| Plan Review Stops For Permit 05090984 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2006-06-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-06-27 |
Time |
09:04 |
Rev Time |
0.66 |
| Received By |
alange |
Date |
2006-06-27 |
Time |
09:04 |
Sent To |
|
|
| Notes |
| 2006-06-27 00:00:00 | REVISION DENIED | | | | | | 1.REVISIONS TO ORIGONAL PERMIT SHALL | | | BE DESIGNED BY THE DESIGNER OF RECORD. | | | | | | 2.SHOW LOCATION OF BEDROOMS ON PLANS | | | SUBMITTED SO THAT EMERGENCY ESCAPE | | | RESCUE OPENING SIZES CAN BE VERIFIED. | | | | | | 3.SHOW SQUARE FOOTAGE AND ROOF SLOPE | | | OF EXISTING ROOF. | | | | | | 4.TRUSS DRAWINGS HAV NOT BEEN APPROVED | | | YET AND STILL NEED TO BE RESUBMITTED. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2006-05-31 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-31 |
Time |
14:31 |
Rev Time |
0.50 |
| Received By |
alange |
Date |
2006-05-31 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2006-05-31 00:00:00 | TRUSS DRAWING REVIEW DENIED: | | | | | | SEE ATTACH SECTIONS FROM THE FLORIDA | | | ADMINISTRATIVE CODE. | | | 61G15-23.001AND61G15-23.002 | | | | | | ORIGONAL SIGNED AND SEALED DOCUMENTS | | | WITH THE CORRECT SEALS REQUIRED | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2006-05-23 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2006-05-23 |
Time |
12:03 |
Rev Time |
0.33 |
| Received By |
alange |
Date |
2006-05-23 |
Time |
12:03 |
Sent To |
M |
|
| Notes |
| 2006-05-23 00:00:00 | DENIED | | | | | | ENGINEERS SEAL USED SHOULD READ | | | "LICENSED" NOT CERTIFICATE61G1-16.001 | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2005-12-27 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-12-27 |
Time |
07:49 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-12-23 |
Time |
16:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-05 |
Time |
07:09 |
Rev Time |
1.25 |
| Received By |
alange |
Date |
2005-10-04 |
Time |
16:39 |
Sent To |
Z |
|
| Notes |
| 2005-10-05 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | | SHALL BE RECORDED AT PALM BEACH COUNTY | | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | | BLANK FORMS ARE AVAILABLE FROM THIS | | | OFFICE. | | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | | 90 DAYS OF RECORDING. | | | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 3.BASED ON SBCCI BUILDING VALUATION | | | DATA THE PERMIT VALUATION HAS BEEN | | | REVISED TO | | | 76.96 PER SQ. FT. X 710 = $54,641.00 | | | ADDITIONAL PERMIT FEES ARE DUE. | | | | | | 4.SHOW SIZE AND LOCATION OF ATTIC | | | ACCESS.FBC 2309.7.1 | | | | | | 5.SUBMIT PRODUCT APPROVALS WITH | | | QUALITY ASSURANCE FOR THE FOLLOWING: | | | WINDOWS, EXTERIOR DOORS, IMPACT | | | PROTECTION, STRAPS AND TIE-DOWNS. | | | | | | 6.ALL PRODUCT APPROVALS SUBMITTED | | | SHALL HAVE THE FOLLOWING STATE PRODUCT | | | APPROVAL ATTACHED. | | | PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | ART LANGE | | | BUILDING PLANS EXAMINER | | | 805-6672 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-12-13 |
Time |
17:09 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-12-13 |
Time |
17:09 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2005-09-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-09-23 |
Time |
22:08 |
Rev Time |
0.45 |
| Received By |
jleahy |
Date |
2005-09-23 |
Time |
22:05 |
Sent To |
M |
|
| Notes |
| 2005-09-25 00:00:00 | THE TWO SMALL BATHROOMS NEED GFI OUTLETS | | | 210.8A1 | | | | | | MASTER BATH NEEDS ADDITIONAL GFI WITHIN | | | 3' OF THE SINKS BOTH SINKS 210.52D | | | | | | NEED AN OUTLET ON BACK OF HOUSE | | | 210.8A3, 210.52E | | | | | | OUTLET SPACING NOT TO CODE IN MASTER | | | BDROOM AND BDROOM TO THE LEFT | | | 210.52A1,2 | | | | | | OUTLETS IN BDROOMS TO BE ARC FAULT | | | PROTECTED210.12B | | | | | | NEED A PANEL SCHEDULE SHOWING BREAKER | | | SIZES AND WIRE SIZES PER CODE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-14 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-14 |
Time |
16:03 |
Sent To |
M |
|
| Notes |
| 2006-08-14 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2006-08-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-08-10 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-08-10 |
Time |
16:53 |
Sent To |
M |
|
| Notes |
| 2006-08-10 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2006-06-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-06-21 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-06-21 |
Time |
10:29 |
Sent To |
B |
|
| Notes |
| 2006-06-21 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2006-05-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-27 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-27 |
Time |
15:21 |
Sent To |
B |
|
| Notes |
| 2006-05-27 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2006-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-22 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-22 |
Time |
16:35 |
Sent To |
B |
|
| Notes |
| 2006-05-22 00:00:00 | TO "ALANGE" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2006-05-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2006-05-06 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2006-05-06 |
Time |
15:13 |
Sent To |
M |
|
| Notes |
| 2006-05-06 00:00:00 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2005-12-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2005-12-13 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2005-12-13 |
Time |
09:30 |
Sent To |
E |
|
| Notes |
| 2005-12-13 00:00:00 | TO "JLEAHY" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2005-10-05 |
|
|
Cont ID |
|
| Sent By |
alange |
Date |
2005-10-05 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
alange |
Date |
2005-09-22 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2005-09-22 00:00:00 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
8 |
Status |
P |
Date |
2007-01-02 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2007-01-02 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
pkrauss |
Date |
2007-01-02 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2007-01-02 11:04:12 | A/C PLANS FOR THE EXISITNG HOME SYSTEM #2 (MANUAL J | | | CALCS) |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
7 |
Status |
P |
Date |
2006-08-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-15 |
Time |
14:43 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-08-15 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2006-08-15 00:00:00 | REVISION TO MECH. PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-08-11 |
Time |
09:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2006-08-11 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2006-08-11 00:00:00 | *** DENIED *** | | | 1) MECHANICAL PLANS HAVE TO MUCH | | | ELECTRICAL PLAN DETAIL ON THEM AND ARE | | | DIFFICULT TO READ. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY. PER 2004 FBC 106.1.1 . | | | | | | 2) THE PLANS NEED TO BE SEALED BY THE | | | ENGINEER AS HIS NAME AND INFORMATION IS | | | IN THE TITLE BLOCK, PER FAC 61G15-23.002 | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2006-05-24 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-24 |
Time |
14:51 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2006-05-24 |
Time |
14:51 |
Sent To |
|
|
| Notes |
| 2006-05-24 00:00:00 | REVISION TO ENERGY CAL'S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2006-05-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2006-05-08 |
Time |
12:10 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2006-05-08 |
Time |
12:10 |
Sent To |
B |
|
| Notes |
| 2006-05-08 00:00:00 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED | | | BY OWNER/AGENT. | | | | | | 2) NEED TO SUBMIT 2 COPY'S OF ALL | | | PAPER-WORK. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2005-12-20 |
|
|
Cont ID |
|
| Sent By |
pkrauss |
Date |
2005-12-20 |
Time |
11:10 |
Rev Time |
0.40 |
| Received By |
pkrauss |
Date |
2005-12-20 |
Time |
11:10 |
Sent To |
B |
|
| Notes |
| 2005-12-20 00:00:00 | PROVISO: | | | 1.RETURN AIR SHALL BE EQUAL TO SUPPLY. | | | ALL SUPPLY AIR INTO THE MASTER SUITE IS | | | TO BE INCLUDED WHEN SIZING THE RETURN | | | AIR. | | | | | | 2.PLEASE PROVIDE AS BUILT DRAWINGS | | | PRIOR TO INSPECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | | CONTACT PATTY KRAUSS AT (561)805-6719. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2005-12-14 |
Time |
09:09 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2005-12-14 |
Time |
09:09 |
Sent To |
P |
|
| Notes |
| 2005-12-14 00:00:00 | *** DENIED *** | | | 1)NEED TWO COPYS OF ENERGY CALCULATIONS. | | | 2) ENERGY CALCULATIONS NEED TO BE | | | SIGNED. | | | 3) PLANS SHOW NO A/C DUCT WORK, AND NO | | | AIR HANDLER LOCATION. | | | 4) PLANS SHOOW TWO A/C CONDENSER UNITS, | | | PLEASE EXPLAIN WHY. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2005-09-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2005-09-25 |
Time |
22:23 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2005-09-27 |
Time |
08:11 |
Sent To |
P |
|
| Notes |
| 2005-09-27 00:00:00 | *** DENIED *** | | | 1) NO MECHANICAL PLANS SUBMITTED. | | | 2) NEED NOTICE OF COMMENCEMENT. | | | 3) NEED ENERGY CALCULATIONS. | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2005-12-14 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-12-14 |
Time |
13:51 |
Rev Time |
0.25 |
| Received By |
jleech |
Date |
2005-12-14 |
Time |
13:51 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2005-10-04 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2005-10-04 |
Time |
15:29 |
Rev Time |
0.33 |
| Received By |
jleech |
Date |
2005-10-04 |
Time |
15:29 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2005-10-06 |
|
|
Cont ID |
|
| Sent By |
mmclean |
Date |
2005-10-06 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
mmclean |
Date |
2005-10-06 |
Time |
15:33 |
Sent To |
|
|
| Notes |
|
|