHOTOMETRICS" FOR ALL CORRIDORS, | | | STAIRWELLS AND EGRESS AREAS PER 2003 | | | NFPA-101 7.8 AND 7.9. | | | PLEASE SEE A MIN OF 10 FT CANDLES IS NOW | | | REQUIRED FOR STAIR TOWERS UNDER NORMAL | | | EGRESS CONDITIONS. | | | | | | 8)NOTE: PLEASE BE SURE THERE ARE | | | EMERGENCY BATTERY BACK UP TYPE FIXTURES | | | LOCATED IN ALL ELECTRICAL ROOMS, | | | ELEVATOR EQUIPMENT ROOMS, FIRE PUMP, | | | GENERATOR, AND FIRE COMMAND ROOM. | | | PLEASE KNOW, SOME OF THESE ARE ALREADY | | | SHOWN ON PLANS, HOWEVER SOME AREAS MAY | | | BE REDLINED FOR THESE. | | | NFPA-101 7.8,7.9, NEC 700.16 ETC. | | | | | | 8)NOTE: PLEASE SEE THAT EGRESS | | | CORRIDORS, AND STAIR TOWERS WILL BE | | | REQUIRED TO CONTAIN A MIN BATTERY BACK | | | UP TYPE OF FIXTURE FOR EMERGENCY EGRESS | | | OF 1 FT CANDLE. | | | 7.9 LS 101 | | | THE TRIPPING OF A SINGLE SWITCH OR | | | BREAKER SHALL NOT LEAVE ANY ONE AREA IN | | | TOTAL DARKNESS. | | | | | | 9)NOTE: PLEASE SEE WOMENS AND MENS | | | RESTRMS IN COMMON AREAS CONTAINING | | | RECEPTS LOCATED IN CLOSE PROXIMITY OF | | | LAVATORYS. PLEASE BE SURE TO INDICATE | | | GFI PROTECTIONS FOR THESE. | | | 210.8B1 | | | | | | 10)NOTE: PLEASE SEE "CLUB RM" AND ALL | | | RECEPTSWITHIN 6' OF SINKS SAHLL BE | | | INDICATED AS GFI/GFI PROTECTED. | | | 210.8B | | | | | | 11)NOTE: PLEASE SEE RETAIL SPACE #14, | | | WHICH INDICATES A TRANSFORMER AND PANEL | | | AS "FUTURE", HOWEVER PLEASE SEE THERE IS | | | AN ADDITIONAL PANEL SHOWN BUT NOT CLEAR | | | FOR USE ETC? | | | 215.5 | | | | | | 12)NOTE: PLEASE NOTE ON PLANS THE MIN | | | CLEARNECES FOR LT FIXTURES IN PROXIMITY | | | OF POOL AND WATER FEATURES WATER'S EDGE. | | | PLEASE SEE A MINOF 10' IS REQUIRED FOR | | | FIXTURES OVER 30V. | | | PLEASE SEE 680.22 FOR A MIN OF 5' FROM | | | WATER'S EDGE WITH EXCEPTIONS. | | | | | | 13)NOTE: PLEASE SEE POSSIBLE NOTES FROM | | | REVIEWS FROM FIRE, BLDGMECH ETC, WITH | | | RESPECT TO THE LOCATION OF GENERATOR | | | INTAKE AND EXHAUST. THESE SEEMS TO BE | | | LOCATED IMEDIATELY ADJACENT TO THE PUBLE | | | RIGHT OF WAY/SIDE WALK. | | | PLEASE KNOW, THIS IS ONLY A COMMENT FOR | | | ELECTRICAL REVIEW , HOWEVER MAY CHANGE | | | ELECTRICAL LAYOUT?? | | | | | | 14)NOTE: PLEASE SEE PANELS "HP AND "LP". | | | TRANSFORMER LOCATED AT ELEC RM ON 2.17. | | | PLEASE SEE MIN CLEARENCES PER 110.26 | | | | | | 15)NOTE: PLEASE SEE SHEETS 2.21 WHICH | | | STATES 6TH FLR, THEN 2.22GOES TO A | | | "TYPICAL PARTIAL FLR" AND THEN PLANS GO | | | BACK TO A 9TH FLR DETAIL ON 2.25? | | | PLEASE VEIRFY IF THESE ARE FLRS 7,8? | | | | | | 16)NOTE: PLEASE PROVIDE NOTE ON ROOF-TOP | | | PLANS WHICH WILL STATE THAT ANY | | | LIGHTNING PROTECTION SYSTEMS MUST BE IN | | | COMPLIANCE WITH NFPA-780. (OR WORDS TO | | | THAT AFFECT). | | | | | | 17)NOTE: PLEASE PROVIDE DISCONNECTS OR A | | | "TYPICAL DETAIL" FOR ROOF-TOP CU'S. | | | 440.11 | | | | | | 18)NOTE: PLEASE SEE NO CIRCUITING SHOWN | | | FOR SOME "HOUSE AREAS". PLEASE SEE | | | REDLINED PLANS ON 2.32, STORAGE RM ETC. | | | | | | 19)NOTE: PLEASE SEE 680.23 AND 680.24 | | | WHICH REQUIRES "NO OTHER" LIGHTING OR | | | RECEPTS ON ELEVATOR MACHINE RMS CIRUITS | | | OR ELEV PITS. PLEASE SEE 2.34,2.35 AND | | | ANY OTHER ARES WHICH MAY BE FED FROM ANY | | | OF THESE CIRCUITS. | | | | | | 20)NOTE: PLEASE SHOW CIRCUITING FOR ALL | | | UNITS AND CORRELATE WITH THE PANEL | | | SCHEDULES SUBMITTED. | | | PLEASE KNOW, CODE COMPLIANCE FOR SOME | | | ITEMS CAN NOT BE REVIEWED AT THIS TIME. | | | 215.5 | | | | | | 21)NOTE: PLEASE SEE 424.3B FOR MIN OCP | | | FOR AHU'S AND HEAT. | | | PLEASE SEE MANY PANEL SCHEDULES INDICATE | | | LOADS AT 11KW ETC @65%?? PLEASE CLARIFY | | | AS 11KW IS SHOWN AS THE DERATED LOAD. | | | PLEASE SEE IF 11KW IS THE DE-RATED LOAD, | | | THEN ACTUAL KW RATING FOR AHU WOULD BE | | | ALMOST 15KW?? | | | | | | 22)NOTE: PLEASE SEE WATER HEATERS SHOW | | | #8 AWG? PLEASE KNOW THIS IS ONLY A | | | COMMENT AS #8 IS OK, HOWEVER MAY NOT BE | | | REQUIRED. | | | PLEASE SEE THE FOLLOWING COMMENT** | | | | | | 23)NOTE: PLEASE VERIFYOCP SHOWN FOR | | | SOME WATER HEATERS AS 2POLE 30A AND SOME | | | AS 2-POLE 40A?? | | | PLEASE SEE 4.5KW IS THE SAME LOAD FOR | | | BOTH AT 208V. | | | PLEASE KNOW, THE CODE REQUIRES A MIN OCP | | | AT 125% (422.13) , HOWEVER THE CODE ALSO | | | LIMITS THE OCP AT 150%. 422.11. | | | PLEASE ADJUST OCP AND ANY AWG. | | | | | | 24)NOTE: PLEASE SEE PANEL SCHEDULE NOTES | | | LISTEDON EACH SHEET, HOWEVER THE NOTES | | | ARE NOT LABLED TO PANELS. | | | 215.5 | | | | | | 25)NOTE: PLEASE SEE MEDIA BOXES/PANELS | | | ARE SHOWN IN CLOSETS ABOVE STORAGE | | | SHELVES. | | | PLEASE KNOW, ANY RECEPT REQUIRED FOR ANY | | | TYPE OF PLUG-IN TRANSFORMER MAYNOT BE | | | AT THIS LOCATION ABOVE OR IN CLOSE | | | PROXIMITY TO ANY COMBUSTIBLES. | | | 110.26,240.24 | | | * NOTE:, ANY RECEPTS FOR ANY PLUG-IN | | | TYPE OF TRANSFORMERS, MAY BE LOCATED | | | ABOVE DOOR WAY.* | | | | | | 26)NOTE: PLEASE SEE NOTE #8, ON PANEL | | | SCHEDULE NOTES. PLEASE SEE 310.15B6, | | | WHICH DOES NOTES INLCUDE 120/208V | | | SYSTEMS.THIS IS FOR INFORMATION ONLY. | | | | | | 27)NOTE: PLEASE VERIFY PLANS INDICATE | | | BOTH A WASHER AND A DRYER, HOWEVER PLANS | | | SEEM TO INDICATE LOCATION FOR STACKABLE | | | UNITS ONLY.? | | | WILL ELECTRICAL BE INSTALLED FOR BOTH? | | | | | | 28)NOTE: PLEASE SEE UNIT A-6 AS IT SEEMS | | | WASHER/DRYER IS LOCATED ON KITCHEN | | | COUNTERSPACE? | | | | | | 29)NOTE: PLEASE SEE UNIT A-8 FOR MISSING | | | RECEPT PER 210.52. | | | PLEASE BE SURE TO CHECK REDLINED PLANS | | | FOR ANY OTHER POSSIBLE LOCATIONS WHICH | | | MAY REQUIRE A RECEPT. | | | | | | 30)NOTE: PLEASE PROVIDE NOTES FOR | | | PLACEMENT OF ALL SD'S PER 2002 NFPA-72 | | | 11.8.3 | | | | | | 31)NOTE: PLEASE SEE MANY UNITS DO NOT | | | INDICATE THE LV MEDIA BOXES AS SHOWN IN | | | OTHER UNITS? PLEASE SEE UNITS, B1, | | | B1B,B1F, B1E ETC. | | | PLEASE VERIFY | | | | | | 32)NOTE: PLEASE SEE UNIT B1F, WHICH | | | SEEMS TO INDICATE THE AN ENTIRE RECEPT | | | AS BEING SWITCHED? PLEASE KNOW, THE CODE | | | PERMITS A 1/2 SW RECEPT IF USING THE | | | RECEPT FOR 210.70, 210.52 OR PLEASE ADD | | | RECEPT TO MEET 210.52. | | | SEE REDLINED PLANS. | | | | | | 33)NOTE: PLEASE SEE MSBH ON 5.01 SHOWS | | | AS 2000A'S , YET 6.01 SHOWS 1200A WITH | | | 1000A MCB. | | | PLEASE CORRELATE: | | | | | | 34)NOTE: PLEASE SEE COMPLETE RISER | | | DIAGRAM WITH LABELING OF FEEDERS FOR | | | FEEDER SCHEDULE AND CORRELATING ALL | | | NUMERCICAL IDENTIFICATION. | | | | | | 35)NOTE: PLEASE PROVIDE THE FOLLOWING | | | FOR COMPLETETION OF GROUNDIOG ELECTRODE | | | SYSTEM. | | | PLEASE PROVIDE DETAIL FOR MAIN GROUNDING | | | ELECTRODE SYSTEM TO ALSO INCLUDE THE | | | REQUIRED FOOTER STEEL.250.50 | | | | | | PLEASE PROVIDE A GROUND RISER FOR | | | CONNECTION OF ALL OTHER SEPARATELY | | | DERIVED SYSTEMS/TRANSFORMER ATTACHMENTS | | | TO THE MAIN GROUNDIGN ELECTRODE SYSTEM. | | | 250.30 | | | PLEASE PROVIDE THIS ON THE RISER DIAGRAM | | | SHEET. | | | | | | 36)NOTE:PLEASE SUBMIT ALL INFORMATION | | | FOR FIRE PUMP AND FIRE PUMP CONTROLLER. | | | PLEASE ALSO PROVIDE MANUFACTURES | | | SPECS/CUT SHEETS FOR ABOVE. | | | | | | 37)NOTE: PLEASE SUBMIT ALL INFORMATION | | | FOR GENERATOR/ ATS. PLEASE SUBMIT THE | | | SPECS/CUT FROM MANUFACTURE. | | | PLEASE VERIFY OF THE ATS WILL BE A | | | 4-POLE SWITCH. | | | PLEASE SEE 700.7D AND IF YOU HAVE THE | | | HANDBOOK, SEE EXPLANATION OF ARTICLE. | | | I HAVE ATTACHED BOTH, JUST IN CASE. | | | | | | (D) GROUND FAULT. TO INDICATE A GROUND | | | FAULT IN SOLIDLY GROUNDED WYE | | | EMERGENCY SYSTEMS OF MORE THAN 150 VOLTS | | | TO GROUND AND CIRCUIT-PROTECTIVE | | | DEVICES RATED 1000 AMPERES OR MORE. THE | | | SENSOR FOR THE GROUND-FAULT SIGNAL | | | DEVICES SHALL BE LOCATED AT, OR AHEAD | | | OF, THE MAIN SYSTEM DISCONNECTING | | | MEANS FOR THE EMERGENCY SOURCE, AND THE | | | MAXIMUM SETTING OF THE SIGNAL | | | DEVICES SHALL BE FOR A GROUND-FAULT | | | CURRENT OF 1200 AMPERES. INSTRUCTIONS | | | ON THE COURSE OF ACTION TO BE TAKEN IN | | | EVENT OF INDICATED GROUND FAULT | | | SHALL BE LOCATED AT OR NEAR THE SENSOR | | | LOCATION. | | | | | | ALTHOUGH 700.26 INDICATES THAT | | | GROUND-FAULT PROTECTION OF EQUIPMENT IS | | | NOT | | | REQUIRED ON THE ALTERNATE SOURCE FOR | | | EMERGENCY SYSTEMS, GROUND FAULTS CAN | | | OCCUR ON SUCH SYSTEMS, AND THEY CAN | | | RESULT IN EQUIPMENT BURNDOWN. BECAUSE | | | OF THE EMERGENCY NATURE OF SUCH SYSTEMS, | | | AUTOMATIC DISCONNECT IN THE EVENT | | | OF A GROUND FAULT IS INAPPROPRIATE. | | | DETECTION OF SUCH A FAULT, HOWEVER, IS | | | DESIRABLE SO THAT THE CONDITION CAN BE | | | CORRECTED. | | | IN MY READING AND THE INFORMATION FROM A | | | COUPLE OF MANUFACTURES OF ATS SWITCHES, | | | A 4-POLE ATS IS REQUIRED. PLEASE RESERCH | | | THE INFORMATION AND ADJUST. | | | | | | 38)NOTE: PLEASE PROVIDE OCP LOCATED AT | | | GENERATOR. | | | THIS INFORMATION COULD NOT BE FOUND ON | | | PLANS/OR RISER DIAGRAM. | | | | | | 39)NOTE: PLEASE COMPLETE DRAWING | | | KEYNOTES TO CORRELATE WITH PLANS. | | | | | | 40)NOTE: PLEASE VERIFY RISER DIAGRAM | | | SEC'S AND CONDUITS FOR FIRE PUMP, RISER | | | APPEARS TO SHOW FEED OVERHEAD? | | | PLEASE SEE NFPA-20, 70 WHICH REQUIRES | | | COMPLETE ENCASEMENT OF FEEDS. | | | | | | 41)NOTE: PLEASE COMPLETE ALL PANELS, | | | WITH INFORMATION ON PANELS, SIZE, MLO, | | | MCB ETC. | | | PLEASE COMPLETE LOAD CALCULATIONS FOR | | | REVIEW. | | | | | | 42)NOTE: PLEASE PROVIDE WIND LOAD | | | CALCUALTIONS FOR BLDG REVIEW OF ANY SITE | | | LIGHTING/ROOF TOP LT POLES. | | | | | | ** PLEASE SEE LOCATIONS ON PLANS IN | | | WHICH MANY OF THE ABOVE ITEMS HAVE BEEN | | | REDLINED AT LOCATIONS OF COMMENTS. | | | | | | ** PLEASE BE AWARE OF ANY COMMENTS FROM | | | OTHER REVIEWER(S) WHICH MAY HAVE AN | | | AFFECT ON ELECTRICAL PLANS. | | | | | | ** PLEASE SUBMIT COMPLETED PLANS FOR | | | REVIEW. IF THERE ARE ANY QUESTIONS, | | | PLEASE DO NOT HESITATE IN CONTACTING | | | THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | 2005-11-17 00:00:00 | ONE ROLL IN ELECTRIC FOR REVIEW. | | | | | | | | | ************************************** | | | PLEASE KNOW, PLANS ONLY SUBMITTED FOR | | | "PLAN REVIEW" BEFORE OCT 1ST, 2005 AND | | | THE CODE CHANGE TO THE 2004 FBC. | | | | | | PLEASE KNOW THE EXSITNG "PROJECT" NUMBER | | | MAY CHANGE WHEN PLANS ARE SUBMITTED FOR | | | PERMIT AFTER OCT 1ST. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2006-06-06 |
Time |
|
Rev Time |
2.00 |
| Received By |
|
Date |
2006-06-06 |
Time |
|
Sent To |
|
|
| Notes |
| 2006-06-06 00:00:00 | PROJECT EXEMPT FROM SFWMD ERP DUE TO | | | ACREAGE. | | | | | | SEPERATE ROW PERMIT WITH MOT WILL BE | | | REQUIRED.CONTACT WINDEL PALMER. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2005-11-09 |
|
|
Cont ID |
|
| Sent By |
mamini |
Date |
2005-11-09 |
Time |
08:40 |
Rev Time |
1.00 |
| Received By |
mamini |
Date |
2005-11-09 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2005-11-09 00:00:00 | FAILED: | | | | | | 1. PLEASE NOTE THAT CIVIL PLAN FOR THIS | | | PROJECT MUST BE REVIEWD AND APPROVED BY | | | THE PUBLIC UTILITIES AND ENGINEERING FOR | | | ALL THE CONNECTIONS TO THE CITY SERVICES | | | AND FOR ANY UNDERGROUND UTILITY UPGRADE | | | OR ANY EASEMENT AS REQUIRED IN VICINITY | | | OF THE PROJECT. | | | 2. VERTICAL CLEARANCES FOR CROSSING | | | UNDERGROUND UTILITIES FOR BOTH ON-SITE | | | AND OFF-SITE MUST BE SHOWN. | | | 3. SHEET WS1 OF 5, PLEASE VERIFY EX. 6" | | | CIP AND EX. 15" VCP AND EX. 10" SAN. | | | SEWER MAIN. | | | 4. PLEASE SUBMIT STORM WATER CALCULATION | | | WHICH INCLUDE PERVIOUS AND IMPERVIOUS, | | | BUILDING AREA FOR OUR REVIEW. | | | 5. PLEASE SUBMIT A COPY OF SFWMD PERMIT | | | IF APPLIED, FOR OUR RECORD. | | | 6. SHEET PD1 & PD2 OF 5, PLEASE VERIFY | | | WEIR ELEVATION FOR THE PROPOSED CONTROL | | | STRUCTURE. | | | 7. PLEASE VERIFY, I.E(11.45')FOR | | | STRUCTURE 7 AND I.E(13.0')FOR STRUCTURE | | | 6. | | | 8. A SEPARATE PERMIT FOR ALL THE WORK | | | WITHIN PUBLIC R.O.W AT NO COST FROM | | | PUBLIC UTILITIES AND ENGINEERING IS | | | REQUIRED, PLEASE SUBMIT MOT AT THE TIME | | | OF APPLICATION, 494-1086 WINDEL PALMER. | | | 9. ACCESS RAMP PER INDEX 304 FDOT AT ALL | | | SURROUNDING INTERSECTIONS MUST BE | | | PROVIDED, PLEASE VERIFY. | | | 10. STREETSCAPINGAND SIDEWALKS, ETC. | | | MUST BE COORDINATED WITH LATEST FDOT | | | PLANS FOR THE RECONSTRUCTION OF DIXIE | | | AND SIDE STREETS. | | | 11. PLEASE NOTE THAT CIVIL PLANS MUST BE | | | SIGNED AND SEALED BY THE CIVIL E.O.R AT | | | THE TIME OF ACTUAL PERMITTING. | | | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | | MOHAMMAD R. AMINI |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
17 |
Status |
P |
Date |
2008-12-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-12-09 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-12-09 |
Time |
14:03 |
Sent To |
|
|
| Notes |
| 2008-12-09 15:47:00 | *****REVISION AND/OR RESTAMP APPROVED***** | | | | | | | | | PLAN SHEETS FA1.01 THRU FA1.12 WERE STAMPED, INITIALED, | | | AND DATED; ONLY SHEET FA1.01 WAS AN ACTUAL REVISION, | | | WHILE THE OTHERS WERE A RESTAMP OF REVISED SHEETS | | | PREVIOUSLY FIRE-STAMPED ON 01/17/08. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
16 |
Status |
P |
Date |
2008-09-10 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-09-10 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-09-10 |
Time |
14:26 |
Sent To |
|
|
| Notes |
| 2008-09-10 14:27:26 | REVISION #28 DATED 8/18/08 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
15 |
Status |
P |
Date |
2008-08-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-08-12 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-08-12 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2008-08-12 10:01:11 | *****REVISION APPROVED***** | | | | | | | | | REVISED PLAN SHEET M2.03 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
14 |
Status |
P |
Date |
2008-07-02 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-07-02 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-07-02 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2008-07-02 14:26:06 | REVISED SHEET FA1.01 DATED 6/18/08 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
13 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2008-04-09 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2008-04-09 |
Time |
15:49 |
Sent To |
|
|
| Notes |
| 2008-04-09 15:51:00 | REVISION #24 AND #25 TO ARCHITECTURAL SHEETS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
12 |
Status |
P |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-01-17 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-01-17 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2008-01-17 17:56:23 | *****APPROVED, REVISION #16, 11/10/2007***** | | | | | | | | | REVISED PLAN SHEETS E2.01, E2.02, E2.03, AND FA1.01 | | | THRU FA1.13 WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
11 |
Status |
F |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-01-17 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-01-17 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2008-01-17 16:23:52 | *****DENIED, REVISION #22***** | | | | | | | | | SEE BUILDING REVIEW COMMENT. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
10 |
Status |
N |
Date |
2007-11-01 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-01 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-01 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2007-11-01 16:49:29 | ******NOT REQUIRED***** | | | | | | | | | NO FIRE-STAMPING NEEDED FOR HE REVISED S-1.8, S-1.8R, | | | S-7.2, AND S-7.7 PLAN SHEETS. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
9 |
Status |
N |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-10-30 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-10-30 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2007-10-30 10:55:38 | REVISIONS ADDRESS BUILDING REVIEW WITH NO RESPONSE TO | | | THE LAST FIRE REVIEW. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
8 |
Status |
F |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-09-21 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-09-21 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2007-09-21 11:06:58 | ***DENIED*** | | | | | | 1) PLEASE SEE ELECTRICAL COMMENT #2 AND CLARIFY EXIT | | | SIGN LOCATION. ANY CHANGE TO MEANS OF EGRESS SHOULD BE | | | REFLECTED ON LIFE SAFETY SHEETS WHERE PROVIDED. | | | | | | 2) MANY REVISIONS IDENTIFY CHANGES TO FLOOR ELEVATIONS. | | | IN ADDITION TO APPLICABLE BUILDING CODES, PLEASE SHOW | | | COMPLIANCE WITH NFPA 101, CHAPTER 7 WITH REGARDS TO | | | WALKING SURFACES THAT IMPACT REQUIRED MEANS OF EGRESS. | | | | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
7 |
Status |
P |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-17 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-17 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2007-09-17 16:59:59 | *****APPROVED***** | | | | | | | | | FIRE PUMP SUBMITTALS |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
6 |
Status |
P |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-08-31 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-08-31 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2007-08-31 11:40:32 | FIRE EXTINGUISHER PACKAGE SUBMITTAL DATED 8/17/07. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
5 |
Status |
F |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-12 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-12 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2007-06-12 15:44:18 | ***** UNSAT SUBMITTAL***** | | | | | | | | | THE SUBMITTALS WHICH WERE REVIEWED BY THIS WRITER WERE | | | DATE STAMPED WITH THE EXCEPTION OF THE HYDRAULIC | | | CALCULATIONS FOR THE STANDPIPE WHICH SHOWS 4.462 PSI AS | | | THE SAFETY MARGIN.AS PER WEST PALM BEACH FIRE | | | PREVENTION, A SAFETY MARGIN OF AT LEAST 5.0 PSI IS | | | REQUIRED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-01-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-01-10 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-01-10 |
Time |
12:48 |
Sent To |
|
|
| Notes |
| 2007-01-10 13:08:56 | *****APPROVED***** | | | | | | | | | **REVISED PLAN SHEETS DATED 11/10/2006:FP-2.01, 2.02, | | | 2.03, 2.04, 2.05,A-2.1.1,LS-1, AND LS-2 WERE | | | STAMPED, INITIALED, AND DATED.** | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2006-08-08 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-08-08 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-08-08 |
Time |
09:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2006-05-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2006-05-30 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2006-05-30 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2006-05-30 00:00:00 | ***DENIED*** | | | | | | PLEASE NOTE THAT WHEN RESUBMITTING | | | PLANS, A RESPONSE LETTER INDICATING | | | SHEET NUMBER WOULD HELP EXPEDITE THE | | | PLAN REVIEW PROCESS. SOME REVISION | | | CLOUDS ARE SHOWN, HOWEVER IT IS UNCLEAR | | | WHAT THE CHANGE IS REFERENCING. | | | | | | PREVIOUS REVIEW COMMENTS: | | | | | | 1) BUILDING SHALL MEET THE REQUIREMENTS | | | FOR HIGHRISE IN ACCORDANCE WITH NFPA | | | 101, CHAPTER 11 AND APPLICABLE BUILDING | | | CODES. | | | | | | 2) PARKING GARAGES SHALL MEET THE | | | SEPARATION AND ALL OTHER REQUIREMENTS OF | | | NFPA 88A AND FBC. | | | | | | 3) OK | | | | | | 4) DO TRASH CHUTES OBSTRUCT CORRIDORS | | | GREATER THAN 1/2 THE WIDTH? | | | | | | 5) ILLUMINATED EXIT SIGNS TO BE MOUNTED | | | AT DISTANCES NOT TO EXCEED 100' BETWEEN | | | SIGNS. | | | | | | 6) OK | | | | | | 7) PLEASE PROVIDE QUANTITY AND TYPE OF | | | STORAGE THAT WILL BE KEPT IN POOL | | | EQUIPMENT ROOM. | | | | | | 8) EXIT STAIRS TO BE KEPT UP WITH | | | CONSTRUCTION. | | | | | | 9) OK | | | | | | 10) OK | | | | | | 11) OK | | | | | | 12) OK | | | | | | 13) THE SQUARE FOOTAGE REQUIREMENT IS | | | CALLED OUT ON PLANS. FIRE EXTINGUISHERS | | | TO BE MOUNTED AT DISTANCES NOT TO EXCEED | | | 75' TRAVEL DISTANCE REQUIREMENT. | | | | | | 14) OK | | | | | | 15) WARNING SIGNS REQUIRED IN ELEVATOR | | | LOBBIES. | | | | | | 16) NO STORAGE PERMITTED IN ELECTRICAL | | | AND MECHANICAL EQUIPMENT ROOMS. | | | | | | 17) OK | | | | | | 18) FIRE EXTINGUISHERS REQUIRED FOR EACH | | | COMMERCIAL SPACE. | | | | | | 19) PLANS INDICATE THAT ALL INTERIOR | | | FINISH IS CLASS A. DOES THAT INCLUDE ALL | | | SPACES IE, EXIT ENCLOSURES, LOBBIES AND | | | CORRIDORS, AND OTHER SPACES? | | | | | | 20) OK | | | | | | 21) OK | | | | | | 22) SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | 23) FIRE ALARM TO MEET SURVIVABILITY | | | REQUIREMENTS OF NFPA 72. | | | | | | 24) NOTE SHOULD READ: FIRE ALARM SYSTEM | | | SHALL BE UL CERTIFIED FOR 'CENTRAL | | | STATION SERVICE'. | | | | | | 25) OK | | | | | | 26) FIRE ALARM PLANS STILL DON'T SHOW | | | SMOKE DETECTOR IN FIRE COMMAND ROOM. | | | | | | 27) OK | | | | | | 28) OK | | | | | | 29) OK | | | | | | 30) OK | | | | | | 31) OK | | | | | | 32) PLEASE ILLUSTRATE THE FIRE | | | PROTECTION LAYOUT FOR THE TRASH CHUTES. | | | | | | 33) SEPARATE SHOP DRAWINGS, PERMIT AND | | | MANUFACTURER SPEC SHEETS REQUIRED FOR | | | FIRE PUMP AND ASSOCIATED EQUIPMENT. | | | | | | 34) OK | | | | | | 35) OK | | | | | | 36) OK | | | | | | NEW COMMENTS | | | | | | 37) LIFE SAFETY TO COMPLY WITH NFPA 101, | | | 2003 EDITION | | | | | | 38) PLEASE INDICATE FIRE RATING OF DOORS | | | IN TERMS OF HOURS OR MINUTES. | | | | | | 39) DUCT SMOKE DETECTORS SHALL INITIATE | | | A GENERAL FIRE ALARM IN ACCORDANCE WITH | | | LOCAL REQUIREMENTS. SHT FA 1.13 NOTE 17. | | | | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2005-11-29 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2005-11-29 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2005-11-29 |
Time |
13:42 |
Sent To |
|
|
| Notes |
| 2005-11-29 00:00:00 | ******DENIED****** | | | | | | 1) BUILDING SHALL MEET THE REQUIREMENTS | | | FOR HIGHRISE IN ACCORDANCE WITH NFPA | | | 101, CHAPTER 11 AND APPLICABLE BUILDING | | | CODE. | | | | | | 2) PARKING GARAGES SHALL MEET SEPARATION | | | AND ALL OTHER REQUIREMENTS IN ACCORDANCE | | | WITH FBC AND NFPA 88-A. | | | | | | 3) HANDRAILS REQUIRED ON STAIRS LEADING | | | TO MEZZANINE. OK ON STAIR DETAIL. | | | | | | 4) DO TRASH CHUTE DOORS OBSTRUCT | | | CORRIDORS GREATER THAN 1/2 THE WIDTH? | | | | | | 5) ILLUMINATED EXIT SIGNS SHALL BE | | | MOUNTED NOT MORE THAN 100' APART. | | | | | | 6) IS THE ROOM LABELED TRASH CHUTE | | | CORRECT? SHT. A- 0.3. | | | | | | 7) PLEASE PROVIDE QUANTITY AND TYPE OF | | | STORAGE THAT WILL BE KEPT IN POOL | | | EQUIPMENT ROOM. | | | | | | 8) EXIT STAIRS TO BE KEPT UP WITH | | | CONSTRUCTION. | | | | | | 9) SIGNS ARE REQUIRED IN STAIRWELLS | | | INDICATING TOP, BOTTOM, FLOOR # AND ROOF | | | ACCESS. | | | | | | 10) PLEASE PROVIDE OCCUPANT LOAD FOR | | | POOL AREA AND HEALTH CLUB. | | | | | | 11) PLEASE NOTE ON PLANS THAT WALKING | | | SURFACE AT POOL DECK TO BE SLIP | | | RESISTANT. | | | | | | 12) PLEASE PROVIDE MORE INFORMATION | | | REGARDING EMERGENCY ROOM. USE? | | | | | | 13) 2A-10 B,C RATED FIRE EXTINGUISHERS | | | ARE REQUIRED AND SHALL BE MOUNTED TO | | | SATISFY THE 75' TRAVEL DISTANCE | | | REQUIREMENT. | | | | | | 14) PLEASE INDICATE WHAT ELEVATORS ARE | | | STETCHER ACCESSIBLE. | | | | | | 15) WARNING SIGNS REQUIRED FOR ELEVATOR | | | LOBBIES. | | | | | | 16) NO STORAGE IN ELECTRICAL AND | | | ELEVATOR MACHINE ROOMS. | | | | | | 17) EXIT SIGN ON LS SHTS NEAR STAIR #1 | | | IS NOT AT THE STAIRWELL, BUT IS OK ON | | | ELECTRICAL SHTS. | | | | | | 18) FIRE EXTINGUISHERS ARE REQUIRED FOR | | | EACH COMMERCIAL SPACE. | | | | | | 19) NOTE A ON LS SHTS INDICATES THAT ALL | | | INTERIOR FINISH TO BE CLASS A. PLEASE | | | CLARIFY. | | | | | | 20) TRAVEL DISTANCE ON LS SHTS | | | ILLUSTRATES 278'. PLEASE SEE NFPA 101, | | | 2003 EDITION SECTION 30.2.6.4 THAT | | | STATES THAT TRAVEL DISTANCE SHALL NOT | | | EXCEED 250' IN SPRINKLERED BUILDING. | | | | | | 21) PLEASE NOTE THAT SOME EXIT SIGNS ON | | | LS SHTS ARE IN DIFFERENT LOCATIONS. | | | PLEASE CORRULATE. | | | | | | 22) SEPARATE SHOP DRAWINGS AND PERMITS | | | REQUIRED FOR FIRE SPRINKLER AND FIRE | | | ALARM SYSTEMS. | | | | | | 23) FIRE ALARM SYSTEM TO MEET | | | SURVIVABILITY REQUIREMENTS IN ACCORDANCE | | | WITH NFPA 72. | | | | | | 24) FIRE ALARM SYSTEM TO BE UL CERTIFIED | | | FOR CENTRAL STATION SERVICE. | | | | | | 25) KNOX BOX LOCKING CAPS REQUIRED FOR | | | FDC'S. HIGHRISE BUILDINGS SHALL HAVE NOT | | | LESS THAN (2) FDC'S. | | | | | | 26) PLANS DON'T SHOW SMOKE DETECTOR IN | | | FIRE ALARM CONTROL ROOM. | | | | | | 27) FIRE ALARM SYSTEM TO BE CLASS A, | | | STYLE D OR FULLY ADDRESSABLE. | | | | | | 28) IT APPEARS THAT SOME SMOKE DETECTORS | | | ARE MISSING IN SOME OF THE EQUIPMENT | | | ROOMS AND STORAGE AREAS. | | | | | | 29) SMOKE DETECTORS ARE REQUIRED IN ALL | | | COMMON AREA CORRIDORS. NOT SHOWN ON | | | PLANS. | | | | | | 30) STANDPIPES TO BE 2 1/2" WITH 1 1/2" | | | REDUCERS. | | | | | | 31) TEMPORARY STANDPIPES REQUIRED WHEN | | | BUILDING REACHED 3 STORIES OR 30" IN | | | HEIGHT. | | | | | | 32) PLEASE INDICATE THE FIRE PROTECTION | | | LAYOUT WITHIN THE TRASH CHUTES. | | | | | | 33) SEPARATE SHOP DRAWINGS, PERMIT AND | | | MANUFACTURER SPEC SHTS REQUIRED FOR FIRE | | | PUMP. | | | | | | 34) NFPA 13, 2002 EDITION TO BE | | | REFERENCED. SHT FP 4.02. | | | | | | 35) NO CUTTING OR WELDING OPERATIONS TO | | | OCCUR WITHOUT APPROVAL OF BUREAU OF FIRE | | | PREVENTION AND COMPLIANCE WITH NFPA | | | 51-B. | | | | | | 36) IN ADDITION TO ELECTRONIC SWITCHES, | | | DOUBLE CHECK DETECTOR ASSEMBLY TO BE | | | SECURED WITH LOCK AND CHAIN. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
6 |
Status |
P |
Date |
2008-09-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-02 |
Time |
12:28 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-02 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2008-09-02 12:29:24 | REVISION OK -- SHT P3.16 GAS ONLY |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
5 |
Status |
F |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-21 |
Time |
08:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-20 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2008-08-21 08:40:55 | REVISION DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | *****SEPARATE GAS PERMIT REQUIRED***** | | | | | | ****FROM PREVIOUS REVISION REVIEW: | | | | | | 1. SHT P3.16 GAS METER PIPING SCHEMATIC NOT APPROVED. A | | | LETTER FROM FLORIDA PUBLIC UTILITIES AUTHORIZING THE | | | BYPASS OF THE GAS METER IS REQUIRED AS PROVIDER OF THE | | | GAS. | | | ****RESPONSE NOTED, BUT THE GAS METER PIPING SCHEMATIC | | | SHOWS A TEE ON THE OUTLET SIDE OF THE METER WITH A | | | CAPPED LINE. PLEASE INDICATE WHAT THIS LINE IS FOR. IF | | | IT IS FOR FUTURE USE, A SHUT OFF VALVE IS REQUIRED | | | BETWEEN THE TEE AND THE CAP. ALSO DOWNSTREAM OF THE TEE | | | ON THE PIPING TO THE BUILDING, (2PSI), SHOWS A SHUT OFF | | | VALVE, A 90 DEG FITTING AND THEN ANOTHER SHUT OFF | | | VALVE. PLEASE EXPLAIN WHY TWO SHUT OFF VALVES ARE | | | NEEDED. SECTIONS 106.1.2, 106.1.1 & 409. | | | | | | 2. OK | | | 3. OK | | | 4. OK | | | | | | 5. SUBMIT MANUF. SPECIFICATIONS FOR THE REGULATORS. | | | INDICATE MODEL NUMBER AND SHOW MAX CAPACITY FOR TOTAL | | | LOAD OF ALL APPLIANCES COMBINED. | | | ****RESPONSE NOTED, BUT THE MAXIMUM CAPACITY FOR THE | | | GAS REGULATOR IS NOT INDICATED. 410.2(3) | | | | | | 6. OK | | | | | | 7. SEE BELOW FOR PROVISO FROM PLANS STAMPED AT TIME OF | | | PERMIT FOR THE BUILD COM: | | | | | | PASSED/PROVISO | | | | | | MANUF. SPECIFICATION SHEETS REQUIRED AT | | | THE TIME OF BUILD-0UT OF KITCHEN, AND AT | | | THE TIME OF APPLICATION FOR THE GAS | | | PERMIT FOR THE POOL HEATERS. - MANUF. SPECIFICATION | | | SHEET ALSO REQUIRED FOR | | | THE GAS REGULATORS. INDICATE THE MODEL | | | NUMBER FOR REGULATORS. REGULATORS SHALL | | | BE LISTED. | | | ****RESPONSE NOTED, BUT THERE IS NO LISTING INDICATED | | | ON THE SUBMITTALS FOR THE REGULATORS. THE SUBMITTALS | | | SHOW REGULATORS MANUF. IN ENGLAND. THERE IS A JEAVONS | | | J48 REGULATOR MADE BY AMERICAN METER THAT IS LISTED AND | | | APPROVED AY AGA & CAGA THAT CAN BE USED. SECTION | | | 410.2(1). | | | | | | | | | REVISION REQUIRED FOR SHT P3.16 | | | INDICATING THE CORRECT INLET PRESSURE | | | FROM THE METER, AND SHOWING UNIONS | | | DOWNSTREAM OF THE SHUT OFF VALVES FOR | | | THE REGULATORS.-PIPE SIZING SHALL BE | | | CHECKED WHEN INLET PRESSURE IS | | | CLARIFIED. | | | ****RESPONSE NOTED, BUT THE REVISION FOR THE POOL | | | BOILER EQUIPMENT INFORMATION BLOCK STILL SHOWS THE MOST | | | REMOTE POOL HEATER/BOILER TO BE 10 FEET FROM THE | | | REGULATOR. THE RISER DIAGRAM INDICATES AT LEAST 20 | | | FEET. PLEASE CORRELATE. SECTION 106.1.1. | | | | | | ***********NEW COMMENT*********** | | | | | | 1B. SHT P3.16 THE GAS METER PIPING SCHEMATIC DOES NOT | | | REFLECT THE RISER DIAGRAMS. PLEASE INDICATE IF THE | | | PIPING SCHEMATIC IS FOR BOTH METERS OR FOR ONE METER. | | | IF FOR BOTH METERS THEN THE RISER DIAGRAMS SHALL | | | REFLECT THE PIPING SCHEMATIC FOR THE GAS METERS. | | | | | | 2B. SHT P3.16 REGULATOR SCHEDULE SHOWS 5 REGULATORS, | | | BUT ONLY 2 REGULATORS ARE SHOWN ON THE RISER DIAGRAMS. | | | PLEASE SHOW WHERE EACH REGULATOR IS LOCATED ON THE | | | RISER DIAGRAMS. SECTION 106.1.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
F |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-06 |
Time |
12:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-06 |
Time |
12:39 |
Sent To |
|
|
| Notes |
| 2008-08-06 14:40:24 | REVISION DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | *****SEPARATE GAS PERMIT REQUIRED***** | | | | | | 1. SHT P3.16 GAS METER PIPING SCHEMATIC NOT APPROVED. A | | | LETTER FROM FLORIDA PUBLIC UTILITIES AUTHORIZING THE | | | BYPASS OF THE GAS METER IS REQUIRED AS PROVIDER OF THE | | | GAS. | | | | | | 2. SHT P3.1.6 THERE ARE CHANGES TO THE PLANS FROM | | | PREVIOUS REVISION, (13), THAT ARE NOT INDICATED WITH A | | | CLOUD OR A REVISION NUMBER. PLEASE CLOUD AND NUMBER ALL | | | REVISIONS. SECTION 106.1.3. | | | | | | 3. SHT P3.1.6 PIPE SIZING DOWNSTREAM OF THE REGULATOR | | | TO THE POOL/SPA BOILERS IS NOT CORRECT PER TABLE | | | 402.4(2). EACH STUBOUT & VALVE FOR THE POOL BOILERS | | | SHALL BE 1". (3/4" IS SHOWN). 1" IS REQUIRED TO THE | | | LAST POOL HEATER. (3/4" IS SHOWN). 1-1/4" IS REQUIRED | | | TO POOL BOILER #2. (1" IS SHOWN). 1-1/2" IS REQUIRED | | | FROM THE REGULATOR TO THE SPA BOILER. (1" IS SHOWN). | | | PLEASE SEE RED LINE CORRECTION ON SUBMITTED REVISION. | | | | | | 4. SUBMIT MANUF. SPECIFICATIONS FOR THE POOL/SPA | | | BOILERS. INDICATE MODEL NUMBER, LISTING & BTU LOAD FOR | | | EACH. | | | | | | 5. SUBMIT MANUF. SPECIFICATIONS FOR THE REGULATORS. | | | INDICATE MODEL NUMBER AND SHOW MAX CAPACITY FOR TOTAL | | | LOAD OF ALL APPLIANCES COMBINED. | | | | | | 6. SHT P3.1.6 GAS RISER DIAGRAM. UNIONS ARE REQUIRED | | | DOWNSTREAM OF THE SHUT OFF VALVE FOR THE GAS | | | REGULATORS. PLEASE SHOW ON RISER DIAGRAM. | | | | | | 7. SEE BELOW FOR PROVISO FROM PLANS STAMPED AT TIME OF | | | PERMIT FOR THE BUILD COM: | | | | | | PASSED/PROVISO | | | | | | MANUF. SPECIFICATION SHEETS REQUIRED AT | | | THE TIME OF BUILD-0UT OF KITCHEN, AND AT | | | THE TIME OF APPLICATION FOR THE GAS | | | PERMIT FOR THE POOL HEATERS. - MANUF. SPECIFICATION | | | SHEET ALSO REQUIRED FOR | | | THE GAS REGULATORS. INDICATE THE MODEL | | | NUMBER FOR REGULATORS. REGULATORS SHALL | | | BE LISTED. | | | | | | | | | REVISION REQUIRED FOR SHT P3.16 | | | INDICATING THE CORRECT INLET PRESSURE | | | FROM THE METER, AND SHOWING UNIONS | | | DOWNSTREAM OF THE SHUT OFF VALVES FOR | | | THE REGULATORS.-PIPE SIZING SHALL BE | | | CHECKED WHEN INLET PRESSURE IS | | | CLARIFIED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-28 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-26 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2006-08-28 00:00:00 | | | | | | | PASSED/PROVISO | | | | | | MANUF. SPECIFICATION SHEETS REQUIRED AT | | | THE TIME OF BUILD-0UT OF KITCHEN, AND AT | | | THE TIME OF APPLICATION FOR THE GAS | | | PERMIT FOR THE POOL HEATERS. - MANUF. SPECIFICATION | | | SHEET ALSO REQUIRED FOR | | | THE GAS REGULATORS. INDICATE THE MODEL | | | NUMBER FOR REGULATORS. REGULATORS SHALL | | | BE LISTED. | | | | | | | | | REVISION REQUIRED FOR SHT P3.16 | | | INDICATING THE CORRECT INLET PRESSURE | | | FROM THE METER, AND SHOWING UNIONS | | | DOWNSTREAM OF THE SHUT OFF VALVES FOR | | | THE REGULATORS.-PIPE SIZING SHALL BE | | | CHECKED WHEN INLET PRESSURE IS | | | CLARIFIED. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2006-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-04 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-04 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2006-08-07 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | FROM PLUMBING REVIEW: | | | | | | 34B. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | ****RESPONSE NOTED, BUT THE GAS LINE TO | | | THE POOL HEATER APPEARS TO BE RUN IN THE | | | 5TH FLOOR CEILING. WILL THE POOL HEATER | | | BE LOCATED IN THE CEILING, OR WILL THERE | | | BE A DROP TO THE HEATER. PLEASE CLARIFY. | | | | | | B. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). (EACH SYSTEM). | | | ****RESPONSE NOTED, BUT THE TABLE SHOWN | | | IS FROM FBC-2001 FUEL GAS CODE. PLEASE | | | DESIGN AND INDICATE TABLE FROM FBC-2004 | | | FUEL GAS CODE. | | | C. OK | | | | | | D. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. (EACH SYSTEM). | | | ****NOT ADDRESSED. | | | | | | E. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (EACH SYSTEM). | | | ****NOT ADDRESSED. | | | | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. (EACH | | | SYSTEM). | | | ****NOT ADDRESSED. ITS UNDERSTOOD THE | | | KITCHEN GAS EQUIPMENT WILL BE SUBMITTED | | | AT KITCHEN BUILD-OUT, BUT THE POOL | | | HEATER SPECIFICATIONS SHEETS WILL BE | | | REQUIRED. | | | | | | G. AT KITCHEN BUILD-0UT. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2006-05-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-05-27 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-05-27 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2006-05-27 00:00:00 | DENIED | | | REFERENCE: FBC-2004 FUEL GAS | | | | | | FROM BUILDING PLAN REVIEW: | | | | | | 34B. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | B. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). (EACH SYSTEM). | | | C. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). (EACH | | | SYSTEM). | | | D. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. (EACH SYSTEM). | | | E. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (EACH SYSTEM). | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. (EACH | | | SYSTEM). | | | G. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. (FOR | | | KITCHEN SYSTEM ONLY). | | | | | | 35B. THERE IS ONE SET OF "RED LINED" | | | PLANS. PLEASE RETURN THIS SET AND | | | COMMENT RESPONSES TO HELP EXPEDITE THE | | | NEXT PLAN REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
127 |
Status |
N |
Date |
2008-12-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-23 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-23 |
Time |
16:05 |
Sent To |
P |
|
| Notes |
| 2008-12-23 16:05:51 | TO "P" BOX/ 2 REV'S |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
126 |
Status |
N |
Date |
2008-12-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-12-08 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-12-08 |
Time |
15:47 |
Sent To |
P |
|
| Notes |
| 2008-12-08 15:47:43 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
125 |
Status |
N |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-06 |
Time |
13:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-06 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2008-11-06 13:05:24 | TO "COMM" BD#59 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
124 |
Status |
N |
Date |
2008-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-06 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-06 |
Time |
12:55 |
Sent To |
P |
|
| Notes |
| 2008-11-06 12:56:03 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
123 |
Status |
N |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-11-03 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-11-03 |
Time |
09:41 |
Sent To |
B |
|
| Notes |
| 2008-11-03 09:42:23 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
122 |
Status |
N |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-06 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-06 |
Time |
10:09 |
Sent To |
E |
|
| Notes |
| 2008-10-06 10:09:41 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
121 |
Status |
N |
Date |
2008-10-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-10-06 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-10-06 |
Time |
08:58 |
Sent To |
M |
|
| Notes |
| 2008-10-06 08:58:24 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
120 |
Status |
N |
Date |
2008-09-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-25 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-25 |
Time |
13:05 |
Sent To |
E |
|
| Notes |
| 2008-09-25 13:05:43 | TO "DPALMER' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
119 |
Status |
N |
Date |
2008-09-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-25 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-25 |
Time |
09:59 |
Sent To |
M |
|
| Notes |
| 2008-09-25 09:59:28 | TO "M" BOX/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
118 |
Status |
N |
Date |
2008-09-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-22 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-22 |
Time |
14:23 |
Sent To |
E |
|
| Notes |
| 2008-09-22 14:23:58 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
117 |
Status |
N |
Date |
2008-09-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-15 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-15 |
Time |
13:57 |
Sent To |
E |
|
| Notes |
| 2008-09-15 13:58:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
116 |
Status |
N |
Date |
2008-09-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-11 |
Time |
08:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-11 |
Time |
08:39 |
Sent To |
E |
|
| Notes |
| 2008-09-11 08:40:14 | TO "DPALMER" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
115 |
Status |
N |
Date |
2008-09-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-09-05 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-09-05 |
Time |
10:25 |
Sent To |
B |
|
| Notes |
| 2008-09-05 10:25:58 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
114 |
Status |
N |
Date |
2008-08-28 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-28 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-28 |
Time |
14:05 |
Sent To |
Z |
|
| Notes |
| 2008-08-28 14:06:04 | TO "ZONING"BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
113 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-27 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-27 |
Time |
10:59 |
Sent To |
B |
|
| Notes |
| 2008-08-27 11:00:13 | TO "BUILD" JIM W. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
112 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-27 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-27 |
Time |
11:00 |
Sent To |
P |
|
| Notes |
| 2008-08-27 11:01:01 | TO "PLUMB" KEN S. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
111 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-27 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-27 |
Time |
08:58 |
Sent To |
G |
|
| Notes |
| 2008-08-27 08:59:39 | TO "GAS" KEN S. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
110 |
Status |
N |
Date |
2008-08-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-27 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-27 |
Time |
08:51 |
Sent To |
Z |
|
| Notes |
| 2008-08-27 08:52:15 | TO "ZONING" BOX. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
109 |
Status |
N |
Date |
2008-08-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-08-25 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2008-08-25 |
Time |
15:00 |
Sent To |
|
|
| Notes |
| 2008-08-25 15:01:06 | TO "COMM" BD #2. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
108 |
Status |
N |
Date |
2008-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-21 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-21 |
Time |
12:40 |
Sent To |
B |
|
| Notes |
| 2008-08-21 12:41:12 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
107 |
Status |
N |
Date |
2008-08-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-18 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-18 |
Time |
16:21 |
Sent To |
P |
|
| Notes |
| 2008-08-18 16:22:01 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
106 |
Status |
N |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-08 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-08 |
Time |
14:14 |
Sent To |
E |
|
| Notes |
| 2008-08-08 14:14:37 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
105 |
Status |
N |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-06 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-06 |
Time |
10:34 |
Sent To |
M |
|
| Notes |
| 2008-08-06 10:34:27 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
104 |
Status |
N |
Date |
2008-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-06 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-06 |
Time |
09:27 |
Sent To |
E |
|
| Notes |
| 2008-08-06 09:27:47 | TO "DPALMER' DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
103 |
Status |
N |
Date |
2008-08-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-04 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-04 |
Time |
11:15 |
Sent To |
B |
|
| Notes |
| 2008-08-04 11:16:11 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
102 |
Status |
N |
Date |
2008-08-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-08-01 |
Time |
09:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-08-01 |
Time |
09:46 |
Sent To |
M |
|
| Notes |
| 2008-08-01 09:46:34 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
101 |
Status |
N |
Date |
2008-07-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-29 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-29 |
Time |
14:59 |
Sent To |
B |
|
| Notes |
| 2008-07-29 15:00:07 | TO "JWITMER" DESK/4 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
100 |
Status |
N |
Date |
2008-07-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-22 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-22 |
Time |
10:40 |
Sent To |
B |
|
| Notes |
| 2008-07-22 10:40:46 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
99 |
Status |
N |
Date |
2008-07-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-17 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-17 |
Time |
11:30 |
Sent To |
M |
|
| Notes |
| 2008-07-17 11:31:21 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
98 |
Status |
N |
Date |
2008-07-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-10 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-10 |
Time |
09:28 |
Sent To |
Z |
|
| Notes |
| 2008-07-10 09:28:45 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
97 |
Status |
N |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-24 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-24 |
Time |
16:57 |
Sent To |
B |
|
| Notes |
| 2008-06-24 16:58:17 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
96 |
Status |
N |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-19 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-19 |
Time |
15:13 |
Sent To |
E |
|
| Notes |
| 2008-06-19 15:13:29 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
95 |
Status |
N |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-19 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-19 |
Time |
15:10 |
Sent To |
M |
|
| Notes |
| 2008-06-19 15:10:28 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
94 |
Status |
N |
Date |
2008-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-19 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-19 |
Time |
15:01 |
Sent To |
FIRE |
|
| Notes |
| 2008-06-19 15:01:35 | TO "F" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
93 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-06 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-06 |
Time |
14:50 |
Sent To |
E |
|
| Notes |
| 2008-06-06 14:51:14 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
92 |
Status |
N |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-30 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-30 |
Time |
11:19 |
Sent To |
B |
|
| Notes |
| 2008-05-30 11:20:25 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
91 |
Status |
N |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-30 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-30 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2008-05-30 10:10:31 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
90 |
Status |
N |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-30 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-30 |
Time |
09:45 |
Sent To |
E |
|
| Notes |
| 2008-05-30 09:45:51 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
89 |
Status |
N |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-21 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-21 |
Time |
14:35 |
Sent To |
B |
|
| Notes |
| 2008-05-21 14:36:19 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
88 |
Status |
N |
Date |
2008-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-08 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-08 |
Time |
10:55 |
Sent To |
E |
|
| Notes |
| 2008-05-08 10:56:15 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
87 |
Status |
N |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-30 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-30 |
Time |
09:21 |
Sent To |
|
|
| Notes |
| 2008-04-30 09:25:30 | TO "COMM" BD#13 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
86 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-17 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-17 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2008-04-17 10:50:33 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
85 |
Status |
N |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-17 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-17 |
Time |
09:08 |
Sent To |
B |
|
| Notes |
| 2008-04-17 09:09:02 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
84 |
Status |
N |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-07 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-07 |
Time |
15:09 |
Sent To |
E |
|
| Notes |
| 2008-04-07 15:10:18 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
83 |
Status |
N |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-07 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-07 |
Time |
15:09 |
Sent To |
M |
|
| Notes |
| 2008-04-07 15:09:17 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
82 |
Status |
N |
Date |
2008-04-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-07 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-07 |
Time |
14:49 |
Sent To |
Z |
|
| Notes |
| 2008-04-07 14:50:22 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
81 |
Status |
N |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-26 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-26 |
Time |
15:05 |
Sent To |
|
|
| Notes |
| 2008-03-26 15:09:42 | TO "COMM" BD#11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
80 |
Status |
N |
Date |
2008-03-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-26 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-26 |
Time |
14:43 |
Sent To |
B |
|
| Notes |
| 2008-03-26 14:44:17 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
79 |
Status |
N |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-19 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-19 |
Time |
11:58 |
Sent To |
B |
|
| Notes |
| 2008-03-19 11:59:15 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
78 |
Status |
N |
Date |
2008-03-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-03-19 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-03-19 |
Time |
11:38 |
Sent To |
E |
|
| Notes |
| 2008-03-19 11:40:49 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
77 |
Status |
N |
Date |
2008-03-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-13 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-13 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2008-03-13 09:24:23 | TO "COMM" BD#15 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
76 |
Status |
N |
Date |
2008-03-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-12 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-12 |
Time |
16:54 |
Sent To |
G |
|
| Notes |
| 2008-03-12 16:54:58 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
75 |
Status |
N |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-05 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-05 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2008-03-05 12:14:44 | TO "COMM" BD#24 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
74 |
Status |
N |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-03-03 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-03-03 |
Time |
14:24 |
Sent To |
|
|
| Notes |
| 2008-03-03 14:24:43 | TO "COMM" BD#58 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
73 |
Status |
N |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-21 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-21 |
Time |
10:04 |
Sent To |
M |
|
| Notes |
| 2008-02-21 10:05:01 | TO "M" BOX/1 REV AND 1 SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
72 |
Status |
N |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-12 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-12 |
Time |
16:05 |
Sent To |
M |
|
| Notes |
| 2008-02-12 16:05:55 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
71 |
Status |
N |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-12 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-12 |
Time |
15:29 |
Sent To |
B |
|
| Notes |
| 2008-02-12 15:29:33 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
70 |
Status |
N |
Date |
2008-01-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-29 |
Time |
08:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-29 |
Time |
08:35 |
Sent To |
M |
|
| Notes |
| 2008-01-29 08:35:50 | TO "RREGUIERO" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
69 |
Status |
N |
Date |
2008-01-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-28 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-28 |
Time |
11:33 |
Sent To |
P |
|
| Notes |
| 2008-01-28 11:33:46 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
68 |
Status |
N |
Date |
2008-01-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-24 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-24 |
Time |
11:22 |
Sent To |
B |
|
| Notes |
| 2008-01-24 11:23:08 | TO "JWITMER" DESK/3 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
67 |
Status |
N |
Date |
2008-01-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-18 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-18 |
Time |
12:06 |
Sent To |
B |
|
| Notes |
| 2008-01-18 12:06:36 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
66 |
Status |
N |
Date |
2008-01-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-14 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-14 |
Time |
13:47 |
Sent To |
B |
|
| Notes |
| 2008-01-14 13:54:01 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
65 |
Status |
N |
Date |
2008-01-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-09 |
Time |
17:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-09 |
Time |
17:04 |
Sent To |
M |
|
| Notes |
| 2008-01-09 17:04:45 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
64 |
Status |
N |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-13 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-13 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2007-12-13 16:47:18 | TO "COMM" BD#39--ELECT AND FIRE ALARM REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
63 |
Status |
N |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-13 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-13 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2007-12-13 16:30:12 | TO "COMM" BD#40--"Z", "BLDG" AND "F" REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
62 |
Status |
N |
Date |
2007-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-13 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-13 |
Time |
16:16 |
Sent To |
M |
|
| Notes |
| 2007-12-13 16:16:59 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
61 |
Status |
N |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-28 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-28 |
Time |
10:40 |
Sent To |
M |
|
| Notes |
| 2007-11-28 10:41:08 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
60 |
Status |
N |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-28 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-28 |
Time |
10:34 |
Sent To |
P |
|
| Notes |
| 2007-11-28 10:34:34 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
59 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-19 |
Time |
14:34 |
Sent To |
B |
|
| Notes |
| 2007-11-19 14:35:00 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
58 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-19 |
Time |
14:22 |
Sent To |
M |
|
| Notes |
| 2007-11-19 14:22:32 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
57 |
Status |
N |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-06 |
Time |
16:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-06 |
Time |
16:28 |
Sent To |
M |
|
| Notes |
| 2007-11-06 16:29:10 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
56 |
Status |
N |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-06 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-06 |
Time |
16:25 |
Sent To |
B |
|
| Notes |
| 2007-11-06 16:26:04 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
55 |
Status |
|
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-19 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-19 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2007-11-05 11:32:22 | TO "COMM" BD#29 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
54 |
Status |
N |
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-19 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-19 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2007-11-05 10:19:52 | TO "COMM" BD#16 | | 2007-10-19 10:10:58 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
53 |
Status |
N |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-11 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-11 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2007-10-12 16:23:10 | TO "COMM" BD#36 | | 2007-10-11 12:37:55 | WAITING FOR "COMM" BD--REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
52 |
Status |
N |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-11 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-11 |
Time |
12:02 |
Sent To |
P |
|
| Notes |
| 2007-10-11 12:03:44 | TO "P" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
51 |
Status |
N |
Date |
2007-10-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-10 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-10 |
Time |
09:34 |
Sent To |
B |
|
| Notes |
| 2007-10-10 09:35:01 | TO "JWITMER" DESK/3 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
50 |
Status |
N |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-28 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-28 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2007-10-17 16:51:31 | TO "COMM" BD#51 | | 2007-09-28 13:50:12 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
49 |
Status |
N |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-28 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-28 |
Time |
09:53 |
Sent To |
B |
|
| Notes |
| 2007-09-28 09:54:24 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
48 |
Status |
N |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-28 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-28 |
Time |
09:51 |
Sent To |
B |
|
| Notes |
| 2007-09-28 09:51:48 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
47 |
Status |
N |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-27 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-27 |
Time |
10:48 |
Sent To |
P |
|
| Notes |
| 2007-09-27 10:48:41 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
46 |
Status |
N |
Date |
2007-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-27 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-27 |
Time |
10:44 |
Sent To |
B |
|
| Notes |
| 2007-09-27 10:45:21 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
45 |
Status |
N |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-20 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-20 |
Time |
13:20 |
Sent To |
P |
|
| Notes |
| 2007-09-20 13:20:52 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
44 |
Status |
N |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-20 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-20 |
Time |
13:15 |
Sent To |
M |
|
| Notes |
| 2007-09-20 13:15:41 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
43 |
Status |
N |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-20 |
Time |
11:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-20 |
Time |
11:54 |
Sent To |
E |
|
| Notes |
| 2007-09-20 11:54:22 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
42 |
Status |
N |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-20 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-20 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2007-09-24 16:28:49 | TO "COMM" BD#9 | | 2007-09-20 09:54:49 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
41 |
Status |
N |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-04 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-04 |
Time |
11:20 |
Sent To |
FIRE |
|
| Notes |
| 2007-09-04 11:21:19 | TO "F" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
40 |
Status |
N |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-31 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-31 |
Time |
16:49 |
Sent To |
E |
|
| Notes |
| 2007-08-31 16:49:52 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
39 |
Status |
N |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-31 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-31 |
Time |
16:43 |
Sent To |
E |
|
| Notes |
| 2007-08-31 16:43:32 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
38 |
Status |
N |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-31 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-31 |
Time |
16:38 |
Sent To |
|
|
| Notes |
| 2007-08-31 16:38:43 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
37 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-27 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-27 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2007-09-18 14:38:45 | TO "COMM" BD#24 | | 2007-08-27 10:17:15 | WAITING FOR "COMM" BD-- "MECH" AND "PLUMB" REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
36 |
Status |
N |
Date |
2007-08-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-24 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-24 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2007-09-19 14:14:45 | TO "COMM" BD#15/PLANS ON RACK-4 ROLLS--2 REV'S | | 2007-08-24 13:41:51 | WAITING FOR "COMM' BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
35 |
Status |
N |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-23 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-23 |
Time |
10:17 |
Sent To |
B |
|
| Notes |
| 2007-08-23 10:17:40 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
34 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
14:50 |
Sent To |
B |
|
| Notes |
| 2007-08-21 14:50:54 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
33 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
09:57 |
Sent To |
B |
|
| Notes |
| 2007-08-21 09:57:31 | TO "JWITMER" DESK/2 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
32 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
09:49 |
Sent To |
FIRE |
|
| Notes |
| 2007-08-21 09:50:10 | TO "F" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
31 |
Status |
N |
Date |
2007-08-08 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-08-08 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
mmiller |
Date |
2007-08-08 |
Time |
18:27 |
Sent To |
B |
|
| Notes |
| 2007-08-08 18:27:26 | SENT TO JIM WITMER'S DESK MMILLLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
30 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
15:12 |
Sent To |
Z |
|
| Notes |
| 2007-07-30 15:13:02 | TO "Z" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
29 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
15:09 |
Sent To |
P |
|
| Notes |
| 2007-07-30 15:09:51 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
28 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
15:04 |
Sent To |
M |
|
| Notes |
| 2007-07-30 15:04:36 | TO "M" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
27 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
15:00 |
Sent To |
B |
|
| Notes |
| 2007-07-30 15:01:20 | TO "JWITMER" DESK/SUBMITTED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
26 |
Status |
N |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-26 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-26 |
Time |
10:40 |
Sent To |
B |
|
| Notes |
| 2007-07-26 10:41:00 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
25 |
Status |
N |
Date |
2007-07-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-09 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-09 |
Time |
10:31 |
Sent To |
M |
|
| Notes |
| 2007-07-09 10:31:35 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
24 |
Status |
N |
Date |
2007-07-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-06 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-06 |
Time |
13:38 |
Sent To |
B |
|
| Notes |
| 2007-07-06 13:38:50 | TO "JWITMER" DESK/3 SUBMITTALS |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
23 |
Status |
N |
Date |
2007-06-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-14 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-14 |
Time |
10:45 |
Sent To |
B |
|
| Notes |
| 2007-06-14 10:46:07 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
22 |
Status |
N |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-04 |
Time |
09:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-04 |
Time |
09:12 |
Sent To |
B |
|
| Notes |
| 2007-06-04 09:12:21 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
21 |
Status |
N |
Date |
2007-05-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-25 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-25 |
Time |
10:16 |
Sent To |
B |
|
| Notes |
| 2007-05-25 10:16:37 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
20 |
Status |
N |
Date |
2007-05-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-24 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-24 |
Time |
11:49 |
Sent To |
|
|
| Notes |
| 2007-06-14 13:40:54 | TO "COMM" BD#3 | | 2007-05-24 11:50:03 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
19 |
Status |
N |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-18 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-18 |
Time |
08:55 |
Sent To |
B |
|
| Notes |
| 2007-05-18 08:55:28 | TO "KCONRAD" DESK/SUBMITTAL--FOR JERALD SMITH |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
18 |
Status |
N |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-27 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-27 |
Time |
10:48 |
Sent To |
B |
|
| Notes |
| 2007-04-27 10:48:30 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
17 |
Status |
N |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-27 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-27 |
Time |
10:47 |
Sent To |
P |
|
| Notes |
| 2007-04-27 10:48:00 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
16 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-19 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-19 |
Time |
14:16 |
Sent To |
P |
|
| Notes |
| 2007-04-19 14:16:28 | TO "P" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
15 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-19 |
Time |
14:06 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-19 |
Time |
14:06 |
Sent To |
E |
|
| Notes |
| 2007-04-19 14:07:25 | TO "DPALMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
14 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-19 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-19 |
Time |
14:03 |
Sent To |
FIRE |
|
| Notes |
| 2007-04-19 14:03:59 | TO "F" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
13 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-19 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-19 |
Time |
14:02 |
Sent To |
B |
|
| Notes |
| 2007-04-19 14:02:49 | TO "JWITMER" DESK/SUBMITTAL/3 BOXES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
12 |
Status |
N |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-19 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-19 |
Time |
11:52 |
Sent To |
B |
|
| Notes |
| 2007-04-19 11:52:48 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
11 |
Status |
N |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-16 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-16 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
| 2007-04-16 15:52:14 | TO "JIWITMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
10 |
Status |
N |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-03 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-03 |
Time |
17:29 |
Sent To |
B |
|
| Notes |
| 2007-04-03 17:29:33 | TO JIM WITMER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-29 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-29 |
Time |
19:55 |
Sent To |
P |
|
| Notes |
| 2007-03-29 19:55:33 | TO KS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-03-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-01 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-01 |
Time |
13:40 |
Sent To |
B |
|
| Notes |
| 2007-03-01 13:43:44 | TO "JWITMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-01-31 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-01-31 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-01-31 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2007-02-07 16:47:45 | TO "COMM" BD#8 | | 2007-01-31 10:36:39 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-11-16 |
Time |
08:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-11-16 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2006-11-17 13:19:14 | TO "COMM" BD#40 | | 2006-11-16 08:46:14 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-09-23 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-09-23 |
Time |
16:48 |
Sent To |
E |
|
| Notes |
| 2006-09-23 00:00:00 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-08-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-11 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-11 |
Time |
10:37 |
Sent To |
|
|
| Notes |
| 2006-08-17 00:00:00 | TO "COMM" BD#38/PLANS ON RACK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-06-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-30 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-30 |
Time |
10:56 |
Sent To |
|
|
| Notes |
| 2006-07-18 00:00:00 | TO "COMM" BD#35 | | 2006-06-30 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2006-03-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-03-15 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-03-15 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2006-04-06 00:00:00 | TO "COMM" BD#32/PLANS ON RACK-11 ROLLS | | | AND 3 BOXES | | 2006-03-30 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-09-27 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-09-27 |
Time |
09:03 |
Sent To |
|
|
| Notes |
| 2005-10-03 00:00:00 | TO "COMM" BD#41/PLANS ON RACK | | 2005-09-27 00:00:00 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2008-09-09 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2008-09-09 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
35 |
Status |
P |
Date |
2008-11-03 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-11-03 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-11-03 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2008-11-03 10:09:33 | 11/03/08 | | | SUBMITTAL'S FOR CLOTH TAPE OK. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
34 |
Status |
P |
Date |
2008-10-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-10-18 |
Time |
17:44 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-10-18 |
Time |
17:43 |
Sent To |
PC |
|
| Notes |
| 2008-10-18 17:44:10 | RESTAMP OF FULL MECH SET OF PLANS M0.0 THRU M8.01 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
33 |
Status |
P |
Date |
2008-09-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-09-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-04-18 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
32 |
Status |
P |
Date |
2008-08-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-11 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-11 |
Time |
16:32 |
Sent To |
PC |
|
| Notes |
| 2008-08-11 16:39:32 | PAGE M7.01 REVISION 19 SUPERSEDES REVISION 18. REVISION | | | 19 STAMPED AND INCORPORATED INTO PERMIT SET OF PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
31 |
Status |
P |
Date |
2008-08-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-08-05 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-08-05 |
Time |
08:55 |
Sent To |
FIRE |
|
| Notes |
| 2008-08-05 08:56:44 | REVISION 20 PG M2.03. PBC DERM APPROVED SHEET FOR | | | ADDITION OF 2000 GALLON FUEL TANK IN GENERATOR ROOM | | | WITH SHOP DRAWINGS FOR FUEL FILLING SYSTEM. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
30 |
Status |
P |
Date |
2008-07-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-07-08 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-07-08 |
Time |
10:49 |
Sent To |
PC |
|
| Notes |
| 2008-07-08 11:21:25 | REVISION #21 PAGES M2.01 AND M2.04 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
29 |
Status |
P |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-16 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-16 |
Time |
08:05 |
Sent To |
PC |
|
| Notes |
| 2008-05-16 09:57:59 | REVISION 20 PAGES: M2.02, M2.05, M2.07 THROUGH M2.30, | | | M4.01, M4.02 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
28 |
Status |
P |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-15 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-15 |
Time |
16:01 |
Sent To |
PC |
|
| Notes |
| 2008-05-15 16:02:46 | REV.19 PAGE M5.02 - ADD AHU/CU SGR1 TO DUCTLESS SPLIT | | | SYSTEM SCHEDULE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
27 |
Status |
F |
Date |
2008-05-15 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-15 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-15 |
Time |
13:28 |
Sent To |
PC |
|
| Notes |
| 2008-05-15 13:29:09 | REV.27 PG LS.15 FIRESTOP DETAIL. PLEASE SEE BUILDING | | | REVIEW COMMENTS DATED 5/12/08. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
26 |
Status |
P |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-03-25 |
Time |
19:12 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-03-25 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2008-03-25 19:13:57 | SUBMITTAL 15-500-002 4" HOOD VENT |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
25 |
Status |
P |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-03-25 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-03-25 |
Time |
18:54 |
Sent To |
E |
|
| Notes |
| 2008-03-25 18:55:53 | SUBMITTAL # 15-840-001GARAGE AIR |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
24 |
Status |
P |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-03-25 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-03-25 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2008-03-25 18:14:08 | SUBMITTAL # 15-700-15FANS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
23 |
Status |
F |
Date |
2008-03-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-03-25 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-03-25 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2008-03-25 18:09:01 | SUBMITTAL # 15-700-16 DENIED | | | PLEASE SHOW TYPE OF ANCHORS USED ON STRAP TO WALL. | | | HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
22 |
Status |
P |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-03-05 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-03-05 |
Time |
15:37 |
Sent To |
PC |
|
| Notes |
| 2008-03-05 15:52:48 | REV 18 PAGES M0.00, M2.01, M2.02, M2.04, M2.05 | | | PAGE M2.03 HAS A NEW FUEL STORAGE TANK ADDED AND IS | | | REQUIRED TO BE SUBMITTED TO PALM BEACH COUNTY DERM. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
21 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-03-04 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-03-04 |
Time |
13:59 |
Sent To |
PC |
|
| Notes |
| 2008-03-04 14:00:52 | SMOKE CONTROL RATIONAL ANALYSIS REPORT BY WCIS | | | CONSULTING, LLC. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
20 |
Status |
P |
Date |
2008-03-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-03-05 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-03-04 |
Time |
09:23 |
Sent To |
PC |
|
| Notes |
| 2008-03-04 13:59:45 | REVISION 17 OK ALL PAGES EXCEPT M2.03. | | | M2.03 REQUIRES SUBMITTAL TO PALM BEACH COUNY DERM. | | | PAGES M2.01, M2.02, M2.04 AND M2.05 WERE SUPERCEDED BY | | | REVISION 18 AND ARE MARKED "SEE REVISED" | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
19 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-02-26 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-02-26 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2008-02-26 17:40:47 | SUBMITTAL # 15.500.003 SMOKE FIRE DAMPERS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
18 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-02-26 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-02-26 |
Time |
17:08 |
Sent To |
|
|
| Notes |
| 2008-02-26 17:11:20 | SUBMITTAL # 15-700-008 MITSUBISHI A/C |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
17 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-02-26 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-02-26 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2008-02-26 16:55:35 | SUBMITTAL # 15-700-009 DAIKINA/C UNITS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
16 |
Status |
|
Date |
2008-02-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-02-13 |
Time |
07:19 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-02-13 |
Time |
07:19 |
Sent To |
|
|
| Notes |
| 2008-02-13 07:21:43 | SUBMITTAL # 15-700-006 AIR DISTRIBUTION |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
15 |
Status |
P |
Date |
2008-02-12 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2008-02-12 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2008-02-12 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2008-02-12 16:24:28 | SUBMITTLE # 15.700.013 ACME FANS | | | SUBMITTLE # 15.700.010 WALL VENTS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
14 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-01-22 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-01-22 |
Time |
15:39 |
Sent To |
PC |
|
| Notes |
| 2008-01-22 15:40:18 | SUBMITTAL #15-700.011 MITSUBISHI MINI-SPLIT UNITS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
13 |
Status |
P |
Date |
2008-01-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-01-22 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-01-22 |
Time |
14:50 |
Sent To |
PC |
|
| Notes |
| 2008-01-22 15:39:11 | SUBMITTAL #15-500.005 FIRE/SMOKE DAMPERS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
12 |
Status |
F |
Date |
2007-12-18 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-12-18 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-12-12 |
Time |
15:49 |
Sent To |
PC |
|
| Notes |
| 2007-12-18 09:19:33 | REVIEW #: REV.16 | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | PAGES RELATED TO OUTSTANDING REVIEW COMMENTS WHICH HAVE | | | NOT BEEN ADDRESSED WILL NOT BE STAMPED UNTIL ALL | | | OUTSTANDING ISSUES ARE ADDRESSED. PLEASE SEE REVIEW | | | COMMENTS PUBLISHED ON 6/26/07 AND 10/21/07. | | | | | | 1 THROUGH 4: OK FROM PREVIOUS REVIEW. | | | | | | 5. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 6. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 7. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 8. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 9 THROUGH 11: OK FROM PREVIOUS REVIEW. | | | | | | 12. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 13. THE MAJORITY OF ISSUES RAISED IN PREVIOUS REVIEWS | | | AS COMMENT #13 HAVE NOT BEEN ADDRESSED. THE NOTE ON | | | M0.00, M2.01, M2.03 CLAIMING NATURAL VENTILATION FOR | | | SMOKE CONTROL UNDER THE 2001 CODE HAS NOT BEEN REMOVED. | | | SEE FBC 403.15 FOR REQUIREMENTS UNDER FBC 2004. THERE | | | HAS BEEN NO RATIONAL ANALYSIS SUBMITTED FOR THE SMOKE | | | CONTROL SYSTEM AS REQUIRED BY FBC 909.2, 909.4 AND FBC, | | | M 513.4, 513.4. NO INFORMATION HAS BEEN PROVIDED | | | REGARDING THE SUITABILITY OF AHU 12 AND RELATED SUPPLY | | | DUCTWORK FOR USE AS PART OF THE SMOKE CONTROL SYSTEM | | | (APPARENTLY) TO DELIVER MAKE-UP AIR. IT WAS REQUESTED | | | IN PREVIOUS REVIEW TO SHOW THESE COMPONENTS TO BE IN | | | COMPLIANCE WITH FBC, M 513.10.2 AND FBC 513.10.5. | | | | | | ALSO, IS MECHANICAL ROOM 051 TO BE USED AS A PLENUM FOR | | | BOTH AIR CONDITIONING AND SMOKE CONTROL MODES? IN SMOKE | | | CONTROL MODE, THIS ROOM APPEARS TO BE SERVING AS AN | | | EXHAUST DUCT. THE SUITABILITY OF THIS ROOM FOR USE AS A | | | PART OF THE SMOKE EXHAUST DUCT SYSTEM SHOULD BE PART OF | | | THE RATIONAL ANALYSIS FOR THE FOLLOWING REASON: AMONG | | | OTHER REQUIREMENTS, 513.10.2 REQUIRES EXHAUST DUCTS TO | | | BE CONSTRUCTED IN ACCORDANCE WITH FBC, M CHAPTER 6. | | | FBC, M 602.2 LIMITS THE USE OF GYPSUM PLENUMS TO | | | SYSTEMS WHERE THE AIR TEMPERATURE DOES NOT EXCEED 125 | | | DEGREES F. | | | NOTE: THESE REQUIREMENTS APPLY TO ALL DUCT AND | | | EQUIPMENT WHICH WILL BE USED AS PART OF THE SMOKE | | | CONTROL SYSTEM, SUCH AS AHUS 13 AND 14. | | | | | | IN ADDITION, THE DESIGN OF THE SUPPLY, RETURN AND | | | EXHAUST DUCT AND DAMPER SYSTEMS RELATED TO SEF-5, | | | SEF-7, AHU-13 AND AHU-14 IS UNCLEAR ON THE PLANS DUE TO | | | THE AMOUNT OF INTERSECTING DUCTS, REFRIGERANT LINES AND | | | WALLS WITHIN THIS SMALL AREA. PLEASE PROVIDE A CLEAR | | | DEPICTION OF THIS AREA (PERHAPS A LARGER SCALE DETAIL | | | OF THIS AREA) TO DISCERN THE DESIGN INTENT IN ORDER TO | | | FACILITATE A COMPLETE REVIEW FOR COMPLIANCE WITH FBC, M | | | 513. | | | NOTE: SEVERAL DUCT PENETRATIONS OF RATED WALL AND | | | FLOOR/CEILING ASSEMBLIES ARE SHOWN TO BE PROTECTED WITH | | | FIRE DAMPERS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC, M 607.2.1. IN ADDITION TO FIRE PROTECTION, | | | DUCTS AND AIR TRANSFER OPENINGS ARE REQUIRED TO BE | | | PROTECTED WITH A MINIMUM CLASS II, 250DEGREE F SMOKE | | | DAMPER COMPLYING WITH THE FLORIDA BUILDING CODE, | | | BUILDING IN ACCORDANCE WITH FBC, M 513.2.1. | | | | | | FURTHERMORE, THE SMOKE CONTROL MAKE-UP AIR INTAKE AND | | | EXHAUST OUTLET LOCATIONS ASSOCIATED WITH SEF-5 AND | | | SEF-7 ARE NOT LOCATED SO AS TO MINIMIZE THE POTENTIAL | | | FOR INTRODUCING SMOKE OR FLAME INTO THE BUILDING. | | | EXHAUST OUTLETS SHALL BE SO LOCATED AS TO MINIMIZE | | | REINTRODUCTION OF SMOKE INTO THE BUILDING IN ACCORDANCE | | | WITH FBC, M 513.10.3. | | | PLEASE ADDRESS ALL THESE ISSUES, WITH SUPPORTING | | | DOCUMENTATION IF APPLICABLE, WHEN RESUBMITTING. | | | | | | 14. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 15. REGARDING SMOKE CONTROL AS SHOWN ON M2.02 AND | | | M2.05, PLEASE SEE COMMENT 13 ABOVE AS ALL RELATED | | | COMMENTS APPLY IN THESE AREAS. FBC, M SEC.513. | | | | | | 16 AND 17: OK | | | | | | 18. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 19. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 20. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | | | | 21. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 22 AND 23: OK | | | | | | 24. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 25. OK | | | | | | 26. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 27. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | NOTE: THE CONDITIONS RELATED TO PREVIOUS COMMENT ALSO | | | APPLY TO PG M2.16. | | | | | | 28. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 29 AND 30: OK | | | | | | 31. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 32. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 33. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 34. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 35. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | NOTE: SEE THE SUPPLY DUCT CROSSING THE CORRIDOR AT | | | MEN?S AND WOMEN?S LOCKER ROOMS. | | | | | | 36. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 37. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 38. OK | | | | | | 39. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | NOTE: SEVERAL PAGES RELATED TO THIS COMMENT WERE NOT | | | RESUBMITTED WITH THIS REVISION. | | | | | | 40. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | NOTE: THE PAGE RELATED TO THIS COMMENT WAS NOT | | | RESUBMITTED WITH THIS REVISION. | | | | | | 41. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | NOTE: SEVERAL PAGES RELATED TO THIS COMMENT WERE NOT | | | RESUBMITTED WITH THIS REVISION. | | | | | | 42 THROUGH 44: OK | | | | | | 45. NO PAGES RELATED TO THIS COMMENT WERE RESUBMITTED. | | | IF THERE ARE NO CHANGES FROM THE PERMIT SET, | | | RESUBMISSION IS NOT NECESSARY. | | | | | | 46. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | 47. OK EXCEPT, M4.01 RISER OAR-4 STILL HAS NO SIZE | | | SHOWN FOR BRANCH OFFS ON MEZZANINE AND GROUND LEVELS. | | | | | | 48 AND 49: OK | | | | | | A: M2.01: BASED ON THE LATEST REVISED ARCHITECTURAL | | | PLANS ON FILE IN THE PERMIT SET (REV.18 DATED 9-18-07), | | | THE LOCATIONS OF FIRE DAMPERS SHOWN ON THIS PAGE STILL | | | DO NOT CORRESPOND WITH THE LOCATIONS OF RATED WALLS. | | | EXAMPLES: 1) 12X12 TRANSFER DUCT FROM COPY 004 TO | | | RECEPTION 004 SHOWS FD IN A NON-RATED WALL. 2) 6 INCH | | | FLEX DUCT ENTERING CONFERENCE 008 THROUGH A RATED WALL | | | WITH NO FD. 3) 12X8 SUPPLY FEEDING RECEPTION 004 SHOWS | | | A FD WHERE THERE IS NO WALL OF ANY KIND. THERE ARE | | | SEVERAL OTHER LOCATIONS. PLEASE CHECK THE ENTIRE AREA | | | AND COORDINATE LOCATIONS OF REQUIRED FIRE DAMPERS WITH | | | LOCATIONS OF RATED WALLS ON ARCHITECTURAL PLANS. DO NOT | | | SHOW FDS IN NON-RATED WALLS AS THEY WOULD NOT BE | | | INSTALLED IN ACCORDANCE WITH THEIR LISTING AS REQUIRED | | | BY FBC, M 607.2. | | | | | | B. OK | | | | | | C. OK | | | | | | D. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | E. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | F. M2.04: SEF-5 DUCT (AND POSSIBLY SEF-7 DUCT) STILL | | | SHOWS FIRE DAMPERS. SHOW OPENING PROTECTIVES WHICH ARE | | | IN COMPLIANCE WITH FBC, M 607.2.1. | | | | | | G. M2.06: O.A. DUCT HAS BEEN ADDED. HOWEVER, O.A. RATE | | | FOR AHU ST-11 IS NOT SHOWN ON EQUIPMENT SCHEDULE. SEE | | | M-5.01. ALSO, VENTILATION SYSTEMS SHALL BE DESIGNED TO | | | BE CAPABLE OF REDUCING THE SUPPLY OF OUTDOOR AIR TO THE | | | MINIMUM VENTILATION RATES REQUIRED BY SECTION 6.1.3 OF | | | ASHRAE 62 IN COMPLIANCE WITH FBC 13-409.1.ABC.1.1. | | | THERE IS NO VOLUME DAMPER ON O.A. DUCT. | | | | | | H. THIS HAS GENERALLY BEEN CORRECTED. HOWEVER, ON M2.07 | | | AND M2.08 THE C.O. SENSORS HAVE A DESIGNATION FOR | | | ?GEF-5&R.? PLEASE SHOW A DESIGNATION WHICH CORRESPONDS | | | WITH THE FANS SERVING THE FLOOR WHERE THE C.O. SENSORS | | | ARE LOCATED. | | | | | | I. OK | | | | | | J. O.A. RATES FOR AHU 18 IS NOW ON PLANS. HOWEVER, | | | COOLING LOAD CALCS, AS PREVIOUSLY REQUESTED, WERE NOT | | | PROVIDED AS REQUIRED BY FBC 13-407.1.ABC.1. ALSO, THE | | | ENERGY CALCULATION FORM SUBMITTED IS NOT THE CORRECT | | | VERSION. AS THIS PERMIT APPLICATION WAS SUBMITTED PRIOR | | | TO DEC. 8, 2006 THE CORRECT FORM IS 400A V2.11. IN | | | ADDITION, THE ADDRESS ON THE PROJECT SUMMARY SHEET IS | | | INCORRECTLY STATED AS 430 HIBISCUS, RATHER THAN THE | | | PERMITTED ADDRESS OF 480 HIBISCUS. PLEASE ALSO SEE THAT | | | THE OWNER/AGENT HAS NOT SIGNED THE FORM AS REQUIRED BY | | | FBC 13-103.1. PLEASE MAKE ALL NECESSARY CORRECTIONS AND | | | RESUBMIT ENERGY CALCULATIONS. | | | | | | K. OK | | | | | | L.PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | NOTE: PG M2.33 WAS NOT RESUBMITTED WITH REV.16. | | | | | | M. OK EXCEPT, M2.31 WAS NOT RESUBMITTED WITH REV.16. | | | THE CURRENT M2.31 (REV.4) SHOWS THE RELIEF VENT FOR | | | STAIR #3 AS 36X36 WHILE THE RISER DIAGRAM FOR STAIR #3 | | | ON M4.03 (REV.16) SHOWS THE RELIEF VENT AS 18X18. WHICH | | | IS CORRECT? PLEASE CLARIFY. | | | | | | N. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | O. OK. HAVE THESE SHAFT ENCLOSURES BEEN INCORPORATED | | | INTO THE ARCHITECTURAL PLANS? | | | | | | P. THIS PAGE WILL BE REVIEWED IN CONJUNCTION WITH | | | RESUBMITTED ENERGY CALCULATIONS. | | | | | | Q. COMMENT 33(A) WAS NOT ADDRESSED. | | | | | | R. M6.02 WAS NOT RESUBMITTED AS PART OF REV.16. | | | | | | S. OK | | | | | | T. OK | | | | | | U. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | V. PREVIOUS COMMENT(S) NOT ADDRESSED IN WRITING OR ON | | | PLANS. SHOW ALL REQUIRED/REQUESTED INFORMATION AND | | | COMPLIANCE WITH CITED CODE SECTION AS STATED IN | | | PREVIOUS REVIEW COMMENTS. | | | | | | NOTE: REVISIONS TO MECHANICAL PLANS CONTINUE TO BE | | | ADDED WITHOUT PREVIOUS REVIEW COMMENTS BEING ADEQUATELY | | | ADDRESSED. THESE CHANGES HAVE NOT BEEN INCORPORATED | | | INTO THE PERMIT SET OF PLANS. WE ARE NOW AT A POINT | | | WHERE IT BECOMES IMPRACTICAL TO REVIEW FOR CHANGES | | | UNTIL ALL OUTSTANDING REVIEW COMMENTS HAVE BEEN | | | ADDRESSED AND THE RELATED CODE DEFICIENCIES ARE | | | CORRECTED. NO FURTHER CHANGES TO MECHANICAL PLANS WILL | | | BE REVIEWED UNTIL ALL OUTSTANDING COMMENTS HAVE BEEN | | | ADEQUATELY ADDRESSED. | | | | | | AS THE ABOVE COMMENTS INDICATE, THE MAJORITY OF | | | PREVIOUS REVIEW COMMENTS ARE STILL OUTSTANDING. PLEASE | | | PROVIDE A WRITTEN RESPONSE TO EACH COMMENT WITH A | | | DESCRIPTION OF HOW EACH COMMENT HAS BEEN ADDRESSED. | | | THIS WILL HELP TO FACILITATE A TIMELY REVIEW. ONE SET | | | OF REV.16 PLANS WILL BE RETAINED BY THIS OFFICE FOR THE | | | PURPOSE OF DOCUMENTING REPEAT CODE DEFICIENCIES AND TO | | | ASSIST IN IDENTIFYING CHANGES DURING SUBSEQUENT | | | REVIEWS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
11 |
Status |
F |
Date |
2007-10-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-10-21 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-10-10 |
Time |
17:02 |
Sent To |
|
|
| Notes |
| 2007-10-21 17:04:17 | REV.13 AND REV.15 | | | | | | FBC 2004 CODE FAMILY W/ 2005 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING PAGES WERE REVIEWED FOR CODE COMPLIANCE | | | WITH ONE COPY RETAINED TO BE INCLUDED IN PERMIT SET OF | | | PLANS: | | | M2.09 | | | M2.12 | | | M2.15 | | | M2.18 | | | M2.21 | | | M2.24 | | | M2.27 | | | M2.30 | | | M6.01 | | | | | | THE REMAINING PAGES FROM REV.13 AND REV.15 ARE DENIED | | | AND RETURNED WITH COMMENTS TO FOLLOW. TWO DIFFERENT | | | SETS OF REVISIONS WERE SUBMITTED FOR REVIEW: REV.13 AND | | | REV.15. PAGES M0.00, 2.01, 2.04, 2.31, 2.32, 5.02 HAVE | | | BEEN REMOVED FROM REV.13 SUBMITTAL AND REPLACED BY | | | REV.15. ALL CHANGES FROM BOTH REVISIONS WILL BE | | | COMPARED TO THE PERMIT PLANS AND BE REVIEWED FOR CODE | | | COMPLIANCE AS WELL AS FOR RESPONSES TO PREVIOUS REVIEW | | | COMMENTS DATED 6/26/07. | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. NEW COMMENTS | | | GENERATED BY ADDITIONAL CHANGES IN THESE REVISIONS WILL | | | APPEAR AT THE END OF REVIEW AND BE GIVEN LETTER, RATHER | | | THAN NUMBER, DESIGNATIONS. | | | | | | 1 THROUGH 4: OK | | | | | | 5. M2.01: NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5. | | | | | | 6. M2.01: PROVIDE WALL MOUNTING DETAIL WHICH WORKS IN | | | CONJUNCTION WITH MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS RELATED TO AIRFLOW AND SERVICE CLEARANCES. | | | FBC,M 303.1 AND 303.4 | | | | | | 7. M2.02: A) NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5. | | | B) PROVIDE WALL MOUNTING DETAIL WHICH WORKS IN | | | CONJUNCTION WITH MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS RELATED TO AIRFLOW AND SERVICE CLEARANCES. | | | FBC,M 303.1 AND 303.4 | | | | | | 8. M2.02: THE DESIGNATION OF THIS ROOM HAS BEEN CHANGED | | | TO "STORAGE 014" ON PG A1.1. PLEASE COORDINATE | | | DRAWINGS. FBC 106.1.1. | | | | | | 9 THROUGH 11: OK | | | | | | 12. M2.04: NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5. | | | | | | 13. M2.04: A) WRITTEN RESPONSE FROM DESIGNER (DRAFTED | | | 8/7/07, PRIOR TO THIS REVISION) INDICATES "NATURAL | | | VENTILATION" WILL BE USED FOR THE REMOVAL OF SMOKE IN | | | THE LOBBY AREA. HOWEVER, M2.04 SHOWS PORTIONS OF THE | | | LOBBY AREA PROVIDED WITH MECHANICAL SMOKE CONTROL | | | PROVIDED BY THE EXHAUST METHOD. SMOKE CONTROL NOTE ON | | | M0.00 AND M2.01 IS CLAIMING 412.5 OF THE 2001 FBC FOR | | | USE OF "NATURAL VENTILATION" AS SMOKE CONTROL. THAT | | | CODE SECTION IS NOT APPLICABLE TO THIS PERMIT AS THIS | | | JOB IS UNDER THE 2004 FBC W/ 2005 REVISIONS. UNDER THIS | | | CODE, FBC 403.15 (HIGH RISE BUILDINGS) REQUIRES SMOKE | | | CONTROL BE PROVIDED IN ACCORDANCE WITH FBC SEC.909. | | | THIS SECTION ALLOWS FOR THREE POSSIBLE METHODS OF SMOKE | | | CONTROL. SEE FBC 909.6 THROUGH 909.8. GIVEN THAT A | | | "NATURAL VENTILATION" METHOD IS NOT LISTED IN THE 2004 | | | FBC, THERE ARE SEVERAL AREAS OF THE BUILDINGWHICH ARE | | | NOT PROVIDED WITHSMOKE CONTROL. SHOW ON PLANS HOW | | | AREAS PREVIOUSLY COVERED BY "NATURAL" MEANS WILL NOW BE | | | COVERED AS REQUIRED BY FBC 909. HAS A RATIONAL ANALYSIS | | | FOR THE SYSTEM BEING USED BEEN PREPARED AND SUBMITTED | | | AS PART OF THE PERMIT RECORD? PLEASE SEE FBC 909.2 AND | | | 909.4 FOR SPECIFIC REQUIREMENTS. | | | B) IS AHU 12 AND RELATED SUPPLY DUCTWORK TO BE USED AS | | | PART OF THE SMOKE CONTROL SYSTEM FOR THE LOBBY AREA? | | | DUCTS SHALL BE CONSTRUCTED TO MEET THE REQUIREMENTS OF | | | FBC,M 513.10.2 AND FANS SHALL COMPLY WITH FBC,M | | | 513.10.5. SHOW COMPLIANCE WITH THESE SECTIONS. | | | | | | 14. M2.05: NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5. | | | | | | 15. M2.05: SEE COMMENT 13 ABOVE RELATED TO SMOKE | | | CONTROL REQUIREMENTS. | | | | | | 16 AND 17: OK | | | | | | 18. M2.07: NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5. | | | | | | 19. M2.07: 24X8 SMOKE EXHAUST DUCTS FROM RISER SE-1 ON | | | FLOOR PLAN WITH FIRE DAMPERS AT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 20. M2.08: NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5 INCLUDING FOR CU-19. ALSO, PROVIDE WALL | | | MOUNTING DETAIL WHICH WORKS IN CONJUNCTION WITH | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS RELATED TO | | | AIRFLOW AND SERVICE CLEARANCES. FBC,M 303.1 AND 303.4 | | | | | | 21. M2.08: SE-2 AND SE-3 INTAKE AND OA-4 OUTLET DUCTS | | | ARE SHOWN WITH FIRE DAMPERSAT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 22 AND 23: OK | | | | | | 24. M2.10: A) NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5. | | | B) 24X8 SMOKE EXHAUST DUCTS FROM RISER SE-1 ON FLOOR | | | PLAN WITH FIRE DAMPERS AT RATED WALL PENETRATIONS. | | | WHERE THE INSTALLATION OF A FIRE DAMPER WILL INTERFERE | | | WITH THE OPERATION OF A REQUIRED SMOKE CONTROL SYSTEM | | | IN ACCORDANCE WITH SECTION 513, APPROVED ALTERNATIVE | | | PROTECTION SHALL BE UTILIZED IN ACCORDANCE WITH FBC,M | | | 607.2.1. | | | | | | 25. OK | | | | | | 26. M2.11: SE-2 AND SE-3 INTAKE AND OA-4 OUTLET DUCTS | | | ARE SHOWN WITH FIRE DAMPERSAT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 27. M2.13: NO BOLLARDS ARE SHOWN ON MECHANICAL OR | | | ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH FBC,M 303.4 | | | AND 304.5. ALSO, 24X8 SMOKE EXHAUST DUCTS FROM RISER | | | SE-1 ON FLOOR PLAN WITH FIRE DAMPERS AT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 28. M2.14 AND M2.17: NO BOLLARDS ARE SHOWN ON | | | MECHANICAL OR ARCHITECTURAL PLANS. SHOW COMPLIANCE WITH | | | FBC,M 303.4 AND 304.5 INCLUDING FOR CU-19. ALSO, SE-2 | | | AND SE-3 INTAKE AND OA-4 OUTLET DUCTS ARE SHOWN WITH | | | FIRE DAMPERSAT RATED WALL PENETRATIONS. WHERE THE | | | INSTALLATION OF A FIRE DAMPER WILL INTERFERE WITH THE | | | OPERATION OF A REQUIRED SMOKE CONTROL SYSTEM IN | | | ACCORDANCE WITH SECTION 513, APPROVED ALTERNATIVE | | | PROTECTION SHALL BE UTILIZED IN ACCORDANCE WITH FBC,M | | | 607.2.1. | | | | | | 29 AND 30: OK | | | | | | 31. M2.17: PROVIDE DETAIL AND LISTED ASSEMBLY | | | (THROUGH-PENETRATION FIRESTOP SYSTEM) TO BE USED FOR | | | TYPE-B FLUE PIPE. ALSO, FIRE DAMPER FOR EXHAUST DUCT IS | | | NOT SHOWN ON PLANS. SEE FBC,M 607.8. | | | | | | 32. M2.17: BOILER ROOM CALCULATIONS CALL FOR 1 SQ.IN. | | | PER 2000 BTU/H. THIS METHOD REQUIRES TWO PERMANENT | | | OPENINGS COMMUNICATING DIRECTLY WITH THE OUTDOORS, EACH | | | WITH MIN. 525 SQ.IN. FREE AREA, BASED ON TH 1,050,000 | | | TOTAL BTU/H SHOWN ON PLAN. SEE FBC.FG 304.6.1. FLOOR | | | PLAN SHOWS ONE 36X12 LOUVER WHICH DOES NOT COMMUNICATE | | | WITH THE OUTDOORS SINCE IT IS LOCATED INSIDE AN | | | ENCLOSED PARKING GARAGE. | | | | | | 33. A) BOILER ROOM FLOOR PLAN SHOWS THREE FANS. NONE OF | | | THESE FANS ARE LISTED ON EQUIPMENT SCHEDULE. HOW DO | | | THESE FANS WORK IN CONJUNCTION WITH COMBUSTION AIR | | | REQUIREMENTS? MECHANICAL COMBUSTION AIR IS NOT | | | INDICATED IN BOILER ROOMCALCULATIONS. IF MECHANICAL | | | COMBUSTION AIR IS TO BE USED, IT SHALL BE DESIGNED IN | | | ACCORDANCE WITH FBC,FG 304.9. SHOW ALL RELEVANT | | | CALCULATIONS AND REQUIRED CONTROLS IF APPLICABLE. B) EF | | | "EXHAUSTO BESB" ATTACHED TO 12 INCH ROUND DUCT GOES TO | | | 36X30 LOUVER. FLOOR PLAN INDICATES THIS IS AN INTAKE | | | LOUVER. IS THIS AN INTAKE OR EXHAUST SYSTEM? IF IT IS | | | EXHAUST, IT SHALL BE AT LEAST 10 FEET FROM GARAGE | | | INTAKE LOUVERS IN ACCORDANCE WITH FBC,M 401.5.1 AND IT | | | SHALL BE ORIENTED SO AS NOT TO BE READILY DRAWN IN BY | | | GARAGE VENTILATION SYSTEM IN ACCORDANCE WITH FBC,M | | | 501.2. | | | C) FLOOR PLAN AT BOILER ROOM WALL CALLS FOR "HIGH TEMP" | | | FIRE DAMPERS IN EXHAUST DUCTS. WHAT IS TO BE THE DESIGN | | | TEMPERATURE OF THE ACTUATING DEVICES? WHAT IS TO BE THE | | | NORMAL AIR TEMPERATURE WITHIN THE DUCTS? THE OPERATING | | | TEMPERATURE SHALL BE APPROXIMATELY 50 DEG.F ABOVE THE | | | NORMAL TEMPERATURE WITHIN THE DUCT SYSTEM, BUT NOT LESS | | | THAN 160 DEG.F IN ACCORDANCE WITH FBC,M 607.3.1.1(1). | | | SHOW EXPECTED AIR TEMPERATURE AND REQUIRED TEMPERATURE | | | SETTING FOR FIRE DAMPER ACTUATING DEVICES (FUSIBLE | | | LINKS). FBC 106.1.2 | | | | | | 34. M2.19: 24X8 SMOKE EXHAUST DUCTS FROM RISER SE-1 ON | | | FLOOR PLAN WITH FIRE DAMPERS AT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 35. M2.19: ALL DUCT PENETRATIONS OF FIRE RESISTANCE | | | RATED CORRIDORS SHALL BE PROTECTED WITH SMOKE DAMPERS | | | IN ACCORDANCE WITH FBC,M 607.5.4. SEE ALSO FBC 715.3.3. | | | SMOKE DAMPERS SHALL BE ACTUATED BY ONE OF THE | | | PRESCRIBED METHODS LISTED UNDER FBC,M 607.5.4.1. | | | | | | 36. M2.19: REFRIGERANT LINES FOR AHU-17 ARE STILL NOT | | | SHOWN ON PLANS. SHOW ROUTING OF REFRIGERANT LINES ON | | | PLANS. FBC 106.1.1. | | | | | | 37. M2.19: 24X8 SMOKE EXHAUST DUCTS FROM RISER SE-1 ON | | | FLOOR PLAN WITH FIRE DAMPERS AT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 38. OK | | | | | | 39. M2.20, 2.23, 2.26, 2.29: SE-2 AND SE-3 INTAKE AND | | | OA-4 OUTLET DUCTS ARE SHOWN WITH FIRE DAMPERSAT RATED | | | WALL PENETRATIONS. WHERE THE INSTALLATION OF A FIRE | | | DAMPER WILL INTERFERE WITH THE OPERATION OF A REQUIRED | | | SMOKE CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, | | | APPROVED ALTERNATIVE PROTECTION SHALL BE UTILIZED IN | | | ACCORDANCE WITH FBC,M 607.2.1. | | | | | | 40. M2.22: 24X8 SMOKE EXHAUST DUCTS FROM RISER SE-1 ON | | | FLOOR PLAN WITH FIRE DAMPERS AT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 41. M2.25, 2.28: 24X8 SMOKE EXHAUST DUCTS FROM RISER | | | SE-1 ON FLOOR PLAN WITH FIRE DAMPERS AT RATED WALL | | | PENETRATIONS. WHERE THE INSTALLATION OF A FIRE DAMPER | | | WILL INTERFERE WITH THE OPERATION OF A REQUIRED SMOKE | | | CONTROL SYSTEM IN ACCORDANCE WITH SECTION 513, APPROVED | | | ALTERNATIVE PROTECTION SHALL BE UTILIZED IN ACCORDANCE | | | WITH FBC,M 607.2.1. | | | | | | 42 THROUGH 44: OK | | | | | | 45. M3.01A THROUGH M3.03F: ALL OF THESE PAGES ARE | | | MARKED AS PART OF REV. 13 BUT THERE ARE NO AREAS ON | | | PLANS MARKED ANS HAVING BEEN REVISED. WITHOUT ANY | | | INDICATION OF CHANGES, THESE PAGES WILL NOT BE | | | REVIEWED. | | | | | | 46. M4.01: RISERS 2A,2B,3A,3B SHOW TYPICAL OUTLET SIZES | | | OF 12X6. HOWEVER, FLOOR PLANS SHOW THESE OUTLETS TO BE | | | 8X6. COORDINATE RISER PLANS WITH FLOOR PLANS AND | | | RESUBMIT. | | | | | | 47. M4.02: OA-4 RISER SHOWS ONE OUTLET WITH ONE FSD AND | | | NO SIZE AT MEZZANINE AND GROUND LEVELS. FLOOR PLAN ON | | | MEZZANINE LEVEL SHOWS TWO OUTLETS WITH TWO FSD'S. | | | COORDINATE FLOOR PLANS AND RISER PLANS. ALSO, SHOW | | | SIZES OF ALL RISER INLETS AND OUTLETS WHICH DO NOT | | | MATCH THE "TYPICAL" DESIGNATION. | | | | | | 48 AND 49: OK | | | | | | NEW COMMENTS: | | | | | | A. M2.01: THROUGHOUT THIS FLOOR PLAN THERE ARE | | | UNPROTECTED OPENINGS IN RATED WALLS, FIRE DAMPERS IN | | | NON-RATED WALLS AND FIRE DAMPERS WHERE THERE ARE NO | | | WALLS. COORDINATE THE LOCATIONS OF REQUIRED OPENING | | | PROTECTIVES WITH THE LOCATIONS OF RATED WALL ASSEMBLIES | | | AS SHOWN ON ARCHITECTURAL PLANS. SHOW OPENING | | | PROTECTIVES WHERE THEY ARE REQUIRED AND REMOVE THEM | | | WHERE THEY ARE NOT. FBC,M 607.8 | | | | | | B. M2.01: A TRANSFER DUCT HAS BEEN ADDED TO COPY ROOM | | | 004 FOR BALANCED RETURN BUT HAS NOT BEEN ADDED FOR | | | OFFICE 004, WHICH IS A HABITABLE ROOM REQUIRING | | | BALANCED RETURN IN ACCORDANCE WITH FBC,M 601.4. SHOW | | | COMPLIANCE AND RESUBMIT. | | | | | | C. M2.XX: THE SYMBOL "EM" HAS BEEN ADDED TO SEVERAL | | | PAGES, BUT THS SYMBOL HAS NOT BEEN ADDED TO | | | ABBREVIATION OR SYMBOL LEGENDS ON M0.00. PLEASE CLARIFY | | | THE MEANING OF THE ABBREVIATION/SYMBOL. FBC 106.1.1 | | | | | | D. M2.03: BASED ON FLOOR PLAN A1.2, THERE ARE SOME | | | DUCTS SHOWN PENETRATING RATED WALL ASSEMBLIES. | | | COORDINATE WITH ARCHITECTURAL PLANS AND SHOW OPENING | | | PROTECTIVES AT ALL DUCT PENETRATIONS OF RATED WALLS IN | | | ACCORDANCE WITH FBC,M 607.5. | | | | | | E. M2.03: IS THE SUPPLY A/C SYSTEM TO ALSO SERVE AS | | | MAKE-UP AIR FOR THE SMOKE CONTROL OF THE SOUTH BLOCK? | | | IF SO, DUCTS SHALL BE CONSTRUCTED TO MEET THE | | | REQUIREMENTS OF FBC,M 513.10.2 AND AHU-16 SHALL BE | | | DESIGNED TO MEET THE REQUIREMENTS OF FBC,M 513.10.5. | | | | | | F. M2.03: SOME AREAS IN AND AROUND LOBBY ARE PROTECTED | | | BY FIRE RESISTANCE RATED ASSEMBLIES SUCH AS WALLS AND | | | POSSIBLY CEILINGS. DUCTS ARE SHOWN PENETRATING SUCH | | | ASSEMBLIES WITHOUT OPENING PROTECTIVES AS REQUIRED BY | | | FBC,M 607.5. EXAMPLE: 6X6 DUCT FEEDING THE FIRE COMMAND | | | ROOM. SHOW PENETRATIONS TO BE PROTECTED AS REQUIRED BY | | | THIS SECTION. COORDINATE WITH ARCHITECTURAL PLANS. | | | ALSO, SEF-5 DUCT IS SHOWN WITH MULTIPLE FIRE DAMPERS. | | | WHERE THE INSTALLATION OF A FIRE DAMPER WILL INTERFERE | | | WITH THE OPERATION OF A REQUIRED SMOKE CONTROL SYSTEM | | | IN ACCORDANCE WITH SECTION 513, APPROVED ALTERNATIVE | | | PROTECTION SHALL BE UTILIZED IN ACCORDANCE WITH FBC,M | | | 607.2.1. | | | | | | G. M2.06: WHAT IS THE SOURCE OF VENTILATION FOR STORAGE | | | AREAS? NOTE: STORAGE ROOMS FOR RETAIL STORES AND SALES | | | FLOORS ARE REQUIRED TO HAVE VENTILATION AT A RATE OF | | | 0.15 CFM PER SQ.FT IN ACCORDANCE WITH FBC,M TABLE 403.3 | | | AND ASHRAE 62-2001 TABLE 2.1. | | | | | | H. M2.04 THROUGH M2.17: FLOOR PLAN INDICATES EACH C.O. | | | SENSOR IS DESIGNATED FOR ONE GARAGE FAN. GARAGE | | | VENTILATION SCHEDULE SHOWS THAT BOTH FANS ARE REQUIRED | | | TO PROVIDE THE MINIMUM VENTILATION RATE OF 1.5 CFM PER | | | SQ.FT. WHEN CO LEVELS REACH 25 PPM. THEREFORE, IF ANY | | | CO SENSOR ON A FLOOR DETECTS 25 PPM, BOTH FANS ON THAT | | | FLOOR SHOULD BE ACTUATED. SHOW COMPLIANCE WITH FBC,M | | | SEC.404. | | | | | | I. M2.19: WOMEN'S LOCKER ROOM, FLOOR PLAN SHOWS 220 CFM | | | SUPPLY AIR WITH ONLY 120 CFM OF EXHAUST. ALL AIR | | | SUPPLIED TO SUCH SPACES SHALL BE EXHAUSTED IN | | | ACCORDANCE WITH FBC,M 403.2.1(3). SHOW EXHAUST TO BE | | | EQUAL OR GREATER THAN THE AIR BEING SUPPLIED TO THESE | | | SPACES. ALSO, FAN SCHEDULE ON M5.02 SHOWS TEF 1-4 | | | CONTROLLED BY SWITCH. SHOW HOW THIS WILL ENSURE ALL AIR | | | SUPPLIED TO THESE SPACES BY AHU-17 IS EXHAUSTED IN | | | ACCORDANCE WITH FBC,M 403.2.1(3). TEF'S MAY BE | | | INTERLOCKED WITH AHU OR RUN CONTINUOUS AS EXAMPLES OF | | | POSSIBLE METHODS OF COMPLIANCE.ALSO, SHOW COMPLIANCE | | | WITH FBC,M 401.3. | | | | | | J. M2.20: AHU/CU 18 IS NEW TO PLANS. SHOW THE O.A. RATE | | | ON SHCEDULE (M5.01). ALSO, PROVIDE COOLING LOAD | | | CALCULATIONS OR SYSTEM SIZING SUMMARY AS PART OF | | | REVISED ENERGY CALCULATIONS IN ACCORDANCE WITH FBC | | | 13-407.1.ABC.1. | | | | | | K. M2.20: FLOOR PLAN SHOWS 75 CFM SUPPLY IN HEALTH CLUB | | | TOILET ROOMS WITH ONLY 50 CFM OF EXHAUST. ALL AIR | | | SUPPLIED TO SUCH SPACES SHALL BE EXHAUSTED IN | | | ACCORDANCE WITH FBC,M 403.2.1(3). SHOW EXHAUST TO BE | | | EQUAL OR GREATER THAN THE AIR BEING SUPPLIED TO THESE | | | SPACES. ALSO, FAN SCHEDULE ON M5.02 SHOWS TX-1 | | | CONTROLLED BY SWITCH. SHOW HOW THIS WILL ENSURE ALL AIR | | | SUPPLIED TO THESE SPACES BY AHU-18 IS EXHAUSTED IN | | | ACCORDANCE WITH FBC,M 403.2.1(3). TX'S MAY BE | | | INTERLOCKED WITH AHU OR RUN CONTINUOUS AS EXAMPLES OF | | | POSSIBLE METHODS OF COMPLIANCE.ALSO, SHOW COMPLIANCE | | | WITH FBC,M 401.3. | | | | | | L. M2.33: KITCHEN EXHAUST GREASE DUCT, WHY IS IT | | | TERMINATING AT A WALL WITH A PLENUM AND LOUVER? GREASE | | | DUCT TERMINATIONS SHALL COMPLY WITH FBC,M 506.3.12. | | | ALSO, PROVIDE DETAIL FOR SUPPORT OF HORIZONTAL AND | | | VERTICAL SECTIONS OF GREASE DUCTS IN ACCORDANCE WITH | | | FBC,M 506.3.3. PROVIDE SUBMITTAL/INSTALLATION | | | INSTRUCTIONS FOR 2-HOUR RATED DUCT WRAP SYSTEM TO BE | | | USED. | | | | | | M. M4.03: RISER PLAN AND ROOF PLANS DO NOT CORRELATE. | | | IT APPEARS THAT SPF 4 AND SPF 3 HAVE BEEN REVERSED. | | | ALSO, ROOF PLAN ON M2.31 DOES NOT SHOW ANY BAROMETRIC | | | OR RELIEF DAMPERS AS SHOWN ON RISER PLAN. PLEASE | | | CORRECT. | | | | | | N. M4.03: STAIR SHAFTS ARE SHOWN WITH RELIEF DAMPERS | | | SET TO 0.05" W.G. HOW WILL THESE WORK TO ACHIEVE THE | | | REQUIRED PRESSURIZATION LEVEL OF 0.15" TO 0.35" AS | | | SHOWN IN FBC 909.20.5? IF THIS IS THE INTENDED DESIGN, | | | SHOW JUSTIFICATION WITHIN THE SMOKE CONTROL RATIONAL | | | ANALYSIS AS REQUIRED BY FBC 909.4. | | | | | | O. M4.04: THIS PAGE HAS A TABLE IN THE UPPER RIGHT | | | CORNER WHICH IS NOT LEGIBLE. PROVIDE THIS TABLE IN A | | | LEGIBLE FORM AND RESUBMIT. FBC 106.1.1 AND 106.1.3. | | | | | | P. M5.01: CHANGES ON THIS PAGE WILL BE REVIEWED WHEN | | | SUBMITTED WITH REVISED ENERGY CALCULATIONS REFLECTING | | | EQUIPMENT CHANGES SHOWN ON PLAN. SEE COMMENT K. | | | | | | Q. M5.02: THIS PLAN WILL BE REVIEWED IN CONJUNCTION | | | WITH RESPONSES TO COMMENTS 33(A), I AND K, WHICH MAY | | | EFFECT THE EXHAUST FAN SCHEDULE AND CONTROLS. | | | | | | R. M6.02: THE THROUGH-PENETRATION FIRESTOP SYSTEM HAS | | | BEEN REPLACED BUT IT IS OF POOR VISUAL QUALITY AND IS | | | NOT LEGIBLE. PLEASE CORRECT AND RESUBMIT. | | | | | | S. M7.01: NOTE 1-D HAS BEEN DELETED FROM PAGE. PLEASE | | | SEE COMMENTS I AND K AND PROVIDE CONTROL INFO AS NEEDED | | | TO CORRELATE WITH THOSE CONDITIONS. | | | | | | T. M7.01: SEE COMMENT H REGARDING GARAGE EXHAUST FAN | | | CONTROLS. | | | | | | U. M7.01: CORRIDOR PRESSURIZATION NOTE D CALLS FOR THE | | | FLOOR OF INCIDENCE TO BE PRESSURIZED. THIS APPEARS TO | | | BE COUNTER TO THE INTENT OF THE PRESSURIZATION METHOD | | | OF SMOKE CONTROL AS STATED IN FBC 909.6. PROVIDE | | | RATIONAL ANALYSIS WHICH CORRESPONDS WITH SEQUENCE OF | | | OPERATION SHOWING HOW SMOKE CONTROL SYSTEM IS TO | | | FUNCTION. SEE FBC 909.2 AND 909.4. | | | | | | V. M7.01: STAIL PRESSURIZATION NOTE B, PRESSURES SHALL | | | BE IN ACCORDANCE WITH FBC 909.20.5. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
10 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-14 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-10 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2007-08-14 10:57:09 | SUBMITTAL WITH NEW REFRIGERANT RISER CALCULATIONS, | | | SHOWING LOCATIONS OF REQUIRED SHAFTS BASED ON | | | REFRIGERANT QUANTITIES AND THE THROUGH-PENETRATION | | | FIRESTOP SYSTEMS TO BE USED WHERE SHAFTS WILL NOT BE | | | REQUIRED. ONLY ONE COPY HAS BEEN SUBMITTED. THEREFORE, | | | IT WILL BE RETAINED PENDING RECEIPT OF REVISED PLANS | | | SHOWING LOCATION OF SHAFTS. AT THAT TIME, THE SUBMITTAL | | | WILL BE USED TO ENSURE THAT SHAFT LOCATIONS ARE ORRECT | | | IN CONJUNCTION WITH RISER CALCULATIONS IN THE | | | SUBMITTAL. | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] | | 2007-08-10 13:52:38 | REFRIGERANT CHASES - UPDATED 8/14/07 | | | | | | 8/13/07 - AS OF THIS TIME, THE SUBMITTAL STATES THAT A | | | DETAIL FOR A TREMCO THROUGH-PENETRATION FIRESTOP SYSTEM | | | IS SINCLUDED IN THE PACKAGE. HOWEVER, NONE COULD BE | | | LOCATED IN THE PACKAGE. A CALL WAS PLACED TO TONY | | | SPEZZA AT THE FELLER OFFICE. TONY SUPPLIED A DETAIL OF | | | A SYSTEM INTENDED FOR USE IN THIS APPLICATION. HOWEVER, | | | THE ASSEMBLY PROVIDED DOES NOT MEET THE F AND T RATING | | | OF THE FLOOR BEING PENETRATED AS IS REQUIRED BY FBC | | | 712.4.1.2. | | | | | | PER THE REQUEST OF JACK NEDLIN, A COPY OF PREVIOUS PLAN | | | REVIEW COMMENTS IS BEING FAXED TO HIS OFFICE. THE | | | REVIEW OF THIS SUBMITTAL IS BEING PLACED ON HOLD, AGAIN | | | AT THE REQUEST OF JACK NEDLIN, UNTIL A RESPONSE IS | | | PROVIDED BY JACK NEDLIN OR OTHER AUTHORIZED AGENT FOR | | | STEVEN FELLER, PE. | | | | | | 8/14/07 - RECEIVED MISSING INFORMATION FROM MARC | | | COLEMAN AT HH DEVELOPMENT. THE SUBMITTAL IS CURRENTLY | | | UNDER REVIEW. | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
9 |
Status |
P |
Date |
2007-07-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-07-14 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-07-14 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2007-07-14 16:12:17 | NEW SHEETS M3.01A THROUGH M3.03F | | | APARTMENT LAYOUTS FOR 2ND THROUGH 7TH FLOORS | | | REVISION OF EQUIPMENT SCHEDULE TO MATCH THESE FLOOR | | | PLANS IS PENDING.\ | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-06-28 |
Time |
19:41 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-06-28 |
Time |
19:31 |
Sent To |
|
|
| Notes |
| 2007-06-28 19:40:32 | RESPONSE TO LETTERS SUBMITTED BY STEVEN FELLER, PE | | | | | | LETTER 1: | | | A) REGARDING THE LETTER RELATED TO REFRIGERANT | | | QUANTITIES, THERE ARE INCONSISTENCIES BETWEEN THE | | | ESTIMATED LINE LENGTHS AND THOSE SHOWN ON PLANS. | | | EXAMPLE 1: RISER 1, 6TH FLOOR HAS AN ESTIMATED LINE | | | LENGTH OF 70 FT. ON THE 6TH FLOOR THERE IS AN | | | ADDITIONAL LENGTH (APPROXIMATELY 20 FT.) OF HORIZONTAL | | | PIPE TO TRAVEL FROM APT A6 TO THE CHASE, WHICH DOES NOT | | | APPEAR TO HAVE BEEN TAKEN INTO ACCOUNT. ALSO ON RISER | | | 1, HOW IS THERE ONLY 20 FEET DIFFERENCE BETWEEN THE 6TH | | | FLOOR AND THE 10TH FLOOR? THAT IS ONLY 5 FEET PER | | | FLOOR. | | | EXAMPLE 2: RISER 4 ON M2.04 SHOWS 43 FT OF HORIZONTAL | | | PIPE WHICH DOES NOT APPEAR TO BE TAKEN INTO ACCOUNT IN | | | THE ESTIMATED LENGTH. ALSO, PLEASE PROVIDE COOLING LOAD | | | CALCULATIONS FOR COMMERCIAL SPACES 1 AND 2 (ACCOUNTING | | | FOR 1ST FLOOR AND MEZZANINE LEVELS) SHOWING 5 TONS TO | | | BE SUFFICIENT FOR FUTURE USE OF THIS SPACE. | | | | | | B) WHY WERE NO CALCULATIONS GIVEN FOR RISER 2? NO SHAFT | | | REQUIREMENT IS SHOWN ON THE CHART ON ANY LEVEL AND IT | | | IS LIKELY TO HAVE A HIGHER QUANTITY OF REFRIGERANT THAN | | | RISER 4. | | | | | | C) PLEASE PROVIDE A BASIS FOR THE REFRIGERANT | | | QUANTITIES USED. THE REFRIGERANT CHARGE QUANTITIES | | | SHOWN ON THE CALCULATIONS APPEAR TO BE BASED ON THE | | | CARRIER MODEL 24ABR, WHICH IS THE EQUIPMENT SHOWN ON A | | | RECENTLY SUBMITTED REVISED EQUIPMENT SCHEDULE. HOWEVER, | | | THE EQUIPMENT SIZES SHOWN IN THE CALCULATIONS REFLECT | | | THOSE ON THE PERMIT SET OF PLANS AND NOT THOSE ON THE | | | REVISED SCHEDULE. PLEASE CLARIFY WHICH INFORMATION IS | | | TO BE USED TO VERIFY THE CALCULATIONS. | | | | | | PLEASE SEE THE LATEST CARRIER LONG-LINE APPLICATION | | | GUIDE WHICH STATES THE FACTORY CHARGE IS FOR THE FIRST | | | 15 FT AND 0.6 OZ SHALL BE ADDED FOR EACH ADDITIONAL | | | FT. | | | | | | NOTE: THE DESIGN OF STARTING THE SHAFT CONSTRUCTION AT | | | THE FLOOR LEVEL WHERE THE REFRIGERANT QUANTITY EXCEEDS | | | THE ASHRAE 15 ALLOWABLE LIMIT IS AGREED TO IN CONCEPT, | | | BUT A MORE ACCURATE DETERMINATION OF WHERE THAT LIMIT | | | IS TO BE REACHED AT EACH RISER IS NEEDED. | | | | | | LETTER 2: | | | THE USE OF A THROUGH-PENETRATION FIRESTOP SYSTEM AS | | | STATED IN FBC 712.4.1.2 IS FOUND TO BE THE CORRECT | | | APPLICATION FOR THE CONDITION WHEN THE REFRIGERANT | | | CHASE IS NOT ENCLOSED IN A SHAFT. HOWEVER, THE DETAILS | | | ON M6.02 OF THE PERMIT SET OF PLANS SHOWS TWO POSSIBLE | | | SYSTEMS, NEITHER OF THEM ARE APPLICABLE TO THE FIELD | | | CONDITIONS UNDER WHICH THEY WOULD BE EMPLOYED. | | | | | | THE FIRST SYSTEM FOR INSULATED PIPE CAN ONLY MEET THE | | | ANNULAR SPACE LIMITATIONS SHOWN IN THE DETAIL IF THERE | | | IS A SINGLE INSULATED PIPE IN A SINGLE, CORRECTLY SIZED | | | FLOOR (OR WALL) OPENING. THE SIZE OF THE PIPE IS | | | LIMITED TO A MAXIMUM OF 1? WHEN IN MANY CASES THE | | | INSULATED PIPE WILL BE 1 1/8? OR POSSIBLY LARGER. | | | PLEASE ALSO NOTE THAT 712.4.1.2 REQUIRES THAT THE | | | THROUGH-PENETRATION FIRESTOP SYSTEM SHALL HAVE AN F AND | | | T RATING NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE | | | REQUIRED RATING OF THE FLOOR BEING PENETRATED. | | | | | | THE SECOND SYSTEM IS LIMITED IN AREA AND CAN NOT HAVE A | | | MAXIMUM DIMENSION OVER 24?. IT IS LIMITED TO A MAXIMUM | | | OF 3 PIPES, NONE OF WHICH ARE SHOWN TO BE INSULATED. | | | THIS SYSTEM ALSO DOES NOT MEET THE T RATING AS REQUIRED | | | BY 712.4.1.2 AS IT STATES THE T RATING AT 0 HOUR. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.671. | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-06-26 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-06-23 |
Time |
15:35 |
Sent To |
|
|
| Notes |
| 2007-06-26 14:27:42 | FBC 2004 CODE FAMILY | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | REVISED MECHANICAL PLANS DATED 5/18/07. THE FOLLOWING | | | PAGES PASSED REVIEW: | | | M2.12, M2.18, M2.21, M2.24, M2.27, M2.30, M2.31, M2.34, | | | M2.35 | | | | | | THE BALANCE OF PAGES SUBMITTED FOR REVISION ARE DENIED. | | | THE FOLLOWING COMMENTS ARE ORGANIZED BY PAGE NUMBER. | | | SOME COMMENTS ARE REFERENCED MORE THAN ONCE IF THE | | | ISSUE IS FOUND ON MORE THAN ONE PAGE. | | | | | | 1. M2.01: THE ACCESS DOOR FOR GEF-1 APPEARS TO BE IN | | | CONFLICT WITH THE FAN HOUSING AND WILL NOT OPEN | | | COMPLETELY. SEE FBC,M 306.5 FOR SERVICE ACCESS | | | REQUIREMENTS. | | | | | | 2. M2.01: THE INTAKE LOUVER FOR GEF-1 IS SHOWN ON PLANS | | | TO BE APPROXIMATELY 7' WIDE. IN ORDER TO ACHIEVE 94 | | | SQ.FT., AS NOTED ON PLANS, THE LOUVER WOULD NEED TO BE | | | OVER 13 FEET TALL. IS THERE SUFFICIENT CLEARANCE? FBC | | | 106.1.2 | | | | | | 3. M2.01, M2.04, M2.07, M2.10, M2.13, M2.16: WHAT ARE | | | THE ACTUAL DIMENSIONS OF THE INTAKE LOUVERS FOR THE | | | GEF'S? WHY IS THE FREE AREA OF THE EXHAUST LOUVERS | | | (23.375 SQ.FT) LESS THAN HALF THE AREA OF THE INTAKE | | | LOUVERS AT THE FANS (51.7 SQ.FT)? ALSO, PLEASE SHOW HOW | | | THE REQUIRED MINIMUM VENTILATION RATE (CONTINUOUS) OF | | | 0.05 CFM PER SQ.FT. IS TO BE PROVIDED IN ACCORDANCE | | | WITH FBC,M 404.2. | | | | | | 4. M2.01: GARAGE VENTILATION NOTE ON PLAN STATES "2 | | | EXHAUST FANS," BUT THIS FLOOR USES ONLY ONE FAN. PLEASE | | | REVISE NOTE SHOWING ONE FAN PROVIDING 44,000 CFM. FBC | | | 106.1.1 | | | | | | 5. M2.01: WHAT IS THE ELEVATION OF CU-T1 AND AMF-1? | | | APPLIANCES LOCATED IN PUBLIC GARAGES, MOTOR | | | FUEL-DISPENSING FACILITIES, REPAIR GARAGES OR OTHER | | | AREAS FREQUENTED BY MOTOR VEHICLES, SHALL BE INSTALLED | | | A MINIMUM OF 8 FEET ABOVE THE FLOOR. WHERE MOTOR | | | VEHICLES EXCEED 6 FEET IN HEIGHT AND ARE CAPABLE OF | | | PASSING UNDER AN APPLIANCE, APPLIANCES SHALL BE | | | INSTALLED A MINIMUM OF 2 FEET HIGHER ABOVE THE FLOOR | | | THAN THE HEIGHT OF THE TALLEST VEHICLE. | | | EXCEPTION: THE REQUIREMENTS OF THIS SECTION SHALL NOT | | | APPLY WHERE THE APPLIANCES ARE PROTECTED FROM MOTOR | | | VEHICLE IMPACT AND INSTALLED IN ACCORDANCE WITH NFPA | | | 88B. | | | | | | 6. M2.01: PROVIDE WALL MOUNTING DETAIL FOR CU-T1 WHICH | | | WORKS IN CONJUNCTION WITH MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS, ESPECIALLY RELATED TO REQUIRED CLEARANCES | | | FOR AIRFLOW, AND IS PROTECTED FROM MECHANICAL DAMAGE | | | PER FBC,M 303.1 AND 303.4. | | | | | | 7. M2.02: FOR CU-T2, CU-T3, CU-G1, CU-G@, CU-SGR1 AND | | | AMF-1 PLEASE SEE COMMENTS 5 AND 6. | | | | | | 8. M2.02: PLEASE SHOW HOW SERVICE ROOM 019 IS TO BE | | | MAINTAINED AT A POSITIVE PRESSURE IN ACORDANCE WITH | | | FBC,M 404.3 AND PROVIDED VENTILATION AS REQUIRED BY | | | FBC,M 403.3. | | | | | | 9. M2.02: FUTURE TENANT COMMERCIAL SPACE #14 FRESH AIR | | | INTAKE LOUVER IS INSIDE THE PARKING GARAGE. THE AIR | | | REQUIRED BY FBC,M 403.3 SHALL NOT BE RECIRCULATED PER | | | 403.2.1. ALSO, INTAKE OPENING LOCATIONS SHALL BE IN | | | COMPLIANCE WITH FBC,M 401.5.1. | | | | | | 10. M2.03: ARE INTAKE LOUVERS FOR THE GENERATOR MINIMUM | | | 10' FROM EXHAUST LOUVERS ON MEZZANINE LEVEL (M2.06)? | | | FBC,M 401.5.1. ALSO, WHAT IS THE HEIGHT OF THE | | | GENERATOR EXHAUST OUTLET? IS IT ON GROUND LEVEL OR | | | MEZZANINE LEVEL? IT IS SHOWN ON BOTH PLANS. PLEASE | | | CLARIFY AND SHOW COMPLIANCE WITH FBC,M 401.5.2 AND | | | 501.2. | | | | | | 11. M2.03: WHERE IS THE CONTINUATION OF THE 8" ROUND | | | EXHAUST DUCT FROM BATHROOMS AND JANITOR'S CLOSET? THERE | | | IS NO CONTINUATION ON M2.06 AS THERE WAS ON PREVIOUS | | | PLAN. FBC 106.1.1 | | | | | | 12. M2.04: FOR AMF-1, PLEASE SEE COMMENT #5. | | | | | | 13. M2.04: PLEASE MARK THE SMOKE EXHAUST RISER SERVING | | | THE MAIN LOBBY AREA. ALSO, IS IT THE INTENT OF THIS | | | DESIGN TO CONVER THE SUPPLY DUCT SYSTEM FOR AHU-12 INTO | | | A SMOKE EXHAUST DUCT WHEN THE AREA GOES INTO SMOKE | | | CONTROL MODE? IF SO, THERE ARE SEVERAL ISSUES WHICH | | | NEED TO BE ADDRESSED: | | | A) SUPPLY DUCT APPEARS TO BE A STANDARD DUCTBOARD AND | | | FLEX SYSTEM. THIS TYPE OF DUCT MAY NOT BE USED FOR ANY | | | TYPE OF EXHAUST PER FBC,M 501.4 AND MUST BE DESIGNED TO | | | MEET THE REQUIREMENTS FOR A SMOKE EXHAUST DUCT PER | | | FBC,M 513.10.2. | | | B) IF SUPPLY REGISTERS AND DIFFUSERS ARE TO BE USED FOR | | | SMOKE EXHAUST, PLEASE PROVIDE SUBMITTAL DATA SHOWING | | | THEIR SUITABILITY FOR USE IN A SMOKE EXHAUST SYSTEM. C) | | | PLAN SHOWS FIRE DAMPERS IN SUPPLY DUCT WHICH APPEARS TO | | | BE INTENDED FOR USE AS SMOKE EXHAUST DUCT. WHERE THE | | | INSTALLATION OF A FIRE DAMPER WILL INTERFERE WITH THE | | | OPERATION OF A REQUIRED SMOKE CONTROL SYSTEM IN | | | ACCORDANCE WITH SECTION 513, APPROVED ALTERNATIVE | | | PROTECTION SHALL BE UTILIZED. FBC,M 607.2.1 | | | D) WHAT IS THE AIR BALANCE DESIGN FOR THE DUCT SYSTEM | | | WHEN IN SMOKE CONTROL MODE? FBC 106.1.2. IS THERE | | | MAKE-UP AIR FOR THE 2000 CFM OF EXHAUST? | | | E) PLEASE ALSO CHECK SMOKE EXHAUST DUCTS ON M2.05 TO | | | VERIFY COMPLIANCE WITH THE ABOVE REQUIREMENTS. | | | | | | 14. M2.05: FOR AMF-1, PLEASE SEE COMMENT #5. | | | | | | 15. M2.05: THERE ARE SOME DUCTS RELATED TO THE SMOKE | | | EXHAUST WHICH ARE MISSING SIZES ON PLANS. PLEASE | | | CLARIFY. FBC 106.1.1 | | | | | | 16. M2.06: THERE IS NO SEPARATION BETWEEN AREAS MARKED | | | AS "COMMERCIAL #15 AND "STORAGE." ARE THERE WALLS | | | MISSING FROM THE PLAN? THIS MAY IMPACT THE NEED FOR | | | FIRE DAMPERS PER FBC,M 607.5. | | | | | | 17. M2.06: WHAT IS THE DESIGNATION, SIZE AND CFM OF | | | RETURN GRILL IN THE 18X10 DUCT IN "STORAGE?" | | | | | | 18. M2.07 REGARDING AMF-1 AND CU-E1, PLEASE SEE COMMENT | | | #5. | | | | | | 19. M2.07: ACORDING TO THE REFLECTIVE CEILING PLAN, THE | | | ELEVATOR LOBBY AND CORRIDOR HAVE THE SAME CEILING | | | HEIGHT. HOW IS IT POSSIBLE TO HAVE SIDEWALL GRILLS (TWO | | | 36X6) FOR SMOKE EXHAUST UNDER THESE CONDITIONS? HOW | | | DOES THE FIRE WRAP INTERACT WITH THE RATED | | | CORRIDOR/ELEVATOR LOBBY WALLS? HOW ARE THE OPENINGS AT | | | THE END OF THE FIRE WRAP PROTECTED AT THE 36X6 GRILLS? | | | THIS WOULD ESSENTIALLY BE UNPROTECTED OPENINGS IN A | | | 2-HOUR SHAFT. THE OVERALL INTENT OF THE DESIGN OF THIS | | | AREA IS UNCLEAR AND MAY BE LACKING COORDINATION WITH | | | ARCHITECTURAL PLANS. | | | | | | 20. M2.08: REGARDING AMF-1 AND CU-19, PLEASE SEE | | | COMMENT #5. REGARDING CU-E2, PLEASE SEE COMMENTS 5 AND | | | 6. | | | | | | 21. M2.08: FOR SMOKE EXHAUST DUCT IN CORRIDOR ACROSS | | | FROM ELECTRICAL ROOM, PLEASE SEE COMMENT #19. | | | | | | 22. M2.08: PLEASE SHOW VENTILATION (OUTDOOR AIR) RATE | | | OF 0.05 CFM PER SQ.FT FOR STORAGE AREA AND SHOW HOW THE | | | AREA WILL BE MAINTAINED AT A POSITIVE PRESSURE PER | | | FBC,M 404.3. | | | | | | 23. M2.09: ARE SHOWN AS BEING REVISED ON PLAN IS | | | CLOUDED AND MARKED AS REVISION 6, BUT REVISIONS LISTED | | | IN TITLE BLOCK AREA ONLY GO TO REVISION 4. PLEASE | | | CLARIFY. FBC 106.1.3. | | | | | | 24. M2.10: PLEASE SEE COMMENTS 5 AND 19. | | | | | | 25: M2.10: ELECTRICAL ROOM IN CORRIDOR SHOWS AN | | | UNDERCUT DOOR FOR AIRFLOW. HOWEVER, THERE IS NO | | | MECHANICAL EQUIPMENT OR MEANS TO CAUSE AIRFLOW INTO THE | | | ELECTRICAL ROOM. ALSO, THE ELCTRICAL ROOM DOOR IS PART | | | OF A FIRE AND SMOKE BARRIER (CORRIDOR) AND THEREFORE | | | SHOULD NOT BE UNDERCUT OR HAVE ANY GAP WHICH IS NOT | | | PART OF A LISTED RATED DOOR ASSEMBLY.. | | | | | | 26. M2.11: PLEASE SEE ALL COMMENTS FOR PAGE M2.08 | | | (20,21,22). ALSO, SEE COMMENT #25 RELATED TO ELECTRICAL | | | AND STORAGE ROOMS. | | | | | | 27. M2.13 AND M2.16: PLEASE SEE COMMENTS 5, 19 AND 25. | | | | | | 28. M2.14 AND M2.17: PLEASE SEE COMMENTS 20,21,22. | | | ALSO, PLEASE SEE COMMENT #25 FOR ELECTRICAL AND STORAGE | | | ROOMS. | | | | | | 29. M2.15: AREA CLOUDED AS REVISED IS MARKED A REVISION | | | 7, HOWEVER THE REVISION SCHEDULE SHOWN IN TITLE BLOCK | | | AREA ONLY GOES TO REVISION 4. PLEASE CLARIFY PER FBC,M | | | 106.1.3. | | | | | | 30. M2.17: THERE IS A "BOILER ROOM" LOUVER CALCULATION | | | BOX ADDED TO PLAN BUT IT IS NOT MARKED AS PART OF THIS | | | REVISION. PLEASE CLARIFY. ALSO, THE BOILER/POOL | | | EQUIPMENT ROOM HAS A NOTE WHICH STATES "DESIGN | | | PENDING." THIS AREA CAN NOT BE FULLY REVIEWED WITH | | | INCOMPLETE INFORMATION. | | | | | | 31. M2.17: HOW ARE DUCT PENETRATIONS AT THE BOTTOM OF | | | THE SHAFT FOR POOL ROOM VENT DUCT AND BOILER FLUE TO BE | | | PROTECTED? FBC 707.11 AND FBC,M 606.5.5.1 | | | | | | 32. M2.17: COMBUSTION AIR DUCT FOR BOILER ROOM SHOULD | | | BE DESIGNED PER FBC,FG 304.6.1 OR 304.6.2. IF TWO | | | OPENINGS ARE USED, THEN BOTH OPENINGS ARE TO | | | COMMUNICATE DIRECTLY WITH THE OUTDOORS. SEE FIG. | | | 304.6.1(3). | | | | | | 33. M2.17: PLEASE PROVIDE INFORMATION ON TYPE OF | | | VENTING TO BE USED FOR THE BOILER. THE HORIZONTAL | | | LENGTH OF THE VENT CONNECTOR IS PROHIBITED BY FBC, FG | | | TABLE 504.2. | | | | | | 34. M2.19: PLEASE SEE COMMENTS 5 AND 19. | | | | | | 35. M2.19: DOES THE RATING OF THE CORRIDOR CONTINUE | | | INTO THE DECK LOBBY AREA? IF SO, ALL PENETRATIONS SHALL | | | BE PROTECTED PER FBC,M 607.5. ALSO, THE CORRIDOR (EXIT | | | ENCLOSURE) VENTILATION SYSTEM SHALL BE INDEPENDENT OF | | | OTHER BUILDING VENTILATION SYSTEMS PER FBC,M 401.4. | | | | | | 36. M2.19: WHERE ARE THE REFRIGERANT LINES AND MEANS OF | | | CONDENSATE DISPOSAL FOR AHU 17? FBC 106.1.1. | | | | | | 37. M2.19: PLEASE SEE COMMENT #19 RELATED TO SMOKE | | | EXHAUST DUCT ACROSS FROM THE ELECTRICAL ROOM. | | | | | | 38. M2.20: PLEASE PROVIDE CONTINUATION OF ROOM ON POOL | | | DECK WITH AHU 18. NONE COULD BE FOUND ON PLANS. FBC | | | 106.1.1. | | | | | | 39. M2.20,M2.23, M2.26, M2.29: PLEASE SEE COMMENT #19 | | | REGARDING SMOKE EXHAUST DUCT ACROSS FROM ELECTRICAL | | | ROOM AND COMMENT #25 REGARDING ELECTRICAL AND STORAGE | | | ROOM DOORS. | | | | | | 40. M2.22: PLEASE SEE COMMENT #19. | | | | | | 41. M2.25, M.28: PLEASE SEE COMMENTS 19 AND 25. | | | | | | 42. M2.32: SEF-2 SHOWS A FIRE DAMPER IN THE DUCT. WHERE | | | THE INSTALLATION OF A FIRE DAMPER WILL INTERFERE WITH | | | THE OPERATION OF A REQUIRED SMOKE CONTROL SYSTEM IN | | | ACCORDANCE WITH SECTION 513, APPROVED ALTERNATIVE | | | PROTECTION SHALL BE UTILIZED. FBC,M 607.2.1 | | | | | | 43. M2.33: PLEASE PROVIDE SIZE AND OTHER RELEVANT DATA | | | FOR INTAKE SIDE DUCT FOR SPF-1 AND SPF-2. FBC 106.1.1 | | | | | | 44. M2.33: RELIEF DAMPER APPEARS TO BE INSIDE THE STAIR | | | ENCLOSURE. SHOULD IT BE AN AN EXTERIOR WALL? | | | | | | 45. M3.01 THROUGH M3.06: MANY CHANGES ON PAGES, NONE | | | ARE MARKED AS REVISIONS. PLEASE CLEARLY MARK ON PLANS | | | THE AREAS WHICH ARE BEING REVISED AND INDICATE A DATE | | | AND REVISION NUMBER. FBC 106.1.1 AND FBC 106.1.3. | | | | | | 46. M4.01: THERE HAVE BEEN SEVERAL REVISIONS TO THIS | | | PAGE SINCE THE PERMITTED SET. PLEASE CLEARLY MARK ALL | | | CHANGES WHICH HAVE TAKEN PLACE SINCE THE PERMITTED SET | | | OF PLANS. FBC 106.1.3. | | | | | | 47. M4.02: THE DESIGNATED CFM OF EXHAUST ON EACH FLOOR | | | DO NOT MATCH THE CFM AS SHOWN ON FLOOR PLANS. PLEASE | | | COORDINATE DRAWINGS. | | | | | | 48. M5.01: THIS PAGE GOES FROM REVISION 1 TO REVISION | | | 3. PLEASE SHOW WHAT CHANGES HAVE BEEN MADE RELATED TO | | | REVISION 2. FBC 106.1.3. | | | | | | 49. M5.02: THIS PAGE CONTAINS 2 PAGES OF SCHEDULES AND | | | HAVE BEEN REDUCED IN SIZE AND QUALITY TO A POINT WHERE | | | MUCH OF THE INFORMATION IS NOT LEGIBLE. PLEASE CORRECT. | | | FBC 106.1.3 | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2007-02-22 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-02-22 |
Time |
18:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-02-22 |
Time |
18:22 |
Sent To |
|
|
| Notes |
| 2007-02-22 18:27:58 | PASS PROVISOPLEASE PROVIDE A COPIE OF MANUFATURERS | | | INSTALLATION INSTRUCTIONS FOR CONDENSORS IN THE | | | GARAGE. | | | PLEASE REFER TO SECTION 303.4 FBC(M) 2004 PROTECTION | | | FROM DAMAGE. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
F |
Date |
2006-12-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2006-12-19 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2006-12-19 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2006-12-19 13:33:10 | PLANS DENIED | | | PLANS SUBMITED FOR MECHANICAL ARE NO GOOD.I CALLED | | | STEVEN FELLER HE IS GO TO SUBMIT NEW REVISIONS. | | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2006-08-31 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-31 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-25 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2006-09-01 00:00:00 | PROVISO: | | | 1.PLEASE NOTE, CO SENSORS LOCATED IN | | | THE GARAGE SHALL BE CONNECTED TO | | | EMERGENCY POWER. | | | | | | 2.PLEASE VERIFY WITH THE MANUFACTURER, | | | THE DISTANCE OF THE LINE SETS TO THE | | | CONDENSING UNITS LOCATED ON THE ROOF. | | | PLEASE SUBMIT VERIFICATION. | | | | | | 3.SPECIFIC DRYERS ARE TO BE INSTALLED | | | AT FINAL INSPECTION. PLEASE NOTE THE | | | FOLLOWING UNITS EXCEED THE | | | MANUFACTURER'S RECOMMENDED EXHAUST | | | LENGTH; A4, A4A, A4B, & A7.PLEASE | | | PROVIDE REVISION ADDRESSING THIS ISSUE | | | WITHIN 30 DAYS OF THE PERMIT BEING | | | ISSUED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2006-08-01 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-08-01 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-08-01 |
Time |
07:40 |
Sent To |
|
|
| Notes |
| 2006-08-01 00:00:00 | DENIED: | | | RESPONSE LETTER DATED 6/9/06TO COMMENTS | | | DATED 5/9/06 & 12/27/05: | | | | | | COMMENT 1:OK | | | | | | COMMENT 2:RESPONSE INDICATES O.A. | | | CALCS PROVIDED ON PLAN SHEET M5.02. | | | O.A. CALCULATIONS ARE ALSO REQUIRED FOR | | | THE RESIDENTIAL UNITS IN ACCORDANCE WITH | | | 2004 FMC 403.3.PLEASE NOTE, OUTSIDE | | | AIR CALC SCHEDULE INDICATED ON PLAN | | | SHEET M5.02 NOTE 2 REFERENCES ASHRAE | | | 62-89.THIS SHOULD READ ASHRAE 62-01. | | | | | | COMMENT 3:OK | | | | | | COMMENT 4:RESPONSE INDICATES SMOKE | | | CONTROL WAS REMOVED FROM THE RETAIL | | | AREAS. PLEASE ANNOTATE ON THE PLANS | | | SEQUENCE OF OPERATION IN THE EVENT OF A | | | FIRE.SHOW COMPLIANCE WITH 2004 FBC | | | 909. | | | | | | COMMENT 5:RESPONSE STATES THE AHU'S | | | HAVE BEEN RELOCATED TO THE MEZZANINE | | | LEVEL.COMMENT ALSO REFERS TO THE FLOOR | | | DRAIN LOCATED IN THE RETURN AIR PLENUM | | | WHICH IS NOT IN ACCORDANCE WITH 2004 FPC | | | 901.2 & ASHRAE 62-01, 8.4.1.11. | | | | | | COMMENT 6:OK | | | COMMENT 7:OK | | | COMMENT 8:OK | | | COMMENT 9:OK | | | COMMENT 10: OK | | | COMMENT 11: OK | | | COMMENT 12: OK | | | COMMENT 13: OK | | | COMMENT 14: OK | | | | | | COMMENT 15: GENERATOR INFORMATION IS OK | | | HOWEVER THE EXHAUST IS WITHIN 10 FT OF | | | THE INTAKE LOUVERAND THE SWITCHGEAR | | | DOOR.PLEASE CLARIFY. | | | | | | COMMENT 16: OK | | | *****************NEW COMMENT************ | | | 17. PLAN SHEET M6.02 THE DETAIL SHOWING | | | THE VERTICAL AHU SHOWS CPVC CONDENSATE | | | TERMINATING 2" ABOVE A FLOOR DRAIN IN | | | THE MECHANICAL CLOSET.THIS MECHANICAL | | | CLOSET IS A RETURN AIR PLENUM.PER 2004 | | | FMC 602.2.1, COMBUSTIBLES ARE NOT | | | ALLOWED IN THE RETURN AIR PLENUM. | | | PROVIDE MANUFACTURER SUBMITTAL ON THE | | | CPVC INDICATING IT MEETS THE DEFINITION | | | OF NONCOMBUSTIBLE IN ACCORDANCE WITH THE | | | ABOVE REFERENCED CODE.PLEASE ALSO SEE | | | COMMENT #5 WITH REGARDS TO THE FLOOR | | | DRAIN IN THE RETURN AIR PLENUM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2006-05-09 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2006-05-09 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2006-05-09 |
Time |
07:20 |
Sent To |
|
|
| Notes |
| 2006-05-09 00:00:00 | DENIED: | | | PLEASE NOTE, A RESPONSE LETTER TO | | | COMMENTS GENERATED 12/27/05 WAS NOT | | | SUBMITTED.PLEASE PROVIDE RESPONSE | | | LETTER WITH THE NEXT RESUBMITTAL TO HELP | | | EXPEDITE PLANS. | | | | | | THE FOLLOWING COMMENTS FROM REVIEW DATED | | | 12/27/05 WERE NOT ADDRESSED: | | | | | | COMMENT #1:MECHANICAL PLANS ARE | | | SIGNED, SEALED, AND DATED BY THE | | | ENGINEER.THE ARCHITECT'S SEAL IS NOT | | | LEGIBLE. | | | | | | COMMENT #2:OK | | | | | | COMMENT #3:OK | | | | | | COMMENT #4:SMOKE EXHAUST/CONTROL FOR | | | THE RETAIL SPACE.PLAN SHEET M2.01, | | | 2.02, & 2.03 ALL INDICATE FIRE SMOKE | | | DAMPERS AND SUPPLY & RETURN DUCTS.PLAN | | | SHEET M0.00 & M2.03 STATE "SMOKE EXHAUST | | | THROUGH NATURAL VENTILATION" FROM | | | WINDOWS AND PANELS OPERABLE FROM THE | | | FIRE FLOOR OR PANELS OF APPROVED, FIXED, | | | FULLY TEMPERED GLASS LOCATED AROUND THE | | | PERIMETER.THIS IS NOT DEMONSTRATED. | | | PLEASE CLARIFY.PLEASE SPECIFY WHAT | | | "OAFR" & SXFR" STAND FOR.PLEASE NOTE, | | | PLAN SHEET M2.01 "OAFR" DEPICTS SUPPLY | | | GRILLES TO THE RETAIL SPACE & SXFR | | | DEPICTS RETURN WITH BOTH RUNS TO RETAIL | | | SPACE 3 THROUGH 7 TERMINATING INTO THE | | | ENCLOSED PARKING GARAGE.PER 2004 FMC | | | 401.5.1, INTAKE OPENINGS SHALL BE | | | LOCATED A MINIMUM OF 10 FT FROM ANY | | | HAZARDOUS OR NOXIOUS CONTAMINANT SUCH AS | | | PARKING LOTS & LOADING DOCKS.PLEASE | | | ALSO REFERENCE 2004 FMC 510.5.5, MAKEUP | | | AIR SHALL BE LCOATED SO AS TO AVOID | | | RECIRCULATION OF CONTAMINATED AIR. | | | | | | COMMENT #5:OK.PLEASE NOTE, | | | MECHANICAL ROOMS USED AS RETURN AIR | | | PLENUM, NO FLOOR DRAINS PERMITED IN | | | MECHANICAL ROOMS PER 2004 FPC 901.2 & | | | ASHRAE 62-01 8.4.1.11. | | | | | | COMMENT #6:OK | | | | | | COMMENT #7:WAS NOT ADDRESSED - PLAN | | | SHEET M2.01 (ROOM #006 &011) FLEX DUCTS | | | PENETRATING WALLS/PARTITIONS WITH FIRE | | | RATING.FIRE DAMPERS ARE NOT INDICATED | | | ON THE PLAN SHOW COMPLIANCE WITH 2004 | | | FMC 607.5.3 #2 OR PROVIDE FIRE DAMPERS. | | | LOCATION OF ALL FIRE DAMPERS ARE TO | | | INDICATED ON PLANS 2004 FMC 607.8. | | | | | | COMMENT #8:INDICATE LOCATION OF ALL | | | FIRE DAMPERS & ACCESS DOORS PER 2004 FMC | | | 607.8. | | | | | | COMMENT #9:ADDRESSED ON PLAN SHEET | | | M6.02. | | | | | | COMMENT #10: OK | | | | | | COMMENT #11: SUBMITTALS ON EQUIPMENT WAS | | | NOT SUBMITTED. | | | | | | COMMENT #12: ENERGY CALCULATIONS WERE | | | NOT SUBMITTED. | | | | | | COMMENT #13: SUBMITTAL ON THE GENERATOR | | | WAS NOT SUBMITTED. | | | **************************************** | | | NEW COMMENTS: | | | 14. PLAN SHEET M2.01, AIR MAKE-UP TO THE | | | SMOKE CONTROL SYSTEM FOR THE RETAIL | | | AREAS IS COMING FROM THE GARAGE.PER | | | FMC 401.5.1 & 510.5.5, FRESH AIR INTAKES | | | SHALL BE LOCATED A MINIMUM OF 10 FT FROM | | | PARKING LOTS OR LOADING DOCKS AND AVOID | | | THE RECIRCULATION OF OF CONTAMINTED AIR. | | | PLEASE NOTE THE OAFR LOCATED IN RETAIL | | | SPACE #7, INDICATES EXHAUST NOT INTAKE. | | | | | | 15. PLAN SHEET M2.03, PLEASE PROVIDE THE | | | ELEVATION FOR THE MUFFLER & RADIATOR | | | EXHAUST TERMINTION (BOTTOM OF PIPE & | | | BOTTOM OF LOUVER).PLEASE NOTE, PER | | | 2004 NFPA 37 6.3.5.4.2, EXHAUST | | | VENTILATION SHALL BE TO A SAFE LOCATION | | | OUTSIDE THE BUILDING, WITHOUT | | | RECIRCULATION OF THE EXHAUST AIR. | | | PLEASE NOTE, EXHAUST IS WITHIN 10 FT OF | | | THE INTAKE LOUVER AND THE SWITCHGEAR | | | ROOM DOOR. | | | | | | 16. PLAN SHEET M2.04, PLEASE CLARIFY THE | | | RATING OF THE MECHANICAL CLOSET IN WHICH | | | AHU-12 IS LOCATED. PLAN SHEET A1.3 DOES | | | NOT SPECIFY RATING AT THE MEZZANINE | | | LEVEL. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-12-27 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2005-12-27 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2005-12-27 00:00:00 | DENIED:CITY PALMS/10 STORY | | | 2004 FLORIDA BUILDING CODE | | | | | | 1.PLANS ARE TO SIGNED, SEALED AND | | | DATED BY THE ENGINEER OF RECORD IN | | | ACCORDANCE WITH FS 471.025. | | | | | | 2.PLEASE PROVIDE OUTSIDE AIR | | | CALCULATIONS PER 2004 FMC TABLE 403.3. | | | | | | 3.PLAN SHEET A1.0 DOES NOT INDICATE | | | TENANT SEPARATION BETWEEN THE RETAIL | | | SPACES. | | | | | | 4.PLAN SHEET M2.01 INDICATES FBC 412.5 | | | SMOKE EXHAUST THROUGH NATURAL | | | VENTILATION FOR RETAIL SPACE.PLEASE | | | NOTE, SMOKE CONTROL & EXHAUST UNDER THE | | | 2004 FLORIDA BUILDING CODE IS NOW | | | ADDRESSED IN 513 OF THE FLORIDA | | | MECHANICAL CODE.PLEASE INDICATE METHOD | | | AND CALCULATIONS FOR SMOKE CONTROL. | | | | | | 5.PLAN SHEET M2.01 AHU-12, 13 & 14 ARE | | | LOCATED IN A STORAGE ROOM, PLEASE | | | CLARIFY. | | | | | | 6.AHU-13 IS NOT INDICATED ON THE | | | EQUIPMENT SCHEDULE (M5.01). | | | | | | 7.PLAN SHEET M2.01 (ROOM #006 & 011) | | | FLEX DUCTS PENETRATING WALLS/PARTITIONS | | | WITH FIRE RATING & FIRE DAMPERS ARE NOT | | | INDICATED.DUCT SHALL COMPLY WITH 2004 | | | FMC 607.5.3 #2. | | | | | | 8.PLEASE INDICATE ALL FIRE & FIRE | | | SMOKE DAMPERS ON PLAN IN ACCORDANCE WTIH | | | 2004 FMC 607.5.3. | | | | | | 9.PLEASE CLARIFY DETAIL OF THE | | | REFRIGERANT LINE SETS ON PLAN SHEET | | | M5.01.WILL LINE SETS BE IN A SHAFT?. | | | DETAIL INDICATES GOOSE NECK THAT APPEARS | | | TO END AT THE SLAB, BUT THE NOTE STATES | | | "SLEEVE TO PROVIDE VENTILATION PER | | | ASHRAE 15".PLEASE INDICATE WHERE | | | SHAFTS WILL BE VENTILATED. | | | | | | 10. PROVIDE CALCULATION FOR THE | | | REFRIGERANT PER TABLE 1103.1 OF THE 2004 | | | FMC. | | | | | | 11. PROVIDE MANUFACTURER'S | | | SPECIFICATIONS FOR EQUIPMENT. | | | | | | 12. PLEASE PROVIDE ENERGY CALCULATIONS | | | IN ACCORDANCE WITH 2004 FBC CHAPTER 13. | | | | | | 13. PLEASE PROVIDE SUBMITTAL FOR THE | | | GENERATOR. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
38 |
Status |
P |
Date |
2008-12-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-23 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-23 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2008-12-23 17:52:11 | REVISION APPROVED -- SHTS P2.31, P3.10 & P3.11 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
37 |
Status |
F |
Date |
2008-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-17 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-16 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2008-12-17 17:30:56 | REVSIONS DENIED | | | REFERENCE: | | | FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.31 REVISION 2 ADDENDUM #3 DATED 4-17-06 AS | | | SHOWN ON THE FILE SET OF PLANS FOR PUBLIC RECORD HAS | | | BEEN CHANGED TO REVISION 4. ALL REVISIONS SHALL BE | | | INDICATED ON THE REVISION INDEX FOR THE LIFE OF THE | | | PROJECT. NEW REVISIONS SHALL BE INDICATED WITH CLOUDS | | | AND A NEW REVISION NUMBER. SECTION 106.1.3. | | | | | | 2. SHT P3.10 THE DRAIN LINE FROM THE THERMAL EXPANSION | | | VALVE IS SHOWN CONNECTING DIRECTLY TO THE PAN DRAIN | | | LINE. PER SECTION 608.1 POTABLE WATER SHALL BE | | | DESIGNED, INSTALLED, INSTALLED AND MAINTAINED TO | | | PREVENT CONTAMINATION FROM NONPOTABLE LIQUIDS, SOLIDS | | | OR GASES BEING INTRODUCED INTO THE POTABLE WATER SUPPLY | | | THROUGH CROSS-CONNECTIONS. AN AIR GAP OR AIR GAP | | | FITTING IS REQUIRED. TABLE 608.1. -- KEY NOTES #5 SHOWS | | | NOT CHANGE & KEY NOTE #7 HAS BEEN ADDED WITHOUT A CLOUD | | | TO INDICATE A REVISION NOR A REVISION NUMBER. PLEASE | | | CLOUD AND NUMBER ALL REVISIONS. SECTION 106.1.3. | | | | | | 3. SHT P3.11 THE DRAIN LINE FROM THE THERMAL EXPANSION | | | VALVE IS SHOWN CONNECTING DIRECTLY TO THE PAN DRAIN | | | LINE. PER SECTION 608.1 POTABLE WATER SHALL BE | | | DESIGNED, INSTALLED, INSTALLED AND MAINTAINED TO | | | PREVENT CONTAMINATION FROM NONPOTABLE LIQUIDS, SOLIDS | | | OR GASES BEING INTRODUCED INTO THE POTABLE WATER SUPPLY | | | THROUGH CROSS-CONNECTIONS. AN AIR GAP OR AIR GAP | | | FITTING IS REQUIRED. TABLE 608.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
36 |
Status |
P |
Date |
2008-12-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-16 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-16 |
Time |
18:58 |
Sent To |
|
|
| Notes |
| 2008-12-16 18:59:37 | REVISION OK -- SHTS P2.05, P2.06, P2.17, P2.18, P2.21, | | | P2.22, P2.25, P2.28. P2.33, P3.01, P3.14 & P4.01 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
35 |
Status |
F |
Date |
2008-12-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-12-01 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-12-01 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2008-12-01 10:09:27 | REVISION DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.05 REVISION NUMBER 12, KEY NOTES 12 & 13 NOT | | | FOUND ON THE FLOOR PLAN. PLEASE CORRELATE. SECTION | | | 106.1.1 | | | | | | 2. SHT P2.05 CHANGES TO THE CONDENSATE ARE NOT CLOUDED | | | OR INDICATED WITH A REVISION NUMBER. PLEASE CLOUD AND | | | NUMBER ALL REVISIONS TO THE PREVIOUSLY REVIEWED AND | | | STAMPED SHEET. SECTION 106.1.3. (ALSO SEE KEY NOTES 12, | | | 13 & 14 ADDED WITHOUT CLOUD/NUMBER). | | | | | | 3. SHT P2.05 REVISION NUMBER 13 INDICATED ON THE | | | REVISION INDEX IS NOT FOUND ON THE FLOOR PLAN AND | | | REVISION NUMBER 6 PREVIOUSLY INDICATED IN THE REVISION | | | INDEX ON SHEET PREVIOUSLY REVIEWED AND STAMPED HAS BEEN | | | DELETED. THE REVISION INDEX HISTORY SHALL BE MAINTAINED | | | FROM REVISION TO REVISION. PLEASE CORRELATE. SECTION | | | 106.1.1. | | | | | | 4. SHT P2.06 REVISIONS 7 & 9 INDICATED ON THE REVISION | | | INDEX WERE NOT FOUND ON THE FLOOR PLAN. PLEASE | | | CORRELATE. ALSO CLOUD AND NUMBER ALL KEY NOTE CHANGES | | | OR REVISIONS ON THE FLOOR PLAN. SECTION 106.1.3. | | | | | | 5. SHT P2.17 REVISION 14 INDICATED ON THE REVISION | | | INDEX WAS NOT FOUND ON THE FLOOR PLAN. PLEASE | | | CORRELATE. SECTION 106.1.3. | | | | | | 6. SHT P2.17 NEW KEY NOTES 18, 19 & 20 WERE NOT CLOUDED | | | OR NUMBERED AND KEY NOTE 18 WAS NOT FOUND ON THE FLOOR | | | PLAN. PLEASE CORRELATE AND CLOUD ALL CHANGES SECTION | | | 106.1.3. | | | | | | 7. SHT P2.17 KEY NOTE NUMBER 16 TO THE RIGHT OF COL. | | | LINE "K" DESIGNATION & LEFT OF COL. LINE 11-1 SHOWS NO | | | PIPING. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 8. SHT P2.18 REVISION NUMBER 6 INDICATED ON THE ISSUED | | | SET OF PLANS HAS BEEN BEEN DELETED. NO NEW REVISION | | | NUMBER HAS BEEN ADDED. THE COMPLETE HISTORY OF | | | REVISIONS SHALL BE MAINTAINED FROM REVISION TO | | | REVISION. SECTION 106.1.3. | | | | | | 9. SHT P2.21 REVISION NUMBER 6 INDICATED ON THE ISSUED | | | SET OF PLANS HAS BEEN BEEN DELETED. NO NEW REVISION | | | NUMBER HAS BEEN ADDED. THE COMPLETE HISTORY OF | | | REVISIONS SHALL BE MAINTAINED FROM REVISION TO | | | REVISION. SECTION 106.1.3. | | | | | | 10. SHT P2.22 SUBMIT A U/L RATING & DETAIL OF FIRE | | | RATING OF THE WALL & SUBMIT A DETAIL SHOWING HOW THE | | | STRUCTURAL INTEGRITY OF THE COLUMN IS MAINTAINED WHERE | | | THE LAV ARE IS ROUTED THRU THE COLUMN. SECTION 106.1.2. | | | | | | 11. SHT P2.25 SUBMIT A U/L RATING & DETAIL OF FIRE | | | RATING OF THE WALL & SUBMIT A DETAIL SHOWING HOW THE | | | STRUCTURAL INTEGRITY OF THE COLUMN IS MAINTAINED WHERE | | | THE LAV ARE IS ROUTED THRU THE COLUMN. SECTION 106.1.2. | | | | | | 12. SHT P2.28 SUBMIT A U/L RATING & DETAIL OF FIRE | | | RATING OF THE WALL & SUBMIT A DETAIL SHOWING HOW THE | | | STRUCTURAL INTEGRITY OF THE COLUMN IS MAINTAINED WHERE | | | THE LAV ARE IS ROUTED THRU THE COLUMN. SECTION 106.1.2. | | | | | | 13. SHT P2.28 SHOW REVISION 11 IN TRIANGLE FOR REVISION | | | NUMBER 11 ON THE FLOOR PLAN. SECTION 106.1.3. (TRIANGLE | | | BLANK). | | | | | | 14. SHT P2.31 REVISION INDEX REVISION NUMBERS 1 & 2 | | | WERE DELETED, REVISION NUMBER 2 WAS CHANGED TO REVISION | | | NUMBER 4, ADDENDUM NUMBER 5 WAS ADDED TO REVISION | | | NUMBER 5, KEY NOTES NUMBER 3 CHANGED WITH REVISION | | | NUMBER 6 WAS NOT FOUND ON THE FLOOR PLAN, REVISON | | | NUMBER 7 WAS FOUND ON THE FLOOR PLAN BUT NOT IN THE | | | REVISION INDEX, AND KEY NOTES 4 & 5 ADDED BUT NO CLOUD | | | OR REVISION NUMBER INDICATING THE REVISION. PLEASE | | | CORRELATE, MAINTAIN THE REVISION HISTORY, SHOW ALL | | | REVISIONS WITH CLOUDS & REVISION NUMBERS ETC. SECTIONS | | | 106.1.1, 106.1.2 & 106.1.3. | | | | | | 15. SHT P2.33 REVISION INDEX ON THE SHEET STAMPED AND | | | REVIEWED BY THE CITY WPB ON SEPT. 08, 2006 SHOWS | | | REVISIONS 2, 3 & 4. THE NEW REVISIED SHEET SUBMITTED | | | HAS REVISIONS 3, 4, 5, 6 & 11. REVISION 2 HAS BEEN | | | DELETED, REVISION 3 HAS A DIFFERENT DATE, REVISION 4 | | | HAS A DIFFERENT DATE, & REVISION 5 WAS NOT FOUND ON THE | | | FLOOR PLAN. THE REVISION HISTORY SHALL BE MAINTAINED | | | THRU THE LIFE THE THE PLANS. CORRELATE NEW REVISION | | | NUMBERS WITH THE FLOOR PLAN. SECTION 106.1.3. | | | | | | 16. SHT P3.01 RISERS FOR 2, 3, 10, 11, 12 & 13 AND 36, | | | 37, 42 & 44 SHOW A 3" DRAINAGE LINE FROM THE COLLECTOR | | | TANK OVERFLOWS. THE OVERFLOW SHALL DRAIN TO THE STORM | | | SYSTEM. MUNICIPAL CODE ARTICLE III SECTION | | | 90-125(B)(5). | | | | | | 17. SHT P3.10 SHOWS REVISION NUMBER 4 ON THE FLOOR PLAN | | | BUT IS NOT INDICATED ON THE REVISION INDEX. THE | | | REVISIONS IN KEY NOTES ARE NOT INDICATED WITH CLOUDS OR | | | REVISION NUMBER. SECTION 106.1.3. | | | | | | 18. SHT P3.11 KEY NOTES NUMBER 4 DOES NOT REFLECT | | | CHANGES ON THE WATER UNIT DETAILS. PLEASE | | | CLARIFY/CORRELATE. SECTIONS 106.1.1 & 106.1.2. | | | | | | 19. SHT P3.14 REVISION NUMBER 6 HAS BEEN DELETED FROM | | | THE REVISION HISTORY. PLEASE MAINTAIN THE REVISION | | | HISTORY THRU THE LIFE TO THE PLANS. SECTION 106.1.3. | | | | | | 20. SHT P4.01 REVISION NUMBER 2 HAS BEEN DELETED FROM | | | THE REVISION HISTORY. PLEASE MAINTAIN THE REVISION | | | HISTORY THRU THE LIFE TO THE PLANS. THE FUEL PIPING | | | DETAIL FOR FOR THE MECHANICAL PLAN REVIEWER. PLEASE | | | DELETE FROM PLUMBING AND SUBMIT REVISION UNDER THE | | | MECHANICAL PLANS. SECTION 106.1.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
34 |
Status |
P |
Date |
2008-11-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-11-26 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-11-26 |
Time |
16:15 |
Sent To |
|
|
| Notes |
| 2008-11-26 16:18:11 | REVISIONS OK -- SHT P2.01, P2.02, P2.08, P2.11, P2.13, | | | P2.14, P2.16, P2.34, P3.04, P3.06, P3.07 & P3.13. --- | | | RESTAMP OK -- SHT P2.29. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
33 |
Status |
F |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-23 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-23 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2008-10-23 14:18:06 | RESTAMP DENIED | | | REFERENCE: FBC-2004 CHAPTER 1 | | | | | | THE FOLLOWING SHEETS HAVE BEEN DENIED FOR RESTAMP AS | | | THERE HAVE BEEN REVISIONS ADDED TO OR DELETED FROM | | | PREVIOUSLY REVIEWED REVISIONS. | | | | | | SHTS P2.01 REV. 20, P2.02 REV. 17, P2.05 REV'S 12 - 13 | | | - 14, P2.06 REV'S 7 - 8 - 9, P2.08 REV 14, P2.11 REV | | | 14, P2.13 REV 14, P2.14 REV 14, P2.16 REV 17, P2.18 REV | | | 6 DELETED, P2.21 REV 6 DELETED, REV 2.22 REV 13, P2.25 | | | REV 13, P2.28 REV 11, P2.29 REV "X" ON FLOOR PLAN | | | ADDED, P2.31 REV'S 1 & 2 DELETED & REV'S 4 - 6 - 11 | | | ADDED, P2.33 REV 2 DELETED & REV'S 5 - 6 - 11 ADDED, | | | P2.34 REV 4, P2.35 REV 4, P3.01 REV'S 8 - 9 - 10, P3.03 | | | REV'S 11- 12, P3.04 REV 11, P3.06 REV 7, P3.07 REV 7, | | | P3.10 REV 4, P3.11 REV 4 INFORMATION DELETED AND | | | INFORMATION NOT LEGIBLE, P3.14 REV 6 DELETED & REV 11 | | | ADDED, P3.15 REV 17 & P4.01 REV 2 DELETED & REV'S 3 & 4 | | | ADDED. | | | | | | SUBMIT THE ABOVE SHEETS FOR REVISION, MINIMUM 2 SETS OF | | | PLANS REQUIRED FOR REVISIONS. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
32 |
Status |
P |
Date |
2008-10-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-10-23 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-10-23 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2008-10-23 14:05:03 | RESTAMP APPROVED FOR THE FOLLOWING SHEETS. -- P2.03, | | | P2.04, P2.07, P2.09, P2.10, P2.12, P2.15, P2.19, P2.20, | | | P2.23, P2.24, P2.26, P2.27, P2.30, P2.32. P2.36, P3.05, | | | P3.08, P3.09, P3.12, P3.13 & P4.02 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
31 |
Status |
P |
Date |
2008-09-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-09-02 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-09-02 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2008-09-02 11:09:55 | SUBMITTAL APPROVED. -- PIPE GUARDS FOR THE GARAGE. -- | | | CUT OUT FOR CLEANOUT ACCESS AS REQUIRED FOR FIELD | | | CONDITIONS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
30 |
Status |
F |
Date |
2008-08-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-08-08 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-08-08 |
Time |
14:19 |
Sent To |
|
|
| Notes |
| 2008-08-08 14:24:20 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | | | | 1. SUBMITTAL FOR PIPE GUARDS NOT APPROVED. PLEASE | | | INDICATE HOW ACCESS TO CLEANOUTS REQUIRED BY SECTIONS | | | 708.3.4 & 1101.8 WILL BE ADDRESSED. SECTION 708.9. | | | SUBMIT AN ELEVATION VIEW OF THE GUARD SHOWING HOW | | | ACCESS WILL BE ADDRESSED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
29 |
Status |
N |
Date |
2008-04-21 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-21 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-21 |
Time |
14:33 |
Sent To |
B |
|
| Notes |
| 2008-04-21 14:36:04 | REVISION SHEET L1 THRU L4 AND SHEET I1 AND I2: NO | | | REVISION NUMBER INDICATED AND NO CHANGES FROM ORIGINAL | | | SHEETS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
28 |
Status |
P |
Date |
2008-03-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-03-29 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-03-29 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2008-03-29 15:17:34 | REVISIONS APPROVED--SHT P2.01 REVISION 19 OK - | | | REVISIONS 17 & 18 NOT FOUND OR APPROVED.--SHT P3.12 | | | REVISIONS 16 & 18 OK -REVISIONS 14 & 17 NOT FOUND OR | | | APPROVED. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
27 |
Status |
F |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-26 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-25 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2008-02-26 10:17:01 | DENIED | | | REFERENCE: CITY WPB MUNICIPAL CODE | | | FBC-2001 CHAPTER 1 | | | | | | 1. SHT P2.01 THE LINE DRAINING INTO CATCH BASIN #4 FROM | | | THE FAN ROOM DOES NOT INDICATE WHAT WILL BE DRAINING | | | THROUGH IT. IS THIS STORM WATER? PLEASE CLARIFY. ONLY | | | STORM WATER SHALL DRAIN INTO THE STORM SYSTEM PER | | | ARTICLE III SECTION 90-203(A).--THERE IS NO | | | REVISION NUMBER FOR THIS REVISION CORRELATING WITH THE | | | REVISION NUMBERS OF THIS SUBMITTAL. (17 & 18). | | | | | | 2. SHT P3.12INDICATE THE SQUARE FOOTAGE ON RISER PAD | | | 2 FOR THE NEW DECK DRAINS AND TRENCH DRAINS ON THE | | | RISER DIAGRAM. TABLE 1106.3.--SURGE TANK ADDED TO | | | RISER DP 4 IS INDICATED WITH A REVISION NUMBER 15. | | | NUMBER 15 IS NOT INDICATED ON THE REVISION INDEX, AS | | | ONLY REVISIONS 14, 16 & 17 WERE SUBMITTED FOR REVIEW | | | THIS SUBMITTAL. PLEASE CLARIFY. SECTION 104.2.1.3.-- | | | THE LINE DRAINING INTO CATCH BASIN #4 FROM THE FAN ROOM | | | DOES NOT INDICATE WHAT WILL BE DRAINING THROUGH IT. IS | | | THIS STORM WATER? PLEASE CLARIFY. ONLY STORM WATER | | | SHALL DRAIN INTO THE STORM SYSTEM PER ARTICLE III | | | SECTION 90-203(A). | | | | | | 3. AS INDICATED NUMEROUS TIMES, PLEASE TURN OFF ALL | | | CLOUDS & REVISION NUMBERS FOR REVISIONS THAT HAVE BEEN | | | PREVIOUSLY APPROVED. THIS ADDS MUCH MORE TIME TO EACH | | | REVISION REVIEW AS THE WHOLE SHEET HAS TO BE REVIEWED | | | BECAUSE OF ALL THE CLOUDING. AS THE REVISIONS COME IN | | | EACH REVISION TAKES LONGER TO PROCESS AND THUS SLOWS | | | THE PLAN REVIEW PROCESS MAKING DELAYS IN PERMITTING OF | | | JOBS. PLEASE TURN OFF ALL REVISION CLOUDS AND REVISIONS | | | PREVIOUSLY APPROVED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, IDENTIFYING | | | THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
26 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-26 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-25 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2008-02-26 10:03:37 | REVISIONS OK--SHTS P2.03, P2.19, P2.20, P3.02 & | | | P4.02 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
25 |
Status |
F |
Date |
2007-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-17 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-17 |
Time |
12:44 |
Sent To |
|
|
| Notes |
| 2007-12-17 12:56:49 | REVISIONS DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.03 REVISIONS 7, 8 & 13 WERE NOT FOUND. THE | | | PREVIOUS APPROVED SHEET P2.03 WAS DATED 10-06-2006 AND | | | HAD REVISIONS 3, 4 & 5. PLEASE CLOUD ALL REVISIONS NOT | | | PREVIOUSLY APPROVED AND INDICATE ALL REVISIONS WITH A | | | NUMBERED TRIANGLE. SECTION 106.1.3. | | | | | | 2. SHT P2.19 REVISIONS11 & 13 WERE NOT FOUND. THE | | | PREVIOUS APPROVED SHEET P2.19 WAS DATED 10-06-2006 AND | | | HAD REVISIONS 3, 4, 5 & 6. PLEASE CLOUD ALL REVISIONS | | | NOT PREVIOUSLY APPROVED AND INDICATE ALL REVISIONS WITH | | | A NUMBERED TRIANGLE. SECTION 106.1.3. | | | | | | 3. SHT P2.20 REVISIONS 7, 8 & 13 WERE NOT FOUND. THE | | | PREVIOUS APPROVED SHEET P2.20 WAS DATED 11-20-2007 AND | | | HAD REVISIONS 3, 4, 5 & 6. PLEASE CLOUD ALL REVISIONS | | | NOT PREVIOUSLY APPROVED AND INDICATE ALL REVISIONS WITH | | | A NUMBERED TRIANGLE. SECTION 106.1.3. | | | | | | 4. SHT P3.02 REVISIONS8 & 13 WERE NOT FOUND. THE | | | PREVIOUS APPROVED SHEET P3.02 WAS DATED 11-20-2007 AND | | | HAD REVISIONS 3, 4, 5, 6 & 7. PLEASE CLOUD ALL | | | REVISIONS NOT PREVIOUSLY APPROVED AND INDICATE ALL | | | REVISIONS WITH A NUMBERED TRIANGLE. SECTION 106.1.3. | | | | | | 5. SHT P3.12 REVISION 14 WAS NOT FOUND. THE PREVIOUS | | | APPROVED SHEET P3.12 WAS DATED 11-20-2007 AND HAD | | | REVISIONS 3, 4 & 5. PLEASE CLOUD ALL REVISIONS NOT | | | PREVIOUSLY APPROVED AND INDICATE ALL REVISIONS WITH A | | | NUMBERED TRIANGLE. SECTION 106.1.3. | | | | | | 6. SHT P4.02 REVISION IS INDICATED AS AN ADDITION OF | | | THE GENERATOR WITH DIESEL INFORMATION ONLY. THE DIESEL | | | PERMIT IS A MECHANICAL PERMIT AND AS SUCH ALL REVISIONS | | | FOR DIESEL SHALL BE SUBMITTED ON THE MECHANICAL SHEETS, | | | NOT THE PLUMBING SHEETS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
24 |
Status |
P |
Date |
2007-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-17 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-17 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2007-12-17 12:44:01 | REVISIONS APPROVED. SHEETS P2.01, P2.02, P2.16 & P3.15 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
23 |
Status |
P |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-05 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-05 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2007-12-05 18:58:01 | REVISIONS OK FOR SHTS A1.31, A1.32 & A1.33 FOR THE | | | SCUPPERS AND SCUPPER RELATED REVISIONS ONLY. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
22 |
Status |
P |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-05 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-05 |
Time |
18:12 |
Sent To |
|
|
| Notes |
| 2007-12-05 18:13:13 | REVISION OK - SHTS P3.12 & P3.16. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
21 |
Status |
F |
Date |
2007-11-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-01 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-11-01 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2007-11-01 15:22:06 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.01 REVISION SUBMITTED SHOWS THE LATEST | | | REVISION AS #13. REVISIONS 13 & 14 WERE APPROVED ON | | | 10-15-07. REVISION RETURNED. | | | | | | 2. SHT P2.05 KEY NOTE #13 NOT FOUND ON THE FLOOR PLAN. | | | SOME REVISIONS WERE FOUND THAT HAD NO CLOUDS OR DELTA | | | REVISION NUMBERS. PLEASE INDICATE ALL REVISIONS WITH | | | CLOUDS AND REVISION NUMBERS. SECTION 106.1.3. | | | | | | 3. SHT P2.17 PLANS AT THE TIME OF PERMIT SHOW REVISION | | | #6 DATED 8-7-06. SHEET SUBMITTED SHOWS A NEW REVISION | | | #6 DATED 4-27-07. FOR RECORD KEEPING A REVISION NUMBER | | | IS ONLY USED ONCE AND A PROGRESSIVE SEQUENCE WILL BE | | | USED. THE REVISION DATED 4-27-07 WAS NOT PREVIOUSLY | | | SUBMITTED AND IS NOT APPROVED. SECTION 106.1.3. | | | | | | 4. SHT P2.19 PLANS AT THE TIME OF PERMIT SHOW REVISION | | | #6 DATED 8-7-06. SHEET SUBMITTED SHOWS A NEW REVISION | | | #6 DATED 4-27-07. FOR RECORD KEEPING A REVISION NUMBER | | | IS ONLY USED ONCE AND A PROGRESSIVE SEQUENCE WILL BE | | | USED. THE REVISION DATED 4-27-07 WAS NOT PREVIOUSLY | | | SUBMITTED AND IS NOT APPROVED. SECTION 106.1.3.-- | | | ALSO SEE THE FOLLOWING COMMENTS FROM THE PREVIOUS | | | REVISION REVIEWS: --AS INDICATED IN THE REVISION | | | DENIAL DATED 07/07/07, SEE THE FOLLOWING COMMENTS STILL | | | NOT ADDRESSED: | | | ***2. SHT P2.19 A RELIEF VENT IS REQUIRED FOR THE AAV | | | TO THE SINK AT THE POOL DECK LEVEL. SECTION 917.3.2. | | | ALSO A REVISION WILL BE REQUIRED FOR THE SANITARY RISER | | | DIAGRAM TO REFLECT THE CHANGE TO THE SANT. SYSTEM. | | | SECTION 106.1.1.---KEY NOTES #12 THE OVERFLOW | | | FROM THE COLLECTOR TANKS SHALL DRAIN TO STORM, NOT | | | SANITARY.---REVISION #6 INDICATED AS COORD. REV. | | | 01-17-07. PLANS WERE ISSUED WITH A REVISION #6 "BLDG | | | DEPT COMM" 08-07-06. IN ORDER TO TRACK ALL REVISIONS, | | | ONLY ONE REVISION PER REVISION NUMBER WILL BE ALLOWED. | | | SECTION 106.1.3.**** | | | | | | 5. SHT P2.20 PLANS AT THE TIME OF PERMIT SHOW REVISION | | | #6 DATED 8-7-06. SHEET SUBMITTED SHOWS A NEW REVISION | | | #6 DATED 4-27-07. FOR RECORD KEEPING A REVISION NUMBER | | | IS ONLY USED ONCE AND A PROGRESSIVE SEQUENCE WILL BE | | | USED. THE REVISION DATED 4-27-07 WAS NOT PREVIOUSLY | | | SUBMITTED AND IS NOT APPROVED. SECTION 106.1.3.-- | | | ALSO THIS REVISION THE SANITARY PIPING IS NOT SHOWN AT | | | THE FIXTURES IN THE MEN'S AND WOMEN'S TOILET ROOMS AS | | | WELL AS AT THE DRINKING FOUNTAINS. PLEASE CLARIFY. | | | SECTION 106.1.1. | | | | | | ***********NOTE: THE PREVIOUSLY APPROVED REVISIONS ON | | | EACH SHEET SHALL BE TURNED OFF WHEN SUBMITTING | | | REVISIONS FOR REVIEW. THIS HAS BEEN REQUESTED QUITE A | | | FEW TIMES IN THE PAST BUT TO NO AVAIL. AS INDICATED | | | PREVIOUSLY THE REVIEW TURN AROUND TIME AND THE PROCESS | | | FOR REVISIONS IS SLOWED DOWN WHEN ONE HAS TO LOOK | | | THROUGH ALL CLOUDS AND ALL REVISION NUMBERS FOR ALL | | | REVISIONS, EVEN THOUGH MOST REVISIONS HAVE BEEN | | | PREVIOUSLY BEEN APPROVED. THE PREVIOUSLY APPROVED | | | REVISIONS ARE PART OF THE PLANS AND ARE NOT REVISIONS | | | AFTER THAT. --- P L E A S E TURN OFF ALL PREVIOUSLY | | | APPROVED REVISIONS WHEN SUBMITTING REVISIONS FOR | | | REVIEW. THANKING YOU IN ADVANCE FOR YOUR COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
20 |
Status |
P |
Date |
2007-11-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-01 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-30 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2007-11-01 14:56:01 | REVISIONS APPROVED. SHEETS P2.02, P2.04, P2.07, P2.08, | | | P2.10, P2.11, P2.13, P2.14, P2.16, P3.15. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
19 |
Status |
F |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-16 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-16 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2007-10-16 09:17:18 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.16 NOT ALL REVISIONS HAVE BEEN CLOUDED, NOR | | | DO ALL REVISIONS HAVE A REVISION NUMBER ATTACHED. | | | PLEASE INDICATE ALL CHANGES/REVISIONS WITH A CLOUD AND | | | A REVISION NUMBER. -- THE STORM LINE INDICATED BY KEY | | | NOTE NUMBER 17 HAS BEEN DELETED, BUT THE KEY NOTE IS | | | STILL SHOWN ON THE PLANS WHERE THE STORM LINE WAS | | | LOCATED. PLEASE CLARIFY. SECTION 106.1.1.**NOTE: THE | | | REVISION TURN AROUND TIME IS GREATLY INCREASED BECAUSE | | | OF THE FACT THAT PREVIOUS REVISION CLOUDS AND REVISION | | | NUMBER ARE STILL SHOWN ON THE PLANS. I HAVE ASKED | | | REPEATEDLY FOR ALL REVISIONS THAT HAVE BEEN PREVIOUSLY | | | APPROVED TO BE TURNED OFF. PLEASE COMPLY OR EXPLAIN WHY | | | THIS CAN NOT BE DONE. | | | | | | 2. SHT P2.19THE 4" ED, (1180SF). PLEASE IDENTIFY | | | WHICH ROOF DRAINS WILL ADD UP TO 1180SF.--THE 6" | | | ED, (1730SF). PLEASE IDENTIFY WHICH ROOF DRAINS WILL | | | ADD UP TO 1730SF.--6" ED, (3240SF). PLEASE IDENTIFY | | | WHICH ROOF DRAINS WILL ADD UP TO 3240SF.--4"ED, | | | (1300SF). PLEASE IDENTIFY WHICH ROOF DRAINS WILL ADD UP | | | TO 1300SF.--IF EACH DECK DRAIN HAS TO BE NUMBERED, | | | (DD-1, DD-2 ETC), AND THEN TIED TO A NUMBERED EMERGENCY | | | DRAIN, (ED-1, ED-2 ETC) TO CLARIFY WHICH DECK DRAINS | | | SQUARE FOOTAGE ADDS UP TO WHICH EMERGENCY DRAIN, THIS | | | WOULD HELP IN SHOWING ALL SQUARE FOOTAGE OF THE DECK | | | DRAINS IS ACCOUNTED FOR IN THE EMERGENCY DRAINS. -- KEY | | | NOTES #10 STATES "SEE SHT P2.20 FOR CONTINUATION". SHT | | | P2.20 DOES NOT SHOW THE CONTINUATION. PLEASE CLARIFY. | | | SECTION 106.1.1.--AS INDICATED IN THE REVISION | | | DENIAL DATED 07/07/07, SEE THE FOLLOWING COMMENTS STILL | | | NOT ADDRESSED: | | | ***2. SHT P2.19 A RELIEF VENT IS REQUIRED FOR THE AAV | | | TO THE SINK AT THE POOL DECK LEVEL. SECTION 917.3.2. | | | ALSO A REVISION WILL BE REQUIRED FOR THE SANITARY RISER | | | DIAGRAM TO REFLECT THE CHANGE TO THE SANT. SYSTEM. | | | SECTION 106.1.1.---KEY NOTES #12 THE OVERFLOW | | | FROM THE COLLECTOR TANKS SHALL DRAIN TO STORM, NOT | | | SANITARY.---REVISION #6 INDICATED AS COORD. REV. | | | 01-17-07. PLANS WERE ISSUED WITH A REVISION #6 "BLDG | | | DEPT COMM" 08-07-06. IN ORDER TO TRACK ALL REVISIONS, | | | ONLY ONE REVISION PER REVISION NUMBER WILL BE ALLOWED. | | | SECTION 106.1.3.**** | | | | | | 3. SHT P3.01 THE OVERFLOW FROM THE COLLECTOR TANKS FOR | | | THE POOL AND SPA SHALL DRAIN TO STORM, NOT SANITARY AS | | | SHOWN. | | | | | | 4. SHT P3.12 PD 310SF IS NOT SHOWN ON THE RISER DIAGRAM | | | FOR THAT AREA. (DP/3). PLEASE INDICATE WHAT RISER THE | | | PD CONNECTS TO. SECTION 106.1.2.--RISER DIAGRAM | | | DOES NOT REFLECT THE FLOOR PLAN FOR DP/4 WHERE THE | | | TRENCH DRAINS CONNECT TO THE BRANCH DRAIN. DD'S ON | | | STRUCTURAL SLAB CONNECT DOWNSTREAM OF THE TRENCH DRAINS | | | ON THE FLOOR PLAN.--2 DECK DRAINS INDICATED AS | | | BEING ON THE STRUCTURAL SLAB, BUT ALL 3 DECK DRAINS ARE | | | SHOWN ON THE SAME ELEVATION PER THE RISER DIAGRAM. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 5. 8-1/2" BY 11" REVISIONS SUBMITTED MIRROR THE | | | REVISIONS SUBMITTED ON SHEETS P2.01, P3.01, | | | P3.05,P2.16, P2.19 & P3.12 SO THESE ARE NOT REQUIRED. | | | THE AMOUNT OF SPACE REQUIRED FOR THE STORAGE OF PLANS | | | SUBMITTED FOR PUBLIC RECORD IS LIMITED AND DUPLICATE | | | INFORMATION NOT REQUIRED WILL NOT BE APPROVED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
18 |
Status |
P |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-16 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-15 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2007-10-16 08:49:16 | REVISION OK--SHT P2.01 & P3.05 (WATER HAMMER | | | ARRESTOR REQUIRED AT THE D/W PER SECTION 604.9) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
17 |
Status |
P |
Date |
2007-10-11 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-11 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-11 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2007-10-11 08:45:17 | SUBMITTAL FOR PRO-SLOPE APPROVED WITH REINFORCED 2" | | | ABOVE THE SHOWER PAN. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
16 |
Status |
F |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-13 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-13 |
Time |
14:27 |
Sent To |
B |
|
| Notes |
| 2007-09-13 14:33:12 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1. PRO-SLOPE SUBMITTAL DENIED. NO APPROVAL BY A | | | RECOGNIZED TESTING SHOWING COMPLIANCE WITH ALL CODES | | | FOR BUILDING MATERIALS.INDICATE REFERENCE STANDARD | | | PRODUCT BUILT TO AND SHOWAPPROVAL PER SECTIONS 303.2 | | | & 303.4. | | | | | | 2. SHOW COMPLIANCE WITH SECTION 417.5 REQUIREMENTS FOR | | | BEING IMPERVIOUS. IF THE PRO-SLOPE IS SHOWN TO COMPRESS | | | UNDER WEIGHT THIS WILL AFFECT THE REQUIREMENT. PLEASE | | | SHOW TESTING. | | | | | | 3. FLOORS OR RECEPTORS UNDER SHOWER COMPARTMENTS SHALL | | | BE LAID ON, AND SUPPORTED BY, A SMOOTH AND STRUCTURALLY | | | SOUND BASE. SECTION 417.5.1. PLEASE SUBMIT TESTING | | | SHOWING HOW THE ADVERTISED RATING OF 500LB PER SQUARE | | | FOOT WAS PROVEN. THE PRODUCT DOES NOT MEET THE INTENT | | | OF THE CODE THAT REQUIRES A UNIFORM SLOPE AT 1/4"/FT | | | BECAUSE NO TESTING HAS BEEN SHOWN TO INDICATE THAT THE | | | PRO-SLOPE WILL NOT COMPRESS AND LEAVE DIPS IN THE | | | PRODUCT AND ULTIMATELY CRACKING IN THE TILE. | | | | | | | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
15 |
Status |
F |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-20 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-20 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2007-07-20 11:13:59 | DENIED | | | REFERENCE: FBC-2001 PLUMBING | | | | | | 1. PRO-SLOPE SUBMITTAL DENIED. NO APPROVAL OR | | | INSTALLATION REQUIREMENTS INDICATED ON MANUF. | | | SPECIFICATION SHEETS. INDICATE REFERENCE STANDARD | | | PRODUCT BUILT TO AND APPROVAL PER SECTIONS 303.2 & | | | 303.4 | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
14 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-20 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-20 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2007-07-20 11:09:05 | SUBMITTAL OK FOR THE SHOWER CURB AND THE SHOWER PAN | | | MATERIAL |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
13 |
Status |
P |
Date |
2007-07-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-07 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-07 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2007-07-07 16:40:48 | REVISION APPROVED.SHTS P2.01, P2.02, P2.04, P2.07, | | | P2.08, P2.08. P2.11, P2.14, P2.16, P2.32. | | | | | | | | | | | | | | | PASSED PROVISO: REVISION REQUIRED FOR CONDENSATE RISER | | | TO REFLECT THE CHANGES. | | | | | | | | | | | | | | | | | | | | | PASSED PROVISO: REVISIONS REQUIRED TO CONDENSATE, | | | SANITARY & WATER RISERS TO REFLECT THE CHANGES. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
12 |
Status |
F |
Date |
2007-07-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-07 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-06 |
Time |
18:50 |
Sent To |
|
|
| Notes |
| 2007-07-07 16:14:18 | REVISIONDENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.17 INDICATES REVISION #6 "OWNER REQ. | | | REVISION" DATED 4-25-07. PLANS WERE ISSUED WITH A | | | REVISION #6 "BLDG DEPT COMM" DATED 8-07-06. IN ORDER TO | | | TRACK ALL REVISIONS, ONLY ONE REVISION PER REVISION | | | NUMBER WILL BE ALLOWED. SECTION 106.1.3.--(NOTE THE | | | REVIEW TIME IS INCREASED GREATLY WHEN ALL PREVIOUS | | | APPROVED REVISION CLOUDS & REVISION TRIANGLE NUMBERS | | | ARE STILL SHOWN ON EACH REVISION. ALSO IF THE | | | BACKGROUND INFORMATION SUCH AS WALLS, CORRIDORS, DOORS, | | | FIXTURES ETC. COULD BE LIGHTENED AS WELL AS PREVIOUS | | | PIPING AND WITH THE APPLIED REVISION IN BOLD THE | | | REVISIONS CAN BE EXPEDITED QUICKER). | | | | | | 2. SHT P2.19 A RELIEF VENT IS REQUIRED FOR THE AAV TO | | | THE SINK AT THE POOL DECK LEVEL. SECTION 917.3.2. ALSO | | | A REVISION WILL BE REQUIRED FOR THE SANITARY RISER | | | DIAGRAM TO REFLECT THE CHANGE TO THE SANT. SYSTEM. | | | SECTION 106.1.1.---KEY NOTES #12 THE OVERFLOW | | | FROM THE COLLECTOR TANKS SHALL DRAIN TO STORM, NOT | | | SANITARY.---REVISION #8 IS SHOWN ON THE FLOOR | | | PLAN, BUT NOT INDICATED ON THE REVISION INDEX. PLEASE | | | CLARIFY. SECTION 106.1.3.---REVISION #6 INDICATED | | | AS COORD. REV. 01-17-07. PLANS WERE ISSUED WITH A | | | REVISION #6 "BLDG DEPT COMM" 08-07-06. IN ORDER TO | | | TRACK ALL REVISIONS, ONLY ONE REVISION PER REVISION | | | NUMBER WILL BE ALLOWED. SECTION 106.1.3.---DECK | | | DRAINS ARE ALSO IDENTIFIED AS FD. PLEASE CLARIFY AS | | | FLOOR DRAINS ARE NOT APPROVED STORM DRAINS. SECTION | | | 106.1.1.--- THE EMERGENCY (SECONDARY) ROOF DRAINS | | | HAVE BEEN REDUCED IN CAPACITY & ARE NOT SIZED TO DRAIN | | | ALL SQUARE FOOTAGE OF ALL AREAS OF THE DECK. SECONDARY | | | ROOF DRAINS ARE REQUIRED FOR ALL SECTIONS OF THE DECK, | | | INCLUDING THE PATIO AREAS PER SECTION 1107.3. SHOW THE | | | SIZE OF EACH SECONDARY ROOF DRAINAND INDICATE SQUARE | | | FOOTAGE DRAINED BY EACH SECONDARY ROOF DRAIN. | | | | | | 3. SHT P2.20 REVISION #6 "OWNER REQD. REV 4-27-07. | | | PLANS WERE ISSUED WITH A REVISION #6 "BLDG DEPT COMM" | | | DATED 8-07-06. IN ORDER TO TRACK ALL REVISIONS, ONLY | | | ONE REVISION PER REVISION NUMBER WILL BE ALLOWED. | | | SECTION 106.1.3.---DECK DRAINS ARE ALSO | | | IDENTIFIED AS FD. PLEASE CLARIFY AS FLOOR DRAINS ARE | | | NOT APPROVED STORM DRAINS. SECTION 106.1.1.--- THE | | | EMERGENCY (SECONDARY) ROOF DRAINS HAVE BEEN REDUCED IN | | | CAPACITY & ARE NOT SIZED TO DRAIN ALL SQUARE FOOTAGE OF | | | ALL AREAS OF THE DECK. SECONDARY ROOF DRAINS ARE | | | REQUIRED FOR ALL SECTIONS OF THE DECK, INCLUDING THE | | | PATIO AREAS PER SECTION 1107.3. SHOW THE SIZE OF EACH | | | SECONDARY ROOF DRAINAND INDICATE SQUARE FOOTAGE | | | DRAINED BY EACH SECONDARY ROOF DRAIN. | | | | | | 4. SHT P2.31 REVISION #1 HAS BEEN DELETED FROM THE | | | REVISION INDEX. PLEASE CLARIFY.---REVISIONS #2 | | | HAS BEEN CHANGED TO REVISION #4 ON THE REVISION INDEX. | | | PLEASE CLARIFY. REVISION NUMBERS SHALL REMAIN THE SAME | | | THROUGHOUT THE LIFE OF THE PLANS IN ORDER TO BE ABLE TO | | | TRACK ALL CHANGES TO THE STAMPED SET OF REVIEWED PLANS. | | | SECTION 106.1.3.---REVISION #7 SHOWN ON THE ROOF | | | PLAN, BUT NOT SHOWN ON THE REVISION INDEX. PLEASE | | | CLARIFY.---KEY NOTES 4 & 5 ARE NOT CLOUDED OR | | | INDICATED AS REVISIONS WITH A REVISION NUMBER. PLEASE | | | CLOUD AND NUMBER ALL REVISIONS.---REVISION #6 & | | | KEY NOTE #3 STATES CONDENSATE PIPING TO TURN DOWN TO | | | FLOOR BELOW, BUT IS SHOWN TURNED DOWN ON THE ROOF. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 5. SHT P2.33A 3" VTR IS SHOWN UNDER RTU-5. THIS WILL | | | NEED TO BE OFFSET 10' PAST AIR INTAKE. SECTION 904.5. | | | ---VTR OFFSET & CONDENSATE LINE FROM RTU-5 IS NOT | | | CLOUDED NOR INDICATED AS A REVISIONS WITH A REVISION | | | NUMBER. PLEASE CLARIFY. ---REVISION #2 HAS BEEN | | | DELETED FROM THE REVISION PLEASE CLAIFY.--- REVISION | | | #2 HAS BEEN CHANGED TO REVISION #3 AT COL. LINE 23/I-G. | | | ---REVISION #3 HAS BEEN CHANGED TO REVISION #4 AT | | | COL. LINE 22/I.---REVISION #4 HAS BEEN CHANGED TO | | | REVISION #5 AT COL. LINE 23/G-D.-TO TRACK REVISIONS | | | AND TO KEEP PUBLIC RECORDS, THE REVISION NUMBERS SHALL | | | STAY THE SAME THROUGH THE LIFE OF THE JOB/PLANS. | | | SECTION 106.1.3. | | | | | | 6. SHT P3.12 RISER DP/4 THE SHOWER DECK DRAIN IS NOT | | | SHOWN, THE SQUARE FOOTAGE FOR TWO DECK DRAINS DOES NOT | | | REFLECT THE FLOOR PLAN, AND THE PIPING TO DECK DRAIN | | | (140SF) DOES NOT REFLECT THE FLOOR PLAN NOR DOES THE | | | BRANCH PIPING AT THE OFFSET UPSTREAM OF SAID DD.--- | | | DOWNSTREAM OF THE BASE OF RISER DP/5 DECREASES TO 4" | | | FROM 6" RISER. THIS IS NOT APPROVED. SECTION 704.2. | | | | | | 7. SHT P3.14 DETAIL 2 (EMERGENCY DRAINS) IS NOT | | | APPROVED. THE SECONDARY ROOF SYSTEM DRAINS SHALL DRAIN | | | THE TOTAL AREA EQUIVALENT TO THE AREA DRAINED GY THE | | | TOTAL OF ALL PRIMARY ROOF DRAINS. SECTION 1107.3. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
11 |
Status |
P |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-12 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-12 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2007-06-12 11:15:02 | SUBMITTAL APPROVED PRO-PRESS SYSTEM FOR COPPER PIPE | | | SYSTEMS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
10 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-04-26 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-04-26 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2007-04-26 13:29:21 | REVISION OK--SHT P2.04 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
9 |
Status |
F |
Date |
2007-02-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-26 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-26 |
Time |
18:51 |
Sent To |
|
|
| Notes |
| 2007-02-26 18:56:23 | REVISION DENIED | | | REFERENCE: FBC-2001 PLUBMING | | | FBC-2001 CHAPTER 1 | | | | | | SHT P2.04 REVISION NUMBER 10 IS NOT INDICATED ON THE | | | REVISION SCHEDULE.- -SOME CHANGES ARE NOT CLOUDED | | | OR NUMBERED.- -KEY NOTES NUMBER 10 IS NOT FOUND.- | | | -KEY NOTE NUMBER 9 INDICATES REVISION NUMBER 5. THIS | | | IS A PREVIOUS REVISION NUMBER FROM A PAST REVIEW.- - | | | TO HELP EXPEDITE FUTURE REVISIONS, PLEASE TURN OFF ALL | | | PREVIOUSLY APPROVED REVISION NUMBERS AND CLOUDS. | | | SECTION 104.2.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
8 |
Status |
P |
Date |
2007-02-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-02-26 |
Time |
18:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-02-26 |
Time |
18:49 |
Sent To |
|
|
| Notes |
| 2007-02-26 18:51:23 | REVISION OK SHTS P2.01 REV 11, SHT P3.01 REV 7, SHT | | | P3.02 REV 7, SHT P3.08 REV 11, SHT P3.09 REV 11 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
7 |
Status |
F |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-09 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-09 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2007-01-09 11:11:23 | REVISION FAILED | | | REFERENCE: FBC-2004 CHAPTER 1 | | | | | | 1. SHT P2.04 INDICATES REVISION #5 FOR KEY NOTES #9 | | | ADDED. REVISION #5 WAS INDICATED ON SHEETS APPROVED | | | DATED 9-8-06. NEW REVISION NUMBERS ARE REQUIRED FOR NEW | | | REVISIONS. - REVISION #10 IS NOT INDICATED ON THE LIST | | | OF REVISIONS.PLEASE CLARIFY. - KEY NOTE #10 NOT | | | LOCATED. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
6 |
Status |
P |
Date |
2007-01-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-01-09 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-01-08 |
Time |
16:32 |
Sent To |
|
|
| Notes |
| 2007-01-09 11:02:10 | REVISION OK - | | | SHT P2.01 OK - REVISIONS REQUIRED FOR THE SANITARY | | | COLLECTION ISOMETRIC TO REFLECT THE REVISIONS | | | APPROVED. | | | SHT P2.02 OK - REVISIONS REQUIRED FOR THE SANT. & STORM | | | COLLECTION ISOMETRICS TO REFLECT THE REVISIONS | | | APPROVED. | | | SHT P2.05 OK, SHT P2.28 OK, SHT P2.29 OK, SHT P3.03 OK, | | | SHT P3.04 OK, SHT P3.08 OK, SHT P3.09 OK, SHT P3.16 OK | | | UNIONS REQUIRED BY REGULATORS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2006-08-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-28 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-26 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2006-08-28 00:00:00 | SEE PROVISO ON GAS STOP |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
F |
Date |
2006-08-22 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-22 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-22 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2006-08-22 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE WPB | | | | | | ** **FROM PREVIOUS REVIEWS: THE COMMENT | | | NUMBERS SHALL REMAIN THE SAME AS THE | | | PREVIOUS REVIEWS: | | | | | | FROM PREVIOUS REVIEW: THE COMMENT | | | NUMBERS SHALL REMAIN THE SAME AS FIRST | | | REVIEW: - NO COMMENT RESPONSES SUBMITTED | | | FOR THE FIRST REVIEW. | | | | | | 2. OK | | | | | | 3. SHT A1.0 THE DRINKING FOUNTAIN SHALL | | | BE ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTIONS 11-4.15 AND ALL | | | SUBSECTIONS AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. | | | ***COMMENT CONCERNING 11-4.1.3(10)(A) | | | NOT ADDRESSED. CLEAR FLOOR SPACE SHALL | | | ALLOW FORWARD APPROACH. 11-4.15.5(1). | | | ****RESPONSE NOTED, BUT PARALLEL | | | APPROACH IS STILL SHOWN ON THE FLOOR | | | PLANS ON DIFFERENT SHEETS. | | | ** **RESPONSE NOTED, BUT A PARALLEL | | | APPROACH IS STILL SHOWN ON THE FLOOR | | | PLANS FOR SHEETS A0.3, A0.9, AND A1.21. | | | | | | 4. SHT A1.2 MEN'S & WOMEN'S TOILET ROOMS | | | SHALL BE ACCESSIBLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTIONS | | | 11-4.16, 11-4.19, 11-4.21, 11-4.22 AND | | | ALL SUBSECTIONS. ALSO FOR THE BREAK ROOM | | | SINK, 11-4.24 AND ALL SUBSECTIONS. | | | ***COMMENT NOT ADDRESSED. SEE COMMENT | | | NUMBER 2 FOR INFORMATION STILL REQUIRED | | | FOR W/C'S AND LAVS. | | | FOR SHOWERS | | | A. 11-4.21.3 SEAT (FOLD-UP TYPE) | | | B. 11-4.21.5 CONTROLS (FIG. 11-37) | | | C. 11-4.21.6 SHOWER UNIT | | | D. 11-4.21.7 CURBS | | | SUBMIT ELEVATIONS FOR THE SHOWER SHOWING | | | COMPLIANCE FOR THE PRIOR REQUIREMENTS. | | | ****RESPONSE NOTED, BUT THE SHOWER UNIT | | | REQUIRED BY 11-4.21.6 IS NOT SHOWN, AND | | | CURBS ARE INDICATED, WHERE AS SECTION | | | 11-4.21.7 INDICATES CURBS ARE NOT TO BE | | | INSTALLED. - NO BREAK ROOM SINK DETAIL | | | OR ELEVATION IS FOUND. - | | | DOORS SHALL NOT SWING INTO THE CLEAR | | | FLOOR SPACE REQUIRED FOR ANY FIXTURE. | | | THE SHOWER SHALL SHOW A CLEAR FLOOR | | | SPACE PER 11-4.21.2. SECTION | | | 11-4.22.2(1). | | | ** **RESPONSE NOTED, BUT THE FOLLOWING | | | INFORMATION IS REQUIRED FOR THE BREAK | | | ROOM SINK: | | | A. 11-4.24.2 HEIGHT | | | B. 11-4.24.3 KNEE CLEARANCE | | | C. 11-4.24.4 SINK DEPTH | | | D. 11-4.24.6 EXPOSED PIPES & SURFACES | | | E. 11-4.24.7 FAUCETS | | | | | | 5.OK | | | 6.OK | | | 11. OK | | | | | | 12. SHTS A9.2 THRU A9.24 ALL UNITS. | | | CLEAR FLOOR SPACE FOR THE WATER CLOSETS | | | SHALL BE APPLIED OR SUPERIMPOSED OVER A | | | PLAN PER PAGE 7.43 PARAGRAPH ONE. | | | ***COMMENT NOT ADDRESSED. | | | ****THIS ISSUE HAS NOT BEEN ADDRESSED. | | | CLEAR FLOOR SPACE FOR THE LAV & TUB ARE | | | SHOWN BUT NOT THE W/C. | | | ** **RESPONSE NOTED, BUT A 30"X48" CLEAR | | | FLOOR SPACE HAS BEEN SUPERIMPOSED ON THE | | | PLANS WHICH DOES NOT REFLECT THE CLEAR | | | FLOOR SPACES REQUIRED ON PAGE 7.43. | | | | | | 13. SHTS A9.2 THRU A9.24 PER PAGE 7.7 | | | MINIMUM CLEARANCES BETWEEN COUNTERS AND | | | ALL OPPOSING ELEMENTS IS 40". PLEASE | | | INDICATE ON THE PLANS THE MINIMUM | | | CLEARANCE FOR ALL KITCHENS. | | | ***COMMENT NOT ADDRESSED. | | | ****RESPONSE NOTED, BUT THE CLEARANCE | | | SHOWN IS NOT THE MINIMUM CLEARANCE. (SEE | | | ATTACHED SHEET FROM FHA DESIGN MANUAL). | | | ** **RESPONSE NOTED, BUT THIS DOES NOT | | | COMPLY WITH THE REQUIREMENT FOR THE | | | MINIMUM CLEARANCE. | | | | | | 14. OK | | | 15. OK | | | 19. OK | | | 23. OK | | | 26. OK | | | 30. SOK | | | 31. OK | | | 32. OK - TO BE A SUBMITTAL | | | 33. OK | | | 35. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | **************NEW COMMENTS************** | | | | | | 1B. OK | | | 2B. OK | | | 3B. OK | | | 4B. OK | | | 5B. OK | | | 6B. OK | | | 7B. OK | | | 8B. OK | | | 9B. OK | | | 10B. OK | | | 11B. OK | | | 12B. OK | | | 13B. OK | | | 14B. OK | | | 15B. OK | | | 16B. OK | | | 17B. OK | | | 18B. OK | | | 19B. OK | | | 20B. OK | | | 21B. OK | | | 22B. OK | | | 23B. OK | | | 24B. OK | | | 25B. OK | | | 26B. OK | | | 27B. OK | | | 28B. OK | | | 29B. OK | | | 30B. OK | | | 31B. OK | | | 32B. OK | | | 33B. OK | | | | | | 34B. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS PERMIT: | | | A. OK | | | B. OK | | | C. OK | | | | | | D. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. (EACH SYSTEM). | | | ****NOT ADDRESSED. | | | ** **RESPONSE NOTED, THE GAS WILL NOT BE | | | APPROVED ON THESE PLANS UNTIL ALL | | | REQUIREMENTS ARE MET. GAS PLANS CAN BE | | | DELETED AND RESUBMITTED AT TIME OF GAS | | | APPLICATION. | | | | | | E. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (EACH SYSTEM). | | | ****NOT ADDRESSED. | | | ** **RESPONSE NOTED, THE GAS WILL NOT BE | | | APPROVED ON THESE PLANS UNTIL ALL | | | REQUIREMENTS ARE MET. GAS PLANS CAN BE | | | DELETED AND RESUBMITTED AT TIME OF GAS | | | APPLICATION. | | | | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. (EACH | | | SYSTEM). | | | ****NOT ADDRESSED. ITS UNDERSTOOD THE | | | KITCHEN GAS EQUIPMENT WILL BE SUBMITTED | | | AT KITCHEN BUILD-OUT, BUT THE POOL | | | HEATER SPECIFICATIONS SHEETS WILL BE | | | REQUIRED. | | | ** **RESPONSE NOTED, THIS ISSUE CAN BE | | | TAKEN CARE OF AT THE TIME OF GAS | | | APPLICATION. | | | | | | G. AT TIME OF KITCHEN BUILD OUT | | | | | | 35B. THERE IS ONE SET OF "RED LINED" | | | PLANS. PLEASE RETURN THIS SET AND | | | COMMENT RESPONSES TO HELP EXPEDITE THE | | | NEXT PLAN REVIEW. | | | ****COMMENT NOT ADDRESSED. | | | | | | **************NEW COMMENTS************** | | | | | | 1C. OK | | | 2C. OK | | | 3C. OK | | | | | | 4C. EMERGENCY DRAINS FOR THE DECK SHALL | | | DRAIN THE TOTAL AREA OF THE DRAIN. SOME | | | AREAS HAVE NO EMERGENCY DRAINS, AND ITS | | | UNDERSTOOD THAT THOSE AREAS WILL DRAIN | | | TO THE EMERGENCY DRAINS SHOWN. THE | | | EMERGENCY DRAINS SHALL BE SIZED FOR THE | | | TOTAL AREA THAT WILL BE DRAINED FOR EACH | | | AREA. PLEASE INDICATE THE TOTAL AREA | | | BEING DRAINED FOR EACH EMERGENCY DRAIN | | | AND SIZE ED'S ACCORDINGLY. SECTION | | | 1107.3. | | | ** **RESPONSE NOTED, BUT THE AREAS FOR | | | MOST EMERGENCY ROOF DRAINS DOES NOT ADD | | | UP TO THE SURRONDING AREAS. PLEASE | | | RECHECK THE AREAS AND CHECK THE TOTAL | | | SQUARE FOOTAGE FOR EACH EMERGNECY DRAIN | | | AREA. PLEASE NUMBER EACH EMERGENCY DRAIN | | | AND NUMBER AND OUTLINE EACH AREA | | | DRAINING TO EACH EMERGENCY DRAIN FOR | | | CLARITY. - ALSO RECHECK ALL PIPE SIZES | | | AND ROOF DRAIN SIZES AS NOT ALL ARE | | | CORRECT. SEE TABLE 1106.3 @ 4.5"/HR | | | RAINFALL FOR SECONDARY ROOF DRAINS. | | | (EXAMPLE ED 2914 SF ADDS UP TO 2804SF, | | | 4"RD SHOWN, 5"RD REQUIRED, 6" HORIZONTAL | | | PIPE SHOWN, 8" HORIZONTAL PIPE | | | REQUIRED). | | | | | | **************NEW COMMENT************** | | | | | | 1D. SHT A1.18 AREA FROM COL. LINE M TO | | | AREA BETWEEN COL'S P & Q FROM COL. 11 | | | THRU COL. 19 FLOOR PLAN IS MISSING. | | | PLEASE RESUBMIT SHEET WILL ALL REQUIRED | | | INFORMATION. CHECK TO SEE IF ALL | | | INFORMATION IS CORRECT IN THIS AREA. | | | SECTION 106.1.1. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2006-08-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-08-04 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-08-02 |
Time |
18:58 |
Sent To |
|
|
| Notes |
| 2006-08-04 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 FUEL GAS | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE WPB | | | | | | FROM PREVIOUS REVIEW: THE COMMENT | | | NUMBERS SHALL REMAIN THE SAME AS FIRST | | | REVIEW: - NO COMMENT RESPONSES SUBMITTED | | | FOR THE FIRST REVIEW. | | | | | | 2. OK | | | | | | 3. SHT A1.0 THE DRINKING FOUNTAIN SHALL | | | BE ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTIONS 11-4.15 AND ALL | | | SUBSECTIONS AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. | | | ***COMMENT CONCERNING 11-4.1.3(10)(A) | | | NOT ADDRESSED. CLEAR FLOOR SPACE SHALL | | | ALLOW FORWARD APPROACH. 11-4.15.5(1). | | | ****RESPONSE NOTED, BUT PARALLEL | | | APPROACH IS STILL SHOWN ON THE FLOOR | | | PLANS ON DIFFERENT SHEETS. | | | | | | 4. SHT A1.2 MEN'S & WOMEN'S TOILET ROOMS | | | SHALL BE ACCESSIBLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTIONS | | | 11-4.16, 11-4.19, 11-4.21, 11-4.22 AND | | | ALL SUBSECTIONS. ALSO FOR THE BREAK ROOM | | | SINK, 11-4.24 AND ALL SUBSECTIONS. | | | ***COMMENT NOT ADDRESSED. SEE COMMENT | | | NUMBER 2 FOR INFORMATION STILL REQUIRED | | | FOR W/C'S AND LAVS. | | | FOR SHOWERS | | | A. 11-4.21.3 SEAT (FOLD-UP TYPE) | | | B. 11-4.21.5 CONTROLS (FIG. 11-37) | | | C. 11-4.21.6 SHOWER UNIT | | | D. 11-4.21.7 CURBS | | | SUBMIT ELEVATIONS FOR THE SHOWER SHOWING | | | COMPLIANCE FOR THE PRIOR REQUIREMENTS. | | | ****RESPONSE NOTED, BUT THE SHOWER UNIT | | | REQUIRED BY 11-4.21.6 IS NOT SHOWN, AND | | | CURBS ARE INDICATED, WHERE AS SECTION | | | 11-4.21.7 INDICATES CURBS ARE NOT TO BE | | | INSTALLED. - NO BREAK ROOM SINK DETAIL | | | OR ELEVATION IS FOUND. - | | | DOORS SHALL NOT SWING INTO THE CLEAR | | | FLOOR SPACE REQUIRED FOR ANY FIXTURE. | | | THE SHOWER SHALL SHOW A CLEAR FLOOR | | | SPACE PER 11-4.21.2. SECTION | | | 11-4.22.2(1). | | | | | | 5. SHT A1.18 MEN'S AND WOMEN'S LOCKER | | | ROOMS TO BE ACCESSABLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTION 11-4.16, | | | 11-4.18, 11-4.19, 11-4.21, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | ***COMMENT NOT ADDRESSED. SEE COMMENT | | | NUMBER TWO FOR INFORMATION STILL | | | REQUIRED. ALSO THE INFORMATION FOR THE | | | URINAL STILL REQUIRED: | | | A. 11-4.18.2 HEIGHT | | | B. 11-4.18.4 FLUSH CONTROLS | | | ****RESPONSE NOTED, BUT NO COMPLIANCE | | | FOR THE FLUSH CONTROLS IS INDICATED. | | | | | | 6.OK | | | 11. OK | | | | | | 12. SHTS A9.2 THRU A9.24 ALL UNITS. | | | CLEAR FLOOR SPACE FOR THE WATER CLOSETS | | | SHALL BE APPLIED OR SUPERIMPOSED OVER A | | | PLAN PER PAGE 7.43 PARAGRAPH ONE. | | | ***COMMENT NOT ADDRESSED. | | | ****THIS ISSUE HAS NOT BEEN ADDRESSED. | | | CLEAR FLOOR SPACE FOR THE LAV & TUB ARE | | | SHOWN BUT NOT THE W/C. | | | | | | 13. SHTS A9.2 THRU A9.24 PER PAGE 7.7 | | | MINIMUM CLEARANCES BETWEEN COUNTERS AND | | | ALL OPPOSING ELEMENTS IS 40". PLEASE | | | INDICATE ON THE PLANS THE MINIMUM | | | CLEARANCE FOR ALL KITCHENS. | | | ***COMMENT NOT ADDRESSED. | | | ****RESPONSE NOTED, BUT THE CLEARANCE | | | SHOWN IS NOT THE MINIMUM CLEARANCE. (SEE | | | ATTACHED SHEET FROM FHA DESIGN MANUAL) | | | | | | 14. OK | | | 15. OK | | | 19. OK | | | 23. OK | | | 26. OK | | | 30. SOK | | | 31. OK | | | 32. OK - TO BE A SUBMITTAL | | | | | | 33. GREASE INTECEPTOR SHALL BE SIZED BY | | | THE ENVIRONMENTAL COMPLIANCE MANAGER. | | | PLEASE CONTACT LYNN MASSON (561) | | | 822-2271 OR BY FAX (561) 822-2279 OR BY | | | E-MAIL [email protected]. | | | ***NOT ADDRESSED. | | | ****WAITING FOR APPROVAL FROM L. MASSON | | | | | | | | | 35. PLANS SHOW A VENT IN THE WALL AND AN | | | OPEN 2" DRAIN IN THE PLENUM. MORE | | | INFORMATION IS REQUIRED. WILL THE ROOM | | | AS A PLENUM PULL THE AIR FROM THE 2" | | | OPEN DRAIN AND INTRODUCE THE HUMID, WARM | | | AIR INTO THE AIR CONDITIONED AIR OF THE | | | UNIT? IS THIS PRACTICE ACCEPTABLE TO THE | | | MECHNAICAL ENGINEER? - ALSO THE VENT | | | TERMINATION SHALL EITHER VENT THRU THE | | | ROOF OR TERMINATE ABOVE THE CEILING 6" | | | ABOVE THE INSULATION. | | | ***NOT ADDRESSED. | | | ****RESPONSE NOTED, BUT VENT IS STILL | | | SHOWN IN THE WALL, AND THE DRAIN IS | | | STILL SHOWN ALSO. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | ***NO COMMENT RESPONSE WAS SUBMITTED AND | | | BECAUSE OF THAT AND PLAN DEVELOPMENT | | | BETWEEN REVIEWS, THE RESUBMITTAL WAS | | | TREATED AS A COMPLETE REVIEW OF THE | | | PLAN. THIS CONTRIBUTES TO A LONGER TURN | | | AROUND TIME FOR PLAN REVIEW. | | | | | | **************NEW COMMENTS************** | | | | | | 1B. OK | | | 2B. OK | | | 3B. OK | | | 4B.OK | | | 5B. OK | | | | | | 6B. SHT P2.06 SHOWS RWL/35 BETWEEN COLS. | | | 28.1 AND 29. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | ****RESPONSE NOTED, BUT RWL 35 STILL | | | SHOWN. | | | | | | 7B. OK | | | 8B. OK | | | | | | 9B. SHT P2.20 3"PD(68SF) & 3"PD(92SF) | | | ARE NOT SHOWN ON ANY RISER DIAGRAM. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | ****RESPONSE NOTED, BUT NOW 68SF IS NOT | | | SHOWN ON THE PLUMBING PLAN, & 92SF IS | | | NOT SHOWN ON THE RISER DIAGRAM. PLEASE | | | CORRELATE. | | | | | | 10B. OK | | | 11B. OK | | | | | | 12B. SHTS P2.23 & P2.24 MATCH LINE DOES | | | NOT MATCH FLOOR PLAN AT COL. LINE "22". | | | PLEASE CLARIFY. SECTION 106.1.1. | | | ****RESPONSE NOTED, BUT THERE IS MISSING | | | INFORMATION FOR THE FLOOR PLAN ON SHT | | | P2.23. | | | | | | 13B. OK | | | 14B. OK | | | 15B. OK | | | 16B. OK | | | 17B. OK | | | | | | 18B. SHT P3.01 RECHECK ADDITION OF DFU'S | | | AS THEY ACCUMULATE IN THE SANT. SYSTEM. | | | TABLE 710.1(1). | | | ****RESPONSE NOTED, BUT ADDITION OF | | | DFU'S INCORRECT IN SOME AREAS. | | | | | | 19B. OK | | | 20B. OK | | | 21B. OK | | | 22B. OK | | | 23B. OK | | | | | | 24B. SHT P3.06 2 W/4 RISERS SHOWN, 2 | | | W/11 RISERS SHOWN, 2 W/8 RISERS SHOWN & | | | 2 W/28 RISERS SHOWN. PLEASE CORRELATE | | | RISER DIAGRAM WITH FLOOR PLAN. | | | ****RESPONSE NOTED, BUT SHT P3.07 STILL | | | SHOWS 2 W/28 RISERS. | | | | | | 25B. OK | | | 26B. OK | | | 27B. OK | | | | | | 28B. SHT P3.13 3" PAD (136SF) NOT | | | INDICATED ON DECK PLAN. PLEASE | | | CORRELATE. SECTION 106.1.1. | | | ****RESPONSE NOTED, BUT 3" PAD (136SF) | | | STILL NOT FOUND. - NEW COMMENT NEW 2ND | | | 4" DD (378SF) SHOWN ON RISER NOT FOUND | | | ON DECK PLAN. | | | | | | 29B. SHT P3.14 6" REQUIRED AT SD | | | (1657SF). TABLE 1106.3. | | | ****RESPONSE NOTED, BUT PIPES ARE | | | UNDERSIZED DOWNSTREAM OF 4" DD (763SF) | | | RISER DP7, DOWNSTREAM OF 3" PD (134SF) | | | RISER DP8, & DOWNSTREAM OF 3" PD (81SF) | | | SHOWS 8" THEN REDUCING TO 6" IN THE | | | DIRECTION OF FLOW. SECTION 704.2. | | | | | | 30B. OK | | | 31B. OK | | | 32B. OK | | | 33B. OK | | | | | | 34B. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | ****RESPONSE NOTED, BUT THE GAS LINE TO | | | THE POOL HEATER APPEARS TO BE RUN IN THE | | | 5TH FLOOR CEILING. WILL THE POOL HEATER | | | BE LOCATED IN THE CEILING, OR WILL THERE | | | BE A DROP TO THE HEATER. PLEASE CLARIFY. | | | | | | B. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). (EACH SYSTEM). | | | ****RESPONSE NOTED, BUT THE TABLE SHOWN | | | IS FROM FBC-2001 FUEL GAS CODE. PLEASE | | | DESIGN AND INDICATE TABLE FROM FBC-2004 | | | FUEL GAS CODE. | | | C. OK | | | | | | D. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. (EACH SYSTEM). | | | ****NOT ADDRESSED. | | | | | | E. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (EACH SYSTEM). | | | ****NOT ADDRESSED. | | | | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. (EACH | | | SYSTEM). | | | ****NOT ADDRESSED. ITS UNDERSTOOD THE | | | KITCHEN GAS EQUIPMENT WILL BE SUBMITTED | | | AT KITCHEN BUILD-OUT, BUT THE POOL | | | HEATER SPECIFICATIONS SHEETS WILL BE | | | REQUIRED. | | | | | | G. AT KITCHEN BUILD-0UT | | | | | | 35B. THERE IS ONE SET OF "RED LINED" | | | PLANS. PLEASE RETURN THIS SET AND | | | COMMENT RESPONSES TO HELP EXPEDITE THE | | | NEXT PLAN REVIEW. | | | ****COMMENT NOT ADDRESSED. | | | | | | **************NEW COMMENTS************** | | | | | | 1C. CONDENSATE/PAN DRAIN LINE TO BE | | | SEPARATE. CONDENSATE LINES CAN BACK UP | | | BECAUSE OF THE BUILD-UP AND THE EXHAUST | | | FROM THE PARKING GARAGE CAN ENTER THE | | | A/C CLOSETS. PAN DRAIN LINES SHOULD | | | TERMINATE OUTSIDE THE BUILDING, OR BE | | | PIPED INDIRECTLY TO THE SANITARY SYSTEM. | | | SECTION 504.7.2. | | | | | | 2C. SHT P3.04 RISER 139 WASH MACHINE TO | | | DISCHARGE DOWNSTREAM OF BATHROOM | | | FIXTURES. VENT REQUIRED FOR W/C & | | | SHOWER. SECTIONS 901.2 & 909.1 | | | | | | 3C. SHT P3.04 RISER 98 FITTING TO BE | | | INSTALLED TO GUIDE SEWAGE AND WASTE IN | | | THE DIRECTION OF FLOW. SECTION 706.3. | | | | | | 4C. EMERGENCY DRAINS FOR THE DECK SHALL | | | DRAIN THE TOTAL AREA OF THE DRAIN. SOME | | | AREAS HAVE NO EMERGENCY DRAINS, AND ITS | | | UNDERSTOOD THAT THOSE AREAS WILL DRAIN | | | TO THE EMERGENCY DRAINS SHOWN. THE | | | EMERGENCY DRAINS SHALL BE SIZED FOR THE | | | TOTAL AREA THAT WILL BE DRAINED FOR EACH | | | AREA. PLEASE INDICATE THE TOTAL AREA | | | BEING DRAINED FOR EACH EMERGENCY DRAIN | | | AND SIZE ED'S ACCORDINGLY. SECTION | | | 1107.3. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2006-05-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2006-05-26 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2006-05-13 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2006-05-26 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | MUNICIPAL CODE WPB | | | | | | FROM PREVIOUS REVIEW: THE COMMENT | | | NUMBERS SHALL REMAIN THE SAME AS FIRST | | | REVIEW: - NO COMMENT RESPONSES SUBMITTED | | | FOR THE FIRST REVIEW. | | | | | | 2. SHT A1.0 MEN'S & WOMEN'S TOILET ROOMS | | | SHALL BE ACCESSIBLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTIONS | | | 11-4.16, 11-4.19, & 11-4.22 AND ALL | | | SUBSECTIONS. | | | *** COMMENT NOT ADDRESSED. SHOW THE | | | FOLLOWING: FOR W/C'S | | | A. 11-4.16.2 CLEAR FLOOR SPACE | | | B. 11-4.16.5 FLUSH CONTROLS | | | FOR LAVS | | | A. 11-4.19.2 CLEARANCES | | | B. 11-4.19.3 CLEAR FLOOR SPACE | | | C. 11-4.19.4 EXPOSED PIPES & SURFACES | | | D. 11-4.19.5 FAUCETS | | | | | | 3. SHT A1.0 THE DRINKING FOUNTAIN SHALL | | | BE ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTIONS 11-4.15 AND ALL | | | SUBSECTIONS AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. | | | ***COMMENT CONCERNING 11-4.1.3(10)(A) | | | NOT ADDRESSED. CLEAR FLOOR SPACE SHALL | | | ALLOW FORWARD APPROACH. 11-4.15.5(1). | | | | | | 4. SHT A1.2 MEN'S & WOMEN'S TOILET ROOMS | | | SHALL BE ACCESSIBLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTIONS | | | 11-4.16, 11-4.19, 11-4.21, 11-4.22 AND | | | ALL SUBSECTIONS. ALSO FOR THE BREAK ROOM | | | SINK, 11-4.24 AND ALL SUBSECTIONS. | | | ***COMMENT NOT ADDRESSED. SEE COMMENT | | | NUMBER 2 FOR INFORMATION STILL REQUIRED | | | FOR W/C'S AND LAVS. | | | FOR SHOWERS | | | A. 11-4.21.3 SEAT (FOLD-UP TYPE) | | | B. 11-4.21.5 CONTROLS (FIG. 11-37) | | | C. 11-4.21.6 SHOWER UNIT | | | D. 11-4.21.7 CURBS | | | SUBMIT ELEVATIONS FOR THE SHOWER SHOWING | | | COMPLIANCE FOR THE PRIOR REQUIREMENTS. | | | | | | 5. SHT A1.18 MEN'S AND WOMEN'S LOCKER | | | ROOMS TO BE ACCESSABLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTION 11-4.16, | | | 11-4.18, 11-4.19, 11-4.21, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | ***COMMENT NOT ADDRESSED. SEE COMMENT | | | NUMBER TWO FOR INFORMATION STILL | | | REQUIRED. ALSO THE INFORMATION FOR THE | | | URINAL STILL REQUIRED: | | | A. 11-4.18.2 HEIGHT | | | B. 11-4.18.4 FLUSH CONTROLS | | | | | | 6. SHT A1.21 MEN'S & WOMEN'S TOILET | | | ROOMS AND DRINKING FOUNTAIN SHALL BE | | | ACCESSIBLE. (SEE COMMENTS 2, 3 & 5). | | | ***COMMENT NOT ADDRESSED. SEE COMMENT | | | NUMBER TWO FOR INFORMATION STILL | | | REQUIRED. | | | | | | 11. SHT A9.24 UNITS C1.1, C1.2, & C1 | | | OPENING FOR WATER CLOSET IN BATH #2 | | | SHALL BE MINIMUM 33" . PLEASE INDICATE | | | ON PLANS. PAGE 7.44. | | | ***COMMENT NOT ADDRESSED. | | | | | | 12. SHTS A9.2 THRU A9.24 ALL UNITS. | | | CLEAR FLOOR SPACE FOR THE WATER CLOSETS | | | SHALL BE APPLIED OR SUPERIMPOSED OVER A | | | PLAN PER PAGE 7.43 PARAGRAPH ONE. | | | ***COMMENT NOT ADDRESSED. | | | | | | 13. SHTS A9.2 THRU A9.24 PER PAGE 7.7 | | | MINIMUM CLEARANCES BETWEEN COUNTERS AND | | | ALL OPPOSING ELEMENTS IS 40". PLEASE | | | INDICATE ON THE PLANS THE MINIMUM | | | CLEARANCE FOR ALL KITCHENS. | | | ***COMMENT NOT ADDRESSED. | | | | | | 14. SHT P2.01 NO PIPING SHOWN TO 3 PAD'S | | | PLEASE CLARIFY. SECTION 106.1.1. SHOW | | | ALL PIPE SIZES FOR ALL PIPE SYSTEMS ON | | | THE THE FLOOR PLAN. TABLES 710.1 & | | | 1106.3. | | | ***PAD'S STILL SHOWN, BUT NOT | | | IDENTIFIED. PLEASE CLARIFY. - PIPE | | | SIZING NOT SHOWN ON FLOOR PLAN PIPING. | | | | | | 15. SHT P2.02NO PIPING SHOWN TO 2 | | | PAD'S. SECTION 106.1.1. - SHOW ALL PIPE | | | SIZING FOR U/G BUILDING SANT. , STORM, | | | COND., AND DRAIN PIPING. SECTION | | | 106.1.1. TABLES 710.1 & 1106.3. | | | ***PAD'S STILL SHOWN, BUT NOT | | | IDENTIFIED, PLEASE CLARIFY. SECTION | | | 106.1.1. | | | | | | 19. SHTS P2.19 & P2.20 SUBMIT | | | CALCULATIONS FOR PRIMARY AND SECONDARY | | | STORM DRAINS. SHOW SQUARE FEET, 1/2 AREA | | | OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS, AND AREA OF ROOFS DRAINING TO | | | DECK AREA FROM ABOVE IN THE CALCULATIONS | | | PER SECTIONS 1106 & 1107 WITH ALL | | | SUBSECITONS. - SHOW THE LOCATION OF ALL | | | SECONDARY DRAINS. | | | ***COMMENT NOT ADDRESSED. NO CALC'S | | | FOUND. SECONDARY DRAIN LOCATIONS NOT | | | SHOWN. CONTRIBUTION FROM THE PRIVACY | | | WALLS TO BOTH SIDES AT THE DECK AREAS | | | WERE NOT INDICATED. | | | | | | 23. SHT P3.02 2-WAY CLEANOUTS ARE | | | REQUIRED ON BOTH THE ENTRANCE AND EXIT | | | OF THE GREASE INTERCEPTOR PER UTILITY | | | STANDARDS. - FIXTURE UNIT VALUE NOT | | | SHOWN FOR 3 FUTURE STUB UPS. TABLE | | | 710.1(1). | | | ***2-WAY CLEANOUT NOT SHOWN ON THE INLET | | | SIDE OF THE GREASE INTERCEPTOR. - | | | FIXTURE UNIT VALUE STILL NOT SHOWN FOR | | | ALL FUTURE STUB UPS. | | | | | | 26. SHT P3.08 KEY NOTES INFORMATION IS | | | REVERSED FROM RISERS. PLEASE CORRELATE | | | KEY NOTES AND RISERS. SECTION 106.1.1. | | | ***THIS IS STILL NOT CHANGED ON ALL | | | RISERS. | | | | | | | | | 30. SHT P3.14 6PLEASE NUMBER | | | OR PLACE A DESIGNATION ON THE LIFT | | | STATIONS BOTH ON THE RISER DIAGRAMS AND | | | THE FLOOR PLANS TO HELP EXPEDITE THE | | | PLAN REVIEW. | | | ***NOT ADDRESSED. | | | | | | 31. SHT P3.15 RISER DOES NOT REFLECT THE | | | FLOOR PLAN. RISERS CD/37 & DR/37 ARE NOT | | | SHOWN ON THE RISER DIAGRAM. | | | ***NOT ADDRESSED. | | | 32. DOMESTIC BOOSTER PUMPS, STORM LIFT | | | STATION PUMPS SHALL BE LISTED. PLEASE | | | SUBMIT MANUF. SPECIFICATION SHEETS FOR | | | EACH. SECTION 303. | | | ***NOT ADDRESSED. | | | | | | 33. GREASE INTECEPTOR SHALL BE SIZED BY | | | THE ENVIRONMENTAL COMPLIANCE MANAGER. | | | PLEASE CONTACT LYNN MASSON (561) | | | 822-2271 OR BY FAX (561) 822-2279 OR BY | | | E-MAIL [email protected]. | | | ***NOT ADDRESSED. | | | | | | | | | 35. PLANS SHOW A VENT IN THE WALL AND AN | | | OPEN 2" DRAIN IN THE PLENUM. MORE | | | INFORMATION IS REQUIRED. WILL THE ROOM | | | AS A PLENUM PULL THE AIR FROM THE 2" | | | OPEN DRAIN AND INTRODUCE THE HUMID, WARM | | | AIR INTO THE AIR CONDITIONED AIR OF THE | | | UNIT? IS THIS PRACTICE ACCEPTABLE TO THE | | | MECHNAICAL ENGINEER? - ALSO THE VENT | | | TERMINATION SHALL EITHER VENT THRU THE | | | ROOF OR TERMINATE ABOVE THE CEILING 6" | | | ABOVE THE INSULATION. | | | ***NOT ADDRESSED. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | ***NO COMMENT RESPONSE WAS SUBMITTED AND | | | BECAUSE OF THAT AND PLAN DEVELOPMENT | | | BETWEEN REVIEWS, THE RESUBMITTAL WAS | | | TREATED AS A COMPLETE REVIEW OF THE | | | PLAN. THIS CONTRIBUTES TO A LONGER TURN | | | AROUND TIME FOR PLAN REVIEW. | | | | | | **************NEW COMMENTS************** | | | | | | 1B. SHT A9.27 DETAIL ELEVATIONS 3 & 5 NO | | | DISPENSER SHOWN. STALL DOES NOT REFLECT | | | FIG. 30E. LAV TO BE A MINIMUM 60" OFF | | | THE W/C WALL. (MIN. 15" OFF WALL TO | | | CENTERLINE OF LAV). WATER CLOSET TO BE | | | 17" TO 19" OFF FLOOR TO SEAT. INDICATE | | | ON PLANS. SHOW CLEARANCE FOR LAVS TO BE | | | 2'3". SECTIONS 11-4.16.3, 11-4.16.6, | | | 11-4.19.2, | | | | | | 2B. SHTS P2.01 THRU P2.0-5, P2.07, | | | P2.08, P2.10, P2.11, P2.13, P2.14, | | | P2.16, & P2.17 IDENTIFY ALL RISERS FOR | | | ALL SYSTEMS. SECTION 106.1.1. | | | | | | 3B. SHT P2.02 8" FD TO STORM IN MAINT. | | | ROOM. PLEASE INDICATE WHAT IS BEING | | | DRAINED. IF NOT STORM WATER, DRAIN TO BE | | | CONNECTED TO SANITARY. MUNICIPAL CODE | | | SECTION 90-203. | | | | | | 4B. SHT P2.03 FITTING CONNECTING 2" | | | DRAIN BETWEEN COLS. 28 & 29 TO BUILDING | | | SANT. FITTING IS NOT INSTALLED TO GUIDE | | | SEWAGE AND WASTE IN THE DIRECTION OF | | | FLOW AS REQUIRED IN SECTION 706.3. | | | | | | 5B. SHT P2.05 SHOWS 2 W/26 RISERS. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 6B. SHT P2.06 SHOWS RWL/35 BETWEEN COLS. | | | 28.1 AND 29. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | | | | 7B. SHTS P2.07, P2.10, & P2.13 SHOWS | | | RWL/18 BETWEEN COLS. 5 & 6. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | | | | 8B. SHT P2.19 4"DD (1,525SF) & 3"PD | | | (92SF) NOT SHOWN ON ANY RISER DIAGRAM. - | | | EXTRA FD SHOWN @ COL LINE 7 BETWEEN | | | COLS. O & N. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | | | | 9B. SHT P2.20 3"PD(68SF) & 3"PD(92SF) | | | ARE NOT SHOWN ON ANY RISER DIAGRAM. | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 10B. SHTS P2.22, P2.23, P2.24 INDICATES | | | "TYPICAL FLOOR". PLEASE INDICATE WHAT | | | ITS TYPICAL OF. SECTION 106.1.1. | | | | | | 11B. SHTS P2.22 & P2.23 MATCH LINE DOES | | | NOT MATCH FLOOR PLAN AT COL. LINE "N". | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 12B. SHTS P2.23 & P2.24 MATCH LINE DOES | | | NOT MATCH FLOOR PLAN AT COL. LINE "22". | | | PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 13B. SHTS P2.22 & P2.25 RISER | | | DESIGNATION FOR S/46 COVERED UP BY RISER | | | RWL/12 DESIGNATION. PLEASE INDICATE | | | CLEARLY RISER DESIGNATION S/46. SECTION | | | 106.1.1. | | | | | | 14B. SHT P2.26 WATER LINE FROM M/B TO | | | KITCHEN IN UNIT 'A 5.2' NOT ON PLANS. | | | SECTION 106.1.1. | | | | | | 15B. SHT P2.31 2 VTR'S IN EGRESS | | | STAIRWELL ARE NOT APPROVED. NFPA 101 | | | SECTION 7.1.3.2.1(6). | | | | | | 16B. SHTS P2.31, P2.32, P2.33 PLEASE | | | IDENTIFY ROOF DRAINS WITH A NUMBER | | | DESIGNATION THAT CORRELATES WITH A RWL | | | DESIGNATION. (EXAMPLE RD-1 WITH RWL-1) | | | | | | 17B. SHT P2.33 NO SF SHOWN FOR AREA NEXT | | | TO 6"RD(1560SF). | | | | | | 18B. SHT P3.01 RECHECK ADDITION OF DFU'S | | | AS THEY ACCUMULATE IN THE SANT. SYSTEM. | | | TABLE 710.1(1). | | | | | | 19B. P3.01 LINE TO (A)(47FU), WHERE IS | | | THE CONTINUATION TO THIS LINE. PLEASE | | | CLARIFY. SECTION 106.1.1. | | | | | | 20B. SHT P3.01 TOILET ROOM ISOMETRIC, | | | PLEASE INDICATE WHICH RISER THE SANT. | | | BRANCH LINE CONNECTS TO. SECTION | | | 106.1.1. | | | | | | 21B. SHT P3.01 AAV FOR 2" STACK TO SINK | | | NOT APPROVED. SECTION 917.3. | | | | | | 22B. SHTS P3.03 & P3.04 CHECK RED LINE | | | CORRECTION FOR FIXTURE UNITS AT EACH | | | STACK INCICATED. FLOOR DRAINS OVER 2", | | | FIXTURE UNITS PER TABLE 709.2. | | | | | | 23B. P3.05 FUTURE WATER SUPPLY SHOWN AS | | | KEY NOTE #1, (6" WATER SERVICE) & SUB | | | METERS ARE SHOWN AS #2 (BACKFLOWS). | | | PLEASE CORRELATE KEY NOTES AND FLOOR | | | PLAN. SECTION 106.1.1. | | | | | | 24B. SHT P3.06 2 W/4 RISERS SHOWN, 2 | | | W/11 RISERS SHOWN, 2 W/8 RISERS SHOWN & | | | 2 W/28 RISERS SHOWN. PLEASE CORRELATE | | | RISER DIAGRAM WITH FLOOR PLAN.. | | | | | | 25B. SHT P3.06 3/4" WATER SUPPLY TO | | | URINAL IS CONNECTING TO 1/2" WATER | | | SUPPLY. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 26B. SHTS P3.12, P3.13, P3.14, & P3.15 | | | INDICATE RISER NUMBER FOR ALL "PAD" | | | RISERS, AND 5TH FLOOR DECK DRAIN/PLANTER | | | DRAIN RISERS TO BE ABLE TO TRACK RISERS | | | FROM THE BUILDING DRAIN THRU TO THE | | | DRAINS. SECTION 106.1.1. | | | | | | 27B. P3.12 CHECK ADDITION ON SF FOR SOME | | | RISERS. ALSO RWL/2 SF AT ROOF DRAIN | | | SHOWS (1866SF), BUT (1849SF) ON THE | | | RISER DIAGRAM. PLEASE CORRELATE. SECTION | | | 106.1.1. | | | | | | 28B. SHT P3.13 3" PAD (136SF) NOT | | | INDICATED ON DECK PLAN. PLEASE | | | CORRELATE. SECTION 106.1.1. | | | | | | 29B. SHT P3.14 6" REQUIRED AT SD | | | (1657SF). TABLE 1106.3 | | | | | | 30B. SHT P3.14 RISER DOES NOT REFLECT | | | THE FLOOR PLAN. PLEASE CORRELATE. | | | SECTION 106.1.1. | | | | | | 31B. SHT P3.14 RISER SHOWS 2 2ND FLOORS | | | AND 2 4TH FLOORS. PLEASE CLARIFY. | | | SECTION 106.1.1. | | | | | | 32B. SHT P3.14 CHECK ADDITION OF STORM | | | DRAIN PRIOR TO DRAINAGE WELL. TABLE | | | 1106.3. | | | | | | 33B. SHT P3.15 PAD RISER DOES NOT | | | REFLECT FLOOR PLAN AT THE MEZZ. LEVEL. | | | PLEASE CORRELATE. SECTION 106.1.1. | | | | | | 34B. THE FOLLOWING INFORMATION IS | | | REQUIRED FOR THE GAS PERMIT: | | | A. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | B. BTU LOAD OF EACH APPLIANCE AND THE | | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | | 402.4(33). (EACH SYSTEM). | | | C. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). (EACH | | | SYSTEM). | | | D. SUBMIT CALCULATIONS FOR COMBUSTION | | | AIR (IF APPLICABLE) PER FBC-2004 FUEL | | | GAS CODE SECTION 304. (EACH SYSTEM). | | | E. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION, SIZE AND TERMINATION OF THE | | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | | SECS. 502 THRU 505. (EACH SYSTEM). | | | F. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2004 FUEL GAS CODE SEC 402.2. (EACH | | | SYSTEM). | | | G. EMERGENCY HOOD SHUT DOWN SHUT OFF | | | VALVE TO BE BELOW CEILING. MANUAL SHUT | | | OFF VALVE TO BE UPSTREAM. UNION TO BE | | | DOWN STREAM OF MANUAL VALVE. (FOR | | | KITCHEN SYSTEM ONLY). | | | | | | 35B. THERE IS ONE SET OF "RED LINED" | | | PLANS. PLEASE RETURN THIS SET AND | | | COMMENT RESPONSES TO HELP EXPEDITE THE | | | NEXT PLAN REVIEW. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2005-12-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2005-12-05 |
Time |
16:57 |
Rev Time |
37.50 |
| Received By |
kstevens |
Date |
2005-12-01 |
Time |
19:08 |
Sent To |
|
|
| Notes |
| 2005-12-05 00:00:00 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FBC-2004 BUILDING | | | FHA-98 DESIGN MANUAL | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. IF THE DESIGN PROFESSIONAL IS AN | | | ARCHITECT OR ENGINEER LEGALLY REGISTERED | | | UNDER THE LAWS OF THIS STATE REGULATING | | | THE PRACTICE OF ARCHITECTURE AS PROVIDED | | | FOR IN CHAPTER 481, FLORIDA STATUTES, OR | | | ENGINEERING AS PROVIDED FOR IN CHAPTER | | | 471, FLORIDA STATUTES, THEN HE OR SHE | | | SHALL AFFIX HIS OR HER OFFICIAL SEAL, | | | SIGNATURE, AND DATE TO SAID DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA AS | | | REQUIRED BY FLORIDA STATUTE. SECTION | | | 106.1, FAC 61G15-23.002(2)/61G1-16.003 | | | AND FS 471.2055/481.025. | | | 2. SHT A1.0 MEN'S & WOMEN'S TOILET ROOMS | | | SHALL BE ACCESSIBLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTIONS | | | 11-4.16, 11-4.19, & 11-4.22 AND ALL | | | SUBSECTIONS. | | | 3. SHT A1.0 THE DRINKING FOUNTAIN SHALL | | | BE ACCESSIBLE. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTIONS 11-4.15 AND ALL | | | SUBSECTIONS AS WELL AS SECTION | | | 11-4.1.3(10)(A) PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING. | | | 4. SHT A1.2 MEN'S & WOMEN'S TOILET ROOMS | | | SHALL BE ACCESSIBLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTIONS | | | 11-4.16, 11-4.19, 11-4.21, 11-4.22 AND | | | ALL SUBSECTIONS. ALSO FOR THE BREAK ROOM | | | SINK, 11-4.24 AND ALL SUBSECTIONS. | | | 5. SHT A1.18 MEN'S AND WOMEN'S LOCKER | | | ROOMS TO BE ACCESSABLE. SUBMIT DETAILS | | | SHOWING COMPLIANCE WITH SECTION 11-4.16, | | | 11-4.18, 11-4.19, 11-4.21, & 11-4.22 AND | | | ALL SUBSECTIONS. | | | 6. SHT A1.21 MEN'S & WOMEN'S TOILET | | | ROOMS AND DRINKING FOUNTAIN SHALL BE | | | ACCESSIBLE. (SEE COMMENTS 2 AND 5). | | | 7. SHT A9.10 UNITS A5.2, A5 & A5.1 CLEAR | | | FLOOR SPACE FOR SHOWERS SHALL BE | | | PARALLEL TO THE FIXTURE AND FLUSH WITH | | | THE CONTROLS. PAGE 7.56 PARAGRAPH TWO. - | | | UNITS A5, & A5.1 INDICATE SIZE OF | | | OPENING FOR W/C'S. (MINIMUM 33" REQD.). | | | 8. SHT A9.11 UNITS A5A.2, A5A. & A5A.1 | | | CLEAR FLOOR SPACE FOR SHOWERS SHALL BE | | | PARALLEL TO THE FIXTURE AND FLUSH WITH | | | THE CONTROL WALL. PAGE 7.56. | | | 9. SHT A9.13 UNITS A7 & A7.1 CLEAR FLOOR | | | SPACE FOR SHOWERS SHALL BE PARALLEL TO | | | THE FIXTURE AND FLUSH WITH THE CONTROL | | | WALL. PAGE 7.56. | | | 10. UNITS B1D.2, & B1D.1 W/C IN MASTER | | | BATH SHALL BE 18" OFF THE WALL TO THE | | | CENTER OF THE FIXTURE. PLEASE SHOW ON | | | THE PLANS. PAGES 7.43 THRU 7.46. | | | 11. SHT A9.24 UNITS C1.1, C1.2, & C1 | | | OPENING FOR WATER CLOSET IN BATH #2 | | | SHALL BE MINIMUM 33" . PLEASE INDICATE | | | ON PLANS. PAGE 7.44 | | | 12. SHTS A9.2 THRU A9.24 ALL UNITS. | | | CLEAR FLOOR SPACE FOR THE WATER CLOSETS | | | SHALL BE APPLIED OR SUPERIMPOSED OVER A | | | PLAN PER PAGE 7.43 PARAGRAPH ONE. | | | 13. SHTS A9.2 THRU A9.24 PER PAGE 7.7 | | | MINIMUM CLEARANCES BETWEEN COUNTERS AND | | | ALL OPPOSING ELEMENTS IS 40". PLEASE | | | INDICATE ON THE PLANS THE MINIMUM | | | CLEARANCE FOR ALL KITCHENS. | | | 14. SHT P2.01 NO PIPING SHOWN TO 3 PAD'S | | | PLEASE CLARIFY. SECTION 106.1.1 - SHOW | | | ALL PIPE SIZES FOR ALL PIPE SYSTEMS ON | | | THE FLOOR PLAN. TABLES 710.1 & 1106.3. - | | | TRAPS REQUIRED ON THE DRAIN LINES FOR | | | THE FIRE DRAIN RISERS. SECTION 802.2. - | | | FITTINGS SHALL BE INSTALLED TO GUIDE | | | SEWAGE AND WASTE IN THE DIRECTION OF | | | FLOW. SECTION 706.3 (SEE CD & D LINES TO | | | THE LEFT OF THE MANHOLE. - INDICATE | | | WHERE SD LINE IS GOING AT COL. LINE 12 | | | BETWEEN COLS. P & Q. SECTION 106.1.1. | | | 15. SHT P2.02 RISERS 9 & 10 ARE | | | MISLABLED AT COL. LINE 6-E. SECTION | | | 106.1.1. - NO PIPING SHOWN TO 2 PAD'S. | | | SECTION 106.1.1. - SHOW ALL PIPE SIZING | | | FO U/G BUILDING SANT. , STORM, COND., | | | AND DRAIN PIPING. SECTION 106.1.1. | | | 16. SHT P2.03 SANT. PIPING NOT APPROVED | | | IN THE EGRESS STAIRWELL AT COL LINE 22-I | | | PER NFPA-101 SECTION 7.1.3.2.1(6). - 2" | | | DRAIN LINE TO THE RIGHT OF COL. LINE 28 | | | REQUIRES A VENT. SECTION 901.2.1. - | | | FOUNTAIN WATER SUPPLY REQUIRES BACKFLOW | | | PROTECTION PER SECTION 608.13. INDICATE | | | METHOD OF PROTECTION. - KEY NOTES 4 & 7 | | | NOT FOUND. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | 17. SHT P2.04 SANT. PIPING NOT ALLOWED | | | IN THE STAIRWELL PER NFPA-101 SECTION | | | 7.1.3.2.1(6). | | | 18. SHTS P2.16 & P2.17 KEY NOTE 2 | | | INDICATES, AND PLAN SHOWS RISER THRU | | | NEXT FLOOR, WHEN THEY SHOUD INDICATE | | | "TURN DOWN". PLEASE CLARIFY. SECTION | | | 106.1.1. | | | 19. SHTS P2.19 & P2.20 SUBMIT | | | CALCULATIONS FOR PRIMARY AND SECONDARY | | | STORM DRAINS. SHOW SQUARE FEET, 1/2 AREA | | | OF ALL VERTICAL WALLS INCLUDING | | | PARAPETS, AND AREA OF ROOFS DRAINING TO | | | DECK AREA FROM ABOVE IN THE CALCULATIONS | | | PER SECTIONS 1106 & 1107 WITH ALL | | | SUBSECITONS. - SHOW THE LOCATION OF ALL | | | SECONDARY DRAINS. | | | 20 SHTS P2.28, P2.29, & P2.30 ARE | | | SHOWING ALL 37 RWL'S. PREVIOUS LEVELS | | | SHOW JUST A FEW IF ANY RWL LOCATIONS. | | | PLEASE SHOW ALL RWL'S ON EACH LEVEL. | | | SECTION 106.1.1. | | | 21. SUBMIT A STORM DRAIN COLLECTION | | | ISOMETRIC RISER DIAGRAM. (SHT P3.13 | | | SHOWN ON THE INDEX PAGE WAS NOT | | | SUBMITTED). - SHOW ALL PIPE SIZES, | | | SQUARE FOOTAGE AS IT ACCUMULATES IN THE | | | SYSTEM & LOCATION OF EACH RWL RISER. | | | SECTION 106.1.1. - SUBMIT STORM RISER | | | DIAGRAMS SHOWING ALL PIPE SIZES, | | | OFFSETS, AND SQUARE FOOTAGE ECT. SECTION | | | 106.3.5.1.3(7)(13). | | | 22. SHT P3.01 RECALCULATE FU'S FOR RISER | | | 11 & DOWNSTREAM. (11 NOT ADDED IN FU'S.) | | | SECTION 106.1.1 & TABLE 710.1(1). - ALL | | | FIRE DRAIN LINES REQUIRE A TRAP PER | | | SECTION 802.2. - RISERS 49 & 55 APPEAR | | | TO RISE TO THE 7TH FLOOR. PLEASE CLARIFY | | | SECTION 106.1.1. - PARTIAL SANITARY | | | COLLECTION ISOMETRIC DOES NOT REFLECT | | | THE FLOOR PLAN UPSTREAM OF THE TRASH | | | ROOM FLOOR DRAIN, AND DOWNSTREAM OF THE | | | MOP SINK. PLEASE CORRELATE RISER AND | | | FLOOR PLAN. SECTION 106.1.1. | | | 23. SHT P3.02 2-WAY CLEANOUTS ARE | | | REQUIRED ON BOTH THE ENTRANCE AND EXIT | | | OF THE GREASE INTERCEPTOR PER UTILITY | | | STANDARDS. - FIXTURE UNIT VALUE NOT | | | SHOWN FOR 3 FURTURE STUB UPS. TABLE | | | 710.1(1). - 10" 2679FU REQUIRES 12" PIPE | | | OR SHALL BE SHOWN AS 1/8"FT THE ENTIRE | | | RUN. TABLE 710.1(1) AND SECTION 704.1. - | | | 10" 2689FU REQUIRES 12" PIPE OR SHALL BE | | | SHOWN AS 1/8"FT THE ENTIRE RUN. TABLE | | | 710.1(1) & SECTION 704.1. - 12" 4402FU | | | REQUIRES 15" PIPE OR SHALL BE SHOWN AS | | | 1/8"FT THE ENTIRE RUN. TABLE 710.1(1) & | | | SECTION 704.1. | | | 24. SHT P3.03 RISERS S/27, S/36, S/78, | | | S/94 & S/31, S/89, S/147, S/149 VENT | | | STACK REQUIRED PER TABLE 903.2 | | | 25. SHTS P3.05, P3.06, & P3.07 SHT PX | | | INDICATED ON EACH SHEET WAS NOT LOCATED. | | | PLEASE SUBMIT SHT PX. SECTION 106.1.1. | | | 26. SHT P3.08 KEY NOTES INFORMATION IS | | | REVERSED FROM RISERS. PLEASE CORRELATE | | | KEY NOTES AND RISERS. SECTION 106.1.1. | | | 27. SHT P3.10 WATER RISER FOR UNIT A3.1 | | | AND REV. A3.1 INDICATE 2 W/M'S. FLOOR | | | PLAN ONLY INDICATES ONE. PLEASE | | | CORRELATE FLOOR PLAN & RISER DIAGRAM. | | | SECTION 106.1.1. | | | 28. SHT P3.12 PAD RISER TO THE LEFT OF | | | LIFT STATION AND PIPING WHERE THE PIPING | | | SPLITS LEFT & RIGHT PRIOR TO THE LIFT | | | STATION DO NOT REFLECT THE FLOOR PLAN. | | | ALSO 6 RISERS SHOW 2 FOURTH FLOORS. | | | PLEASE CORRELATE RISERS & FLOOR PLANS. | | | SECTION 106.1.1. | | | 29. SHT P3.13 NOT SUBMITTED. (SHOWN ON | | | THE INDEX SHEET). | | | 30. SHT P3.14 6 STORM MANHOLES ARE SHOWN | | | ON THE GROUND FLOOR PLUMBING PLANS. | | | THESE ARE NOW REFERED TO AS STORM DRAIN | | | LIFT STATIONS, AND ONLY 4 ARE SHOWN. | | | PLEASE CORRELATE THE TERMINOLOGY AND | | | INDICATE WHERE THE OTHER LIFT STATIONS | | | ARE LOCATED. NONE OF THE RISERS DIAGRAMS | | | REFLECT THE FLOOR PLANS. - PLEASE NUMBER | | | OR PLACE A DESIGNATION ON THE LIFT | | | STATIONS BOTH ON THE RISER DIAGRAMS AND | | | THE FLOOR PLANS TO HELP EXPEDITE THE | | | PLAN REVIEW. - RISER (4" 2830SF) DOES | | | NOT APPEAR TO PICK UP ANY DRAINS. PLEASE | | | CLARIFY. - 2" DRAIN UPSTREAM OF 4" HD IS | | | SHOWN TO BE ON THE SANT. SYSTEM ON THE | | | FLOOR PLAN. PLEASE CLARIFY. SECTION | | | 106.1.1. | | | 31. SHT P3.15 FITTINGS SHALL BE | | | INSTALLED TO GUIDE SEWAGE AND WASTE IN | | | THE DIRECTION OF FLOW. SECTION 706.3. | | | SEE FITTING UPSTREAM OF MANHOLE (OR LIFT | | | STATION). - DOES NOT REFLECT THE FLOOR | | | PLAN. RISERS CD/37 & DR/37 NOT SHOWN ON | | | RISER DIAGRAM. | | | 32. DOMESTIC BOOSTER PUMPS, STORM LIFT | | | STATION PUMPS SHALL BE LISTED. PLEASE | | | SUBMIT MANUF. SPECIFICATION SHEETS FOR | | | EACH. SECTION 303. | | | 33. GREASE INTECEPTOR SHALL BE SIZED BY | | | THE ENVIRONMENTAL COMPLIANCE MANAGER. | | | PLEASE CONTACT LYNN MASSON (561) | | | 822-2271 OR BY FAX (561) 822-2279 OR BY | | | E-MAIL [email protected]. | | | 34. SHT P309 KEY NOTES 7 - A/C CLOSET IS | | | A PLENUM AND AS SUCH SHALL HAVE NO | | | COMBUSTABLE MATERIAL. PLEASE INDICATE | | | THE MATERIAL BEING USED FOR THE THERMAL | | | EXPANSION VALVE DRAIN, THE P&T RELIEF | | | VALVE DISCHARGE DRAIN, AND THE EMERGENCY | | | PAN DRAIN FOR THE WATER HEATER. | | | 35. PLANS SHOW A VENT IN THE WALL AND AN | | | OPEN 2" DRAIN IN THE PLENUM. MORE | | | INFORMATION IS REQUIRED. WILL THE ROOM | | | AS A PLENUM PULL THE AIR FROM THE 2" | | | OPEN DRAIN AND INTRODUCE THE HUMID, WARM | | | AIR INTO THE AIR CONDITIONED AIR OF THE | | | UNIT? IS THIS PRACTICE ACCEPTABLE TO THE | | | MECHNAICAL ENGINEER? - ALSO THE VENT | | | TERMINATION SHALL EITHER VENT THRU THE | | | ROOF OR TERMINATE ABOVE THE CEILING 6" | | | ABOVE THE INSULATION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 653-2692 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
15 |
Status |
P |
Date |
2008-09-09 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-09-09 |
Time |
08:34 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-09-09 |
Time |
08:34 |
Sent To |
|
|
| Notes |
| 2008-09-09 08:35:43 | ZONING REVIEW: PASS | | | | | | ** PLAN REVISIONS A0.8, A1.15, A1.16 | | | | | | **COMPACT CAR SPACES SHALL BE MARKED ON THE PAVEMENT AS | | | COMPACT OR SMALL SPACES | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
14 |
Status |
P |
Date |
2008-09-08 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-09-08 |
Time |
09:38 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-09-08 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2008-09-08 09:42:06 | ZONING REVIEW: PASSED | | | | | | NOTE: CAT PALMS AT GROUND FLOOR IN PLANTER BOXES SHOULD | | | BE COORDINATED AS PER DISCUSSION WITH CITY LANDSCAPE | | | PLANNER. | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
13 |
Status |
P |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-07-14 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-07-14 |
Time |
14:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
12 |
Status |
P |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-07-14 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-07-14 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2008-07-14 14:59:02 | ZONING REVIEW: PASSED | | | | | | ** LANDSCAPE DRAWINGS ONLY- L1,L2,L3 AND L4 | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
11 |
Status |
P |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-05-14 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-05-14 |
Time |
14:49 |
Sent To |
|
|
| Notes |
| 2008-05-14 14:50:05 | ZONING REVIEW: PASSED | | | | | | ** REVISED SHEET A4.5 | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
10 |
Status |
P |
Date |
2008-04-08 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-04-08 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-04-08 |
Time |
11:56 |
Sent To |
P |
|
| Notes |
| 2008-04-15 16:06:46 | LANDSCAPE REVISION |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
9 |
Status |
N |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-03-18 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-03-18 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2008-03-18 08:55:59 | ZONING REVIEW: NOT REQUIRED | | | | | | * REVISIONS TO INTERIOR WORK, SECTIONS, AND RCP | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
8 |
Status |
P |
Date |
2008-03-18 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-03-18 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-03-18 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2008-03-18 08:54:26 | ZONING REVIEW: PASSED | | | | | | * REVISIONS TO CLOCK TOWER | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
7 |
Status |
P |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-12-21 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-12-21 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2007-12-21 10:05:56 | ZONING REVIEW: PASSED | | | | | | * ARCH REV 22 - PLANS & ELEVATIONS | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-10-26 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-10-26 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2007-10-26 13:54:52 | ZONING REVIEW: PASSED | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
N |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-07-31 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-07-31 |
Time |
14:17 |
Sent To |
B |
|
| Notes |
| 2007-07-31 14:20:43 | ZONING REVIEW: NOT REQUIRED | | | | | | * GENERAL REVIEW OF SHOP DRAWING SUBMITTALS FOR | | | AWNINGS, SHUTTERS, POOL FENCE/GATE, CLOCK TOWER | | | LOUVERS, SITE FENCE, PROPERTY FENCE. | | | | | | * PLEASE CONFIRM SITE FENCING SHALL NOT EXCEED MAX | | | ALLOWED BY CODE | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-06-28 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-06-28 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-06-28 |
Time |
11:18 |
Sent To |
|
|
| Notes |
| 2007-06-28 11:19:34 | ZONING REVIEW: PASSED WITH PROVISO | | | | | | * PLEASE ADJUST REVISED DOOR AT COMMERICAL SPACE #15 SO | | | THAT IT DOES NOT SWING INTO THE 10'-0" SIDEWALK. THE | | | SIDEWALK MUST REMAIN CLEAR. | | | (SEE COMM. SPACES #12 AND #14 FOR EXAMPLES OF DOORS | | | THAT ARE INSET SO SWING DOES NOT IMPINGE UPON | | | SIDEWALK). | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2006-07-28 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2006-07-28 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2006-07-28 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2006-07-28 00:00:00 | TDR CERTIFICATES ADDED TO BUILDING | | | PERMIT SUBMITTAL PACKAGE FOR RECORD | | | ONLY. | | | MJF |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2006-05-18 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2006-05-18 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2006-05-16 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2006-05-18 00:00:00 | 1. PLEASE SUBMIT COPY OF TDR CERTIFICATE | | | WITH BUILDING PERMIT FOR REVIEW AGAIN | | | BLDG SQUARE FOOTAGES | | | 2. PROVIDE ELEVATION AND/OR | | | MANUFACTURERS INFO REGARDING OH DOOR | | | (#22) INTO "MAINTAINENCE" ROOM ALONG | | | IRIS (MATERIAL ETC). AREA WILL NOT BE | | | DIRECTLY ACCESSIBLE BY VEHICLES - IS | | | LARGE OVERHEAD DOOR NECESSARY? |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2005-11-14 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2005-11-14 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2005-10-21 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2005-11-14 00:00:00 | VERIFY LANDSCAPING MEETS REQ'S AFTER | | | COMPLIANCE WITH AFOREMENTIONED NOTES | | 2005-10-21 00:00:00 | SIDEWALKS MUST BE 10'-0" MINIMUM ALL | | | FRONTAGES. NORTH AND SOUTH FRONTAGES DO | | | NOT APPEAR TO BE IN COMPLIANCE. | | | | | | LOADING DOCK TO BE RELATED OFF EXTERIOR | | | OF BUILDING AND INCORPORATED IN-SITE PER | | | SEC 94-485. | | | |
|
|