Plan Review Details - Permit 05091226
Plan Review Stops For Permit 05091226
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-17 Cont ID  
Sent By mjacobs Date 2006-07-17 Time 08:22 Rev Time 0.00
Received By mjacobs Date 2006-07-17 Time 07:45 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2005-11-10 Cont ID  
Sent By mjacobs Date 2005-11-10 Time 15:16 Rev Time 1.50
Received By mjacobs Date 2005-11-10 Time 14:09 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2006-08-28 Cont ID  
Sent By btrobaug Date 2006-08-28 Time 06:59 Rev Time 0.75
Received By btrobaug Date 2006-08-28 Time 06:20 Sent To PC
Notes
2006-08-28 00:00:00 
  
 PROVISO
  
 THIS PERMIT IS BEING ISSUED TO
 FACILITATE THE START OF THIS
 PROJECT.PLEASE MAKE THE FOLLOWING
 CORRECTIONS FOR CODE COMPLIANCE AND
 RESUBMIT FOR REVIEW PRIOR TO ROUGH
 INSPECTION.
  
 THIS CORRECTION WAS ON THE PREVIOUS
 REVIEW.
  
  
 3} THE HEAT PUMP IS LISTED AS 230 WATTS
 ON A SINGLE POLE 60 AMP BREAKER. SEE
 310.16.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2006-08-16 Cont ID  
Sent By btrobaug Date 2006-08-16 Time 07:36 Rev Time 0.50
Received By btrobaug Date 2006-08-16 Time 06:58 Sent To PC
Notes
2006-08-16 00:00:00 
  
 NONCOMPLIANT
  
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} THE PERSON TAKING RESPONSIBILITY FOR
 THE DESIGN MUST PRINT AND SIGN THEIR
 NAME TO SAME PER 106.3.4.2.
  
 2} THE MANUFACTUREERS SPECIFICATIONS
 THAT WERE REQUESTED ON THE PREVIOUS
 REVIEW HAVE NOT BEEN SUBMITTED.
  
 3} THE HEAT PUMP IS LISTED AS 230 WATTS
 ON A SINGLE POLE 60 AMP BREAKER. SEE
 310.16.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-07-05 Cont ID  
Sent By btrobaug Date 2006-07-05 Time 11:57 Rev Time 0.33
Received By btrobaug Date 2006-07-05 Time 07:37 Sent To P
Notes
2006-07-05 00:00:00 
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 1} PLEASE PROVIDE A CALCULATION INCLUDI
 NG ALL ADDED LOADS IMPOSED,ALL EXISTING
 LOADS AND THE EXISTING OR PROPOSED SERVI
 CE SPECIFICATIONS PER 215.15.
  
 2} SUBMIT MANUFACTURERS SPECIFICATIONS
 FOR THE HEAT PUMP.
  
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2005-10-06 Cont ID  
Sent By btrobaug Date 2005-10-06 Time 12:30 Rev Time 0.33
Received By btrobaug Date 2005-10-06 Time 12:25 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2005-10-14 Cont ID  
Sent By jleech Date 2005-10-14 Time 15:00 Rev Time 0.00
Received By jleech Date 2005-10-14 Time 15:00 Sent To P
Notes
2005-10-14 00:00:00GAS PERMIT REQUIRED SUBMIT PLANS WITH
 APPLICATION.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2005-09-26 Cont ID  
Sent By dalvarez Date 2005-09-26 Time 11:35 Rev Time 0.15
Received By dalvarez Date 2005-09-26 Time 11:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-08-26 Cont ID  
Sent By adarroug Date 2006-08-26 Time 15:01 Rev Time 0.00
Received By adarroug Date 2006-08-26 Time 15:01 Sent To E
Notes
2006-08-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-08-03 Cont ID  
Sent By adarroug Date 2006-08-03 Time 15:46 Rev Time 0.00
Received By adarroug Date 2006-08-03 Time 15:46 Sent To E
Notes
2006-08-03 00:00:00TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-25 Cont ID  
Sent By adarroug Date 2006-06-25 Time 18:35 Rev Time 0.00
Received By adarroug Date 2006-06-25 Time 18:35 Sent To E
Notes
2006-06-25 00:00:00TO "E" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2005-10-05 Cont ID  
Sent By adarroug Date 2005-10-05 Time 16:42 Rev Time 0.00
Received By adarroug Date 2005-10-05 Time 16:42 Sent To E
Notes
2005-10-05 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2005-09-26 Cont ID  
Sent By adarroug Date 2005-09-26 Time 18:53 Rev Time 0.00
Received By adarroug Date 2005-09-26 Time 18:53 Sent To Z
Notes
2005-09-26 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-07-14 Cont ID  
Sent By jleech Date 2006-07-14 Time 11:28 Rev Time 0.00
Received By jleech Date 2006-07-14 Time 11:28 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2005-10-14 Cont ID  
Sent By jleech Date 2005-10-14 Time 15:11 Rev Time 0.50
Received By jleech Date 2005-10-14 Time 15:11 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2005-10-04 Cont ID  
Sent By mmclean Date 2005-10-04 Time 13:48 Rev Time 0.00
Received By mmclean Date 2005-10-04 Time 13:48 Sent To I
Notes
***NONE***